You are on page 1of 13

General Notes

27,930

PLOT AREA: ..............431.101 sq.m.

1200
150

3
,
00
0

Built up area:
Ground oor........334.41sq.m.
Typical 1st to 7th.....334.41 x7
=2340.87sq.m.
Basement..........334.41 sq.m.
Total built up area=3009.69 sq.m.
Plot ratio:.................. 6.9
Plot coverage:............75%

LOUNGE

6,000

RESTAURANT

11

15
0=

3,425
OPEN TO
BELOW

MANAGER'S
OFFICE

10
20
7

17
4

19
6

LAUNDRY

18

STAFF CHANGING
ROOM

3,0
00

RECEPTION

15500

150

20
x

KITCHEN

12

14

13

13,896

15
3

16

2,876

2,174
1200

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

14500

13,803
30,000

GSPublisherEngine 0.0.100.100

CONSULTANT:

Title:
Designed by

site hotel

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:125

E.S.

11/3/2015

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

GSPublisherEngine 0.0.100.100

Title:
Designed by

BASEMENT

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:100

E.S.

11/3/2015

General Notes

24,650
4,650

5,200

4,950

5,200

4,650

150

5,000

LOUNGE

6,000

5,000

RESTAURANT

150

13,500

PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

THEODORA PIUS MWANSASU


P.O. BOX 3690 DAR ES SALAAM

3,500

11
10

17
4

GSPublisherEngine 0.0.100.100

5,000

24,650

5,200

S2

Client:

3,425
OPEN TO
BELOW

4,950

MANAGER'S
OFFICE

20
7

19
6

LAUNDRY

18

5,200

STAFF CHANGING
ROOM

3,0
00

3,500
4,650

RECEPTION

15
0=

KITCHEN

20
x

16

12

14

S2

13

5,000

15

Project Title:

CONSULTANT:

4,650
Title:
Designed by

GF HOTEL

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:100

E.S.

11/3/2015

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

GSPublisherEngine 0.0.100.100

Title:
Designed by

HOTEL

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:100

E.S.

11/3/2015

General Notes

2
S-S

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

S-S

3
Client:

THEODORA PIUS MWANSASU


P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

GSPublisherEngine 0.0.100.100

Title:
Designed by

ROOF PLAN

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:100

E.S.

11/3/2015

General Notes

+29.0

1800

3180

754

APARTMENTS

3,150

3,000

150

445

+25.8

3,150

3,000

150

1000

+22.65

APARTMENTS

3,150

3,000

150

1000

+19.5

APARTMENTS

3,150

3,000

150

1000

+16.35

APARTMENTS

150

1000

+13.2

PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

1000

3,000

APARTMENTS

3,150

300
1,800

3,000

150

APARTMENTS

+6.9

Client:

APARTMENTS

3,150

3,000

150

APARTMENTS

1000

APARTMENTS
900

+10.05

3,150

Project Title:

P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:
3,753

3,603

150

1000

+3.75

THEODORA PIUS MWANSASU

SHOPS

2,280

150

0.00

4,650

GSPublisherEngine 0.0.100.100

5,200

BASEMENT

4,950

5,200

4,650

Title:
Designed by

SECTION

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:150

E.S.

11/3/2015

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

3,500

5,000

FRONT ELEVATION

GSPublisherEngine 0.0.100.100

5,000

5,000

5,000

REAR ELEVATION

Title:
Designed by

ELEVATION

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:125

E.S.

3,500
11/3/2015

10

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

4,650

GSPublisherEngine 0.0.100.100

5,200

4,950

5,200

4,650

Title:
Designed by

RIGHT ELEVATION

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:125

E.S.

11/3/2015

11

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

4,650

GSPublisherEngine 0.0.100.100

5,200

4,950

5,200

4,650

Title:
Designed by

LEFT ELEVATION

Drawn by

O.S.

Scale:
Date:
Sheet No:

1:125

E.S.

11/3/2015

12

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

GSPublisherEngine 0.0.100.100

Title:
Designed by

IMAGES

Drawn by

O.S.

Scale:
Date:
Sheet No:

11/3/2015

E.S.

13

General Notes

Project Title:
PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM

Client:
THEODORA PIUS MWANSASU
P.O. BOX 3690 DAR ES SALAAM

CONSULTANT:

GSPublisherEngine 0.0.100.100

Title:
Designed by

IMAGES

Drawn by

O.S.

Scale:
Date:
Sheet No:

11/3/2015

E.S.

14

General Notes

L
493

2,321

493

493

493

600x450mm SABS type 9C


cover and frame

tto

493

SEPTIC TANK PLAN


1:20

600x450mm SABS type 9C


cover and frame

322

110mm perforated
pitch - fibre pipe
Approved bidding
cloth all round

1,287

20-75 mm Clean Granular


fill tampered in place in the
percolation trench.

SECTION 3 - 3
1:20

600x450mm SABS type 9C


cover and frame

600x450mm SABS type 9C


cover and frame

GL

sand

GL

600x450mm SABS type 9C


cover and frame

GL

GL

GL

644

429

493

600x450mm SABS type 9C


cover and frame

536

1,287

493

uled

DISTRIBUTION BOX
1:20

GL

493

1,952

&b o

hed

600x450mm SABS type 9C


cover and frame

1,287

top

s sc

493

965

ith

sh a

493

m
150

19 w
25/
ade
b gr
.c.sla
r
m

e
mm

1,287

493

493

215

3,772

1000mm min variable

493

493

644

493

579

644
Approved geotextile
membrane

483

230mm baffle
wall

483

225

493

1,287

15mm sand/cement
plaster to internal walls

965 322

1,287

322

322

fluid level

1,286

1,287

Project Title:
Honeycomb
brickwork.

322

PROPOSED RESIDENTIAL /
COMMERCIAL BUILDING TO BE
BUILT ON PLOT NO 188 BLOCK A
KIGOGO DAR ES SALAAM
150mm conc.grade 20/19
with mesh S193

493

SECTION 1 - 1
1:20

Capacity

"W" [m]

"L" [m]

Cu. m

10mins

15mins

30mins

1.200

1.000

2.800

3.450

5.000

7.500

10.000

15.000

20.000

245

1.350

1.000

3.100

4.185

7.500

11.250

15.000

22.500

30.000

245

1.500

1.000

3.300

4.950

10.000

15.000

20.000

30.000

40.000

21-25

245

1.500

1.100

3.800

6.270

12.500

18.750

25.000

37.500

50.000

26-35

395

1.500

1.250

4.500

8.440

17.500

26.250

35.000

52.500

70.000

36-50

395

1.750

1.450

4.750

12.050

25.000

37.500

50.000

75.000

100.000

51-75

395

1.750

1.650

5.250

15.160

35.000

52.250

70.000

105.000

130.000

76-100

395

1.750

1.790

6.000

18.795

45.000

60.000

75.000

120.000

145.000

Depth "D" [m]

10 or Less

245

11-15

16-20

493

493

493

1,287

493

493

SECTION THROUGH A SUMP


1:20

Client:
THEODORA PIUS MWANSASU

3,218

Length

Sewage

Roof Slab
mesh

493

P.O. BOX 3690 DAR ES SALAAM

SOAKAWAYS LENGTH "S" [m]

SEPTIC TANK DETAILS


No. of
Persons

SECTION 2 - 2 1:20

SCHEDULE OF SEPTIC TANK AND SOAKAWAYS

Type

493

Width

Percolation Rate (minutes per 25mm)


>4mins

5mins

STANDARD PERCOLATION TEST PROCEDURE

CONSULTANT:

1. Excavate percolation test hole with diameter between 100mm to 300mm


at a depth of soakaway trench by hand or auger.
2. Cover the bottom of the test hole with 50mm layer of 20mm crushed stones to
protect the bottom of from scouring.
3. Soak the ground by filling the test hole with water to a depth of 300mm and
maintain this level by adding water for at least four (4) hours. (In sand soil with
little or no clay soaking is not necessary).

Reference Board

Measuring stick

4. Fill the test hole with water to a depth of 150mm and measure the drop of
water level over a period of 30 minutes or until the water has drained away.
(At least three measurement are to be made)

50mm of crushed
stones to prevent scour

107

644

Test Hole

Title:
Designed by

SEPTICS

Drawn by

O.S.

Scale:
Date:
Sheet No:

11/3/2015

TYPICAL PERCOLATION TEST HOLE 1:20

GSPublisherEngine 0.0.100.100

E.S.

15