You are on page 1of 6

CGAM Problem - Ideal Gas

Fuel
0.00000 lb/s

0.000 T2 ( R)
15.900 P2 (bar)

1400.00 T3 ( R)
0.000 P3 (bar)
0.0000

Air Feed
1 lb/s
536.67 T1 ( R)
1.013 P1 (bar)

Stack

0.000
W_AC_or_GT (kW)

2500
0.000

0.0000 lb/s
0.000 T7( R)
1.013 P7 (bar)

0.0000 lb/s
536.670 T8( R)
20.000 P8 (bar)

Preheat/Economizer
0.0000 BTU/s

Variables

Physical

Fair (lb/s) = 1
nAC = 0.87

Cp,a (BTU/lb-R) =

1.4
0.24

P2 (bar) = 15.9

Tref (R) =

536.67

CH4(BTU/lb) =

21500

T3 (R) = 1400

a =

Evaporator
0.0000

T4 (R) = 2500
nGT = NA
nPT = 0.89
Tpinch ( R) = 3
Tapproach ( R) = 27

g =

1.33

Cp,g (BTU/lb-R) =

0.28

h (874R, 20) =

BTU/lb

h (847 R, 20) =

BTU/lb

h (536 R,20) =

BTU/lb

v
l
l

Material and Energy Balances


Temperatures (Real)

Log_Mean_Temps

Pressures

T0 (R) = 536.67
T1 (R) = 536.67

P0 (bar) = 1.013
P1 (bar) = 1.013

T2 (R) =
T3 (R) =

TLMEcon (R) =

P2 (bar) = 15.900
P3 (bar) =

T4 (R) =

TLMEvap (R) =

P4 (bar) =

T5 (R) =

TLMAPH (R) =

P5 (bar) =

T6 (R) =

P6 (bar) =

T7p(R) =

P7p (bar) = N/A


P7 (bar) = 1.013

T7 (R) =
T8 (R) = 536.67
T8p (R) =
T9 (R) = 874

P8 (bar) = 20.000
P8p (bar) = 20.000
P9 (bar) = 20.000

Heat
QCC (BTU/s) = 0.000
QLoss (BTU/s) = 0.000

Work
W AC_Actual (BTU/s) =
W GT_Actual (BTU/s) =

Efficiency = #DIV/0!
Transferred QEvap (BTU/s) =

W PT_Actual (BTU/s) =

Transferred QEcon (BTU/s) =

W PT_Net (BTU/s) =
Power_Actual (kW) =
Total Cost ($/s)=

#DIV/0!

Heat Rate (BTU/kW-hr)


#DIV/0!

Gas (Air + Fuel)


0.0000 lb/s
0.000 T5 ( R)
0 P5 (bar)

0.000 W_PT_Net (kW)


T4 ( R)
P4 (bar)

0 (MW)

0.0000 lb/s
0.000 T6( R)
0 P6 (bar)

0.0000 lb/s
874.000 T9( R)
20.000 P9 (bar)
Evaporator
BTU/s

Units Conversion
3600 s = 1 hr
3.413 BTU/hr= W

3600
3.413

1000 W = kW

1000

blue

variable

plum

constant

teal

calculated

Air_Fuel_Steam

nCC =

0.98

Ffuel(lb/s) =
Fair + Ffuel (lb/s) =
Fsteam(lb/s) =
Fwater(lb/s) =

Work (SI units)


0.0000

(kW)

(kW)

(kW)

Economics
ZAC($) = 25858.33992
ZCC($) = #DIV/0!
ZGT($) = #DIV/0!

ZAPH($) =
ZHRSG($) =
Fuel($/s)=
CRF(%) =
N(hr) =
=
cf($/MBtu) =

#DIV/0!
#DIV/0!
0
18.20%
8000
1.06
4.2204

SI Cost Coefficients (not used here)


CRF(%) = 18.20%
N(hr) = 8000
= 1.06
cf($/MJ) = 0.004

C11($/(lb/s)) = 17.95
C12 = 0.9

C11($/(kg/s)) = 39.5
C12 = 0.9

C21($/(lb/s)) = 11.64
C22 = 0.995

C21($/(kg/s)) = 25.6
C22 = 0.995

C23(1/R)= 0.01
C24= 26.4

C23(1/K)= 0.018
C24= 26.4

C31($/(lb/s))= 212
C32= 0.92

C31($/(kg/s))= 266.3
C32= 0.92

C33(1/R)= 0.02
C34= 54.4

C33(1/K)= 0.036
C34= 54.4

C41($/(m1.2)= 2290
U(Btu/(s m2 R))= 9.478/1000
C51($/(Btu/(s R)0.8)= 6097.2

C41($/(m1.2)= 2290
U(kW/(m2K))= 18/1000
C51($/(kW/K)0.8)= 3650

C52($/(lb/s))= 5361.5
C53($/(lb/s)1.2)= 254.8

C52($/(kg/s))= 11820
C53($/(kg/s)1.2)= 658