Tube Standard Triple Layer-H2OT-currently

supplying 58 mm diameter and


1800 mm long only.
Specification diameter 47*and 58 47* and 58
millimeter
Length millimeter 1500* 1800 1500* 1800
Outer diameter millimeter 47 58 47 58
Inner diameter millimeter 37 47 37 47
Weight Kg 1.3 2.2 1.3 2.2
Glass Thickness inner tube 1.6 1.6
millimeter
Glass Thickness outer tube 1.6 1.6
millimeter
Glass Material Borosilicate Glass 3.3 Borosilicate Glass 3.3
Coating material Aluminum-Aluminum Nitride- Aluminum Nitride-Stainless
Aluminum Steel-Copper
Coating Outer surface of inner tube Outer surface of inner tube
Deposition method DC reactive sputtering DC reactive sputtering
Absorption Ratio >91% >94 %
Reflection Ratio <7% <6%
Vacuum Degree 3.0 T2-3 Pa 8.0 T2-4 Pa
Thermal Expansion 3.3*10-6 per degree C 3.3*10-6 per degree C
Stagnation Parameter 220 m2 degree Celsius/KW 220 m2 degree Celsius/KW
Solar Radiance exposure for 4.6 MJ/M2 4.4 MJ/m2 3.9 MJ/m2 3.6 MJ/m2
obtaining a present water
temperature
Average heat loss coef 0.75 w/m2.0C 0.73 w/m2.0C 0.67 w/m2.0C 0.62 w/m2.0C
Max pressure 0.6 MPa 0.6 MPa
Minimum Temperature -35 C -40 C
Max Hail diameter <25 mm <25 mm
Max Temp of heat pipe 270 C 300 C (also faster to reach max
temp)
Useful surface area per tube 0.12255 0.12255
(Square meters)

*Smaller diameter, and shorter tubes are used in areas like Southern US and Mexico, where
there is too much heat