You are on page 1of 14

PM counters

long
noNotification
nonPersistent
readOnly

pmNoOfDiscardedMsg
Monitors the number of messages that are discarded due to
congestion control on the control plane over Iub owing to UNI
SAAL or SCTP Congestion Control.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped every time a message is discarded.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmTotalTimeiubLinkCongestedUl
The time that the Iub link is congested for the NBAP Common
part of the control plane in the uplink direction.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: The actual measurement is started when the MO
NbapCommon is created. The counter is stepped once per
second from when a congestion is detected until the congestion
is ceased or NBAP Common communication is lost.
Unit: 1 s
Undefined value: -1

PM counters
long
noNotification
nonPersistent
readOnly

pmNoOfDiscardedMsg
Monitors the number of messages that are discarded due to
congestion control on the control plane over Iub owing to UNI
SAAL or SCTP Congestion Control.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped every time a message is discarded.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmTotalTimeiubLinkCongestedUl
The time that the Iub link is congested for the NBAP Common
part of the control plane in the uplink direction.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: The actual measurement is started when the MO
NbapCommon is created. The counter is stepped once per
second from when a congestion is detected until the congestion
is ceased or NBAP Common communication is lost.
Unit: 1 s
Undefined value: -1

long
noNotification
nonPersistent
readOnly

long
noNotification
nonPersistent
readOnly

pmDchFramesReceived
The number of received DCH Iub frames in kframes
(1000 frames).
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least
one DBCH device set. That is, state is operational and
the device board has correct capability.
Undefined value: -1
pmDchFramesTooLate
The number of DCH Iub FP frames discarded owing to
too late arrival, that is, after LTOA.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least
one DBCH device set. That is, state is operational and
the device board has correct capability.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmEdchiubLimitingRatio
Indicates in what degree the EUL traffic in uplink is
limited by the Iub/Iur interfaces, between RBS and
SRNC. When a high value is indicated, it should be
considered to extend Iub/Iur with higher EUL
bandwidth.
Indicates the percentage of 100 ms periods with
scheduled EUL traffic where Iub has been the only
limiting factor during at least one TTI. The result is a
percentage figure between 0.0 and 100.0/.
Counter type: Gauge
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least
one device set (EScDeviceSet). That is, state is
operational and the corresponding device board has
correct capability.
The E-DCH scheduler is limited by:
1) RBS HW,
2) Iub bandwidth, and
3) Uu interface resources.
These resource limitations are for this measurement
measured every 100 ms period. Each 100 ms period
that the UE required EUL bit rate (edchGrantRate)

during any of the 2 and/or 10 ms TTIs during the 100


ms period that has been higher than the available
resources and that the only limiting resource during at
least one of these TTIs has been the E-DCH Iub
Scheduler Limit Rate (edchIubSchLimitRate), Then
that 100 ms period is marked as an Iub Limiting
period.
Unit: 0.1/
Undefined value: -1
long[16] nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiOO
The PM counter presents a histogram over the
dynamic delay experienced between SRNC and RBS
by the flow controlled HSDPA flows, that is, the buffer
build-up delay distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least
one DBCC device set. That is, state is operational and
the device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub
and Iur are included in the delay measurement.
Sampled every 100 ms period. The samples are taken
from all the HS-DSCH channels scheduled on priority
class 00.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long[16]
nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiOl
The PM counter presents a histogram over the
dynamic delay experienced between SRNC and RBS
by the flow controlled HSDPA flows, that is, the buffer
build-up delay distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least
one DBCC device set. That is, state is operational and
the device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub
and Iur are included in the delay measurement.
Sampled every 100 ms period. The samples are taken
from all the HS-DSCH channels scheduled on priority
class 01.

PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1
long[16]
nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiO2
The PM counter presents a histogram over the
dynamic delay experienced between SRNC and RBS
by the flow controlled HSDPA flows, that is, the buffer
build-up delay distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least
one DBCC device set. That is, state is operational and
the device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub
and Iur are included in the delay measurement.
Sampled every 100 ms period. The samples are taken
from all the HS-DSCH channels scheduled on priority
class 02.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long
noNotification
nonPersistent
readOnly

long
noNotification
nonPersistent
readOnly

pmDchFramesTooLate
The number of DCH Iub FP frames discarded owing to
too late arrival, that is, after LTOA.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one
DBCH device set. That is, state is operational and the
device board has correct capability.
Undefined value: -1
pmEdchiubLimitingRatio
Indicates in what degree the EUL traffic in uplink is
limited by the Iub/Iur interfaces, between RBS and
SRNC. When a high value is indicated, it should be
considered to extend Iub/Iur with higher EUL bandwidth.
Indicates the percentage of 100 ms periods with
scheduled EUL traffic where Iub has been the only
limiting factor during at least one TTI. The result is a
percentage figure between 0.0 and 100.0/.
Counter type: Gauge
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one
device set (EScDeviceSet). That is, state is operational
and the corresponding device board has correct
capability.
The E-DCH scheduler is limited by:
1) RBS HW,
2) Iub bandwidth, and
3) Uu interface resources.
These resource limitations are for this measurement
measured every 100 ms period. Each 100 ms period that
the UE required EUL bit rate (edchGrantRate) during any
of the 2 and/or 10 ms TTIs during the 100 ms period
that has been higher than the available resources and
that the only limiting resource during at least one of
these TTIs has been the E-DCH Iub Scheduler Limit Rate
(edchIubSchLimitRate), Then that 100 ms period is
marked as an Iub Limiting period.
Unit: 0.1/
Undefined value: -1

long[16] nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiOO
The PM counter presents a histogram over the dynamic
delay experienced between SRNC and RBS by the flow
controlled HSDPA flows, that is, the buffer build-up delay
distribution for HS traffic.
Counter type: PDF

Counter is reset after measurement interval: Yes


Condition: Measurement can be started on at least one
DBCC device set. That is, state is operational and the
device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub
and Iur are included in the delay measurement. Sampled
every 100 ms period. The samples are taken from all the
HS-DSCH channels scheduled on priority class 00.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1
long[16]
nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiOl
The PM counter presents a histogram over the dynamic
delay experienced between SRNC and RBS by the flow
controlled HSDPA flows, that is, the buffer build-up delay
distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one
DBCC device set. That is, state is operational and the
device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub
and Iur are included in the delay measurement. Sampled
every 100 ms period. The samples are taken from all the
HS-DSCH channels scheduled on priority class 01.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long[16]
nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiO2
The PM counter presents a histogram over the dynamic
delay experienced between SRNC and RBS by the flow
controlled HSDPA flows, that is, the buffer build-up delay
distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one

DBCC device set. That is, state is operational and the


device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub
and Iur are included in the delay measurement. Sampled
every 100 ms period. The samples are taken from all the
HS-DSCH channels scheduled on priority class 02.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmEdchiubLimitingRatio
Indicates in what degree the EUL traffic in uplink is limited
by the Iub/Iur interfaces, between RBS and SRNC. When a
high value is indicated, it should be considered to extend
Iub/Iur with higher EUL bandwidth.
Indicates the percentage of 100 ms periods with scheduled
EUL traffic where Iub has been the only limiting factor
during at least one TTI. The result is a percentage figure
between 0.0 and 100.0/.
Counter type: Gauge
Counter is reset after measurement interval: Yes Condition:
Measurement can be started on at least one device set
(EScDeviceSet). That is, state is operational and the
corresponding device board has correct capability.
The E-DCH scheduler is limited by:
1) RBS HW,
2) Iub bandwidth, and
3) Uu interface resources.
These resource limitations are for this measurement
measured every 100 ms period. Each 100 ms period that
the UE required EUL bit rate (edchGrantRate) during any of
the 2 and/or 10 ms TTIs during the 100 ms period that has
been higher than the available resources and that the only
limiting resource during at least one of these TTIs has been
the E-DCH Iub Scheduler Limit Rate
(edchIubSchLimitRate), Then that 100 ms period is marked
as an Iub Limiting period.

Unit: 0.1/
Undefined value: -1
long[16] nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiOO
The PM counter presents a histogram over the dynamic
delay experienced between SRNC and RBS by the flow
controlled HSDPA flows, that is, the buffer build-up delay
distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one
DBCC device set. That is, state is operational and the
device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub and
Iur are included in the delay measurement. Sampled every
100 ms period. The samples are taken from all the HSDSCH channels scheduled on priority class 00.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long[16]
nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiOl
The PM counter presents a histogram over the dynamic
delay experienced between SRNC and RBS by the flow
controlled HSDPA flows, that is, the buffer build-up delay
distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one
DBCC device set. That is, state is operational and the
device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub and
Iur are included in the delay measurement. Sampled every
100 ms period. The samples are taken from all the HSDSCH channels scheduled on priority class 01.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long[16]
nonUnique
noNotification
nonPersistent
readOnly

pmHsDataFrameDelayiubSpiO2
The PM counter presents a histogram over the dynamic
delay experienced between SRNC and RBS by the flow
controlled HSDPA flows, that is, the buffer build-up delay
distribution for HS traffic.
Counter type: PDF
Counter is reset after measurement interval: Yes
Condition: Measurement can be started on at least one
DBCC device set. That is, state is operational and the
device board has correct capability.
The delay is between SRNC and RBS, that is, both Iub and
Iur are included in the delay measurement. Sampled every
100 ms period. The samples are taken from all the HSDSCH channels scheduled on priority class 02.
PDF range:
[0]: Number of samples in range [0..10[
[1]: Number of samples in range [10..20[
[2]: Number of samples in range [20..30[
...
[14]: Number of samples in range [140..150[
[15]: Number of samples >= 150 ms
Unit: 1 ms
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmifinOctetsHi
The number of octets received by a port, including framing
characters and bad packets, but excluding preamble sequences.
The high capacity counter for received octets on an interface is
split into two parts.
This counter represents the higher part of the 62 least significant
bits of the high capacity counter for received octets. The two
most significant bits of this 64 bit counter are discarded.
This 64-bit counter is presented as 2*31 bits: pmIfInOctetsHi
(bit 61-31) and pmIfInOctetsLo (bit 30-0) in the MOM.
Condition: An octet is received.
Counter is reset after measurement period: Yes
Counter type: PEG Unit:
Number of octets
Specification: RFC 2863

long

pmifinOctetsLo

noNotification
nonPersistent
readOnly

The number of octets received by a port, including framing


characters and bad packets, but excluding preamble sequences.
The high capacity counter for received octets on an interface is
split into two parts.
This counter represents the lower part of the 62 least significant
bits of the high capacity counter for octets transmitted out on
the interface. The two most significant bit of this 64 bits counter
are discarded.
This 64-bit counter is presented as 2*31 bits: pmIfInOctetsHi
(bit 61-31) and pmIfInOctetsLo (bit 30-0) in the MOM.
Condition: An octet is received.
Counter is reset after measurement period: Yes
Counter type: PEG Unit:
Number of octets
Specification: RFC 2863

long
noNotification
nonPersistent
readOnly

pmifinOctetsLo
The number of octets received by a port, including framing
characters and bad packets, but excluding preamble sequences.
The high capacity counter for received octets on an interface is split
into two parts.
This counter represents the lower part of the 62 least significant
bits of the high capacity counter for octets transmitted out on the
interface. The two most significant bit of this 64 bits counter are
discarded.
This 64-bit counter is presented as 2*31 bits: pmIfInOctetsHi (bit
61-31) and pmIfInOctetsLo (bit 30-0) in the MOM.
Condition: An octet is received.
Counter is reset after measurement period: Yes
Counter type: PEG Unit:
Number of octets
Specification: RFC 2863

long
noNotification
nonPersistent
readOnly

pmifOutOctetsHi
The number of octets transmitted by a port, including framing
characters and bad packets, but excluding preamble sequences.
The high capacity counter for octets transmitted out on an interface
is split into two parts.
This counter represents the higher part of the 62 least significant
bits of the high capacity counter for octets transmitted out on the
interface. The two most significant bits of this 64 bits counter are
discarded.
This 64-bit counter is presented as 2*31 bits: pmIfOutOctetsHi (bit
61-31) and pmIfOutOctetsLo (bit 30-0) in the MOM.
Condition: An octet is transmitted.
Counter is reset after measurement period: Yes
Counter type: PEG Unit:
Number of octets
Specification: RFC 2863

long
noNotification
nonPersistent
readOnly

pmifOutOctetsLo
The number of octets transmitted by a port, including framing
characters and bad packets, but excluding preamble sequences.
The high capacity counter for octets transmitted out on an interface
is split into two parts.
This counter represents the lower part of the 62 least significant
bits of the high capacity counter for octets transmitted out on the
interface. The two most significant bits of this 64 bit counter are
discarded.
This 64-bit counter is presented as 2*31 bits: pmIfOutOctetsHi (bit
61-31) and pmIfOutOctetsLo (bit 30-0) in the MOM.
Condition: An octet is transmitted.
Counter is reset after measurement period: Yes
Counter type: PEG Unit:
Number of octets
Specification: RFC 2863

long
noNotification
nonPersistent
readOnly

pmNoActivelOmsFramesEul
Sum of used 10 ms frames (TTI) that receive E-DCH
data in a cell during an ROP for all E-DCH users,
excluding frames that are not decoded due to lack of
hardware.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Every 10 ms TTI that receives E-DCH data
that is active, excluding frames that are not decoded due
to lack of hardware. The actual measurement is started
when the EUL resources are setup.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmNoActivelOmsintervalsEulTtilO
Counter for the total amount of 10 ms intervals in a cell
in which the transmission of one or more E-DCH frames
has been detected, exluding frames that are not decoded
due to lack of hardware to decode the frame.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped every 10 ms for 10 ms TTI users on
the reception of any MAC-e PDU in the last 10 ms.
Frames that are not decoded due to lack of hardware to
decode the frame are excluded from contributing to the
count. The actual measurement is started when the EUL
resources are setup.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmNoActive2msFramesEul
Sum of used 2 ms frames (TTI) that receive E-DCH data
in a cell during an ROP for all E-DCH users, excluding
frames that are not decoded due to lack of hardware.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Every 2 ms TTI that receives E-DCH data that
is active.
Note that if e.g. 3 users transmit during a specific 2 ms
period, the counter will be incremented by 3.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmNoActive2msintervalsEul
Counter for the total amount of 2 ms intervals in a cell in
which the transmission of one or more E-DCH frames
has been detected, excluding frames that are not
decoded due to lack of hardware to decode the frame.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped after a successful decoding of a MAC-

e frame. Counted for both 10 ms TTI and 2 ms TTI users.


Frames that are not decoded due to lack of hardware to
decode the frame are excluded from contributing to the
count. A 10 ms frame is counted as 5 intervals and a 2
ms frame is counted as 1 interval. Note that no interval
may be counted more than once. The actual
measurement is started when the EUL resources are
setup.
Undefined value: -1
long
noNotification
nonPersistent
readOnly

pmNoActive2msintervalsEulTti2
Counter for the total amount of 2 ms intervals in a cell in
which the transmission of one or more E-DCH frames
has been detected, excluding frames that are not
decoded due to lack of hardware to decode the frame.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped every 2 ms for 2 ms TTI users on the
reception of any MAC-e PDU in the last 2 ms. Frames
that are not decoded due to lack of hardware to decode
the frame are excluded from contributing to the count.
The actual measurement is started when the EUL
resources are setup.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmNoActive2msFramesEul
Sum of used 2 ms frames (TTI) that receive E-DCH data in a cell
during an ROP for all E-DCH users, excluding frames that are not
decoded due to lack of hardware.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Every 2 ms TTI that receives E-DCH data that is active.
Note that if e.g. 3 users transmit during a specific 2 ms period, the
counter will be incremented by 3.
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmSumAckedBitsCellEulTtilO
Counter for the total amount of acked data received in kbits after
HARQ process on MAC-e level for all 10 ms TTI users in a cell. Note
that k = 1000.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped every 10 ms for 10 ms TTI users when received
data are acknowledged after HARQ process. The actual
measurement is started when the EUL resources are setup.

Unit: kbits
Undefined value: -1

long
noNotification
nonPersistent
readOnly

pmSumAckedBitsCellEulTti2
Counter for the total amount of acked data received in kbits after
HARQ process on MAC-e level for all 2 ms TTI users in a cell. Note
that k = 1000.
Counter type: Peg
Counter is reset after measurement interval: Yes
Condition: Stepped every 2 ms for 2 ms TTI users when received
data are acknowledged after HARQ process. The actual
measurement is started when the EUL resources are setup.
Unit: kbits
Undefined value: -1

You might also like