You are on page 1of 4

PSU OUTPUT Vs.

CONTROL - VARIABLE REFERENCE


2.5000

VARIABLE REFERENCE, V

2.0000

1.5000

1.0000

0.5000

0.0000
10

20

30

40

50

60

OUTPUT VOLTAGE, V

70

80

90

100

110

DESCRIPTION

DATA

VA

Control Vc

GAIN A

(Vo reduced)

(manual contr.)

(OP AMP)

50

Variable VR

Current

Ia

VR=(Vc/A)+VA
4

Vo MAX, V

100

0.186

2.0465

Vo MED, V

50

0.562

1.1405

Vo MIN, V

20

0.4

1.6

0.8000

DATA

Fixed VR

DESCRIPTION

Control Vc

GAIN A

Variable VA

(manual contr.)

(OP AMP)

(Vo reduced)

0.6

VA=VR-(Vc/A)
4

Vo MAX, V

100

0.186

0.5535

Vo MED, V

50

0.562

0.4595

Vo MIN, V

20

1.6

0.2000

DESCRIPTION

CALC.

Time constants
R1, Ohm

1,681

R2, Ohm

82,353

C1, uF

220

Tau 1, sec.

0.4

Tau 2, sec.

18.1

A
0.00119

R1

R2

Ohm

Ohm

1,681

82,353

PSU OUTPUT Vs.CONTROL - FIXED REFERENCE


0.6000

0.5000

POT VOLTAGE VA, V

0.4000

0.3000

0.2000

0.1000

0.0000
10

20

30

40

50

60

OUTPUT VOLTAGE, V

70

80

90

100

110

You might also like