To assemble the penetrometer screw the handle to the penetration rods equipped with the conical
point.
During the test the operator must hold the penetrometer in a vertical position and control the rate of
penetration by steading his arms against his legs and at the same time applying pressure to the
penetrometer handle.
The conical point should penetrate in the soil at the rate of 13 mm/sec.
Calculate the penetration pressure qc dividing the load, recorded by the proving ring, by the cross
section (*) of the point and plot it against the depth of penetration.
Obtain the undrained shear strength Cu of the soil from the following relationship:

Cu =

qc - sv 0
Nq

sv0 = total geostatic pressure calculated at the depth of investigation.


Nq = 15 for normally consolidated soils
Nq = 20 for overconsolidated soils

REFERENCE
Penetration testing
Proceedings of the second European Symposium on penetration testing - ESCPT II Amsterdam
24-27 May 1982
(*) 28.6 mm section = 6.45 cm2

Italy
CONTROLS S.r.l.
6, Via Aosta
I-20063 Cernusco s/N. (MI) Italy
Tel. +39-0292184.1
Facsimile +39-0292103333
E-Mail: controls@controls.it
Web Site: www.controls.it

France
Controls S. r.l.
Zone Artisanale
68130 Walheim, FRANCE
tel. +33-03 89 402655
facsimile +33-03 89 402645
E-Mail: Controls@controls.fr

Mexico
Equipos de Ensaye Controls S.a. De C.V.
Rio Churubusco N. 27, Col. Portales
C.P. 03300, Mexico, D.F.
Tel. +52-55 56726186
Facsimile +52-55 55393229
E-Mail: controlsmexico@mexis.com

Spain
Equipos de Ensayo Controls S.a.
Poligono industrial arboledas
C/Sabina, Nave 5, Manzana D
45200 - Illescas (Toledo), ESPAA
Tel: +34-902 180843 (4 lineas)
Facsimile: +34-902 180846
E-Mail: controls@eecontrols.es
Web Site: www.eecontrols.es

United Kingdom
Controls Testing Equipment Ltd
Controls House
Icknield Way
Tring, Hertfordshire HP23 4JX - U.K.
Tel. +44-1442 828311
Facsimile +44-1442 828466
E-Mail: sales@controlstesting.co.uk
Web Site: www.controlstesting.co.uk

Wykeham Farrance LTD


Weston Road, Slough, SL1 4HW - U.K.
Tel. +44-1753 571241
Facsimile +44-1753 811313
E-Mail: sales@wfi.co.uk
Web Site: www.wfi.co.uk

You might also like