Punching Shear with Moment Transfer (ACI-318)

Interior Column
created by Hanif HANIF
hanif.hanif@gmx.com

Column dimension
b
h

=
=

250
1650

Slab properties
h
d
f'c

=
=

280
240

32

b1

490

b2

1890

opening

Ac
c
c'

=
=
=

1142400
245
245

J/c

2.5E+008

J/c'
f

2.5E+008

0.75

0.25

=
=

200
2.0E+008

=
=

950
950000

Ultimate Reactions at column


Mu
Vu

Vertical Component of PT force, Vp


transverse
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)

=
=
=
=
=
=
=
=
=
=
=

0
1395
100
100
129.5
0.2
6500
6500
5200
5200
5200

high point of tendon


low point of tendon
a (drape height)
vert. component of PT Force, VP1

=
=
=

165
45
120

0.00

longitudinal
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)
high point of tendon
low point of tendon
a (drape height)
vert. component of PT Force, VP2

=
=
=
=
=
=
=
=
=
=
=
=
=
=

0
1395
100
100
129.5
0.2
6500
6500
5200
5200
5200
145
65
80

0.00

vert. component of PT Force, VP

0.00

Shear stress with Transferred Moment


vu
=

1.038

Allowable shear stress due to Moment Transfer

=
0.721

Punching Shear with Moment Transfer (ACI-318)


h-edge column (Case C)
created by Hanif HANIF
hanif.hanif@gmx.com

Column dimension
b
h

=
=

450 mm
1400 mm

Slab properties
h
d
f'c

=
=

300 mm
260 mm

35 Mpa

b1

710 mm

b2

=
=

1530 mm
0 mm

opening
Ac
c
c'

=
=
=

767000 mm2
355 mm
355 mm

J/c

2.4E+008 mm3

J/c'
f

77387414 mm3

0.69

0.31

=
=

200 KNm
2.0E+008 Nmm

=
=

751 KN
751000 N

Ultimate Reactions at column


Mu
Vu

Vertical Component of PT force, Vp


transverse
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)

=
=
=
=
=
=
=
=
=
=
=

6 strands
1395 Mpa
100 MPa
100 mm2
129.5 KN/strand
0.2
8000 mm
0 mm
6400 mm
0 mm
3200 mm

high point of tendon


low point of tendon
a (drape height)
vert. component of PT Force, VP1

=
=
=
=

150 mm
53 mm
97 mm
188.42 KN

longitudinal
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)
high point of tendon
low point of tendon
a (drape height)
vert. component of PT Force, VP2

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

0.00 KN

vert. component of PT Force, VP

188.42 KN

0 strands
1395 Mpa
100 MPa
100 mm2
129.5 KN/strand
0.2
9000 mm
2000 mm
7200 mm
1600 mm
4400 mm
175 mm
45 mm
130 mm

Shear stress with Transferred Moment


vu1
=

0.989 Mpa

Allowable shear stress

0.754 Mpa

fpc

1.5 Mpa

0.34

punching shear stress capacity


vc

1.98 Mpa

=
=

0
1000 mm

shear reinforcement
Av/s
s
Av

0 mm2/m

increase the section

OK, shear reinf. Not req'd

he section

reinf. Not req'd

Punching Shear with Moment Transfer (ACI-318)


b-edge column (case A)
created by Hanif HANIF
hanif.hanif@gmx.com

Column dimension
b
h

=
=

700 mm
1400 mm

Slab properties
h
d
f'c

=
=

370 mm
320 mm

35 Mpa

b1

860 mm

b2

=
=

1720 mm
0 mm

opening
Ac
c
c'

=
=
=

1376000 mm2
215.00 mm
645.00 mm

J/c

5.2E+008 mm3

J/c'
f

5.2E+008 mm3

0.68

0.32

=
=

500 KNm
5.0E+008 Nmm

=
=

700 KN
700000 N

Ultimate Reactions at column


Mu
Vu

Vertical Component of PT force, Vp


transverse
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)

=
=
=
=
=
=
=
=
=
=
=

8 strands
1395 Mpa
100 MPa
100 mm2
129.5 KN/strand
0.2
8000 mm
8000 mm
6400 mm
6400 mm
6400 mm

high point of tendon


low point of tendon
a (drape height)
vert. component of PT Force, VP1

=
=
=
=

195 mm
45 mm
150 mm
194.25 KN

longitudinal
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)
high point of tendon
low point of tendon
a (drape height)
vert. component of PT Force, VP2

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

183.65 KN

vert. component of PT Force, VP

377.90 KN

6 strands
1395 Mpa
100 MPa
100 mm2
129.5 KN/strand
0.2
9000 mm
2000 mm
7200 mm
1600 mm
4400 mm
175 mm
45 mm
130 mm

Shear stress with Transferred Moment


vu1
=

0.543 Mpa

Allowable shear stress

0.754 Mpa

fpc

1.5 Mpa

0.31

punching shear stress capacity


vc

1.82 Mpa

=
=

0
1000 mm

shear reinforcement
Av/s
s
Av

0 mm2/m

OK

OK, shear reinf. Not req'd

reinf. Not req'd

Punching Shear with Moment Transfer (ACI-318)


corner column
created by Hanif HANIF
hanif.hanif@gmx.com

Column dimension
b
h

=
=

400 mm
1700 mm

Slab properties
h
d
f'c

=
=

230 mm
200 mm

35 Mpa

b1

500 mm

b2

=
=

1800 mm
0 mm

opening
Ac
c
c'

=
=
=

460000 mm2
54.35 mm
250.00 mm

J/c

1.3E+008 mm3

J/c'
f

16398374 mm3

0.74

0.26

=
=

182 KNm
1.8E+008 Nmm

=
=

444 KN
444000 N

Ultimate Reactions at column


Mu
Vu

Vertical Component of PT force, Vp


transverse
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)

=
=
=
=
=
=
=
=
=
=
=

8 strands
1395 Mpa
100 MPa
100 mm2
129.5 KN/strand
0.2
8000 mm
8000 mm
6400 mm
6400 mm
6400 mm

high point of tendon


low point of tendon
a (drape height)
vert. component of PT Force, VP1

=
=
=
=

195 mm
45 mm
150 mm
194.25 KN

longitudinal
No. strand
Jacking stress
Losses
strand area
Eff. Prestress force
inflection ratio
span-right
span-left
span-right w/ inflection
span-left w/ inflection
s (eff. Span length)
high point of tendon
low point of tendon
a (drape height)
vert. component of PT Force, VP2

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

183.65 KN

vert. component of PT Force, VP

377.90 KN

6 strands
1395 Mpa
100 MPa
100 mm2
129.5 KN/strand
0.2
9000 mm
2000 mm
7200 mm
1600 mm
4400 mm
175 mm
45 mm
130 mm

Shear stress with Transferred Moment


vu1
=

0.496 Mpa

Allowable shear stress

0.754 Mpa

fpc

1.5 Mpa

0.34

punching shear stress capacity


vc

1.96 Mpa

=
=

0
1000 mm

shear reinforcement
Av/s
s
Av

0 mm2/m

OK

OK, shear reinf. Not req'd

reinf. Not req'd

Column
No
1
2
3
4
5
6
7
8

b
mm
800
800
800
800
800
800
800
800

h
mm
800
800
800
800
800
800
800
800

Slab
d

f'c

f'c0.5

mm
260
260
260
260
260
260
260
260

mm
230
230
230
230
230
230
230
230

Mpa
35
35
35
35
35
35
35
35

Mpa
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8

40
40
40
40
40
40
40
40

Note
The formula on Eq. 11-34 of ACI 31
If it applicable for both wall and co
Therefore, the value of

However, on the table above, the v

The article of 21.3.3.8 is only appli


If it applicable for both wall and co


1
1
1
1
1
1
1
1

ACI 318 (PT) with As = 0.00075Ac


b0
fpc
p
opening
mm
0
0
0
0
0
0
0
0

mm
4120
4120
4120
3660
3890
4120
4120
4120

Mpa
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

0.31
0.31
0.31
0.33
0.32
0.31
0.31
0.31

Vp
KN
500.00
500.00
500.00
500.00
500.00
500.00
500.00
500.00

Vc
KN
4813.95
4813.95
4813.95
4332.29
4573.12
4813.95
4813.95
4813.95

on Eq. 11-34 of ACI 318 is applicable only for column


le for both wall and column, it is always written "support" instead of "column" on ACI
he value of p is only valid for column instead of wall

n the table above, the value of p is assumed as 1 (very conservative)

f 21.3.3.8 is only applicable for column instead of wall


le for both wall and column, it is always written "support" instead of "column" on ACI

0.4*Vc
KN
1926
1926
1926
1733
1829
1926
1926
1926

Applied Shear
Vu
KN
2000
954
1500
520
650
2000
600
2700

Location
typical-internal
typical-internal
typical-internal
typical-corner
typical-h-edge
roof-internal
roof-internal
roof-internal

Remark
0
OK
OK
OK
OK
0
OK
0