You are on page 1of 3

Calculation of effective length

C/C distance
Clear distance
Clear distance
Slab no. ly(m)
lx (m)
ly(m)
lx (m)
ly(m)
lx (m)
2.965
2.639
S1
2.715
2.389
2.815
2.965
2.825
S2
2.715
2.575
2.815
4.137
3.387
S3
3.887
3.137
3.987
4.137
3.387
S4
3.887
3.137
3.987
2.965
2.64
S5
2.715
2.39
2.815

Slab no. Ly (m)


S1
S2
S3
S4
S5

Lx (m)
2.815
2.815
3.987
3.987
2.815

S1
S2
S3
S4
S5

2.485
2.671
3.233
3.233
2.486

Calculation of Bending Moment Co-efficinets


Edge
Overall
d taken
condidepth,
(mm)
D (mm)
tion

2.485 Case-4
2.671 Case-3
3.233 Case-4
3.233 Case-2
2.486 Case-3

0.125
0.125
0.125
0.125
0.125

The total design load of slab (w) =

Slab no.

+d

0.15
0.15
0.15
0.15
0.15

1.13
1.05
1.23
1.23
1.13

Calculation of required Steel


Calculated moments (kN-m)
Calculated area (mm2)
2.279
1.958
4.308
3.443
1.902

3.023
2.600
5.738
4.572
2.536

1.945
1.798
3.292
2.634
1.557

2.612
2.376
4.421
3.481
2.058

65.6
56
125.6
100
56

87.5
75
168.8
134
73

Effective distance
Ly(m)
Lx (m)
2.815
2.485
2.815
2.671
3.987
3.233
3.987
3.233
2.815
2.486

14.5485
0.15154688

Co-efficinets

0.041
0.0305
0.0458
0.0366
0.0342

0.0544
0.0405
0.061
0.0486
0.0456

0.035
0.028
0.035
0.028
0.028

For Interpolation
1.1
1.2
0.033
0.039
0.033
0.039

0.047
0.037
0.047
0.037
0.037

fy (MPa)

ulated area (mm )


2

56
52
95.4
76
44.7

75.4
69
129
102
60

fck (MPa)
b (mm)
d (mm)
Mu(kN-m)
Ast

Table for Ast


415
20
1000
100
2.11
4760.11 59.1671

nterpolation
1.12
0.0342
0.0342