NAME OF PROJECT
CLIENT
LOCATION
PROJECT NUMBER
UPGRADTION OF OF POWER STACK FANS IN DR MODULE A & B
SAUDI IRON AND STEEL COMPANY - HADDED
:
JUBAIL NDUSTRIAL CITY, AL-JUBAIL, KINGDOM OF SAUDI ARABIA
:
AF-1221089
:
CAMERON FINAL DIMENSION & VISUAL INSPECTION REPORT
Stack B / STC4- Final Visual Dimensional Inspection
SR. NO.
DESCRIPTION
REQUIRED (mm)
ACTUAL (mm)
OUTSIDE CIRCUMFERENCE
9475
9478
2
3
SHELL INTERNAL DIAMETER
FLANGE OUTSIDE DIAMETER
3000
3251
3000
3251
OVER ALL LENGTH
11475
11473
REMARKS
OVERALL INSPECTION RESULTS
AT
"A" (REQ. 11475 mm)
ACTUAL
AT
ACTUAL
11474
11473
11474
11473
0
90
180
270
"B" ( REQD: 3200 mm)
AT
ACTUAL
AT
ACTUAL
3201
3202
123 - 303
159 - 339
3202
3202
33 - 213
69 - 249
"A"
ROUNDNESS / OVALITY READINGS
REQ. ID = 3000 MM
AT
TOP
BOTTOM
"B"
AT
0
90
180
270
0 - 180
3000
MAX. ALLOWED OUT OF ROUNDNESS :30 mm
OUT OF
45 - 225 90 - 270 135 - 315
ROUNDNESS
3002
2999
2997
3017
2983
2987
CS-1
1
50
52
52
52
2
50
52
52
52
1
48
54
53
52
3021
ALIGNMENT READINGS ref. 51mm
CS-2
CS-3
2
1
2
48
54
53
54
54
54
48
50
50
52
48
48
CS-4
1
2
51
52
52
52
48
48
50
50
OUT OF
ALIGNMENT
5
2
4
4
NOTE:
SISCO QC
NAME
SIGNATURE
DATE
NORMAN MORALES
SABIC - HADEED
REMARK