Asme Ix Practice Questions: (Closed Book)
Asme Ix Practice Questions: (Closed Book)
2.
3.
B.
C.
5.
Non-essential variables
Essential variables
Ranges of 1 & 2 above
All of the above; see QW-200.1(b)
4.
1958
1992
1987
1962; see 3rd paragraph of QW-100.3
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
31
6.
7.
8.
Vertical
Flat & horizontal
Flat & overhead; see QW-461.9
Horizontal
10.
Manufacturer
Welder
Authorised Inspector; see QW-200.1(e)
Foreman
9.
Flat only
Flat and horizontal
Flat and vertical
None of the above; see QW-461.9
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
32
C.
D.
11.
12.
13.
Stud welds
Overhand welds
Fillet welds
See QW-303.1
All of the above
Tensile strength
Ductility
Notch toughness
D.
All of above
B.
14.
True
It is true, see QW-304 for the welder and QW-305
for the welding operator. The operator of SAW is
welding operator, he is not welder. SAW falls under
machine welding. See QW-492 also for the definition
of welding operator and machine welding.
False
3.5%
0.5%
5%
Correct answer is 5%, see QW-153.1(d). The
question should read weld interface instead of fusion
line, see the definition of weld interface.
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
33
D.
15.
D.
16.
C.
D.
D.
welder,
the
acceptance
ASME Section V
ASME Section IX
See QW-191
ASME Section VII
The referencing code
Essential variables
Nonessential variables
Supplementary essential variable when
required for notch toughness
All of the above
See QW-200.1(b)
19.
qualify
18.
1/16
3/32
1/8
Correct answer is 1/8 (3mm), see QW-163, for
procedure and performance qualification same
criteria is of 3mm. For corrosion resistant weld
overlay cladding, see last sentence of 2nd paragraph
of QW-163.
None of the above
17.
Nonessential variables
Essential variables
See last paragraph of QW-100.1
Results of Welder Qualification tests
Project description & NDE methods
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
34
A.
B.
C.
D.
20.
21.
B.
C.
D.
23.
Groove design
Post Weld Heat Treatment
PWHT is essential variable for all welding processes.
For SMAW see QW-253
Root spacing
Method of cleaning
22.
Inspector
Manufacturer or contractor
See 2nd paragraph of QW-202.2(b)
Welder
All of the above
PQR
WQR
WPS
WPQ
Welder/welding operator performance qualification
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
35
24.
If a welder qualified with the SMAW process on Jan. 1,1994 and last
welded with SMAW on March 15, 1994, would he still be qualified
on October 7, 1994?
A.
B.
25.
D.
26.
Without backing
With all base metals
With backing only
Double sided weld is considered the weld with
backing, see QW-402.4. Backing is essential variable
for welder/welding operator, see QW-416.
With P1 backing only
27.
Yes
See QW-322.1(a)(1), his qualification expiry date
was July 1,1994. Since he has welded once in this
period from Jan 1, 1994 to July 1, 1994 so his expiry
extended to next 6 months, now his expiry date is
Jan 1, 1995. So he can weld with requalification on
October 7, 1994.
No.
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
36
28.
C.
D.
29.
30.
D.
32.
Electrodes
Flux
Base metals
See 1st paragraph of QW-420
Joints
31.
8
Max to be welded
He is qualified for unlimited weld metal thickness
provided he was qualified with 3 layers as a
minimum. See QW-452.1(b)
1
AWS class
ASME specification
SFA
F number
See 1st paragraph of QW-431
P number
Welder I.D.
A number
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
37
D.
33.
For
welder
qualifications
with
the
SMAW
______________________ is an essential variable.
A.
B.
C.
D.
34.
C.
D.
P number
Unique identifier
See QW-301.3
Hood & gloves
Inspector
36.
process
35.
Yes
No
To weld 1 pipe, he must be qualified on a pipe 1 to
2.5, see QW-452.3.
Not enough information provided
Yes, provided pipe is carbon steel, P#1
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
38
37.
A welder has been tested in the 6-G position, using as E-7018 F-4
electrode, on 6 Sch 160 (0.718 nom) SA 106B pipe. Is this welder
qualified to weld a 2 300# ANSI schedule 80 bore flange to a 2
Schedule 80 SA 106 B nozzle neck?
A.
B.
C.
D.
38.
Yes
No
No unless he is qualified on a pipe from 1 to 2.5,
see QW-452.3
Not enough information provided
Yes, provided a backing strip is provided in the
2 weld.
C.
D.
Yes
No
Double sided weld is considered with backing,
backing is essential variable, so he cannot weld
unless he is requalified.
Not enough information provided
Yes, because backing is not an essential
variable for a welder
39.
40.
The
The
The
The
See
Inspector
A.I.
Shop Foreman
Manufacturer of Contractor
QW-103.1
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
39
41.
42.
43.
44.
45.
2
See QW-452.1(a)
4
6
3
What positions are necessary to qualify a welder for all position pipe
welding?
A.
B.
C.
D.
3G and 4G
2G and 5G
See QW-461.9
3G and 1G
4G and 5G
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
40
46.
47.
C.
D.
electrode
storage
ASME IX
ASME VIII
ASME B31.1
ASME II Part C
Right option is II-C
Yes
No
Not enough information given
Yes, if properly heat treated
Yes
No
Procedure (groove weld) can never be qualified using
NDE.
Not enough information given
Yes, provided bend tests are done
50.
welding
49.
has
48.
Section
A welder was qualified with a P-1 test coupon using SMAW E 7018
electrodes. May the welder weld P-4 material using E8028
electrodes with backing in production? (Assume the P-4 procedure
using E8028 electrodes has been qualified)
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
41
A.
B.
C.
D.
51.
52.
Yes
See QW-100.3
No, must be re-qualified
Is only applicable for 1965 pressure vessels
Cannot be used for new construction repairs
only
What are the various positions in which a welder may qualify for
plate groove welds?
A.
B.
C.
D.
53.
Yes
No
See QW-433
Not enough information provided
None of the above
1G
3G
4G
All of the above
See QW-461.3
You are reviewing a WPQ (QW-484) for a welder testing in the 6-G
position, on SA-53 grade B pipe (TS-60,000 psi). The test results
indicate the following:
No.1
No.2
No.1
No.2
54.
A.
Yes
B.
No
He is qualified.
A.
Not enough information given
B.
Tension test is acceptable but No.1 is
unacceptable
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
42
55.
56.
57.
E6010
E7018
E9028
All of the above
59.
F,H,OH
F,V,OH
See QW-461.9
V,OH,SP
H,V,OH
58.
The WPS
The PQR
The WPQ
All of the above
5G and 6G
See Note 1 to QW-452.1(a)
2G and 4F
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
43
C.
D.
60.
61.
B.
C.
D.
Essential variable
See QW-401.1
Non-essential variable
Supplementary essential variable
All of the above
63.
Porosity, underfill
Lack of penetration/fusion
See QW-194
Slag, overlap
Any of the above
62.
4G and 5G
None of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
44
64.
65.
When using Macro-examination of fillet weld tests, the weld and the
HAZ must not reveal cracks when magnified at:
A.
B.
C.
D.
66.
5X
2X
10X
See QW-196.1.1
No magnification is required visual
examination is required, only
67.
(circle one)
68.
The AI approves
The test data on a PQR is a record of what
occurred and should never be changed. Only
editorial information can be changed on a PQR.
See QW-200.2(c).
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
45
C.
D.
69.
70.
71.
Pass
Pass, see QW-163
Fail
72.
73.
Or
74.
75.
SMAW
procedure
qualification
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
is
a
46
A.
B.
C.
D.
76.
77.
Essential
Non-essential
See QW-253
Supplemental essential
None of the above
SAW
procedure
qualification
is
an
Essential
See QW-254
Non-Essential
Supplemental essential
None of the above
78.
79.
Essential
Non-essential
See QW-253
Supplemental essential
None of the above
80.
True
Or
False (circle one)
False, see QW-461.9
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
47
81.
82.
83.
True
Or
False (circle one)
True, see QW-251.2
84. A welder qualified to weld in the 2G position on pipe would have to
be qualified in which of the additional positions to qualify for all
position groove welding on pipe?
A.
B.
C.
D.
E.
85.
1G
2G
5G
See QW-461.9
6G
All of the above
The maximum preheat temperature decrease allowed without requalification of a GMAW groove weld procedure is:
500F
1000F
See QW-255 and QW-406.1
C.
1250F
D.
1500F
E.
None of the above
A welder is qualified to weld all thick nesses of material when:
A.
B.
86.
A.
B.
C.
The
The
See
The
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
48
D.
87.
88.
C.
D.
E.
3 months
6 months
See QW-322
9 months
12 months
As stated by the AI
90.
inch
1/8 inch
See QW-163
1/16 inch
3/16 inch
No defects are allowed
89.
E7015
E6011
E6010
E7024
All of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
49
92.
93.
Designer or architect
Designer or installer
Architect or installer
Installer or assembler
Assembler or designer
For
P-11
materials,
weld
grooves
for
thick
nesses
________________ shall be prepared by thermal processes, when
such processes are to be employed during fabrication.
A.
B.
C.
D.
E.
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
50
94.
95.
True
Or
False (circle one)
False.
96. Reduced-section tensile test specimens conforming to QW-462.1
(b) may be used on all thicknesses of pipe having an outside
diameter greater than:
A.
B.
C.
D.
E.
97.
98.
2 inches
21/2 inches
3 inches
See QW-151.2
31/2 inches
4 inches
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
51
C.
D.
99.
Two plate tensile test specimens have been tested and found to be
acceptable. The characteristics of each specimen are as follows:
Specimen 1: Width of 0.752; thickness of 0.875; ultimate tensile
value of 78.524 psi
Specimen 2: Width of 0.702; thickness of 0.852; ultimate tensile
value of 77,654 psi
What is the ultimate load for each specimen that was reported on
the laboratory report?
A.
B.
C.
D.
GMAW
SAW
PAW
All of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
52
ANSWER KEY
1. C
2. D
3. D
4. D
5. B
6. B
7. C
8. C
9. D
10.
11.
12.
13.
B
C
C
A
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
C
D
A
C
B
D
D
A
B
A
B
True
D
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
53
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
C
C
B
D
B
B
B
A
B
D
B
C
A
C
C
C
C
D
C
C
B
B
A
B
B
A
D
C
B
B
A
B
D
B
B
C
A
A
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.
98.
99.
C
False
B
False
Pass
True
False
False
False
B
A
True
A
True
False
True
False
True
C
B
C
B
B
E
E
D
D
A
D
False
C
D
A
A
D
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia