You are on page 1of 14

DESIGN OF TOP PRECAST SLAB SLAB

FLEXURAL REINFORCEMENT
Ultimate Bending Moment
Thickness of slab (D)

Mu

76.53
300

Clear Cover (c')

40

Reinforcement Dia

16

Effective Depth (d)

260

fck

40

fy

460

BOTTOM REINFORCEMENT
K= Mu/fcu x b x d2

0.028303

Lever Arm Z = 0.5+sqrt[0.25-(K/0.9)] X d


Z = 0.96d
Use limiting value Z = 0.95d
Area of reinforcement As = M/0.95xfyxZ

709.0116

Provide Reinforcement

16
(Ast Provided

Provide Main Reinforcement at Bottom (B/W) =

16

TOP REINFORCEMENT
Area of reinforcement As = 0.13 Ag

338

Provide Reinforcement

12
(Ast Provided

Provide Reinforcement at Bottom (B/W) =

12

CHECK FOR SHEAR


Ultimate Shear
Shear Stress

=
= Vu/b x d

189
(shear occur at d distance from end face)
0.726923
<
(As per Table 3.8 of BS 8110-1:1997)

SLAB SLAB

KNm
mm
mm
mm

N/mm2
N/mm2

(STAAD OUTPUT)

mm2/m
tor @

1340
>
tor @

150

c/c

mm2/m
0.13% Ag
150

OK
c/c

mm2/m
tor @

150

c/c

753.9822 mm2/m
tor @

150

c/c

KN
(STAAD OUTPUT)
distance from end face)
N/mm2

0.759054 N/mm2
3.8 of BS 8110-1:1997)

OK

LOAD COMB 101 1.35DL+1.5EP


LOAD COMB 102 1.35DL+1.35EP+1.5PL+1.5VL+1.5SL

LOAD COMB 201 1.0DL+1.0EP


LOAD COMB 202 1.0DL+1.0EP+1.0PL+1.0VL+1.0SL

DESIGN OF TOP ROOF SLAB


FLEXURAL REINFORCEMENT
Ultimate Bending Moment
Thickness of slab (D)

Mu

5.75
200

Clear Cover (c')

40

Reinforcement Dia

12

Effective Depth (d)

160

fck

40

fy

460

BOTTOM REINFORCEMENT
K= Mu/fcu x b x d2

0.005615

Lever Arm Z = 0.5+sqrt[0.25-(K/0.9)] X d


Z = 0.96d
Use limiting value Z = 0.95d
Area of reinforcement As = M/0.95xfyxZ

86.5651

Provide Reinforcement

12

(Min. Requirement as per Dubal Standard)


(Ast Provided

Provide Main Reinforcement at Bottom (B/W) =

12

TOP REINFORCEMENT
Area of reinforcement As = 0.13 Ag

208

Provide Reinforcement

12
(Ast Provided

Provide Reinforcement at Bottom (B/W) =

12

CHECK FOR SHEAR


Ultimate Shear
Shear Stress

=
= Vu/b x d

11.5
(shear occur at d distance from end face)
0.071875
<
(As per Table 3.8 of BS 8110-1:1997)

For 0.28% steel Tc = 0.52 Mpa

F SLAB

KNm
mm
mm
mm

N/mm2
N/mm2

mm2/m
tor @

200

c/c

nt as per Dubal Standard)


mm2/m
565
>
0.13% Ag
tor @

200

OK
c/c

mm2/m
tor @

200

c/c

565.4867 mm2/m
tor @

200

c/c

KN
(STAAD OUTPUT)
distance from end face)
N/mm2

0.52
N/mm2
3.8 of BS 8110-1:1997)

OK

DESIGN OF UPPER GROUND FLOOR SLAB


FLEXURAL REINFORCEMENT
Ultimate Bending Moment
Thickness of slab (D)

Mu

57
250

Clear Cover (c')

40

Reinforcement Dia

12

Effective Depth (d)

210

fck

40

fy

460

BOTTOM REINFORCEMENT
K= Mu/fcu x b x d2

0.032313

Lever Arm Z = 0.5+sqrt[0.25-(K/0.9)] X d


Z = 0.96d
Use limiting value Z = 0.95d
Area of reinforcement As = M/0.95xfyxZ

653.8084

Provide Reinforcement

12

(Min. Requirement as per Dubal Standard)


(Ast Provided

Provide Main Reinforcement at Bottom (B/W) =

12

TOP REINFORCEMENT
Area of reinforcement As = 0.13 Ag

273

Provide Reinforcement

12
(Ast Provided

Provide Reinforcement at Bottom (B/W) =

12

CHECK FOR SHEAR


Ultimate Shear
Shear Stress

=
= Vu/b x d

53.46
(shear occur at d distance from end face)
0.254571
<
(As per Table 3.8 of BS 8110-1:1997)

For 0.35% steel Tc = 0.47 Mpa

FLOOR SLAB

KNm
mm
mm
mm

N/mm2
N/mm2

mm2/m
tor @

150

c/c

nt as per Dubal Standard)


mm2/m
754
>
0.13% Ag
tor @

150

OK
c/c

mm2/m
tor @

150

c/c

753.9822 mm2/m
tor @

150

c/c

KN
(STAAD OUTPUT)
distance from end face)
N/mm2

0.47
N/mm2
3.8 of BS 8110-1:1997)

OK