NAME OF PROJECT

CLIENT
LOCATION
PROJECT NUMBER

UPGRADTION OF OF POWER STACK FANS IN DR MODULE A & B


SAUDI IRON AND STEEL COMPANY - HADDED
:
JUBAIL NDUSTRIAL CITY, AL-JUBAIL, KINGDOM OF SAUDI ARABIA
:
AF-1221089
:

CAMERON FINAL DIMENSION & VISUAL INSPECTION REPORT


Stack B / STC4- Final Visual Dimensional Inspection
SR. NO.

DESCRIPTION

REQUIRED (mm)

ACTUAL (mm)

OUTSIDE CIRCUMFERENCE

9475

9478

2
3

SHELL INTERNAL DIAMETER


FLANGE OUTSIDE DIAMETER

3000
3251

3000
3251

OVER ALL LENGTH

11475

11473

REMARKS

OVERALL INSPECTION RESULTS

AT

"A" (REQ. 11475 mm)


ACTUAL
AT

ACTUAL

11474
11473

11474
11473

0
90

180
270
"B" ( REQD: 3200 mm)

AT

ACTUAL

AT

ACTUAL

3201
3202

123 - 303
159 - 339

3202
3202

33 - 213
69 - 249

"A"
ROUNDNESS / OVALITY READINGS
REQ. ID = 3000 MM
AT
TOP
BOTTOM

"B"

AT
0
90
180
270

0 - 180
3000

MAX. ALLOWED OUT OF ROUNDNESS :30 mm


OUT OF
45 - 225 90 - 270 135 - 315
ROUNDNESS
3002
2999
2997

3017

2983

2987

CS-1
1
50
52
52
52

2
50
52
52
52

1
48
54
53
52

3021

ALIGNMENT READINGS ref. 51mm


CS-2
CS-3
2
1
2
48
54
53
54
54
54
48
50
50
52
48
48

CS-4
1
2
51
52
52
52
48
48
50
50

OUT OF
ALIGNMENT

5
2
4
4

NOTE:

SISCO QC
NAME
SIGNATURE
DATE

NORMAN MORALES

SABIC - HADEED

REMARK