Instruction Manual For KO No1 Oca Vacuum Lamination Machine High Precision LCD Repair Machine Max 7 Inch
Instruction Manual For KO No1 Oca Vacuum Lamination Machine High Precision LCD Repair Machine Max 7 Inch
Users Book
1.Safety Regulations
For your safety, please read this handbook carefully to be more
familiar with the application and limitations of the machines and the
related potential risks.
2.Parameters
Power: AC220V 1500W
Selective:AC110VAC220V
Operation Air Pressure:00.2Mpa
Work Environment: 20-30, clean and dust-free
Laminating: Flat Type Lamination
Production Efficiency: 2~4min/1pcs
Heating Method: Constant temperature
Applicable Size: Below 7
Size of Equipment: 320*310*420mm
Height of Equipment: About 32kg
3.Features
*No Modules Needed, No Debubbling Process Needed;
*Press to Boot, Easy Operation
*Smart Constant Pressure; Automatic Shift to the Lamination and
Debubbling Mode
3.Module Alignment
5.Operation Process
Screen-Pressing Process
5.1 Check that whether the power and air source is normal or not and
whether the vacuum pump power and pipe are connected to the
equipment;
5.2 Switch on the power and press the button to boot the equipment
to check that whether the equipment can operate normally or not;
5.3Put the LCD with the OCA glue on the cut silicone (please stagger
the silicone away from the IC position of the flat cable);
5.4 Open the gate and put the tray on the cabinet;
5.5 Close the cabinet gate;
5.6 Press button to boot the equipment;
5.7 Wait patiently for 2 to 6 minutes;
5.8 Wait until the two indicator lights off or the vacuum table turns to
the minimal value. Open the cabinet gate and take out the product;
5.9 The process completed, check whether the product is normal or
not.
6.Debubbling Process
Note: when coating the OCA glue, the bubbles may be too large in
some cases, which results in the bubbles existing after lamination.
Please follow the following methods to debubble.
6.1 Please place the laminated assembly on the foam (please make
sure that the foam stagger from the IC of flat cable, as illustrated)
6.2 Open the gate and place the tray with products on the cabinet
6.3 Close the gate
6.4 Press the Button to put down the equipment
6.5 Predict the duration based on the exact situation
6.6Again press to put down the machine
Maintenance
Projects
Formwork
Items
Check that whether there are
some foreign matters. If positive,
please clean them
Vacuum Pump
Change
the
oil
months if necessary
every
three
Vacuum Degree
(m)
(-Mpa)
mmHg
0.1013
760
200
0.0990
742.7
400
0.0968
726.2
500
0.0957
717.9
1000
0.0902
676.7
1500
0.0846
634.7
2000
0.0790
593.3
1.2 Under the pressure setting status, [P_1] and the Set Value will be displayed
alternatively on the screen
Note: [P_1] will be shown in the delayed-type constantly-open output mode.
[m_1] will appear in the delayed-type constantly-closed output mode. (P1L,P1H)
will appear in the comparative-type constantly-open output mode. (n1L,n1H.)
will appear in the comparative-type constantly-closed output mode.
or
will flash.
If the highest digit flashes, press set, the lowest digit will flash.
1.4Hold the SET for over one second, return to the set value display mode
0 action is needed (no need for operation) to display the present and
reference values.
Comparative Output 1
Output setting
Comparative 2 Output
setting
NO/NC Switch
2.5/5/10/25/50/100/250/500/1,000/5,0
00ms
Response Time Setting
Unit Switch
4Return to Zero
The pressure hole will forcefully
return the pressure to zero in the
atmospheric conditions
Long press