Table of Contents
Flanged Pipe and Fittings

Loose Flanges, FLANGE-TYTE Gaskets


and Flanged Fittings for Water or Other Liquids

Flanged Fittings Ductile iron


Water 90 and 45 Bend
Water 22-1/2 and 11-1/4 Bends
Water Tees and Crosses
Water Base Bends

8
8
9
10
14

Base Drilling Details

15

Flanged Fittings
Water Base Tees
Water Reducers

16
16
17

Manufacturers Standard Flanged Fittings


90 Long Radius Bends
Blind Flanges
Wye Branches
True Wyes
Side Outlet 90 Elbows and Side Outlet Tees

20
20
21
22
25
26

Miscellaneous Flanged Fittings


Flange and Flare
Flange and Flare 90 Bends Standard and Long Radius
Standard Sludge Shoes with Flange or Bell Ends

27
27
28
29

FLANGE-TYTE Gasket For 4" through


64" Flanged Pipe and Fittings

30

Assembling Flanged Pipe and Fittings


with FLANGE-TYTE Gaskets

31

Method of Designating Outlets of


Reducing Fittings in Specifications

32

Method of Designating Location of


Tapped Holes for Drains When Specified

33

Combination of Standard Fittings


That May be Used in Place of Special Fittings

34

Method of Reading Size of All Types


of Standard and Special Fittings

35

Products for Water, Waste Water


and Fire Protection

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

36

NOTE: If specifiers and users believe that corrosive


soils will be encountered where our products are to
be installed, please refer to ANSI/AWWA C105/A21.5
Polyethylene Encasement for Ductile Iron Pipe
Systems, for proper external protection procedures.

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P3

Flanged Pipe and Fittings for


Water and Other Liquids
Flanged pipe and fittings are typical components in rigid piping systems. Such systems are
particularly suited for above ground installation in the following: water filtration plants, sewage
disposal plants, wastewater treatment plants, pumping stations and industrial plants. U.S. Pipe
gives special attention to such installations through its Customer Service Department. The
underground use of the flanged joint is generally not recommended due to the rigidity of the
joint. Unequal settlement or other stressing of such piping may result in excessive strain on the
flanges or the pipe.

Flanged Pipe with Threaded Flanges


Flanged pipe are fabricated by threading plain end pipe, screwing threaded flange(s) on and
machine-tightening them. The bolt holes are aligned per ANSI/AWWA C115/A21.15. The plain
end and the flange are then faced to provide a smooth surface across the end of the pipe
and the face of the flange. Pipe barrels and flanges have a taper pipe thread (NPT) in
accordance with ANSI B1.20.1, with thread diameters adapted to Ductile Iron pipe standard
outside diameters. Threaded pipe and threaded flanges are individually fitted and the
flanges are not interchangeable.
Flanged pipe are furnished in the following maximum lengths:
Sizes 4"-42" 17'6"
Sizes 3", 48"-64" 19'6"

ANSI /AWWA Standards


ANSI/AWWA C115/A21.15 Flanged DuctileIron Pipe with Ductile-Iron or Gray-Iron
Threaded Flanges.
Threaded flanged pipe conform to the
requirements of ANSI/AWWA C115/A21.15.
ANSI/AWWA C151/A21.51 Ductile Iron Pipe,
Centrifugally Cast, for Water.
Ductile Iron pipe used for flanging are centrifugally cast in accordance with the requirements
of ANSI/AWWA C151/A21.51.
ANSI/AWWA C110/A21.10 Ductile-Iron and
Gray-Iron Fittings, 3" through 48" (76 mm
through 1,219 mm), For Water (3-through
48" sizes) and ANSI/AWWA C153/A21.53
Ductile-Iron Compact Fittings, For Water
Service (54" through 64" sizes).

Pipe for wastewater service may be furnished in accordance with ASTM 746 Standard
Specification for Ductile Iron Gravity Sewer Pipe. The minimum class thickness for Ductile Iron
flanged pipe to be threaded is class 53 for sizes up through 54" and pressure class 350 for 60"
and 64" sizes. Greater pipe wall thicknesses can be furnished if so ordered.

U.S. Pipes Flanged Fittings are produced of


Ductile Iron and conform to the applicable
requirements for Ductile Iron fittings specified
in ANSI/AWWA C110/A21.10

Flanges are the solid design and are Ductile Iron in conformance with the requirements of
ANSI/AWWA C110/A21.10.

ANSI/AWWA C116/A21.16 Protective FusionBonded Epoxy Coatings for the Interior and
Exterior Surfaces of Ductile-Iron and GrayIron Fittings for Water Supply Service.

Weights of flanged pipe shown are subject to a minus tolerance of not more than 10% for individual pieces. To obtain the weight of a short flanged pipe, calculate the pipe weight for the
length from face to face of the flanges and add the weight of two flanges.
The Foreword of ANSI/AWWA C115/A21.15 lists the required information and the options which if
desired must be specified on the purchase order for flanged pipe, such as size and finished length.
See the standard for more details.

Coating Systems
Unless otherwise specified, flanged pipe will be furnished with a standard thickness cementmortar lining with asphaltic coating inside and outside. Fittings are furnished coated or uncoated
in accordance with the purchasers requirements.

ANSI/AWWA C104/A21.4 Cement-Mortar


Lining for Ductile-Iron and Gray-Iron
Fittings for Water.
Coating system options include primer base
coat, fusion bonded epoxy coating inside and
outside in accordance with ANSI/AWWA
C116/A21.16. Cement-mortar lining with
asphaltic coating inside and outside in
accordance with ANSI/AWWA C104/A21.4.
NOTE: If a field-applied coating is required for
appearance or color coding over FBE coatings, the
smooth finish must be roughened to provide an
anchor pattern a light brush blast or roughening
by coarse sandpaper is recommended.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P4

Flanged Pipe and Fittings for


Water and Other Liquids (cont.)
Accessories
The gaskets and bolts to be used with flanged pipe and fittings should be selected by the purchaser with due consideration for the particular service and installation requirements. Flanged
joint accessories (bolts, nuts and gaskets) can be furnished by U.S. Pipe if so specified. Rubber
gaskets, 1/8" thick, or U.S. Pipe FLANGE-TYTE Gaskets (4" through 64"size) are recommended
for normal water or sewage service.

Flange Compatibility and Pressure Ratings


The flanges of C110/A21.10, C115/A21.15 and C153/A21.53 standards conform to the drilling
and facing of ANSI B16.1 Class 125 flanges. This B16.1 Class 125 designation leads some to
conclude that these AWWA flanges are only rated at 125 psi service which is not correct.
C110/A21.10 flanged fittings are rated for 350 psi operating pressure for 3" through 12" sizes,
250 psi operating pressure for 14" through 48" sizes and C153/A21.53 fittings are rated for 150
psi operating pressure for 54" through 64" sizes. These ratings are at ambient temperatures with
at least a 2:1 factor of safety. Special gaskets such as U.S. Pipes FLANGE-TYTE Gaskets are
required for operating pressures greater than 250 psi.
(Flanges of Ductile Iron pipe and fittings meeting the requirements of ANSI/AWWA C115/A21.15
or ANSI/AWWA C110/A21.10 cannot be joined with Class 250 ANSI B16.1 flanges.)

Special Service Requirements


When requesting prices for flanged piping for carrying chemical solutions, please furnish
complete information regarding the type of material to be conveyed, composition, concentration,
pH, pressure and temperature.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P5

EDITION

Ductile Iron Flanged Pipe With Threaded Flanges

SIZE
Inches

PRESSURE
RATING
psi

OUTSIDE
DIAMETER
Inches

MIN. WALL
THICKNESS
Inches

MAXIMUM LENGTH
Feet

Inches

WEIGHT Pounds
FLANGE

PIPE W/O FLANGES


Per Foot

PIPE W/ FLANGES**
Per Length

250

3.96

0.31

19'

6"

10.9

225

350 *

4.80

0.32

17'

6"

13

13.8

270

350 *

6.90

0.34

17'

6"

17

21.4

410

350 *

9.05

0.36

17'

6"

28

30.1

580

10

350 *

11.10

0.38

17'

6"

38

39.2

760

12

350 *

13.20

0.40

17'

6"

58

49.2

975

14

250

15.30

0.42

17'

6"

72

60.1

1195

16

250

17.40

0.43

17'

6"

90

70.1

1405

18

250

19.50

0.44

17'

6"

90

80.6

1590

20

250

21.60

0.45

17'

6"

115

91.5

1830

24

250

25.80

0.47

17'

6"

160

114.4

2325

30

250

32.00

0.51

17'

6"

240

154.4

3185

36

250

38.30

0.58

17'

6"

350

210.3

4380

42

250

44.50

0.65

17'

6"

500

274.0

5795

48

250

50.80

0.72

19'

6"

625

346.6

8010

54

150

57.56

0.81

19'

6"

670

441.9

9955

60

150

61.61

0.83

19'

6"

1035

485.0

11525

64

150

65.67

0.87

19'

6"

1510

542.0

13590

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
Special gaskets such as U.S. Pipe FLANGE-TYTE Gaskets are required for operating pressures greater than 250 psi.
* U.S. Pipe rates its 4"-24" pipe for 350 psi service with use of the FLANGE-TYTE Gasket.
** Sizes 4"-42" weights shown for nominal 17'6" lengths
3", 48"-64" weights shown for nominal 19'6" lengths
For bolt hole details see page 6.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P6

EDITION

Ductile Iron Flanged Pipe


With Threaded Flanges Flange Details

DIMENSIONS Inches
SIZE
Inches

OD

BC

BOLT HOLE
Diameter

BOLT
Diameter & Length

QTY. OF
BOLTS

7.50

6.00

.75 .12

3/4

5/8 x 2-1/2

9.00

7.50

.94 .12

3/4

5/8 x 3

11.00

9.50

1.00 .12

7/8

3/4 x 3-1/2

13.50

11.75

1.12 .12

7/8

3/4 x 3-1/2

10

16.00

14.25

1.19 .12

7/8 x 4

12

12

19.00

17.00

1.25 .12

7/8 x 4

12

14

21.00

18.75

1.38 .19

1-1/8

1 x 4-1/2

12

16

23.50

21.25

1.44 .19

1-1/8

1 x 4-1/2

16

18

25.00

22.75

1.56 .19

1-1/4

1-1/8 x 5

16

20

27.50

25.00

1.69 .19

1-1/4

1-1/8 x 5

20

24

32.00

29.50

1.88 .19

1-3/8

1-1/4 x 5-1/2

20

30

38.75

36.00

2.12 .25

1-3/8

1-1/4 x 6-1/2

28

36

46.00

42.75

2.38 .25

1-5/8

1-1/2 x 7

32

42

53.00

49.50

2.62 .25

1-5/8

1-1/2 x 7-1/2

36

48

59.50

56.00

2.75 .25

1-5/8

1-1/2 x 8

44

54

66.25

62.75

3.00 .25

1-3/4 x 8-1/2

44

60

73.00

69.25

3.12 .25

1-3/4 x 9

52

64

80.00

76.00

3.38 .25

1-3/4 x 9

52

FACING: Flanges are plain faced without projection or raised face and are furnished smooth or with shallow serrations.
BACK FACING: Flanges may be back or spot faced for compliance with flange thickness tolerances.
LAYING LENGTH DIMENSIONS: Pipe face-to-face dimensions conform to a tolerance of .12" for sizes 3"-64"
Fittings face-to-face dimensions conform to a tolerance of .06" for sizes 3"-10" and .12" for sizes 12"-64". The largest
opening governs the tolerance for all openings. Center-to-face tolerances are one half the face-to-face tolerances.
FLANGES: The bolt circle and bolt holes of these flanges match those of ANSI/AWWA C115/A21.15 and Class 125 flanges shown
in ANSI B16.1 and can be joined with A21.15 and Class 125 B16.1 flanges. The flanges do not match the Class 250 flanges
shown in ANSI B16.1 and cannot be joined with Class 250 B16.1 flanged fittings and valves.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P7

Loose Flanges
CAUTION: U.S. Pipe does not recommend the practice of assembling threaded flanges on
pipe in the field. As an accommodation to our customers, U.S. Pipe does provide flanged
pipe with unattached threaded flanges when specified. Certain precautions must be taken
when loose flanges are assembled to the pipe.
1. The threaded portion of the flange and the pipe are custom machined to accommodate the
exact diameter of the pipe. In addition, the pipe and flange have been faced in the shop
after proper tightening of the flange on the pipe. The unscrewed loose flange must be
mated only with the threaded pipe end on which it had been attached.
2. Extremely high torques are required to properly tighten screw flanges. If there is a question regarding the adequacy of the field tightening means,a trial assembly using grease
on the threads, should be made prior to making the final assembly. Because of the difficulty in tightening large flanges at the job sites, sizes larger than 16" should not be
attempted in the field.
3. The flange should never be final assembled on the pipe without the use of a lubricant or
sealant on the threads.
4. Prior to making the final assembly of the flange on the pipe, the threaded portion of the
flange and the pipe must be cleaned of all
foreign material such as dirt, sand or grit. A suitable solvent should
be used to remove any grease or oil remaining on the threads.
5. A two part 100% solids epoxy thread sealant should be applied to the threaded portion of
the pipe and flange using the sealant manufacturer's recommended procedure. If flanged
pipe will be in seawater,
it is recommended that the exposed threads be coated with Induron
PE-54 epoxy or wrapped with Denso tape which is available from:
Denso North America, Inc.
Houston, Texas
281-821-3355
6. The flange should be tightened until the face of the flange is at least flush with the faced
end of the pipe. Normally the flange can be screwed on the pipe by hand up to approximately the last three threads. Tightening the remaining threads creates the seal between
the pipe and the flange threads. If the face of the flange is not at least flush with the end
of the pipe, a proper seal between the threads will not be made. If the pipe protrudes
beyond the face,
it must be faced off smooth in a machine tool.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P8

FLANGE-TYTE Gaskets and


Flanged Fittings for Water or Other Liquids
U.S. Pipe FLANGE-TYTE Gaskets
U.S. Pipe FLANGE-TYTE Gaskets are available for 4" through 64" flanged pipe and flanged fittings having ANSI A21.15, ANSI/AWWA C110/A21.10or Class 125 ANSI B16.1 flanges. The
FLANGE-TYTE Gasket is a superior gasket suitable for use in a flanged joint for water working
pressures ofup to 350 psi*. The gaskets are 1/8" thick.
See FLANGE-TYTE Gasket details on pages 25 and 26.

Flanged Fittings for Water or Other Liquids


Flanged fittings shown on pages 8 to 25 meet all requirements of ANSI/AWWA C110/A21.10.
Flanges are plain faced without projection and furnished smooth or with shallow serrations.
Flanges may be back faced or spot faced for compliance with flange thickness tolerance. The
flange details are shown on page 6. The flanges are adequate for water service of 350 psi*
working pressure for 24" and smaller sizes and 250 psi for sizes through 48 and 150 psi for
the larger sizes. The bolt circle and bolt holes of these flanges match those of ANSI/AWWA
C115/A21.15 and Class 125 B16.1 flanges. The flanges do not match the Class 250 flanges
shown in ANSI B16.1 and cannot be joined with Class 250 B16.1 flanged fittings and valves.
When ordering flanged fittings equipped with bosses and/or tappedholes, refer to and specify
the letter key on page 29, which designates location by letter.
Special flanged fittings other than those shown on pages 8 through 29 may be available on
special order. Consult your nearest U.S. Pipe Sales Representative.
*U.S. Pipe rates its 4"-24" size flanged product at 350 psi with use of the FLANGE-TYTE
Gasket.
U.S. PIPE ASSUMES NO RESPONSIBILITY FOR FIELD ASSEMBLY PRACTICES AND DISCLAIMS ALL
LIABILITY ARISING THEREFROM.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P9

Flanged Fittings for Water 90 and 45 Bend Ductile Iron


Thicknesses, Dimensions and Weights

SIZE
Inches

PRESSURE
RATING
psi

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48
54
60
64

250
350*
350*
350*
350*
350*
350*
350*
350*
350*
350*
250
250
250
250
150
150
150

DIMENSIONS
Inches

WEIGHT
Pounds

90

45

.48
.52
.55
.60
.68
.75
.66
.70
.75
.80
.89
1.03
1.15
1.28
1.42
.90
.94
.99

5.5
6.5
8.0
9.0
11.0
12.0
14.0
15.0
16.5
18.0
22.0
25.0
28.0
31.0
34.0
39.0
43.0
48.0

4.0
4.5
6.0
7.0
9.0
10.0
11.5
12.5
14.0
15.5
18.5
21.5
24.5
27.5
30.5
35.42
33.34
35.29

3.0
4.0
5.0
5.5
6.5
7.5
7.5
8.0
8.5
9.5
11.0
15.0
18.0
21.0
24.0
20.5
23.5
25.0

3.62
4.81
7.25
8.44
10.88
13.25
12.06
13.25
14.50
16.88
18.12
27.75
35.00
42.45
49.50
41.05
45.48
47.78

90

45

25
45
65
105
165
235
290
370
450
580
900
1430
2135
3055
4095
3740
4965
6745

20
40
55
90
130
195
220
280
32
430
630
1120
1755
2600
3580
2735
3790
5105

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
For flange details see page 6.
Sizes 3"-48" conform to ANSI/AWWA C110/A2l.10. Sizes 54"-64" conform to ANSI/AWWA C153/A21.53.
*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 10

Flanged Fittings for Water 22-1/2 and 11-1/4 Bends


Ductile Iron Thicknesses, Dimensions and Weights

SIZE
Inches

PRESSURE
RATING
psi

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48
54
60

250
350*
350*
350*
350*
350*
350*
350*
350*
350*
350*
250
250
250
250
150
150

64

150

DIMENSIONS
Inches

WEIGHT
Pounds

22-1/2

11-1/4

.48
.52
.55
.60
.68
.75
.66
.70
.75
.80
.89
1.03
1.15
1.28
1.42
.90
.94
.99

3.0
4.0
5.0
5.5
6.5
7.5
7.5
8.0
8.5
9.5
11.0
15.0
18.0
21.0
24.0
14.0
14.0
13.5

7.56
10.06
15.06
17.62
22.62
27.62
25.12
27.62
30.19
35.19
37.69
57.81
72.88
88.00
103.06
32.42
39.41
41.68

3.0
4.0
5.0
5.5
6.5
7.5
7.5
8.0
8.5
9.5
11.0
15.0
18.0
21.0
24.0
12.0
10.5
9.5

15.25
20.31
30.50
35.50
45.69
55.81
50.75
55.81
60.94
71.06
76.12
116.75
147.25
177.69
208.12
30.81
44.07
43.56

22-1/2

11-1/4

20
40
55
90
135
205
225
285
335
435
640
1135
1790
2665
3665
2260
2985
3995

20
40
55
90
135
205
225
285
335
435
645
1150
1805
2680
3695
2100
2665
3585

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
For flange details see page 6.
Sizes 3"-48" conform to ANSI/AWWA C110/A2l.10. Sizes 54"-64" conform to ANSI/AWWA C153/A21.53.
*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 11

EDITION

Flanged Fittings for Water Tees and Crosses


Ductile Iron Thicknesses, Dimensions and Weights

RUN

SIZE
Inches
BRANCH

PRESS RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

T1

TEE

CROSS

250

.48

.48

5.5

5.5

40

50

250

.52

.48

6.5

6.5

60

70

350*

.52

.52

6.5

6.5

65

80

350*

.55

.48

8.0

8.0

85

95

350*

.55

.52

8.0

8.0

90

110

350*

.55

.55

8.0

8.0

95

120

350*

.60

.52

9.0

9.0

140

155

350*

.60

.55

9.0

9.0

145

165

350*

.60

.60

9.0

9.0

155

195

10

350*

.68

.52

11.0

11.0

205

220

10

350*

.68

.55

11.0

11.0

215

240

10

350*

.68

.60

11.0

11.0

225

265

10

10

350*

.80

.80

11.0

11.0

270

330

12

350*

.75

.52

12.0

12.0

290

310

12

350*

.75

.55

12.0

12.0

295

320

12

350*

.75

.60

12.0

12.0

310

345

12

10

350*

.87

.80

12.0

12.0

360

415

12

12

350*

.87

.87

12.0

12.0

385

460

14

350*

.66

.55

14.0

14.0

375

400

14

350*

.66

.60

14.0

14.0

390

425

14

10

350*

.66

.68

14.0

14.0

400

460

14

12

350*

.66

.75

14.0

14.0

425

505

14

14

350*

.66

.66

14.0

14.0

435

530

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 12

EDITION

Flanged Fittings for Water Tees and Crosses


Ductile Iron Thicknesses, Dimensions and Weights (cont.)
SIZE
Inches

PRESS RATING
psi

DIMENSIONS
Inches
H

WEIGHT
Pounds
J

TEE

CROSS

15.0

15.0

465

490

.60

15.0

15.0

475

520

.70

.68

15.0

15.0

495

555

350*

.70

.75

15.0

15.0

520

605

14

350*

.70

.66

15.0

15.0

530

620

16

16

350*

.70

.70

15.0

15.0

550

665

18

350*

.75

.55

13.0

15.5

480

505

18

350*

.75

.60

13.0

15.5

495

535

18

10

350*

.75

.68

13.0

15.5

510

560

18

12

350*

.75

.75

13.0

15.5

535

610

18

14

350*

.75

.66

16.5

16.5

630

720

18

16

350*

.75

.70

16.5

16.5

650

765

18

18

350*

.75

.75

16.5

16.5

665

795

20

350*

.80

.55

14.0

17.0

610

635

20

350*

.80

.60

14.0

17.0

620

665

20

10

350*

.80

.68

14.0

17.0

635

685

20

12

350*

.80

.75

14.0

17.0

660

735

20

14

350*

.80

.66

14.0

17.0

665

745

20

16

350*

.80

.70

18.0

18.0

810

915

20

18

350*

.80

.75

18.0

18.0

820

945

20

20

350*

.80

.80

18.0

18.0

855

1015

24

350*

.89

.55

15.0

19.0

845

875

24

350*

.89

.60

15.0

19.0

860

895

24

10

350*

.89

.68

15.0

19.0

880

930

24

12

350*

.89

.75

15.0

19.0

890

960

24

14

350*

.89

.66

15.0

19.0

900

975

24

16

350*

.89

.70

15.0

19.0

915

1010

24

18

350*

.89

.75

22.0

22.0

1220

1365

24

20

350*

.89

.80

22.0

22.0

1255

1430

24

24

350*

.89

.89

22.0

22.0

1330

1570

RUN

BRANCH

T1

16

350*

.70

.55

16

350*

.70

16

10

350*

16

12

16

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 13

EDITION

Flanged Fittings for Water Tees and Crosses


Ductile Iron Thicknesses, Dimensions and Weights (cont.)
SIZE
Inches

PRESS RATING
psi

RUN

BRANCH

30

12

30

DIMENSIONS
Inches

WEIGHT
Pounds

T1

TEE

CROSS

250

1.03

.75

18.0

23.0

1490

1565

14

250

1.03

.66

18.0

23.0

1490

1570

30

16

250

1.03

.70

18.0

23.0

1505

1605

30

18

250

1.03

.75

18.0

23.0

1515

1615

30

20

250

1.03

.80

18.0

23.0

1540

1670

30

24

250

1.03

.89

25.0

25.0

2025

2245

30

30

250

1.03

1.03

25.0

25.0

2150

2500

36

12

250

1.15

.75

20.0

26.0

2170

2240

36

14

250

1.15

.66

20.0

26.0

2175

2240

36

16

250

1.15

.70

20.0

26.0

2185

2270

36

18

250

1.15

.75

20.0

26.0

2190

2280

36

20

250

1.15

.80

20.0

26.0

2210

2325

36

24

250

1.15

.89

20.0

26.0

2255

2405

36

30

250

1.15

1.03

28.0

28.0

3000

3300

36

36

250

1.15

1.15

28.0

28.0

3160

3620

42

12

250

1.28

.75

23.0

30.0

3165

3240

42

14

250

1.28

.66

23.0

30.0

3170

3240

42

16

250

1.28

.70

23.0

30.0

3180

3270

42

18

250

1.28

.75

23.0

30.0

3185

3275

42

20

250

1.28

.80

23.0

30.0

3205

3320

42

24

250

1.28

.89

23.0

30.0

3245

3395

42

30

250

1.28

1.03

31.0

31.0

4125

4375

42

36

250

1.78

1.58

31.0

31.0

5360

5720

42

42

250

1.78

1.78

31.0

31.0

5580

6155

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 14

EDITION

Flanged Fittings for Water Tees and Crosses


Ductile Iron Thicknesses, Dimensions and Weights (cont.)
RUN

SIZE
Inches
BRANCH

PRESS RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

T1

TEE

CROSS

48

12

250

1.42

.75

26.0

34.0

4315

4390

48

14

250

1.42

.66

26.0

34.0

4315

4385

48

16

250

1.42

.70

26.0

34.0

4330

4415

48

18

250

1.42

.75

26.0

34.0

4330

4420

48

20

250

1.42

.80

26.0

34.0

4350

4460

48

24

250

1.42

.89

26.0

34.0

4385

4535

48

30

250

1.42

1.03

26.0

34.0

4455

4670

48

36

250

1.42

1.15

34.0

34.0

5555

5880

48

42

250

1.96

1.78

34.0

34.0

7195

7630

48

48

250

1.96

1.96

34.0

34.0

7385

8005

54

30

250

1.05

.72

31.0

37.0

4615

4800

54

36

250

1.05

.77

31.0

37.0

4695

4950

54

42

250

1.05

.88

39.0

39.0

5740

6210

54

48

250

1.05

.94

39.0

39.0

5850

6425

54

54

250

1.05

1.05

39.0

39.0

6025

6780

60

36

250

1.10

.77

33.0

42.0

6015

6330

60

42

250

1.10

.88

43.0

43.0

7380

7885

60

48

250

1.10

.94

43.0

43.0

7490

8105

60

54

250

1.10

1.05

43.0

43.0

7665

8450

60

60

250

1.10

1.10

43.0

43.0

8045

9220

64

36

250

1.16

.77

32.0

44.0

7320

7610

64

42

250

1.16

.88

48.0

45.0

9610

10085

64

48

250

1.16

.94

48.0

45.0

9710

10275

64

54

250

1.16

1.05

48.0

46.0

9915

10690

64

60

250

1.16

1.10

48.0

46.0

10285

11430

64

64

250

1.16

1.16

48.0

48.0

10995

12855

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 15

EDITION

Flanged Fittings for Water Base Bends


Ductile Iron Thicknesses, Dimensions and Weights

SIZE
Inches

PRESSURE
RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

S DIAMETER

BASE BEND

BASE ONLY

250

4.88

5.00

.56

.50

35

10

350*

5.50

6.00

.62

.50

55

10

350*

7.00

7.00

.69

.62

85

20

350*

8.38

9.00

.94

.88

145

40

10

350*

9.75

9.00

.94

.88

210

45

12

350*

11.25

11.00

1.00

1.00

300

65

14

350*

12.50

11.00

1.00

1.00

360

70

16

350*

13.75

11.00

1.00

1.00

445

75

18

350*

15.00

13.50

1.12

1.12

565

115

20

350*

16.00

13.50

1.12

1.12

700

120

24

350*

18.50

13.50

1.12

1.12

1030

130

30

250

23.00

16.00

1.19

1.15

1625

190

36

250

26.00

19.00

1.25

1.15

2385

250

42

250

30.00

23.50

1.44

1.28

3465

410

48

250

34.00

25.00

1.56

1.42

4610

515

54

150

38.00

27.50

1.69

1.55

4415

675

60

150

42.00

32.00

1.88

1.75

5950

985

64

150

44.00

38.75

2.12

1.75

8155

1410

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
For flange detail see page 6.
Dimension R is a finished dimension; unfinished bases will be 1/8" longer. For base drilling details see page 15. For other dimensions see page 7.
* U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 16

Base Drilling Details For Base Bends And Base Tees

SIZE FITTING
Inches

DIMENSIONS
Inches
BOLT
CIRCLE

BOLT HOLE
DIAMETER

NUMBER
OF BOLTS

3.38

5/8

4.75

3/4

5.50

3/4

7.50

3/4

10

7.50

3/4

12

9.50

7/8

14

9.50

7/8

16

9.50

7/8

18

11.75

7/8

20

11.75

7/8

24

11.75

7/8

30

14.25

36

17.00

42

21.25

1-1/8

48

21.75

1-1/4

54

25.00

1-1/4

60

29.50

1-3/8

64

36.00

1-3/8

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 17

EDITION

Flanged Fittings for Water Base Tees


Ductile Iron Thicknesses, Dimensions and Weights

SIZE
Inches

PRESSURE
RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

S DIAMETER

BASE BEND

BASE ONLY

250

4.88

5.00

.56

.50

45

350*

5.50

6.00

.62

.50

70

10

350*

7.00

7.00

.69

.62

110

15

350*

8.38

9.00

.94

.88

185

30

10

350*

9.75

9.00

.94

.88

300

30

12

350*

11.25

11.00

1.00

1.00

430

45

14

350*

12.50

11.00

1.00

1.00

485

50

16

350*

13.75

11.00

1.00

1.00

600

50

18

350*

15.00

13.50

1.12

1.12

740

75

20

350*

16.00

13.50

1.12

1.12

930

75

24

350*

18.50

13.50

1.12

1.12

1410

80

30

250

23.00

16.00

1.19

1.15

2270

120

36

250

26.00

19.00

1.25

1.15

3320

160

42

250

30.00

23.50

1.44

1.28

5850

270

48

250

34.00

25.00

1.56

1.42

7720

335

54

150

38.00

27.50

1.69

1.55

6465

440

60

150

42.00

32.00

1.88

1.75

8755

710

64

150

44.00

38.75

2.12

1.75

12045

1050

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
For flange details, see page 6.
Dimension "R" is a finished dimension; unfinished bases will be 1/8" longer. For base drilling details see page 15. For other dimensions see page 9.
* U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 18

EDITION

Flanged Fittings for Water Reducers


Ductile Iron Thicknesses, Dimensions and Weights

SIZE
Inches

PRESSURE RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

T1

250

.52

.48

30

250

.55

.48

40

350*

.55

.52

45

350*

.60

.52

11

65

350*

.60

.55

11

75

10

350*

.68

.52

12

85

10

350*

.68

.55

12

90

10

350*

.68

.60

12

110

12

350*

.75

.52

14

120

12

350*

.75

.55

14

130

12

350*

.75

.60

14

145

12

10

350*

.75

.68

14

170

14

350*

.66

.55

16

155

14

350*

.66

.60

16

175

14

10

350*

.66

.68

16

190

14

12

350*

.66

.75

16

220

16

350*

.70

.55

18

190

16

350*

.70

.60

18

210

16

10

350*

.70

.68

18

235

16

12

350*

.70

.75

18

265

16

14

350*

.70

.66

18

280

LARGE

SMALL

* U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 19

Flanged Fittings for Water Reducers


Ductile Iron Thicknesses, Dimensions and Weights (cont.)
SIZE
Inches

PRESSURE RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

T1

350*

.75

.60

19

240

10

350*

.75

.68

19

265

18

12

350*

.75

.75

19

295

18

14

350*

.75

.66

19

310

18

16

350*

.75

.70

19

340

20

10

350*

.80

.68

20

310

20

12

350*

.80

.75

20

345

20

14

350*

.80

.66

20

355

20

16

350*

.80

.70

20

390

20

18

350*

.80

.75

20

410

24

12

350*

.89

.75

24

480

24

14

350*

.89

.66

24

490

24

16

350*

.89

.70

24

525

24

18

350*

.89

.75

24

550

24

20

350*

.89

.80

24

590

30

18

250

1.03

.75

30

810

30

20

250

1.03

.80

30

870

30

24

250

1.03

.89

30

970

36

20

250

1.15

.80

36

1230

36

24

250

1.15

.89

36

1345

36

30

250

1.15

1.03

36

1555

42

24

250

1.28

.89

42

1820

42

30

250

1.28

1.03

42

2060

42

36

250

1.28

1.15

42

2345

LARGE

SMALL

18

18

* U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 20

Flanged Fittings for Water Reducers


Ductile Iron Thicknesses, Dimensions and Weights (cont.)
SIZE
Inches

PRESSURE RATING
psi

DIMENSIONS
Inches

WEIGHT
Pounds

LARGE

SMALL

T1

48

30

250

1.42

1.03

48

2625

48

36

250

1.42

1.15

48

2950

48

42

250

1.42

1.28

48

3320

54

30

150

.90

.61

32

1625

54

36

150

.90

.66

28

1680

54

42

150

.90

.76

25

1800

54

48

150

.90

.80

18

1695

60

36

150

.94

.66

32

2165

60

42

150

.94

.76

26

2190

60

48

150

.94

.80

20

2110

60

54

150

.94

.90

15

2055

64

36

150

.99

.66

35

2805

64

42

150

.99

.76

30

2870

64

48

150

.99

.80

25

2825

64

54

150

.99

.90

18

2695

64

60

150

.99

.94

17

2980

NOTE: Actual weights of fittings, sizes 54"-64" may exceed those shown.
Sizes 3"-48" conform to ANSI/AWWA C110/A21.10. Sizes 54"-64" conform to ANSI/AWWA C153/A21.53.
For flange details see page 6.
On reducers of certain end combinations the number of bolt holes on one flange have an odd number in one quadrant and the opposite flange has an even
number of holes in the same quadrant so that there are only four positions in which the reducers can be placed to properly assemble with the adjacent
piping. Please take particular note that flange reducers have the vertical centerline marked on the edge of the flange. If assembled with the centerline in the
vertical plane, the casting will properly assemble.
Eccentric reducers with the same dimensions and weights given for concentric reducers are available when specified on purchase order.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 21

Manufacturers Standard Flanged Fittings


90 Long Radius Bends Ductile Iron

90 BEND LONG RADIUS


B
WEIGHTS
Inches
Pounds

NOMINAL
SIZE
Inches

PRESSURE
RATING
psi

WALL
THICKNESS
Inches

250

3/8

7-3/4

28

350*

1/2

48

350*

9/16

11-1/2

85

350*

5/8

14

145

10

350*

3/4

16-1/2

230

12

350*

13/16

19

350

14

350*

7/8

21-1/2

470

16

350*

24

670

18

350*

1-1/16

26-1/2

840

20

350*

1-1/8

29

1080

24

350*

1-1/4

34

1640

Thicknesses and Dimensions Conforming to ANSI B16.1


For sizes larger than 24" contact nearest sales office.
For flange details see page 6.
* U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 22

EDITION

Manufacturers Standard Flanged Fittings


Blind Flanges Ductile Iron

DIMENSIONS
Inches
SIZE
Inches

PRESSURE RATING
psi

DIAMETER
OF FLANGE
O

THICKNESS
OF FLANGE
Q

WALL
THICKNESS
V

BLIND FLANGES
Pounds

250

7.50

.75

.69

350

*9.00

.94

.88

16

350

*11.00

1.00

.94

25

350

*13.50

1.12

1.06

42

10

350

*16.00

1.19

1.12

63

12

350

*19.00

1.25

1.19

85

14

350

*21.00

1.38

1.31

120

16

350

*23.50

1.44

1.38

145

18

350

*25.00

1.56

1.50

185

20

350

*27.50

1.69

1.62

245

24

350

*32.00

1.88

1.81

370

30

250

38.75

2.12

1.37

500

36

250

46.00

2.38

1.58

790

42

250

53.00

2.62

1.78

1175

48

250

59.50

2.75

1.96

1585

54

150

66.25

3.00

2.23

2260

60

150

73.00

3.12

2.68

2955

64

150

80.00

3.38

2.81

3855

NOTE: Actual weights of fittings, sizes 54"-64", may exceed those shown.
For bolt hole details see page 6.
*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
Flanges are faced and drilled in accordance with ANSI/AWWA C110/A21.10.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 23

Manufacturers Standard Flanged Fittings


Wye Branches Ductile Iron

SIZE
Inches

PRESSURE RATING
psi

DIMENSIONS
Inches
A

WALL THICKNESS

WEIGHT
Pounds
B

RUN

BRANCH

RUN

BRANCH

250

.48

.48

10

30

10

45

250

.52

.48

12

12

65

350*

.52

.52

12

12

75

350*

.55

.48

14.5

3.5

14.5

100

350*

.55

.52

14.5

3.5

14.5

105

350*

.55

.55

14.5

3.5

14.5

120

350*

.60

.52

17.5

4.5

17.5

165

350*

.60

.55

17.5

4.5

17.5

175

350*

.60

.60

17.5

4.5

17.5

200

10

350*

.68

.52

20.5

20.5

235

10

350*

.68

.55

20.5

20.5

250

10

350*

.68

.60

20.5

20.5

270

10

10

350*

.80

.80

20.5

20.5

335

12

350*

.75

.52

24.5

5.5

24.5

350

12

350*

.75

.55

24.5

5.5

24.5

365

12

350*

.75

.60

24.5

5.5

24.5

390

12

10

350*

.87

.80

24.5

5.5

24.5

470

12

12

350*

.87

.87

24.5

5.5

24.5

515

*U.S. Pipe rates its 4" - 24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 24

Manufacturers Standard Flanged Fittings


Wye Branches Ductile Iron (cont.)
SIZE
Inches

PRESSURE RATING
psi
WALL THICKNESS

RUN

BRANCH

14

14

DIMENSIONS
Inches
A

WEIGHT
Pounds
B

RUN

BRANCH

350*

.82

.55

27

27

475

350*

.82

.60

27

27

500

14

10

350*

.82

.68

27

27

525

14

12

350*

.82

.75

27

27

570

14

14

350*

.82

.82

27

27

605

16

350*

.89

.55

30

6.5

30

620

16

350*

.89

.60

30

6.5

30

645

16

10

350*

.89

.68

30

6.5

30

675

16

12

350*

.89

.75

30

6.5

30

715

16

14

350*

.89

.82

30

6.5

30

755

16

16

350*

.89

.89

30

6.5

30

805

18

350*

.96

.55

32

32

755

18

350*

.96

.60

32

32

780

18

10

350*

.96

.68

32

32

810

18

12

350*

.96

.75

32

32

850

18

14

350*

.96

.82

32

32

885

18

16

350*

.96

.89

32

32

935

18

18

350*

.96

.96

32

32

980

20

350*

1.03

.60

35

35

995

20

10

350*

1.03

.68

35

35

1025

20

12

350*

1.03

.75

35

35

1065

20

14

350*

1.03

.82

35

35

1110

20

16

350*

1.03

.89

35

35

1155

20

18

350*

1.03

.96

35

35

1200

20

20

350*

1.03

1.03

35

35

1265

*U.S. Pipe rates its 4" - 24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 25

Manufacturers Standard Flanged Fittings


Wye Branches Ductile Iron (cont.)
SIZE
Inches

PRESSURE RATING
psi
WALL THICKNESS

RUN

BRANCH

24

24

DIMENSIONS
Inches
A

WEIGHT
Pounds
B

RUN

BRANCH

350*

1.16

.60

40.5

40.5

1470

10

350*

1.16

.68

40.5

40.5

1505

24

12

350*

1.16

.75

40.5

40.5

1550

24

14

350*

1.16

.82

40.5

40.5

1590

24

16

350*

1.16

.89

40.5

40.5

1640

24

18

350*

1.16

.96

40.5

40.5

1685

24

20

350*

1.16

1.03

40.5

40.5

1750

24

24

350*

1.16

1.16

40.5

40.5

1905

30

12

250

1.37

.75

49

10

49

2545

30

14

250

1.37

.82

49

10

49

2590

30

16

250

1.37

.89

49

10

49

2645

30

18

250

1.37

.96

49

10

49

2690

30

20

250

1.37

1.03

49

10

49

2760

30

24

250

1.37

1.16

49

10

49

2915

30

30

250

1.37

1.37

49

10

49

3225

36

12

250

1.58

.75

60

19.5

60

4490

36

14

250

1.58

.82

60

19.5

60

4545

36

16

250

1.58

.89

60

19.5

60

4610

36

18

250

1.58

.96

60

19.5

60

4670

36

20

250

1.58

1.03

60

19.5

60

4750

36

24

250

1.58

1.16

60

19.5

60

4920

36

30

250

1.58

1.37

60

19.5

60

5255

36

36

250

1.58

1.58

60

19.5

60

5740

*U.S. Pipe rates its 4" - 24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
For flange details see page 6.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 26

Manufacturers Standard Flanged Fittings


True Wyes Ductile Iron

SIZE
Inches

PRESSURE RATING
psi

DIMENSION
Inches

WEIGHT
Pounds

WALL THICKNESS

250

3/8

5-1/2

30

350*

1/2

6-1/2

55

350*

9/16

3-1/2

85

350*

5/8

4-1/2

135

10

350*

3/4

11

210

12

350*

13/16

12

5-1/2

300

Thicknesses and Dimensions Conforming to ANSI B16.1


*U.S. Pipe rates its 4" - 24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
For flange details see page 6.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 27

EDITION

Manufacturers Standard Flanged Fittings


Side Outlet 90 Elbows and Side Outlet Tees

DIMENSIONS
Inches

WEIGHT
Pounds

SIZE
Inches

PRESSURE RATING
psi

WALL
THICKNESS

CENTER TO
FACE A

SIDE OUTLET
90 ELBOW

SIDE OUTLET
TEE

250

3/8

5 -1/2

34

48

350*

1/2

6-1/2

59

82

350*

9/16

96

135

350*

5/8

150

210

10

350*

3/4

11

240

330

12

350*

13/16

12

340

470

14

350*

7/8

14

470

650

16

350*

15

620

850

18

350*

1-1/16

16-1/2

760

1040

20

350*

1-1/8

18

970

1330

24

350*

1-1/4

22

1510

2080

Ductile Iron Thicknesses and Dimensions Conforming to ANSI B16.1


*U.S. Pipe rates its 4"-24" pipe and fittings for 350 psi service with use of the FLANGE-TYTE Gasket.
For flange details see page 6.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 28

Miscellaneous Flanged Fittings


Flange and Flare Ductile Iron

SIZE
Inches

WEIGHT
Pounds

.48

7.50

20

.52

9.00

30

.55

11.00

40

.60

13.50

10

70

10

.68

10

16.00

10

95

12

.75

12

19.00

12

155

14

.66

14

21.00

12

165

16

.70

16

23.50

16

240

18

.75

18

25.00

16

275

20

.80

20

27.50

18

355

24

.89

24

32.00

18

480

30

1.00

38.75

18

704

36

1.15

46.00

18

1245

36

1.15

46.00

24

1450

42

1.28

53.00

24

1534

48

1.42

59.50

24

1865

54

1.54

66.00

24

2300

For flange details see page 6.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 29

Miscellaneous Flanged Fittings


Flange and Flare 90 Bends Standard and Long Radius
Ductile Iron

DIMENSIONS
Inches
STANDARD

WEIGHT

DIMENSIONS
Inches

Pounds

SIZE

C
DIAMETER

WALL
T

5-1/2

11

7-1/2

3/8

6-1/2

12

12

10

WEIGHT

Pounds

LONG RADIUS
SIZE

30

7-3/4

13-3/4

35

1/2

45

14-1/2

50

11

9/16

75

11-1/2

15-1/2

90

14

13-1/2

5/8

120

14

19

155

11

17

16

3/4

195

10

16-1/2

22-1/2

250

12

12

18

19

13/16

275

12

19

25

375

14

14

20

21

7/8

380

14

21-1/2

27-1/2

500

16

15

21

23-1/2

515

16

24

30

715

18

16-1/2

22-1/2

25

1-1/16

640

18

26-1/2

32-1/2

900

20

18

24

27-1/2

1-1/8

800

20

29

35

1140

24

22

28

32

1-1/4

1240

24

34

40

1720

30

25

32

38-3/4

1-7/16

1970

30

41-1/2

48-1/2

2920

For flange details see page 6.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

P 30

EDITION

Miscellaneous Flanged Fittings


Standard Sludge Shoes with Flange or Bell Ends Ductile Iron

SIZE

DIMENSIONS
Inches
BOLT
CIRCLE
A

WEIGHT
Pounds
DIAMETER OF
HOLES
B

FLANGE END
SLUDGE SHOE

BELL END
SLUDGE SHOE

12

7/8

49

66

14

7/8

69

92

15-3/4

7/8

86

118

10

18

106

143

12

21

139

182

For bolt hole details see page 6.


For availability consult your local U.S. Pipe representative.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P 31

FLANGE-TYTE Gaskets For 4" through 64"


Flanged Pipe and Fittings
The FLANGE-TYTE Gasket is a superior ring gasket that can save money on installation and
maintenance costs. When properly assembled, the FLANGE-TYTE Gasket gives a completely leakfree flanged joint at a reasonable bolt torque, even at high internal operating pressures on
flanged pipe, fittings, valves and hydrants.
A flange piping system can be installed with FLANGE-TYTE Gaskets and operated safely at high
internal pressures and high velocities and still handle the ever-present threat of high surges
without fear of gasket leaks. The FLANGE-TYTE Gasket is listed by Underwriters Laboratories.
Flanged joints with FLANGE-TYTE Gaskets are approved by Factory Mutual.
Flanges must conform to ANSI/AWWA C115/A21.15 Flanged Ductile-Iron Pipe with Threaded
Flanges or ANSI/AWWA C110/A21.10 Ductile-Iron and Gray-Iron Fittings, 3" through 48", For Water.
Flanged joints sealed with FLANGE-TYTE Gaskets are rated by U.S. Pipe for 350 psi working pressure for the 4" through 24" sizes, 250 psi for the 36" through 48" sizes and 150 psi for the 54"
through 64" sizes, based on the performance requirements of ANSI/AWWA C111/A21.11 RubberGasket Joints for Ductile Iron Pressure Pipe and Fittings. These FLANGE-TYTE Gaskets qualify as
a specially designed gasket in accordance with ANSI/AWWA C111/A21.11 which recognizes
350 psi rating for 24" and smaller sizes. 30" and 36" gaskets are rated for 350 psi as a
manufacturers standard.
Factory Mutual and Underwriters Laboratories rate the 4" through 12" size range for 250 psi.
FLANGE-TYTE Gaskets are 1/8" thick and are available in SBR, EPDM, nitrile, fluorocarbon or
neoprene. The gaskets meet the material requirements of ANSI/AWWA C111/A21.11.

NOTE: The flanges used in the above tests


conform to the dimensional requirements of
ANSI/ASME B16.1 Class 125 Flanges as well
the above referenced flange standards

as

FLANGE-TYTE is a registered trademark of U.S.


Pipe and Foundry Company.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 32

Assembling Flanged Pipe and Fittings


with FLANGE-TYTE Gaskets
The FLANGE-TYTE Gasket for flanged pipe and fittings should be assembled using the same
general procedures and practices as for plain ring type flange gaskets. As with all flange
assemblies, the faces of the flanges must be free of sand, grit, grease or other foreign matter.

Horizontal Lines

Bolt Torque Requirements


Bolt torque required by water working
pressures are as follows:
SIZE

150

psi

WORKING
PRESSURE
250 psi

350

90

110

90

110

90

110

10

90

130

12

90

130

14

110

150

16

110

160

18

120

180

20

120

200

24

130

220

30

140

36

160

42

585

48

625

54

550

60

600

64

600

Inches

For larger diameters, it may be necessary to glue the FLANGE-TYTE Gasket to the face of one of
the flanges prior to aligning the flanges. For smaller diameter joints the gaskets can be dropped
into the joint as it is being assembled. Align the flanges and insert several bolts in the lower half
of the flanges. Drop the FLANGE-TYTE Gasket between the two flanges so that the gasket rests
on the lower bolts. Insert the remaining bolts and follow the tightening procedure below.

Vertical Lines
Center the FLANGE-TYTE Gasket on the lower flange before assembling the joint. The gasket can
also be glued to the face of the flange to keep the gasket from dislodging during the assembly.

Bolt Tightening Procedure


After alignment has been completed, insert the bolts and hand tighten the nuts. Keep the gap
between the flanges approximately uniform while tightening. Tighten the bolts to the required
torque in several steps, alternating from one side to the other.

psi

Torque Values are in ft-lb.


These torque values are appropriate for use
with FLANGE TYTE Gaskets. For correct
torque values on other gaskets, consult
the gasket supplier.
The FLANGE-TYTE gasket is 1/8" thick

NOTE: If specifiers and users believe that


corrosive soils will be encountered where our
products are to be installed, please refer to
ANSI/AWWA C105/A21.5, Polyethylene
Encasement for Ductile Iron Pipe Systems,
for proper external protection procedures.
U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P 33

Method of Designating Outlets


of Reducing Fittings in Specifications

NOTE: The largest opening establishes the


basic size of a reducing fitting. The
largest opening is named first, except for
bullhead tees which are reducing on both
runs and for double branch elbows where
both branches are reducing, the
outlet is the largest opening and named
last in both cases.
In designating the openings of reducing
fittings they should be read in the order
indicated by the sequence of the letters a,
b, c and d. In designating the outlets of
side outlet reducing fittings the side outlet
is named last and in the case of the cross
which is not shown the side outlet is
designated by the letter e. Fittings of the
configurations shown on this page that are
not covered on pages 8 through 25 may be
furnished on special order. Consult your
nearest U.S. Pipe representative.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P 34

Method of Designating Location of


Tapped Holes for Drains When Specified

NOTE: The above sketches show two


views of the same fitting and represent fittings with symmetrical
shapes, with the exception of the
side outlet elbow and the side outlet tee (straight sizes).
Pages 32 and 33 are extracted from
American National Standard CastIron Pipe Flanges and Flanged
Fittings (ANSI B16.1-1975), with the
permission of the publisher, The
American Society of Mechanical
Engineers, United Engineering
Center, 345 East 47th Street, New
York, N.Y. 10017. Fittings of the configurations shown on this page that
are not covered on pages 8 through
25 may be furnished on special
order. Consult your nearest U.S. Pipe
representative.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P 35

Combination of Standard Fittings


That May be Used in Place of Special Fittings

The illustrations in the SPECIAL columns on this page indicate typical fittings that are often required with a combination of bell, plain
end, and flange outlets. The laying dimensions of these fittings are not covered by any standard and they are therefore usually named
SPECIAL inasmuch as they are made to order to suit certain conditions in piping installations.
To the right of each SPECIAL fitting is shown a combination of Standard fittings that can be used to obtain the same outlet effects as
the Specials. The laying dimensions may not be interchangeable since the dimensions of the Standard fittings are fixed whereas the
Special can be made to a variety of desired lengths.
The use of Standard fittings wherever possible is always recommended as the most economical and such fittings can usually be shipped
out of stock. In sending inquiries for fittings of dimensions deviating from the Standard, state specifically the type of outlets wanted,
reading, sizes, etc., as shown on this page, and give exact dimension from the center line to outlet.

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

Certified to
ANSI/NSF 61

2005

EDITION

P 36

Method of Reading Size of All Types


of Standard and Special Fittings

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

REVISED 11.05

866.DIP.PIPE

FLANGED PIPE & FITTINGS


NSF

2005

Certified to
ANSI/NSF 61

EDITION

P 37

Products for Water, Wastewater and Fire Protection


Ductile Iron Pipe

SIZE RANGE

TYTON JOINT Pipe

4"-64" Ductile Iron

Mechanical Joint Pipe

4"-12" Ductile Iron

TR FLEX Pipe

4"-64" Ductile Iron

Flanged Pipe

3"-64" Ductile Iron

USIFLEX Boltless Flexible Joint Pipe


for Subaqueous Installations

4"-48" Ductile Iron

Restrained Joints
TR FLEX Pipe

4"-64" Ductile Iron

MJ FIELD LOK Gaskets

4"-24"

FIELD LOK 350 Gaskets

4"-24"

FIELD LOK Gasket

30" & 36"

TR FLEX GRIPPER Rings

4"-36" Ductile Iron

TR TELE FLEX Assemblies

4"-24" Ductile Iron

HP LOK Restrained Joint

30"-42"

Ductile Iron Fittings


TYTON Fittings

14"-64" Ductile Iron

TRIM TYTON Fittings

4"-12" Ductile Iron

TR FLEX Fittings and TR FLEX Telescoping Sleeves

4"-64" Ductile Iron

Mechanical Joint Fittings

3"-48" Ductile Iron

TRIM TYTE MJ Fittings

3"-48" Ductile Iron

Flanged Fittings

3"-64" Ductile Iron

XTRA FLEX Couplings

4"-24" Ductile Iron

Miscellaneous Products
PROTECTO 401 Lined Ductile Iron Pipe for
Domestic Sewage and Industrial Wastes

4"-64" Ductile Iron

FLANGE-TYTE Gaskets

4"-64"

Polymeric Linings

For all pipe sizes

Saddle Outlets

Various Ductile Iron

Welded Outlets

Various Ductile Iron

Polyethylene Encasement

4"-64"

U.S. PIPE AND FOUNDRY CO.

FLANGED PIPE AND FITTINGS BRO-013

Our products are manufactured in conformance


with National Standards so that our customers
may be assured of getting the performance and
longevity they expect. Use of accessories or
other appurtenances that do not comply with
recognized standards may jeopardize the
performance and longevity of the project.

REVISED 01.06

NSF

Certified to
ANSI/NSF 61

All U.S. Pipe brochures and/or products are


subject to change without further notice.

P.O. BOX 10406


BIRMINGHAM, AL 35202
866.DIP.PIPE (866.347.7473)
FAX: 205.254.7165