eaves over required windows not < 750mm. minimum over from the side & rear property lines
Sanitation
Foundation
Floor
Roof
Stairs
14m or over
Total Projections
.60m
.90m
1m
1.10m
1.30m
1.40m
1.50m
not < 2.40m above pavement or GL shall not, when fully opened, project beyond PL except fire exit doors
Section 1008. Corner Bldgs. with Chaflans
a. Public Street or alley < 3.60m in width shall be truncated at the corner Chaflan
b. If arcaded bldg, no chaflan reqtd notwithstanding the width of public street, < 12.00m
Chapter 11: Protection of Pedestrians during Construction or Demolition
Section 1105. Walkway
a. Temporary walkway 1.20m wide (during construction
b. Capable of supporting a uniform live load of 650 kg per sq.m
Section 1106. Pedestrian Protection
a. Railings street side of the sidewalk at least 1m in height
b. Fences not < 2.40m above grade
c. Canopies 2.40m above the railway, live load 600 kg per sq.m.
Section 1107. Maintenance and Removal of Protective Devices
a. Removal protective fence or canopy shall be removed 30 days after protection no longer required.
Chapter 12: General Design & Construction Requirements
Section 1202. Excavation, Foundation, and Retaining Walls
a. Excavation and Fills
1. Excavation made on public property - restored immediately to its former conditions w/in 48 hrs
Exits
1.
Number of Exits
Above 1st storey 10 occupant 2 exits
Mezzanine 185 sq.m area or more than 18m in dimension 2 exits
500-999 3 exits
2. Exits if only 2 exits required, shall be placed distance apart not < 1/5 of the perimeter area.
3. Distance of Exits w/o sprinkler 45m from exterior exit door, w/ sprinkler 60m
4. Doors
a. Swing exit door shall swing to exit travel in hazardous areas w/ 50 or more occupant load
b. Double acting doors view panel of not < 1,300 sq. cm.
c. Width and Height not < 900mm in width, not < 2.00m in height, opening 90 degrees and exit way
clear width not < 700mm
5. Door Leaf Width max of 1.20
6. Corridors and Exterior Exit Balconies
a. Width not < 1.10m
b. Dead Ends max 6.00m in length
7. Stairways
a. Width serving an occupant load of more than 50 shall not be < 1.10m, occupant load of 50 or less
may be 90m (900mm) wide, private stairways serving an occupant load of < 10 may be .75m
(750mm)
b. Rise and Run. Rise max 0.20m (200mm), Run - 0.25m (250mm)
c. Winding Stairways narrower side of the thread 150mm 300mm
d. Circular Stairways used as exit w/ min width of run not < 250mm
e. Landings straight run max of 1.20m, vertical
f.
Distance bet landings max of 3.60m vertical distance landings.
g. Handrails not < 800mm nor more than 900mm.
h. Stairway to Roof if 4 or more storeys in height
i.
Headroom clearance 2.00m
8. Ramps width 1.10m min
9. Exit Outlets, Courts, Passageways
a. Slope exit courts max of 1:10, exit passageway max of 1:8
b. Openings on exit court not < 3.00m protected by fire assemblies not < hour fire resistive. Except
openings > 3.00m may be unprotected
c. Exit signs illumination not < 10.7 lux at the floor level
10. Aisles
a. Width not < 800mm if serving one side, not < 1m if serving both sides, side aisles shall not < 1.10m
b. Exit Distance
1. Groups H, I occupancies w/o seats, line of travel to exit door by an aisle is not > 45.00m
2. Exit doors clear width 1.70m if 30 seats bet aisles and 1m distance of seat back to back
c. Slope max of 1:8
11. Seats
a. Seat Spacing - spacing of rows of seats from back to back not < 840mm (standard seating), Clear width of
rows (continental seating) as follows:
450 mm
Rows of 18 seats
500mm
Rows of 35 seats or less
520mm
Rows of 45 seats or less
550mm
Rows of 46 seats or more
b. Width not < 450mm (0.45m) min, max of 480 (0.48m)
12. Reviewing Stands, Grandstands, and Bleachers
a.
Row Spacing (min)
600 mm
w/o backrest in open air stand
750mm
Seats w/ backrest
850mm
Chair seating
Not < 300mm
Bet the back of each seat and the front
of the seat immediately behind it
b.
c.
1.
d.
Ports required limited in area to 750 sq.cm, not more than 1 observation ports w/c be limited to 1300
sq.cm. There shall be not more than 3 combination ports w/c not exceed 750mm by 600mm.
Projection ports not to exceed 4,500 sq.cm in area.
Ventilation
1. Inlet fresh air inlet from the exterior bldg. not < 900sq.cm. & protect w/ wire netting installed w/in 50mm
of the floor in every projection room
2. Outlets provide 1 or more mechanical exhaust systems.
Definitions
a. Building Permit a written authorization granted by the BO to an applicant allowing the applicant to proceed w/ the
construction w/ specific project after plans, specs and other pertinent doc.
b. Construction All on site work done
c. Erection installation of components of a building/structure
d. Addition new construction w/c increases the height or area of an existing bldg./structures.
e. Alteration changes in materials, utilities, partitioning, etc but doesnt increase the overall area thereof.
f.
Renovation physical change made to increase its value & improve its aesthetic quality.
g. Conversion change in use or occupancy
h. Repair remedial work done on any damaged/deteriorated portion of bldg.
i.
Moving transfer of any bldg. from original location to another
j.
Demolition systematic dismantling of a bldg in whole or part.
k. Ancillary Bldg./Structure secondary bldg. located w/in the same premises the use of incidental to that main bldg.
2.
3.
Architectural Documents
Location plan w/in 2km radius COM, IND and INS, w/in half km radius Residential
Site Development Plan 1:200m
Floor Plans
Elevation at least 4
Section at least 2
Foundation plan
Floor-framing plan
Roof-framing plan
Footing/column detail
Structural members detail
4.
Exemptions:
1. Voltage bet conductors doesnt exceed 300 volts and has roof slope not < 100mm in 300mm slope.
2. Service drop conductors of 300 volts or less w/ a max of 1.2m overhang portion of roof for the purpose of
a service raceway may be maintained at min of 500mm.
b. From Ground conductors shall not < 3m from any platform or projection.
c. From Building Openings conductors shall have clearance of < 1m from windows, doors, etc and shall be run at
least 500mm above the top level of a window or opening.
d. Service Drop of Communications lines, when crossing a street, have a clearance not < 5.50m from the crown of
street/sidewalk. Also have a min clearance of 3.00m above the ground.
Provisions for Transformer Vaults
4.1
New Building load demand 200KVA or above provided w/transformer vault
4.2
Location ventilated to outside air
4.3
Walls, Roof and Floor. Reinforced concrete not < 150mm, masonry/brick not less than 200mm,
300mm load bearing hollow concrete blocks. Inside wall and roof surface constructed of HCB shall have a
coating of cement/gypsum plaster not < 20mm. Concrete floor not < 100mm thick.
5.
Ventilation
5.1
Ventilation Openings
5.1.1.
Size not < .006sq.mm per KVA of transformer capacity in service, except the net are shall not be
< 0.1sqm for any capacity under 50KVA
5.1.2.
Drainage vaults w/ more than 100KVA transformer capacity shall be provided w/ drain
6. Capacitors
6.1
Transformers Used w/ Capacitors KVA rating shall not be < 135% of capacitor rating
Rule X Mechanical Regulations
1. Elevators
1.1
Hoistway pits clearance of not < 600mm remains bet the underside of car & bottom of pit.
1.2
Min number of hoisting ropes shall be 3 for traction elevators and 2 for drumtype elevators.
1.3
Min diameter of hoisting & counterweight ropes shall be 30mm
1.4
Elevators w/ over-load relay and reverse polarity relay.
1.5
In high rise apts. or residential condos of more than 5 stories, at least 1 passenger elevator shall be kept on
24 hour constant service.
2. Escalators
2.1
Angle of inclination shall not exceed 35 degrees from the horizontal
2.2
Width bet balustrades shall not be < 558 mm nor more than 1.20m. The width shall not exceed the width
of the steps by more than 330mm.
2.3
Rated speed, not more than 38mpm.
3. Boilers and Pressure Vessels
3.1
Location
3.1.1
Main Bldg. is not made up of fire resistive materials, boilers shall be located outside w/ distance not <
3.00m outside the wall of main bldg. & bldg. housing the boiler
3.1.2
No part of the boiler shall be closer than 1m from any wall
3.2
Smokestacks - shall able to withstand a wind load of 175km per hour & shall rise at least 5m above the
eaves of any bldg. w/in a radius of 50m.
3.3
Boilers more than 46sq.m. heating surface shall be provided w/ 2 means of feeding water, 1 steam driven
and 1 electrically driven, 1 pump and 1 injector.
3.4
2 check valves shall be provided bet any feed pump and boiler
3.5
Boilers rms. shall have at least 2 separate exits.
3.6
Each boiler shall at least 1 safety valve. Having more than 46.sq.m pressure of water heating
surface/generating capacity exceeding 97kg. per hour, 2 or more safety valves are required.
4. Refrigeration and Air Conditioning
4.1
68-74 degrees F temperature and humidity for comfortable cooling, 4.57 to 7.60 MPM temperature at an air
movement.
4.2
Not more than 136kgs of refrigerant shall be stored in a machine rm.
4.3
Where ammonia is used into a tank of water at least 1 gallon of water shall be provided for every .04536kg of
ammonia in the system.
4.4
Refrigerant piping crossing a passageway in any bldg. shall not < 2.3m above the floor.
4.5
Window type AC (Air Con) shall not be < 2.13m from the ground
5.
6.
Pneumatic Division
Gas Division
Fuel Oil Division
Refrigerating Division
Interior/rear lots access road w/ min width depending upon the no. of
bldgs./units approve by local planning authority
Multiple living units on same lot. (Apartments,
rowhouses/accesorias/groups of single-detached bldgs)
Up to 6 units
7-15 units
16-25 units
26-35 units
More than 35 units
Access Roads
Not < 3.00m wide
3.00
4.00
5.00
6.00
7.50
wide
wide
wide
wide
wide
1.4
4.6
8.4
7.4
3.25
2.8
6
50
5.6
9.3
46.5
18.6
10
28
30
50
30
30
9.3
.65
10
50
3.
4.
Fence erected @ sidewalks/walkways not < 2.40m in height above curb line.
Canopy
4.1
Protective canopy - 2.40m above the walkway
Protection
Required
Railing
None
Fence &
Canopy
Fence &
Canopy
Fence
None
4.2
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Railings not < 1m high and solid toe boards not < 300mm placed along the street and ends of the canopy.
Canopy safely sustaining a load of 800kg per sq.m.
4.3
Underside of canopy properly lighted not < one (1) 100 watt bulb every 6m of its length
Protective Nets/Screen G.I wire gauge 16,38mm mesh nylon net; canvas
Walkways & Railings
6.1
Temporary walkway adjacent to the street line not more than 1.20m wide (for the use of pedestrians).
Where the road right of way is 5m or less, no temporary walkway shall be allowed
6.2
Width of walkway shall not < 1.20m but more than 1/3 the width of the sidewalk.
6.3
Walkways capable of supporting uniform live load of 650kg per sq.m.
6.4
Railings not < 1m in height
Precautionary Measures
7.1
Every Trench, 1.50m or more in depth, provided w/ means of exit at least 7.50 of its length
Storage of Materials
8.1
No materials piled/stacked higher than 1.8m except in yards/sheds. When Piles exceed 1.2m height,
material be arranged that the sides & ends of the piles taper back.
Fire Protection
9.1
All buildings 1 standpipes outlet @ each floor.
9.2
In every construction at least 1 approved handpump, tank or portable chemical or dry fire extinguisher.
9.3
No material/construction equipment shall be placed w/in 3m of such hydrant/connection bet it and the center of
the street.
Sanitation & First Aid
10.1
Where more than 200 workers are employed, a properly first-aid room shall be provided w/ a
physician/nurse.
Temporary Light & Power
11.1
Passageways, stairways and corridors average light intensity not < 2 foot candles.
11.2
Locations where tools & or machinery are used 5 foot candles.
Hoist Towers shall be screened/protected on all sides not < 1.80m height
Ladders & Temporary Stairways
13.1
Stairways shall be erected as the bldg. exceeds 18.00m in height
13.2
No single ladder shall exceed 6.00m in length. Ladder landings at least 1.20m w/ handrails & toe
boards. Ladder rungs shall be spaced uniformly as near to 30mm.
13.3
Ladders leading to floors, stagings/platforms shall be at least 900mm above level of such floors
13.4
Ladders serving traffic in both directions simultaneously at least 1m wide.
13.5
Ladders shall not be painted, inspected at least once every 30 days.
13.6
Stairs and Stairways shall be support a load at least 490kq./sq.m
13.7
Temporary stairs (the sum of the 2 risers and width of 1 tread shall not < 160mm nor more than 660mm)
2R+T=160mm-660mm. Not < 915mm wide. Landings not < 762mm long
Runways & Ramps
14.1
At least (3) three 250mm planks
14.2
Slope not steeper than 1:3
14.3
When riser is steeper than 1:6, or more than 1.8m and steeper than 1:8, runways/ramps shall be provided
w/ cleats spaced not more than 200mm apart
14.4
Total rise of more than 1.80m passing over/near floor openings
Scaffolds
15.1
Support at least 4 times the max load.
15.2
Planks used in construction shall be not < 50mm nominal thickness, overlap at the end shall not < 150mm
15.3
Ropes, cables and blocks used in support shall be sufficient size & strength to sustain @ least 6 times the
max load
15.4
Platform level of w/c is more than 1.80m above the ground
15.5
Substantial overhead protection not more than 3m above the scaffold platform
Floor Openings
16.1
Used as hoistways/elevator shaftways be protected all sides, expect the side used for loading & unloading.
Protection shall be in barricades not < 1.20m high near the edges of openings, guard rails not < 910mm
high placed not < 600mm.
16.2
Solid barriers not < 910mm high
Guard Rails & Toe Boards
17.1
Guard Rails - Top rail not < 910mm high above the platform level. An intermediate rail shall be provided bet
the top rail & the platform. Guard rails shall have supports not more than 2.40m apart, shall be constructed to
withstand a horizontal force of 30kgs. per meter
17.2
Toe Boards shall extend not < 150mm above the platform level. Toe Boards of Wood shall not < 25mm
nominal thickness w/ supports not more than 1.20m apart, Metal shall not < 3.175mm thick w/
supports not more than 1.20m apart.
Chutes
18.1
Chutes for removal of materials & debris shall be provided in demolition operations w/ are more than 6m above pt.
of material to be removed
18.2
Intervals of 7.60m or less w/ substantial stops to prevent descending matls
18.3
Chutes w/c at an angle 45 degrees from the horizontal be enclosed on all 4 sides
18.4
Chutes w/c at an angle 45 degrees from the horizontal may be left open on the upper side
18.5
Openings into matls/debris are dumped are dumped at the top of a chute shall be protect by a substantial
guardrail extending @ least 1.90m above the level of the floor
b.
Courts unoccupied space bet bldg. lines & lot lines other than yard: free, open and unobstructed from the ground
upward.
a. Inner court bounded on all sides/around its periphery by bldg. lines.
b. Open court bounded by 3 sides by bldg. lines w/ 1 side bounded by another open space
c. Through court bounded on 2 opposite sides by bldg. lines w/ the other opposite sides bounded by other open
space.
Every court shall have a width not < 2.00m for 1 and 2 storey bldgs. This may reduced to not < 1.50m in
cluster living units (quadruplexes, rowhouses) for 1 or 2 storeys in height w/ adjacent courts w/ area not <
3.00m. Irregularly shaped lots like triangular shall be < 3.00m
Bldgs more than 2 storeys in height, min width of the court shall be increased at the rate of 300mm
YARD
Front
Side
Rear
R-1
R-2
R-3
R-1
5.00m
2.00m
2.00m
R-3
Setbacks vacant space bet the bldg. & lot lines not < 2.00m in width
4.
Ceiling Heights
4.1 Table Form
Habitable rooms provided w/ artificial ventilation
Bldgs. of more than 1st storey
2nd storey
Succeeding storeys
Above stated rooms w/ natural ventilation
Mezzanine Floors
5.
8.
Window Openings
7.1
Windows w/ a total free area of openings equal to @ least 10% of the floor area of the room, provided that
such opening not < 1sq.m. Toilet, laundry, & similar rooms shall be provided w/ windows w/ area not <
240mm.
7.2
Eaves over required windows not < 750mm from the side & rear Property Lines.
Vent Shafts
8.1
8.2
Horizontal cross sectional area (CSA) of not < 0.10sq.m for every meter of height of shaft but in no case shall the
area be < 1.00sq.m. No vent shaft have its least dimension less < 600mm
Air ducts min unobstructed CSA not < 0.30 sq.m w/ min dim. of 300mm above the bottom of the shaft
Parking space ratings listed are min off street requirements for specific uses/occupancies for bldg./structures:
Average automobile
Truck or bus
1.2 Low Income Single Detached living units in
housing project areas w/ individual lots not more
than 100sq.m
1.3 Multi family units
a. Up to 50sq.m
w/ unit floor of:
b. Above 50sq.m to
100sq.m
c. More than 100sq.m
1.4 Hotels
1.5 Residential Hotels & Apartels
1.6 Motels
1.7 Neighborhood shopping center
1.8 Markets
1.9 Restaurants, fast-food centers, bars and
beerhouses
1.10 Nightclubs, supperclubs and theaterrestaurants
1.11 Office Bldgs
1.12 Pension/Boarding/Lodging houses
1.13 Other Bldgs in Business/Commercial Zones
1.14 Public assembly bldgs such as theaters,
cinemas, etc.
1.15 Places of Worship & Funeral Parlors
1.16 Schools
Elementary, Secondary,
Vocational & Trade schools
College & Univ.
1.17 Hospitals
1.18 Recreational
Bowling Alleys
Facilities
Amusement Centers
Clubhouses, beach houses
and the like
1.19 Factories, manufacturing establishments,
mercantile bldgs, warehouses and storage bins
1.20 Tourist bus parking areas
slot/living unit
slot/10 rooms
slot/5 rooms
slot/unit
slot/100 sq.m of shopping floor area
slot/150 sq.m of shopping floor area
slot/30 sq.m of customer area
slot/5 classrooms
slot/25 beds
slot/4 alleys
slot/50 sq.m of gross floor area
slot/100 sq.m of gross floor area
2.
3.
Special Provisions
3.1
1 parking slot for the handicapped per 50 up to 150 parking slots & an additional slot for every 100
slots thereafter.
3.2
Wheel chair transfer area one between 2 spaces, directly connect to accessible walk of travel and bldg
entrances.
3.3
Maximum distance of accessible parking area from facility served. Parking areas for handicapped shall be w/in
60m of the facility being served.
4.