You are on page 1of 1

CompPanel

Secondary
beam spacing

v1.6

Project Name
Sub title
Analysed by
Secondary Beam Mark
Primary Beam Mark

Primary beam
5238.35
tributary
width as
appropriate for
internal or edge
beam

Job1
Example
Designer
B1
PB1

internal PB

LOADING

InService Live (nominal)


Is Live Load Reducible?
Superimposed Dead Load
Slab thickness (total)
Ave ponding allowance
Faade load if Edge Beam

3
Y
1.25
120
0
2.5

Span/incremental defln limit


Span/total deflection limit
Inservice live load
serviceability load factors

300
250
0.7
0.4

DEFLECTION

kPa
kPa
mm
mm
kN/m

Short
Long

Secondary beam span


13,350 mm
Secondary beam spacing
2,400 mm
Secondary beam type
Non-typical primary beam tributary width.
Primary beam span
7,200 mm
Prim beam tributary width
4,500 mm
Primary beam type

edge PB
x1
x2

Non-Standard Detail used.

Primary
beam span

Steel Decking

CONCRETE

Grade
Density

BEAM CONFIGURATION

CompPanel v1.3

Adopt
Standard
Details

32
2,400

MPa
kg/m3

SECONDARY BEAM

Save
CompBeam

Vibration

Save

Loads

Open /
Save
Group

Print
Help

Secondary
beam span

About

CONNECTION LOCATIONS ON PRIMARY BEAM mm

x1 =
x2 =
x3 =
x4 =
x5 =
x6 =

2,400
4,800
0
0
0
0

x7 =
x8 =
x9 =
x10 =
x11 =
x12 =

0
0
0
0
0
0

Reset

PRIMARY BEAM

300PLUS
Gr 350
Analyse

Open

Overall:
Camber:
Connectors:
Strength:
Shear Conn:
Deflection:
Stress:

Pass
50 mm
34 Studs
69.8%
OK
92.2%
73.3%

300PLUS
Gr 350
Analyse

Save
CompBeam

Overall:
Camber:
Connectors:
Strength:
Shear Conn:
Deflection:
Stress:

Copyright 2012. OneSteel Manufacturing Pty Limited ABN 42 004 651 325

Pass
0 mm
34 Studs
43.8%
OK
65.0%
48.7%

9:15 AM 15/05/2015