Professional Documents
Culture Documents
Catalogo Difusores Metalaire
Catalogo Difusores Metalaire
P r o d u c t c ata l o g
The METALAIRE Ceiling Diffuser Catalog is designed to save you time selecting air distribution
equipment. The Ceiling Diffuser Catalog is divided into productlines. Each section begins with a
summary that includes all our available models along with features and benefits of our products.
To obtain product information not included in this catalog, simply go to our web site at
www.metalaire.com, or refer to our InfoSource catalogs.
At METALAIRE, we continually work to improve our products. Product descriptions, dimensions, and
performance are subject to change without notice. For the most current available literature visit our web page
at www.metalaire.com. Contact your local METALAIRE representative to verify product or performance details.
Table of Contents
RCD ROUND CEILING DIFFUSERS
RCD
DCD
P C D P e r f o r at e d C E I L I N G D I F F U S E R S
PCD
Table of Contents
PCD Perforated CEILING DIFFUSERS
(contd)
PCD
LSD
Series BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
PSD
Series LT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230
ARP
Modular Slot
ii
Table of Contents
EHD environmental/hospital DIFFUSERS
EHD
Environmental/Hospital Diffusers Radial Discharge Pattern Removable Face w/HEPA Filter Cell
E P P E n g i n e e r e d P o ly m e r P r o d u c t s
EPP
M D C M e ta l a i r e D i g i ta l C o n t r o l D i f f u s e r
MDC
UFD
3/2006
Model 900
Pg. 10
Model 3000
RCD
Pg. 14
3000-1 Flush
3000-2 Dropped
Model 3100
(Flush Face Shown)
Pg. 18
Series 3100 - Aluminum
Series 3100S - Steel
Steel
3100-1 Flush
3100-2 Dropped
3100S-1 Flush
3100S-2 Dropped
Model 3200
Excellent choice for high capacity applications such as factories, gymnasiums, theaters, and convention halls
Discharge pattern is easily adjusted from vertical to horizontal with adjustment ring
Diffuser can effectively be applied for either spot heating or cooling
In the horizontal setting the unit provides tight ceiling patterns excellent for VAV applications
Outer cone design guards against ceiling smudging in horizontal position
Pg. 22
Model R5750
Architectural pleasing round diffuser blends well into the ceiling surface
Fixed horizontal throw pattern
Designed for surface mounting applications
Excellent in both heating and cooling applications
The R5750 is an excellent choice for VAV applications
Pg. 26
RCD-8
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
RCD
Z
Mounting Screw
(3 Per Unit)
Diffuser Cone
Outer Mounting Cone
Damper Operator
Guide Hole
Y
A
Z
Mounting Screw
Diffuser Cone
Damper Operator
(Turn to Open or Close)
Diffuser Size
Number of Cones
Damper Size
7 7/8
2 3/16
11 7/8
2 13/16
5 7/8
10
14 1/8
9 7/8
14
RCD-10
10 1/8
12
Standard Finish:
01 White
Optional Finish
02 Aluminum
28 Custom Color
6
8
1. Available Finishes
12 1/8
16 1/8
18 1/8
13 7/8
1 7/8
2 1/2
3 1/8
10
14
12
2. Available Accessories
900D - Round Damper . . . . . . . . . . . . . . . . . . . . . . . . . . .335
Replacement Knobs
3
5
6
6 1/4
3. Construction Details
Sizes only as listed
3/2006
6"
8"
10"
12"
14"
fpm
200
300
400
500
600
700
800
900
1000
165
5-7
25
185
5-7
30
Pt
.005
.010
.015
.025
.035
.050
.065
.080
CFM
Throw
NC
65
4-6
<
100
4-6
<
135
4-6
<
165
5-7
20
200
5-8
25
230
5-8
25
265
5-8
28
300
5-9
30
330
6-10
35
150
5-8
<
230
5-9
<
305
6-10
20
685
6-16
35
760
10-18
35
CFM
Throw
NC
37
3-5
<
CFM
Throw
NC
105
4-7
<
CFM
Throw
NC
200
6-9
<
CFM
Throw
NC
55
3-5
<
160
5-8
<
310
7-11
<
75
3-6
<
90
3-6
<
110
4-6
20
415
8-13
20
520 625
730
830
935 1040
9-14 11-15 12-17 13-19 15-21 18-23
25
30
30
35
35
40
535
7-13
30
420
7-13
30
610
7-14
30
475
7-14
35
.10
265
5-10
20
455
6-12
25
370
6-12
30
145
4-6
25
210
5-9
<
380
6-11
25
315
6-11
25
130
4-6
23
525
7-14
35
RCD
Neck
Size
Diffuser Sizes
900D Models
X
5 15/16
Y
5 5/8
Z
3
10
9 15/16
9 5/8
12
14
7 15/16
11 15/16
13 15/16
7 5/8
11 5/8
13 5/8
4
6
7
RCD-11
3/2006
RCD
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
.8-1.0 mils
Film Cure
RCD-12
Performance
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Available Neck
Available Finishes
6" round
Standard
8" round
10
10" round
Optional
12
12" round
02 - Aluminum
14
14" round
01 - White
Available Options
900D
Aluminum Damper
EK
Extra Knots
RCD
RCD-13
3/2006
Overall Dia. C
Overall Dia. C
Ceiling Opening B
Neck Dia. A
3
4
Mounting Hole
(3 Per Unit)
3
4
Outer
Mounting
Cone
E
D (Full Open) Horizontal
Air Pattern
No. 2 Cone
No. 1 Cone
E
D (Full Open) Horizontal
Air Pattern
Gasket
No. 3 Cone
Ceiling Line
Damper Operator
Overall Dia. H
Overall Dia. H
Ceiling Opening G
Neck Dia. A
3
4
Optional
D-3 Damper
Mounting Hole
(3 Per Unit)
Optional
D-3 Damper
3
4
J
I (Full Open)
Horizontal
Air Pattern
No. 2 Cone
No. 1 Cone
Neck Size
Outer
Mounting
Cone
Ceiling Line
Damper Operator
5 7/8
12
13 1/2
2 1/4
1 5/8
2 3/4
10
9 7/8
20
22 1/2
2 15/16
2 5/8
28
31 1/2
4 1/4
36
40 1/2
40
45
12
7 7/8
11 7/8
14
13 7/8
18
17 7/8
16
20
24
RCD-14
Gasket
No. 3 Cone
J
I (Full Open)
Horizontal
Air Pattern
15 7/8
19 7/8
23 7/8
16
24
32
40
18
27
36
45
2 5/8
3 1/2
4 5/8
5
5 3/8
5 3/8
2 1/8
3 3/8
16 5/16
3 7/8
11
27 3/16
5 9/16
23 3/16
4 3/4
3 1/4
4 5/8
13
31 13/16
4 1/4
17
42 1/4
8 7/8
52 3/8
10 3/4
3 3/4
5 1/4
4 7/8
6 5/8
5 3/8
7 1/4
5 3/8
7 1/4
15
36 7/8
19
47 9/16
25
52 3/8
21
6 3/4
8
2 3/4
3 3/8
4
4 5/8
5 1/4
6
9 7/8
6 5/8
10 3/4
7 1/4
7 1/4
1. Available Finishes
2. Available Accessories
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
3. Available Options
Shipped Unattached
D3 - Aluminum Radial Opposed Blade Damper . .336
SD3 - Steel Radial Opposed Blade Damper . . . . . .336
G3 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . . . . .337
GD3 - Combination Grid/Damper . . . . . . . . . . . . . . . .337
BDS - Butterfly Damper . . . . . . . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter Damper . . . . . . . . . . . . . . . .336
Safety Chain
4. Construction Details
Sizes only as listed
3/2006
6"
0.2
8"
0.35
10"
0.55
12"
0.79
14"
1.07
16"
1.4
18"
1.77
20"
2.18
24"
3.14
400
500
0.01
600
700
800
0.04
900
1000
0.051 0.063
1200
1400
1600
0.09
0.122
0.16
240
4-9
36
280
5-10
39
320
6-12
44
655
7-14
37
765
8-18
40
870
9-21
45
Ps Horiz. 0.011 0.018 0.026 0.035 0.046 0.059 0.072 0.105 0.145 0.190
Ps Vert. 0.019 0.03 0.043 0.058 0.075 0.096 0.115 0.17 0.225 0.3
CFM
Throw
NC
80
1-3
<
100
2-4
<
220
2-5
<
270
3-6
<
CFM
Throw
NC
140
2-4
<
CFM
Throw
NC
315
3-7
<
CFM
Throw
NC
CFM
Throw
NC
CFM
Throw
NC
CFM
Throw
NC
CFM
Throw
NC
110
2-5
<
140
3-6
20
160
3-7
24
330
3-7
<
380
4-8
21
435
5-10
25
640
5-11
20
750
6-13
23
855
7-16
27
1060
6-15
21
1240
7-17
25
175
2-5
<
210
3-6
<
390
3-8
<
470
4-10
20
560
4-9
<
700
5-10
<
840
5-13
21
875
4-11
<
1090
6-14
20
425
3-8
<
535
4-9
<
710
4-10
<
885
5-12
<
1310
7-16
22
245
3-7
20
550
5-11
22
980
6-15
24
1525
8-19
26
180
3-8
27
280
4-8
24
315
4-10
27
630
6-13
26
710
7-15
29
1120
7-17
28
1260
9-21
33
1420
9-21
29
1745
9-23
30
200
4-8
36
350
5-11
31
420
5-13
36
785
8-17
33
940
9-19
38
490
6-11
28
545
6-12
32
965
8-18
31
1070
9-20
34
490
6-14
39
RCD
560
7-16
44
1100 1260
10-21 12-25
41
46
CFM 1255 1570 1885 2200 2510 2825 3140 3770 4395 5025
Throw 12-24 13-26 14-28 15-30 16-33 17-35 18-37 20-40 23-45 25-50
NC 22
26
28
31
35
38
41
47
51
55
0 dB
4 dB
8 dB
16 dB
Factor Times
Listed Pt (2)*
1.0
1.5
2.0
4.0
RCD-15
3/2006
Performance Specification
RCD
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
.8-1.0 mils
Film Cure
RCD-16
Performance
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Model
3000-1 - Flush Mount
3000-2 - Drop Face
Available Finishes
6" round
8" round
Standard
10
10" round
Optional
12
12" round
14
Available Options
D3
SD3
G3
02 - Aluminum
GD3
Combo Grid/Damper
14" round
24 - Mill
BDS
Butterfly Damper
16
16" round
03 - Black
RSD
18
18" round
28 - Custom Color
20
20" round
24
24" round
01 - White
SC
Safety Chain
Available Accessories
RCD
RCD-17
3/2006
RCD
Outer
Cone
No. 2 Cone
Outer
Cone
Neck Diameter A
No. 2 Cone
Overall Diameter B
Outer
Cone
G
E
Neck Diameter A
No. 1 Cone
Closed Position
No. 2 Cone
Overall Diameter B
Overall Diameter B
Dimensions
D
5 3/4
16 5/8
2 15/16
11
1 1/4
5/8
3/4
1 7/8
10
9 3/4
22 3/16
3 5/16
17
1 1/4
7/8
3/4
2 1/2
14
13 3/4
29 1/4
4 3/16
22
18
17 3/4
12
16
20
24
30
36
7 3/4
11 3/4
15 3/4
19 3/4
23 3/4
29 3/4
35 3/4
16 5/8
22 3/16
29 1/4
34 1/2
34 /12
40 1/2
49 1/2
58 3/8
2 15/16
3 5/16
4 3/16
4 5/8
4 5/8
5 1/4
6 1/8
7 1/8
11
17
22
27
27
34
41
50
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
2 1/4
2 1/4
5/8
7/8
3/4
3/4
7/8
1 9/16
1 9/16
7/8
1
1
1 3/8
1 3/8
1 9/16
1 9/16
1 9/16
2 1/16
2 1/16
1 7/8
2 1/2
3 1/2
3 3/8
3 3/4
3 3/4
4 1/4
5 1/8
6 1/8
RCD-18
No. 1 Cone
Closed Position
Size
No. 1 Cone
No. 2 Cone
Overall Diameter B
Outer
Cone
No. 1 Cone
Neck Diameter A
Mounting
Tabs
1. Available Finishes
Control Rod
Dimensions
Size
A
2 1/2
6
3 1/2
8
10 4 1/2
12 5 1/2
14 6 1/2
16 7 1/2
Control Rod
2. Available Accessories
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
Mounting
Tabs
4. Construction Details
3. Available Options
Shipped Unattached
D3 - Aluminum Radial Opposed Blade Damper . .336
SD3 - Steel Radial Opposed Blade Damper . . . . . .336
G3 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . .337
GD3 - Combination Grid/Damper . . . . . . . . . . . . .337
BDS - Butterfly Damper . . . . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter Damper . . . . . . . . . . . . . . . .336
Dimensions
Size
A
2 1/2
6
3 1/2
8
10 4 1/2
12 5 1/2
14 6 1/2
16 7 1/2
Safety Chain
RCD
3/2006
6"
0.188
8"
0.338
10"
0.769
12"
1.05
14"
1.375
16"
1.743
18"
2.154
20"
3.109
24"
3.109
30"
4.868
36"
7.02
400
500
600
700
0.01
0.016
0.023
0.031
75
2-3-6
<18
94
3-4-8
<18
113
3-5-9
<18
188
5-8-16
26
372
5-8-17
26
425
6-9-18
29
479
7-10-20
31
840
8-13-25
34
945
9-14-28
37
1050
10-15-30
39
1260
12-18-36
44
1743
14-20-43
41
2091
16-24-48
46
203
4-6-12
19
237
4-7-13
20
308
5-7-15
19
385
5-8-16
22
461
6-9-18
25
538
7-10-20
28
825
8-12-25
30
962
9-14-27
32
CFM
Throw
NC
420
6-9-18
22
525
6-10-19
25
697
8-12-24
25
871
9-13-27
28
1046
110-15-32
31
1554
13-20-40
31
1885
15-22-45
33
3510
27-40-81
33
4212
30-45-90
36
CFM
Throw
NC
CFM
Throw
NC
550
7-10-21
24
CFM
Throw
NC
862
9-13-27
27
1077
10-15-30
30
1947
17-26-51
30
2434
19-29-54
32
CFM
Throw
NC
CFM
Throw
NC
1224
12-18-36
28
CFM
Throw
NC
2808
24-36-72
31
CFM
Throw
NC
687
7-11-22
27
630
7-11-21
28
0.225
0.44
169
5-7-14
23
169
3-5-10
19
319
5-7-15
23
0.156
0.305
151
4-6-12
19
135
3-5-9
19
213
4-16-12
<18
1200
132
4-5-11
18
CFM
Throw
NC
CFM
Throw
NC
1000
0.063
0.025
0.049
266
4-7-13
20
0.056
0.109
900
0.051
Ps Horiz.
Ps Vert.
CFM
Throw
NC
0.039
0.076
800
0.04
0.076
0.149
735
8-12-23
31
0.1
0.194
271
5-8-15
24
615
7-11-22
31
1100
10-15-30
35
0.126
0.247
4914
33-49-99
38
301
9-13-26
40
692
8-12-24
34
769
9-13-26
37
923
11-16-32
42
1077
12-19-37
47
1231
14-21-43
51
1649
14-22-43
45
1924
17-25-50
50
2194
19-29-57
54
1237
11-17-33
38
2798
20-30-59
40
3894
26-39-78
39
264
7-11-22
36
541
10-15-30
46
2487
18-27-54
38
3408
24-35-71
37
226
6-9-19
32
0.16
474
10-14-29
42
2176
16-25-49
36
2921
21-32-64
35
0.398
0.777
406
8-12-25
37
1568
13-19-38
39
1724
13-20-39
37
0.304
0.594
338
7-10-20
31
1394
12-17-35
36
1508
12-18-36
35
1600
0.122
304
6-9-17
28
1220
11-16-32
33
1293
11-16-32
32
1400
0.09
1939
14-22-43
39
4381
28-42-85
41
532
7-11-23
34
1375
12-18-37
40
2154
16-24-47
41
3109
21-32-64
42
4868
31-46-92
43
638
9-14-27
40
2585
19-28-56
45
3731
25-37-75
46
745
11-16-32
45
1470
14-21-43
48
2440
18-28-55
50
3016
22-33-65
50
4353
28-42-84
50
851
12-18-36
49
1680
17-25-57
52
2788
21-32-64
54
3447
24-36-72
54
4974
31-47-93
54
5842
6815
7789
35-53-105 39-58-117 42-63-126
47
51
54
5616
6318
7020
8423
9827
11231
36-54-108 39-59-118 42-63-127 48-72-144 53-79-158 58-84-168
40
42
44
48
57
54
RCD-19
RCD
3/2006
Performance Notes:
1. Tabulated throw in feet is based on a 9 ceiling, with supply air temperature 20F cooler than room temperature, MAX Throw @ Vt = 50 fpm, MIN
Throw @ Vt = 150 fpm, and the diffuser/inner cones in down position for 360 horizontal air distribution pattern.
Example: 9-13-27
.....Distance @ 50 fpm Term. Vel.
.....Distance @ 100 fpm Term. Vel.
.....Distance @ 150 fpm Term. Vel.
For vertical Ak values, multiply Ak by 0.76.
2. For vertical down projection air pattern with cooling supply air temperature 20 below room temperature, and diffuser inner cones in up position:
multiply the tabulated radial throw values by a factor of 0.80 to obtain vertical down projection distances at MIN and MAX (Vt) terminal velocities.
3. For vertical down projection air pattern with heating supply air temperatures 20 above room temperature, and diffuser inner cones in up position:
multiply the tabulated radial throw values by a factor of 0.60 to obtain vertical down projection distances at MIN and MAX (Vt) terminal velocities.
4. Velocity Pressure (Pv) and Static Pressure (Ps) are in inches of water. Pv + Ps = Pt (total pressure).
5. Series 3100 Round Adjustable Diffusers are tested in accordance with ASHRAE 70-1991. Sound data are calculated in accordance with International
Standard ISO 3741 comparison method. The NC values are based on a room absorption of 10 dB for sound power level (Lw) RE: 10E-12 watts.
< symbol indicates NC less than 20. The NC data is for a single diffusers; for results of throttling a volume damper, see table below.
6. All data is applicable for exposed duct mounting or ceiling installation.
100%
0 dB
1.0
82%
4 dB
1.5
70%
8 dB
2.0
50%
16 dB
4.0
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
RCD-20
3/2006
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
RCD
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Paint Specification
Available Finishes
3100-1 - Fixed
6" round
Standard
3100A-1 - Adjustable
8" round
3100-2 - Fixed
10
10" round
3100A-2 - Adjustable
12
12" round
02 - Aluminum
14
14" round
16
18
20
20" round
24
24" round
30
30" round
36
36" round
Available Options
SC
Safety Chain
Available Accessories
D3
SD3
G3
GD3
Combo Grid/Damper
24 - Mill
BDS
Butterfly Damper
16" round
03 - Black
RSD
18" round
28 - Custom Color
01 - White
Optional
Available Finishes
3100S-1 - Fixed
6" round
Standard
3100S-A-1 - Adjustable
8" round
3100S-2 - Fixed
10
10" round
Optional
3100S-A-2 - Adjustable
12
12" round
02 - Aluminum
14
14" round
16
16" round
18
18" round
20
20" round
24
24" round
30
30" round
36
36" round
Available Options
Safety Chain
Available Accessories
D3
SD3
G3
GD3
Combo Grid/Damper
03 - Black
BDS
Butterfly Damper
28 - Custom Color
RSD
01 - White
SC
RCD-21
3/2006
RCD
Model 3200-1
Standard Finish: 01 White
Round Diffuser - High Capacity - Adjustable - Pole Operated - Vertical to Horizontal Pattern
Model 3200-1
Outer
Cone
E
F
Overall Diameter B
5 3/4
17 1/4
2 1/8
D
6 3/4
E
1 1/8
F
1 1/8
10
9 3/4
20 1/4
2 5/8
10 3/4
1 1/4
1 3/4
2 5/8
14 3/4
12
11 3/4
18
17 3/4
24
RCD-22
7 3/4
13 3/4
20
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
14
16
1. Available Finishes
Dimensions
Size
15 3/4
19 3/4
23 3/4
17 1/4
22 1/4
29 1/2
29 1/2
33 1/2
36 /12
40 1/2
2 1/8
2 5/8
2 3/4
3 5/8
3 5/8
3 5/8
2. Available Accessories
G3 - Equalizing Grid . . . . . . . . . . . . . . . .337
8 3/4
12 3/4
16 3/4
18 3/4
20 3/4
24 3/4
1 1/8
1 1/4
1 1/4
1 1/4
1 1/4
1
1
1 1/4
1 3/4
2 3/8
2 3/8
2 1/2
2 1/2
2 1/2
3. Available Options
Safety Chain
4. Construction Details
Sizes only as listed
Units 14" and greater are shipped with a
factory installed safety chain
3/2006
6"
Dia
8"
Dia
10"
Dia
12"
Dia
14"
Dia
16"
Dia
400
0.010
80
0.004
0.014
0.020
0.030
<
<
113
248
013
325
0.006
0.029
0.026
0.049
17
<
236
71021
247
535
0.004
0.020
0.017
0.033
16
15
247
2521
137
640
0.006
0.029
0.024
0.047
21
19
349
3728
248
315
0.003
0.013
0.011
0.021
<
<
225
4817
126
395
0.004
0.02
0.017
0.033
<
<
236
71021
137
560
0.003
0.013
0.010
0.02
15
16
237
2414
126
700
0.004
0.020
0.016
0.032
20
20
348
3623
138
430
0.003
0.013
0.011
0.021
<
<
236
1313
125
275
0.004
0.020
0.018
0.034
16
<
235
6918
136
175
0.004
0.020
0.018
0.034
16
<
124
5714
125
220
0.003
0.013
0.012
0.022
<
<
124
4714
125
600
0.022
120
0.010
0.032
0.046
0.068
15
<
124
4613
124
140
0.003
0.013
0.012
0.022
<
<
123
3611
114
500
0.016
100
0.007
0.022
0.032
0.047
<
<
123
4511
124
700
0.031
135
0.013
0.044
0.062
0.093
16
13
124
5714
125
800
0.040
155
0.017
0.057
0.081
0.121
17
15
225
5816
236
490
0.014
0.065
0.059
0.109
22
15
359
101631
4511
960
0.014
0.065
0.055
0.105
32
30
4613
71743
4612
245
0.009
0.039
0.036
0.066
20
<
236
61019
237
470
0.006
0.029
0.025
0.047
15
<
247
81225
248
550
0.009
0.039
0.034
0.064
19
17
349
101529
3510
630
0.011
0.051
0.044
0.084
23
20
3510
111733
4611
705
0.014
0.065
0.056
0.106
26
23
4611
121937
4613
840
0.006
0.029
0.024
0.046
25
24
3510
4830
249
975
0.009
0.039
0.032
0.063
29
28
4612
51135
2511
1115
0.011
0.051
0.042
0.082
33
31
4713
61440
3612
1255
0.014
0.065
0.053
0.104
37
35
5715
81845
4714
750
0.009
0.039
0.033
0.064
25
23
3510
51033
359
435
0.011
0.051
0.046
0.086
20
<
348
91428
359
855
0.011
0.051
0.043
0.083
29
27
4612
61338
4511
1000
0.062
195
0.027
0.089
0.127
0.189
21
18
236
71021
247
210
0.006
0.029
0.026
0.049
18
<
225
6817
136
380
0.009
0.039
0.036
0.066
19
<
247
81224
248
280
0.011
0.051
0.046
0.086
21
<
237
71122
348
900
0.050
175
0.022
0.072
0.103
0.153
19
16
236
6919
236
315
0.014
0.065
0.059
0.109
23
17
247
81325
349
1200
1400
0.090
235
0.039
0.128
0.182
0.272
24
22
247
81225
348
0.122
275
0.052
0.175
0.248
0.371
26
25
349
101529
3510
545
0.018
0.080
0.073
0.135
23
17
3510
121735
4612
655
0.026
0.115
0.104
0.194
26
23
4612
142142
5714
765
0.035
0.157
0.142
0.264
29
27
5714
162449
6817
1070
0.018
0.080
0.068
0.13
36
33
5714
92148
4713
1285
0.026
0.115
0.097
0.187
41
38
6917
132957
5816
350
0.018
0.080
0.073
0.135
25
19
348
91428
359
785
0.018
0.080
0.069
0.131
29
27
4612
142142
5714
1395
0.018
0.080
0.066
0.128
40
38
6817
102250
5816
420
0.026
0.115
0.104
0.194
28
24
3510
111733
4611
940
0.026
0.115
0.099
0.188
35
32
5715
172550
6817
1675
0.026
0.115
0.094
0.184
45
43
71020
143060
6919
1600
0.160
315
0.069
0.228
0.324
0.484
29
29
359
111733
4611
490
0.035
0.157
0.142
0.264
31
28
4612
131939
4713
560
0.046
0.205
0.186
0.345
34
32
4712
152245
5815
1100
0.035
0.157
0.134
0.257
40
37
6917
192958
71020
1255
0.046
0.205
0.175
0.335
43
41
71019
223367
81123
1955
0.035
0.157
0.129
0.251
48
47
81223
203569
71122
2235
0.046
0.205
0.168
0.328
50
49
91325
264079
81225
1495
0.035
0.157
0.133
0.255
44
42
71020
183367
6919
RCD
Neck Velocity
Velocity Pressure
Air Flow Rate, CFM
Static Pressure, H
Total Pressure, H
Static Pressure, V
Total Pressure, V
NC, H
NC, V
Throw, H, cooling
Throw, V, cooling
Throw, V, heating
875
0.046
0.205
0.186
0.345
32
31
6815
192856
6919
1710
0.046
0.205
0.173
0.333
46
45
81222
243871
71122
RCD-23
3/2006
RCD
Velocity Pressure
18"
Dia
20"
Dia
24"
Dia
400
0.010
705
0.003
0.013
0.01
0.02
<
<
247
2414
115
1255
0.002
0.012
0.009
0.019
<
<
3510
2417
115
875
0.003
0.013
0.01
0.02
<
<
348
2414
014
500
0.016
600
0.022
700
0.031
800
0.040
900
0.050
1000
0.062
1200
0.090
1400
0.122
1600
0.160
885
0.004
0.02
0.016
0.031
19
16
359
3623
128
1060
0.006
0.029
0.023
0.045
23
21
4611
4832
1311
1235
0.009
0.039
0.031
0.062
27
25
4713
51137
2412
1415
0.011
0.051
0.041
0.081
31
30
5715
61443
2514
1590
0.014
0.065
0.051
0.102
35
34
6817
81848
3616
1765
0.018
0.08
0.064
0.126
38
37
6919
102353
4818
2120
0.026
0.115
0.092
0.181
44
43
71122
143264
51121
2475
0.035
0.157
0.125
0.247
50
49
913 26
20 3774
71225
2825
0.046
0.205
0.163
0.322
54
52
101528
26 4385
91428
1570
0.004
0.019
0.014
0.03
19
17
4612
3727
127
1885
0.005
0.028
0.021
0.043
25
23
5715
41038
1310
2200
0.007
0.038
0.028
0.059
31
28
6917
61350
2314
2515
0.009
0.049
0.037
0.077
36
32
71020
81757
2518
2825
0.012
0.062
0.047
0.097
40
37
71122
102164
3621
3140
0.015
0.077
0.058
0.12
44
40
81225
122771
3723
3770
0.021
0.111
0.083
0.173
50
47
101530
173885
51028
4400
0.029
0.151
0.113
0.236
54
52
121735
235099
61433
5025
0.038
0.197
0.148
0.308
56
56
132037
3057109
81837
1090
0.004
0.02
0.015
0.031
19
<
3510
2622
116
1310
0.006
0.029
0.022
0.044
25
20
4612
4832
129
1525
0.009
0.039
0.029
0.06
29
25
5714
51141
1312
1745
0.011
0.051
0.038
0.078
34
30
6817
61447
2415
1965
0.014
0.065
0.049
0.099
38
35
6919
81853
2518
2180
0.018
0.08
0.06
0.123
41
39
71021
102259
3619
2620
0.026
0.115
0.087
0.176
48
45
81225
143271
4923
3055
0.035
0.157
0.118
0.24
53
50
101429
194183
51227
3490
0.046
0.205
0.154
0.314
57
52
111731
254795
71531
RCD-24
3/2006
Air outlets shall be model 3200 manufactured by METALAIRE. Diffusers shall be constructed of an opposed blade damper inner assembly mounted in an
inner ring. Outlets shall allow the adjustment of the discharge pattern from full horizontal to full vertical and be adjustable from the face by turning an
operator ring. Units shall be steel construction. The units shall be the size and quantity as outline in the plans and specifications.
Pattern adjustment operator shall open the inner opposed blade damper assembly to discharge the air in a vertical pattern or close the damper to allow a
tight horizontal pattern. In the horizontal setting, core shall project discharge pattern to minimize ceiling smudging. The inner core assembly shall be
removable for installation and for access into the ductwork.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
RCD
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
6" round
Available Finishes
Standard
8" round
10
10" round
12
12" round
02 - Aluminum
14
14" round
03 - Black
16
16" round
28 - Custom Color
18
18" round
20
20" round
24
24" round
Available Options
SC
Safety Chain
Available Accessories
G3
01 - White
Optional
RCD-25
RCD
3/2006
Model R5750
Standard Finish: 01 White
Dimensions are in inches
Round Diffusers
Aluminum / Steel Construction - Fixed Horizontal Pattern
Model R5750-S - All Steel Construction
Model R5750-AL - All Aluminum Construction
Model R5750-AF - Steel Backpan - Aluminum Face
Outer Cone
E
Overall Diameter B
Nominal
Round
Duct Size
Dim.
A
7 3/4
10
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
RCD-26
16 5/8
9 3/4
22 3/16
12
11 3/4
16
15 3/4
14
Dim.
B
5 3/4
13 3/4
16 5/8
Dim.
C
2 15/16
2 15/16
3 5/16
Dim.
D
Dim.
E
Dim.
F
Dim.
G
Dim.
H
11
3/4
5/8
3/4
14
7/8
11
17
22 3/16
3 5/16
17
29 1/4
4 3/16
22
29 1/4
4 3/16
22
2. Available Accessories
D3 - Aluminum Radial Opposed Blade Damper . .336
SD3 - Steel Radial Opposed Blade Damper . . . . . .336
GD3 - Combination Grid/Damper . . . . . . . . . . . . .337
BDS - Steel Butterfly Damper . . . . . . . . . . . . . . . .337
RSD - Radial Shutter Damper . . . . . . . . . . . . . . . .336
G3 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . .337
3/4
1.0
1.0
1.0
1.0
5/8
7/8
14
7/8
19
7/8
7/8
19
3/4
7/8
7/8
7/8
3. Available Options
Safety Chain
4. Construction Details
Sizes only as listed
3/2006
10
12
14
16
Nk Velocity
Pv
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
400
0.015
79
0.023
0.038
- 2 <15
140
0.024
0.039
- 2 <15
218
0.026
0.041
- 4 <15
314
0.035
0.050
- 5 <15
428
0.025
0.040
- 6 <15
559
0.038
0.053
- 7 19
11 4
12 5
13 6
500
0.024
98
0.035
0.059
- 3 <15
175
0.037
0.061
- 3 16
273
0.040
0.064
- 6 <15
393
0.054
0.078
- 7 <15
535
0.038
0.062
- 7 <15
698
0.058
0.082
- 8 19
2 -
2 -
4 -
12 5 -
12 6 -
13 7 -
600
0.034
118
0.052
0.086
3 19
209
0.054
0.088
3 21
327
0.058
0.092
7 <15
471
0.078
0.112
8 <15
641
0.055
0.089
9 22
838
0.084
0.118
10 24
11
13
13
15
700
0.046
137
0.070
0.116
- 3 24
244
0.074
0.120
- 4 26
382
0.080
0.126
- 8 24
550
0.106
0.152
- 9 26
748
0.075
0.121
- 10 23
977
0.114
0.160
- 12 26
13
14
16
18
800
0.060
157
0.092
0.152
- 4 29
279
0.096
0.156
- 4 31
436
0.104
0.164
- 9 28
628
0.139
0.199
- 11 29
855
0.098
0.158
- 12 25
1117
0.149
0.209
- 13 32
14
16
17
19
900
0.076
177
0.117
0.193
3 - 4 31
314
0.122
0.198
3 - 5 33
491
0.132
0.208
7 - 10 32
707
0.175
0.251
8 - 12 34
962
0.124
0.200
9 - 13 26
1257
0.187
0.263
10 - 15 33
1000
0.094
196
0.143
0.237
8 3 - 5 34
349
0.150
0.244
10 4 - 6 35
545
0.162
0.256
16 7 - 11 35
785
0.216
0.310
19 9 - 13 36
1069
0.153
0.247
19 10 - 15 29
1396
0.230
0.324
21 11 - 17 34
1200
0.136
236
0.208
0.344
9 4 - 6 38
419
0.216
0.352
11 4 - 7 40
654
0.233
0.369
18 9 - 13 41
942
0.311
0.447
21 11 - 16 43
1283
0.220
0.356
21 12 - 18 33
1676
0.328
0.464
23 13 - 20 37
11
13
21
22
RCD
Neck Size
21
24
Performance Notes:
All data are tested in accordance with ANSI/ASHRAE 70-1991
Definition of Units:
CFM - Cubic feet per minute (air)
Nk Vel - Neck velocity of air stream in feet per minute
Pv - Velocity pressure (inches of water column)
Pt - Total pressure (inches of water column)
Ps - Static pressure = Pt - Pv (inches of water column)
Throw - Isothermal horizontal throw (supply air temperature the same as average room air temperature)
values are for 150 fpm - 100 fpm - 50 fpm velocities, respectively
NC - Noise criterion, sound pressure level. NC ratings are based on sound power level (Lw) RE: 10E-12
watts minus a 10 dB room attenuation in all octave bands
RCD-27
3/2006
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
RCD
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
Available Finishes
R5750-AL
6" round
R5750-S
8" round
10
10" round
12
12" round
02 - Aluminum
14
14" round
16
16" round
RCD-28
Standard
Available Options
SD3
G3
GD3
03 - Black
BDS
28 - Custom Color
RSD
Optional
Safety Chain
Available Accessories
D3
01 - White
SC
D
D
C
C
D
D
DIRECTIONAL
DIRECTIONAL
CEILING DIFFUSERS
CEILING DIFFUSERS
Model 5000
Available in 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way directional air patterns
Cores are easy to remove with spring loaded latches no tools required
Series 5000 deflector blades are straight and do not include a horizontal lip, making this diffuser
an excellent choice for high capacity applications
The series 5000 is an excellent choice for VAV applications
The series 5000 is available with optional induction vanes
Aluminum
(Border 1
Surface Mount Shown)
Pg. 34
5000-6
5000-7
5000-8
5000-9
T-bar Lay-in
Concealed T-bar
Tegular T-bar
Donn Fineline
Straight Lip
DCD
Model 5500
Aluminum
(Border 6
T-bar Lay-in Shown)
Pg. 46
Available in 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way directional air patterns
Cores are easy to remove with spring loaded latches no tools required
Series 5500 deflector blades include a horizontal lip, making this diffuser an excellent choice for
high induction applications
The series 5500 is an excellent choice for VAV applications
The series 5500 is available with optional induction vanes
Available Border Styles
5500-6
5500-7
5500-8
5500-9
T-bar Lay-in
Concealed T-bar
Tegular T-bar
Donn Fineline
Horizontal Lip
Model 5500S
Steel
Available in 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way directional air patterns
Cores are easy to remove with spring loaded latches no tools required
Series 5500S deflector blades include a horizontal lip, making this diffuser an excellent choice
for high induction applications
The series 5500S is an excellent choice for VAV applications
The series 5500S is also available with optional induction vanes.
(Border 6
T-bar Lay-in Shown)
Pg. 48
5500S-1
5500S-2
5500S-6
5500S-8
5500S-9
Surface Mount
V-Beveled Drop Surface Mounting
T-bar Lay-in
Tegular T-bar
Donn Fineline
5500SR-1
5500SR-2
5500SR-6
5500SR-8
5500SR-9
Horizontal Lip
Model 5200
Pg. 58
DCD-30
3/2006
3/2006
Pg. 62
Series 5700 - Fixed
Series 5700A - Adjustable
Steel
5700-1 Surface Mount
5700-6 T-bar Lay-in
5700-6P T-bar Lay-in Panel
5700-7 Concealed T-bar
5700-9 Donn Fineline
Aluminized Steel
Adjustable/Steel
Adjustable/Aluminized Steel
5700A-1 AS Surface Mount
5700A-6 AS T-bar Lay-in
5700A-7 AS Concealed T-bar
Adjustable/Aluminum
5700A-6 AL T-bar Lay-in
Metric/Steel
M5700-6 T-bar Lay-in
600mm x 600mm
Aluminum
Metric/Aluminized Steel
M5700-6 AS T-bar Lay-in
600mm x 600mm
DCD
Model 5700
The series 5700 provides a tight horizontal 360 discharge pattern for superior induction and
occupant comfort
Series 5700 can be converted in the field to a 3 cone diffuser with the addition of the optional Snap-58
Lay-in border designed to be installed in standard 15/16 wide tees
T-bar Lay-in border 6 can be used in surface mounting applications by adding optional
T-bar plaster frame (TBPF)
Cores are easy to remove without tools
The series 5700 is an excellent choice for VAV applications
Metric/Aluminum
M5700-6 AL T-bar Lay-in
600mm x 600mm
Square Panel Face Diffusers - Round Neck - Uni-Flo - Steel/Aluminized Steel - Series 5750
Model 5750
Pg. 68
Steel
5750-1 Surface Mount
5750-6 T-bar Lay-in
5750-7 Concealed T-bar
5750-9 Donn Fineline
Metric/Steel
Aluminized Steel
5750-1 AS
5750-6 AS
5750-7 AS
5750-9 AS
Surface Mount
T-bar Lay-in
Concealed T-bar
Donn Fineline
Metric/Aluminized Steel
M5750-6 AS T-bar Lay-in 600mm x 600mm
Model 5800
The series 5800 provides a tight 360 discharge pattern for superior induction and occupant comfort
T-bar Lay-in border type 6 is designed to be installed in standard 15/16 wide tees
border type 6 can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Cores are easy to remove without tools
The Series 5800 is an excellent choice for VAV applications
Pg. 74
Steel
Aluminized Steel
5800-1 AS Surface Mount
5800-6 AS T-bar Lay-in
Aluminum
5800-1 AL Surface Mount
5800-6 AL T-bar Lay-in
Adjustable/Steel
5800A-1 Surface Mount
5800A-6 T-bar Lay-in
Adjustable/Aluminized Steel
5800A-1 AS Surface Mount
5800A-6 AS T-bar Lay-in
Metric/Aluminum
M5800-6 AL T-bar Lay-in
600mm x 600mm
DCD-31
3/2006
Square Panel Face Diffusers - Round Neck - Ultra High Performance - Series Phenomenator
The highest induction ratio of any commercial air diffuser available
Excellent selection for providing exceptional comfort, especially in executive offices, conference
rooms, and board rooms
Can improve productivity by maintaining draft-free comfort in many applications
Designed for applications calling for minimal temperature differences in a space
Solves comfort problems in applications such as reception areas and entrance ways
Diffuser can be applied in critical applications requiring minimal temperature gradients
Series
Phenomenator
Pg. 80
Steel
Phenom-1
Phenom-6
Phenom-7
Phenom-9
Aluminized Steel
Surface Mount
T-bar Lay-in
Concealed T-bar
Donn Fineline
Phenom-1 AS
Phenom-6 AS
Phenom-7 AS
Phenom-9 AS
Surface Mount
T-bar Lay-in
Concealed T-bar
Donn Fineline
Metric/Steel
M-Phenom-6 T-bar Lay-in 600mm x 600mm
Metric/Aluminized Steel
M-Phenom-6 AS T-bar Lay-in 600mm x 600mm
DCD
Concentric Supply/Return Ceiling Diffusers - Louvered Face - Cube Core Series 5500 DAF-CC5
Model
5500 DAF-CC5
5500 DAF-CC5 concentric supply/return diffuser is designed for high capacity application
Cube core return
4-way air patterns only
Choice of 6 mounting frames
Snap-in/out core - simplifies installation
Sizes to handle full range of standard tonnage roof-top units
Supply/Return plenums are by others
Pg. 84
5500 DAF-CC5-1
5500 DAF-CC5-2
5500 DAF-CC5-4
5500 DAF-CC5-6
5500 DAF-CC5-7
5500 DAF-CC5-8
Surface Mount
V-Beveled Drop Surface Mounting
Deep Drop Frame
T-bar Lay-in
Concealed T-bar
Tegular T-bar Lay-in
Square/Rectangular Diffusers - Modular Core - Supply - Extruded Aluminum - Series 9000 Mod-Flo
The series 9000 is a directional ceiling diffuser available in a wide range of field capabilities
Modular cores can be adjusted to obtain 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way air patterns
Cores are easy to remove with spring loaded latches - no tools required
T-bar Lay-in border type 6 can be used in surface mounting applications by adding optional
T-bar plaster frame (TBPF)
The series 9000 is an excellent choice for VAV applications
Model 9000
Pg. 94
Available Styles
9000-1
9000-2
9000-6
9000-7
9000-8
9000-9
DCD-32
Surface Mount
Beveled Frame
T-bar Lay-in
Concealed Spline
Tegular T-bar
Donn Fineline
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
DCD
1
14
13
16
1
12
1
12
3
16
Overall diffuser = Neck Size + 5 3/4
1
18
1
14
23
8
1
12
1
Overall Diffuser = Listed size + 5 8
1
Overall Diffuser = Modual - 4
1
Ceiling Opening = Listed Size + 2
1
Neck Size = Listed Size - 8
1
22
13
16
3
4
DCD-34
1
Neck Size = Listed Size - 8
11
1 16
1
22
T-Bar Grid
T-bar
1
12
Ceiling
Line
1
12
3
4
1
Neck Size = Listed Size - 8
Concealed T-Bar
(2) Kerfs
1
12
1
Overall Panel = T-Bar Spacing - 4
T-Bar Module =
(12 x 12, 24 x 24, 36 x 24, 48 x 24 and 48 x 48 )
11
1 16
1
Neck Size = Listed Size - 8
1
12
1
Overall Panel = T-Bar Module - 16
T-Bar Module = 24 x 24
1 15
16 *
1
12
3
Overall Diffuser = 23 3
4 x 23 4
1
Duct Opening = Listed Size - 8
(Maximum 15 x 15)
3
8
11 *
1 16
7
22 7
8 x 22 8 Overall Face
1
Overall Diffuser = T-Bar Spacing - 4
11
T-Bar Module = 24 x 24
3
23 3
8 x 23 8
3/2006
S1 - One Way
S3 - Three Way
DCD
Duct Size - 85
Optional D5
Opposed Blade Damper
23
8
3
3
16
1
12
IV Induction Vane
-Available for all 5000 series borders and sizes.
-Cannot be used with APD option.
-IV Induction Vanes are factory mounted.
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
Note:
Anodized Finish not available
2. Available Accessories
Square and Rectangular Neck:
D5 - Opposed Blade Damper- Steel . . . . . . . . . . . . . .337
D5A - Opposed Blade Damper- Aluminum . . . . . . . . .337
L9 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . . . . .334
TR - Square to Round Transition . . . . . . . . . . . . . . . .338
TR DEEP - Square to Round Transition - Deep . . . . . . . .338
Round Neck:
G3 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . . . . .337
BDS - Butterfly Damper . . . . . . . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter Damper . . . . . . . . . . . . . . . . . . .336
3. Available Options
Factory Mounted:
IV - Induction Vanes
APD - Air Pattern Deflectors allows
adjustment from horizontal to vertical air
pattern from the face of the diffuser
4. Construction Details
Available air patterns:
S1, S2, S3, S4, R1S, R1L, R2S, R2L,
R3S, R3L, R4 and SC
For 5000-6 (D5) models only:
21" x 21" neck in 24" x 24" module is
available in S4 pattern only
Note:
IV (Induction Vanes) can not be used
with APD (Air Pattern Deflector) option
and vice-versa
DCD-35
DCD
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
NECK SIZE
Ak
6" X 6"
Ak = .145
9" X 9"
Ak = .325
12" X 12"
Ak = .578
15" X 15"
Ak = .903
18" X 18"
Ak = 1.301
21" X 21"
Ak = 1.77
24" X 24"
Ak = 2.312
27" X 27"
Ak = 2.926
33" X 33"
Ak = 4.371
Ps
Pt
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
200
300
169
42
5-9
-
225
56
8-12
-
281
70
10-15
21
335
84
12-17
26
313
78
4-8
-
469
117
7-12
-
625
156
10-15
21
781
195
12-18
26
938
234
15-20
31
1094
273
17-22
36
613
153
6-12
-
919
230
9-16
-
1225
306
12-19
23
1531
383
15-21
28
1837
459
17-23
33
2144
536
19-25
38
1519
380
11-19
20
2025
506
14-22
25
2531
633
17-25
30
75
19
4-8
-
450
113
5-10
-
TOTAL CFM
CFM/SIDE
THROW
NC
800
200
7-14
-
1200
300
10-17
-
1513
378
9-18
-
2269
567
13-22
21
TOTAL CFM
CFM/SIDE
THROW
NC
1013
253
7-15
-
300
75
6-10
-
675
169
8-14
-
100
25
7-11
-
400
100
9-14
-
900
225
11-17
22
1600
400
13-20
24
3025
756
16-25
26
125
31
9-13
-
500
125
11-16
24
.050
.072
700
113
28
3-5
-
50
13
2-4
-
.035
.050
600
.022
.032
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
500
.013
.018
200
50
3-7
-
TOTAL CFM
CFM/SIDE
THROW
NC
400
.006
.008
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
NECK VELOCITY
150
38
11-16
20
175
44
13-17
25
600
150
13-18
29
700
175
15-20
34
1125
281
14-20
27
1350
338
16-22
32
2000
500
16-23
29
2400
600
18-25
34
3781
945
19-27
31
.068
.099
3037
759
20-27
35
4537
1134
22-30
36
Air Pattern
Diagram
394
98
14-18
31
1575
394
18-23
37
2800
700
21-27
39
3544
886
22-28
40
5294
1323
24-31
41
DCD-36
3/2006
3/2006
6" X 9"
Ak = .217
6" X 12"
Ak = .289
9" X 12"
Ak = .434
9" X 15"
Ak = .542
9" X 18"
Ak = .650
9" X 21"
Ak = .759
12" X 15"
Ak = .723
12" X 18"
Ak = .867
12" X 21"
Ak = 1.012
12" X 24"
Ak = 1.156
15" X 18"
Ak = 1.084
15" X 24"
Ak = 1.445
18" X 24"
Ak = 1.734
21" X 33"
Ak = 2.782
24" X 30"
Ak = 2.890
Ps
Pt
Side Designation
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
A
13
2-4
13
2-4
28
3-5
28
3-5
28
3-5
28
3-5
50
3-7
50
3-7
50
3-7
50
3-7
78
4-8
78
4-8
113
5-10
153
6-12
.006
.008
25
2-5
19
4-8
38
3-6
19
4-8
47
3-7
42
5-9
66
4-8
42
5-9
84
4-9
42
5-9
103
5-10
42
5-9
75
-
100
-
150
-
188
-
225
-
263
-
250
75
4-8
75
6-10
100
5-10
75
6-10
300
-
350
-
125
5-11
400
-
150
6-12
375
-
109
5-10
500
-
172
6-13
600
-
188
6-13
963
-
NECK VELOCITY
300
328
8-17
1000
200
300
7-14
8-16
-
75
6-10
75
6-10
117
7-12
117
7-12
160
8-14
.013
.018
400
38
5-9
25
7-11
56
6-10
25
7-11
113
-
150
-
225
-
70
6-10
281
-
98
7-11
338
-
127
7-12
394
-
155
8-13
375
-
113
7-12
450
-
150
8-13
525
56
8-12
56
8-12
100
9-14
100
9-14
225
9-15
100
9-14
164
8-14
750
258
9-16
900
-
56
8-12
100
9-14
563
-
56
8-12
188
8-14
600
281
10-17
1444
230
492
9-16 12-21
20
1500
300
450
10-17 12-20
20
.022
.032
156
10-15
50
8-12
31
9-13
150
-
500
200
-
75
8-13
300
-
94
9-13
375
-
131
9-14
450
-
169
10-16
525
.035
.050
31
9-13
70
10-15
70
10-15
70
10-15
206
11-17
20
70
10-15
150
10-15
20
125
11-16
200
11-16
20
125
11-16
250
11-18
21
125
11-16
500
600
700
800
300
12-19
22
750
219
11-17
21
63
10-14
38
11-16
250
94
11-15
20
38
11-16
117
11-16
22
84
12-17
164
12-17
23
84
12-17
211
13-18
24
84
12-17
258
13-19
25
84
12-17
188
12-18
25
150
13-18
250
13-19
25
150
13-18
375
469
563
656
625
750
875
313
14-20
26
1000
125
375
11-16 15-21
27
195
12-18
.050
.072
185
-
600
938
273
14-19
26
225
700
43
13-17
113
13-17
25
44
13-17
141
13-18
27
98
14-18
197
14-19
28
98
14-18
253
15-20
29
98
14-18
309
16-21
30
98
14-18
225
14-20
30
175
15-20
300
450
563
675
788
750
900
300
15-21
30
1050
150
375
13-18 16-22
31
1200
150
450
13-18 17-23
32
1125
234
328
15-20 16-22
31
1250
195
430
12-18 15-22
27
1500
234
516
15-20 18-24
32
1925
306
656
12-19 15-24
25
2406
383
820
15-21 18-26
30
2888
459
984
17-23 21-29
35
2000
400
600
13-20 15-23
25
1500
281
469
14-20 16-23
28
2500
500
750
16-23 18-26
30
.068
.099
75
12-17
23
1000
156
344
10-15 13-19
22
1200
225
375
11-17 13-20
23
1800
338
563
16-22 18-25
33
3000
600
900
18-25 21-28
35
263
Air Pattern
Diagram
B
86
14-18
28
350
131
15-19
30
525
164
15-20
32
656
230
16-21
33
788
DCD
NECK SIZE
Ak
200
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
295
17-22
34
919
361
18-23
35
875
263
16-21
35
1050
175
350
15-20 17-23
35
1225
175
438
15-20 18-24
36
1400
175
525
15-20 19-25
37
1313
273
383
17-22 18-23
36
1750
273
602
17-22 20-26
37
2100
394
656
18-23 20-26
38
3369
536
1148
19-25 23-30
40
3500
700
1050
21-27 23-30
40
DCD-37
DCD
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
NECK SIZE
Ak
6" X 6"
Ak = .135
9" X 9"
Ak = .304
12" X 12"
Ak = .541
15" X 15"
Ak = .845
18" X 18"
Ak = 1.216
21" X 21"
Ak = 1.655
24" X 24"
Ak =2.162
27" X 27"
Ak = 2.736
Ps
Pt
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
200
500
169
42
5-9
-
225
56
8-12
-
281
70
10-15
21
335
84
12-17
26
313
78
4-8
-
469
117
7-12
-
625
156
10-15
21
781
195
12-18
26
938
234
15-20
31
1094
273
17-22
36
613
153
6-12
-
919
230
9-16
-
1225
306
12-19
23
1531
383
15-21
28
1837
459
17-23
33
2144
536
19-25
38
1519
380
11-19
20
2025
506
14-22
25
2531
633
17-25
30
450
113
5-10
-
TOTAL CFM
CFM/SIDE
THROW
NC
800
200
7-14
-
1013
253
7-15
-
75
19
4-8
-
300
75
6-10
-
675
169
8-14
-
1200
300
10-17
-
100
25
7-11
-
400
100
9-14
-
900
225
11-17
22
1600
400
13-20
24
125
31
9-13
-
500
125
11-16
24
.050
.072
700
113
28
3-5
-
50
13
2-4
-
.035
.050
600
.022
.032
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
400
.013
.018
200
50
3-7
-
TOTAL CFM
CFM/SIDE
THROW
NC
NECK VELOCITY
.006
.008
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
300
.068
.099
150
38
11-16
20
175
44
13-17
25
600
150
13-18
29
700
175
15-20
34
1125
281
14-20
27
1350
338
16-22
32
2000
500
16-23
29
2400
600
18-25
34
3037
759
20-27
35
Air Pattern
Diagram
394
98
14-18
31
1575
394
18-23
37
2800
700
21-27
39
3544
886
22-28
40
DCD-38
3/2006
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
NECK SIZE
Ak
6" X 9"
Ak = .217
6" X 12"
Ak = .289
9" X 12"
Ak = .434
9" X 15"
Ak = .542
9" X 18"
Ak = .650
9" X 21"
Ak = .759
12" X 15"
Ak = .723
12" X 18"
Ak = .867
12" X 21"
Ak = 1.012
12" X 24"
Ak = 1.156
15" X 18"
Ak = 1.084
15" X 24"
Ak = 1.445
18" X 24"
Ak = 1.734
Ps
Pt
Side Designation
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
200
A
25
2-5
44
3-6
61
4-7
80
4-8
98
5-9
117
5-10
100
5-10
125
5-11
148
6-12
180
6-13
206
7-14
244
7-15
317
8-17
.006
.008
75
-
100
20
150
20
188
20
225
20
263
20
250
20
300
20
375
20
438
20
38
5-9
13
2-4
66
6-10
28
3-5
28
3-5
28
3-5
28
3-5
50
3-6
50
3-7
78
4-8
78
4-8
113
5-10
600
20
113
5-10
788
20
13
2-4
525
20
NECK VELOCITY
300
153
6-12
.013
.018
91
6-11
120
7-12
148
8-13
176
8-14
150
8-13
188
8-14
223
9-15
270
10-17
309
10-17
366
11-19
113
-
150
20
225
20
281
20
338
20
400
B
19
4-8
19
4-8
42
5-9
42
5-9
42
5-9
394
42
5-19
20
375
20
75
6-10
450
75
6-10
20
563
20
117
7-12
656
20
117
7-12
788
20
169
8-14
900
20
169
8-14
1181
476
230
12-20 9-16
20
A
A
.022B
.032
50
8-12
88
8-13
122
9-14
159
10-15
197
11-16
234
11-17
200
11-16
250
11-18
297
12-19
150
-
500
25
B7-11
200
20
25
7-11
300
20
56
8-12
375
20
56
8-12
450
20
56
8-12
525
20
56
8-12
500
20
100
9-14
600
20
100
9-14
750
156
10-15
21
63
10-14
109
11-16
152
12-17
199
12-18
246
13-19
293
14-20
250
13-19
313
14-20
371
15-21
31
9-13
75
12-17
188
-
250
20
.050
.072
31
9-13
375
131
13-18
70
10-15
22
183
14-19
70
10-15
23
239
15-20
70
10-15
24
295
15-21
70
10-15
25
352
16-22
125
11-16
25
300
15-21
125
11-16
25
375
16-22
469
563
656
625
750
938
195
12-18
26
225
700
88
14-18
38
12-17
25
153
15-20
84
12-17
27
213
16-21
84
12-17
28
279
17-22
84
12-17
29
345
17-23
84
13-18
30
410
18-24
150
13-18
30
350
17-23
300
450
563
675
788
750
900
1500
609
281
17-24 14-20
28
1800
731
338
19-26 17-23
33
1969
793
383
18-26 15-21
29
44
13-17
28
350
44
13-17
30
525
1575
619
338
19-25 16-22
33
2362
952
459
21-28
34
98
14-18
32
656
98
14-18
33
788
98
14-18
34
919
98
14-18
35
875
175
15-20
35
1531
629
273
20-26 17-22
37
1125
445
234
17-23 15-20
31
1200
488
225
14-22 11-17
23
1575
634
306
15-24 12-19
24
1050
438
175
18-24 15-20
35
1313
539
234
18-27 16-22
32
1313
516
281
16-23 14-20
28
263
Air Pattern
Diagram
150
15-20
30
1094
449
195
16-22 12-18
27
1050
413
225
13-21 11-17
23
.068
.099
38
11-16
23
156
10-15
22
359
13-20
875
.035
.050
600
DCD
3/2006
1313
520
273
19-25 17-22
36
1837
722
394
21-27 18-23
38
2100
853
394
22-28 18-23
38
2756
1110
536
23-30 19-25
39
DCD-39
3/2006
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
NECK SIZE
Ak
6" X 9"
Ak = .203
6" X 12"
Ak = .270
DCD
9" X 12"
Ak = .405
9" X 15"
Ak = .507
12" X 15"
Ak = .676
12" X 18"
Ak = .811
15" X 18"
Ak = 1.014
15" X 21"
Ak = 1.182
18" X 24"
Ak = 1.182
21" X 27"
Ak = 2.128
24" X 30"
Ak = 2.703
200
Ps
Pt
Side Designation
TOTAL CFM
CFM/SIDE
THROW
NC
28
3-6
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
50
5-9
A
50
5-9
78
4-8
78
4-8
113
5-10
113
5-10
153
6-12
200
7-14
253
7-15
.006
.008
75
-
23
3-6
42
7-12
100
-
25
3-6
B
150
-
188
50
5-9
.013
.018
75
8-15
75
8-15
20
250
20
300
20
55
3-7
117
7-12
86
4-9
117
7-12
94
4-9
169
8-14
375
20
131
5-11
438
20
142
5-11
600
200
7-14
20
788
20
NECK VELOCITY
300
267
7-15
1000
313
344
8-17
8-17
20
169
8-14
230
9-16
300
10-17
113
-
400
35
7-11
150
-
38
7-12
225
-
28
20
75
8-15
82
6-11
375
20
129
7-12
450
20
141
7-13
563
20
197
8-15
656
20
213
9-15
900
300
10-17
20
1181
380
401
11-19 11-19
20
1500
469
516
12-20 12-11
20
.022
.032
56
11-18
100
13-20
100
13-20
156
10-15
156
10-15
225
11-17
225
11-17
306
12-19
47
11-17
70
16-23
200
-
.035
.050
150
-
500
50
11-17
300
125
18-26
100
13-20
20
125
18-26
109
9-14
195
12-18
375
20
500
172
10-16
20
195
12-18
188
10-16
20
281
14-20
263
12-18
21
281
14-20
600
750
875
284
12-18
22
1200
400
400
13-20 13-20
23
1575
506
534
14-22 15-22
24
2000
625
688
15-23 16-24
25
188
600
.050
.072
59
16-23
21
84
21-29
63
16-23
23
150
22-31
125
18-26
25
150
22-31
137
11-16
23
234
15-20
215
13-18
25
234
15-20
234
13-19
25
338
16-22
250
375
469
625
750
938
238
14-20
26
1094
383
355
15-21 15-21
27
1500
500
500
16-23 16-23
28
1969
633
668
17-25 17-25
29
2500
781
859
18-26 19-27
30
225
700
.068
.099
70
20-28
26
98
24-32
75
20-28
A
28
175
26-37
150
22-31
30
175B
26-37
164
14-19
28
273
17-22
258
15-20
30
273
17-22
300
450
563
750
900
281
15-21
30
1125
338
394
16-22 17-23
31
1313
459
427
17-23 17-23
32
1800
600
600
18-25 18-25
33
2362
759
802
20-27 20-27
34
3000
938
1031
21-28 21-29
35
263
Air Pattern
Diagram
B
82
24-34
31
350
88
24-34
33
525
175
26-37
35
656
191
15-20
33
875
301
17-22
35
1050
394
328
18-23 17-22
35
1313
394
459
18-23 19-24
36
1531
536
498
19-25 19-25
37
2100
700
700
21-27 21-27
38
2756
886
935
22-28 22-29
39
3500
1094 1203
23-30 23-31
40
DCD-40
3/2006
Ps
Pt
.006
.008
.013
.018
TOTAL CFM
CFM/SIDE
THROW
NC
113
56
3-7
20
169
84
6-11
20
TOTAL CFM
CFM/SIDE
THROW
NC
6" X 6"
Ak = .132
9" X 9"
Ak = .298
12" X 12"
Ak = .529
18" X 18"
Ak = 1.190
21" X 21"
Ak = 1.620
24" X 24"
Ak = 2.116
27" X 27"
Ak = 2.679
50
25
2-5
20
400
75
38
5-9
20
300
150
8-13
20
TOTAL CFM
CFM/SIDE
THROW
NC
450
225
7-14
20
675
338
10-18
20
800
400
9-18
20
1200
600
13-22
20
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
613
306
8-17
20
1013
506
10-20
20
.035
.050
600
700
.050
.072
.068
.099
100
50
8-12
20
125
63
10-14
20
150
75
12-17
20
175
88
14-18
25
400
200
11-16
20
500
250
13-19
24
600
300
15-21
29
700
350
17-23
34
225
113
9-14
20
200
100
5-10
20
313
156
6-12
20
500
.022
.032
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
15" X 15"
Ak = .827
NECK VELOCITY
300
281
141
12-17
21
781
391
15-21
26
469
234
9-16
20
625
313
12-19
21
919
459
12-20
20
1225
613
15-23
23
1531
766
18-26
28
1519
759
14-24
20
2025
1013
17-27
25
2531
1266
21-29
30
900
450
14-21
22
1600
800
16-25
24
338
169
14-19
26
394
197
16-20
31
938
469
17-24
31
1094
547
19-25
36
1837
919
21-28
33
2144
1072
23-30
38
1125
563
17-24
27
1350
675
19-26
32
2000
1000
19-28
29
2400
1200
22-30
34
3037
1519
23-32
35
DCD
NECK SIZE
Ak
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
1575
788
21-28
37
2800
1400
24-30
39
3544
1772
25-33
40
200
Ps
Pt
.008
.010
TOTAL CFM
THROW
NC
113
5-10
20
TOTAL CFM
THROW
NC
313
8-17
20
TOTAL CFM
THROW
NC
615
10-21
20
TOTAL CFM
THROW
NC
1013
12-24
20
TOTAL CFM
THROW
NC
TOTAL CFM
THROW
NC
TOTAL CFM
THROW
NC
TOTAL CFM
THROW
NC
50
3-7
20
300
.018
.023
75
6-10
20
169
8-14
20
NECK VELOCITY
400
.031
.041
100
9-14
20
675
13-23
20
900
17-26
22
500
16-23
24
600
18-25
29
700
21-27
34
1094
23-30
36
1837
24-33
33
2144
26-35
38
2000
23-32
29
2400
25-34
34
1531
21-31
28
1519
16-28
20
2025
20-31
25
2531
23-34
30
3037
26-36
35
Air Pattern
Diagram
394
18-23
31
938
21-28
31
1350
23-31
32
1225
18-28
23
1600
19-30
24
338
16-22
26
1125
20-29
27
919
14-25
20
1200
15-27
20
.095
.126
175
15-20
25
781
18-26
26
450
9-19
20
.070
.092
700
150
13-18
20
625
15-23
21
400
13-20
20
600
125
11-16
20
281
14-20
21
300
10-17
20
800
11-23
20
.049
.064
225
11-17
20
200
7-14
20
469
12-20
20
500
1575
25-32
37
2800
28-36
39
3544
29-38
40
DCD-41
DCD
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
NECK SIZE
Ak
6" x 9"
Ak = .198
6" x 12"
Ak = .265
6" x 15"
Ak = .333
6" x 18"
Ak = .397
9" x 15"
Ak = .496
9" x 18"
Ak = .595
9" x 21"
Ak = .694
12" x 15"
Ak = .661
12" x 18"
Ak = .794
12" x 21"
Ak = .926
15" x 21"
Ak = 1.157
15" x 24"
Ak = 1.323
18" x 21"
Ak = 1.386
18" x 24"
Ak = 1.587
21" x 27"
Ak = 2.083
200
Ps
Pt
.007
.009
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
.015
.021
NECK VELOCITY
400
.027
.037
500
.042
.057
600
.060
.082
700
.082
.112
100
50
3-7
20
113
56
6-10
20
150
75
6-10
20
150
75
8-13
20
188
94
11-15
20
225
113
13-17
23
263
131
15-19
28
150
75
4-8
20
225
113
7-12
20
250
125
9-14
20
300
150
10-15
20
313
156
12-17
21
375
188
14-19
26
438
219
16-21
31
TOTAL CFM
CFM/SIDE
THROW
NC
225
113
5-10
20
338
169
8-14
20
375
188
10-16
20
450
225
11-17
20
469
234
13-19
23
TOTAL CFM
CFM/SIDE
THROW
NC
250
125
5-11
20
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
75
38
3-6
20
300
125
63
4-7
20
188
94
4-9
20
263
131
5-11
20
188
94
6-11
20
281
141
7-13
20
394
197
8-15
20
375
188
8-14
20
525
263
12-18
20
500
250
11-18
20
525
263
9-16
20
700
350
13-20
21
TOTAL CFM
CFM/SIDE
THROW
NC
300
150
6-12
20
TOTAL CFM
CFM/SIDE
THROW
NC
438
219
7-14
20
656
328
10-18
20
525
263
7-15
20
788
394
11-19
20
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
350
175
6-13
20
500
250
7-15
20
600
300
8-16
20
788
394
9-18
20
200
100
9-14
20
450
225
9-15
20
600
300
12-19
20
375
188
12-18
22
563
281
14-20
24
656
328
14-20
25
1575
788
16-25
24
675
338
16-22
29
1050
525
18-24
31
1250
625
17-25
27
1500
750
20-27
32
1313
656
17-25
28
1200
600
15-23
23
563
281
15-21
28
875
438
15-22
26
750
375
15-21
25
1050
525
14-22
23
900
450
12-20
20
450
225
14-20
27
625
313
14-20
25
1094
547
16-24
27
1000
500
14-22
22
300
150
13-18
25
788
394
17-23
30
750
375
16-22
30
875
438
14-21
22
750
375
11-19
20
1181
591
13-22
20
250
125
11-16
20
1500
750
18-26
28
1969
984
19-28
29
350
175
15-20
30
525
263
16-21
32
656
328
17-22
33
788
394
18-23
34
919
459
19-24
35
875
438
18-24
35
900
450
17-23
30
1050
525
19-25
35
1313
656
19-26
32
1531
766
21-27
37
1575
788
20-27
33
1800
900
21-28
33
2362
1181
22-30
34
1225
613
20-26
36
1750
875
22-28
37
1837
919
22-29
38
2100
1050
23-30
38
2756
1378
24-32
39
DCD-42
3/2006
3/2006
Ps
Pt
CFM
6" x 9" TOTAL
THROW
Ak = .183
NC
200
.008
.010
CFM
12" x 18" TOTAL
THROW
Ak = .733
NC
.095
.126
263
16-21
28
125
5-11
20
188
8-14
20
250
11-18
20
313
14-20
21
375
16-22
26
438
18-24
31
150
8-13
20
200
11-16
20
225
9-15
20
300
12-19
20
188
6-13
20
281
10-17
20
375
13-20
20
250
7-15
20
375
11-19
20
175
6-13
20
225
7-14
20
263
9-16
20
338
10-18
20
350
13-20
20
450
14-21
20
500
14-22
20
300
8-16
20
450
12-20
20
500
15" x 24" TOTAL CFM 10-20
Ak = 1.222 THROW
NC
20
750
14-24
20
1000
17-27
22
900
14-25
20
1200
18-28
23
.070
.092
700
225
14-20
23
CFM
9" x 15" TOTAL
THROW
Ak = .458
NC
TOTAL CFM
THROW
NC
.049
.064
600
188
12-18
20
150
6-12
20
12" x 15"
Ak = .611
.031
.041
500
150
10-15
20
CFM
6" x 18" TOTAL
THROW
Ak = .366
NC
CFM
9" x 18" TOTAL
THROW
Ak = .550
NC
400
113
7-12
20
100
5-10
20
CFM
6" x 21" TOTAL
THROW
Ak = .429
NC
.018
.023
NECK VELOCITY
75
4-8
20
CFM
6" x 12" TOTAL
THROW
Ak = .244
NC
CFM
6" x 15" TOTAL
THROW
Ak = .307
NC
300
438
9-19
20
525
18" x 21" TOTAL CFM 10-20
Ak = 1.278 THROW
NC
20
600
18" x 24" TOTAL CFM 10-21
Ak = 1.467 THROW
NC
20
788
21" x 27" TOTAL CFM 11-23
Ak = 1.925 THROW
NC
20
656
13-23
20
788
14-24
20
1181
15-26
20
600
15-23
20
250
13-19
20
300
12-19
20
438
15-22
23
469
16-23
23
563
17-24
24
625
17-25
25
750
18-26
25
300
15-21
25
450
17-23
27
525
18-24
28
563
18-25
28
675
19-26
29
750
20-27
30
900
21-28
30
875
17-26
22
1094
20-28
27
1313
22-31
32
1050
18-27
23
1313
21-30
28
1575
23-32
33
1575
19-30
24
1250
20-29
27
1500
21-31
28
1969
23-32
29
1500
23-31
32
1800
24-33
33
2362
25-34
34
350
17-23
30
525
19-25
32
613
20-26
33
656
20-26
33
DCD
NECK SIZE
Ak
Models 5000 (-1, -2, -4, -46, -6, -7, -8, -9)
788
21-28
34
875
22-28
35
1050
23-30
35
1531
25-32
37
1750
25-33
37
1837
26-34
38
2100
26-34
38
2756
28-36
39
DCD-43
3/2006
Surface Mount
Drop Face
Drop Face T-Bar Lay-in
T-bar Lay-in
Concealed Spline
Tegular Lay-in
Donn Fineline
Air Outlets shall be aluminum model 5000 manufactured by METALAIRE. Units shall consist of a fixed pattern louvered core fastened into a border with
spring loaded latches. Core shall be removable without the use of tools. Outlets shall be engineered for high capacity applications and include straight
deflector blades (without a horizontal lip). Units with a horizontal lip at the ends of the deflector blades are not acceptable. The units shall be the size
and quantity as outlined in the plans and specifications.
Outlets shall be available in 1, 2 way opposite, 2 way corner, 3, and 4 way directional air patterns.
Units shall be designed to integrate into the specified ceiling system.
DCD
Options
Adjustable Pattern (horizontal to vertical)
Outlets shall include adjustable air pattern deflector blades that allows the air pattern to be set from vertical to horizontal (Optional APD Air Pattern
Deflectors). Air pattern deflector blades shall be accessible from the face and the diffuser and adjustable without the use of tools.
IV Induction Vanes
Units shall include IV induction vanes factory mounted onto the back side of the deflector vanes. IV vanes shall increase the induction rate of the diffuser.
Accessories
Optional Dampers
Aluminum D5A or Steel D5 opposed blade dampers shall be provided. Damper shall be adjusted using a handle accessible through the face of the diffuser.
Screwdriver slot operators are not allowed.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Film thickness
Film Cure
Gloss 60 deg.
Pencil Hardness
Crosshatch Adhesion
Direct Impact
Reverse Impact
Salt Spray
Humidity
Water Soak
DCD-44
Test Method
ASTM D523-89
ASTM D3363-92A
ASTM D3359-95
ASTM D2794-93
ASTM D2794-93
ASTM B117-95
ASTM D1735-92
ASTM D870-92
Performance
.8-1.0 mils
320 F @ 20 min
70-80%
HB-H
4B-5B
60 in.lbs. Min
60 in.lbs. Min.
48-96 Hours
500 Hours
250 Hours
3/2006
Model
Available Neck
Available Finishes
Standard
Standard
Available Options
D5
D5A
L9
Equalizing Grid
6"
thru
48"
S4
- Sq. 4-way
01 - White
Optional
Optional
S1
- Sq. 1-way
02 - Aluminum
TR
S2
- Sq. 2-way
03 - Black
TR DEEP
S3
- Sq. 3-way
24 - Mill
G3
Equalizing Grid
28 - Custom Color
BDS
Butterfly Damper
RSD
IV
Induction Vanes
APD
DCD
Air Pattern
Available Neck
Module
12" x 12"
6"
24" x 24"
thru
36" x 24"
42"
48" x 24"
48" x 48"
S4
Air Pattern
Available Finishes
Standard
Standard
- Sq. 4-way
01 - White
Available Options
D5
D5A
Optional
Optional
L9
Equalizing Grid
S1
- Sq. 1-way
02 - Aluminum
TR
S2
- Sq. 2-way
03 - Black
TR DEEP
S3
- Sq. 3-way
24 - Mill
G3
Equalizing Grid
28 - Custom Color
BDS
Butterfly Damper
RSD
IV
Induction Vanes
APD
DCD-45
3/2006
1
12
*
Square/Rectangular
Louver Face Series 5500 Aluminum
Product Details
3
1
14
1 21 opposite, 2-way corner,
16
Available
in 1, 2-way
Diffuser air
= Listed
Size + 5 43
3, and 4-wayOverall
directional
patterns
Size + 3 3
4
ze - 1
8
23
8
1
18
13 *
16
1
Overall Diffuser = Listed size + 5
8
1
14
DCD
Size + 5 43
Ceiling Opening
= Listed Size + 1
Ceiling
Opening
= Listed
Size + 3
Square/Rectangular Louver
Face
Ceiling
Diffusers
Overall Diffuser = Listed size + 15 74
8
Neck Size = Listed Size Surface Mount
8
1
Ceiling Opening =
Model 5500-1 1 2 *
57
8
13 *
16
Ceiling
Line
1
22
1
12
1
1Neck
4
1
18
Ceiling
Line
3 1
41 4
3
16
1
Listed Size + 2
3
16
1
22
1
22
1
8
1
ule - 4
and 48 x 48
13 *
16
3
4
DCD-46
1
Overall Panel = T-Bar Module - 4
T-Bar Module =
12 x 12, 24 x 24, 36 x 24, 48 x 24 and 48 x 48
T-bar
1
12
13 *
16
3
Overall
Diffuser
= Listed
size + 5 1
Optional APD
adjustable
8
4
1
22
1
14
Overall Diffu
Neck Size =
1
Overall Diffuser = Modual - 4
1
12
1
Neck Size = Listed Size - 8
T-bar 1
22
1
12
Ceiling
Line
3
4
1
22
3
4
Overall Diffuse
23
8
1
14
1
22
3
4
1
18
13 *
16
23
8
16
Ceiling Opening
=Diffuser
Listed
+ 1- +1 5 1
Overall
Diffuser
= Listed
size
Overall
=Size
Modual
Ceiling
Line
Duct Siz
13 *
1
14
11
8
Optional
APD adjustable
1 21
Pattern Deflector Vane
Ceilin
= List
Square/Rectangular LouverDuct
FaceSize
Ceiling
Diffusers
= Listed
Size
V-Beveled Drop Surface Mounting
Model 5500-2
23
1
Overall
Diffuser
Modual - 4
Square/Rectangular Louver
Face
Ceiling=Diffusers
Concealed Spline
1
Model 5500-7
Neck Size = Listed Size - 8
T-bar
1
12
Ceiling
Line
1
22
Concealed T-Bar
1
22
(2) Kerfs
Option
Patte
1
Neck Size = Listed Size - 8
(At Least 6" Less Than
T-Bar Spacing)
11 *
1 16
1
Neck Size = Listed Size - 8
Concealed T-Bar
Neck Size =
(At Least 6
T-Bar S
e
1
3
8
1
4
22 7 x 22 7 Overall Face
8
8
1
Overall Diffuser = T-Bar Module - 4
11 *
1 16
Optional D5
Opposed Blade Damper
11 *
1 16
Lay-In Filler Panel
3
8
3
23 3
8 x 23 8
3
Overall Diffuser = 23 3
4 x 23 4
T-Bar Module = 24 x 24
3/2006
Duct Open
1 (Max
-8
23 3
8
Overall Diffuse
S1 - One Way
S3 - Three Way
DCD
Long
R4 - Four Way
Duct Size - 85
Optional D5
Opposed Blade Damper
Duct Size - 85
Optional D5
Opposed Blade Damper
23
8
3
3
16
1
12
IV Induction Vane
-Available for all 5000
5500 series borders and sizes.
-Cannot be used with APD option.
-IV Induction Vanes are factory mounted.
1. Available Finishes
2. Available Accessories
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
Note:
Anodized Finish not available
3. Available Options
Factory Mounted:
IV - Induction Vanes
APD - Air Pattern Deflectors allows
adjustment from horizontal to vertical air
pattern from the face of the diffuser
4. Construction Details
Available air patterns:
S1, S2, S3, S4, R1S, R1L, R2S, R2L, R3S,
R3L, R4 and SC (Type)
For 5500-6 models only:
21" x 21" neck in 24" x 24" module is
available in S4 pattern only
Overall
Diffuser
DCD-47
3/2006
DCD
Product 1Details 1
3
16 1 4Available 1in2 1,
3
Neck Size = Listed Size - 16
5500S is also available with
The
optional induction vanes
3
1
1
1 are
Dimensions
16
4 in inches 1 2
9
Face Size A = Listed Size + 5 16
Square/Rectangular Louver Face Ceiling Diffusers
3
Neck Size
= Listed Size
Model
5500S-6
S4- Shown
16
11
8
Square/Rectangular Louver Face Ceiling Diffusers
V-Beveled Drop Surface Mounting - Steel
Model 5500S-2
3
16
1
14
2
11
1
Neck Size = Listed Size - 8
(Maximum 15 x 15)
3
16
1
1
14
12
Face Size A = T-Bar Spacing - 41
1
12
3
Neck Size = Listed Size - 16
1
Neck Size = Listed Size - 8
(Maximum 15 x 15)
3
Overall Diffuser = 23 3
4 x 23 4
3
8
12
14
23 3
x 23 3
8
8
22 7 x 22 7 Overall Face
8
8
1
Overall Diffuser = T-Bar Spacing - 4
T-Bar Module = 24 x 24
1
12
22 7 x 22 7 Overall Face
8
8
1
Overall Diffuser = T-Bar Spacing - 4
T-Bar Module = 24 x 24
DCD-48
For more product information visit us at www.metalaire.com
3/2006
S3 - Three Way
S4 - Four Way
Long
R4 - Four Way
S1 - One Way
Duct Size - 85
Optional D5
Opposed Blade Damper
DCD
IV (Face View)
Overall Diffuser
1
Neck Size = Listed Size - 8
Duct Size - 85
Optional D5
Opposed Blade Damper
23
8
3
3
16
1
12
IV Induction Vane
-Available for all 5500S
5000 series borders and sizes.
-Cannot be used with APD option.
-IV Induction Vanes are factory mounted.
1. Available Finishes
2. Available Accessories
3. Available Options
4. Construction Details
Overall
Diffuser
See Page DCD-52
for Performance
Notes
1
Neck Size = Listed Size - 8
23
8
3
16
3
16
IV (Face View)
Induction Vane
OverallIVDiffuser
1all 5000 series borders and sizes.
Neck Size =-Available
Listed Sizefor
-8
-Cannot be used with APD option.
-IV Induction Vanes are factory mounted.
23
8
Overall
Diffuser
Overall
Diffuser
IV Induction Vane
-Available for all 5000 series borders and sizes.
-Cannot be used with APD option.
-IV Induction Vanes are factory mounted.
DCD-49
DCD
15 x 15
Ak = .546
18 x 18
Ak = .787
21 x 21
Ak = 1.071
24 x 24
Ak = 1.399
27 x 27
Ak = 1.770
Ps
Pt
TOTAL CFM
THROW
NC
TOTAL CFM
THROW
NC
200
.018
.020
50
5-9
-
300
.040
.046
175
26-37
28
300
16-27
-
400
21-33
22
500
26-38
27
600
31-44
32
700
35-50
37
469
17-30
-
TOTAL CFM
THROW
NC
613
16-28
-
TOTAL CFM
THROW
NC
TOTAL CFM
THROW
NC
800
19-29
-
1013
21-31
-
700
.218
.248
150
22-31
23
313
12-24
450
14-26
-
600
.160
.182
125
18-26
-
TOTAL CFM
THROW
NC
TOTAL CFM
THROW
NC
500
.111
.127
100
13-20
-
169
12-21
-
200
11-22
-
400
.071
.081
75
8-15
-
113
8-16
-
TOTAL CFM
THROW
NC
NECK VELOCITY
675
22-32
20
919
26-34
21
1200
28-36
22
1519
30-39
23
225
17-27
-
625
23-35
24
281
22-32
24
781
28-41
29
900
33-45
25
1125
36-48
30
1600
39-45
27
2000
40-53
32
1225
33-43
26
2025
35-49
28
1531
37-51
31
2531
41-55
33
338
27-38
29
394
31-44
34
938
33-47
34
1094
37-52
39
1837
40-55
36
2144
42-58
41
1350
38-52
35
2400
41-59
37
3037
43-60
38
1575
40-56
40
2800
44-61
42
3544
46-64
43
Models 5500 (-1, -2, -4, -46, -6, -7, -8, -9)
Models 5500S (-1, -2, -4, -46, -6, -7, -8, -9)
(SC) 2-Way Adjacent or or (S2) Opposite Pattern
NECK SIZE
Ak
6x6
Ak = .087
9x9
Ak = .197
12 x 12
Ak = .350
15 x 15
Ak = .546
18 x 18
Ak = .787
21 x 21
Ak = 1.071
24 x 24
Ak = 1.399
27 x 27
Ak = 1.770
Ps
Pt
TOTAL CFM
CFM/SIDE
THROW
NC
200
.018
.020
50
25
3-6
-
TOTAL CFM
CFM/SIDE
THROW
NC
113
56
5-10
-
TOTAL CFM
CFM/SIDE
THROW
NC
313
156
10-19
-
TOTAL CFM
CFM/SIDE
THROW
NC
613
306
12-24
-
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
300
.040
.046
75
38
7-12
-
175
88
24-34
28
400
200
16-26
22
500
250
21-31
27
600
300
26-37
32
700
350
30-42
37
900
450
22-34
25
919
459
17-30
21
1225
613
23-35
26
1519
759
12-21
23
2025
1013
17-27
28
1200
600
16-28
22
700
.218
.248
150
75
20-28
23
625
313
19-30
24
675
338
16-28
20
600
.160
.182
125
63
16-23
-
469
234
14-25
-
450
225
12-23
-
500
.111
.127
100
50
11-17
-
225
113
13-21
-
300
150
12-20
-
1013
506
8-15
-
400
.071
.081
169
84
9-15
-
200
100
7-14
-
800
400
12-22
-
NECK VELOCITY
1600
800
21-34
27
281
141
18-27
24
781
391
25-36
29
338
169
23-32
29
938
469
30-41
34
1094
547
33-47
39
1837
919
33-47
36
2144
1072
37-52
41
3037
1519
27-38
38
3544
1772
31-43
43
1125
563
27-39
30
1350
675
32-45
35
2000
1000
27-39
32
2400
1200
32-45
37
1531
766
28-41
31
2531
1266
22-32
33
394
197
27-38
34
1575
788
36-51
40
2800
1400
36-50
42
DCD-50
3/2006
3/2006
NECK SIZE
Ak
6x6
Ak = .100
9x9
Ak = .225
12 x 12
Ak = .400
15 x 15
Ak = .625
18 x 18
Ak =.900
21 x 21
Ak = 1.225
24 x 24
Ak = 1.600
27 x 27*
Ak = 2.025
Ps
Pt
Side
Designation
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
200
A
19
3-5
42
4-8
75
6-12
75
6-12
169
10-20
230
12-23
300
12-24
.013
.016
50
0
113
0
200
0
313
0
450
0
13
2-4
28
6-11
28
3-6
63
8-14
50
5-9
113
10-17
50
5-9
176
12-22
113
8-16
613
0
153
10-19
800
0
NECK VELOCITY
300
200
11-22
1013
380
253
12-23 12-24
0
253
15-25
345
16-28
.030
.036
75
0
169
0
300
0
400
19
6-10
38
10-16
42
7-12
84
12-19
75
8-15
469
0
117
10-18
675
20
169
12-21
919
21
230
14-24
1200
450
300
17-30 16-27
22
1519
570
380
17-29 17-19
23
150
15-23
.053
.063
25
10-16
47
15-22
100
0
500
225
0
56
11-18
400
100
13-20
22
625
234
156
17-27 15-23
24
338
20-31
900
25
225
17-27
105
17-25
188
20-29
293
23-33
.083
.099
31
15-21
56
20-28
125
0
600
281
24
70
16-23
500
27
125
18-26
781
29
195
20-29
225
24-34
352
27-38
38
19-27
66
24-33
150
23
338
29
84
21-29
600
32
150
22-31
938
34
234
25-35
1125
422
281
25-37 22-32
30
1350
506
338
30-42 27-38
35
2000
750
500
28-41 26-38
32
2400
900
600
33-47 31-44
37
1225
459
306
22-34 19-30
26
1531
574
383
27-40 24-36
31
2025
759
506
22-34 22-35
28
2531
949
633
27-40 28-40
33
1600
600
400
23-35 21-33
27
127
22-31
.120
.142
Air Patterns
(Square) Louver Face Ceiling Diffusers
700
1837
689
459
32-45 29-41
36
3037
1139
759
32-46 33-46
38
148
26-36
263
28-40
.163
.194
175
28
S3 - Three Way
44
23-32
394
34
S1 - One Way
98
24-34
700
37
175
26-37
1094
410
273
31-44 29-40
39
DCD
Models 5500 (-1, -2, -4, -46, -6, -7, -8, -9)
Models 5500S (-1, -2, -4, -46, -6, -7, -8, -9)
(S3) 3 Way Square Pattern
1575
591
394
34-48 31-44
40
2144
804
536
36-51 33-47
41
2800
1050
700
37-52 35-50
42
3544
1329
886
36-51 37-52
43
DCD-51
DCD
12 x 12
Ak = .400
15 x 15
Ak = .625
18 x 18
Ak = .900
21 x 21
Ak = 1.225
24 x 24
Ak = 1.600
27 x 27*
Ak = 2.025
33 x 33*
Ak = 3.025
200
300
400
Ps
Pt
.013
.016
TOTAL CFM
CFM/SIDE
THROW
NC
113
28
3-6
-
169
42
7-12
-
TOTAL CFM
CFM/SIDE
THROW
NC
313
78
6-12
-
469
117
10-18
-
TOTAL CFM
CFM/SIDE
THROW
NC
613
153
10-19
-
919
230
14-24
21
1225
306
19-30
26
TOTAL CFM
CFM/SIDE
THROW
NC
1013
253
12-24
-
1519
380
17-29
23
2025
506
22-35
28
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
TOTAL CFM
CFM/SIDE
THROW
NC
50
13
2-4
-
200
50
5-9
-
450
113
8-16
-
.030
.036
NECK VELOCITY
.053
.063
500
.083
.099
600
.120
.142
700
.163
.194
75
19
6-10
-
100
25
10-16
-
125
31
15-21
-
150
38
19-27
23
175
44
23-32
28
300
75
8-15
-
400
100
13-20
22
500
125
18-26
27
600
150
22-31
32
700
175
26-37
37
675
169
12-21
20
900
225
17-27
25
1225
306
22-32
30
1350
338
27-38
35
1600
400
21-33
27
2000
500
26-38
32
2400
600
31-44
37
800
200
11-22
-
1200
300
16-27
22
1513
378
12-23
-
2269
567
17-29
24
225
56
11-18
-
625
156
15-23
24
3025
756
22-34
29
281
70
16-23
24
781
195
20-29
29
1531
383
24-36
31
2531
633
28-40
33
3781
945
27-40
34
338
84
21-29
29
394
98
24-34
34
938
234
25-35
34
1094
273
29-40
39
1837
459
29-41
36
2144
536
33-47
41
3037
759
33-46
38
4537
1134
33-46
39
Air Pattern
S4 - Four Way
1575
394
31-44
40
2800
700
35-50
42
3544
886
37-52
43
5294
1323
36-51
44
DCD-52
3/2006
3/2006
Optional IV
1
14
1
12
IV Induction Vane
Performance Data
Size
6" x 6"
9" x 9"
12" x
12"
15" x
15"
18" x
18"
21" x
21"
Pv in Inches H20
Ps in Inches H20
200
.003
.015
Total CFM
1-Way
2-Way
3-Way
4-Way
NC
50
2
1
1 1
1
<
Total CFM
1-Way
2-Way
3-Way
4-Way
NC
200
6
4
2 3
2
<
Total CFM
1-Way
2-Way
3-Way
4-Way
NC
450
9
7
4 5
4
<
Total CFM
1-Way
2-Way
3-Way
4-Way
NC
Total CFM
1-Way
2-Way
3-Way
4-Way
NC
Total CFM
1-Way
2-Way
3-Way
4-Way
NC
300
.006
.030
.010
.050
500
.016
.078
600
.022
.110
75
4
3
2 2
2
<
100
7
4
2 3
2
<
125
8
6
3 5
3
<
150
10
7
4 6
4
<
300
10
7
5 6
5
<
400
12
9
7 8
7
<
500
15
12
8 10
8
23
600
17
13
9 11
9
28
110
4
2
1 2
2
<
170
7
5
2 4
3
<
310
8
5
3 4
3
<
470
11
8
7 8
6
<
610
10
7
5 6
5
<
400
675
12
10
8 9
8
<
920
14
11
9 10
9
<
225
10
7
3 5
5
<
280
11
8
6 7
6
<
625
14
11
8 10
8
<
780
17
12
10 12
10
23
1225
18
14
11 12
11
1530
22
17
13 15
13
28
900
16
12
10 11
10
<
1125
20
15
11 14
11
23
335
12
11
7 9
7
23
700
.150
.030
175
11
8
4 8
6
23
390
16
12
9 11
9
28
0.008
0.002
50
2 6
3 7
5 9
7 13
<10
615
4 14
6 17
9 21
17 29
<15
400
0.031
0.010
500
0.049
0.016
600
0.070
0.022
700
0.095
0.031
75
4 8
5 9
6 11
9 15
<15
100
5 9
6 10
7 13
10 18
16
125
6 10
7 12
8 14
12 20
18
150
6 11
7 13
9 15
13 22
25
175
7 12
8 14
10 17
14 24
28
300
6 12
8 14
10 17
14 24
<15
400
8 14
9 16
12 20
16 28
18
500
9 16
11 18
13 22
18 32
22
600
10 17
12 20
14 24
20 35
27
700
11 19
12 22
15 26
22 37
32
1350
14 23
16 27
19 33
27 47
35
1575
15 25
17 29
21 36
29 51
40
470
6 15
8 18
13 22
18 31
17
450
4 14
6 16
9 19
16 27
<15
2140
30
26
18 22
18
38
0.017
0.006
315
4 13
6 14
8 18
14 25
<10
1575
27
22
16 18
16
33
1835
25
20
15 17
15
33
170
5 12
7 13
9 16
13 23
<15
200
3 10
5 12
8 14
12 20
<10
1090
25
17
14 16
14
33
300
115
3 10
4 11
7 14
11 19
<10
700
20
15
11 14
11
33
935
20
15
12 14
12
28
1350
22
17
14 15
14
28
200
675
7 17
9 19
14 23
19 33
19
920
7 18
9 21
14 25
21 36
20
225
7 13
9 15
11 19
15 27
17
625
8 18
11 20
14 25
20 35
23
900
9 19
12 22
16 27
22 38
25
1225
9 21
12 24
17 29
24 42
25
280
9 15
10 17
12 21
17 30
20
780
10 20
13 23
16 28
23 39
29
1125
12 21
14 25
17 30
25 43
30
1530
12 23
15 27
19 33
27 46
31
340
9 16
11 19
13 23
19 33
26
940
13 22
14 25
18 31
25 43
34
1840
14 25
17 29
21 36
29 51
36
800
DCD
Optional IV - Performance
B
0.124
0.040
200
7 13
8 15
10 18
15 25
33
395
10 18
12 20
14 25
20 35
31
450
11 19
13 22
15 27
22 38
35
1095
14 23
16 27
19 33
27 47
39
1250
14 25
17 29
20 35
29 50
45
2145
16 28
18 32
22 39
32 55
41
2450
17 29
20 34
24 42
34 59
47
800
12 20
13 23
16 28
23 40
36
1800
16 27
18 31
22 38
31 54
46
DCD-53
3/2006
Surface Mount
Drop Face
Drop Face T-bar Lay-in
T-bar Lay-in
Concealed Spline
Tegular Lay-in
Donn Fineline Lay-in
Air Outlets shall be aluminum model 5500 manufactured by METALAIRE. Units shall consist of a fixed pattern louvered core fastened into a border with
spring loaded latches. Core shall be removable without the use of tools. Outlets shall be engineered to perform in variable volume systems and include
deflector blades with a horizontal lip to provide longer throw distances. The units shall be the size and quantity as outline in the plans and specifications.
Outlets shall be available in 1, 2-way opposite, 2-way corner, 3, and 4-way directional air patterns.
Units shall be designed to integrate into the specified ceiling system.
DCD
Surface Mount
T-bar Lay-in
Tegular Lay-in
Donn Fineline Lay-in
Air Outlets shall be steel model 5500S manufactured by METALAIRE. Units shall consist of a fixed pattern louvered core fastened into a border with
spring loaded latches. Core shall be removable without the use of tools. Outlets shall be engineered to perform in variable volume systems and include
deflector blades with a horizontal lip to provide longer throw distances. The units shall be the size and quantity as outline in the plans and specifications.
Outlets shall be available in 1, 2-way opposite, 2-way corner, 3, and 4-way directional air patterns.
Units shall be designed to integrate into the specified ceiling system.
Options
Adjustable Pattern (horizontal to vertical)
Outlets shall include adjustable air pattern deflector blades that allows the air pattern to be set from vertical to horizontal (Optional APD Air Pattern
Deflectors). Air pattern deflector blades shall be accessible from the face and the diffuser and adjustable without the use of tools.
IV Induction Vanes
Units shall include IV induction vanes factory mounted onto the back side of the deflector vanes. IV vanes shall increase the induction rate of the diffuser.
Accessories
Optional Dampers
Aluminum D5A or Steel D5 opposed blade dampers shall be provided. Damper shall be adjusted using a handle accessible
through the face of the diffuser. Screwdriver slot operators are not allowed.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
DCD-54
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Available Neck
Air Pattern
Standard
6"
thru
48"
Available Finishes
Standard
S4 - Sq. 4-way
01 - White
Available Options
D5
D5A
Optional
Optional
L9
Equalizing Grid
S1 - Sq. 1-way
02 - Aluminum
TR
S2 - Sq. 2-way
03 - Black
TR Deep
S3 - Sq. 3-way
24 - Mill
G3
Equalizing Grid
28 - Custom Color
BDS
Butterfly Damper
RSD
IV
Induction Vanes
APD
TR
Transition-Mounted
DCD
Model
Available Neck
Module
Available Finishes
Standard
Standard
Available Options
D5
D5A
Optional
L9
Equalizing Grid
S1 - Sq. 1-way
02 - Aluminum
TR
S2 - Sq. 2-way
03 - Black
TR Deep
S3 - Sq. 3-way
24 - Mill
G3
Equalizing Grid
28 - Custom Color
BDS
Butterfly Damper
RSD
IV
Induction Vanes
APD
TR
Transition-Mounted
12" x 12"
6"
24" x 24"
thru
36" x 24"
46"
48" x 24"
Air Pattern
S4 - Sq. 4-way
Optional
01 - White
48" x 48"
DCD-55
Available Neck
Air Pattern
Available Finishes
6"
Standard
Standard
Available Options
D5
D5A
L9
Equalizing Grid
thru
5500S-2 - V-Beveled Drop Surface Mount
S4 - Sq. 4-way
24"
01 - White
Options
DCD
Optional
S1 - Sq. 1-way
02 - Aluminum
TR
S2 - Sq. 2-way
03 - Black
TR Deep
S3 - Sq. 3-way
24 - Mill
G3
Equalizing Grid
28 - Custom Color
BDS
Butterfly Damper
RSD
IV
Induction Vanes
APD
TR
Transition-Mounted
Available Neck
Module
Air Pattern
Available Finishes
Standard
Standard
Available Options
D5
D5A
Optional
L9
Equalizing Grid
S1 - Sq. 1-way
02 - Aluminum
TR
S2 - Sq. 2-way
03 - Black
TR Deep
S3 - Sq. 3-way
24 - Mill
G3
Equalizing Grid
28 - Custom Color
BDS
Butterfly Damper
RSD
IV
Induction Vanes
APD
TR
Transition-Mounted
6"
12" x 12"
thru
21"
24" x 24"
S4 - Sq. 4-way
Options
01 - White
DCD-56
3/2006
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
Product Details
Removable core for concealed mounting
1
Ceiling Opening = Listed Size + 2
Listed Size = Duct Size
1
Listed Size - 4
1
Ceiling Opening = Listed Size + 2
Listed Size = Duct Size
1
Listed Size - 4
DCD
1
3
g = Listed Size + 2
1
1
16 2=8Listed Size +
Ceiling Opening
2
Duct Size
Dimensions are in inches Listed
Size
=
Duct
Size
1
1 23
d Size - 4
Listed Size + 2 111
32
Listed Size 16
Listed Size + 2 11
16
Economical Square Diffusers - Surface4Mount
3
1
Model 5200-1 16 2
8
ize + 2 11
16
1
Listed Size + 2
1 23
32
1
Ceiling Opening = Listed Size + 2
Listed Size = Duct Size
1
Listed Size - 4
e + 2 11
16
Optional
Opposed Blade Damper
3
1
16 2 8
CeilingSize
Opening
Listed Size
Listed
+ 2= 11
16
1 23
32
g = Listed Size
Listed Size + 3 3
16
1
28
ze + 3 3
16
= Listed Size
5
2 32
31
1 32
Optional
Opposed Blade Dam
5
2 32
Optional
Opposed Blade Damper
Optional
13
4
9
16
e = Duct Size
1
Size - 4
31
1 32
3
Listed
9 Size + 3 16
16
Optional
Opposed Blade Damper
Opposed
Blade Damper
Economical Square Diffusers
- V-Beveled
Drop Surface Mounting
With Opposed Blade Damper
13
4
Model 5200-2 D
3
1
16 2 8
5
2 32
5
2 32
Optional
Opposed Blade Damper
3
1
16 2 8
1 23
32
1 23
32
Listed Size + 2 11
16
Duct Size
1
Size - 4
3
1
16 2 8
1 23
32
Optional
Opposed Blade Damper
Optional
Opposed Blade Damper
9
16
Listed Size + 3 3
16
Optional
Opposed Blade Damper
1
28
31
1 32
Optional
Opposed Blade D
13
4
9
16
= Duct Size
1
Size - 4
Listed
Size = -Duct
Size
Economical Square
Diffusers
T-bar
Lay-in
Model 5200-6
Listed Size - 1
4
1
28
31
1 32
9
Listed Size = Duct Size
16
+3 3
16
1
ListedFiller
Size -Panel
4
11
Listed Size + 2 16
T-Bar Module = 24 x 24
DCD-58
Size = Duct Size
1
28
3 1
Listed Size
+ 3Size
Listed
16- 4
7
2 16
1
28
11
Listed Size + 2 16
T-Bar Module = 24 x 24
31
1 32
9
16
7
2 16
1
28
Filler
Panel
Filler
Panel
11
Listed Size + 2 16
T-Bar Module = 24 x 24
For more product information visit us at www.metalaire.com Listed Size = Duct Size
1
Listed Size - 4
Optional
13
4
Optional
Opposed Blad
7
2 16
2 7
16 Listed Size + 2 11
16
2 7
16
T-Bar Module = 24 x 24
Listed Size =
Listed Siz
3/2006
S1 - One Way
S3 - Three Way
S4 - Four Way
Available Sizes
6" x 6"
10" x 10"
14" x 14"
18" x 18"
22" x 22"
1. Available Finishes
2. Available Accessories
Standard Finish:
01 White
Optonal Finish:
02 Aluminum
28 Custom Color
8" x 8"
12" x 12"
16" x 16"
20" x 20"
24" x 24"
3. Construction Details
Outlet Size
6x6
8x8
400
225
Neck Velocity
.004
.001
Ps
12 17 14 12 17 14 12 10
Throw
DCD
10 x 10
114
.001
14 12 10 9
12 x 12
100
.001
12 10 8 7
14 x 14
16 x 16
20 x 20
22 x 22
24 x 24
800
450
288
200
147
Neck Velocity
.014
.004
.002
.001
.001
Ps
33 27 23 20 27 22 19 16 23 19 16 14 21 17 14 12 18 15 13 11
Throw
300
Neck Velocity
Ps
Throw
400
Neck Velocity
Ps
Throw
600
Neck Velocity
Ps
Throw
800
Neck Velocity
Ps
Throw
1000
Neck Velocity
Ps
Throw
1200
Neck Velocity
Ps
Throw
1400
Neck Velocity
Ps
Throw
1600
Neck Velocity
Ps
Throw
1800
Neck Velocity
Ps
Throw
2000
Neck Velocity
Ps
Throw
2200
Neck Velocity
Ps
Throw
675
432
300
220
.008
.004
.002
.001
35 30 25 22 35 30 25 22 27 22 19 15 24 20 17 15
900
576
400
294
.019
.008
.004
.002
47 39 32 29 40 34 28 24 35 30 25 22 32 27 22 19
864
600
441
216
.017
.008
.003
.001
52 43 36 32 43 36 30 26 41 34 28 25 30 25 21 19
800
588
450
288
238
200
.018
.008
.005
.002
.001
.001
57 48 40 35 51 43 36 31 47 39 32 29 40 34 28 24 35 29 24 21 33 27 23 20
735
563
360
298
250
.014
.009
.003
.002
.001
63 52 43 38 57 48 40 35 49 41 34 30 40 34 28 25 38 32 26 23
882
675
432
357
300
.019
.012
.004
.002
.001
70 58 48 42 64 53 44 39 55 46 38 33 46 38 32 28 43 36 30 26
787
504
417
350
.014
.005
.003
.002
63 52 43 38 60 50 41 36 51 43 35 31 48 40 33 29
900
576
476
400
.020
.006
.005
.003
76 63 52 46 65 54 45 40 61 51 42 37 57 48 40 35
648
536
450
.006
.011
.006
65 54 45 40 78 65 54 48 76 61 51 45
720
595
500
.007
.008
.004
70 58 48 42 70 58 48 42 66 55 45 40
792
655
550
.014
.009
.005
79 66 55 48 47 62 51 45 70 58 48 42
DCD-59
3/2006
Accessories
Optional Dampers:
Aluminum DA opposed blade dampers shall be provided. Damper shall be adjusted using a handle accessible through the face of the diffuser.
Screwdriver slot operators are not allowed.
DCD
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized
spray stage using an alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
DCD-60
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Available Neck
6"
thru
24"
Air Pattern
Available Finishes
Standard
Standard
Available Options
DA
S4 - Sq. 4-way
01 - White
Options
S1 - Sq. 1-way
SC - Sq. 2-way corner
S2 - Sq. 2-way
S3 - Sq. 3-way
Model
Available Neck
6"
thru
20"
Module
DCD
Available Finishes
Standard
Standard
Available Options
DA
24" x 24"
S4 - Sq. 4-way
01 - White
Options
S1 - Sq. 1-way
SC - Sq. 2-way corner
S2 - Sq. 2-way
S3 - Sq. 3-way
DCD-61
3/2006
Product Details
The 5700 provides a tight horizontal 360
discharge pattern for superior induction
and occupant comfort
DCD
Aluminized Steel
METALAIRE is proud to announce the availability of aluminized steel for our square Directional Ceiling Diffusers. In environments which demand aluminum's
corrosion resistance, the aluminized coated steel offers the protection of aluminum and the strength of steel. The use of aluminized steel results in a product that
ships better and that handle better during installation.
Non - Adjustable
3 58
Earthquake Tab
Latch Tabs
23
8
1
14
DCD-62
3
Neck Size - 16
3 58
1 x 23 1 Ceiling Opening
23 4
4
3
Overall Diffuser = 24 3
4 x 24 4
Neck Size
-1
8
Ceiling Opening = 12 x 12
1
14
1
8 31
4
4 Spring Load
- 81
1 41
1
Neck Size - 81
x 23
T-Bar Module = 24 x 24
3
4
Neck Size
Neck Size - 81
Earthquake Tab
Latch Tabs
Neck Size
=57
8
Overall Face Size = 23
- 81
1
14
x 23 34
T-Bar Module = 24 x 24
T-Bar Panel = 24 x 24
Neck Size
=57
8
Earthquake Tab
1
14
Latch Tabs
3 21
Earthquake Tab
4 21 Latch Tabs
Overa
T-
1
14
13
8
Neck Size - 81
3
Overall Face Size = 23 3
4 x 234
Latch Tabs
Latch Ta
T-Bar Module = 24 x 24
T-Bar Panel = 24 x 24
Earthquake Tab
Earthqua
3
Overall Face Size = 23 3
4 x 234
Neck Size
Overall
T-B
Neck Size - 81
13
8
3 41
13
8
13
8
1 41
5
3
4
3
4
DCD
Earthquake Tab
Tabs
SquareLatch
Face
Diffusers - T-Bar Lay-in - 24" x 24"
Model 5700-6
- Steel
Model 5700-6 AS - Aluminized Steel
Model 5700-6 AL - Aluminum
13
8
3 41
3/2006
T-Bar Panel = 24 x 24
3 21
4 21
Neck Size - 81
Earthquake Tab
Latch Tabs
3 21
4 21
23 38 x 23 38
Earthquake Tab
Latch Tabs
3 21
3 21
Metric
4 21
4 21
3
3
Square Face Diffusers - Metric23- T-bar
8 x 23 8 Lay-in - Steel
Overall
Face Size = 23 34 x 23 34
Model M5700-6 - 600mm
x 600mm
T-Bar
= 24 x 24
Model M5700-6 AS - 600mm
x Module
600mm
Model M5700-6 AL - 600mm x 600mm
Earthquake Tab
Neck Size - 3
Latch Tabs
Earthquake Tab
Latch Tabs
3 21
4 21
Neck Size - 81
95
120
3 21
Overall Face Size = 594 x 594
4 21
23 38 x 23 38
DCD-63
Earthquake Tab
Latch Tabs
DCD
Adjustable
Outer Cone
43
8
1
38
Latch Tabs
1
14
No. 2
Cone
1
Neck Size - 8
Earthquake Tab
43
8
1
38
Outer Cone
T-Bar Module 24 x 24
Earthquake Tab
3/2006
1
14
Adjustable
Deflecting Vanes
3
Ceiling Opening = 23 3
4 x 234
1
1
Overall Face = 25 2 x 25 2
No. 1
Cone
Latch Tabs
1
14
Outer Cone
43
8
1
38
No. 2
Cone
No. 1
Cone
Adjustable
Deflecting Vanes
Overall Face = 23 34 x 23 34
T-Bar Module 24 x 24
Earthquake Tab
Latch Tabs
Neck Size - 1
8
1
14
Outer Cone
43
8
31
8
No. 2
Cone
Earthquake Tab
Latch Tabs
Outer Cone
1. Available Finishes
Standard Finish:
01 White
Optional Finish No. 2
03 Black
Cone
28 Custom color
Adjustable
Deflecting Vanes
No. 1
Cone
Overall Face = 23 34 x 23 34
T-Bar Module 24 x 24
1
Neck Size - 8
1
14
Earthquake Tab
Neck Size - 1
8
Latch Tabs
3. Construction Details
1
43
38
8 Outer Cone
31
8
G3 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . . . . .337
Sizes only as listed
BDS - Butterfly Damper . . . . . . . . . . . . . . . . . . . . . . .335
Available Neck Sizes:
Adjustable
6, 8,2 10, 12, 14 and
151
No. 1
Adjustable
No.
RSD - Radial Shutter Damper . . . . . . . . . . . . . . . . . . .336
No.
Deflecting Vanes
Cone
Deflecting Vanes
Cone
Cone
SNAP 58 - Converts 5700 from 2 to 3 Cones)
BAF3 -x Directional
Baffles
Overall Face = 23
23 3
Overall Face = 23 3 x 23 3
2. Available Accessories
T-Bar ModuleNote:
24 x 24
T-Bar Module 24 x 24
Earthquake Tab
Latch Tabs
Neck Size - 1
8
1
14
Outer Cone
31
8
No. 2
Cone
DCD-64
No. 1
Cone
43
8
Adjustable
Deflecting Vanes
Overall Face = 23 34 x 23 34
T-Bar Module 24 x 24
1
14
43
8
3/2006
12" x 12"
Ak = 0.093
8
Ak = 0.165
Ak = .077
8
Ak = 0.136
10
24" x 24"
Ak = 0.213
12
Ak = 0.307
14
Ak = 0.418
15
Ak = 0.479
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
900
0.050
1000
0.062
CFM
Ps
Pt
Throw*
Throw
NC
140
0.029
0.039
3-4-8
3-5-8
-
175
0.046
0.062
3-5-9
4-6-9
<15
210
0.066
0.089
4-6-10
5-7-10
19
245
0.090
0.121
5-7-11
6-7-11
22
280
0.118
0.158
5-8-11
7-8-11
25
315
0.149
0.199
6-8-12
7-8-12
28
350
0.184
0.246
7-9-13
7-9-13
31
CFM
Ps
Pt
Throw*
Throw
NC
140
0.016
0.026
2-3-6
3-5-10
-
175
0.025
0.040
3-4-7
4-6-11
-
210
0.036
0.058
3-5-7
5-7-12
-
280
0.063
0.103
4-6-9
6-10-14
<15
315
0.080
0.131
5-6-9
7-10-15
18
350
420
490
700
0.099
0.142
0.194
0.395
0.161
0.232
0.316
0.645
5-7-10 6-7-10
7-8-11 8-10-13
8-11-16 10-12-17 11-13-18 13-16-22
21
26
30
55
CFM
Ps
Pt
Throw*
Throw
NC
315
0.021
0.031
3-5-9
5-7-15
-
395
0.033
0.048
4-6-10
6-9-17
-
470
0.046
0.069
5-7-11
7-11-18
-
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
80
0.021
0.031
2-3-6
3-4-6
-
80
0.014
0.024
2-2-5
2-4-7
-
100
0.033
0.049
3-4-7
3-5-7
<15
100
0.021
0.037
2-3-5
3-5-8
-
220
0.019
0.029
3-4-8
4-6-12
-
275
0.030
0.046
3-5-8
5-8-14
-
430
0.026
0.036
4-6-11
6-9-17
-
535
0.041
0.056
5-7-12
7-11-19
-
490
0.032
0.042
4-6-11
6-9-18
-
615
0.051
0.066
5-8-13
8-11-21
-
120
0.048
0.071
3-5-7
4-5-7
18
135
0.061
0.091
3-5-8
4-6-8
20
120
0.031
0.053
2-4-6
4-6-9
-
135
0.039
0.069
3-4-6
4-6-10
-
325
0.042
0.064
4-6-9
6-9-15
-
380
0.057
0.088
5-7-10
7-11-16
<15
245
0.048
0.079
4-6-8
6-9-13
-
155
0.080
0.120
4-6-8
5-6-8
23
155
0.051
0.091
3-4-6
5-7-10
<15
435
0.075
0.115
5-8-11
8-12-17
16
175
0.102
0.153
4-6-9
5-6-9
26
175
0.065
0.116
4-5-7
5-8-11
16
195
0.127
0.189
5-7-9
5-7-9
28
195
0.081
0.143
4-5-7
6-8-12
18
1200
0.090
235
0.184
0.274
6-7-10
6-7-10
33
420
0.265
0.354
8-10-14
8-10-14
36
235
0.118
0.207
5-6-8
7-9-13
23
1400
0.122
275
0.253
0.375
6-8-11
6-8-11
36
2000
0.249
395
0.521
0.770
8-9-13
8-10-13
44
490
700
0.360
0.735
0.482
0.984
9-11-15 10-13-18
9-11-15 10-13-18
40
46
275
395
0.161
0.332
0.283
0.582
5-6-8
6-7-10
8-10-14 10-12-17
27
43
DCD
Listed
Size
Models 5700 (-1, -6, -7, -9), 5700-6P, 5700 AS (-1,-6,-7,-9), 5700 AL (-1, -6), 5700A (-1, -6, -7), 5700A-1, 5700A-6P
490
545
655
765
1090
0.096
0.118
0.171
0.233
0.473
0.146
0.181
0.261
0.355
0.722
6-8-11
7-8-12 8-9-13 8-10-14 10-12-17
9-13-18 10-14-19 12-15-21 13-16-23 16-19-28
20
24
30
35
63
550
630
705
785
940
1100
1570
0.063
0.083
0.104
0.129
0.185
0.253
0.515
0.094
0.123
0.154
0.191
0.274
0.375
0.765
6-8-12 7-9-13 7-10-14 8-10-14 9-11-16 10-12-17 12-14-20
8-13-20 10-15-21 11-16-22 12-17-23 14-18-26 16-20-28 19-23-33
<15
19
23
27
33
39
68
640
750
855
960
1070
1285
1495
2140
0.058
0.080
0.104
0.131
0.163
0.234
0.317
0.650
0.081
0.110
0.144
0.181
0.225
0.324
0.440
0.900
6-9-13 7-10-14 8-11-15 9-11-16 10-12-17 11-13-18 11-14-20 14-17-24
8-13-21 10-15-23 11-17-24 13-18-26 14-19-27 17-21-30 19-23-32 22-27-39
<15
<15
18
23
28
35
40
57
735
860
980
1105
1225
1475
1720
2455
0.072
0.099
0.129
0.164
0.201
0.292
0.396
0.808
0.095
0.130
0.169
0.214
0.263
0.381
0.519
1.057
6-9-14 7-11-15 8-11-16 9-12-17 10-13-18 11-14-20 12-15-21 15-18-25
9-14-23 11-16-24 12-18-26 14-20-28 15-21-29 18-23-32 20-24-35 24-29-41
<15
16
22
27
31
39
46
68
DCD-65
3/2006
Surface Mount
T-bar Lay-in
Concealed Spline
Donn Fineline Lay-in
DCD
Units shall be square with a formed backpan and two inner cones. Outlet shall have the same appearance from the face regardless of inlet size. The units
shall be the size and quantity as outline in the plans and specifications.
Inlets shall be drawn into the backpan of the diffuser. Welded inlets are not acceptable. Diffusers shall include seismic tabs drawn into the backpan. Inner
cone assemble shall be removable without the aid of tools for installation and to access optional damper. Units requiring tools such as screwdrivers or hex
keys to remove the inner cones are not acceptable.
The bottom cone shall have a removable plug in the center to allow access to adjust an optional damper. Units shall include the option to allow a field
installed third optional cone accessory model Snap-58. Optional third cone shall be installed into the bottom of the 5700 diffuser without the use of tools.
Units shall be designed to integrate into the specified ceiling system.
Optional for Adjustable Pattern
Outlet shall include adjustable deflector blades located within the cones of the device. Deflectors shall allow the discharge air to be adjusted to obtain a
vertical or horizontal air pattern.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
.8-1.0 mils
Film Cure
DCD-66
Performance
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Available Neck
Module
Available Finishes
Standard
5700-1
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
01 - White
Optional
10"
12" x 12"
12"
24" x 24"
DCD
Model
Available Neck
Module
Available Finishes
Standard
5700-7
01 - White
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
6"
5700-7 AS
5700A-7
RSD
03 - Black
Optional
BAF-1
28 - Custom Color
BAF-2
BAF-3
8"
10"
5700A-7 AS - Adjustable T-bar Lay-in - Aluminized
24" x 24"
12"
Steel
14"
5700-9
5700-9 AS
15"
Model
Available Neck
Module
Available Finishes
Standard
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
01 - White
6"
Optional
8"
M5700-6
600mm x 600mm
12"
DCD-67
3/2006
DCD
Aluminized Steel
METALAIRE is proud to announce the availability of aluminized steel for our square Directional Ceiling Diffusers. In environments which demand aluminum's
corrosion resistance, the aluminized coated steel offers the protection of aluminum and the strength of steel. The use of aluminized steel results in a product that
ships better and that handle better during installation.
Latch Tabs
Ceiling
Line
DCD-68
1
Neck Size - 8
1 81
Earthquake Tab
1
8
1
22
Ceiling Line
1
Neck Size - 8
181
Ceiling Opening = 12 x 12
Overall Face = 13 x 13
Earthquake Tab
Air Diffusion Panel
Mounting Post
1
8
7
8
1
18
1
2
Overall Face = 23 4 x 23 4
T-Bar Module = 12 x 12
T-Bar Module = 24 x 24
T-Bar By
Others
Neck Size - 1
8
Latch Tabs
1 81
1
Neck Size - 8
Earthquake Tab
1
22
Air Diffusion Panel = 18 x 18
3
Overall Face = 23 3
4 x 23 4
T-Bar Module = 24 x 24
1
Neck Size - 8
Latch Tabs
1 81
1
18
7
8
Overall Face = 11 34 x 11 34
T-Bar Module = 12 x 12
T-Bar By
Others
1 81
Earthquick Tab
Narrow T-Bar
By Others
Earthquake Tab
1
Neck Size - 8
Latch Tabs
DCD
3/2006
1 81
Earthquake Tab
1
22
1
22
Narro
B
Metric
Neck Size - 3
Latch Tabs
T-Bar By
Others
T-Bar By Others
Latch Tabs
1
Neck Size - 8
1 81
28
64
1
22
Narrow T-Bar
By Others
Latch Tabs
1. Available Finishes
Standard Finish:
01 White
Optional Finish
03 Black
28 Custom color
1
Neck Size - 8
Earthquake Tab
Earthquake Tab
2. Available Accessories
G3 - Equalizing Grid . . . . . . . . . . . . . . . .337
BDS - Butterfly Damper . . . . . . . . . . . . .335
RSD - Radial Shutter Damper . . . . . . . . .336
BAF - Directional Baffles
BO - Blank off for 5750
1 81
Nar
Earthquake Tab
1
22
Air Diffusion Panel = 18 x 18
3
Overall Face = 23 3
4 x 23 4
T-Bar Module = 24 x 24
3. Construction Details
Sizes only as listed
Available Neck Sizes:
6" and 8" for 12" x 12" Module
6", 8", 10", 12", 14", and 15" for
24" x 24" Module.
Note:
All Accessories Shipped Unattached
DCD-69
3/2006
Models 5750 (-1, -2, -7, -9) 5750 AS (-1, -6, -7, -9)
Listed
Size
12" x 12"
Ak = 0.093
8
Ak = 0.165
6
DCD
Ak = .077
8
Ak = 0.136
10
24" x 24"
Ak = 0.213
12
Ak = 0.307
14
Ak = 0.418
15
Ak = 0.479
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
CFM
Ps
Pt
Throw*
Throw
NC
140
0.017
0.027
3-5-9
4-6-9
<15
175
0.027
0.043
4-7-10
5-7-10
<15
210
0.039
0.061
5-8-11
6-8-11
17
245
0.053
0.083
6-8-11
7-8-12
20
280
0.069
0.109
7-9-12
7-9-13
22
CFM
Ps
Pt
Throw*
Throw
NC
140
0.007
0.017
1-1-6
1-2-6
<15
175
0.012
0.027
1-2-7
2-4-8
<15
210
0.017
0.039
1-3-9
2-5-10
<15
245
0.023
0.053
2-4-10
3-6-11
17
CFM
Ps
Pt
Throw*
Throw
NC
315
0.027
0.037
1-2-9
2-4-10
<15
395
0.042
0.058
1-3-11
2-6-12
<15
470
0.059
0.082
2-5-13
4-7-14
17
CFM
Ps
Pt
Throw*
Throw
NC
490
0.038
0.048
1-3-11
2-4-12
<15
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
80
0.009
0.019
3-4-7
3-4-7
<15
80
0.003
0.013
0-1-4
1-2-5
<15
100
0.014
0.030
3-5-7
4-5-7
<15
100
0.004
0.020
1-2-6
1-3-6
<15
220
0.016
0.026
1-2-7
1-3-8
<15
275
0.025
0.040
1-3-9
2-5-10
<15
430
0.031
0.041
1-3-10
2-4-11
<15
535
0.049
0.064
2-4-13
3-6-14
<15
615
0.060
0.076
2-4-14
3-7-15
<15
120
0.021
0.043
4-6-8
4-6-8
<15
120
0.006
0.029
1-2-7
2-4-7
<15
325
0.034
0.056
2-4-11
3-6-12
15
640
0.069
0.092
2-6-15
4-8-17
20
735
0.086
0.108
3-6-16
4-9-18
20
135
0.024
0.054
4-6-9
5-6-9
16
900
0.050
155
0.032
0.072
5-6-9
5-7-9
18
175
0.041
0.092
6-7-10
6-7-10
21
155
0.008
0.048
2-4-8
3-5-9
15
175
0.011
0.061
2-5-9
4-5-9
18
1000
0.062
195
0.051
0.114
6-7-10
6-7-10
23
1200
0.090
1400
0.122
2000
0.249
235
0.075
0.165
6-8-11
7-8-11
27
275
0.104
0.226
7-9-12
7-9-12
31
315
0.137
0.297
8-9-13
8-9-13
34
235
0.021
0.110
4-7-10
5-7-11
26
275
0.029
0.151
5-8-11
6-8-12
31
315
0.039
0.198
6-9-12
6-9-13
35
315
0.087
0.138
8-9-13
8-9-13
25
350
0.108
0.170
8-10-14
8-10-14
27
420
490
560
0.155
0.212
0.276
0.245
0.334
0.436
9-11-15 9-11-16 10-12-17
9-11-15 10-12-17 10-13-18
31
34
37
280
0.030
0.070
3-6-11
4-6-12
21
315
0.038
0.088
3-7-12
5-7-13
25
350
0.047
0.109
4-7-13
5-8-13
28
420
0.067
0.157
6-9-14
6-10-14
34
550
0.081
0.112
3-7-15
5-8-17
22
630
0.107
0.146
4-9-17
6-10-18
27
705
0.133
0.183
5-10-18
7-11-19
30
860
0.117
0.148
4-8-19
6-10-21
27
980
0.152
0.192
5-11-21
8-12-22
32
1105
1225
1475
1720
1965
0.194
0.238
0.345
0.469
0.613
0.244
0.300
0.435
0.592
0.772
6-12-23 7-14-24 11-17-26 13-19-28 15-21-30
9-13-24 10-15-25 12-18-27 14-21-29 16-22-31
35
37
41
44
47
135
0.006
0.036
1-3-8
2-4-8
<15
380
0.047
0.077
2-5-13
4-7-14
21
750
0.095
0.126
3-8-18
6-10-19
25
435
0.061
0.101
3-7-14
5-8-15
26
855
0.124
0.164
4-10-20
7-11-21
30
195
0.014
0.076
3-5-9
4-6-10
21
655
0.139
0.229
7-11-17
8-12-18
37
490
0.091
0.213
7-10-15
7-11-16
39
560
0.119
0.279
8-11-16
9-12-17
42
765
875
0.190
0.249
0.313
0.409
9-13-19 10-14-20
9-14-20 11-15-21
41
43
490
0.078
0.128
4-8-15
6-9-16
30
545
0.096
0.159
5-9-16
7-10-17
33
960
0.156
0.206
6-12-21
8-13-22
33
1070
1285
1495
1710
0.194
0.280
0.378
0.495
0.256
0.370
0.501
0.655
7-13-22 10-15-24 12-18-26 14-20-28
9-14-23 11-17-25 13-19-27 15-21-29
36
40
43
46
785
940
1100
1255
0.165
0.236
0.324
0.422
0.227
0.326
0.446
0.581
6-11-19 8-13-21 10-15-23 12-17-24
8-12-20 10-14-22 11-17-23 13-18-25
33
38
42
45
DCD-70
3/2006
5750-1
5750-6
5750-7
5750-9
Surface Mount
T-bar Lay-in
Concealed Spline
Donn Fineline Lay-in
DCD
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
DCD-71
3/2006
Available Neck
Module
Available Finishes
Standard
5750-1
5750-1 AS
Steel
5750-6
5750-6 AS
DCD
Square Face Diffusers - Round Neck - Uni-Flo Panel Face - Series 5750
Model
6"
8"
10"
12"
14"
15"
Available Neck
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
BO
Blank-Off
D3
SD3
01 - White
12" x 12"
24" x 24"
Module
Options
Available Finishes
Standard
5750-7
5750-7 AS
Steel
5750-9
5750-9 AS
Model
6"
8"
10"
12"
14"
15"
Available Neck
Available Options
01 - White
24" x 24"
Options
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
BO
Blank-Off
D3
SD3
Module
Available Finishes
Standard
M5750-6
- Metric T-bar Lay-in - Steel
M5750-6 AS - Metric T-bar Lay-in - Aluminized
Steel
DCD-72
6"
8"
10"
12"
14"
15"
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
BO
Blank-Off
D3
SD3
01 - White
600mm x 600mm
Available Options
G3
Options
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
DCD
3/2006
Aluminized Steel
METALAIRE is proud to announce the availability of aluminized steel for our square Directional Ceiling Diffusers. In environments which demand aluminum's
corrosion resistance, the aluminized coated steel offers the protection of aluminum and the strength of steel. The use of aluminized steel results in a product that
ships better and that handles better during installation.
Non-Adjustable
1
22
1
14
Neck Size - 1
8
3 21
1 x 23 1 Ceiling Opening
23 4
4
3
Overall Diffuser = 24 3
4 x 24 4
DCD-74
43
4
4 Spring Loaded
Latches
Neck Size
-1
8
1
14
Ceiling Opening = 12 x 12
Overall Face Size = 13 x 13
1
18
1
8 31
2
43
4
1
22
ck Size - 1/8
1
3 1/2
14
4 3/4
Neck Size
1
Neck Size - 8
3 21
43
4
1 1/4
1 41
1 81 3 1
2
1 1/8 3 1/2
23
3 x 23 3
4
4
T-Bar Module = 24 x 24
Available Neck Sizes 6, 8, 10, 12, 14, 15
3/4 x 23 3/4
-81
Neck Size
-1/8
1
2
3/2006
odule = 24 x 24
T-Bar Module = 12 x 12
2, 14, 15
DCD
Square Face - Round Neck - 3 Cone - T-bar Lay-in Panel - 24" x 24"
Model 5800-6P - Steel
5 7/8
1 1/4
57
8
Metric
1
14
Latch Tabs
8
3 1/2
Neck Size - 81
Earthquake Tab
Neck Size
- 1/8
Earthquake
3 21
4 3/4
3
4
vailable N
3/4 x 23 3/4
x 24
T-Bar Module = 12 x 12
Available Neck Sizes 6, 8
15
Neck Size
-81
1 41
1 81
3 21
DCD-75
3/2006
DCD
Adjustable
Ceiling Opening = 23 21 x 23 21
Pattern Controller
Settings For Sizes
6/24, 8/24, 10/24
and 12/24
Ceiling Line
Slot Pocked
Outer
Cone
No. 3
Cone
For Vertical
Downward Pattern
No. 2
Cone
For Vertical
Downward Pattern
Pattern Controller
Settings For Sizes
14/24 and 15/24
1
14
Neck Size - 81
No. 1 Cone
1
8
For Horizontal
Pattern
4 38
3
8
1
14
Pattern Controller
Settings For Sizes
6/24, 8/24, 10/24
and 12/24
T-Bar
By Others
Slot Pocked
Outer
Cone
For Vertical
Downward Pattern
For Horizontal Pattern
3. Construction Details
Note:
All Accessories Shipped Unattached
Pattern Controller
Settings For Sizes
6/24, 8/24, 10/24
and 12/24
T-Bar
By Others
Slot Pocked
Outer
Cone
No. 3
Cone
For Vertical
Downward Pattern
For Horizontal Pattern
1
14
Neck Size - 81
No. 2
Cone
Pattern ControllerSettings
For Sizes 14/24 and 15/24
For Vertical
Downward Pattern
No. 1 Cone
For Horizontal
Pattern
43
4
1
14
3
8
T-Bar Module = 24 x 24
DCD-76
No. 2
Cone
Pattern ControllerSettings
For Sizes 14/24 and 15/24
For Vertical
Downward Pattern
No. 1 Cone
For Horizontal
Pattern
T-Bar Module = 24 x 24
2. Available Accessories
Standard Finish:
01 White
Optional Finish
03 Black
28 Custom color
1
14
Neck Size - 81
1. Available Finishes
No. 3
Cone
43
4
1
14
3
8
3/2006
12" x 12"
Ak = 0.093
8
Ak = 0.165
6
Ak = .077
8
Ak = 0.136
10
24" x 24"
Ak = 0.213
12
Ak = 0.307
14
Ak = 0.418
15
Ak = 0.479
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
900
0.050
1000
0.062
CFM
Ps
Pt
Throw*
Throw
NC
140
0.026
0.036
3-5-8
3-5-8
-
175
0.041
0.056
4-6-9
4-6-9
<15
210
0.059
0.081
5-7-10
5-7-10
19
245
0.080
0.110
6-8-11
6-8-11
22
280
0.104
0.144
7-8-11
6-8-11
25
315
0.132
0.182
7-9-12
7-9-12
28
350
0.163
0.225
7-9-13
7-9-13
30
CFM
Ps
Pt
Throw*
Throw
NC
140
0.014
0.024
4-5-7
4-5-10
-
175
0.022
0.038
5-6-8
4-7-11
-
210
0.032
0.054
5-6-9
5-8-12
-
280
0.056
0.096
6-7-10
7-10-14
17
315
0.071
0.122
6-7-11
8-10-15
21
350
420
490
560
0.088
0.126
0.172
0.225
0.150
0.216
0.294
0.384
6-8-11
7-9-12 8-9-13 8-10-14
9-11-15 10-12-17 10-13-18 11-14-19
24
30
34
35
CFM
Ps
Pt
Throw*
Throw
NC
315
0.022
0.032
6-7-11
5-8-15
-
395
0.035
0.050
7-8-12
7-10-16
-
490
0.036
0.046
7-9-13
7-10-18
-
615
735
860
980
1105
1225
1475
1720
1965
0.056
0.080
0.109
0.142
0.181
0.222
0.322
0.438
0.571
0.072
0.102
0.140
0.182
0.231
0.284
0.412
0.560
0.731
9-10-15 9-11-16 10-12-17 11-13-19 11-14-20 12-15-21 13-16-23 14-17-25 15-19-26
8-12-20 10-15-22 12-17-24 13-18-26 15-19-27 17-20-29 18-22-32 20-24-34 21-26-36
<15
18
23
29
33
41
46
49
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
CFM
Ps
Pt
Throw*
Throw
NC
80
0.026
0.036
3-4-6
2-4-6
-
80
0.013
0.023
3-4-5
3-4-7
-
220
0.018
0.028
5-6-9
4-7-12
-
430
0.032
0.042
7-9-12
6-9-17
-
100
0.040
0.056
3-5-7
3-5-7
<15
100
0.020
0.036
3-4-6
3-5-8
-
120
0.058
0.080
4-5-7
4-5-7
18
135
0.073
0.104
4-6-8
4-6-8
21
155
0.097
0.137
5-6-8
5-6-8
24
195
0.076
0.139
5-6-8
7-8-11
21
235
0.223
0.312
6-7-10
6-7-10
33
420
0.235
0.324
8-10-14
8-10-14
34
235
0.111
0.201
5-6-9
7-9-13
25
275
0.305
0.427
6-8-11
6-8-11
35
490
0.319
0.442
9-11-15
9-11-15
37
275
0.152
0.274
6-7-10
8-10-14
28
2000
0.249
315
0.400
0.559
7-9-12
7-9-12
37
560
0.417
0.577
9-11-16
9-11-16
40
135
0.037
0.067
4-5-7
5-7-10
<15
275
0.028
0.043
6-7-10
6-8-14
-
325
0.039
0.061
6-8-11
7-10-15
-
380
0.053
0.084
7-8-12
8-11-16
<15
535
0.049
0.065
8-10-14
8-12-19
-
640
750
855
960
1070
1285
1495
1710
0.071
0.097
0.126
0.159
0.198
0.285
0.386
0.505
0.093
0.128
0.166
0.210
0.260
0.375
0.508
0.665
9-11-15 9-12-16 10-12-17 11-13-18 11-14-19 12-15-21 13-16-23 14-17-25
9-14-21 11-16-22 12-17-24 14-18-25 15-19-27 17-21-29 18-22-32 20-24-34
<15
17
22
27
32
39
44
47
470
0.049
0.072
7-9-13
8-12-18
<15
175
0.061
0.112
5-6-8
6-8-11
18
195
0.153
0.216
5-7-9
5-7-9
29
1400
0.122
120
0.029
0.051
4-5-7
4-6-9
-
245
0.043
0.074
5-7-9
6-9-13
<15
155
0.048
0.088
4-5-7
5-7-10
<15
175
0.123
0.174
5-6-9
5-6-9
26
1200
0.090
Listed
Size
315
0.199
0.359
6-7-11
8-10-15
31
DCD
Models 5800 (-1, -6, -7), 5800-6P, 5800 AS (-1,-6, -7), 5800 AL (-1, -6)
435
490
545
655
765
875
0.070
0.088
0.109
0.158
0.215
0.282
0.110
0.139
0.172
0.248
0.337
0.441
7-9-12 8-9-13 8-10-14 9-11-15 9-12-16 10-12-18
9-12-17 10-13-18 11-14-19 12-15-21 13-16-23 14-17-24
19
23
27
33
38
40
550
630
705
785
940
1100
1255
0.067
0.088
0.111
0.137
0.197
0.270
0.351
0.098
0.128
0.161
0.200
0.287
0.392
0.511
8-10-14 9-11-15 9-11-16 10-12-17 11-13-18 11-14-20 12-15-21
9-14-19 11-15-21 12-15-22 13-16-23 15-18-25 16-19-27 17-21-29
16
21
26
30
36
41
43
DCD-77
3/2006
Surface Mounted
T-bar Lay-in
Concealed Spline
Donn Fineline Lay-in
DCD
Units shall be square with a formed backpan and three inner cones. Outlet shall have the same appearance from the face regardless of inlet size. The units
shall be the size and quantity as outline in the plans and specifications.
Optional for Adjustable Pattern
Inlets shall be drawn into the backpan of the diffuser. Welded inlets are not acceptable. Diffusers shall include seismic tabs drawn into the backpan. Inner
cone assemble shall be removable without the aid of tools for installation and to access optional damper. Units requiring tools such as screwdrivers or hex
keys to remove the inner cones are not acceptable.
The bottom cone shall have a removable plug in the center to allow access to adjust an optional damper.
Units shall be designed to integrate into the specified ceiling system.
Outlet shall include adjustable deflector blades located within the cones of the device. Deflectors shall allow the discharge air to be adjusted to obtain a
vertical or horizontal air pattern.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
DCD-78
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Model
Available Neck
Module
Available Finishes
Standard
5800-1
01 - White
Options
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
D3
SD3
10"
12" x 12"
12"
24" x 24"
DCD
Model
Available Neck
Module
Available Finishes
Standard
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
D3
SD3
01 - White
6"
Options
5800-7
8"
5800-7 AS
10"
5800A-7
12"
24" x 24"
14"
15"
Model
Available Neck
Module
Available Finishes
Standard
01 - White
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
6"
RSD
03 - Black
Options
BAF-1
28 - Custom Color
BAF-2
BAF-3
D3
SD3
8"
M5800-6
600mm x 600mm
12"
DCD-79
3/2006
Aluminized Steel
METALAIRE is proud to announce the availability of aluminized steel for our square Directional Ceiling Diffusers. In environments which demand aluminum's
corrosion resistance, the aluminized coated steel offers the protection of aluminum and the strength of steel. The use of aluminized steel results in a product that
ships better and that handle better during installation.
1
Neck - 8
Earthquake Tab
1
14
on Panel = 18 x 18
Opening = 24 x 24
3
Face = 243
4 x 244
Latch Tabs
Ceiling
Line
DCD-80
1
8
1
22
1
Neck - 8
1
14
Earthquake Tab
1
8
1
22
T-Bar By Others
Latch Tabs
1
Neck - 8
Earthquake Tab
T-Bar By Others
1
12
Overall Face = 23 34 x 23 34
T-Bar Spacing = 24 x 24
Latch Tabs
Ove
T-B
Concealed
T-Bar By Others
Earthquake Tab
Latch Tabs
1
Neck - 8
Narow T-Bar
By Others
Earthquake Tab
Latch Tabs
7
Overall Face 23 7
8 x 23 8
7
ace 23 7
8 x 23 8
Narow T-Bar
By Others
T-Bar Spacing = 24 x 24
T-Bar Spacing 24 x 24
pacing 24 x 24
1
Neck - 8
Metric
Earthquake Tab
Latch Tabs
DCD
1
Neck - 8
3/2006
Earthquake Tab
Neck - 3
Latch Tabs
T-Bar By Others
38
Overall Face = 594 x 594
T-Bar Spacing = 600 x 600
1. Available Finishes
Standard Finish:
01 White
Optional Finish
03 Black
28 Custom color
2. Available Accessories
G3 - Equalizing Grid . . . . . . . . . . . . . . . .337
BDS - Butterfly Damper . . . . . . . . . . . . .335
RSD - Radial Shutter Damper . . . . . . . . .336
BO - Blank off
3. Construction Details
Sizes only as listed
Available Neck Sizes:
6", 8", 10", 12", 14", and 15"
Note:
All Accessories Shipped Unattached
DCD-81
T-B
3/2006
DCD
Model Phenom (-1, -6, -7, -9), Phenom AS (-1, -6, -7, -9)
Nominal
Neck Size
6"
8"
10"
12"
14"
15"
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
900
0.050
1000
0.062
1200
0.090
140
0.020
0.030
1-2-3
1-1-2
<20
175
0.031
0.047
2-3-5
1-2-4
21
210
0.045
0.067
2-5-6
1-4-5
25
245
0.061
0.092
3-6-7
2-5-6
29
280
0.080
0.114
4-6-8
3-5-7
32
315
0.101
0.151
5-7-10
4-6-9
35
350
0.125
0.187
6-8-12
5-7-10
37
385
0.152
0.218
7-9-13
6-7-11
40
315
0.061
0.071
4-7-11
3-6-10
22
220
0.036
0.046
4-6-9
3-5-7
20
275
0.080
0.096
6-8-10
5-7-9
24
395
0.096
0.112
7-10-13
6-9-12
27
120
0.020
0.042
1-1-2
1-1-1
<20
325
0.090
0.110
7-9-12
5-8-11
27
135
0.026
0.057
1-2-3
1-1-2
20
380
0.108
0.139
8-10-13
6-9-12
31
155
0.034
0.074
2-2-4
1-1-3
21
435
0.142
0.182
8-10-14
7-9-13
35
175
0.044
0.094
2-3-5
1-2-4
24
195
0.054
0.116
3-4-6
2-3-5
26
215
0.066
0.141
3-5-7
3-4-6
29
490
545
600
0.180
0.223
0.270
0.300
0.285
0.345
9-12-16 11-14-17 12-15-18
8-11-15 10-13-15 11-13-17
38
41
44
470
550
630
705
785
870
0.136
0.186
0.240
0.306
0.380
0.423
0.156
0.217
0.280
0.356
0.442
0.495
9-11-14 11-13-16 13-15-18 15-18-20 16-20-22 18-21-24
7-10-13 9-11-14 11-14-16 12-15-18 13-17-20 15-19-22
32
36
40
43
46
52
-12
Watts.
Surface Mount
T-bar Lay-in
Concealed Spline
Donn Fineline Lay-in
DCD-82
3/2006
Butterfly Damper
METALAIRE model BDS aluminum round butterfly type dampers shall be provided. Damper shall consist of two butterfly style blades that can be adjusted
from full open to full closed. Damper shall be adjusted with a screw driver slot.
Radial Shutter Damper
METALAIRE model RSD steel round radial shutter damper shall be provided. Damper shall consist of gang operated radial blades that slide perpendicular
to air flow direction. The damper shall be adjusted from full open to full closed. Damper shall be adjusted with a screw driver slot.
Opposed Blade Damper
METALAIRE model D3 aluminum or SD3 steel round opposed blade type dampers shall be provided. Damper shall consist of gang operated blades that
can be adjusted from full open to full closed. Damper shall be adjusted with a screw driver slot.
Equalizing Grid
METALAIRE model G3 aluminum round equalizing grid shall be provided. Equalizing grid shall consist of 1/2" x 1/2" x 1/2" aluminum cubed core mounting
in an aluminum frame.
Performance Specification
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
DCD
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Available Neck
Module
Available Finishes
Standard
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
D3
SD3
01 - White
6"
Options
Phenom-1
8"
10"
Phenom-6
12"
24" x 24"
- T-bar Lay-in - Steel
14"
15"
Model
Available Neck
Module
Available Finishes
Standard
01 - White
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
6"
Options
Phenom-7
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
BAF-3
D3
SD3
8"
10"
24" x 24"
12"
14"
Phenom-9
15"
Model
Available Neck
Module
Available Finishes
Standard
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
BAF-1
28 - Custom Color
BAF-2
14"
BAF-3
15"
BO
Blank Off
D3
SD3
01 - White
Options
6"
8"
MPhenom-6
10"
600mm x 600mm
MPhenom-6 AS - Metric T-bar Lay-in - Aluminized Steel
Available Options
12"
DCD-83
3/2006
DCD
Ceiling Opening
3
16
Dimension from bottom
of duct to ceiling line
1
4
T-Bar without
Panel (6A)
Beveled (2)
Tegular (8)
Concealed (7)
Duct Connection
(S4 Shown)
DCD-84
-Supply
T-Bar with
Panel (6B)
-Return
3/2006
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
24 Mill finish
28 Custom color
Note:
Anodized Finish not available
1. Available Finishes
BASED ON 100% RETURN OF SUPPLY AIR FOR 2 - 10 TON ROOF TOP PACKAGES
CAPACITY (CFM)
2 1/2
21 x 21
21 x 21
800
1000
.60
1335
.09
.11
7-14
.60
1665
.15
.18
8-16
1200
24 x 24
.70
1715
.15
.18
9-17
1600
27 x 27
1.10
1430
.11
.13
10-20
7 1/2
30 x 30
39 x 39
2000
10
3000
1.30
1575
.13
.15
12-23
4000
45 x 45
2.20
1365
.10
.12
16-31
DCD
TONNAGE
2.60
1540
.12
.15
21-39
1.56
513
.04
25
1.56
640
.06
35
2.25
535
.04
37
2.25
710
.07
30
3.06
654
.06
37
5.06
590
.05
37
7.56
529
.04
38
BASED ON 100% RETURN OF SUPPLY AIR FOR 2 - 10 TON ROOF TOP PACKAGES
SIDE DESIGNATION
CAPACITY (CFM)
800
24 x 18
Ak
Vk
Ps
Pt
THROW
.60
1335
.09
.11
6-11 8-14
Ak
INLET VELOCITY
Ps
NC
1.50
533
.04
25
18 x 12
2 1/2
1000
1200
1600
2000
7 1/2
3000
10
4000
27 x 18
27 x 21
36 x 21
36 x 27
45 x 36
54 x 36
21 x 12
21 x 15
27 x 12
27 x 18
33 x 24
42 x 24
.65
.70
1.20
1.35
2.30
2.60
1540
1715
1335
1480
1300
1540
.12
.15
.09
.12
.09
.12
.15
.18
.11
.14
.11
.15
7-12 11-15 8-13 10-16 10-15 12-18 12-14 14-21 15-22 17-25 16-24 19-31
1.75
570
.05
35
2.18
550
.04
37
2.25
710
.07
30
3.38
590
.05
37
5.50
545
.04
32
7.00
570
.05
38
DCD-85
ALL
SUPPLIES
12" x 12"
SUPPLY
Ak = .18
9" x 9"
RETURN
Ak = .56
DCD
15" x 15"
SUPPLY
Ak = .40
9" x 9"
RETURN
Ak = .56
18" x 18"
SUPPLY
Ak = .50
12" x 12"
RETURN
Ak = 1.00
18" x 18"
SUPPLY
Ak = .28
15" x 15"
RETURN
Ak = 1.56
21" x 21"
SUPPLY
Ak = .60
15" x 15"
RETURN
Ak = 1.56
24" x 24"
SUPPLY
Ak = .70
18" x 18"
RETURN
Ak = 2.25
27" x 27"
SUPPLY
Ak = 1.10
18" x 18"
RETURN
Ak = 2.25
200
300
90
2-4
130
3-5
FACE VELOCITY
Ps
Pt
500
.013
.016
TOTAL CFM
INLET VELOCITY
Ps
NC
70
125
.01
-
TOTAL CFM
THROW
TOTAL CFM
THROW
200
3-5
TOTAL CFM
THROW
250
3-5
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW
150
265
.01
-
190
190
.01
140
4-6
2000
.21
.25
100
180
.01
-
130
230
.01
21
165
295
.01
26
200
355
.02
31
230
410
.03
35
260
465
.04
39
TOTAL CFM
THROW
TOTAL CFM
INLET VELOCITY
Ps
NC
560
3-5
405
180
.01
-
175
5-8
220
6-10
265
6-12
310
7-13
350
8-14
300
5-8
400
6-10
500
6-12
600
7-14
700
8-17
800
10-19
375
4-8
500
6-11
625
6-12
750
8-14
875
9-16
1000
10-19
210
5-8
280
6-12
350
7-13
420
8-15
490
9-17
560
11-20
450
4-8
600
5-12
750
7-13
900
8-15
1050
9-17
1200
11-20
525
4-8
700
5-11
875
6-13
1050
8-16
1225 1400
10-20 13-25
845
5-10
1125
7-15
1405
8-17
225
400
.02
-
280
280
.01
-
340
220
.01
-
260
115
.01
-
800
1750
.16
.19
225
145
.01
-
TOTAL CFM
INLET VELOCITY
Ps
NC
700
1500
.12
.14
TOTAL CFM
INLET VELOCITY
Ps
NC
350
3-5
600
1250
.08
.10
155
100
.002
-
TOTAL CFM
THROW
500
1000
.05
.06
105
70
.001
300
3-5
400
Air Pattern
Diagram
750
.03
.04
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW
NECK VELOCITY
395
175
.01
-
610
270
.01
-
300
535
.04
21
375
375
.02
24
210
135
.003
20
450
290
.01
25
525
235
.01
26
815
360
.02
26
375
670
.06
26
470
470
.03
29
260
165
.005
25
560
360
.02
30
655
290
.01
31
1015
450
.03
32
450
805
.09
35
560
560
.04
34
315
200
.007
30
675
430
.03
35
790
350
.02
36
1220
540
.04
37
525
935
.12
40
655
655
.06
38
365
235
.009
35
790
505
.04
39
600
1070
.16
45
750
750
.08
42
420
270
.01
40
900
575
.05
43
920
410
.03
40
1050
465
.04
43
1425
635
.06
41
1630
725
.07
44
DCD-86
3/2006
3/2006
ALL
SUPPLIES
30" x 30"
SUPPLY
Ak = 1.30
21" x 21"
RETURN
Ak = 3.06
33" x 33"
SUPPLY
Ak = 1.80
21" x 21"
RETURN
Ak = 3.06
36" x 36"
SUPPLY
Ak = 2.00
24" x 24"
RETURN
Ak = 4.00
39" x 39"
SUPPLY
Ak = 2.20
27" x 27"
RETURN
Ak = 5.06
42" x 42"
SUPPLY
Ak = 2.90
27" x 27"
RETURN
Ak = 5.06
42" x 42"
SUPPLY
Ak = 2.40
30" x 30"
RETURN
Ak = 6.25
42" x 42"
SUPPLY
Ak = 1.87
33" x 33"
RETURN
Ak = 7.56
200
300
640
3-7
955
5-12
FACE VELOCITY
Ps
Pt
500
.013
.016
TOTAL CFM
INLET VELOCITY
Ps
NC
480
155
.01
-
TOTAL CFM
THROW
NECK VELOCITY
400
500
750
.03
.04
1000
.05
.06
1250
.08
.10
715
235
.01
20
955
310
.01
27
1195
390
.02
33
1275
7-16
1595
9-17
600
700
800
1500
.12
.14
1750
.16
.19
2000
.21
.25
ALL
SUPPLIES
1435
470
.03
38
1675
545
.04
42
1910
625
.05
45
33" x 33"
RETURN
Ak = 7.56
TOTAL CFM
THROW
900
4-8
1350
6-13
1800
8-17
TOTAL CFM
INLET VELOCITY
Ps
NC
675
220
.01
-
1010
330
.02
20
1350
440
.03
28
1690
550
.04
34
TOTAL CFM
THROW
1000
4-8
1500
5-13
2000
8-18
TOTAL CFM
INLET VELOCITY
Ps
NC
750
185
.01
-
1125
280
.01
20
1500
375
.02
28
1875
470
.03
34
TOTAL CFM
THROW
1100
5-10
1650
8-17
TOTAL CFM
INLET VELOCITY
Ps
NC
825
165
.01
-
1240
245
.01
20
1650
325
.015
29
TOTAL CFM
THROW
1440
4-10
TOTAL CFM
INLET VELOCITY
Ps
NC
1080
215
.01
-
1615
320
.01
23
2160
425
.03
30
TOTAL CFM
THROW
1200
4-10
1800
8-17
TOTAL CFM
INLET VELOCITY
Ps
NC
900
145
.01
-
1350
215
.01
-
1800
290
.01
25
2250
360
.02
33
TOTAL CFM
THROW
940
4-9
1410
6-13
1880
8-18
TOTAL CFM
INLET VELOCITY
Ps
NC
705
95
.002
-
1055
140
.003
20
1410
185
.005
25
1760
230
.009
33
2060
410
.02
35
2695
530
.04
36
2025
660
.06
39
2250
560
.05
39
2475
490
.03
40
3235
640
.06
41
2700
430
.03
35
2110
280
.013
35
2360
770
.08
43
2625
655
.06
43
2890
570
.05
44
3775
745
.08
45
3150
505
.04
40
2460
325
.017
40
2700
880
.11
46
3000
750
.08
47
45" x 45"
SUPPLY
Ak = 2.60
48" x 48"
SUPPLY
Ak = 3.37
33" x 33"
RETURN
Ak = 7.56
60" x 60"
SUPPLY
Ak = 4.37
45" x 45"
RETURN
Ak = 14.06
NECK VELOCITY
200
300
TOTAL CFM
THROW
1300
5-10
1950
9-20
TOTAL CFM
THROW
1690
6-11
TOTAL CFM
THROW
2190
7-13
FACE VELOCITY
Ps
Pt
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
INLET VELOCITY
Ps
NC
500
.013
.016
975
130
.003
-
1265
170
.01
-
1640
115
.002
-
750
.03
.04
400
500
600
700
800
1000
.05
.06
1250
.08
.10
1500
.12
.14
1750
.16
.19
2000
.21
.25
1950
255
.01
28
2440
320
.015
33
2925
390
.02
39
3410
450
.03
44
3900
515
.04
48
1900
250
.01
23
2530
335
.02
32
3165
420
.03
37
3800
500
.04
41
4430
585
.05
45
5065
670
.06
49
2460
175
.004
28
3280
235
.007
32
4100
290
.01
35
4925
350
.02
38
5745
410
.025
41
6565
465
.03
46
1460
195
.006
22
DCD
Air Pattern
Diagram
3300
650
.06
47
4310
850
.10
48
3600
575
.05
45
2815
370
.022
45
DCD-87
3/2006
ALL
SUPPLIES
36" x 24"
SUPPLY
Ak = 1.28
27" x 15"
RETURN
Ak = 2.80
DCD
36" x 27"
SUPPLY
Ak = 1.35
27" x 18"
RETURN
Ak = 3.37
36" x 30"
SUPPLY
Ak = 1.43
27" x 21"
RETURN
Ak = 3.93
42" x 33"
SUPPLY
Ak = 2.10
30" x 21"
RETURN
Ak = 4.37
48" x 21"
SUPPLY
Ak = 1.50
39" x 12"
RETURN
Ak = 3.25
48" x 24"
SUPPLY
Ak = 1.57
39" x 15"
RETURN
Ak = 4.06
48" x 27"
SUPPLY
Ak = 1.65
39" x 18"
RETURN
Ak = 4.87
FACE VELOCITY
Ps
Pt
TOTAL CFM
THROW A SIDE
THROW B SIDE
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
200
500
.013
.016
640
5-7
4-7
480
170
.01
20
675
5-8
4-7
505
150
.01
20
720
255
.01
23
1015
7-10
6-9
1280
9-13
7-11
1250
.08
.10
1600
11-17
9-14
600
1500
.12
.14
700
1750
.16
.19
800
2000
.21
.25
960
340
.02
26
1350
9-13
8-12
1070
270
.01
26
2100
11-16
9-14
790
180
.01
20
750
4-8
3-6
1180
270
.01
23
1125
7-11
6-9
885
220
.01
23
1240
8-12
7-10
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
560
170
.01
20
790
5-8
4-7
TOTAL CFM
INLET VELOCITY
Ps
NC
960
7-10
5-9
1000
.05
.06
500
715
5-9
4-7
535
135
.01
20
1050
6-10
4-8
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
750
.03
.04
400
Air Pattern
Diagram
760
225
.01
23
1070
7-11
6-9
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
300
NECK VELOCITY
590
145
.01
20
825
6-8
5-7
620
130
.01
20
800
205
.01
23
1575
8-12
6-10
845
260
.01
23
1180
7-11
6-9
930
190
.01
23
1010
300
.01
26
1430
9-13
8-12
1240
255
.01
26
1550
320
.01
30
1860
380
.02
35
2170
445
.03
40
2480
510
.04
45
DCD-88
3/2006
48 x 30
SUPPLY
Ak = 1.73
FACE VELOCITY
Ps
Pt
TOTAL CFM
THROW A SIDE
THROW B SIDE
500
.013
.016
TOTAL CFM
THROW A SIDE
THROW B SIDE
1250
7-11
5-9
TOTAL CFM
THROW A SIDE
THROW B SIDE
1625
8-13
7-12
36 x 37
RETURN
Ak = 6.75
TOTAL CFM
INLET VELOCITY
Ps
NC
33 x 30
RETURN
Ak = 6.87
TOTAL CFM
INLET VELOCITY
Ps
NC
48 x 45
SUPPLY
Ak = 3.25
2000
.21
.25
1725
330
.015
26
1200
7-11
5-9
48 x 39
SUPPLY
Ak = 2.50
1750
.16
.19
800
1295
250
.01
23
TOTAL CFM
THROW A SIDE
THROW B SIDE
TOTAL CFM
INLET VELOCITY
Ps
NC
1500
.12
.14
700
860
165
.01
20
48 x 36
SUPPLY
Ak = 2.40
36 x 24
RETURN
Ak = 6.00
1250
.08
.10
600
48 x 33
SUPPLY
Ak = 2.30
TOTAL CFM
INLET VELOCITY
Ps
NC
1000
.05
.06
500
1295
7-11
6-9
650
115
.01
20
1150
7-11
5-8
36 x 21
RETURN
Ak = 5.25
750
.03
.04
400
865
5-9
4-7
TOTAL CFM
INLET VELOCITY
Ps
NC
TOTAL CFM
THROW A SIDE
THROW B SIDE
39 x 21
RETURN
Ak = 5.68
300
Air Pattern
Diagram
900
150
.01
20
940
140
.01
20
1220
180
.01
20
970
170
.01
23
1725
9-13
6-10
1295
230
.01
26
2300
11-17
9-14
2155
410
.02
30
2590
495
.03
35
3020
575
.05
40
3450
655
.06
45
1800
300
.01
26
2250
375
.02
30
2700
450
.03
35
3150
525
.04
40
3600
600
.05
45
1875
280
.01
26
2345
350
.02
30
2810
415
.025
35
3280
485
.03
40
3750
555
.04
45
2440
355
.02
26
3050
445
.03
30
3660
535
.04
35
4270
620
.05
40
4875
710
.07
45
1875
9-13
7-11
1405
210
.01
23
1800
9-13
7-11
1350
225
.01
23
DCD
ALL
SUPPLIES
200
NECK VELOCITY
DCD-89
3/2006
ALL
SUPPLIES
60" x 21"
SUPPLY
Ak = 1.82
1750
.16
.19
800
2000
.21
.25
TOTAL CFM
THROW A SIDE
THROW B SIDE
975
7-11
4-7
1465
9-13
6-9
1950
11-17
8-12
TOTAL CFM
THROW A SIDE
THROW B SIDE
1015
7-11
4-7
1520
9-13
6-9
2030
11-17
8-12
TOTAL CFM
THROW A SIDE
THROW B SIDE
1350
8-13
5-9
TOTAL CFM
THROW A SIDE
THROW B SIDE
1400
8-13
5-9
1450
8-13
5-9
1810
9-15
7-11
2720
11-17
9-13
TOTAL CFM
INLET VELOCITY
Ps
NC
48" x 21"
RETURN
Ak = 7.00
TOTAL CFM
INLET VELOCITY
Ps
NC
48" x 24"
RETURN
Ak = 8.00
TOTAL CFM
INLET VELOCITY
Ps
NC
48" x 27"
RETURN
Ak = 9.00
TOTAL CFM
INLET VELOCITY
Ps
NC
45" x 27"
RETURN
Ak = 8.43
TOTAL CFM
INLET VELOCITY
Ps
NC
60" x 42"
SUPPLY
Ak = 3.62
1500
.12
.14
700
51" x 21"
RETURN
Ak = 7.43
60" x 39"
SUPPLY
Ak = 2.90
1250
.08
.10
600
1820
11-17
8-11
TOTAL CFM
INLET VELOCITY
Ps
NC
60" x 36"
SUPPLY
Ak = 2.80
1000
.05
.06
500
1365
9-13
6-9
51" x 18"
RETURN
Ak = 6.37
60" x 33"
SUPPLY
Ak = 2.70
750
.03
.04
400
910
6-10
4-7
TOTAL CFM
INLET VELOCITY
Ps
NC
60" x 30"
SUPPLY
Ak = 2.02
500
.013
.016
300
Air Pattern
Diagram
TOTAL CFM
THROW A SIDE
THROW B SIDE
51" x 12"
RETURN
Ak = 4.25
60" x 27"
SUPPLY
Ak = 1.95
DCD
FACE VELOCITY
Ps
Pt
200
NECK VELOCITY
TOTAL CFM
THROW A SIDE
THROW B SIDE
TOTAL CFM
THROW A SIDE
THROW B SIDE
680
160
.01
20
730
115
.01
20
760
100
.01
20
1010
145
.01
20
1050
130
.01
20
1090
120
.01
20
1360
160
.01
20
1025
240
.01
23
1110
175
.01
23
1140
155
.01
23
1365
320
.01
26
1460
230
.01
26
1520
205
.01
26
1705
400
.02
30
2050
480
.03
35
2390
560
.05
40
2730
640
.06
45
1833
290
.01
30
2200
345
.02
35
2560
400
.03
40
2925
460
.04
45
1900
255
.01
30
2280
310
.02
35
2660
360
.03
40
3040
410
.04
45
1520
215
.01
23
2025
290
.01
26
2530
360
.02
30
3035
435
.03
35
3545
505
.04
40
4050
580
.05
45
1575
195
.01
23
2100
260
.01
26
2625
330
.02
30
3150
395
.03
35
3675
460
.04
40
4200
525
.05
45
1630
180
.01
23
2175
240
.01
26
2720
300
.02
30
3260
360
.025
35
3805
420
.03
40
4350
485
.04
45
2720
320
.01
30
3400
405
.02
35
4080
485
.03
40
4755
565
.04
45
5440
645
.06
50
2040
240
.01
25
DCD-90
3/2006
60 x 45
SUPPLY
Ak = 3.75
FACE VELOCITY
Ps
Pt
1500
.12
.14
700
1750
.16
.19
800
2000
.21
.25
TOTAL CFM
THROW A SIDE
THROW B SIDE
1940
9-15
7-12
2910
11-17
9-14
2000
9-15
8-13
TOTAL CFM
INLET VELOCITY
Ps
NC
45 x 36
RETURN
Ak = 11.25
TOTAL CFM
INLET VELOCITY
Ps
NC
42 x 36
RETURN
Ak = 10.50
TOTAL CFM
INLET VELOCITY
Ps
NC
42 x 39
RETURN
Ak = 11.37
TOTAL CFM
INLET VELOCITY
Ps
NC
60 x 57
SUPPLY
Ak = 4.95
1250
.08
.10
600
2815
11-17
9-14
45 x 33
RETURN
Ak = 10.30
60 x 54
SUPPLY
Ak = 4.80
1000
.05
.06
500
1875
9-15
7-12
TOTAL CFM
INLET VELOCITY
Ps
NC
60 x 51
SUPPLY
Ak = 4.00
750
.03
.04
400
TOTAL CFM
THROW A SIDE
THROW B SIDE
45 x 30
RETURN
Ak = 9.37
60 x 48
SUPPLY
Ak = 3.88
500
.013
.016
300
Air Pattern
Diagram
TOTAL CFM
THROW A SIDE
THROW B SIDE
1400
150
.01
20
2810
300
.01
30
3520
375
.02
35
4220
450
.03
40
4925
525
.04
45
5625
600
.05
50
2910
280
.01
30
3640
355
.02
35
4365
425
.025
40
5090
495
.03
45
5820
565
.04
50
2250
200
.01
25
3000
265
.01
30
3750
335
.02
35
4500
400
.025
40
5250
465
.03
45
6000
535
.04
50
1800
170
.01
20
2700
255
.01
25
3600
340
.02
30
4500
430
.03
35
5400
515
.04
40
6300
600
.05
45
7200
685
.07
50
1860
165
.01
20
2790
245
.01
25
3710
325
.01
30
4640
410
.02
35
5570
490
.03
40
6500
570
.05
45
7425
655
.06
50
1455
140
.01
20
1500
135
.01
20
2110
225
.01
25
2180
210
.01
25
TOTAL CFM
THROW A SIDE
THROW B SIDE
TOTAL CFM
THROW A SIDE
THROW B SIDE
DCD
ALL
SUPPLIES
200
NECK VELOCITY
DCD-91
3/2006
DCD
Surface Mount
V-Beveled Drop Face
Deep Drop Frame
T-bar Lay-in
Concealed Spline
Tegular Lay-in
Combination concentric supply/return units shall be model 5500 DAF-CC5 manufactured by METALAIRE. Units shall consist of a fixed pattern outer ring of
louvers that discharge supply air. The inner return or exhaust core shall consist of aluminum 1/2" x 1/2" x 1/2" cubed core.
Units shall be designed to integrate into the specified ceiling system.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
DCD-92
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Supply
Return
Available Finishes
12" x 12"
thru
60" x 60"
9" x 9"
thru
45" x 45"
Standard
01 - White
Optional
03 - Black
24 - Mill
28 - Custom Color
Supply
Return
Module
12" x 12"
thru
42" x 42"
9" x 9"
thru
33" x 33"
24" x 24"
48" x 24"
48" x 48"
Standard
Available Finishes
01 - White
DCD
Model
Optional
03 - Black
24 - Mill
28 - Custom Color
DCD-93
3/2006
1
e+12
me
1
4
1
22
DCD
7)
Product Details
1
Opening
= Listed Size
+12
The 9000 is Ceiling
a highly
flexible
directional
mounting
Duct Size = Listed Size
1
applications
ceiling
in a
Spring
Loaded
= Listed Size available
-4
Neck Size diffuser
Core Latch
(2 Per Core)
wide
range of border types
Low Limit
Low Limit
Frame
1
22
Spring Loaded
Core Latch
(2 Per Core)
Low Limit
of Duct 1 3
4
Ceiling Line
1
4
mit
13
4
1
4
1
-4
g Line
1
22
1
Overall Diffuser = T-Bar Spacing - 4
Low Limit
of Duct 1 3
4
Ceiling Line
1
4
Ceiling Line
1
Ceiling Opening = Listed Size + 4
Duct Opening = Listed Size
1
Neck Size = Listed Size - 4
Spring Loaded
Core Latch
(2 Per Core)
Kerf (2)
Low Limit
of Duct 2
ler Panel
1
ng - 16
DCD-94
Low Limit
of Duct 2
Remova
23
4
Ceiling Line
Frame
Low Limit
of Duct 2
Lay-In
Filler Panel
23
4
Ceiling Line
Ov
1
Overall Diffuser = T-Bar Spacing - 4
Ceiling Line
Frame
Removable Mod
3
4
Ceiling Line
1
Overall Diffuser = T-Bar Spacing - 4
Spring
Co
(2 P
1
Overall Diffuser = T-Bar Spacing - 4
Frame
1
4 Turn Latch Locks
Low Limit 2 3
4
of Duct = 2
Duct
On Concealed T-Bar
23
4
Side Splines (2) Optional
Ceil
Spring Loaded
Core Latch
(2 Per Core)
1
Overall Diffuser = T-Bar Spacing - 4
Removable Modular Core
Frame
Duct Opening
= Listed Size
1
NeckSize
Size +
= Listed
Overall
= Listed
4 21 Size - 4
Spring
Loaded
ze
1
4
Ceiling Line
1
Neck Size = Listed Size - 4
3
4
Frame
Core Latch
(2 Per Core)
Low Limit 2 3
4
of Duct = 2
1
Overall Diffuser = T-Bar Spacing - 4
Spring
Loaded
Core Latch
(2 Per Core)
Ceiling Line
1
22
Ceiling Line
Removable
Modular Core
Frame
Square/Rectangular
Modular
Core Ceiling
Diffusers
T-bar Lay-in
Model 9000-6
3
4
Frame
1
22
Spring Loaded
Core Latch
(2 Per Core)
1
Neck Size = Listed Size - 4
Low Limit 2 3
4
of Duct = 2
1
Ceiling Opening = Listed Size + 1 2
Spring Loaded
Core Latch
(2 Per Core)
Remov
1
Ceiling Opening = Listed Size + 4
Duct Opening = Listed Size
1
Neck Size = Listed Size - 4
1
Ceiling Opening = Listed Size + 4
Duct Opening = Listed Size
1
Neck Size = Listed Size - 4
Spring Loaded
Core Latch
(2 Per Core)
Ceiling Line
1
1Lay-in
Spring
can be
in surface
Loaded T-bar border
= Listed
Sizeused
-4
Neck Size 6
4
Core Latch
applications by adding optional
(2 mounting
Per Core)
Ceiling Line
T-bar Plaster Frame (TBPF)
1
4
Overall
Listed Size +5
(127) spring loaded
Cores are easy
to= remove
with
1
latches - noCeiling
toolsOpening
required
= Listed Size + 1 2
1
22
of Duct 1 3
4
Spring Loaded
Core Latch
(2 Per Core)
Ceiling Line
1
Overall Diffuser = T-Bar Spacing - 16
Low Limit
of Duct 2
Spring Loaded
Core Latch
(2 Per Core)
23
4
Duct Opening
= Listed=Size
T-Bar Spacing
24 x 24
1
1
Neck
Size
= Listed
Size Spacing
-4
Overall
Diffuser
= T-Bar
-4
Spring
Loade
Core Latch
Frame
Lay-In
Filler Panel
Low Limit
of Duct 2
Ceiling Line
Removable
Filed
Adjustable
DeflectionModular
PatternsCore
Lay-In Filler
Panel
Frame Air
22 8 x 22 8 Overall Face
23
4
Low Limit
of Duct 2
23
4
Spring Loaded
Core Latch
Spr
(2 Per Core)
Loa
Core La
Removable Modul
Lay
Obtaine
T-Bar Spacing = 24 x 24
A
B
B
DCD
23
4
Spring
Loaded
Core Latch
3/2006
Three Way
Four Way
A
B
B
A
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
28 Custom color
2. Available Accessories
(Shipped Unattached)
OBD - Opposed Blade Damper - Steel . . . . . . . . . . . . .334
OBDA - Opposed Blade Damper - Aluminum . . . . . . .334
L9 - Equalizing Grid . . . . . . . . . . . . . . . . . . . . . . . . . .334
TR Deep - Square to Round Transition - Deep . . . . . .338
A
B
B
A
A
B
B
A
A
B
B
A
DCD-95
DCD
8" x 8"
0.44
10" x 10"
0.69
12" x 12"
1.00
14" x 14"
1.36
16" x 16"
1.78
18" x 18"
2.25
20" x 20"
2.78
22" x 22"
3.36
24" x 24"
4.00
0.112
0.196
0.312
0.444
0.604
0.792
0.996
1.236
1.492
1.776
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
4-Way
3-Way
2-Way
1-Way
4-Way
3-Way
2-Way
1-Way
200
450
0.013
A
B
300
675
0.028
A
B
400
900
0.050
A
B
500
1125
0.079
A
B
600
1350
0.114
A
B
2-3
2-3 3-4
3-4
4-6
90
<20
3-4
3-4 4-6
4-6
6-8
130
<20
4-5
4-5 6-7
6-7
8-10
175
<20
4-6
4-6 6-8
6-8
8-12
220
23
5-7
6-8
5-7 7-10 6-8 8-11
7-10
8-11
10-14
12-16
265
310
28
33
3-4
4-5
5-7
50
<20
4-Way
3-Way
2-Way
1-Way
4-5
4-Way
3-Way
2-Way
1-Way
4-6
4-Way
3-Way
2-Way
1-Way
5-7
4-Way
3-Way
2-Way
1-Way
5-8
4-Way
3-Way
2-Way
1-Way
6-9
4-Way
3-Way
2-Way
1-Way
4-Way
3-Way
2-Way
1-Way
4-Way
3-Way
2-Way
1-Way
3-4
4-6
4-6
6-8
140
<20
4-5
6-7
6-7
8-10
200
<20
4-6
6-8
6-8
8-12
270
<20
75
<20
4-5
6-7
6-7
8-10
205
<20
100
<20
125
20
150
26
700
1575
0.155
A
B
175
31
Air Pattern
Diagram
A
B
B
5-7
6-8
6-9
7-10
7-10 6-8 8-11 6-9 8-13 7-10 10-14
7-10
8-11
8-13
10-14
10-14
12-16
12-18
14-20
275
345
415
485
<20
23
28
33
5-7
6-9
7-10
8-12
9-13
7-10 6-9 8-13 7-10 10-14 8-12 11-17 9-13 13-18
7-10
8-13
10-14
11-17
13-18
10-14
12-18
14-20
16-24
18-26
300
400
500
600
700
<20
<20
25
31
36
5-7
6-8
7-10
8-12
9-14
10-15
8-11 7-10 10-14 8-12 11-17 9-14 13-20 10-1514-21
8-11
10-14
11-17
13-20
14-21
12-16
14-20
16-24
18-28
20-30
405
545
680
815
950
<20
21
27
33
38
6-8
5-7
7-10
8-12
10-14
11-17
12-18
7-10 7-10 10-14 8-12 11-17 10-1414-20 11-17 16-24 12-1817-25
7-10
10-14
11-17
14-20
16-24
17-25
10-14
14-20
16-24
20-28
22-34
24-36
355
530
710
885
1070
1245
20
20
21
28
33
38
5-8
8-11
9-14
11-16
12-19
13-20
7-11 8-11 11-16 9-14 13-20 11-16 16-22 12-1917-27 13-2018-28
7-11
11-16
13-20
16-22
17-27
18-28
10-16
16-22
18-28
22-32
24-38
26-40
450
670
900
1120
1345
1570
<20
<20
22
29
34
39
12-18
6-9
9-12
10-15
13-21
15-23
8-13 9-12 13-17 10-1514-21 12-1817-25 13-2118-30 15-2321-32
17-25
8-13
13-17
14-21
18-30
21-32
24-36
12-18
18-24
20-30
26-42
30-46
555
830
1110
1390
1670
1945
<20
<20
23
30
35
40
7-10
10-13
12-16
13-20
15-23
16-24
7-10 10-14 10-1314-18 12-1617-22 13-2018-28 15-2321-32 16-2422-34
10-14
14-18
17-22
18-28
21-32
22-34
14-20
20-26
24-32
26-40
30-46
32-48
670
1010
1345
1680
2015
2350
<20
<20
23
31
36
41
7-11
11-15
13-18
15-22
16-25
18-27
7-11 10-16 11-15 16-21 13-1818-25 15-2221-31 16-2522-35 18-2725-38
10-16
16-21
18-25
21-31
22-35
25-38
14-22
22-30
26-36
30-44
32-50
36-54
800
1200
1600
2000
2400
2800
<20
<20
26
32
38
42
8-12
12-16
14-20
16-24
18-28
20-30
8-12 11-17 16-1617-22 14-2020-28 16-2422-34 18-2825-39 20-3028-42
11-17
17-22
20-28
22-34
25-39
28-42
16-24
24-32
28-40
32-48
36-56
40-60
DCD-96
3/2006
3/2006
Ak
Neck
Effective
Outlet Vel
Area
Pt.
(Sq. Ft.)
3" X 3"
0.063
0.028
4" X 4"
0.111
0.049
5" X 5"
0.174
0.078
6" X 6"
0.250
0.111
7" X 7"
0.340
0.151
8" X 8"
0.445
0.198
9" X 9"
0.562
0.249
10" X 10"
0.695
0.309
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
200
450
0.013
300
675
0.028
400
900
0.50
500
1125
0.079
600
1350
0.114
700
1575
0.155
800
1800
0.202
22
3-4
<20
33
4-5
<20
44
5-7
<20
56
6-8
<20
67
6-9
22
78
7-10
27
89
8-11
31
13
2-3
<20
35
4-5
<20
50
4-6
<20
19
3-4
<20
52
5-7
<20
136
8-12
<20
170
10-14
21
204
11-17
27
225
10-15
<20
281
12-18
23
178
9-14
<20
169
9-12
<20
208
10-13
<20
38
5-7
20
104
8-12
22
133
8-11
<20
112
6-9
<20
32
4-6
<20
87
7-10
<20
100
7-10
<20
102
7-10
<20
139
7-10
<20
70
6-9
<20
75
6-8
<20
68
5-7
<20
89
5-8
<20
25
4-5
<20
278
12-16
<20
125
8-12
<20
44
6-8
25
122
9-13
27
139
10-14
31
238
12-18
32
272
13-19
35
393
15-23
33
459
16-24
37
150
9-14
25
175
10-15
30
222
11-16
22
267
12-19
27
311
13-20
32
347
13-20
24
416
15-23
29
486
16-24
34
337
13-21
28
50
6-9
27
200
11-16
34
DCD
Single
Core Size
(Inches)
Single Core - Models 9000-1, 9000-2, 9000-6, 9000-6P, 9000-7, 9000-8, 9000-9
355
15-22
36
555
18-26
38
Surface Mounted
Beveled
T-bar Lay-in
Concealed Spline
Tegular Lay-in
Donn Fineline Lay-in
Air Outlets shall be model 9000 manufactured by METALAIRE. Units shall consist of an adjustable set of modular core pattern controllers that are
removable from the face of the outlet without the use of tools. Outlets shall be extruded aluminum construction. Steel border or cores are not acceptable.
The units shall be the size and quantity as outline in the plans and specifications.
Outlets shall field adjustable to obtain 1, 2-way opposite, 2-way corner, 3, and 4-way directional air patterns.
Units shall be designed to integrate into the specified ceiling system.
DCD-97
3/2006
Optional Dampers
Aluminum opposed blade dampers shall be provided. Damper shall be adjusted using a handle accessible through the face of the diffuser.
Screwdriver slot operators are not allowed.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
DCD
Accessories
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
Available Neck
6"
Air Pattern
Available Finishes
Standard
Standard
Available Options
OBD
OBDA
L9
Equalizing Grid
TR Deep
S4 - 4 Core
01 - White
Model
9000-6 - T-bar Lay-in
9000-7 - Concealed Spline
Available Neck
Optional
S1 - 1-way
02 - Aluminum
S2 - 2-way
03 - Black
S3 - 3-way
28 - Custom Color
Module
thru
18" x 18"
Optional
Air Pattern
Available Finishes
Standard
Standard
S4 - 4 Core
01 - White
Available Options
OBD
OBDA
L9
Equalizing Grid
TR Deep
24" x 24"
Optional
02 - Aluminum
03 - Black
28 - Custom Color
DCD-98
P
P
C
C
D
D
PERFORATED
PERFORATED
CEILING DIFFUSERS
CEILING DIFFUSERS
3/2006
Perforated Supply - Extruded Aluminum - Curved Blade Pattern Controller - Series 7000
Model 7000
Pg. 104
The series 7000 is an aluminum, perforated supply diffuser with curved blade pattern controllers mounted in
the neck of the diffuser. Pattern controllers are adjustable from a horizontal to vertical discharge pattern
The face is secured with spring clips making removal and access to the pattern controllers easy
Units are available in 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way patterns
The Series 7000 generates a star pattern directional discharge of air maximizing induction and room
air mixing
T-bar Lay-in border type 6 is designed to be installed in standard 15/16 tee. This border type 6 can be
used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Matching returns available: 7000R
The series 7000 is an excellent choice for VAV applications
Supply
Return
PCD
The series PRTB is an economical choice for non-duct plenum return applications and is shipped without
pattern controllers
Unit can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Aluminum
Model PRTB
Steel
Model 7300
Pg. 114
The series 7300 perforated supply diffuser is an economical diffuser with a fiberglass plenum designed to
allow field installation of the inlet collar (by others). The face of the diffuser is non-removable and includes a
pattern controller set for a circular 360 degree round discharge pattern
The series 7300 provides a 360 tight horizontal circular pattern along the ceiling
The series 7300 includes a T-bar Lay-in border type 6 which is designed to be installed in standard
15/16 tee
Border type 6 can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Matching returns available: 7300R
The series 7300 is an excellent choice for VAV applications
T-bar Lay-in
Model 7350
Pg. 116
The series 7350 perforated supply diffuser is an economical diffuser with a fiberglass plenum designed to
allow field installation of the inlet collar (by others)
The face diffuser includes a hinged removable face and 4 pattern controllers that can adjusted for a 1-way,
2-way opposite, 2-way corner, 3-way, and 4-way discharge air patterns
Set in a 4-way pattern, the 7350 provides a 360 tight horizontal circular pattern along the ceiling
The series 7350 includes a T-bar Lay-in border type 6 designed to be installed in standard 15/16 tee
Border type 6 can be used in surface mounting applications by adding optional T-bar Plaster Frame (TBPF)
Matching returns available: 7350R
The series 7350 is an excellent choice for VAV applications
Supply
PCD-100
Return
T-bar Lay-in
7350-6 Hinged Steel Removable Face 7350R-6 Hinged Steel Removable Face
7350-6 AF Hinged Aluminum
7350R-6 AF Hinged Aluminum
Removable Face
Removable Face
Tegular T-bar
3/2006
Model 7500
Pg. 118
Round Neck
Series 7500 - Supply
Series 7500R - Return
The series 7500 and 7550 perforated supply diffusers have 4 adjustable pattern controllers mounted
on the face of the diffuser. Pattern controllers are adjustable from a horizontal to vertical discharge pattern
Series 7500 are round neck diffusers; series 7550 are square neck diffusers
The hinged, fully removable face allow access to the pattern controllers
Unit can be adjusted for 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way patterns
In 4-way pattern, Series 7500 provides a 360 tight horizontal circular pattern along the ceiling
T-bar Lay-in border type 6 is designed to be installed in standard 15/16 tee
Border type 6 can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Matching returns available: 7500R (round neck) and 7550R (square neck)
The series 7500 and 7550 are excellent choices for VAV applications
Square Neck
Series 7550 - Supply
Series 7550R - Return
Round Neck
Supply
7500-1 Surface Mount
7500-1 DF Surface Mount - Drop Face
7500-1 AF Surface Mount - Aluminum Face
7500-6 T-bar Lay-in
7500-6 AF T-bar Lay-in - Aluminum Face
7500-6 AL T-bar Lay-in - All Aluminum
Return
PCD
Perforated Ceiling Diffuser - Face Mounted Adjustable Pattern Controller - Series 7500
Square Neck
Supply
7550-1 Surface Mount
7550-1 DF Surface Mount - Drop Face
7550-1 AF Surface Mount - Aluminum Face
7550-6 T-bar Lay-in
7550-6 AF T-bar Lay-in - Aluminum Face
7550-6 AL T-bar Lay-in - All Aluminum
Return
Perforated Ceiling Diffuser - Curved Blade - Neck Mounted Pattern Controller - Series 7600
Model 7600
Pg. 134
Round Neck
Series 7600 - Supply
Series 7600R - Return
Square Neck
Series 7650 - Supply
Series 7650R - Return
The Series 7600 and 7650 perforated supply diffusers have curved blade pattern controllers mounted
in the neck of the diffuser. Pattern controllers are adjustable from a horizontal to vertical discharge pattern
Series 7600 are round neck diffusers; series 7650 are square neck diffusers
The hinged, fully removable face allow access to the pattern controllers
Units are available in 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way patterns. The 4-way core can
be set for corner or side discharge patterns. The series 7600 and 7650 provide a star pattern directional
discharge of air maximizing induction and room air mixing
T-bar Lay-in border type 6 is designed to be installed in standard 15/16 tee
Border type 6 can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Matching returns available: 7600R (round neck) and 7650R (square neck)
The series 7600 and 7650 are excellent choices for VAV applications
Round Neck
Supply
Return
Square Neck
Supply
7650-1 Surface Mount
7650-1 DF Surface Mount - Drop Face
7650-1 AF Surface Mount - Aluminum Face
7650-6 T-bar Lay-in
7650-6 AF T-bar Lay-in - Aluminum Face
7650-6 AL T-bar Lay-in - All Aluminum
Return
PCD-101
3/2006
Model 7900
Pg. 150
The series 7900 is an aluminum, perforated modular core supply diffuser. Modular cores can be field
adjusted for 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way air discharge patterns
The perforated face is secured with spring clips making removal and access to the modular core
pattern controllers easy
T-bar Lay-in border type 6 is designed to be installed in standard 15/16 tee
Border type 6 can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Matching returns available: 7900R
The series 7900 is an excellent choice for VAV applications
Supply
7900-1
7900-6
7900-7
7900-8
Surface Mount
T-bar Lay-in
Concealed Spline
Tegular T-bar
PCD
Perforated Face Modular Core Diffuser - Aluminum Deflectors/Steel Backpan - Square Neck - Series 7950
Model 7950
Pg. 156
The series 7950 perforated modular core supply diffuser with a steel backpan. Modular cores can be field
adjusted for 1-way, 2-way opposite, 2-way corner, 3-way, and 4-way air discharge patterns
The perforated face is secured with spring clips making removal and access to the modular core
pattern controllers easy
T-bar Lay-in border type 6 is designed to be installed in standard 15/16 tee
Border type 6 can be used in surface mounting applications by adding optional T-bar plaster frame (TBPF)
Matching returns available: 7950R
The 7950 is an excellent choice for VAV applications
Supply
7950-1 Surface Mount
7950-8 Tegular T-bar
7950-1 DF Surface Mount - Drop Face
7950-8 AF Tegular T-bar - Aluminum Face
7950-1 AF Surface Mount - Aluminum Face 7950-9 Donn Fineline
7950-6 T-bar Lay-in
7950-6 AF T-bar Lay-in - Aluminum Face
Model
7550R-F
Pg. 160
PCD-102
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
Removable Curved
Blade Air Pattern Core
1
8
5
8
Perforated Face
Retaining Spring (4 Per Unit)
1
Nominal Neck Size 8
.900
Perforated Face
Retaining Spring
(4 Per Unit)
1
2 4*
21**
8
9
16
Perforated Face
Gasket
1
16
Product Details
The series 7000 is an aluminum, perforated
supply diffuser with curved blade pattern
controllers mounted in the neck of the diffuser.
Pattern controllers are adjustable from a
horizontal to vertical discharge pattern
1
16
1 1
4
3/2006
5
32
1
2
3
8
3
4
Face Plate
Retaining Spring
Units
are available in 1-way,8 2-way opposite,
Auxiliary
Panel
2-way corner, 3-way, and 4-way patterns 1
TheAirSeries
star pattern
Pattern Core 7000 generates a Perforated
Face Plate
Retaining Spring
Adjustable Curved Blade
directional
discharge
of air
maximizing induction
Air Pattern
Controller
Removable
Air
Pattern Core
1
and room air
mixing
Overall
Diffuser = T-Bar Module - 4
PCD
1
8
Perforated Face
Retaining Spring
(4 Per Unit)
Mounting
Spring
1
2 4*
Air Pattern Core
Retaining Spring
9
16
T-Bar Module
Removable Curved
Blade Air Pattern Core
3
4
Perforated Face
Overall Diffuser = Nominal Ceiling Grid Size * Dimension indicates distance to bottom of duct
which should be maintained as closely as possible.
1
16
Model 7000-6
Supply
Supply - Perforated Ceiling Diffuser - Surface Mount
Model 7000-1
1
Neck Size = Listed size - 8
1
24
5
8
Perforated Face
Retaining Spring (4 Per Unit)
1
Nominal Neck Size 8
.900
5
8
Perforated Face
Retaining Spring (4 Per Unit)
Perforated
Face
1
Retaining Spring
Nominal Neck Size 8
22 7.900
x 22 7 Overall Face
21**
8
Gasket
8
8
Overall Diffuser = 23
3
3
4 x 23 4
T-Bar Module = 24 x 24
21**
8
Gasket
Mounting
Spring
9
16
1
Adjustable
Neck SizeCurved
= ListedBlade
Size 8
Air Pattern Controller
3
3
Overall Diffuser = 23 4 x 23 4
T-Bar Module = 24 x 24
Perforated Face
3
Optional
Retaining Spring
8
Drop Face
(4 Per Unit)
1
2 4*
Perforated Face
Overall Diffuser = Nominal Ceiling Grid Size * Dimension indicates distance to bottom of duct
which should be maintained as closely as possible.
PCD-104
14
Removable Air
1
16
Removable Curved
Blade Air Pattern Core
3
4
Auxiliary
Panel
Removable Curved
Pattern Core
Blade Air Pattern Core
5
32
Face Plate
Retaining Spring
1 34
1
4
2-Concealed
Spring Latches
1
16
Removable Air
Pattern Core
3
8
3
4
1
16
5
32
1
2
1 1
4
Mounting
Spring
9
1
2 416
1
8
Perforated Face
Retaining Spring
(4 Per Unit)
1
Neck Size = Listed size - 8
1
2 4*
Face Plate
Retaining
Spring
Perforated Face
1
16
Removable Air
Pattern Core
1
4
1
Neck Size = Listed size - 8
1
24
Face Plate
Retaining
Spring
3
Perforated Face
Retaining Spring
1
8
1
4
1B
32 (Typ.)
Perforated Face
22 7 x 22 7 Overall Face
8
8
3
3
Overall Diffuser = 23 4 x 23 4
T-Bar Module = 24 x 24
Face Plate
Retaining
Spring
.900
3/2006
One Way
Three Way
Four Way
PCD
B
B
Neck Size = Listed Size - 1
8
1. Available 2-Concealed
Finishes
2. Available Accessories4
Spring Latches
3. Construction Details
Duct Size +
Standard Finish: Auxiliary
(Accessories Shipped Unattached)
Available core patterns:
Panel
D7 Opposed Blade
Damper
3
01 White
1W,
2W, 2C (Corner), 3W and Duct
4W Size Square Neck:
14
A
Optional Finish
7600
D7 - Opposed blade damper - Steel . . . . . . . .337
Blade
BearingSeries has 3/16" diameter holes on
02 Aluminum paint
1/4" staggered centers
D7ABlade
- Opposed blade
damper - Aluminum
. . .337
Removable Air
Adjustable Curved
3
Optional
03 Black
Pattern Core
Air Pattern Controller
Mounting Spring
L9 - Equalizing gridDrop
. . . Face
. . . . . . . . . 8. . . . . . . . .334
B
22 (BBP) Black back pan/white face & border
TR
to round transition . . . . . . . . . . .338
28 Custom color
3 - Square
3
Overall Diffuser = 23 4 x 23 4
Round Neck:
B
T-Bar Module = 24 x 24
BDS - Butterfly damper . . . . . . . . . . . . . . . . . .335
RSD - Radial shutter damper . . . . . . . . . . . . .336
A
G3 - Equalizing grid . . . . . . . . . . . . . . . . . . . .337
1
4
5
8
1
8
1
2
1
1
2
1
3 2
A
B
B
A
1
4
1
8
.900
Face Plate
Retaining
Spring
B
1
32 (Typ.)
A
Duct Size + 1
4
5
Duct Size 8
1
8
2C
2W
3W
4W
Diameter H
Staggered
PCD-105
8
5
Ceiling Opening = Nominal Face Size - 8
T-Bar Module
Neck Size = Listed Size - 1
8
Overall Panel = T-Bar Module - 1
4
1
Neck Size = Listed Size - 8
T-Bar Module
Return1
3
3 *
4
Face Plate
Retaining Spring
3
(4 Per Unit)
5
Ceiling Opening = Nominal Face Size - 8
Neck Size = Listed Size - 1
Face Plate
8
Perforated Face Plate
Retaining
Perforated Face = Overall Diffuser - 11
Spring
16
7
16
28 *
15
8
1
28 *
5
18
11
4
5
18
Face Plate
Retaining
Spring
3
4*
15
8
PCD
2 - Concealed
Hinges
1
Neck Size = Listed Size - 8
3
4*
Face Plate
Retaining
Spring
Optional Drop Face
3
3
Overall Diffuser = 23 4 x 23 4
T-Bar Module
Perforated
Face
Plate= T-Bar
Overall
Panel
Module
- 1
T-Bar
Module
x 24
4= 24
3
1+1
Overall Diffuser = Nomial Face Size
Neck Size = Listed Size - 8
8
11
4
15
8
Face Plate
Retaining Spring
7
3 *
16
(4 Per Unit)4
Face Plate
Retaining Spring
(4 Per Unit)
T-Bar Module
1
Neck Size = Listed Size Overall Panel = T-Bar Module -8 1
4
1
Neck Size = Listed Size - 8
12 x 12
Retaining
Tile Size
Spring
Face
Plate
12 x 12
Retaining Spring
24 x 12
(4 Per Unit)
24 x 24
5 10 x 10
18
Face Plate
24 x 12
22 x 10
5
Retaining
1
9
Perforated Face Plate
9
* x 22
Perforated
Face Plate
24 x 24 8
22
3
Spring
T-Bar Module
3*
16
5
16
Neck Size
= Listed
SizeDiffuser
- 1 -2
4
Perforated
Face
= Overall
18
4
Perforated
= Overall
Diffuser
-2
8
*
7
3 Sizes
Perforated
Face Plate
Overall
PanelFace
= T-Bar
Module
- 1
Smaller Listed
Are
4
Overall Diffuser = Concealed T-Bar Tile 11
Size
16 Size
Face Plate
4Each Tile
Overall Diffuser = Concealed T-Bar
1 Tile Size
Available
For
Perforated
Face
=
Overall
Diffuser
Neck
Size = Listed Size - 8
5
Perforated Face
Plate
16
11
1
Retaining
Spring
* Distance
4 Of Duct Should Be Maintained as Closely As Possible 3
8 To Bottom Of Duct Should Be Maintained as Closely As Possible
* Distance To Bottom
1
Overall Diffuser = Nomial Face
SizeSize
+ 1 = Listed Size (4 Per Unit)
Neck
8
5
8
1
2 - Concealed
3
8
Perforated Face Plate
Optional Drop Face
4*
Hinges
15
3
3
7
3 *
Perforated Face Plate
8
Overall Diffuser = 23 4 x 23 4
16
4
11
Perforated Face = Overall Diffuser T-Bar Module = 24 x 24
3
Perforated Face Plate 16
*
Optional
Drop
Face
4
3
3
Overall Diffuser = 23 4 x 23 4
T-Bar Module = 24 x 24
5
18
15
8
135*
8
4
3
4*
3
7
16
Mounting
Spring
52 14 *
18
3*
4
Perforated
1 Face Plate
Neck Size = Listed Size 8
Perforated Face = Overall Diffuser - 11
16
Perforated Face Plate
1
Optional
Neck Size = Listed Size - 8Drop Face
3
3
Overall Diffuser = 23 4 x 23 4
T-Bar Module = 24 x 24
7
Ref.
16
9
16
7
7
x 22
8
8
Maintained as Closely3As Possible
3
x
23
Overall Diffuser = 23
4
4
T-Bar Module = 24 x 24
Overall Face = 22
5
18
9
16
3*
4
5
8
Mounting
Spring
3*
4
1
2 *
4
9
16
1
Neck Size = Listed Size - 8
7
Ref.
16
1
8
7
7
x 22
8
8
Retaining
Spring
PCD-106
1
8
9
16
Tile Size
x 12
Retaining
Face Plate 24
Spring (4 Per
24Unit)
x 24
1
*
4
7
7
x 22
8
8
3
3
Overall Diffuser = 23
4 x 23 4
T-Bar Module = 24 x 24
Retaining
Spring
12 x 712
16
24 x 12
Listed Size
10 x 10
Overall Diffuser = 23
Removable Perforated Face Plate
7
7
x 22
8
8
3
3
4 x 23 4
T-Bar Module = 24 x 24
Tile Size
Listed Size
24 x 12
22 x 10
12 x 12
Retaining
Spring
Panel
3
3
x 23
8
8
3 x 23 3
4
4
7
16
Overall Face = 22
Overall Diffuser = 23
22 x 10
22 x 22
1
8
Panel
1
*
4
Ref.
22 x 22
10 x 10
22 x 22
Overall Face = 23
7
Ref.
16
22 x 10
24 x 24
1
8
10 x 10
7
16
1 = 24 x 24
T-Bar
Neck Size = Listed
SizeModule
8
Neck Size = Listed Size -
Listed Size
Overall Face = 22
5
8
12 x 12
22 x 22
Panel
10 x 10
12 x 12
* Distance To Bottom Of Duct Should Be Maintained as Closely As Possible
24 x 12
22 x 10
1
Neck Size = Listed Size - 8
Mounting
Spring
5
18
Max. Listed Size For
Each Tile Size Shown.
3*
4
Listed Size
Tile Size
24 x 24
3
4
3
3
x 23
8
8
3 x 23 3
4
4
2 - Concealed
Hinges
24 x 24
x 22 Be Maintained as Closely As Possible
* Distance To Bottom
Of Duct 22
Should
Panel
22 x 10
Retaining
Spring
1
8
Overall Face = 23
Overall Diffuser = 23
7
16
24 x 24
24 x 12
2 - Concealed
Hinges
15
Return
- Perforated Ceiling Diffuser - Donn Fineline
8
Model
7000R-9 - LowPerforated
profile Face Plate
3
Mounting 4 *
Spring
3
4*
Mounting
Spring
Max. Listed Size For
5
Panel
1 8 Each Tile Size Shown.
Face Plate Retaining
Retaining
Listed9 Size
Tile Size
Spring (4 Per Unit)
Spring
3*
3
1 16
4 12 x 12
2 10* x 10
15
8
Face Plate
Retaining Spring
(4 Per Unit)
2 - Concealed
Hinges
Listed Size
10 x 10
22 x 10
22 x 22
T-Bar Module
2 - Concealed
Hinges
Retaining
Spring
15
8
5
18
Return - Perforated
Ceiling
Diffuser - T-bar Lay-in Perforated Face Plate
7
3 *
Face = Overall Diffuser - 11
Model 7000R-64 - All 16
sizes except 24" x Perforated
24"
16
5
18
Face Plate
Retaining
Spring
Perforated Face Plate
Optional Drop Face
3
3
Overall Diffuser = 23 4 x 23 4
Ceiling Opening = Nominal
Face
- 5 = 24 x 24
T-Bar
Module
8
Face Plate
Perforated
Face Plate
5
Neck Size = Nominal
Face -2
32
Retaining
Overall Diffuser = Nominal Face Size + 1 3
T-Bar Module8
Spring
1
Overall Panel = T-Bar Module - 4
1
Neck Size = Listed Size - 8
Perforated Face Plate
Overall Diffuser = Nomial Face Size + 1 3
8
Mounting
Spring
3 * 1 7
4 1 4 16
5
Neck Size
Listed
- 1
Ceiling Opening = Nominal
Face=Size
- Size
8
8
Neck Size = Listed Size - 1
8
11
4
Gasket
11
4
Gasket
5
32
5
18
1
28 * 5
1
8
Face Plate
Face Plate
Retaining
3/2006
Spring Retaining Spring
(4 Per Unit)
1
(TYP)
32
3/2006
1. Available Finishes
3. Construction Details
2. Available Accessories
Accessories are shipped unattached
Square Neck:
D7 - Opposed Blade Damper - Steel . . . . . . . .337
D7A - Opposed Blade Damper - Aluminum . .337
TR - Square to Round Transition . . . . . . . . . .338
Round Neck:
BDS - Butterfly Damper . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter Damper . . . . . . . . . . . . .336
Note:
Anodized Finish not available
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face & border
28 Custom color
13 3/8 x 13 3/8
6x6
8x8
14 x 14
15 3/8 x 15 3/8
6x6
8x8
16 x 16
17 3/8 x 17 3/8
6x6
8x8
9x9
10 x 10
20 x 20
21 3/8 x 21 3/8
6x6
8x8
9x9
10 x 10 12 x 12 14 x 14
24 x 12
25 3/8 x 13 3/8
6x6
8x6
9x6
36 x 12
37 3/8 x 13 3/8
6x6
8x6
9x6
48 x 12
49 3/8 x 13 3/8
6x6
8x6
9x6
15 x 15
16 3/8 x 16 3/8
18 x 18
19 3/8 x 19 3/8
21 x 21
22 3/8 x 22 3/8
24 x 24
25 3/8 x 25 3/8
36 x 24
37 3/8 x 25 3/8
48 x 24
49 3/8 x 25 3/8
6x6
6x6
6x6
6x6
6x6
6x6
8x8
8x8
8x8
8x8
8x8
8x8
9x9
9x9
9x9
10 x 10 12 x 12
10 x 10 12 x 12 14 x 14 15 x 15
10 x 6
12 x 6
14 x 6
16 x 6
18 x 6
10 x 6
12 x 6
14 x 6
16 x 6
18 x 6
10 x 6
12 x 6
14 x 6
16 x 6
16x6
9x9
10 x 10 12 x 12 14 x 14 15 x 15
9x9
10 x 10 12 x 12 14 x 14 15 x 15
9x9
10 x 10 12 x 12 14 x 14 15 x 15
PCD
16x16
18 x 18
16x16
18 x 18
16x16
18 x 18
18 x 6
24 x 12
Actual Overall
Face Size
11 15/16 x 11 15/16
8x8
6x6
8x6
9x6
35 15/16 x 11 15/16
6x6
8x6
9x6
47 15/16 x 11 15/16
6x6
8x6
12 x 6
23 15/16 x 23 15/16
36 x 24
35 15/16 x 23 15/16
48 x 24
47 15/16 x 23 15/16
48 x 12
6x6
23 15/16 x 11 15/16
24 x 24
36 x 12
6x6
6x6
6x6
8x8
8x8
8x8
10 x 6
12 x 6
14 x 6
16 x 6
18 x 6
10 x 6
12 x 6
14 x 6
15 x 6
16x6
14 x 6
16 x 6
18 x 6
9x9
10 x 10 12 x 12 14 x 14 15 x 15
16x16
18 x 18
9x9
10 x 10 12 x 12 14 x 14 15 x 15
16x16
18 x 18
9x9
10 x 10 12 x 12 14 x 14 15 x 15
16x16
18 x 18
18x6
24 x 12
Actual Overall
Face Size
11 15/16 x 11 15/16
8x8
6x6
8x6
9x6
35 15/16 x 11 15/16
6x6
8x6
9x6
47 15/16 x 11 15/16
6x6
8x6
9x6
23 15/16 x 23 15/16
36 x 24
35 15/16 x 23 15/16
48 x 24
47 15/16 x 23 15/16
48 x 12
6x6
23 15/16 x 11 15/16
24 x 24
36 x 12
6x6
6x6
6x6
8x8
8x8
8x8
10 x 6
12 x 6
14 x 6
15 x 6
16 x 6
18 x 6
10 x 6
12 x 6
14 x 6
15 x 6
16 x 6
18 x 6
10 x 6
12 x 6
14 x 6
15 x 6
16 x 6
18 x 6
9x9
10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 18 x 18
9x9
10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 18 x 18
9x9
10 x 10 12 x 12 14 x 14 15 x 15 16 x 16 18 x 18
22 7/8 x 22 7/8
8x8
9x9
10 x 10
12 x 12
14 x 14
15 x 15
22 x 22
PCD-107
8" x 6"
9" x 6"
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
PCD
8" x 8"
10" x 6"
CFM
Pt
NC
12" x 6"
9" x 9"
14" x 6"
10" x 10"
15" x 6"
16" x 6"
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
Throw
4-Way
3-Way
2-Way
1-Way
200
.003
300
.006
400
.010
500
.016
600
.022
700
.030
1-1-3
1-2-3
2-3-4
3-4-5
65
.015
<
2-3-4
2-3-4
3-4-5
4-5-7
100
.03
<
3-4-5
3-5-6
4-5-7
5-7-9
130
.06
20
3-5-6
4-5-7
5-7-9
6-8-11
165
.09
25
4-5-7
5-7-9
6-9-12
7-11-14
200
.13
25
4-6-8
6-8-10
7-10-13
8-12-16
230
.18
30
2-4-5
2-3-4
3-5-6
4-5-7
100
.016
<
3-5-6
3-5-6
4-6-8
5-7-9
150
.032
<
50
.015
<
2-3-4
2-3-4
3-4-5
3-5-6
90
.016
<
3-4-5
3-4-5
3-5-6
4-5-7
115
.016
<
3-5-6
3-5-6
4-6-7
4-6-8
140
.016
<
2-3-4
3-5-6
4-6-8
5-7-9
75
.03
<
100
.06
20
3-4-5
3-4-5
3-5-6
4-6-8
130
.033
<
3-5-6
4-5-7
4-6-8
5-7-10
180
.06
20
3-5-6
4-5-7
4-6-8
5-7-9
175
.042
<
4-6-8
5-7-9
6-8-11
6-9-12
230
.06
20
4-5-7
4-6-8
5-7-9
5-7-10
210
.035
<
3-5-6
4-6-8
6-8-11
6-9-12
125
.09
25
150
.13
25
175
.17
30
4-5-7
4-6-8
5-7-10
6-9-12
220
.09
25
4-6-8
5-7-10
7-10-13
8-12-15
265
.13
30
5-7-9
5-7-10
7-10-13
8-12-15
290
.09
25
5-7-10 6-9-12
6-9-12 8-12-15
8-12-15 9-14-18
9-14-18 11-16-22
350
405
.137
.18
30
35
4-5-7
4-6-8
6-8-11
6-9-12
200
.06
20
4-6-8
5-7-9
7-10-13
8-12-15
250
.09
25
5-7-9
5-7-10
6-9-12
7-10-13
275
.06
20
5-7-10 6-9-12
6-8-11 7-10-13
7-11-14 8-12-16
8-12-16 10-15-19
345
415
.10
.14
25
30
800
.040
200
.23
35
5-7-9
5-7-10 6-9-12
6-9-12 7-10-13 7-11-14
7-11-14 8-12-16 9-14-18
9-13-17 10-15-19 11-16-22
310
350
400
.18
.24
.30
35
40
40
5-7-9
6-8-11
6-8-11 7-11-14
8-12-15 9-14-18
9-14-18 11-16-22
300
350
.13
.18
30
35
7-10-13
8-12-16
11-16-21
12-18-24
400
.24
40
8-12-15
10-15-19
12-18-24
14-21-28
520
.30
40
4-6-8
6-8-11
6-9-12 7-11-14 8-12-16
5-7-10 7-10-13 8-12-15 9-14-18 10-15-20
7-10-13 8-12-16 10-15-20 12-17-23 13-19-26
8-12-16 10-15-20 12-18-24 14-21-28 16-24-32
9-14-18
11-16-22
15-20-23
18-27-36
7-10-13
8-12-16
10-15-19
11-16-22
485
.19
35
8-12-15
9-14-18
11-16-22
13-19-25
550
.25
40
200
-.013
300
-.03
400
-.05
500
-.08
600
-.011
700
-.015
800
-.020
8" x 6"
CFM
NC
65
<
100
<
130
<
165
<
200
20
230
25
265
30
CFM
NC
110
<
170
<
CFM
NC
140
<
CFM
NC
200
<
8" x 8"
9" x 9"
10" x 6"
10" x 10"
12" x 6"
12" x 12"
15" x 15"
18" x 18"
20" x 20"
22" x 10"
22" x 22"
34" x 22"
46" x 22"
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
CFM
NC
50
<
90
<
80
<
100
<
310
<
450
<
555
<
75
<
130
<
125
<
210
<
150
<
300
<
470
<
675
<
100
<
175
<
225
<
165
<
275
<
200
<
400
<
625
20
900
20
125
<
220
20
280
20
205
20
345
20
250
20
500
20
780
25
150
20
265
25
335
25
245
25
415
25
300
25
600
25
760
25
910
30
1680
28
2015
33
1405
<
2105
<
2810
23
3510
30
4210
38
2595
28
350
30
700
30
550
35
400
35
800
35
2215
42
1345
20
2075
20
485
30
330
35
1940
38
1350
30
1010
<
1555
<
290
30
450
35
1660
33
1125
25
670
<
1040
<
390
30
350
35
1250
40
1385
28
610
20
310
30
3115
35
1575
35
1065
35
2350
38
3635
40
4915
42
9-13-17
10-15-20
13-19-25
15-22-29
620
.31
40
200
30
1090
35
1110
20
455
<
175
25
935
30
830
<
305
<
7-11-14
9-14-18
12-18-24
14-21-28
450
.30
40
7-11-14
9-13-17
11-16-21
13-19-25
465
.24
40
225
.29
40
5-7-9
6-8-10
6-9-12 7-10-13
8-12-15 8-12-16
9-14-18 11-16-21
265
300
.23
.29
35
40
Neck Size
Ak
6" x 6"
900
.050
1800
40
1215
40
2690
42
4150
45
5615
445
PCD-108
3/2006
3/2006
12" x 12"
14" x 14"
15" x 15"
16" x 16"
18" x 18"
CFM
Pt
NC
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
4-Way
3-Way
2-Way
1-Way
CFM
Pt
NC
Throw
Throw
4-Way
3-Way
2-Way
1-Way
200
.003
300
.006
3-4-5
3-4-5
4-6-8
5-7-9
200
.016
<
3-5-6
4-6-8
6-8-11
6-9-12
300
.045
20
150
.016
<
225
.05
<
400
.010
300
.06
20
500
.016
375
.10
25
4-6-8
6-8-11
6-8-11 7-10-13
7-11-14 9-13-17
8-12-16 11-16-21
400
500
.066
.10
25
25
600
.022
700
.030
800
.040
900
.050
7-10-13
8-12-16
11-16-21
13-19-25
600
.15
30
8-12-15
9-14-18
12-18-24
15-22-29
700
.20
35
9-14-18
11-16-21
14-21-28
17-25-33
800
.26
40
10-15-20
12-18-24
18-27-33
19-28-38
900
.33
40
9-14-18
10-15-20
12-19-26
15-23-30
935
.16
35
10-15-20
11-17-23
16-23-31
17-25-35
1090
.21
40
12-18-24
13-19-27
18-26-36
19-28-39
1250
.28
40
14-21-28
16-23-31
19-29-39
21-31-43
1405
.35
45
10-15-21
13-19-26
17-25-32
18-27-36
1350
.16
35
13-18-27
15-22-30
19-26-34
19-28-37
1575
.22
40
450
.14
30
525
.19
35
600
.25
40
3-5-6
3-5-6
5-7-9
6-9-12
270
.018
<
4-6-8
5-7-10 6-9-12 8-12-15 9-13-17
5-7-9
6-9-12 8-12-15 9-14-18 11-16-22
6-9-12 8-12-16 11-16-21 12-18-24 15-22-29
8-12-16 10-15-20 12-18-24 15-22-29 17-25-33
410
545
680
815
950
.04
.07
.11
.16
.22
20
25
28
33
37
10-15-20
13-19-25
17-25-33
18-27-36
1090
.28
40
4-6-8
5-7-9
6-9-12
7-11-14
355
.018
<
13-19-26
15-23-30
20-30-40
21-31-42
1415
.280
40
4-5-7
4-5-9
5-7-10
6-9-12
310
.018
<
5-7-9
5-7-11
6-10-12
7-10-16
450
.019
<
4-6-9
6-9-12
5-8-11 6-10-13
6-9-13 8-12-18
8-12-18 10-15-22
470
625
.05
.07
20
25
7-11-14
8-13-16
11-17-22
13-19-26
780
.11
30
10-15-20
11-16-22
16-24-32
18-27-36
10-15-20
11-16-22
16-22-31
16-24-32
1060
.155
35
12-18-24
13-19-26
20-29-39
22-32-43
12-17-23
13-19-26
18-27-36
19-28-38
1240
.212
40
14-21-28
16-24-31
23-34-45
25-37-49
14-20-28
18-25-36
21-34-40
24-35-42
1800
.29
40
16-24-32
18-27-36
26-39-52
28-42-56
675
.31
40
12-17-23
14-20-27
18-27-36
21-31-42
1225
.36
43
PCD
15-23-30
18-26-35
23-33-43
23-34-45
1595
.350
45
16-22-31
19-29-39
24-34-44
26-36-46
2025
.36
45
18-27-36
21-31-41
29-43-58
30-45-60
PCD-109
3/2006
Surface Mounted
T-bar Lay-in
Concealed Spline
Tegular T-bar
Donn Fineline
Air Outlets shall be aluminum model 7000 manufactured by METALAIRE. Units shall consist of aluminum 51% free area perforated face and an aluminum
border and backpan. Perforated holes shall be 3/16" diameter on 1/4" staggered centers.
Outer border of units shall be extruded aluminum construction. The perforated face shall be removable allowing access to aluminum curved blade pattern
controller mounted into the neck of the diffusers. Face shall be secured in place with tension spring clips. Pattern controller blades shall be individually
adjustable and allow the discharge pattern to be adjustable from vertical to horizontal. Pattern controller blades shall pivot in friction mounting
retainers. Retainers shall hold the deflector blade position throughout the specified operating range of the device. Metal friction wires are not acceptable.
Outlets shall be available in 1, 2-way opposite, 2-way corner, 3, and 4-way directional air patterns. Units shall have square inlets.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
PCD
Surface Mounted
T-bar Lay-in
Concealed Spline
Tegular T-bar
Donn Fineline
Air Inlets shall be aluminum model 7000R manufactured by METALAIRE. Units shall consist of aluminum 51% free area perforated face and an aluminum
border and backpan. Perforated holes shall be 3/16" diameter on 1/4" staggered centers. Units shall be designed for use in ducted return or exhaust
applications.
Outer border of units shall be extruded aluminum construction. The perforated face shall be removable allowing access to interior of diffuser. Face shall
be secured in place with tension spring clips.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
PCD-110
3/2006
Available Finishes
Standard
Standard
4W - 4-way
14" x 14"
Model
Air Pattern
Available Options
Square Options
01 - White
D7A
1W - 1-way
02 - Aluminum
L9
Equalizing Grid
6"
18" x 18"
2W - 2-way
03 - Black
TR
thru
20" x 20"
3W - 3-way
18"
21" x 21"
2C - 2-way corner
28 - Custom Color
G3
Equalizing Grid
24" x 12"
BDS
24" x 24"
RSD
Induction Vanes
48" x 24"
D3
SD3
Module
Options
16" x 16"
Available Neck
Options
D7
Air Pattern
Available Finishes
Standard
Standard
4W - 4-way
Available Options
Square Options
01 - White
Options
Round Options
D7A
1W - 1-way
02 - Aluminum
L9
Equalizing Grid
6"
24" x 12"
2W - 2-way
03 - Black
TR
thru
24" x 24"
3W - 3-way
24 - Mill
18"
48" x 12"
2C - 2-way corner
28 - Custom Color
G3
Equalizing Grid
BDS
RSD
Induction Vanes
D3
SD3
Options
D7
12" x 12"
7000-6 T-bar Lay-in
Round Options
Available Neck
PCD
Model
7000-1 Flush Surface Mount
Available Neck
Module
Available Finishes
Model
Available Options
Standard
Square Options
D7
Options
16" x 16" 02 - Aluminum
D7A
L9
Equalizing Grid
TR
thru
18"
G3
Equalizing Grid
24" x 12"
BDS
24" x 24"
RSD
Induction Vanes
48" x 24"
D3
SD3
Available Neck
Module
Round Options
Available Finishes
Available Options
Standard
01 - White
Options
Square Options
D7
D7A
12" x 12"
02 - Aluminum
L9
6"
24" x 12"
03 - Black
TR
thru
24" x 24"
18"
48" x 12"
28 - Custom Color
G3
Equalizing Grid
BDS
RSD
Induction Vanes
D3
SD3
Round Options
PCD-111
3/2006
T-Bar Module
1
Overall Return Size = T-Bar Module - 4
1
4 TYP
T-Bar By Others
Front View
Model PRTB-6
Standard Finish: 01 White
T-Bar Module
7
16
PCD
Front View
Perforated Face Return
3/16 Diameter Holes ON
1/4 Staggered Centers
T-Bar Module
T-Bar Module
1
Overall Return Size = T-Bar Module - 4
1
4 TYP
T-Bar By Others
1
Overall Return Size = T-Bar Module - 4
Front View
T-Bar By Others
7
16
Front View
Perforated Face Return
3/16 Diameter Holes ON
1/4 Staggered Centers
3
16
T-Bar Module
1
Overall Return Size = T-Bar Module - 4
Front View
7
16
T-Bar Module
1
Overall Return Size = T-Bar Module - 4
1. Available Finishes
StandardT-Bar
Finish:
By Others
01 White
Optional Finish
02 Aluminum paint
03 Black
28 Custom color
2. Construction Details
T-Bar Module
1
Overall Return Size = T-Bar Module - 4
PCD-112
Front View
T-Bar Module
1
Overall Return Size = T-Bar Module - 4
3
16
Front View
3
16
Front View
3/2006
300
-.03
400
-.05
500
-.08
525
<
700
20
420
20
505
25
590
30
800
-.19
170
<
CFM
NC
350
<
335
<
700
-.15
CFM
NC
CFM
NC
250
<
600
-.11
670
35
CFM
NC
CFM
NC
CFM
NC
PCD
Aluminum
PRTB-6 - T-bar Lay-in
PRTB-8 - Tegular T-bar
PRTB-9 - Donn Fineline
Air Inlets shall be aluminum model PRTB or steel SPRTB manufactured by METALAIRE. Units shall be designed for use in a non-duct return or exhaust
applications. Units shall consist of a 51% free area perforated face. Perforated holes shall be 3/16" diameter on 1/4" staggered centers.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Module
Available Finishes
Model
Module
Available Finishes
Standard
12" x 12"
Standard
01 - White
01 - White
12" x 12"
24" x 12"
SPRTB-6 T-bar Lay-in
24" x 24"
SPRTB-8 Tegular T-bar
Options
02 - Aluminum
24" x 24"
36" x 24"
36" x 24"
SPRTB-9 Donn Fineline
Options
24" x 12"
PRTB-6 T-bar Lay-in
02 - Aluminum
48" x 12"
03 - Black
48" x 12"
03 - Black
48" x 24"
24 - Mill
48" x 16"
24 - Mill
28 - Custom Color
48" x 24"
28 - Custom Color
PCD-113
PCD
Model 7300-6
Standard Finish: 01 White
25
8
1. Available Finishes
Standard Finish:
01 White with black dispersion disc and
plenum interior
Perforated Face
T-Bar Module = 24 x 24
2. Construction Details
Neck is pre-scored to 5", 6", 7", 8", 10", 12", 14"
& 15"
Face is non-removable
Inlet collars are provided by others
7300 series has 3/16" diameter holes on 1/4"
staggered centers
1
32
PCD-114
Perforated Face
T-Bar Module = 24 x 24
3/2006
3/2006
5"
6"
7"
8"
9"
10"
12"
14"
15"
200
.002
300
.006
400
.010
CFM
Pt
Throw
NC
25
.003
1-1-1
<
40
.008
1-1-1
<
55
.016
1-1-1
<
CFM
Pt
Throw
NC
50
.005
1-1-1
<
80
.013
1-1-3
<
105
.026
1-1-4
<
130
.014
1-1-3
-
175
.026
1-2-5
-
CFM
Pt
Throw
NC
CFM
Pt
Throw
NC
CFM
Pt
Throw
NC
CFM
Pt
Throw
NC
40
.004
1-1-1
<
70
.006
1-1-2
<
105
.013
1-1-3
<
110
.008
1-2-3
<
160
.018
1-2-4
<
90
.007
1-1-2
-
CFM
Pt
Throw
NC
155
.009
1-2-4
<
CFM
Pt
Throw
NC
245
.015
1-3-9
<
CFM
Pt
Throw
NC
60
.009
1-1-1
<
210
.010
1-2-6
<
235
.021
1-2-5
20
320
.022
1-3-9
20
370
.034
2-5-11
23
500
.016
70
.025
1-1-3
<
80
.033
1-1-4
<
135
.036
1-2-4
20
160
.050
1-2-5
23
220
.042
2-2-5
22
265
.060
2-3-6
26
80
.016
1-1-4
<
100
.027
1-2-4
<
140
.026
1-2-5
<
175
.037
2-2-5
20
215
.033
1-2-5
20
315
.039
1-2-7
24
425
.039
2-5-11
24
490
.060
3-6-13
28
600
.022
270
.052
2-3-6
23
700
.030
95
.045
1-1-4
<
535
.063
3-6-13
28
610
.093
4-8-16
33
120
.076
1-2-6
24
210
.088
2-3-7
30
240
.115
2-3-8
34
135
.049
1-3-6
26
155
.066
2-3-7
30
210
.054
2-3-6
23
245
.073
2-3-8
26
380
.111
3-4-8
29
185
.068
1-3-6
26
310
.083
2-3-8
30
470
.086
2-5-11
30
550
.118
3-6-13
34
735
.135
5-10-18
38
860
.185
7-11-23
43
640
.091
4-8-16
32
750
.124
5-9-18
36
900
.050
110
.060
1-1-5
21
115
.035
1-2-5
22
325
.075
2-3-7
26
390
.059
2-3-9
27
800
.040
1000
.062
138
.094
1-3-6
27
175
.078
2-3-8
35
196
.105
2-4-10
38
280
.096
2-4-10
30
315
.121
3-5-11
34
350
.150
3-6-12
38
435
.135
3-4-10
34
490
.171
3-5-12
38
855
.162
7-11-23
40
960
.210
9-13-27
45
350
.105
2-4-10
34
630
.155
4-7-14
38
980
.240
9-13-27
48
395
.134
3-5-11
38
705
.194
6-9-18
42
265
.140
2-4-10
37
440
.166
3-6-13
41
545
.212
4-7-14
41
785
.240
7-11-21
45
1070
.253
10-16-32
48
Neck Size
PCD
1105
1225
.305
.375
10-16-32 11-16-33
53
55
Air Outlets shall be aluminum face model 7300 or steel face model 7300 AF manufactured by METALAIRE. Units shall consist of 51% free area perforated
face fixed to a formed fiberglass backpan. Exposed fiberglass backpan shall have an aluminum foil liner. The outlets backpan shall be factory scored to
allow field installation of a tab lock collar or spin-in fittings.
Perforated holes shall be 3/16" diameter on 1/4" staggered centers.
Unit shall generate a 360 horizontal pattern with a fixed round pattern disk mounted on the inside face of the perforated face.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Module
Finishes
24" x 24"
Standard
PCD-115
25
8
Perforated Face
T-Bar Module = 24 x 24
3/2006
Product Details
The series 7350 perforated supply diffuser is an
economical diffuser with a fiberglass plenum
designed to allow field installation of the inlet
collar (by others)
PCD
1
32
Perforated Face
25
8
Perforated Face
T-Bar Module = 24 x 24
T-Bar Module = 24 x 24
Model 7350-1
Standard Finish: 01 White
1
32
Perforated Face
T-Bar Module = 24 x 24
1
32
Perforated Face
T-Bar Module = 24 x 24
1. Available Finishes
2. Available Options
Standard Finish:
01 White
Neck is pre-scored to
5", 6", 7", 8", 10", 12", 14" & 15"
Return diffusers have no pattern controllers
Faces are hinged and removable
Models: 7350-6, 7350-6 AF & 7350-8 include
4 black painted, individually adjusted pattern
controllers, mounted on rear of the
perforated face
7350 series has 3/16" diameter holes on
1/4" centers
Inlet Collar (By Others)
1
32
PCD-116
Perforated Face
T-Bar Module = 24 x 24
1
32
T-Bar Module = 24 x 24
6"
8"
10"
12"
14"
fpm Neck
Velocity Pv
300
.006
400
.010
500
.016
600
.023
700
.031
800
.040
1000
.062
4-Way
3-Way
2-Way
1-Way
1-1-3
1-1-3
1-2-4
1-2-5
1-1-4
1-2-4
1-2-5
1-3-5
1-2-4
2-2-5
2-3-5
3-4-6
1-2-5
2-3-6
2-4-6
3-4-7
1-3-6
2-3-6
3-4-7
3-4-8
2-3-7
2-3-8
3-4-9
3-5-9
2-3-8
2-4-8
3-4-9
3-5-10
4-Way
3-Way
2-Way
1-Way
1-1-3
1-2-3
1-2-4
2-3-5
1-2-5
1-2-5
1-3-5
2-4-5
2-2-5
2-3-5
2-4-6
3-4-7
2-3-6
2-3-6
3-4-7
3-5-8
2-3-8
3-3-8
3-4-9
3-5-10
2-4-10
3-4-11
3-5-12
3-6-13
3-5-11
3-5-12
4-6-13
4-6-14
4-Way
3-Way
2-Way
1-Way
1-2-4
1-2-4
1-2-5
2-3-6
1-2-5
1-3-6
2-3-6
2-4-7
2-3-6
2-3-7
3-4-8
3-5-9
2-3-7
2-4-8
3-4-8
3-5-10
3-4-8
3-5-9
3-6-10
4-7-11
3-4-10
3-5-12
3-6-14
4-7-14
3-5-12
3-6-13
4-7-15
5-9-16
4-Way
3-Way
2-Way
1-Way
1-2-4
2-3-5
2-3-6
3-4-8
2-2-8
2-3-8
3-4-8
3-5-9
3-3-8
3-4-9
3-5-11
4-6-12
3-5-10
3-5-11
3-6-12
4-7-13
3-5-11
4-6-13
4-7-13
5-8-14
4-6-12
4-7-14
5-8-15
6-9-16
5-7-14
5-8-15
6-9-16
7-10-18
4-Way
3-Way
2-Way
1-Way
2-3-6
2-4-7
2-5-8
3-5-9
3-4-8
3-5-9
3-5-10
4-8-11
3-5-11
3-6-12
3-7-13
4-8-14
4-6-13
4-7-14
5-8-15
6-9-16
CFM
Pt
NC
Throw
CFM
Pt
NC
Throw
CFM
Pt
NC
Throw
CFM
Pt
NC
Throw
CFM
Pt
NC
Throw
60
.012
<
80
.022
<
105
.017
<
140
.031
<
165
.020
<
220
.035
<
235
.032
<
320
.039
<
315
.059
<
425
.068
23
100
.034
<
175
.048
<
270
.053
22
390
.090
25
535
.108
29
115
.045
-
210
.070
21
325
.077
28
470
.131
29
640
.156
34
135
.062
20
155
.083
24
245
.095
26
380
.106
33
550
.180
35
750
.213
39
195
.131
31
280
.124
30
350
.195
36
435
.138
37
630
.236
40
855
.277
44
Models 7350-8
545
.218
43
785
.367
46
1070
.435
50
Neck
Size
6"
8"
10"
12"
14"
fpm Neck
Velocity Pv
300
.006
400
.010
500
.016
600
.023
700
.031
800
.040
1000
.062
4-Way
Throw 3-Way
2-Way
1-Way
1-1-3
1-1-3
1-2-4
1-2-5
1-1-4
1-1-4
1-2-5
1-3-6
1-2-5
2-3-6
2-3-7
3-4-7
1-2-6
2-3-6
2-4-9
3-4-9
1-4-7
2-3-7
3-4-10
4-4-11
2-4-8
3-3-9
3-3-10
4-4-11
3-4-8
4-4-9
3-4-10
4-4-12
4-Way
Throw 3-Way
2-Way
1-Way
1-1-4
1-2-4
1-3-4
2-3-6
1-2-6
1-2-6
1-3-6
3-4-7
2-3-5
2-3-6
2-4-8
4-4-9
2-4-6
2-4-7
3-4-9
4-5-10
3-4-8
4-3-8
3-4-10
4-5-11
3-5-10
4-4-11
3-5-12
4-5-12
4-5-11
4-4-12
4-5-13
5-5-12
4-Way
Throw 3-Way
2-Way
1-Way
1-1-5
1-3-5
1-3-5
3-4-6
1-4-6
2-4-6
2-3-6
3-4-7
3-4-6
3-4-8
4-5-8
5-5-9
3-4-8
4-4-8
4-5-9
5-5-10
4-2-9
4-5-9
4-6-11
5-7-12
5-5-11
5-5-12
5-6-14
6-7-15
5-5-14
5-7-14
5-6-15
6-9-17
4-Way
Throw 3-Way
2-Way
1-Way
1-4-5
3-4-6
3-5-6
4-5-10
3-4-9
3-4-9
4-5-9
5-7-12
5-5-10
5-5-10
5-5-11
6-8-15
5-6-11
5-6-11
5-6-12
6-9-13
5-6-11 6-8-12
5-7-11 5-8-13
5-7-12 6-8-14
6-10-14 7-12-16
6-9-15
6-9-16
6-9-17
9-13-19
4-Way
Throw 3-Way
2-Way
1-Way
2-5-7
3-6-8
3-6-8
4-6-11
CFM
Pt
NC
60
.010
<
CFM
Pt
NC
105
.014
<
CFM
Pt
NC
165
.016
<
CFM
Pt
NC
235
.028
<
CFM
Pt
NC
320
.034
<
80
.017
<
140
.026
<
220
.029
<
315
.051
<
425
.059
23
100
.027
<
175
.040
<
270
.044
21
390
.078
24
535
.094
29
115
.036
<
210
.058
20
325
.064
27
470
.113
28
640
.134
33
135
.049
20
245
.078
25
380
.087
32
550
.155
34
750
.185
36
155
.065
23
280
.120
28
435
.114
34
630
.203
37
855
.240
40
195
.103
29
350
.160
33
545
.179
40
785
.316
44
PCD
3/2006
1070
.376
47
Aluminum Face
7350-6 AF - T-bar Lay-in
Air Outlets shall be aluminum face model 7350 or steel face model 7350 AF manufactured by METALAIRE. Units shall consist of 51% free area perforated
face fixed to a formed fiberglass backpan. Perforated holes shall be 3/16" diameter on 1/4" staggered centers. Exposed fiberglass backpan shall have an
aluminum foil liner. The outlets backpan shall be factory scored to allow field installation of a tab lock collar or spin-in fittings
Outer border of units shall be extruded aluminum construction. The perforated face shall be hinged allowing access to four adjustable pattern controllers
mounted onto the inside face of the outlet. Face shall be secured in place with tension spring clips. Pattern controller blades shall be individually
adjustable and allow the discharge pattern to be adjustable from vertical to horizontal.
Outlets shall be field adjustable allowing 1, 2-way opposite, 2-way corner, 3, and 4-way directional air patterns.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Module
Model
Module
Standard
Finishes
01 - White
Finishes
Standard
24" x 24"
01 - White
PCD-117
3/2006
ake Tab
2 - Concealed
Hinges
3
8
op Face
0-1 DF)
Supply
2 Concealed Spring Latches
Face
DF)
2 - Concealed
Hinges
3
8
Plenum
Earthquake Tab
1
3
8
Tab
1
3
8
1
8
Border 1
Perforated Face
Pattern Controller
3
Ceiling Opening = 23 3
4 x 23 4
3
Overall Diffuser = 25 3
8 x 25 8
Plenum
Earthquake Tab
2 - Concealed
Hinges
1
38
Perforated Face
Plenum
Earthquake Tab
Model 7500-1
2 - Concealed
Hinges
3
8
2 - Concealed
Hinges
3
8
1
24
Tab
2 - Concealed
Plenum
Earthquake
Tab
Fixed 360R
Round Air Contr
2 - Concealed
Hinges
Dimensions are in inches
Hinged, Removable
Border 1 DF
Perforated Face
Optional Drop Face
3
Ceiling Opening 11 3
4 x 11 4
3
3
Overall Diffuser 13 8 x 13 8
1 - Concealed Spr
1
24
Hinged, Remov
Perforated F
Fixed 360Radial
Round Air Controller
1
24
Plenum
Earthquake
Tab
Fixed 36
Round Air
2 - Concealed
Hinges
Hinged, Removable
Border 1 DF
Perforated Face
Optional Drop Face
3
Ceiling Opening 11 3
4 x 11 4
3
Overall Diffuser 13 3
x
13
8
8
1
24
1 - Conceal
Hinged, Re
Perfora
2 - Concealed
Hinges
Fixed 360Radial
Round Air Controller
Plenum
2 41
Earthquake
Tab
Pattern Controller
3
Overall Diffuser = 23 3
4 x 23 4
Overall Diffuser = 11 34 x 11 34
Concealed
Hinges
Fixed 360
Round Air Co
Hinged, Re
T-Bar Module = 12 x 12
T-Bar Module = 24 x 24
PCD-118
Fixed 360Radial
Round Air Controller
7500
ake Tab
Series 7500
Product Details
Series 7500 perforated supply diffusers have 4
adjustable pattern controllers mounted on the
face of the diffuser. Pattern controllers are
adjustable from a horizontal to vertical
discharge pattern
PCD
2 - Concealed
Fixed 360Radial
Plenum
Earthquake
Fixed
3/2006
Earthquake Tab
2 Concealed
Hinges
Plenum
1
38
Pattern Controller
3
8
3
Overall Diffuser = 233
4 x 234
e Tab
num
2 Concealed
Hinges
ed Face
Concealed
Spring
Latches
3
8
Earthquake Tab
Pattern Controller
Fixed 360Radial
Round Air Controller
2 Concealed
Hinges
Plenum
1
38
Fixed 360Radia
Round Air Contro
3
8
3
Overall Diffuser = 233
4 x 234
11 34 x 11 34
Concealed
Spring
Latches
Concealed
Hinges
Plenum
Earthquake Tab
3
8
Fixed 360Rad
Round Air Cont
2 Concealed
Spring Latches
Earthquake Tab
3
Overall Diffuser = 233
4 x 234
Tab
num
2 Concealed
Spring Latches
Plenum
1
38
Pattern Controller
PCD
3
8
Return
2 Concealed
Spring Latches
ated Face
3
8
Plenum
Earthquake Tab
2 Concealed
Spring Latches
2 Concealed
2 - Concealed
Hinges
Spring
Latches
1
8
2 Concealed
Spring Latches
2 - Concealed Hinges
1
8
3
8
Earthquake Tab
1
38
13
3 x -23
Border 1
O.D.
Overall Diffuser = 23
4 84
Perforated Face
3
Ceiling Opening = 23 3
4 x 23 4
3
1
Overall Diffuser = 25 3
x
25
38
8
8
Border 1
Perforated Face
3
Ceiling Opening = 23 3
4 x 23 4
3
Overall Diffuser = 25 3
8 x 25 8
3
8
3
8
2 Concealed
Spring Latches
2 - Concealed Hinges
1
38
Plenum
Earthquake Tab
3
33
4 x 23 4
Perforated Face
1
2 - Concealed Hinges
38
Perforated Face
1
8
1
24
3
8
Hinged, Removable
Perforated Face
Earthquake Tab
3
Ceiling Opening 11 3
4 x 11 4
Overall Diffuser 13 3 x 13 3
8
8
1Hinges
2 - Concealed
24
Hinged, Removable
Perforated Face
1
2 - Concealed2Hinges
4
Border 1 DF
Optional Drop Face
Ceiling Open
Hinged, Removable
Perforated Face
Ceiling Op
Plenum
Earthquake Tab
2 - Concealed Hinges
3
Overall Diffuser = 23 3
4 x 23 4
2 - Concealed Hinges
31
8
2 41
Plenum
Earthquake Tab
2 - Concealed Hinges
Perforated Face
Nominal RoundOverall
Neck Diffuser = 23 3 x 23 3
4
4
O.D. - 81
Plenum
Earthquake Tab
2 41
Hinged, Removable Pe
1
2 Concealed
2 Hinges
4
Ceilin O enin 11 3 x 11 3
Hinged, Removable
PCD-119
Plenum
Earthquake Tab
2 Concealed
Spring Latches
1
38
Return - Round Neck - Face Mounted - T-bar Lay-in - 24" x 24"2 Concealed Hinges
Model 7500R-8
- Steel backpan & face
3
8
Removable
Perforated Face
Model 7500R-8 AF - Steel backpan & aluminum
face
3
3
234
Overall Diffuser
= 23 4
Model 7500R-8 AL - Aluminum
backpan
&xface
1
38
1
38
Nominal Round
Neck O.D. - 81
2
Earthquake Tab
3
Overall Diffuser = 23 3
4 x 234
24 x 24
2 Concealed
Spring Latches
Nominal Round
Neck O.D. - 1
8
Earthquake Tab
1
38
Nominal Round
Neck O.D. - 1
8
2 Concealed
Spring Latches
2 Concealed
Spring Latches
3
Overall Diffuser = 23 3
4 x 234
3
8
3
Overall Diffuser = 23 3
4 x 234
24 x 24
2 Concealed
Spring Latches
Standard Finish:
01 White (border only for 7500-1)
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face & border
28 Custom color
3
8
2. Available Accessories
3. Construction Details
Notes for Models 7500R (-1, -6, -8, -9) 7500R-1 DF, 7500R AF (-1, -6, -8, -9) 7500R AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face & border
22 and white border (for 7500R-1 models only)
28 Custom color
PCD-120
2 Concealed
Spring Latches
3
8
Notes for Models 7500 (-1, -6, -8, -9) 7500-1 DF, 7500 AF (-1, -6, -8), 7500 AL (-6, -8)
1. Available Finishes
Earthquake Tab
1
38
24 x 24
d
hes
Plenum
Plenum
Metric
2. Available Accessories
All accessories shipped unattached
Square Necks:
OBD - Opposed blade damper - Steel . . . . . . .334
OBDA - Opposed blade damper - Aluminum . .334
Round Neck:
BDS - Butterfly damper . . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter damper . . . . . . . . . . . . .336
3. Construction Details
Available only in listed sizes
7500R series have 3/16" diameter holes on
1/4" staggered centers
2 14
Plenum
1
38
Ove
Ove
3
8
3
Overall Diffuser = 11 3
4 x 11 4
T-Bar Module = 12 x 12
T-Bar Module = 24 x 24
Plenum
Earthquake Tab
2 - Concealed Hinges
1
4
3
8
2 14
T-Bar Module = 24 x 24
2 Concealed Hinges
Nominal Round
Neck O.D. - 1
8
Earthquake Tab
Return - Round Neck - Face Mounted - T-bar Lay-in - 12" x 12"2 Concealed Hinges
Model 7500R-8
- Steel backpan & face
3
8
Removable
Perforated Face
Model 7500R-8 AF - Steel backpan & aluminum
face
3
3
234
Overall Diffuser
= 23 4&x face
Model 7500R-8 AL - Aluminum
backpan
Earthquake Tab
3
Overall Diffuser = 23 3
4 x 234
2 Concealed
Spring Latches
Plenum
2 Concealed
Spring Latches
Plenum
2 Concealed
Spring Latches
PCD
aled Hinges
T-Bar Module = 24 x 24
Nominal Round
Neck O.D. - 1
8
3/2006
Nominal Round
Neck O.D. - 1
8
3/2006
Listed
Size
Neck Size
6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
1000
0.062
1200
0.090
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-3
1-2-4
1-2-4
1-2-5
1-2-5
-
1-2-5
1-2-5
1-3-5
2-3-5
2-3-5
-
2-3-5
2-3-6
2-3-6
3-4-6
3-4-6
<15
2-3-6
2-4-6
3-4-6
3-5-6
3-5-7
17
3-4-6
3-4-7
3-5-7
4-5-7
4-5-7
21
3-4-6
3-5-7
4-5-7
4-5-7
4-5-8
25
4-5-7
4-6-8
4-6-8
5-6-8
5-6-8
31
5-6-8
5-6-9
5-6-9
5-6-9
5-7-9
36
CFM
Pt
Throw
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
6"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
10"
24" x 24"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
12"
Throw
Throw
Throw
100
0.030
120
0.043
135
0.054
105
0.015
140
0.027
175
0.043
210
0.061
245
0.083
60
0.010
80
0.019
100
0.029
120
0.042
135
0.053
105
0.016
140
0.028
175
0.043
210
0.063
245
0.085
165
0023
220
0.041
275
0.064
325
0.090
235
0.025
315
0.044
1-2-5
1-2-5
1-2-5
2-3-6
2-3-6
1-2-4
1-2-4
1-2-4
1-3-5
1-3-5
1-2-5
1-2-5
1-2-6
2-3-6
2-3-7
1-3-6
1-3-6
1-3-7
2-4-8
2-4-8
-
2-3-6
2-3-6
2-4-7
3-4-7
3-4-7
1-2-5
1-3-5
1-3-5
2-3-6
2-3-6
2-3-6
2-3-7
2-4-7
3-5-7
3-5-8
-
3-4-7
3-4-7
3-5-8
4-5-8
4-5-8
<15
2-3-5
2-3-6
2-4-6
3-4-6
3-4-6
<15
3-4-7
3-4-8
3-5-8
4-6-8
4-6-8
<15
3-5-7
3-5-8
4-5-8
4-6-9
4-6-9
20
2-4-6
3-4-7
3-4-7
3-5-7
3-5-7
17
155
0.072
280
0.109
195
0.114
350
0.170
5-7-10
5-7-11
6-8-11
6-8-11
7-8-11
37
6-7-11
6-8-12
7-8-12
7-9-12
7-9-12
43
3-4-6
3-4-7
3-5-7
4-5-7
4-5-7
21
3-5-7
3-5-7
4-5-8
4-5-8
4-6-8
25
4-5-8
4-6-8
5-6-8
5-6-9
5-6-9
31
5-6-8
5-6-9
5-7-9
5-7-9
6-7-10
36
155
0.070
280
0.111
195
0.110
350
0.174
235
0.160
420
0.250
3-5-8
3-5-9
4-6-9
5-6-9
5-7-9
20
4-6-9
4-6-9
4-7-10
5-7-10
5-7-10
25
4-6-9
4-7-10
5-7-10
6-7-10
6-8-11
30
5-7-10
6-8-11
6-8-11
7-8-12
7-8-12
37
6-8-11
7-9-12
7-9-12
7-9-13
8-9-13
43
7-9-13
7-10-14
8-10-14
8-10-14
9-11-15
42
8-10-14
8-11-15
9-11-16
9-11-16
9-12-16
48
380
0.123
435
0.161
545
0.252
655
0.365
2-4-8
2-4-8
2-5-9
4-6-9
4-6-9
<15
3-5-9
3-5-10
3-6-10
5-7-10
5-7-11
15
4-6-10
4-6-11
5-7-11
6-8-11
6-8-11
22
5-7-11
5-7-12
5-8-12
7-9-12
7-9-12
28
5-8-11
5-8-12
6-9-13
7-9-13
7-9-13
33
395
0.070
470
0.099
550
0.135
630
0.177
785
0.275
4-6-11
4-6-12
4-7-12
6-8-12
6-8-13
17
5-7-12
5-7-13
6-8-13
7-9-13
7-10-14
24
6-8-13
6-9-14
7-10-14
8-10-15
8-11-15
31
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-4-8
2-4-9
2-4-10
3-6-11
3-6-11
-
3-6-11
3-6-12
3-7-13
5-8-13
5-8-13
<15
5-7-13
5-7-14
5-8-14
7-10-14
7-10-15
18
6-8-14
6-9-15
7-10-15
8-11-16
8-11-16
27
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-4-10
2-4-10
2-4-11
4-7-13
4-7-13
-
4-6-13
3-7-13
3-8-14
6-9-15
6-9-15
<15
5-8-14
5-8-16
5-9-16
8-11-16
8-11-17
20
420
0.040
420
0.245
4-6-9
4-6-9
5-7-10
6-7-10
6-7-10
30
3-5-10
3-5-10
3-6-11
5-7-11
5-7-11
<15
320
0.033
235
0.165
4-5-8
4-6-9
4-6-9
5-7-9
5-7-9
25
1-3-7
1-3-7
1-3-8
3-5-9
3-5-10
-
CFM
Pt
16"
80
0.019
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
14"
60
0.011
430
0.059
560
0.071
535
0.091
700
0.110
640
0.131
840
0.159
750
0.179
975
0.214
855
0.233
1070
0.365
1115
0.280
1395
0.438
11-14-20
11-16-22
13-16-23
13-16-23
14-17-24
52
PCD
940
0.395
1285
0.527
11-14-20
12-15-21
13-15-22
13-16-22
13-16-23
56
1675
0.631
13-16-22
13-17-24
14-18-25
15-18-25
15-18-26
60
PCD-121
Listed
Size
Neck Size
6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
1000
0.062
1200
0.090
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-2
1-2-4
1-2-4
1-2-5
2-3-5
-
1-2-3
1-3-5
2-3-5
2-3-6
3-4-6
-
1-2-4
2-3-6
2-3-6
3-4-6
3-5-7
-
2-2-4
3-4-7
3-4-7
3-5-7
4-5-7
<15
2-3-4
3-5-7
3-5-7
4-5-7
4-5-8
17
2-3-5
4-5-8
4-5-8
4-6-8
5-6-8
21
3-4-5
4-6-9
4-6-9
5-6-9
5-7-9
28
3-4-6
5-7-10
5-7-10
6-7-10
6-7-10
32
CFM
Pt
Throw
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
PCD
6"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
10"
24" x 24"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
Throw
Throw
Throw
105
0.014
140
0.025
175
0.038
60
0.011
80
0.020
100
0.031
105
0.014
140
0.025
175
0.038
165
0.016
220
0.029
275
0.046
1-2-3
1-2-5
1-3-5
2-3-6
2-4-7
1-1-3
1-2-4
1-2-4
1-3-5
2-3-5
1-2-3
1-2-6
1-3-6
2-3-7
2-4-7
-
1-2-4
2-4-7
2-4-7
3-4-8
3-5-8
1-2-3
2-3-6
2-3-6
2-3-6
3-4-6
1-2-4
2-4-8
2-4-8
3-5-8
3-5-8
-
120
0.045
210
0.055
135
0.057
245
0.075
155
0.075
280
0.098
3-4-6
5-7-11
5-7-11
6-8-11
6-8-11
25
3-5-7
6-8-12
6-8-12
7-9-12
7-9-12
32
4-5-7
7-9-13
7-9-13
8-9-13
8-10-13
36
1-2-4
2-4-7
2-4-7
3-4-7
3-5-7
-
2-3-4
3-4-7
3-4-7
3-5-7
4-5-8
<15
2-3-4
3-5-8
3-5-8
4-6-8
4-6-8
17
2-3-5
4-6-8
4-6-8
4-6-8
5-6-9
21
3-4-5
5-7-9
5-7-9
5-7-9
6-7-10
28
3-4-6
6-7-10
6-7-10
6-7-10
6-8-11
32
4-6-8
8-10-14
8-10-14
8-10-14
8-10-14
36
120
0.045
210
0.055
135
0.057
245
0.075
155
0.075
280
0.098
3-4-6
5-8-11
5-8-11
6-8-11
7-8-12
25
4-5-7
6-9-12
6-9-12
7-9-13
7-9-13
32
4-5-8
6-9-14
6-9-14
7-10-14
8-10-14
28
5-6-9
5-7-10
8-11-16 9-12-17
8-11-16 9-12-17
9-11-16 10-12-17
9-11-16 10-13-18
37
42
325
0.064
380
0.087
435
0.114
3-4-8
5-7-13
5-7-13
6-8-13
7-10-14
<15
3-5-8
6-8-14
6-8-14
7-10-15
8-11-15
17
4-6-9
4-7-10
7-10-16 8-11-17
7-10-16 8-11-17
8-11-16 9-12-17
9-11-16 10-12-17
25
31
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-6
2-4-10
2-5-10
3-6-12
4-7-12
-
3-4-8
3-7-13
4-7-13
5-8-14
6-9-14
-
3-5-9
5-8-15
6-8-15
7-10-16
8-11-16
<15
4-6-10
4-7-11
7-10-17 8-12-18
7-10-17 8-12-18
8-12-17 9-13-19
9-12-18 11-13-19
19
27
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-7
2-5-11
2-5-11
4-7-14
4-8-14
-
3-4-9
4-8-15
4-8-15
6-9-16
7-10-16
-
4-6-10
4-7-11
6-9-18 8-11-19
6-9-18 8-11-19
8-11-18 9-14-20
9-13-18 10-14-20
<15
21
560
0.045
420
0.221
3-4-6
4-7-10
4-7-10
5-8-11
6-8-11
20
2-3-7
3-6-11
3-6-11
5-7-12
5-8-12
-
420
0.025
350
0.153
235
0.172
2-3-6
4-6-10
4-6-10
5-7-10
5-7-10
<15
1-2-5
2-4-8
2-4-8
3-5-10
3-6-11
-
430
0.041
195
0.119
2-3-5
3-5-9
3-5-9
4-6-9
4-6-9
-
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
320
0.023
420
0.221
2-4-6
4-6-10
4-6-10
5-7-10
6-7-10
20
3-5-7
5-8-13
5-8-13
7-9-13
8-10-14
22
315
0.037
350
0.153
235
0.172
2-3-5
4-5-9
4-5-9
4-6-9
5-7-10
<15
3-4-7
5-7-12
5-7-12
6-8-12
6-9-12
16
235
0.021
195
0.119
2-3-5
3-5-8
3-5-8
4-5-9
4-6-9
-
2-3-6
4-6-11
4-6-11
5-7-11
5-8-11
<15
CFM
Pt
16"
100
0.031
2-3-6
2-5-10
3-5-10
4-6-10
4-7-10
-
CFM
Pt
14"
80
0.020
1-2-4
1-3-7
2-3-7
2-4-8
3-5-9
-
CFM
Pt
12"
60
0.011
395
0.059
535
0.063
700
0.070
470
0.083
640
0.091
840
0.100
550
0.113
750
0.124
975
0.135
5-8-12
9-13-21
9-13-21
10-15-21
12-15-22
29
630
0.149
545
0.179
785
0.231
655
0.259
940
0.331
5-8-11
9-13-19
9-13-19
11-13-19
11-14-19
40
7-8-12
11-14-20
11-14-20
12-15-21
12-15-21
43
5-8-11
9-13-19
9-13-19
10-14-20
12-14-20
34
6-9-13
11-15-22
11-15-22
13-16-22
13-16-23
45
8-10-14
13-17-24
13-17-24
14-17-24
14-18-25
50
6-9-13
10-15-22
10-15-22
12-16-23
13-16-23
36
7-10-14
13-18-25
13-18-25
15-18-25
15-18-26
48
9-11-16
15-19-27
15-19-27
16-20-28
16-20-28
54
855
0.162
1115
0.177
1070
0.253
1395
0.276
1285
0.365
1675
0.398
PCD-122
3/2006
3/2006
CFM
10
CFM
12
14
600
-.04
700
-.05
800
-.06
900 1000
-.08 -.10
175
210
245
280
315
390
470
80
105
140
CFM
235
315
CFM
18
500
-.03
CFM
CFM
16
60
400
-.02
CFM
165
320
420
520
220
425
560
700
100
270
535
700
115
325
640
835
135
380
550
750
155
435
630
175
195
490
545
705
350
785
Performance Notes:
All data are tested in accordance with ANSI/ASHRAE 70-1991
Definition of Units:
CFM - Cubic feet per minute (air)
fpm - Velocity of air streem in feet per minute
Pv - Velocity pressure (inches of water column)
Pt - Total pressure (inches of water column)
Ps - Static pressure = Pt - Pv (inches of water column)
Throw* - Non-isothermal horizontal throw (supply air temperature 15F colder than average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
Throw - Isothermal horizontal throw (supply air temperature the same as average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
NC - Noise criterion, sound pressure level. NC ratings are based on sound power level (Lw) RE: 10E-12 watts minus a 10 dB room attenuation in
all octave bands
Ak - Area Factors
PCD
Models 7500R (-1, -6, -8, -9), 7500R AF (-1, -6, -8, -9), 7500R DF (-1), 7500R AL (-6, -8, -9)
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7500-6 AL - T-bar Lay-in
7500-8 AL - Tegular T-bar
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7500R-6 AL - T-bar Lay-in
7500R-8 AL - Tegular T-bar
PCD-123
3/2006
Butterfly Damper
METALAIRE model BDS aluminum round butterfly type dampers shall be provided. Damper shall consist of two butterfly style blades that can be adjusted
from full open to full closed. Damper shall be adjusted with a screw driver slot that can be assessed through the face of the diffuser.
Radial Shutter Damper
METALAIRE model RSD steel round radial shutter damper shall be provided. Damper shall consist of gang operated radial blades that slide perpendicular
to air flow direction. The damper shall be adjusted from full open to full closed. Damper shall be adjusted with a screw driver slot that can be assessed
through the face of the diffuser.
Opposed Blade Damper
METALAIRE model D3 aluminum or SD3 steel round opposed blade type dampers shall be provided. Damper shall consist of gang operated blades that
can be adjusted from full open to full closed. Damper shall be adjusted with a screw driver slot that can be assessed through the face of the diffuser.
Equalizing Grid
METALAIRE model G3 aluminum round equalizing grid shall be provided. Equalizing grid shall consist of 1/2" x 1/2" x 1/2" aluminum cubed core mounting
in an aluminum frame.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
PCD
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
PCD-124
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
6"
Module
Available Finishes
Standard
7500-1
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
01 -White
Steel Face & Backpan
Available Options
8"
10"
12" x 12"
12"
24" x 24"
Optional
14"
16"
28 - Custom Color
Model
7500-6
Available Neck
Available Options
Standard
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
01 -White
6"
8"
10"
12"
14"
16"
Optional
12" x 12"
24" x 24"
28 - Custom Color
Available Finishes
Module
Available Neck
PCD
Model
Available Neck
Module
Available Finishes
Standard
7500R-1
6"
8"
10"
12"
14"
16"
01 -White
Optional
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
12" x 12"
24" x 24"
Available Options
28 - Custom Color
Model
7500R-6
Module
Standard
6"
8"
10"
12"
14"
16"
01 -White
Optional
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
12" x 12"
24" x 24"
28 - Custom Color
Available Finishes
Available Neck
Available Neck
Module
Available Finishes
Standard
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
- Supply
M7500R-6 - Return
6"
8"
10"
12"
14"
16"
Available Options
01 -White
Optional
600 x 600
28 - Custom Color
PCD-125
3/2006
PCD
Product Details
Series 7550 perforated supply diffusers have 4
adjustable pattern controllers mounted on the
face of the diffuser. Pattern controllers are
adjustable from a horizontal to vertical discharge
pattern
Plenum
2 Concealed
Hinges
der 1 DF
onal Drop Face
Plenum
Supply
Border 1
Perforated Face
1
8
3
8
2 Concealed Spring
Latches
Border 1 DF
Optional Drop Face
Pattern Controller
Nominal
1
Square Neck Size - 4
Plenum
1
38
Border 1
Perforated Face
Pattern Controller
3
Ceiling Opening = 23 3
4 x 23 4
3
Overall Diffuser = 25 3
x
25
8
8
Model 7550-1
Standard Finish: 01 White
2 Concealed
Hinges
2 Concealed
Spring Latches
3
8
T-Bar
1
38
3
8
Nominal Square
1
Neck Size - 4
Pattern Controller
3
Overall Diffuser = 23 3
4 x 23 4
2 Concealed
Hinges
Border 1 DF
Optional Drop Face
2 Concealed
1
38
2 Concealed
Hinges
Pattern Controller
2 Concealed
Spring Latches
T-Bar
3
Ceiling Opening
23 3
Adjustable
- T-bar =Lay-in
4 x 23 4
1
38
Perforated Face
2 Concealed
Spring Latches
3
8
Nominal Square
1
Neck Size - 4
Plenum
1
38
2 Concealed
Hinges
T-Bar
Pattern Controller
Perforated Face
2 Concealed
Spring Latches
Perforated Face
3
Ceiling Opening = 23 3
4 x 23 4
T-Bar Module = 24 x 24
Plenum
2 Concealed
Hinges
Nominal Square
1
Neck Size - 4
T-Bar
3
8
2 Concealed
Pattern Controller
3
Overall Diffuser = 23 3
4 x 23 4
Ceiling Grid Module = 24 x 24
Nominal Square
1
Neck Size - 4
2 Concealed
Spring Latches
38Fineline
Donn
Plenum
1
38
Nominal Square
1
Neck Size - 4
Plenum
T-Bar Module = 24 x 24
PCD-126
Nominal Square
1
Neck Size - 4
Perforated Face
lenum
1
38
2 Concealed
Hinges
7550
3 x 23 3
Opening =- 23
Supply - Square Neck Ceiling
- Adjustable
Surface
4
4 Mount
3
Diffuser
= 25 3
Model 7550-1 Overall
- Steel
backpan
face
8 x&25
8
Model 7550-1 DF - Steel backpan & face - drop face
Model 7550-1 AF - Steel backpan & aluminum face
2 Concealed
Hinges
rder 1 DF
tional Drop Face
enum
1
8
3
8
2 Concealed Spring
Latches
Series 7550
Plenum
3
8
2 Concealed
Spring Latches
Donn Fineline1
Pattern Controller
Ove
Ceili
3
8
3/2006
2 Concealed Hinges
1 38
2 Concealed
Spring Latches
Hinged Removable
Perforated Face
Return
Return - Square Neck - Surface Mount
Model 7550R-1
- Steel backpan & face (24" x 24")
Model 7550R-1 DF - Steel backpan & drop face (24" x 24") 1
Neck Size = Listed Size - 4
Model2 7550R-1
AF - Steel backpan & aluminum
face (24"
x 24")
Concealed
Frame
2 Concealed
Spring Latches
Hinges
1
14
2 Concealed Hinges
13
8
Face (Available On 24 x 24
8
1
Neck Size = Listed
Size
- 4Sizes Only)
Nominal
Face
3
3
3
22 3
Frame
4 x 22 4 OR 22 4 x 10 4
3
3
3
Ceiling Opening = 23 3
4 x 23 4 Or 23 4 x 11 4
3 Or 25 3 x 13 3
Overall Diffuser = 25 3 x 25 8
8
8
8
1 38
2 Concealed
Spring Latches
2 Concealed Hinges
13
8
3
3
3
3
Overaall Diffuser = 23 4 x 23 4 Or 23 4 x 11 4
13
8
2 Concealed Hinges
13
8
2 Concealed Hinges
13
8
Spring Latches
Frame
3
22 4 x 22 4 Or 22 4 x 10 4
3
Overall Diffuser
= 23 3
3
3
43xx23
4
Overaall Diffuser = 23 4 x 23 3
Or
23
4
4 11 4
Perforated Face Plate
3
3T-Bar Module
3
3 = 24 x 24
2 Concealed
Spring Latches
3
8
13
8
Frame
13
8
3
8
3
3
3
22 3
4 x 22 4 OR 22 4 x 10 4
3
Optional
3 Drop Face
OR 22 3
8
4 x 10 4
3 Or 23 3 x 11 3
x
23
Overall Diffuser = 23 3
4
4
4 1
3
3 4 3
3
Perforated3Face Plate
3
22
x 22
3
34
3 4
22 3
4 x 22 4 OR 22 4 x 10 4
Overall
Diffuser
Neck
Size ==23Listed
- 44 x 11 4
4 x 23 Size
4 Or 23
2 Concealed Hinges
Frame
3
3
3
22 3
4 x 22 4 Or 22 4 x 10 4
3
3
3
Overall Diffuser = 23 4 x 23 3
4 Or 23 4 x 11 4
1
Neck Size = Listed Size - 4
2 Concealed
13
8
13
8
2 Concealed Hinges
Frame
H
P
Overall D
2 Concealed Hinges
Frame
2 Concealed Hinges
Frame
2C
13
8
Hinged Removable
Perforated Face
Overall Diffuser = 11 3 x 11 3
4
Hinged Removable 4
T-Bar Module
Perforated
Face = 12 x 12
Frame
13
8
3
8
2 Concealed Hinges
13
8
Frame
2 Concealed Spring
2 Concealed3Hinges
2 Conceale
18
3
8
2 Concealed Hinges
Frame
Frame
Hinged Removable
Perforated Face
Overall D
3
Overall Diffuser = 11 3
T-Bar
4 x 11 4
T-Bar
Module
=
12
x
12
Latches
Hinged Removable
Perforated Face
3
Overall Diffuser = 11 3
4 x 11 4
T-Bar Module = 12 x 12
2C
13
8
3
Overall Diffuser = 11 3
4 x 11 4
T-Bar Module = 12 x 12
3
3
3
Overall Diffuser = 23 3
4 x 23 4 Or 23 4 x 11 4
1
Return - Square
Neck - Donn Fineline
Neck Size = Listed Size - 4
13
1 x 24")
8
Model 7550R-9
Steel
backpan
&
face
Neck Size = Listed
Size(24"
-4
3
18
2 Concealed Spring Latches
Frame
2 Concealed Hinges
Model 7550R-9
AF - Steel backpan 2&Concealed
aluminum
face
(24" x 24")
Spring
Latches
2 Concealed Hinges
Hinged Removable
Perforated Face
2 Concealed Hinges
FrameCeiling O
Ceiling Opening 11 3 x 11 3
4
4
Hinged Removable
Perforated Face
Overall Diffuser = 11 3 x 11 3
4
4
T-Bar Module = 12 x 12
22 4 x 22 4 Or 22 4 x 10 4
3
3
3
3
Overaall Diffuser = 23 4 x 23 4 Or 23 4 x 11 4
T-Bar Module = 24 x 24
13
8
Hi
Pe
Frame
2 Concealed Hinges
3
Or 23 3
4 x 11 4
1
Neck Size = Listed Size - 4
2 Concealed
Spring
Latches
2 Concealed
Spring
Latches
Hinged Removable
Frame
2 Concealed
Spring Latches
1
2 Concealed Hinges
Neck Size = Listed Size 2 Concealed
Frame
Frame
2 Concealed Hinges
1
Neck Size = Listed Size - 4
4
Frame
3
8
RemovableFace
HingedPerforated
Perforated Face
Ceiling Opening
11 3 x 11 3
4
Overall Diffuser = 11 3 x 11 34
4
4
T-Bar Module = 12 x 12
2 Concealed Hinges
2 Concealed H
1 38
13
8
Border 1 DF Optional2Drop
Concealed 3
Perforated Face Plate
1
Face
On 24Spring
x 24 Latches8
Neck Size = Listed
Size(Available
- 4
1
14
Nominal Face Sizes Only)
Frame
3
3
3
3
22 4 x 22 4 OR 22 4 x 10 4
3
3 13
3
Ceiling Opening = 23 3
4 x 23 4 Or 23 4 x 11 4 8
3 Or 25 3 x 13 3
Overall DiffuserBorder
= 25 31 xDF
25Optional
Drop
8
8
8
8 3
Perforated Face Plate
2 Concealed
Hinges
13
8
Frame
13
8
PCD
d
hes
13
8
PCD-127
Metric
PCD
Notes for Models 7550 (-1, -6, -8, -9), 7550-1 DF, 7550 AF (-1, -6, -8, -9), 7550 AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
03 Black
22 (BBP) Black back pan/white face
28 Custom color
2. Available Accessories
All accessories shipped unattached
Square Necks:
OBD - Opposed blade damper - Steel . . . . . . .334
OBDA - Opposed blade damper - Aluminum .334
L9 - Equalizing grid . . . . . . . . . . . . . . . . . . . . .334
Round Neck:
G3 - Round Equalizing Grid . . . . . . . . . . . . . .337
BDS - Butterfly damper . . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter damper . . . . . . . . . . . . .336
3. Construction Details
Pattern controllers are mounted on the back
side of the perforated face and can be
adjusted 1, 2, 3 or 4 way pattern
Pattern controller on 12" x 12" unit is a non
adjustable disc on the perforated face
7550 has 3/16" diameter holes on 1/4"
staggered centers
Notes for Models 7550R (-1, -6, -8, -9), 7550R-1 DF, 7550R AF (-1, -6, -8, -9), 7550R AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
28 Custom color
PCD-128
3/2006
2. Available Accessories
All accessories shipped unattached
Square Necks:
OBD - Opposed blade damper - Steel ..............334
OBDA - Opposed blade damper - Aluminum ...334
3. Construction Details
7550R has 3/16" diameter holes on 1/4"
staggered centers
Round Neck:
BDS - Butterfly damper....................................335
RSD - Radial Shutter damper...........................336
3/2006
Listed
Size
Neck Size
6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
1000
0.062
1200
0.090
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-4
1-2-4
1-2-5
1-3-5
2-3-5
-
1-3-5
1-3-5
1-3-6
2-4-6
2-4-6
-
2-3-6
2-3-6
2-4-6
3-5-7
3-5-7
<15
3-4-6
3-4-7
3-5-7
4-5-7
4-5-7
19
3-4-7
3-5-7
4-5-8
4-6-8
4-6-8
25
3-5-7
4-5-8
4-6-8
5-6-8
5-6-9
29
4-6-8
4-6-9
5-6-9
5-7-9
6-7-10
36
5-6-9
5-7-10
6-7-10
6-7-10
6-7-10
41
CFM
Pt
Throw
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
6"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
10"
24 x 24
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
Throw
Throw
Throw
135
0.017
180
0.031
220
0.046
75
0.013
100
0.023
125
0.036
135
0.017
180
0.031
220
0.046
210
0.023
280
0.040
345
0.061
1-2-5
1-2-5
1-2-6
2-4-7
2-4-7
1-2-4
1-2-4
1-2-5
2-3-5
2-3-6
1-3-5
1-2-6
1-2-6
2-4-7
2-4-7
-
2-3-7
2-4-7
2-4-8
3-5-8
3-5-8
1-3-5
1-3-6
1-3-6
3-4-6
3-4-6
2-4-7
2-4-8
2-4-8
3-5-8
3-5-9
-
150
0.052
265
0.067
175
0.071
310
0.092
200
0.093
355
.121
250
0.145
445
0.190
300
0.209
535
0.275
3-4-8
3-4-8
3-5-9
4-6-9
4-6-9
<15
3-5-8
4-5-9
4-6-9
5-7-10
5-7-10
20
4-6-9
4-6-10
5-7-10
6-7-10
6-8-11
27
5-7-10
5-7-11
5-8-11
6-8-11
6-8-11
32
6-8-11
6-8-12
7-9-12
7-9-12
7-9-13
39
7-8-12
7-9-13
8-9-13
8-10-14
8-10-14
45
2-3-6
2-4-7
2-4-7
3-5-7
3-5-7
<15
3-4-7
3-4-7
3-5-7
4-5-8
4-6-8
19
3-5-7
3-5-8
4-6-8
4-6-8
4-6-8
25
4-5-8
4-6-8
4-6-9
5-6-9
5-6-9
29
5-6-9
5-7-9
5-7-10
6-7-10
6-7-10
36
5-7-9
6-7-10
6-7-11
6-8-11
6-8-11
41
6-8-11
6-9-13
7-9-13
8-9-13
8-9-13
39
7-9-13
7-10-14
8-10-14
8-10-14
8-10-15
45
150
0.052
265
0.067
175
0.071
310
0.092
200
0.093
355
0.121
3-4-8
3-5-9
3-5-9
4-6-9
4-6-9
<15
4-5-9
4-6-10
4-6-10
5-7-10
5-7-10
20
4-6-10
4-7-10
5-7-11
6-8-11
6-8-11
27
5-7-10
5-7-11
6-8-11
7-8-12
7-8-12
32
415
0.088
485
0.120
555
0.158
250
0.145
445
0.190
695
0.247
300
0.209
535
0.275
835
0.357
4-6-10
4-6-11
4-7-11
5-8-12
5-8-12
<15
4-7-11
5-7-12
5-8-12
6-9-13
6-9-13
22
5-8-12
5-8-13
6-9-13
7-10-14
7-10-14
29
6-9-13 8-10-14
6-9-14 8-11-16
7-10-14 9-11-16
8-10-15 9-12-16
8-11-15 10-12-17
34
42
9-11-16
9-12-17
10-12-18
10-13-18
11-13-18
47
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-4-8
2-4-8
2-4-10
3-6-11
3-6-11
-
3-5-11
3-6-11
3-6-12
5-8-12
5-8-13
<15
5-7-12
4-7-13
4-8-14
6-10-14
6-10-14
15
5-8-13
6-8-15
6-10-15
8-11-15
8-11-16
23
11-13-19
11-15-21
12-15-21
12-15-21
13-16-22
50
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-4-9
2-4-10
2-4-11
4-7-13
4-7-13
-
3-6-13
3-7-13
3-7-14
6-9-14
6-9-15
<15
5-8-14
5-8-15
5-9-16
7-11-16
7-11-17
16
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-5-11
2-5-11
2-5-13
4-8-14
4-8-15
-
4-7-14
4-7-15
4-9-16
7-10-17
7-10-17
<15
CFM
Pt
16"
125
0.036
3-5-9
2-5-9
2-5-10
4-6-10
4-6-11
-
CFM
Pt
14"
100
0.023
1-3-7
1-3-7
1-3-8
3-5-9
3-5-9
-
CFM
Pt
12"
75
0.013
300
0.023
410
0.023
535
0.026
400
0.040
545
0.041
710
0.046
500
0.063
680
0.064
890
0.073
600
0.090
815
0.092
1065
0.104
700
0.123
800
0.160
1000
0.250
955
0.126
1090
0.164
1360
0.255
1245
0.143
1420
0.186
10-14-21
10-15-22
11-16-23
13-17-23
13-17-24
39
1200
0.360
1635
0.369
10-14-20
11-15-22
12-16-22
13-16-23
14-17-23
46
13-16-22
13-17-24
14-17-25
14-18-25
15-18-26
51
12-16-23
12-18-25
14-18-26
15-18-26
16-19-27
49
14-18-25
15-19-27
16-20-28
17-20-29
17-21-29
53
1780
0.291
PCD
2135
0.419
PCD-129
Listed
Size
Neck Size
6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
1000
0.062
1200
0.090
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
1-2-5
1-2-5
1-3-5
2-3-6
-
1-2-4
2-3-6
2-3-6
2-4-6
3-4-7
-
1-2-4
2-4-7
3-4-7
3-5-7
3-5-7
<15
2-3-4
3-5-8
3-5-8
4-5-8
4-6-8
19
2-3-5
4-5-8
4-5-8
4-6-9
5-6-9
25
2-4-5
4-6-9
4-6-9
5-6-9
5-7-9
29
3-4-6
5-7-10
5-7-10
6-7-10
6-7-10
35
4-4-6
6-8-11
6-8-11
6-8-11
7-8-11
40
CFM
Pt
Throw
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
PCD
6"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
10"
24" x 24"
Throw
Throw
Throw
Throw
180
0.028
75
0.012
100
0.022
135
0.016
180
0.028
210
0.020
280
0.028
1-2-4
1-3-6
1-3-6
2-4-7
2-4-8
1-1-3
1-2-5
1-2-5
2-3-6
2-3-6
1-2-4
1-3-6
1-3-6
2-4-8
2-4-8
-
150
0.048
220
0.042
265
0.061
175
0.066
310
0.084
535
0.249
3-4-6
5-7-11
5-7-11
6-8-11
6-8-12
27
3-5-7
5-8-12
5-8-12
6-9-12
7-9-12
32
4-5-8
7-9-13
7-9-13
8-10-14
8-10-14
39
5-6-8
8-10-15
8-10-15
9-11-15
9-11-15
44
1-2-4
2-3-6
2-3-6
3-4-7
3-4-7
-
2-2-4
3-4-7
3-4-7
3-5-8
4-5-8
<15
2-3-5
3-5-8
3-5-8
4-6-8
4-6-8
19
2-3-5
4-6-9
4-6-9
4-6-9
5-6-9
25
2-4-5
4-6-9
4-6-9
5-7-10
6-7-10
29
3-4-6
5-7-11
5-7-11
6-8-11
6-8-11
35
4-5-7
6-8-12
6-8-12
7-8-12
7-8-12
40
4-6-8
7-10-14
7-10-14
8-10-14
8-10-15
39
5-6-9
9-11-15
9-11-15
9-11-16
9-11-16
44
125
0.034
150
0.048
220
0.042
265
0.061
175
0.066
310
0.084
200
0.086
355
0.110
250
0.134
445
0.172
300
0.194
535
0.249
2-3-5
2-4-9
2-4-9
3-5-9
4-6-9
-
2-3-6
3-5-10
4-5-10
4-6-10
5-7-10
<15
2-4-6
4-6-11
4-6-11
5-8-11
6-8-11
20
3-4-7
5-7-12
5-7-12
6-8-12
7-9-12
27
3-5-7
6-9-13
6-9-13
7-9-13
8-9-13
32
4-5-8
6-9-15
6-9-15
7-11-15
9-11-15
30
4-6-9
5-7-10
6-8-11
7-11-16 9-12-18 11-14-19
7-11-16 9-12-18 11-14-19
8-11-16 10-13-18 11-14-20
9-12-16 11-13-18 12-14-20
35
42
46
220
0.042
265
0.061
310
0.084
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-6
2-4-10
2-5-10
3-6-11
4-7-12
-
2-4-7
3-6-13
4-6-13
5-8-14
6-9-14
<15
3-5-9
5-8-15
5-8-15
6-10-15
7-11-15
15
4-6-9
4-7-10
6-10-16 7-11-18
6-10-16 7-11-18
8-11-17 9-13-18
9-12-17 10-13-18
24
31
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-7
2-5-11
2-5-11
4-7-13
4-8-14
-
3-4-9
4-7-15
4-7-15
6-9-16
7-10-16
<15
4-5-10
4-6-11
6-9-17 7-11-19
6-9-17 7-11-19
7-11-18 9-13-19
9-13-18 10-14-20
17
26
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-4-7
2-6-13
3-6-13
4-8-15
5-9-16
-
3-5-10
4-6-11
4-9-17 7-11-20
5-9-17 7-11-20
7-10-18 8-13-20
8-12-18 10-15-21
<15
18
535
0.024
445
0.172
300
0.194
2-4-6
4-6-10
4-6-10
5-7-10
6-8-11
20
3-5-8
5-8-14
5-8-14
6-9-14
7-10-14
23
410
0.023
355
0.110
250
0.134
2-3-5
3-5-9
3-5-9
4-6-10
5-7-10
<15
3-4-7
4-7-12
4-7-12
5-8-13
6-9-13
<15
300
0.021
200
0.086
2-2-5
2-4-8
2-4-8
3-5-9
4-6-9
-
2-3-6
3-5-11
3-5-11
4-6-11
5-7-12
-
CFM
Pt
16"
135
0.016
125
0.034
1-2-5
2-4-8
2-4-8
3-5-10
3-6-10
-
CFM
Pt
14"
100
0.022
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
12"
75
0.012
400
0.037
545
0.040
710
0.043
500
0.058
600
0.083
680
0.062
890
0.067
815
0.089
1065
0.096
5-7-13
9-13-22
9-13-22
10-15-22
12-16-23
28
700
0.113
355
0.110
800
0.147
445
0.172
1000
0.230
535
0.249
1200
0.331
5-7-11
9-13-19
9-13-19
10-14-19
11-14-20
37
6-9-12
11-15-21
11-15-21
12-15-21
13-15-22
44
7-9-13
13-16-23
13-16-23
14-17-24
14-17-24
50
5-8-12
9-13-21
9-13-21
10-15-21
12-15-21
34
6-9-13
10-15-22
10-15-22
12-16-22
13-16-23
40
7-10-14
12-17-25
12-17-25
14-18-25
15-18-26
48
9-11-16
15-19-27
15-19-27
16-19-27
16-20-28
53
6-9-14
10-15-23
10-15-23
12-17-24
14-17-24
36
7-10-14
11-17-25
11-17-25
13-18-26
15-18-26
42
8-11-16
14-20-28
14-20-28
17-20-29
17-21-29
51
10-13-18
17-22-31
17-22-31
18-22-31
18-23-32
56
955
0.122
1245
0.132
1090
0.159
1420
0.171
1360
0.248
1780
0.269
1635
0.358
2135
0.387
PCD-130
3/2006
3/2006
10" x 10"
CFM
8" x 8"
12" x 12"
14" x 14"
16" x 16"
22" x 22"
75
100
120
210
275
345
CFM
130
CFM
300
CFM
CFM
CFM
410
530
175
400
545
710
220
500
680
700
800
900 1000
-.05
-.06
-.08
-.09
265
310
350
400
445
150
415
600
815
175
485
700
200
555
800
225
625
250
695
900 1000
Performance Notes:
All data are tested in accordance with ANSI/ASHRAE 70-1991
Definition of Units:
CFM - Cubic Feet per Minute (air)
fpm - Velocity of air streem in Feet Per Minute
Pv - Velocity pressure (inches of water column)
Pt - Total pressure (inches of water column)
Ps - Static pressure = Pt - Pv (inches of water column)
Throw* - Non-isothermal horizontal throw (supply air temperature 15F colder than average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
Throw - Isothermal horizontal throw (supply air temperature the same as average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
NC - Noise criterion, sound pressure level. NC ratings are based on sound power level (Lw) RE: 10E-12 watts minus a 10 dB room attenuation in all
octave bands
6" x 6"
600
-.03
PCD
PCD-131
3/2006
Supply - Perforated Diffuser - Face Mounted Adjustable Pattern Controller - Square Necks/Series 7550
Steel
7550-1
7550-1 DF
7550-6
7550-8
7550-9
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7550-6 AL - T-bar Lay-in
7550-8 AL - Tegular T-bar
Air Outlets shall be steel model 7550 or aluminum face, steel backpan model 7550-AF or all aluminum model 7550-AL manufactured by METALAIRE.
Units shall consist of aluminum 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. The perforated face shall be
hinged allowing access to four adjustable pattern controllers mounted onto the inside face of the outlet. Face shall be secured in place with tension spring
clips. Pattern controller blades shall be individually adjustable and allow the discharge pattern to be adjustable from vertical to horizontal.
Outlets shall be field adjustable allowing 1, 2 way opposite, 2 way corner, 3, and 4 way directional air patterns.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
PCD
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7550R-6 AL - T-bar Lay-in
7550R-8 AL - Tegular T-bar
Air inlets shall be steel model 7550R or aluminum face, steel backpan model 7550R-AF or all aluminum model 7550R-AL manufactured by METALAIRE.
Units shall consist of aluminum 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. Units shall be designed for
use in ducted return or exhaust applications.
The perforated face shall be hinged allowing access to the inside of the packpan. Face shall be secured in place with tension spring clips.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
PCD-132
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Available Finishes
Standard
7500-1
Model
6" x 6"
8" x 8"
10" x 10"
12" x 12"
14" x 14"
15" x 15"
16" x 16"
18" x 18"
Available Neck
01 - White
Optional
12" x 12"
24" x 24"
- Tegular T-bar
6" x 6"
8" x 8"
10" x 10"
12" x 12"
14" x 14"
15" x 15"
16" x 16"
Model
Module
01 - White
Optional
12" x 12"
24" x 24"
Available Options
OBD
OBDA
L9
Equalizing Grid
OBD
OBDA
L9
Equalizing Grid
03 - Black
22 - Black Back pan White Face
28 - Custom Color
Available Neck
Module
6" x 6"
8" x 8"
10" x 10"
12" x 12"
14" x 14"
15" x 15"
16" x 16"
Available Finishes
Available Neck
01 - White
Optional
12" x 12"
24" x 24"
6" x 6"
8" x 8"
10" x 10"
12" x 12"
14" x 14"
15" x 15"
16" x 16"
Available Options
03 - Black
22 - Black Back pan White Face
28 - Custom Color
Module
- T-bar Lay-in
7550R-9
Equalizing Grid
Available Finishes
Available Finishes
Standard
7500R-8
L9
Standard
7550R-6
- Donn Fineline
Model
7500R-1
OBDA
28 - Custom Color
- T-bar Lay-in
03 - Black
Standard
7500-6
Available Options
OBD
Available Neck
PCD
Model
01 - White
Optional
12" x 12"
24" x 24"
Available Options
OBD
OBDA
L9
Equalizing Grid
03 - Black
22 - Black Back pan White Face
28 - Custom Color
- Donn Fineline
- Supply
M7550R-6 - Return
Available Neck
Module
Available Finishes
Standard
6" x 6"
8" x 8"
10" x 10"
12" x 12"
14" x 14"
15" x 15"
16" x 16"
01 -White
Optional
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
600mm x 600mm
03 - Black
22 - Black Back pan White Face
28 - Custom Color
PCD-133
3/2006
Product Details
The 7600 perforated supply diffuser has curved
blade pattern controllers mounted in the neck of
the diffuser. Pattern controllers are adjustable
from a horizontal to vertical discharge pattern
PCD
D. - 81
Nominal
Round Neck O.D. - 81
Earthquake Tab
Plenum
Nominal
1
Round Neck O.D. - 8
Earthquake Tab
Plenum
8 Latches
2 Concealed
Latches
31
8
Supply
- Round Neck - Border
Neck
Mounted - Adjustable
- Surface Mount
Border 1DF
3
1
1 3
8
Optional Drop Face
8 8 7600-1
Fully Adjustable
And Reversible
backpan & face Hinged, Removable
Model
- Steel
Perforated Face
Curved Blade Air Pattern
Model 7600-1 AF - Steel backpan
& aluminum
3 face
Ceiling Opening 23 3
x
23
4
4
3 face
Model 7600-1 DF - Steel backpan
& face
- drop
Overall Diffuser
= 253
8 x 258
Nominal
Round Neck O.D. - 81
Earthquake Tab
Plenum
2 Concealed
1
38
Latches
Border 1DF
Optional Drop Face
able Perforated Face
3
8
Plenum
Nominal
1
Round Neck O.D. - 8
2 Concealed
Latches
31
8
3
8
2 Concealed
Latches
Earthquake Tab
Plenum
1
38
2 Concealed
Latches
3
8
PCD-134
31 2 Concealed
8
Latches
Plenum
3
Overall Diffuser = 23 3
4 x 23 4
8,
Fully
3 Adjustable And Reversible
Curved
8 Blade Air Pattern Controller
Overall Diffuse
Donn Fineline M
Nominal
Earthquake Tab
Plenum
Nom
Round Ne
Earthquake Tab
1
38
Nominal
1
Round Neck O.D. - 8
Ov
T-Bar Module = 24 x 24
4 x 24
3
Overall Diffuser = 233
4 x 234
3
33
4 x 234
Hinged, Removable
Perforated Face
Nominal
31
8
Earthquake Tab
Plenum
Nominal
1
Round Neck O.D. - 8
T-Bar Mod
T-Bar Module = 24 x 24
Overall Diffus
3
Overall Diffuser = 23 3
4 x 23 4
3
Ceiling Opening 23 3
4 x 23 4
Earthquake Tab
Plenum
2 Concealed
Hinges
31
3
Overall Diffuser = 253
8 x 258
1
.D. - 8
Earthquake Tab
Border 1DF
Optional Drop Face
Hinged, Removable Perforated Face
Border 1
Fully Adjustable And Reversible
Curved Blade Air Pattern
1
8
No
Round N
Earthquake Tab
Plenum
Border 1DF
Optional Drop Face
Hinged, Removable Perforated Face
3 x 23 3
4
4
3
53
8 x 258
7600
Earthquake Tab
Plenum
1
38
8,
1
2 - Concealed
Hinges
8
Border 1
Perforated Face
1
O.D. - 8
Plenum
Earthquake Tab
1
38
1
8
Plenum
Border 1
Perforated Face
1
38
Earthquake Tab
2 - Concealed Hinges
1
8
Overall Diffuser = 25 3 x 25 3
8
8
3
8
Plenum
T-Bar Module = 24 x 24
1
38
Plenum
Perforated Face
Earthquake Tab
2 - Concealed Hinges
2 Concealed Spring Latches
1
38
Perforated Face
Plenum
1
38
Earthquake Tab
2 - Concealed Hinges
Concealed
Perforated Face
Plenum
Earthquake Tab
2 - Concealed Hinges
Ceiling Opening 11 34 x 11 34
T-Bar Module = 12 x 12
Plenum
Earthquake Tab
2 Concealed Hinges
2 41
1
4
2 Concealed Hinges
Ceiling Opening 11 34
No
T-Bar Module = 12
3
8
O.D. - 81
Return - Round
Neck - Tegular T-bar - 12" x 12"
2 41
Model 7600R-8
- Steel backpan & face
Hinged, Removable
Face
Model 7600R-8 AF - Perforated
Steel backpan
& aluminum face
Ceiling Opening 11 34 x 11 34
Model 7600R-8 AL - Aluminum
backpan & face
Plenum
Earthquake Tab
2 Concealed Hinges
Earthquake Tab
Plenum
Earthquake Tab
Plenum 31
8
1
38
2
Concealed Hinges
Concealed
Plenum
2 Concealed Hinges
3
8
Spring Latches
3
8
2 Concealed Hinges
3
8
3
Return - Round Neck - Donn
Fineline
x 24"
Overall Diffuser
= 23 3 x-2324"
4
4
Module
=&
24Neck
x 24
Model 7600R-9
- SteelT-Bar
backpan
face
Nominal
Round
1
O.D. - &
Earthquake Tab
Model 7600R-9 AF - Steel backpan
8 aluminum face
Ceilin
Removable Perfora
T-B
Tegular T-Bar = 12 x 12
31
8
Concealed
Spring Latches
O.D. - 8
2 Concealed Hinges
3
8
Earthquake Tab
T-Bar Module = 24 x 24
Plenum
Nominal Roun
1
O.D.- 8
Tegular T-Bar = 12 x 12
Plenum
Earthquake Tab
Concealed Hinges
3
Overall Diffuser = 23 3
41x 234
3
8
11 3 x 11 3
4
11 3 x 11 3
4
3
8
Plenum
Earthquake Tab
Concealed Hinges
2 Concealed Hinges
11 3 x 11 3
4
4
Rem
11 3 x 11 3
4
Tegular T-Bar = 12
Nom
Plenum
Earthquake Tab
Concealed Hinges
11 3 x 11 3
4
11 3 x 11
Nominal
Round
Ne
Tegular
T-Bar
1
O.D.- 8
3
8
Tegular T-Bar = 12 x 12
Plenum
Concealed
Spring Latches
2 41
Perforated Face
T-Bar Module = 12 x 12
Earthquake Tab
Concealed
1 3 Spring Latches
38
8
Hinged, Removable
Perforated Face
2 - Concealed Hinges
Earthquake Tab
O.D. - 81
2 41
Earthquake Tab
Plenum
Nominal
N
T-BarRound
Module
T-Bar Module = 12 x 12
2 Concealed Hinges
O.D.
Ceiling Opening
2 Concealed Hinges
Hinged, Removable
Perforated Face
Nominal Rou
Hinged, Removable
Perforated Face
Plenum
Earthquake Tab
Ceiling Opening 11 34 x 11 34
Plenum
Over
Hinged, Removable
Perforated Face
Hinged, Removable
Perforated Face
O.D. - 81
Earthquake Tab
Ceilin
Plenum
T-Bar Module = 24 x 24
Hinged, Remov
Perforated Fac
O.D. - 81
Plenum
2 - Concealed Hinges
Ceiling Opening 11 3
4
Overall Diffuser 13 3
8
1
24
Border 1 DF
Optional Drop Face
T-Bar Module = 12 x 12
Earthquake Tab
3
8
Tegu
Tegular T-Bar = 12 x 12
3
8
Module Size = 24 x 24
Earthquake Tab
Plenum
Concealed
2 Concealed
Spring Latches
31
8
3
8
Spring Latches
Earthquake Tab
Plenum
3
8
Hinged,
Removable
1 - Concealed
Perforated
Clip
Spring Face
Ceiling Opening 11 34 x 11 34
Spring Latches
Return
- Round Neck - Tegular
T-bar
- 24"3 x 24"
Overall Diffuser
= 23 3
4 x 23 4
Model 7600R-8
- SteelT-Bar
backpan
Module =&24face
x 24
Removable Perforated Face
Model 7600R-8 AF - Steel backpan & aluminum
face
3
Overall Diffuser = 23 4 x 233
4
Model 7600R-8 AL - Aluminum
backpan
&
face
T-Bar Module = 24 x 24
1
38
1
24
3
Ceiling Opening 11 3
4 x 11 4
Overall Diffuser 13 3 x 13 3
8
8
2 - Concealed Hinges
Ceiling Round
Opening
Nominal
N
O. Diffuser
D. - 1
Overall
8
1 - Concealed
Spring Clip
2 41
Return
- Round Neck - T-bar Lay-in - 24" x 24"
2 - Concealed Hinges
faceNeck
Model 7600R-6
- Steel backpan
Nominal&
Round
1
-8
Model 7600R-6 AF - Steel backpanO.&D.aluminum
face
Model 7600R-6
Aluminum backpan & face
2 ConcealedAL
Spring- Latches
Hinged, Removable
Perforated Face
2 - Concealed Hinges
Hinged, Removable
Perforated Face
3
Overall Diffuser = 23 3
4 x 23 4
Plenum
Earthquake Tab
2 - Concealed Hinges
Plenum
Earthquake Tab
1
24
3
8
Earthquake Tab
1 - Concealed
Spring Clip
3
8
O. D.
1
24
4
4
Overall Diffuser 13 3 x 13 3
8
8
2 - Concealed Hinges
Perforated Face
Plenum
Earthquake Tab
Plenum
Optional
Drop Face
( Border
1 DF ) Tab
Earthquake
3
Ceiling Opening = 23 3
4 x 23 4
Overall Diffuser = 25 3 x 25 3
8
8
3
Ceiling Opening = 23 3
4 x 23 4
2 Concealed Spring Latches
Overall Diffuser = 25 3 x 25 3
8
8
1
38
3
8
Nominal Rou
1 - Concealed
Spring Clip
Plenum
Earthquake Tab
Return - Round
Neck - Surface Mount - 12" x 12"
1
24
Model 7600R-1
- Steel backpan & face
Border 1 DF
Model 7600R-1 AF - Hinged,
Steel Removable
backpan & aluminum
face
Perforated Face
Optional Drop Face
Model 7600R-1 AL - Aluminum
backpan
&
face
Ceiling Opening 11 3 x 11 3
2 - Concealed Hinges
Border 1
Perforated Face
2 - Concealed Hinges
3
Ceiling Opening 11 3
4 x 11 4
Overall Diffuser 13 3 x 13 3
8
8
Border 1 DF
Optional Drop Face
3
Ceiling Opening 11 3
4 x 11 4
Nominal
Round13Neck
3 x 13 3
Overall
Diffuser
8
8
O. D. - 1
8
1 - Concealed
Spring Clip
Plenum
Border 1 D
Optional D
Perforated Face
Hinged, Removable
Perforated Face
1
38
Return
- Round Neck - Surface Mount - 24" x 24"
Model 7600R-1
- Steel backpan & face
1
2 - Concealed
Hinges
Optional Drop Face
8
Model
7600R-1 Border
DF -1 Steel
Perforated
Face backpan & face - drop face
( Border 1 DF )
Nominal Round Neck
3
Ceiling Opening
= 23 3
1 aluminum
Model
7600R-1 AF - Steel backpan
4 x 23 4 face
O.D. -&
3
8
Hinged, Removable
2 - Concealed Hinges
1
24
3
8
3
Ceiling Opening = 23 3
4 x 23 4
Overall Diffuser = 25 3 x 25 3
8 Neck
8
Nominal Round
Return
Earthquake Tab
1
Plenum
24
Earthquake Tab
3
8
Earthquake Tab
Earthquake Tab
1 - Concealed
Spring Clip
1 - Concealed
Spring Clip
Plenum
PCD
1
38
Plenum
PCD-135
PCD
Notes for Models 7600 (-1, -6, -8, -9) 7600-1 DF, 7600 AF (-1, -6, -8, -9) 7600 AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face
28 Custom color
2. Available Accessories
All accessories shipped unattached
Round Neck:
G3 - Equalizing grid . . . . . . . . . . . . . . . .337
BDS - Butterfly damper . . . . . . . . . . . . .335
RSD - Radial Shutter damper . . . . . . . . .336
3. Construction Details
Pattern controllers are mounted on the back
side of the perforated face and can be
adjusted to 1, 2, 3 or 4 way pattern
Seismic tabs standard on all units
7600 has 3/16" diameter holes in
1/4" centers
Notes for Models 7600R (-1, -6, -8, -9), 7600R-1 DF, 7600R AF (-1, -6, -8, -9) 7600R AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face
28 Custom color
PCD-136
3/2006
2. Available Accessories
Round Neck:
BDS - Butterfly damper . . . . . . . . . . . . .335
RSD - Radial Shutter damper . . . . . . . . .336
3. Construction Details
Seismic tabs standard on all units
7600R has 3/16" diameter holes in
1/4" centers
3/2006
6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-2
1-2-4
2-2-5
2-3-5
4-6-9
-
1-2-3
2-3-5
2-3-6
2-3-6
5-7-10
-
1-2-4
2-4-6
3-4-7
3-4-7
7-8-11
<15
2-2-5
3-4-6
3-5-7
3-5-8
7-9-12
19
2-3-5
3-5-7
4-5-8
4-6-8
8-9-13
23
2-3-6
4-5-7
4-6-8
4-6-9
8-10-14
26
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-3
2-3-6
2-3-6
2-3-7
5-8-12
-
1-2-4
3-4-7
3-4-8
3-5-9
7-9-13
-
2-3-5
3-5-8
3-5-9
4-6-10
9-11-15
<15
2-3-6
2-4-7
3-4-8
3-5-8
4-6-9
4-6-9
4-7-9
5-7-10
6-8-11
7-9-12
4-6-9
5-7-10
6-8-11
7-9-12 8-9-13
5-7-11
5-8-11
6-9-12 8-10-14 9-11-15
9-12-16 10-12-18 11-13-19 12-15-21 13-16-23
19
24
27
31
37
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-2
1-2-5
2-3-5
2-3-5
4-6-9
-
1-2-3
2-3-6
2-3-6
2-4-7
6-8-11
-
1-2-4
3-4-6
3-4-7
3-5-8
7-8-12
<15
2-2-5
3-5-7
3-5-7
4-5-8
8-9-13
19
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-3
2-3-6
2-3-7
2-4-7
5-8-12
-
1-2-4
3-4-7
3-4-8
3-5-9
7-10-14
-
2-3-5
2-3-7
3-4-7
3-4-8
4-5-9
4-7-10
3-5-8
4-6-9
5-7-10 5-7-10 7-8-12 7-9-13
4-5-9
4-7-10
5-8-11
6-8-11
7-9-13 8-10-14
4-6-10
5-7-11
6-8-12 6-9-13 8-10-14 9-11-16
9-11-16 10-12-17 11-13-19 11-14-20 13-16-22 14-17-24
<15
19
24
27
31
37
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-4
2-4-8
3-4-8
3-4-9
7-10-15
-
2-3-5
2-3-7
3-4-8
3-5-9
4-5-10
3-5-9
4-6-10
5-7-11
6-9-12 7-9-13
4-6-10
5-7-11
5-8-12 6-9-13 7-10-14
4-6-11
5-7-13 6-9-14 7-10-15 8-11-16
9-12-18 11-14-20 12-15-21 13-16-23 14-18-25
<15
20
25
29
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-2-5
2-3-7
3-4-8
3-5-10
4-6-11
3-5-9
4-6-11
5-8-12 6-9-13 7-10-15
3-5-10 4-7-12 5-8-14 7-10-15 8-11-16
4-5-11
5-7-14 6-9-15 7-11-17 8-12-18
8-12-18 11-15-21 14-17-24 15-18-26 16-20-28
<15
15
22
27
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-6
3-4-8
3-5-10
4-6-11
3-5-11
5-7-13 6-9-14 7-11-16
4-6-11
5-8-14 6-10-16 8-11-17
4-6-12 6-8-16 7-10-18 8-12-19
9-14-21 13-17-25 16-19-27 17-21-30
<15
16
24
CFM
Pt
Throw
CFM
Pt
8"
Throw
CFM
Pt
6"
Throw
CFM
Pt
8"
Throw
CFM
Pt
10"
24" x 24"
Throw
CFM
Pt
12"
Throw
CFM
Pt
14"
Throw
CFM
Pt
16"
Throw
60
0.015
105
0.016
60
0.015
105
0.016
165
0.017
80
0.026
140
0.028
80
0.026
140
0.028
175
0.044
100
0.041
175
0.044
120
0.060
210
0.063
120
0.060
210
0.063
135
0.075
245
0.086
135
0.075
2-3-6
3-5-7
4-6-8
4-6-9
8-10-14
23
245
0.086
155
0.099
280
0.112
195
0.157
235
0.229
280
0.112
350
0.175
420
0.252
545
0.186
655
0.268
2-3-6
3-4-7
3-5-7
4-5-8
5-6-9
6-7-10
4-6-9
5-7-10 6-7-10
5-7-10
6-8-11
7-8-12
9-10-15 10-12-17 11-13-18
26
30
35
435
0.118
315
0.033
395
0.052
470
0.074
550
0.101
630
0.133
320
0.017
430
0.031
535
0.048
640
0.068
750
0.094
420
0.019
560
0.033
700
0.052
840
0.075
4-7-13
8-12-18
9-13-20
9-14-22
20-24-34
25
3-4-6
3-5-7
5-6-8
5-6-9
5-6-9
6-7-10
6-7-10
6-8-11
9-11-16 10-12-17
30
35
155
0.099
380
0.090
4-5-11
7-10-16
7-11-18
8-12-20
18-22-31
17
235
0.229
420
0.252
325
0.066
4*-Way
2-3-7
3-4-9
4-Way
4-6-12 5-8-15
3-Way
4-7-13 6-9-16
2-Way
5-7-14 6-9-18
1-Way 10-16-24 15-20-28
NC
<15
195
0.157
1200
0.090
350
0.175
275
0.047
235
0.018
220
0.030
100
0.041
1000
0.062
5-7-11
8-10-15
9-11-16
10-13-18
16-20-28
34
5-8-12
9-11-16
10-12-18
11-14-20
18-21-30
39
4-7-12
8-11-16
9-12-17
9-14-19
17-21-30
31
5-8-13
10-12-17
11-14-19
12-15-21
19-24-33
36
7-10-15
11-13-19
12-15-21
14-17-23
21-26-36
42
4-7-13
8-12-17
9-13-19
10-15-21
19-23-33
29
5-8-14
9-13-18
10-14-20
11-16-22
20-25-35
33
6-10-16
12-14-20
13-16-22
14-18-25
22-27-39
38
8-11-17
13-16-22
14-17-25
16-19-27
25-30-43
44
5-8-15
9-14-19
10-15-21
11-17-24
21-26-37
30
6-9-16
11-15-21
12-16-23
13-18-26
23-28-40
34
7-11-18
13-16-23
15-18-26
16-20-29
26-31-44
39
9-13-20
15-18-25
16-20-28
18-22-31
28-34-49
46
975
0.101
855
0.122
1115
0.132
785
0.206
1070
0.191
1395
0.206
Listed
Size
PCD
940
0.295
1285
0.276
1675
0.297
PCD-137
Listed
Size
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
1000
0.062
1200
0.090
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
1-2-3
1-2-4
3-4-6
3-5-7
-
1-2-3
1-2-4
2-3-4
4-5-7
4-6-8
-
1-2-4
2-3-5
2-3-5
5-6-8
5-6-9
-
2-3-4
2-3-5
3-4-5
5-6-9
6-7-10
<15
2-3-4
2-4-6
3-4-6
5-7-9
6-8-11
17
2-3-4
3-4-6
3-4-6
6-7-10
7-8-11
20
3-3-5
3-5-7
4-5-7
6-8-11
7-9-13
26
3-4-5
4-5-7
4-5-7
7-9-12
8-10-14
32
CFM
Pt
6"
12" x 12"
Throw
CFM
Pt
8"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
PCD
6"
Throw
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
8"
Throw
24" x 24"
Throw
Throw
Throw
Throw
210
0.063
135
0.075
245
0.086
155
0.099
280
0.112
195
0.157
350
0.175
235
0.229
420
0.252
1-2-3
1-2-4
1-3-5
4-5-8
4-7-9
-
1-2-4
2-3-6
2-4-6
5-7-10
6-8-11
-
2-3-5
2-4-6
3-4-6
6-8-11
7-9-12
<15
2-3-5
3-4-7
4-5-7
7-8-12
8-9-13
15
3-4-6
3-5-8
4-5-8
7-9-13
8-10-14
19
3-4-6
4-5-7
4-5-7
4-6-8
5-6-9
6-7-10
5-6-8
5-6-9
6-7-10
8-10-13 9-11-15 10-12-17
9-11-15 10-12-17 11-13-19
22
28
34
1-1-3
1-2-3
1-2-4
3-4-7
4-5-7
-
1-2-3
1-2-5
2-3-5
4-5-8
5-6-9
-
1-2-4
2-3-5
2-4-5
5-6-8
6-7-10
-
2-3-4
2-3-6
3-4-6
5-7-9
6-7-11
<15
2-3-4
3-4-6
3-4-6
6-7-10
6-8-11
17
2-3-5
3-4-6
4-4-6
6-7-11
7-8-12
20
2-3-5
3-4-7
4-5-7
7-9-12
8-10-14
15
3-4-6
3-5-8
4-6-8
8-9-13
9-11-15
19
3-4-6
4-5-7
4-5-8
4-6-9
5-7-10 6-7-10
5-6-9
5-7-10 6-7-10
8-10-14 9-11-16 10-12-17
9-11-16 10-13-18 11-14-20
22
28
34
60
0.015
105
0.016
80
0.026
140
0.028
100
0.041
175
0.044
120
0.060
210
0.063
135
0.075
245
0.086
155
0.099
280
0.112
195
0.157
3-4-5
4-5-7
4-5-7
7-8-12
8-9-13
26
350
0.175
235
0.229
3-4-6
4-6-8
5-6-8
8-9-13
9-10-15
32
420
0.252
2-3-5
2-4-7
3-5-7
6-8-11
7-9-13
<15
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-4
1-3-6
2-4-7
5-7-11
6-9-12
-
2-3-5
2-4-7
3-5-8
6-9-13
8-10-14
-
2-4-6
3-4-7
3-5-7
4-5-8
5-6-9
5-7-9
3-5-8
4-6-9
4-6-10
5-7-11
6-8-12 7-9-13
4-6-8
5-6-9
5-7-10
6-8-11
7-8-12 8-9-13
8-10-14 9-11-15 10-12-17 10-13-18 11-14-20 13-15-22
9-11-16 10-12-17 11-13-19 12-14-20 13-16-22 14-17-25
<15
16
21
24
31
38
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-3-5
1-3-7
2-4-8
6-8-13
7-10-15
-
2-3-7
3-4-7
3-5-8
4-6-9
5-7-9
6-7-10
3-4-9
4-6-10
4-7-11
5-8-12 6-9-13 7-10-14
4-6-9
5-7-10
6-8-11
7-8-12 7-9-13 8-10-14
8-11-15 9-12-17 11-13-18 11-14-20 12-15-21 14-17-24
9-12-17 11-14-19 12-15-21 13-16-23 14-17-24 16-19-27
<15
17
22
25
32
7-8-11
9-11-16
9-11-16
15-18-26
17-21-29
40
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-6
3-4-8
3-5-9
4-6-9
5-7-10
5-8-11
7-9-12
2-4-8
3-5-10 4-6-12 5-8-13 6-9-14 7-10-15 9-12-17
2-5-9
4-7-11
5-8-12 7-9-13 8-10-14 9-11-15 10-12-17
7-10-15 9-12-18 11-14-20 12-15-21 13-16-23 14-18-25 16-20-28
8-12-17 11-14-20 13-16-22 14-17-24 15-19-26 16-20-28 18-22-31
<15
18
23
27
34
8-9-13
10-13-18
11-13-18
18-22-30
20-24-34
43
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-7
3-5-9
4-6-10
5-7-11
5-8-12 6-9-12
2-4-9
3-6-12 5-7-13 6-9-15 7-10-16 8-12-17
3-6-10 5-7-12 6-9-13 7-10-15 9-11-16 10-12-17
8-11-17 10-14-20 13-16-22 14-17-25 15-19-26 16-20-28
9-14-20 12-16-23 15-18-25 16-20-28 17-21-30 19-23-32
<15
20
24
29
9-11-15
12-15-21
12-15-21
20-25-35
23-28-39
45
CFM
Pt
16"
175
0.044
120
0.060
2-2-4
2-3-6
2-4-6
5-7-10
6-8-11
-
CFM
Pt
14"
140
0.028
100
0.041
1-2-3
1-2-4
1-3-5
4-6-9
5-7-10
-
CFM
Pt
12"
105
0.016
80
0.026
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
10"
60
0.015
165
0.017
235
0.018
320
0.017
420
0.019
220
0.030
315
0.033
275
0.047
325
0.066
380
0.090
435
0.118
545
0.186
655
0.268
940
0.295
395
0.052
470
0.074
550
0.101
630
0.133
785
0.206
430
0.031
535
0.048
640
0.068
750
0.094
855
0.122
1070
0.191
560
0.033
700
0.052
840
0.075
975
0.101
1115
0.132
1395
0.206
8-10-14
10-13-19
11-13-19
18-22-32
21-25-36
36
1285
0.276
1675
0.297
PCD-138
3/2006
3/2006
CFM
10
CFM
12
14
600
-.04
700
-.05
800
-.06
900 1000
-.08 -.10
175
210
245
280
315
390
470
80
105
140
CFM
235
315
CFM
18
500
-.03
CFM
CFM
16
60
400
-.02
CFM
165
320
420
520
220
425
560
700
100
270
535
700
115
325
640
835
135
380
550
750
155
435
630
175
195
490
545
705
350
785
Performance Notes:
All data are tested in accordance with ANSI/ASHRAE 70-1991
Definition of Units:
CFM - Cubic feet per minute (air)
fpm - Velocity of air streem in feet per minute
Pv - Velocity pressure (inches of water column)
Pt - Total pressure (inches of water column)
Ps - Static pressure = Pt - Pv (inches of water column)
Throw* - Non-isothermal horizontal throw (supply air temperature 15F colder than average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
Throw - Isothermal horizontal throw (supply air temperature the same as average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
NC - Noise criterion, sound pressure level. NC ratings are based on sound power level (Lw) RE: 10E-12 watts minus a 10 dB room attenuation in
all octave bands
PCD
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7600-6 AL - T-bar Lay-in
7600-6 AL - Tegular T-bar
Air Outlets shall be steel model 7600 or aluminum face, steel backpan model 7600-AF or all aluminum model 7600-AL manufactured by METALAIRE.
Units shall consist of a 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. The perforated face shall be
removable allowing access to aluminum curved blade pattern with tension spring clips. Pattern controller blades shall be individually adjustable and allow
the discharge pattern to be adjustable from vertical to horizontal. Pattern controller blades shall pivot in adjustable from vertical to horizontal. Pattern
controller blades shall pivot in friction mounting retainers. Retainers shall hold the deflector blade position throughout the specified operating range of the
device. Metal friction wires are not acceptable.
Outlets shall be available in 1, 2-way opposite, 2-way corner, 3, and 4-way directional air patterns.
Return - Perforated Diffuser - Round Neck - 12" x 12"/24" x 24" Module/Series 7600
Steel
7600R-1
7600R-1 DF
7600R-6
7600R-8
7600R-9
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7600R-6 AL - T-bar Lay-in
7600R-6 AL - Tegular T-bar
Air Inlets shall be steel model 7600R or aluminum face, steel backpan model 7600R-AF or all aluminum model 7600R-AL manufactured by METALAIRE.
Units shall consist of aluminum 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. Units shall be designed for
use in ducted return or exhaust applications.
The perforated face shall be hinged allowing access to the inside of the packpan. Face shall be secured in place with tension spring clips.
The units shall be the size and quality as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling systems.
PCD-139
3/2006
PCD
Equalizing Grid
METALAIRE model G3 aluminum round equalizing grid shall be provided. Equalizing grid shall consist of 1/2" x 1/2" x 1/2" aluminum cubed core mounting
in an aluminum frame
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
.8-1.0 mils
Film Cure
PCD-140
Performance
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Module
Air Pattern
Available Finishes
Standard
Standard
4W - 4-way
6"
Available Options
01 - White
Optional
Optional
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
8"
7600-1
1W - 1 Way
03 - Black
2W - 2-Way Opposite
2C - 2 Way Corner
28 - Custom Color
24" x 24"
D3
12"
7600-1 AF - Flush Surface Mount - Aluminum Face
Damper - Aluminum
14"
16"
3W - 3-Way
Model
7600-6
Available Neck
Module
Air Pattern
Available Finishes
Standard
Standard
4W - 4-way
- T-bar Lay-in
6"
01 - White
Optional
Available Options
Optional
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
PCD
Model
8"
7600-6 AL - T-bar Lay-in - All Aluminum
1W - 1 Way
10"
7600-8
- Tegular T-bar
03 - Black
24" x 24"
12"
2W - 2-Way Opposite
2C - 2 Way Corner
28 - Custom Color
16"
7600-9
Aluminum
SD3
- Donn Fineline
Steel
3W - 3-Way
ST - Star Corner Blow
Available Neck
Module
Available Finishes
Available Options
Standard
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
6"
01 - White
8"
7600R-1
12" x 12"
12"
24" x 24"
Optional
28 - Custom Color
Model
7600R-6
Available Neck
Module
Available Finishes
Standard
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
- T-bar Lay-in
6"
01 - White
10"
12" x 12"
12"
24" x 24"
Optional
- Tegular T-bar
- Donn Fineline
28 - Custom Color
Available Neck
Module
Available Finishes
Standard
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
03 - Black
D3
SD3
- Supply
M7600R-6 - Return
Available Options
6"
01 -White
8"
Optional
10"
600 x 600
12"
14"
16"
28 - Custom Color
PCD-141
3/2006
PCD
Square
1
4
Plenum
Nominal
1
Supply - Square Neck -AdjustableSquare
- T-bar
Neck Size Lay-in
-4
Model 7650-6 2 Concealed
- Steel
backpan & face
Spring Latches
Model 7650-6
AF - Steel backpan & aluminum face
31/8
Border 1DF
Optional Drop Face
Model 7650-6 AL - Aluminum backpan & face
Nominal
1
Square Neck Size
1 -4
3
8
3
Overall Diffuser = 25 3
8 x 25 8
3
Hinged, Removable
Perforated Face
Border 1DF
Optional Drop Face
Nominal
1
4
Border 1
3
4
3
8
2 Concealed Hinges
3
Overall Diffuser = 23 3
4 x 23 4
2 Concealed Hinges
PCD-142
1
38
T-Bar Module = 24 x 24
Hinged, Removable
Perforated Face
T-Bar Module = 24 x 24
Square
Plenum
3
Overall Diffuser = 23 3
4 x 23 4
Module Size = 24 x 24
Plenum
2 Concealed Hinges
Nominal
1
Square Neck Size - 4
Hinged, Removable
Perforated Face
3
Overall Diffuser = 23 3
4 x 23 4
2 Concealed Hinges
3
Overall Diffuser = 23 3
4 x 23 4
Nominal
T-Bar Module = 24 x 24
Hinged, Removable
Perforated Face
Nominal
1
Square Neck Size - 4
3
Overall Diffuser = 23 3
4 x 23 4
2 Concealed Hinges
T-Bar Module = 24 x 24
1
1
38
Hinged, Removable
Perforated Face
Plenum
3
Overall Diffuser = 23 3
4 x 23 4
T-Bar Module = 24 x 24
T-Bar Mo
2 Concealed Hinges
3
4
PlenumLatches
2 Concealed Spring
1
38
Overall Diffu
2 Concealed Hinges
Hinged, Removable
Perforated Face
Nominal
1
Square Neck Size - 4
1
Square Neck Size - 4
1
Square Neck Size - 4
Plenum
31/8
Nominal
Nominal
Plenum
Border 1DF
Optional Drop Face
g Latches
31/8
3
8
Hinged, Removable
Perforated Face
3
Ceiling Opening = 23 3
4 x 23 4
3
Overall Diffuser = 25 3
8 x 25 8
Border 1DF
Optional Drop Face
T-Bar Module = 24 x 24
Nominal
1
Square Neck Size - 4
Plenum
3
Overall Diffuser = 23 3
4 x 23 4
8
2 Concealed
Hinges
3
8
Plenum
Hinged, Removable
Perforated Face
3
Ceiling Opening = 23 3
4 x 23 4
3
Overall Diffuser = 25 3
8 x 25 8
31
Dimensions
31/8 are in inches
2 Concealed Hinges
1
8
nged, Removable
rforated Face
Plenum
e And Reversible
Pattern Controller
7650
g Latches
Series 7600
Product Details
The 7650 perforated supply diffuser has curved
blade pattern controllers mounted in the neck of
the diffuser. Pattern controllers are adjustable
from a horizontal to vertical discharge pattern
1
38
Overall Diffu
Nominal
1
Square Neck Size - 4
Plenum
Overall Diffuser = 23 3 x 23 3
4
Hinged, Removable Pe
3
Overall Diffuser = 23 3
4 x 23 4
Module
Size = 24 x 24
2 Concealed Spring
Latc
3 x 12, 14 x 14 and 16 x 16
Available Neck Sizes (For All Models): 6 x 6, 8 x 8, 10 x 10, 12
Fully Adjustable And Reversible
Curved Blade Air Pattern Controller
Module S
13
Frame
Return - Square
Neck - Adjustable - Surface Mount
8
2 Concealed
Model 7650R-1 2 Concealed
- SteelHinges
backpan & face
(24" xSpring
24")Latches
Model 7650R-1 DF 2-Concealed
Steel
backpan
(24" x 24")
Hinges
Perforated
Face Plate& drop face -Frame
3 Or 22 3 x 10 3
22 3 x 22 4 &
Model 7650R-1 AF - Steel backpan
aluminum
face (24" x 24")
4
4
4
13
8
13
8
2 Concealed
Spring Latches
Overaall Diffuser = 23 3 x 23 3 Or 23 3 x 11 3
4
4
4
4
Hinged
Removable
Available For 24
x 24 And
24 x 12 T-Bar Lay-In Ceiling Grids.
1
Size
= Listed
Size
24 x 24Neck
Return
Available
With
22- x 422 Neck Size.
Perforated
Face
24 x 12 Return Available With 22 x 10 Neck
3 Size Only.
3
2 Concealed Hinges
Ceiling Opening 11 4 x 11 4
2 Concealed Hinges
13
8
2 Concealed Hinges
Frame
Frame
2 Concealed Hinges
13
8
3
8
Perforated Face
3
11 3
4 x 11 4
2 Concealed
T-Bar Module = 12 x 12
2 Concealed Hinges
13
8
3
18
1
Neck Size = Listed Size - 4
Overall
Diffuser = Module Size - 4
Hinged
Removable
Module Size
Perforated Face
3
3
11 4 x 11 4
T-Bar Module = 12 x 12
1
4
Frame
3
18
Perforated Face Plate
3
8
Frame
Frame
3
8
Module Size
Frame
Frame
13
8
2 Concealed Hinges
Perforated Face
3
11 3
4 x 11 4
T-Bar Module = 12 x 12
Frame
13
2 Concealed Hinges
3
8
13
8 Available For 24 x 24 And 24 x 12 T-Bar Lay-In Ceiling Grids.
1
Neck Size = Listed Size - 4
Hinged Removable
Perforated Face
3
3
Neck11Size
= Listed
Size - 1
4
4 x 11
4
T-Bar Module = 12 x 12
Module Size
2 Concealed Hinges
Frame
= Module Size
- 14 Latches
2 Concealed Hinges Overall Diffuser
2 Concealed
Spring
Module Size
2 Concealed Hinges
13
8
3
8
2 Concealed Hinges
Frame
13
8
13
8
Frame
Spring Latches
2 Concealed
Spring Latches
Available Hinged
For 24Removable
x 24 And 24 x 12 T-Bar Lay-In Ceiling Grids.
Perforated
Face With 22 x 22 Neck Size.
24 x 24 Return
Available
3 x 11 3
Ceiling Available
Opening 11With
24 x 12 Return
4 224 x 10 Neck Size Only.
2 Concealed Hinges
Frame
13
8
Spring Latches
Hinged Removable
Perforated Face
3
Ceiling Opening 11 3 x 11
4
4
2 Removable
Concealed
Hinged
Frame
13
8
Frame
Perforated Face
Return - Square Neck - Adjustable
- Surface Mount
11 3 x 11 3
4
4
Perforated Face Plate
Model 7650R-1
- 3Steel backpan
& face
x 12")
T-Bar Module
= 12 x(12"
12
3
3
22 4 x 22 4 Or 22 4 x 10 3
4 - drop face (12" x 12")
Model 7650R-1 DF - Steel backpan & face
3
3
3
3
Overaall
= 23
23 4 x 11 4face (12" x 12")
Model 7650R-1
AF Diffuser
- Steel
backpan
4 x 23 4&Oraluminum
2 Concealed
HingesSize - 1
Neck
Size = Listed
4
Return
3
18
PCD
3/2006
Overall Diffuser
= Module Size - 4
2 Concealed
Hinges
Module Size
Frame
Hinged Removable
Perforated Face
3
3
11 4 x 11 4
T-Bar Module = 12 x 12
PCD-143
Metric
PCD
Notes for Models 7650 (-1, -6, -8, -9), 7650-1 DF, 7650 AF (-1, -6, -8, -9), 7650 AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face
28 Custom color
2. Available Accessories
All accessories shipped unattached
Square Necks:
OBD - Opposed blade damper - Steel . . . . . . .334
OBDA - Opposed blade damper - Aluminum .334
L9 - Equalizing grid . . . . . . . . . . . . . . . . . . . . .334
3. Construction Details
Pattern controllers are mounted on the back
side of the perforated face and can be
specified for 1, 2, 3 or 4 way pattern
Series 7650 have 3/16" diameters holes on
1/4" staggered centers
Round Neck:
G3 - Round equalizing grid . . . . . . . . . . . . . . .337
BDS - Butterfly damper . . . . . . . . . . . . . . . . . .335
RSD - Radial Shutter damper . . . . . . . . . . . . .336
Notes for Models 7650R (-1, -6, -8, -9), 7650R-1 DF, 7650R AF (-1, -6, -8, -9), 7650R AL (-6, -8)
1. Available Finishes
Standard Finish:
01 White
Optional Finish
02 Aluminum paint
03 Black
22 (BBP) Black back pan/white face
28 Custom color
PCD-144
3/2006
2. Available Accessories
All accessories shipped unattached
OBD - Opposed blade damper - Steel . . . . . . .334
OBDA - Opposed blade damper - Aluminum .334
3. Construction Details
Available only in listed sizes
Series 7650R have 3/16" diameters holes on
1/4" staggered centers
3/2006
6" x 6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
1-2-5
2-3-5
2-3-6
4-7-10
-
1-2-3
2-3-6
2-4-7
3-4-7
6-8-11
-
1-2-4
3-4-7
3-4-7
3-5-8
7-9-13
<15
2-3-5
3-5-7
4-5-8
4-6-9
8-10-14
16
2-3-6
4-6-8
4-6-9
4-7-10
9-11-15
21
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
2-3-5
2-3-6
2-3-6
4-7-10
-
1-2-4
2-3-6
2-4-7
3-4-8
6-8-12
-
2-2-5
3-4-7
3-5-8
3-5-9
8-9-13
<15
2-3-6
3-5-8
4-6-8
4-6-9
8-10-15
16
2-3-6
2-4-7
3-5-8
4-6-8
4-6-8
5-6-9
6-7-10
6-8-11
4-6-9
5-7-10
6-8-11
7-8-12
5-7-10
5-8-11
7-9-12 8-9-13
9-11-16 10-12-17 11-13-19 12-15-21
21
25
30
36
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
2-3-5
2-3-6
2-3-6
4-7-10
-
1-2-4
2-3-6
2-4-7
3-4-8
6-8-12
-
2-2-5
3-4-7
3-5-8
3-5-9
8-9-13
<15
2-3-6
3-5-8
4-6-8
4-6-9
8-10-15
16
2-3-6
2-4-7
3-5-8
4-6-8
4-6-8
5-6-9
6-7-10
6-8-11
4-6-9
5-7-10
6-8-11
7-8-12
5-7-10
5-8-11
7-9-12 8-9-13
9-11-16 10-12-17 11-13-19 12-15-21
21
25
30
36
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-4
2-3-7
2-4-7
3-4-8
6-9-14
-
2-2-5
2-3-6
2-4-7
3-4-8
3-5-9
4-6-10
3-5-8
4-6-9
5-7-10
5-8-11
6-8-12 8-9-13
3-5-9
4-6-10
5-7-11
6-9-12 7-9-13 8-10-14
4-5-10
4-7-11
5-8-12 6-9-13 7-10-14 9-11-16
8-11-16 10-12-18 11-14-19 12-15-21 13-16-22 14-18-25
<15
18
23
28
34
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-2-5
2-3-6
3-4-8
3-5-9
4-5-11
3-4-9
4-6-10 5-7-12 6-8-13 7-10-14
3-5-9
4-6-11
5-8-13 6-9-14 7-11-15
3-5-10 4-7-13 6-8-14 7-10-16 8-12-17
7-12-17 10-14-20 13-16-22 14-17-24 15-18-26
<15
20
26
4-6-11
8-10-15
8-11-16
9-13-18
16-20-28
29
5-8-13
9-12-16
10-13-18
11-14-20
18-22-31
36
6-9-14
10-13-18
11-14-20
13-16-22
20-24-34
42
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-6
2-4-7
3-5-9
4-6-11
3-5-10 5-7-12 6-9-14 7-10-15
4-6-11
5-7-14 6-9-15 7-11-17
4-6-12 5-8-15 7-10-17 8-12-19
9-14-21 12-17-24 15-19-27 17-21-29
<15
21
4-6-13
8-12-16
9-13-18
9-14-20
18-22-31
26
5-7-14
9-12-18
10-14-19
11-15-22
19-24-34
31
6-9-15
11-14-20
12-15-22
13-17-24
22-27-38
38
7-11-17
12-15-22
14-17-24
15-19-26
24-29-41
44
CFM
Pt
Throw
CFM
Pt
8" x 8"
Throw
CFM
Pt
6" x 6"
Throw
CFM
Pt
8" x 8"
Throw
CFM
Pt
10" x 10"
24" x 24"
Throw
CFM
Pt
12" x 12"
Throw
CFM
Pt
14" x 14"
Throw
Throw
135
0.020
75
0.017
135
0.020
210
0.023
100
0.031
180
0.036
100
0.031
180
0.036
125
0.048
220
0.054
125
0.048
220
0.054
150
0.070
265
0.079
150
0.070
265
0.079
175
0.095
310
0.108
200
0.124
1000
0.040
250
0.194
1200
0.090
300
0.279
2-3-6
3-4-7
3-5-8
4-6-8
5-7-9
6-7-10
5-7-9
6-7-10
7-8-11
5-7-10
6-8-11
7-9-13
9-11-16 10-13-18 11-14-20
25
30
36
355
0.141
445
0.222
535
0.321
175
0.095
200
0.124
250
0.194
300
0.279
310
0.108
355
0.141
445
0.222
535
0.321
555
0.159
695
0.249
280
0.040
345
0.061
415
0.089
485
0.089
300
0.023
400
0.040
500
0.063
600
0.090
700
0.123
410
0.023
545
0.040
680
0.062
815
0.089
535
0.027
710
0.047
4*-Way
2-3-6
3-4-9
4-Way
4-6-12 5-8-15
3-Way
4-7-13 6-9-16
2-Way
5-7-14 6-9-18
1-Way 10-16-24 14-20-28
NC
-
950
0.121
800
0.160
1090
0.159
1000
0.250
1360
0.248
5-7-11
8-10-14
9-11-16
10-12-18
16-19-27
40
835
0.359
1200
0.360
1630
0.356
4-5-11
7-10-16
7-11-18
8-12-20
18-22-31
<15
4-6-13
8-12-18
9-13-20
9-14-22
20-24-34
21
5-7-15
9-14-19
10-15-21
11-16-24
21-26-37
28
6-9-16
11-15-21
12-16-23
12-18-25
23-28-39
33
7-11-18
13-16-23
14-18-25
16-20-28
25-31-44
41
9-13-19
15-18-25
16-20-28
18-22-31
28-34-48
49
4*-Way
2-4-7
3-5-10 4-6-12
4-Way
4-7-14 6-9-17 8-11-19
3-Way
5-7-15 7-10-18 8-12-20
2-Way
5-8-16 7-11-20 9-13-23
1-Way 12-18-27 16-22-32 20-25-35
NC
15
5-7-15
9-14-20
10-15-22
11-16-25
22-27-39
23
6-9-17
11-16-22
12-17-24
12-19-27
24-30-42
30
7-10-18
12-17-23
13-18-26
14-20-29
26-32-45
35
8-12-20
15-19-26
16-20-29
18-23-32
29-35-50
42
10-15-22
17-20-29
18-22-32
20-25-35
32-39-55
50
CFM
Pt
16" x 16"
75
0.017
800
0.040
890
0.074
1070
0.108
1245
0.146
1425
0.191
1780
0.298
Listed
Size
PCD
2135
0.428
PCD-145
Listed
Size
Neck Size
6" x 6"
12" x 12"
300
0.006
400
0.010
500
0.016
600
0.022
700
0.031
800
0.040
1000
0.040
1200
0.090
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
1-2-4
1-2-4
3-5-7
4-6-8
-
1-2-4
1-2-5
2-3-5
4-6-8
5-6-9
<15
2-2-4
2-3-5
3-4-5
5-6-9
6-7-10
16
2-3-4
2-4-6
3-4-6
6-7-10
6-8-11
23
2-3-5
3-4-6
4-5-6
6-8-11
7-9-12
27
2-4-5
3-5-7
4-5-7
7-8-11
7-9-13
30
3-4-6
4-5-8
4-5-8
7-9-13
8-10-14
34
4-4-6
5-6-8
5-6-8
8-10-14
9-11-16
38
CFM
Pt
Throw
CFM
Pt
8" x 8"
Throw
PCD
Throw
Throw
24" x 24"
Throw
Throw
Throw
Throw
355
0.141
250
0.191
445
0.222
300
0.275
535
0.321
3-4-6
3-5-7
4-5-7
5-6-8
4-6-9
4-6-9
5-7-10
6-8-11
5-6-9
5-6-9
6-7-10
6-8-11
8-10-14 9-11-15 10-12-17 11-13-19
9-11-16 10-12-17 11-14-19 12-15-21
30
34
38
41
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-1-3
1-2-4
1-2-4
3-5-7
4-6-8
-
1-2-4
1-3-5
2-3-5
4-6-8
5-7-10
<15
2-2-4
2-3-6
3-4-6
5-7-9
6-8-11
16
2-3-5
3-4-6
3-4-6
6-7-10
7-8-12
23
2-3-5
3-4-7
4-5-7
6-8-11
7-9-13
27
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-4
1-2-5
2-3-6
4-6-10
5-8-11
-
2-3-5
2-3-7
3-4-7
6-8-11
7-9-13
<15
2-3-5
3-4-8
3-5-8
7-9-13
8-10-14
17
3-4-6
3-5-7
3-5-7
4-6-8
5-6-9
3-5-8
4-6-9
4-7-10
6-8-11
7-8-12
4-6-8
5-6-9
6-7-10
6-8-11
7-8-12
8-10-14 9-11-15 9-11-16 10-13-18 11-14-20
9-11-16 10-12-17 10-13-18 12-14-20 13-16-22
25
30
34
38
41
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
1-2-5
1-3-6
2-4-7
5-8-12
7-10-14
-
2-3-6
3-4-7
3-5-8
4-6-8
4-6-9
5-7-10
2-4-8
3-5-9
4-6-10
5-7-11
6-8-12 7-9-13
4-5-9
4-7-9
5-7-10
6-8-11
7-8-12 8-9-13
7-10-14 9-11-16 10-12-17 11-13-19 12-14-20 13-16-22
9-11-16 10-13-18 11-14-20 12-15-21 13-16-23 15-18-25
18
26
32
36
41
6-8-11
8-10-15
8-10-15
14-17-25
16-20-28
44
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-6
3-4-7
3-5-8
4-6-9
5-7-10 5-7-10 7-8-12
2-4-8
3-5-10
4-6-11
5-8-12 6-9-13 7-10-14 8-11-16
2-5-9
4-6-10
5-8-11
6-9-12 7-10-13 8-10-14 9-11-16
6-10-15 8-12-17 11-13-19 12-15-21 13-16-22 14-17-24 15-19-27
8-12-17 10-14-19 12-15-22 14-17-24 15-18-25 16-19-27 18-22-30
21
29
35
39
43
7-9-13
10-12-18
10-12-18
17-21-29
19-24-33
46
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
2-3-7
3-5-9
4-6-10
5-7-11
5-8-11
6-9-12
2-4-9
3-6-12 5-7-13 6-9-15 7-10-16 8-12-17
3-6-10 5-7-12 6-9-13 7-10-15 9-11-16 10-12-17
7-11-17 10-14-20 12-16-22 14-17-24 15-19-26 16-20-28
9-14-19 12-16-22 14-18-25 16-19-27 17-21-30 18-22-32
21
30
37
41
8-10-14
10-13-19
11-13-19
18-22-31
20-25-35
46
9-11-15
12-15-21
12-15-21
20-24-34
22-27-39
49
9-11-16
11-15-21
12-15-21
21-25-36
23-29-41
48
10-12-17
13-17-24
14-17-24
23-28-39
26-31-44
52
CFM
Pt
16" x 16"
310
0.108
200
0.122
2-4-6
3-5-8
4-6-8
8-9-13
9-11-15
25
CFM
Pt
14" x 14"
265
0.079
175
0.093
2-3-5
3-4-7
3-5-7
7-8-12
8-10-14
17
CFM
Pt
12" x 12"
220
0.054
150
0.069
2-3-5
2-3-6
3-4-6
5-8-11
7-9-12
<15
CFM
Pt
10" x 10"
180
0.036
125
0.048
1-2-4
1-2-5
2-3-6
4-6-9
5-8-11
-
CFM
Pt
8" x 8"
135
0.020
100
0.031
4*-Way
4-Way
3-Way
2-Way
1-Way
NC
CFM
Pt
6" x 6"
75
0.017
75
0.017
135
0.020
210
0.023
300
0.023
100
0.031
180
0.036
280
0.040
125
0.048
220
0.054
345
0.061
150
0.069
265
0.079
175
0.093
310
0.108
200
0.122
3-4-5
3-5-7
4-5-7
7-8-12
8-10-14
30
355
0.141
250
0.191
300
0.275
445
0.222
535
0.321
835
0.358
3-4-6
4-5-6
4-6-8
5-6-9
5-6-8
5-6-9
8-9-13 8-10-15
9-11-15 10-12-17
34
38
415
0.089
485
0.121
555
0.158
695
0.248
400
0.040
500
0.063
600
0.090
700
0.123
800
0.160
1000
0.250
410
0.024
545
0.043
680
0.067
815
0.096
955
0.131
1090
0.171
1360
0.266
535
0.027
710
0.047
890
0.074
1065
0.107
1245
0.146
1420
0.190
4*-Way
2-4-8
3-5-10
4-7-11
4-Way
2-5-10 4-7-13 6-8-15
3-Way
3-6-12 6-8-14 7-11-15
2-Way 9-13-20 11-16-23 14-18-25
1-Way 10-16-22 14-18-26 17-20-29
NC
22
5-8-12
7-10-17
8-12-17
16-20-28
18-22-31
31
6-9-13
8-12-18
10-13-18
17-21-30
20-24-34
38
7-10-14
9-13-19
11-14-19
18-23-32
21-26-36
42
1780
0.298
1200
0.360
1635
0.385
2135
0.428
PCD-146
3/2006
3/2006
6" x 6"
CFM
10" x 10"
CFM
8" x 8"
12" x 12"
14" x 14"
120
210
275
345
130
CFM
300
CFM
22" x 22"
100
CFM
CFM
16" x 16"
75
CFM
410
530
175
400
545
710
220
500
680
600
700
800
900 1000
-.03
-.05
-.06
-.08
-.09
265
310
350
400
445
150
415
600
815
175
485
700
200
555
800
225
625
250
695
900 1000
Performance Notes:
All data are tested in accordance with ANSI/ASHRAE 70-1991
Definition of Units:
CFM - Cubic Feet per Minute (air)
fpm - Velocity of air streem in Feet Per Minute
Pv - Velocity pressure (inches of water column)
Pt - Total pressure (inches of water column)
Ps - Static pressure = Pt - Pv (inches of water column)
Throw* - Non-isothermal horizontal throw (supply air temperature 15F colder than average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
Throw - Isothermal horizontal throw (supply air temperature the same as average room air temperature) values are for
150 fpm - 100 fpm - 50 fpm velocities
NC - Noise criterion, sound pressure level. NC ratings are based on sound power level (Lw) RE: 10E-12 watts minus a 10 dB room attenuation in
all octave bands
PCD
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7650-6 AL - T-bar Lay-in
7650-6 AL - Tegular T-bar
Air Outlets shall be steel model 7650 or aluminum face, steel backpan model 7650-AF or all aluminum model 7650-AL manufactured by METALAIRE.
Units shall consist of a 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. The perforated face shall be
removable allowing access to aluminum curved blade pattern controller mounted into the neck of the diffusers. Face shall be secured in place with tension
spring clips. Pattern controller blades shall be individually adjustable and allow the discharge pattern to be adjustable from vertical to horizontal. Pattern
controller blades shall pivot in friction mounting retainers. Retainers shall hold the deflector blade position throughout the specified operating
range of the device. Metal friction wires are not acceptable.
Outlets shall be available in 1, 2 way opposite, 2 way corner, 3, and 4 way directional air patterns.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Aluminum
7650R-6 AL - T-bar Lay-in
7650R-8 AL - Tegular T-bar
Air Inlets shall be steel model 7650R or aluminum face, steel backpan model 7650R-AF or all aluminum model 7650R-AL manufactured by METALAIRE.
Units shall consist of aluminum 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. Units shall be designed for
use in ducted return or exhaust applications.
The perforated face shall be hinged allowing access to the inside of the packpan. Face shall be secured in place with tension spring clips.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
PCD-147
3/2006
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Performance
Film thickness
.8-1.0 mils
PCD
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
Model
Module
Air Pattern
Available Finishes
Standard
6" x 6"
4W - 4-way
8" x 8"
Standard
01 - White
Optional
Optional
Available Options
OBD
OBDA
L9
Equalizing Grid
10" x 10"
7650-1
12" x 12"
1W - 1 Way
03 - Black
14" x 14"
24" x 24"
2W - 2-Way Opposite
2C - 2 Way Corner
28 - Custom Color
3W - 3-Way
18" x 18"
7650-6
- T-bar Lay-in
Available Neck
7650-8
12" x 12"
14" x 14"
15" x 15"
7650-9
16" x 16"
- Donn Fineline
Available Finishes
Standard
Standard
01 - White
Optional
8" x 8"
10" x 10"
Air Pattern
4W - 4-way
6" x 6"
Module
Optional
12" x 12"
1W - 1 Way
03 - Black
24" x 24"
2W - 2-Way Opposite
2C - 2 Way Corner
28 - Custom Color
3W - 3-Way
ST - Star Corner Blow
PCD-148
Available Options
OBD
OBDA
L9
Equalizing Grid
3/2006
Module
Available Finishes
Available Options
Standard
6" x 6"
01 - White
OBD
OBDA
L9
Equalizing Grid
8" x 8"
Optional
10" x 10"
7650R-1
12" x 12"
14" x 14"
24" x 24"
03 - Black
22 - Black Back Pan White Face
15" x 15"
28 - Custom Color
16" x 16"
18" x 18"
Available Neck
Module
Available Finishes
Available Options
Standard
7650R-6
- T-bar Lay-in
01 - White
6" x 6"
8" x 8"
Optional
- Tegular T-bar
OBDA
L9
Equalizing Grid
10" x 10"
12" x 12"
765R0-8
OBD
PCD
Model
12" x 12"
Model
03 - Black
24" x 24"
7650R-8 AF - Tegular T-bar - Aluminum Face
14" x 14"
15" x 15"
7650R-9
16" x 16"
- Donn Fineline
- Supply
M7650R-6 - Return
Available Neck
Module
Available Finishes
Standard
6" x 6"
01 -White
8" x 8"
10" x 10"
12" x 12"
14" x 14"
15" x 15"
16" x 16"
Optional
Available Options
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
600mm x 600mm
03 - Black
22 - Black Back pan White Face
28 - Custom Color
PCD-149
3/2006
PCD
Spring Loaded
Core Latch
(2 Per Core)
Filler
Panel
Low Limit
5
Of Duct 3 16
Product Details
9
2 16
The series 7900 is an aluminum, perforated
Removable Perforated Face
Removable
modular core
diffuser.
Modular coresGasket
can
Modular supply
Core
Ceiling Opening = Overall Face Dimensions - 2
be field adjusted
for2 For1-way,
See Chart Page
Overall Face2-way
Dimensions opposite,
Model 7900-1 (Right) With Filler Panel
Model 7900-1 ( Left ) Without Filler Panel
2-way corner, 3-way, and 4-way
discharge air
patterns
Removable Core
Spring Loaded
Core Latch
(2 Per Core)
Gasket
Low Limit
Of Duct
9
2 16
Removable Core
5
3 16
Ceiling Line
1
Overall Diffuser = T-Bar Spacing - 4
(See Chart On Page 2 For Overall Panel Size)
Hinged, Removable
Perforated Face
Spring Loaded
Core Latch
(2 Per Core)
Removable Core
5
3 16
Ceiling Line
Low Limit
Of Duct
5
2 9
16 3 16
Removable Core
Ceiling Line
3
Overall Diffuser = 23 3
4 x 23 4
Ceiling Line
Spring Loaded
Core Latch
(2 Per Core)
Low Limit
Of Duct
2 9/16
Filler
Panel
3 5
16
Spring Loaded
Core Latch
(2 Per Core)
Filler
Panel
Hinged, Removable
Perforated Face
Removable Core
1
Overall Diffuser = T-Bar Spacing - 4
(See Chart On Page 2 For Overall Panel Size)
PCD-150
Low Limit
Of Duct
9
2 16
Filler
Panel
Low Limit
Of Duct
5
2 9
16 3 16
3
Overall Diffuser = 23 3
4 x 23 4
Filler
Panel
Filler
Panel
Hinged, Removable
Perforated Face
Spring Loaded
Core Latch
(2 Per Core)
4
(See Chart On Page 2 For Overall Panel Size)
Gasket
Hinged, Removable
Perforated Face
Low Limit
5
Of Duct 3 16
9
2 16
Filler
Panel
Low Limit
5
Of Duct 3 16
9
2 16
Ceiling Line
Spring Loaded
Core Latch
(2 Per Core)
Removable
Duct Opening = Listed
SizeCore
3 -1
3 x 23
Neck
Size ==23
Listed
Size
Overall
Diffuser
4
4
4
Ceiling Line
Filler
Panel
Spring Loaded
Core Latch
(2 Per Core)
Hinged, Removable
Perforated Face
Spring Loaded
Core Latch
(2 Per Core)
3
Overall Diffuser = 23 3
4 x 23 4
Low Limit
Of Duct
5
2 9
16 3 16
Filler
Panel
Spring Loaded
Perforated
Modular Core Supply Diffusers - Square Neck
Core Latch
Low Limit
(2 Per Core)
1 or 4 Core
- Surface Mount
Of Duct
Filler
5
2 9
Model 7900-1
Panel
16 3 16
Hinged, Removable
Perforated Face
Spring Loaded
Core Latch
(2 Per Core)
Low Limit
Of Duct
9
2 16
5
3 16
Ceiling Line
3/2006
Filler
Panel
7
16
3 5
16
B
A
Three Way
Four Way
PCD
One Way
B
B
A
1. Available Finishes
Standard Finish:
01 White
Optional Finish
03 Black
22 (BBP) Black back pan/white face and frame
28 Custom color
3. Construction Details
2. Available Accessories
Square Neck:
OBD - Opposed blade damper - Steel ..........................334
OBDA - Opposed blade damper - Aluminum ...............334
L9 - Equalizing grid......................................................334
TR DEEP - Square to round transition - deep ..............338
Round Neck:
G3 - Equalizing grid .....................................................337
BDS - Butterfly damper................................................335
RSD - Radial Shutter damper.......................................336
B
B
A
A
B
B
A
A
B
B
A
PCD-151
PCD
Single
Core
Area
(Sq. Ft)
Ak
Neck
Effective
Outlet Vel
Area
Pt
(Sq. Ft.)
3" X 3"
0.063
0.028
4" X 4"
0.111
0.049
5" X 5"
0.174
0.078
6" X 6"
0.250
0.111
7" X 7"
0.340
0.151
8" X 8"
0.445
0.198
9" X 9"
0.562
0.249
10" X 10"
0.695
0.309
11" X 11"
0.840
0.373
12" X 12"
1.000
0.444
200
310
0.020
300
460
0.045
400
615
0.080
500
770
0.125
600
925
0.180
700
1080
0.245
22
1-3
<20
33
2-6
<20
44
3-9
<20
56
4-12
24
67
5-15
29
78
6-18
34
75
2-8
<20
100
4-12
21
125
6-18
27
150
12-24
33
175
10-28
37
89
2-6
<20
133
4-12
<20
178
6-18
25
222
8-24
30
267
10-30
35
311
12-36
40
CFM
THROW
NC
139
2-6
<20
208
4-14
<20
416
14-40
37
486
16-46
42
CFM
THROW
NC
200
2-8
<20
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
CFM
THROW
NC
13
1-3
<20
35
1-3
<20
50
2-6
<20
68
2-6
<20
112
2-6
<20
168
2-7
<20
19
1-4
<20
52
2-7
<20
102
3-9
<20
169
4-13
<20
252
4-14
<20
300
4-14
20
25
2-6
<20
70
3-9
20
136
5-15
23
225
6-18
25
32
3-9
21
87
5-15
26
170
7-21
28
281
9-27
31
278
6-18
26
347
10-30
32
400
8-22
28
500
12-24
35
336
7-20
27
420
11-27
33
38
4-12
27
104
7-20
31
204
10-27
34
337
12-35
36
504
15-43
38
600
16-46
40
44
5-14
31
122
8-23
36
238
11-33
38
393
14-42
41
588
17-49
43
700
18-52
45
PCD-152
3/2006
3/2006
6" X 6"
0.25
0.162
8" x 8"
0.44
10" x 10"
0.69
12" x 12"
1.00
14" x 14"
1.36
16" x 16"
1.78
18" x 18"
2.25
20" x 20"
2.78
0.288
.0450
0.648
0.880
1.152
1.456
1.800
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
CFM
NC
Throw
300
460
0.045
A
B
50
<20
4-Way
3-Way
2-Way
1-Way
1-3
4-Way
3-Way
2-Way
1-Way
1-3
4-Way
3-Way
2-Way
1-Way
1-3
4-Way
3-Way
2-Way
1-Way
1-4
4-Way
3-Way
2-Way
1-Way
1-4
4-Way
3-Way
2-Way
1-Way
1-5
4-Way
3-Way
2-Way
1-Way
1-6
4-Way
3-Way
2-Way
1-Way
2-6
1-3
400
615
0.080
A
B
75
<20
2-4
2-4
2-6
90
<20
1-4
2-4
2-6
1-3
2-4
2-6
140
<20
1-3
2-4
2-4
2-6
200
<20
1-4
2-6
2-6
2-8
270
<20
1-4
2-6
2-6
2-8
355
<20
1-5
2-7
2-7
2-10
450
<20
1-6
2-8
2-8
2-11
560
<20
2-6
3-8
3-8
4-12
1-4
2-6
2-6
2-8
130
<20
2-6
500
770
0.125
A
B
600
925
0.180
A
B
700
1080
0.245
A
B
2-6
3-9
3-9 4-13
4-13
6-18
220
30
4-12
4-12 6-17
6-17
12-24
265
35
5-15
5-15 7-21
7-21
10-30
500
35
7-20
7-20 10-28
10-28
14-40
600
40
100
21
2-6
3-8
3-8
4-12
175
25
125
27
3-8
4-12
205
<20
3-9
3-9 4-13
4-13
6-18
275
26
4-12
4-12 6-17
6-17
8-24
345
32
2-7
2-7 3-10
3-10
4-14
405
21
4-11
4-11 6-16
6-16
8-22
545
29
6-17
6-17 8-24
8-24
12-34
680
36
3-8
2-7
2-7 310
3-10
4-14
300
20
3-9
3-9 4-13
4-13
6-18
400
28
3-9
3-9 4-13
4-13
6-18
530
22
5-15
5-15 7-21
7-21
10-30
710
30
3-10
3-10 4-14
1-14
6-20
830
24
5-16
5-16 7-23
7-23
10-32
1110
32
3-9
3-9 4-13
4-13
6-18
670
23
3-11
3-11 4-16
4-16
6-22
5-15
5-15 7-21
7-21
10-30
900
31
6-18
6-18 8-25
8-25
12-36
150
33
5-15
5-15 7-21
7-21
10-30
415
37
8-23
8-23 11-32
11-32
16-46
815
41
8-23
8-23 11-32
11-32
16-46
885
37
10-29
10-29 14-41
14-41
20-58
1070
42
9-27
9-27 13-38
13-38
18-54
1385
38
12-35
12-35 17-49
17-49
24-70
1665
44
8-24
8-24 11-34
11-34
16-48
1120
37
9-27
9-27 13-38
13-38
18-54
PCD
11-32
11-32 16-45
16-45
22-64
1345
43
12-36
12-36 17-51
17-51
24-72
PCD-153
3/2006
Supply - Perforated Modular Core - Extruded Aluminum - Square Neck - 1 to 4 Core/Series 7900
Steel
7900-1
7900-6
7900-8
7900-9
Surface Mounted
T-bar Lay-in
Tegular T-bar
Donn Fineline
Air Outlets shall be aluminum model 7900 manufactured by METALAIRE. Units shall consist of an aluminum 51% free area perforated face with 3/16"
diameter perforated holes on 1/4" staggered centers. Border of outlet shall be constructed from an aluminum extrusion.
The perforated face shall be removable allowing access to adjustable modular core pattern controllers mounted onto the inside neck of the outlet. Steel
modular cores deflectors are not acceptable. Face shall be secured in place with tension spring clips. Outlets shall be field adjustable allowing 1, 2 way
opposite, 2 way corner, 3, and 4 way directional air patterns.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
PCD
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Property
Test Method
Film thickness
.8-1.0 mils
Film Cure
PCD-154
Performance
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Available Neck
Module
Air Pattern
Available Finishes
Available Options
Standard
01 - White
OBD
OBDA
03 - Black
L9
Equalizing Grid
TR
28 - Custom Color
TR-Deep
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
D3
SD3
Optional
6" x 6"
8" x 8"
12" x 12"
10" x 10"
24" x 12"
12" x 12"
S1-1- 1 Core
20" x 20"
S4-4- 4-Cores
24" x 24"
16" x 16"
48" x 24"
18" x 18"
20" x 20"
Model
Available Neck
Module
Air Pattern
Available Finishes
Available Options
Standard
01 - White
OBD
OBDA
03 - Black
L9
Equalizing Grid
12" x 12"
TR
24" x 12"
28 - Custom Color
TR-Deep
Optional
6" x 6"
8" x 8"
PCD
Model
10" x 10"
7900-6 - T-bar Lay-in
12" x 12"
S1-1- 1 Core
20" x 20"
S4-4- 4-Cores
24" x 24"
48" x 24"
18" x 18"
20" x 20"
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
D3
SD3
PCD-155
Supply Diffusers Perforated Face Modular Core Square Neck Series 7950
um
el)
Standard Finish: 22 BBP White Perforated Face Black Backpan and Core
PCD
1
= Listed Size - choice
The 7950 is Neck
an Size
excellent
for
4
applications
SpringVAV
Core Latch
(2 Per Core)
Plenum
(Steel)
Removable Core
Dimensions
are in inches
Low Limit
49
16
Of Duct
3 11
16
Low Limit
49
16
Of Duct
3 11
16
Overall Diffuser = 25
x 25
Low Limit
49
16
Of Duct
3 11
16
Hinged, Removable
Perforated Face (Steel)
Plenum
(Steel)
Removable Core
Hinged, Removable
Perforated Face (Steel)
3
8
3
Ceiling Opening = 23 3
4 x 23 4
Overall Diffuser = 25 3 x 25 3
8
8
Low Limit
49
16
Of Duct
3 11
16
Hinged, Removable
Perforated Face (Steel)
3
8
Low Limit
Of Duct
11
316
9
416
Hinged, Removable
Perforated Face (Steel)
3
8
Spring
Core Latch
(2 Per Core)
Low Limit
Of Duct
11
316
3
8
9
416
PCD-156
Low Limit
Of Duct
11
316
9
416
3
Overall Diffuser = 23 3
4 x 23 4
3
Overall Diffuser = 23 3
4 x 23 4
Low Limit
Of Duct
11
316
3
8
Low Limit
9
416
Of Duct
11
316
Removable Core
Hinged, Removab
Perforated Face (Ste
3
8
Plenum
(Steel)
3
Overall Diffuser = 23 3
4 x 23 4
Module Size = 24 x 24
Low Limit
Of Duct
311
16
9
416
Removable Core
Hinged, Rem
Perforated Face
3
8
3
Overall Diffuser = 23 3
4 x 23 4
Duct
Opening
Size
Module
Size==Listed
24 x 24
1
Neck Size = Listed Size - 4
9
416
Hinged, Removable
Perforated Face (Steel)
Removable Core
Plenum
(Steel)
3
Overall Diffuser = 23 3
4 x 23 4
Removable Core
Hinged, Remova
Perforated Face (St
3
8
Removable Core
Hinged, Removable
Perforated Face (Steel)
3
8
3
Overall Diffuser = 23 3
4 x 23 4
Removable Core
Hinged, Removable
Perforated Face (Steel)
Low Limit
9
416
Of Duct
11
316
Removable Core
Plenum
(Steel)
Removable Core
Spring
Core Latch
(2 Per Core)
Removable Core
3
8
eel)
m
)
Product Details
The 7950 is a perforated modular core supply
diffuser with a steel backpan. Modular cores can
be field adjusted for 1, 2-way opposite, 2-way
corner, 3, or 4 way air discharge patterns
el)
m
)
3/2006
3
8
9
416
Removable Core
Hinged, Remo
Perforated Face (S
A
B
3/2006
One Way
Three Way
Four Way
A
B
1. Available Finishes
2. Available Accessories
Standard Finish:
01 White (for 7950-1)
22 (BBP) White perforated face with black backpan and cores
Optional Finish
03 Black
28 Custom color
3. Construction Details
All models for Series 7950 (-1, -6, -8), 7950-1 DF, 7950 AF (-1, -6, -8)
6" X 6"
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
8" x 8"
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
10" x 10"
14" x 14"
16" x 16"
18" x 18"
4-Way
3-Way
2-Way
1-Way
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
4-Way
3-Way
2-Way
1-Way
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
4-Way
3-Way
2-Way
1-Way
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
4-Way
3-Way
2-Way
1-Way
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
20" x 20"
4-Way
3-Way
2-Way
1-Way
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
12" x 12"
4-Way
3-Way
2-Way
1-Way
4-Way
3-Way
2-Way
1-Way
CFM
NC
Pt. Total Pressure (in. w.c)
Throw
4-Way
3-Way
2-Way
1-Way
200
305
50
0.006
1-3
1-3
2-4
2-6
2-4
90
0.012
1-3
1-3
2-4
2-6
2-4
140
0.012
1-3
1-3
2-4
2-6
2-4
200
0.014
1-4
1-4
2-6
2-8
2-6
275
0.014
1-4
1-4
2-6
2-8
2-6
355
0.016
1-5
1-5
2-7
2-10
2-7
450
0.016
1-6
1-6
2-8
2-11
2-8
555
0.016
1-5
1-5
2-7
2-10
2-7
300
460
75
0.016
1-4
B
B
1-4
2-6
2-8
2-6
135
0.025
2-6
2-6
3-8
4-12
2-7
3-8
3-9
4-13
4-13
6-18
275
22
0.019
150
24
0.065
3-9
4-13
4-13
6-18
4-12
4-12 6-17
6-17
12-24
4-12
4-12 6-17
6-17
8-24
5-15
5-15 7-21
7-21
10-30
3-9
225
24
0.069
345
25
0.076
265
30
0.080
415
31
0.110
4-13
4-13
6-18
5-15
5-15 7-21
7-21
10-30
7-20
7-20 10-28
10-28
14-40
2-7
3-10
3-10
4-14
4-11
4-11 6-16
6-16
8-22
6-17
6-17 8-24
8-24
12-34
8-23
8-23 11-32
11-32
16-46
3-9
4-13
4-13
6-18
5-15
5-15 7-21
7-21
10-30
8-24
8-23 11-32
11-32
16-46
11-32
10-29 14-41
14-41
20-58
3-9
5-15
5-15 7-21
7-21
10-30
8-21
8-24 11-34
11-34
16-48
11-32
11-32 16-45
16-45
22-64
4-13
4-13
6-18
675
0.036
3-9
125
20
0.049
600
925
3-9
530
0.034
3-9
3-8
4-12
500
770
310
3-10
4-14
410
0.032
3-9
2-6
175
18
0.042
3-9
300
0.030
2-7
100
0.032
2-6
3-8
205
0.027
2-7
400
615B
400
23
0.054
545
0.057
710
25
0.061
900
26
0.065
500
26
0.085
680
0.009
890
33
0.095
1125
35
0.102
600
32
0.122
815
33
0.129
1065
38
0.137
1350
39
0.149
3-10
3-10 4-14
1-14
6-20
5-16
5-16 7-23
7-23
10-32
9-27
9-27 13-38
13-38
18-54
12-35
12-35 17-49
17-49
24-70
3-9
4-13
4-13
6-18
5-15
5-15 7-21
7-21
10-30
8-24
8-24 11-34
11-34
16-48
11-32
11-32 16-45
16-45
22-64
835
0.038
3-9
1110
27
0.068
1385
37
0.106
PCD
1665
40
0.158
PCD-157
3/2006
Surface Mounted
Surface Mounted-Dropped Face
T-bar Lay-in
Tegular T-bar
Donn Fineline
Air Outlets shall be steel model 7950 or aluminum face, steel backpan model 7950-AF manufactured by METALAIRE.
Units shall consist of aluminum 51% free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. The perforated face shall be
hinged allowing access to four adjustable aluminum modular core pattern controllers mounted into the neck of the outlet. Steel modular cores deflectors
are not acceptable. Face shall be secured in place with tension spring clips. Outlets shall be field adjustable allowing 1, 2-way opposite, 2-way corner, 3,
and 4-way directional air patterns.
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
PCD
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
PCD-158
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Module
Available Finishes
Available Options
Standard
01 -White
Optional
- Surface Mount
OBDA
6" x 6"
03 - Black
L9
Equalizing Grid
8" x 8"
TR
28 - Custom Color
TR-Deep
10" x 10"
12" x 12"
24" x 24"
14" x 14"
16" x 16"
Face
18" x 18"
20" x 20"
Model
Available Neck
Module
- Tegular T-bar
6" x 6"
BDS
Butterfly Damper
RSD
D3
SD3
Available Options
Standard
OBDA
03 - Black
L9
Equalizing Grid
TR
28 - Custom Color
TR-Deep
Optional
- T-bar Lay-in
Equalizing Grid
Available Finishes
01 -White
7950-6
G3
PCD
7950-1
OBD
Model
8" x 8"
10" x 10"
24" x 24"
12" x 12"
14" x 14"
- Donn Fineline
16" x 16"
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
D3
SD3
PCD-159
3/2006
PCD
Frame
3
8
15
15
15
19 15
16 x 19 16 Or 21 16 x 21 16
Frame
3
22 3
4 x 22 4
3
8
2 Concealed
Hinges
15
15
15
19 15
16 x 19 16 OR 21 16 x 21 16
Overall Diffuser = 2
2 Concealed
Frame
Hinges
2 Concealed Spring Latches
3
8
3
22 3
4 x 22 4
3
Overall Diffuser = 23 3
4 x 23 4
3
Overall Diffuser = 25 3
8 x 25 8
3
8
T-Bar Module = 24 x 24
2 Concealed
Hinges
15
15
15
19 15
16 x 19 16 OR 21 16 x 21 16
Frame
13
8
3
22 3
4 x 22 4
Drop Face
3
8
3
Overall Diffuser = 23 3
4 x 23 4
T-Bar Module = 24 x 24
2 Concealed
Hinges
15
16
15
15
15
19 15
16 x 19 16 OR 21 16 x 21 16
Frame
Frame
2 Concealed
Spring Latches
3
1
8
1. Available
Finishes
Drop Face
3
4
3
Standard
Finish:
8
01 White
Optional Finish
02 Aluminum
03 Black
28 Custom color
PCD-160
3
22 3
4 x 22 4
3
Overall Diffuser = 23 3
4 x 23 4
T-Bar Module = 24 x 24
3
22 3
4 x 22 4
15
8
15
8
3
Ceiling Opening 23 3
4 x 23 4
1
14
3
4
15
8
T-Bar Module = 2
2 Concealed
Spring Latches
5
8
15
19 15
16 x 19 16 OR 21
2 Concealed
Hinges
3
Overall Diffuser = 25 3
8 x 25 8
2 Concealed
Frame Hinges
1
3
8
3
Ceiling Opening 23 3
4 x 23 4
1
14
5
6
15
15
15
19 15
16 x 19 16 Or 21 16 x 21 16
2. Available Accessories
Drop Face
3. Construction Details
8
Shipped Unattached
OBD - Opposed Blade Damper (square neck) - Steel . . . . . . .334
OBDA - Opposed Blade Damper (square neck) - Aluminum . .334
15
15
19 15
16 x 19 16 OR 21 16
Optio
3
22 3
4 x 22 4
Overall Diffuser = 23 3
4
T-Bar Module = 24 x
3/2006
22" x 22"
700
800
900
1000
225
250
-.05
-.06
-.08
CFM
130
175
220
265
310
350
400
CFM
300
CFM
16" x 16"
600
-.03
10" x 10"
14" x 14"
500
-.02
CFM
12" x 12"
400
-.015
6" x 6"
8" x 8"
300
-.008
CFM
CFM
CFM
75
210
410
530
1010
100
120
275
345
400
500
545
680
710
885
1345
1680
150
175
415
485
600
815
1060
2015
700
200
555
800
625
695
1000
1600
1770
1090
1225
2350
2690
3025
1415
445
900
950
1240
-.09
1360
3360
Series 7650
7650-1 F - Surface Mounted
7650-6 F - T-bar Lay-in
7650-8 F - Tegular T-bar
Air Inlets shall be steel model 7550 F or 7650 F perforated face filter return diffusers manufactured by METALAIRE. Units shall consist of aluminum 51%
free area perforated face with 3/16" diameter perforated holes on 1/4" staggered centers. Units shall include a hinged face and integral frame designed to
accept a 1" thick filter. Face shall be secured in place with tension spring clips.
PCD
The units shall be the size and quantity as outline in the plans and specifications.
Units shall be designed to integrate into the specified ceiling system.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
Performance
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
PCD-161
Model
Available Neck
Module
Available Finishes
Available Options
Standard
01 - White
7550R-1 F - Surface Mount
24" x 24"
7650R-1F - Surface Mount
OBD
OBDA
20" x 20"
Optional
22" x 22"
03 - Black
28 - Custom Color
Model
Available Neck
Module
22" x 22"
24" x 24"
PCD
PCD-162
Available Options
Standard
01 - White
Available Finishes
Optional
OBD
OBDA
03 - Black
28 - Custom Color
3/2006
LL
S
S
D
D
LINEAR
LINEAR
SLOT DIFFUSERS
SLOT DIFFUSERS
3/2006
Model 6600
Pg. 166
Supply
T-bar Lay-in
Surface Mount
Screw Mounted
Concealed Spline
Drop Face
Narrow Tee
LSD
6600-40-8 25/32
Border
6600-40-9 25/32
Border
Surface Mount
Screw Mounted
Concealed Spline
Drop Face
Narrow Tee
Concealed Mounting Hardware 6600R-12-6 1 1/8 Border 6600R-12-1 1 1/8 Border 6600R-42-7 25/32 Border
No Mounting Hardware
6600R-40-8 25/32
Border
6600R-40-9 25/32
Border
Supply/Return Linear Slot Diffuser for Spiral Pipe - Aluminum - Series 6600SP/6600SPR
Model 6610SP
The series 6600SP is designed to integrate into exposed spiral duct systems
Series 6600SP pattern controllers are fully adjustable and can be set from horizontal to vertical discharge
The series 6600SP operates effectively from minimum to maximum flow making this diffuser an excellent
selection for variable volume systems
Series 6600SPR is designed for return applications. The unit is supplied without pattern controllers to
reduce pressure and noise
Pg. 184
Supply
6610SP-11-1 Screw Mounted 1 1/8 Border
6610SP-12-1 Concealed Mounting
Hardware - 1 1/8 Border
LSD-164
Return
6610SPR-11-1 Screw Mounted 1 1/8 Border
6610SPR-12-1 Concealed
Mounting Hardware - 1 1/8 Border
3/2006
Pg. 190
Non Insulated
T-bar Lay-in
Screw Mounted
Surface Mount
Concealed Spline
Drop Face
Narrow Tee
LSD
Insulated
T-bar Lay-in
Screw Mounted
Surface Mount
Concealed Spline
Drop Face
Narrow Tee
Model BP
The series BP (non-insulated) and BPI (insulated) boot plenums are designed to connect the Series 6600
linear slot diffusers to the ducted supply or return system
Units provide an even distribution of air into the series 6600 diffuser to maximize induction
and occupant comfort
The series BPI boot plenum is fully insulated including the end caps
Units can be used for both ducted and plenum returns
Factory tested and manufactured BP/BPI plenums are built to fit securely into the series 6600 of
diffusers reducing installation cost and minimizing leakage
Available with an optional quadrant locking damper
Series BP & BPI are shipped separate from series 6600 linear slot diffusers and require field attachment
Model L-5000
Surface Mount
T-bar Lay-in
L-5000-1
L-5000-6
Pg. 200
LSD-165
3/2006
LSD
The 6600 is an excellent choice for continuous linear applications such as perimeter office space where the diffuser can direct air along the perimeter wall or
glass and towards the occupied area to maximize comfort. Other applications for the 6600 linear slot diffuser include large public areas that demand superior
comfort such as airport terminals, convention centers, or shopping malls. The flexibility of the 6600 allows the diffuser to be installed in a variety of applications
to maximize occupant comfort.
The Series 6600 pattern controllers can be adjusted from the face to obtain vertical to horizontal throw. Pattern can be field set for left or right horizontal
throw direction. Multiple slot units can be field set for one or two-way opposite horizontal throw.
In the horizontal setting, the diffuser produces a tight air pattern from maximum to minimum flow, making the 6600 an excellent choice for variable volume
systems.
6600 Pattern Controllers can be field- adjusted to vary discharge volume
while maintaining a tight horizontal pattern
LSD-166
A = Nominal Width
3/2006
1 81
1 34
1 81
1 34
4 58
S*
1
18
3
4
Series 6600-10-6
A = Nominal Width
Hanger
Screw
Air Pattern
Controller
Air Pattern
Controller
4 58
Hanger
Screw
Air Pattern
Controller
Series 6600-12-6
W =Overall
Width
T-bar
Lay-in
1 1/8" Border
W =Overall Width
A = Nominal Width
D2 = Duct Opening
A = NominalHanger
Width
Screw
Air Pattern
Controller
D1 = Duct
Opening
A = Nominal
Width
Air Pattern
Controller
A = Nominal Width
1 34
1 81
1
18
S*
Air Pattern
Controller
4 58
1 34
1 81
3
4
Air Pattern
Controller
4 58
S*
1 81
1
3
W1=Overall
Width
4
1 81
W =Overall Width
1
18
S* 3
4
W= Overall Width
End Border
End Cap
T-Bar Module
T-Bar Module
Duct Opening = T-Bar Module - 2 41
Duct Opening = T-Bar Module - 2 41
S* 3
4
W= Overall Width
LSD
1
18
1 81
Hanger
Screw
D1 = Duct Opening
T-Bar Module
T-Bar Module
Duct Opening = T-Bar Module
Duct Opening = T-Bar Module
1
8
1 81
18
Overall Length = T-Bar
Module - 1
Overall Length
= T-Bar Module - 1
4
1 81
T-Bar Module
Duct Opening = T-Bar Module
T-Bar Module
Duct Opening = T-Bar Module1- 2 41
Right
Horizontal
Overall Length
= T-Bar
Module - 1
T-Bar Module
Duct Opening = T-Bar Module
Left Horizontal
Overall Length = T-Bar Module - 1
4
Vertical Projection
18
1
1 81 Model 6650 (6650-10-6 & 6650-12-6)
18
Overall Length = T-Bar Module - 1
Overall
Number
of Air Length
Slots = T-Bar Module - 4
4
5
6
7
8
S = 1"
Slot
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2 12 1/4
9 1/8
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
9 3/8
10 5/8
D2
2 3/8
4 1/8
5 7/8
7 5/8
9 3/8
10 1/4 11 1/2
3 1/4
6 3/4
8 1/2
10 1/4
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 1/4
7 1/2
8 3/4
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
7 7/8
D2
1 7/8
3 1/8
4 3/8
5 5/8
6 7/8
8 1/8
2 3/4
5 1/4
6 1/2
7 3/4
12
14
13 3/4 15 1/2
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8 12 3/8
D2
2 1/8
3 5/8
5 1/8
6 5/8
8 1/8
9 5/8
11 1/8 12 5/8
4 1/2
7 1/2
10 1/2
12
13 1/2
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
For more product information visit us at www.metalaire.com
LSD-167
3/2006
Series 6600-20-6
T-bar Lay-in 3/4" Border
Supply - 3/4" Border - T-bar Lay-in
Model 6650-20-6 - 1/2" Slot Width
Model 6675-20-6 - 3/4" Slot Width
Model 6610-20-6 - 1" Slot Width
D1 = Duct Opening
D1 = Duct Opening A = Nominal Width
Air Pattern
A = Nominal Width
Air Pattern
Controller
Controller
Air Pattern
Controller
A = Nominal Width
S*
3
4
3
4
1 1 W =Overall Width
1 34
1 = Duct Opening
1D1
8
1 34
1 81
3
4
3
4
S*
3
4
W =Overall Width 3
14
S*
3
4
W =Overall Width
End Cap
Model 6600-20-6
Model 6600-20-6
LSD
End Border
T-Bar Module
T-Bar Module
Duct Opening
= T-Bar Module - 1
Duct Opening = T-Bar Module - 1 21
T-Bar Module
T-Bar Module
1
2
T-Bar Module
T-Bar Module
3
4
3
Opening
4
1
2
Duct
= T-Bar Module
-1
3
Overall Length
4 = T-Bar Module Overall Length = T-Bar Module - 41
3
1 4
4
3
1 4
4
Vertical Projection
Right Horizontal
Left Horizontal
Model 6610
Model 6650
Number of Air Slots
S = 1"
Slot
8 3/4
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2 12 1/4
7 7/8
9 1/8
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
8 1/4
9 1/2
10 3/4
2 1/2
4 1/4
7 3/4
9 1/2
11 1/4
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 5/16
7 1/2
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
3 1/4
4 1/2
5 3/4
13
8
14
14 3/4
Model 6675
Number of Air Slots
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8 12 3/8
2 1/4
3 3/4
5 1/4
6 3/4
8 1/4
9 3/4
11 1/4 12 3/4
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
LSD-168
1
4
1
4
3/2006
Series 6600-30-6
T-bar Lay-in 1/2" Border
Supply - 1/2" Border - T-bar Lay-in
Model 6650-30-6 - 1/2" Slot Width
Model 6675-30-6 - 3/4" Slot Width
Model 6610-30-6 - 1" Slot Width
D1 = D uct Opening
D1 = D uct Opening
Air Pattern Air Pattern
= D uct
A =D1Nom
ina lAOpening
W=idth
Nom ina l WController
idthAir Pattern
Controller
A = Nom ina l W idth
Controller
1 81
13
4
1 81
13
4
13
4
1 81
S*
1
11
S*
1
S* 2 2 1
2 1
2
2 =Overall 2
W
Width
W =Overall Width
W =Overall Width
End Cap
Model 6600-30-6
Model 6600-30-6
LSD
End Border
1
2
1
2
1
2
2
1
Overall Length
= T-Bar
Module
- 41 Module
Overall
Length
= T-Bar
2
Overall Length = T-Bar Module - 41
1
1 2
4
Overall Length
= T-Bar
Module
- 41 Module Overall
Length
= T-Bar
Overall Length = T-Bar Module - 41
1
4
Vertical Projection
Right Horizontal
Left Horizontal
Model 6610
Model 6650
Number of Air Slots
S = 1"
Slot
8 3/4
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2 12 1/4
7 7/8
9 1/8
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
7 3/4
10 1/4
3 3/4
5 1/2
7 1/4
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 5/16
7 1/2
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
1 1/2
2 3/4
5 1/4
6 1/2
8
14
Model 6675
Number of Air Slots
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8 12 3/8
1 3/4
3 1/4
4 3/4
6 1/4
7 3/4
9 1/4
10 3/4 12 1/4
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
LSD-169
Series 6600-12-1
A = Nominal Width
Hanger
Screw
D2 = Duct Opening
C
D1 = Duct Opening
Air Pattern
1 34
C
Controller
A = Nominal Width
D1 = Duct Opening
Air Pattern
S* 3 A = Nominal Width
Controller
1
18
4
1 81
3/2006
1 81
S*
1
18
D2 = Duct Opening
Pattern
Air
Hanger
A = Nominal Controller
Width
Screw
45
8
1 34
W =Overall Width
1 81
A = Nominal Width
1 81
4 58
1 34
S*
11 45
8 8
3
4
1 81
S* 3
1 Width
W =Overall
18
4
3
4
C
1 81
11
8
W =Overall Width
W= Overall Width
S* 3
4
S*
Bottom
Hanger
of Hem
Screw
Min = 3/4"
Air Pattern
Max = 1-1/4"
Controller
Bottom
Air Pattern
of Hem
Controller
Bottom of
Bottom
Min
=
3/4"
Ceiling Plane
of Hem
Max = 1-1/4"
Min = 3/4"
Max = 1-1/4"
11
8
W= Overall Width
Bottom of
Ceiling Plane
3
4
Bottom of
Ceiling Plane
LSD
C
W= Overall Width
End Border
Note: For the 6600-12-1, the BP/BPI plenum must be installed with 3/4" minimum/ 1-1/4" Maximum opening between the bottom of the ceiling plane and the bottom of the hem of the BP/BPI plenum
Nominal Length
Duct Opening = Nominal Length + 41
Overall Length = Nominal Length + 2 41
1 81
1 81
Nominal Length
1 81
Overall Length = Nominal Length + 2 41
Nominal Length
1 81
Vertical Projection
Right Horizontal
Left Horizontal
S = 1"
Slot
8 3/4
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2 12 1/4
7 7/8
9 1/8
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
8 1/8
9 3/8
10 5/8
D2
2 3/8
4 1/8
5 7/8
7 5/8
9 3/8
8 1/4
9 1/2
10 3/4
2 1/2
4 1/4
7 3/4
9 1/2
11 1/4
7 3/4
10 1/4 11 1/2
3 1/4
6 3/4
8 1/2
10 1/4
12
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 1/4
7 1/2
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
D2
1 7/8
3 1/8
4 3/8
5 5/8
6 7/8
3 1/4
4 1/2
5 3/4
2 3/4
5 1/4
6 1/2
13
8
14
14 3/4
13 3/4 15 1/2
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8 12 3/8
D2
2 1/8
3 5/8
5 1/8
6 5/8
8 1/8
9 5/8
11 1/8 12 5/8
2 1/4
3 3/4
5 1/4
6 3/4
8 1/4
9 3/4
11 1/4 12 3/4
4 1/2
7 1/2
10 1/2
12
13 1/2
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
LSD-170
3/2006
Series 6600-40-7
Series 6600-42-7
1 41
D1 = Duct Opening
25
D2 = Duct Opening
A = Nominal Width
14
A = Nominal
1 1 Width
25
32
S*
W = Overall Width
25
32
25
32
Air Pattern
1
Controller
4
3
4
Air Pattern
Controller
25
32
S*
4 58
W = Overal Width
4 58
1 41
1
4
3
4
Hanger
Screw
13
1 41 4
1
4
3
4
Hanger
D2 = Duct Opening
Screw
3
Air Pattern
Controller
13
1 41 4
25
32
Air Pattern
Controller
A = Nominal Width
25
D1 = Duct Opening
32
W = Overall Width
Hanger
Screw
1 34
Air 1Pattern
4
Controller
4
A = 32
Nominal Width
S*
A = Nominal Width
1 34
25
32
S*
25
32
W = Overall Width
1 41
1
4
3
4
25
32
S*
25
32
W = Overal Width
D1 =- Duct
Opening Spline
Air Pattern
Supply
Concealed
= Nominal Width
ModelA6650-40-7
- 1/2" Slot Width Controller
Model 6675-40-7 - 3/4" Slot Width
Model 6610-40-7 - 1" Slot Width
1
4
3
4
25
32
S*
1 34
W = Overal Width
End Border
LSD
1
Ceiling Opening = Nominal Length + 2
7
1
Overall
Length
=
Nominal
Length
+ 16
Duct Opening = Nominal length + 4
1
Ceiling Opening = Nominal Length + 2
1
Duct Opening = Nominal length + 4
7
Overall Length = Nominal Length + 16
Vertical Projection
Right Horizontal
Left Horizontal
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 1/4
7 1/2
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
D2
1 7/8
3 1/8
4 3/8
5 5/8
6 7/8
2 1/16
3 5/16
S = 1"
Slot
8 3/4
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2
12 1/4
14
7 7/8
9 1/8
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
10 7/8
12 5/8
14 3/8
8 1/8
9 3/8
10 5/8
D2
2 3/8
4 1/8
5 7/8
7 5/8
9 3/8
11 1/8
12 7/8
14 5/8
8 5/16
9 9/16 10 13/16
2 9/16
4 5/16
6 1/6
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8
12 3/8
D2
2 1/8
3 5/8
5 1/8
6 5/8
8 1/8
9 5/8
11 1/8
12 5/8
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
LSD-171
Series 6600-40-8
Air Pattern
Controller
A = Nominal Width
Drop Face
Supply - Drop Face
Model 6650-40-8 - 1/2" Slot Width
Model 6675-40-8 - 3/4" Slot Width
Model 6610-40-8 - 1" Slot Width
1 41
25
32
1
4
3
4
25
32
S*
W = Overall Width
D1 = Duct Opening
A = Nominal Width
3/2006
Air Pattern
Controller
1 41
25
32
1
4
3
4
25
32
S*
W = Overall Width
End Border
Model 6600-40-8
1
2
LSD
1
2
Right Horizontal
Left Horizontal
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 1/4
7 1/2
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
D2
1 7/8
3 1/8
4 3/8
5 5/8
6 7/8
2 1/16
3 5/16
4 9/16
5 13/16
7 1/16
S = 1"
Slot
8 3/4
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2
12 1/4
14
7 7/8
9 1/8
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
10 7/8
12 5/8
14 3/8
8 1/8
9 3/8
10 5/8
D2
2 3/8
4 1/8
5 7/8
7 5/8
9 3/8
11 1/8
12 7/8
14 5/8
8 5/16
9 9/16
10 13/16
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8
12 3/8
D2
2 1/8
3 5/8
5 1/8
6 5/8
8 1/8
9 5/8
11 1/8
12 5/8
2 5/16
3 13/16
5 5/16
6 13/16
8 5/16
9 13/16
11 5/16 12 13/16
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
LSD-172
3/2006
Series 6600-40-9
Narrow Tee
End Border
LSD
Model 6600-40-9
Vertical Projection
Right Horizontal
Left Horizontal
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 1/4
7 1/2
8 3/4
S = 1"
Slot
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2
12 1/4
14
3 7/8
5 5/8
7 3/8
9 1/8
10 7/8
12 5/8
14 3/8
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
7 7/8
9 1/8
10 3/8
D1
2 1/8
2 1/16
3 5/16
4 9/16
5 13/16
7 1/16
8 5/16
9 9/16
10 13/16
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
10 7/8
12 3/8
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
2 5/16
3 13/16
5 5/16
6 13/16
8 5/16
9 13/16
11 5/16 12 13/16
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
LSD-173
Series 6600-22-74-1
D2 = Duct Opening
D2 = Duct Opening
8
1 81
4 58
4 58
3
4
Air Pattern
Controller
Air Pattern
3
Controller
S*
45
8
45
8
4
W= Overall Width
1 81
1 81
3
4
Air Pattern
A = Nominal Width
Controller
Hanger
Hanger
Screw
Screw
A = Nominal Width
45
1 81
Hanger
Screw
D2 = Duct Opening
D2 = Duct Opening
Air Pattern
A = Nominal Width
Controller
Hanger
Hanger
Screw
Screw
A = Nominal Width
45
3/2006
3
4
3
4
W= Overall Width
Air Pattern
Controller
Air Pattern
S* Controller
3
4
W= Overall Width
1 81
1 81
S*
3
4
S* 3
4
W= Overall Width
3
4
S*
3
4
3
4
W= Overall Width
S* 3
4
W= Overall Width
LSD
End Border
Models 6600-22-73 & 6600-22-74
1
2
3
4
3
4
1
2
3
4
4
Overall
Overall Length = T-Bar Module
- 41 Length = T-Bar Module -
Vertical Projection
Right Horizontal
3
1 4
4
Left Horizontal
Model 6650
Model 6610
S = 1/2"
Slot
1 1/4
2 1/2
3 3/4
6 1/4
7 1/2
D1
1 5/8
2 7/8
4 1/8
5 3/8
6 5/8
3 1/4
4 1/4
5 3/4
S = 1"
Slot
8 3/4
10
1 3/4
3 1/2
5 1/4
8 3/4
10 1/2
12 1/4
14
7 7/8
9 1/5
10 3/8
D1
2 1/8
3 7/8
5 5/8
7 3/8
9 1/8
10 7/8
12 5/8
14 3/8
8 1/4
9 1/2
10 3/4
2 1/2
4 1/4
7 3/4
9 1/2
11 1/4
13
14 3/4
Model 6675
Number of Air Slots
S = 3/4"
Slot
1 1/2
4 1/2
7 1/2
10 1/2
12
D1
1 7/8
3 3/8
4 7/8
6 3/8
7 7/8
9 3/8
10 7/8
12 3/8
2 1/4
3 3/4
5 1/4
6 3/4
8 1/4
9 3/4
11 1/4
12 3/4
6600R return has same dimensions as 6600 supply but provided without pattern controllers to reduce sound and pressure drop
Notes for Series 6600
1. Available Finishes
Standard Finish:
20 White frame with black pattern controller
Optional Finish
21 Clear anodized with black pattern controller
28 Custom color
2. Available Accessories
Mitered Corners (45, 90 and 135) . . . . . . . . . . . . . . . .335
Replacement End Caps
Insulated Boot Plenums
Non-Insulated Boot Plenums
3. Construction Details
Note:
BP Boot Plenums are shipped seperate for field installation
LSD-174
3/2006
Static
Pressure
Horizontal
Vertical
0.005
0.004
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
10
1-2-8
3
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
0.021
0.015
0.047
0.033
0.083
0.058
5
1-1-6
2
<15
<15
10
3-6-12
7
<15
<15
15
6-10-14
9
<15
<15
20
10-12-17
11
17
<15
15
2-4-13
5
<15
<15
30
6-13-20
11
<15
<15
45
13-18-25
16
15
<15
60
17-20-29
18
22
<15
20
4-8-17
9
<15
<15
30
8-14-20
13
<15
<15
0.130
0.091
0.188
0.132
0.255
0.179
0.334
0.234
0.422
0.295
0.521
0.365
25
11-13-19
12
22
<15
30
12-14-20
13
27
15
35
13-16-22
14
30
18
40
14-17-24
15
34
22
45
14-18-25
16
36
24
50
15-19-26
17
38
26
75
19-23-32
21
27
15
90
20-25-35
23
32
20
105
22-27-38
24
35
23
120
18-22-31
26
39
27
135
19-24-33
28
41
29
150
20-25-35
29
43
31
40
14-17-24
15
20
<15
50
15-19-26
17
25
<15
60
17-20-29
18
30
18
70
18-22-31
20
33
21
80
19-24-33
21
37
25
90
20-25-35
23
39
27
100
22-36-37
24
41
29
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
20
3-6-15
5
<15
<15
40
10-15-24
13
<15
<15
60
15-20-29
18
17
<15
80
19-24-33
21
24
<15
100
22-26-37
24
29
17
120
24-29-41
26
33
21
140
26-31-44
28
36
24
160
27-33-47
30
40
28
180
29-35-50
32
42
30
200
31-37-53
34
44
32
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
30
4-8-20
6
<15
<15
60
14-20-29
16
17
<15
90
20-25-35
23
20
<15
120
24-29-41
26
27
15
150
26-32-46
29
32
20
180
29-35-50
32
36
24
210
31-38-54
34
38
26
240
33-41-58
37
42
30
270
35-43-61
39
44
32
300
37-56-65
41
46
35
40
6-10-19
7
<15
<15
80
13-19-33
18
20
<15
120
19-29-41
26
22
<15
160
26-33-47
30
29
17
200
31-37-53
34
34
22
240
33-41-58
37
39
27
280
36-44-63
40
40
28
320
39-47-67
43
44
32
360
41-50-71
45
46
34
400
43-53-75
48
48
36
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
25
3-7-16
6
<15
<15
50
11-16-25
19
<15
<15
35
5-9-18
7
<15
<15
70
12-18-31
17
18
<15
75
16-23-32
23
19
<15
105
18-27-38
24
21
<15
100
22-26-3
26
26
<15
140
24-31-44
28
28
16
125
24-30-42
29
31
19
175
29-35-49
31
33
21
150
26-32-46
32
35
23
210
31-38-54
34
37
25
175
29-35-49
34
37
25
245
34-41-59
37
39
37
200
31-37-53
37
41
29
280
36-44-63
40
43
331
225
32-40-56
39
43
31
315
38-47-66
42
45
33
Slots
LSD
250
34-42-59
41
45
33
350
40-49-70
45
47
35
LSD-175
3/2006
LSD
Static
Pressure
Horizontal
Vertical
0.011
0.007
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
20
1-3-10
4
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
10
1-2-6
2
<15
<15
15
2-4-14
6
<15
<15
30
1-3-13
4
<15
<15
45
3-7-27
10
<15
<15
25
4-10-24
12
15
<15
60
6-13-36
17
<15
<15
75
9-20-41
21
20
<15
40
4-10-24
5
<15
<15
60
10-18-36
11
15
<15
60
10-15-29
6
<15
<15
90
15-22-44
14
17
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
70
11-16-32
7
16
<15
75
15-23-41
13
16
<15
105
16-24-48
15
18
<15
80
11-17-34
7
18
<15
120
17-25-51
16
19
<15
0.066
0.040
20
3-6-22
10
<15
<15
40
5-10-29
14
<15
<15
50
10-15-30
6
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
0.042
0.025
30
3-6-22
8
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
0.024
0.014
0.095
0.057
30
6-14-27
13
19
<15
0.129
0.077
35
9-19-29
14
23
<15
0.168
0.101
50
18-24-35
17
31
19
55
20-26-36
18
33
21
120
23-36-51
26
30
18
135
27-39-54
28
33
21
150
30-41-57
29
35
23
165
33-43-60
31
37
25
70
14-26-41
20
26
<15
80
19-29-44
21
28
16
80
16-24-42
20
16
<15
100
20-30-47
24
22
<15
120
24-36-51
26
25
<15
140
28-39-55
28
30
18
160
32-42-59
30
31
19
120
20-29-51
24
19
<15
150
24-37-57
29
24
<15
100
20-30-47
22
17
<15
140
21-32-55
26
20
<15
160
23-34-59
28
22
<15
125
25-37-52
27
23
<15
175
26-40-63
31
24
<15
200
28-42-66
34
25
<15
150
30-41-57
29
26
<15
180
29-44-63
32
28
16
210
32-48-68
34
29
17
240
34-51-73
37
30
18
175
35-44-62
31
32
20
210
34-48-68
34
33
21
245
37-52-73
37
34
22
280
40-55-78
40
35
23
200
38-47-66
34
33
21
240
39-51-73
37
34
22
280
42-55-78
40
35
23
320
45-59-84
43
37
25
LSD-176
0.318
0.191
45
14-26-33
16
28
16
60
10-22-38
18
22
<15
105
17-32-48
24
28
16
0.263
0.158
40
11-22-31
15
25
<15
50
7-16-35
17
18
<15
90
13-27-44
23
24
<15
0.213
0.128
90
22-33-46
23
31
19
180
36-44-63
32
35
23
225
41-50-70
36
36
24
270
44-54-77
39
37
25
315
48-59-83
42
38
26
360
51-63-89
45
39
27
100
25-35-49
24
34
22
200
38-47-66
34
37
25
250
43-52-74
38
38
20
300
47-57-81
41
39
27
350
51-62-88
45
40
28
400
54-66-94
48
41
29
110
27-36-51
25
36
24
220
40-49-70
35
39
27
275
45-55-78
39
40
28
330
49-60-85
43
41
29
385
53-65-92
47
42
30
440
57-70-9
50
43
31
3/2006
Static
Pressure
Horizontal
Vertical
0.008
0.003
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
20
1-3-10
4
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
40
4-10-24
5
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
0.047
0.020
0.068
0.028
20
3-6-22
10
<15
<15
25
4-10-24
12
<15
<15
30
3-7-18
4
<15
<15
60
12-18-36
17
<15
<15
75
15-23-41
21
<15
<15
90
18-27-44
23
17
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
50
10-15-30
6
<15
<15
100
20-30-47
24
<15
<15
125
25-37-52
29
16
<15
150
30-41-57
32
21
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
70
11-16-32
7
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
10
1-2-6
2
<15
<15
0.030
0.012
40
5-10-29
14
<15
<15
80
16-24-42
20
<15
<15
60
10-15-29
6
<15
<15
120
20-29-51
24
15
<15
140
21-32-55
26
16
<15
80
11-17-34
7
<15
<15
160
23-34-59
28
16
<15
50
7-16-35
17
<15
<15
100
20-30-47
24
15
<15
150
24-37-57
29
17
<15
175
26-40-62
31
18
<15
200
28-42-66
34
20
<15
30
6-14-27
13
<15
<15
60
10-22-38
18
<15
<15
120
24-36-51
26
19
<15
180
29-44-63
32
22
<15
210
32-48-68
34
24
<15
240
34-51-73
37
26
<15
0.092
0.037
35
9-19-29
14
19
<15
0.120
0.04
0.152
0.061
0.188
0.076
0.227
0.092
0.270
0.109
40
11-22-31
15
22
<15
45
14-23-33
16
24
<15
50
18-24-35
17
26
<15
55
20-26-36
18
28
16
60
22-27-38
18
30
18
105
21-32-48
24
22
<15
120
24-26-51
26
27
15
135
27-39-54
28
28
16
150
30-41-57
29
30
18
165
33-43-60
31
32
20
180
36-44-63
32
34
22
175
35-44-62
34
25
<15
200
38-47-66
37
31
19
225
41-50-70
39
32
20
250
43-52-74
41
34
22
275
45-55-78
43
35
23
300
47-57-81
45
37
25
70
14-26-41
20
21
<15
140
28-39-55
28
24
<15
210
34-48-68
34
27
<15
245
37-52-73
37
28
16
280
40-55-78
40
30
18
80
19-29-44
21
25
<15
160
32-42-59
30
29
17
240
39-51-73
37
33
21
280
42-55-78
40
34
22
320
45-59-84
43
35
23
90
22-33-46
23
27
15
180
36-44-63
32
30
18
270
44-54-77
39
34
22
315
48-59-83
42
36
24
360
51-63-89
45
37
25
100
25-35-49
24
29
17
200
38-47-66
34
32
20
300
47-57-81
41
35
23
350
51-62-88
45
37
25
400
54-66-94
48
38
26
110
27-36-51
25
31
19
220
40-49-70
35
34
22
330
49-60-85
43
36
24
385
53-65-92
47
37
25
440
57-70-98
50
39
27
120
29-38-54
26
33
21
240
42-51-73
37
36
24
Slots
LSD
360
51-63-89
45
38
26
420
55-68-96
49
39
27
480
59-73-103
52
41
29
LSD-177
3/2006
LSD
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
.02
15
35
55
70
90
110
130
140
.04
20
20
50
22
80
23
100
24
135
25
155
26
185
27
200
28
.06
25
27
60
27
95
28
120
30
155
30
195
33
225
33
245
34
.08
30
32
70
32
110
33
140
34
180
34
220
37
260
37
280
38
.10
35
37
80
37
125
37
155
37
200
37
245
40
290
41
310
42
.15
40
41
95
41
150
42
190
44
245
44
300
96
355
47
385
48
.02
25
55
90
-100
140
160
175
200
.04
35
21
80
25
115
26
140
27
185
28
225
29
250
30
285
31
.06
45
29
90
29
140
32
175
34
225
34
275
35
305
36
350
37
.08
50
32
100
32
160
36
200
38
260
38
320
40
350
40
400
41
.10
55
35
110
35
180
40
225
41
290
42
360
43
395
44
450
45
.15
70
42
135
42
220
46
275
47
360
48
440
49
480
50
545
51
.02
35
70
105
140
175
210
245
280
.04
50
25
100
27
150
29
200
31
250
32
300
33
350
34
400
35
.06
60
31
125
33
185
35
250
37
300
38
375
40
425
41
475
42
.08
70
36
140
37
210
39
280
41
350
42
420
43
490
44
560
45
.10
80
40
155
41
235
43
310
45
390
46
465
47
545
47
620
48
.15
95
45
190
47
285
49
380
51
475
52
570
53
665
54
760
55
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
LSD-178
3/2006
10
NC Correction
-2
+0
+2
+3
+5
10
12
Throw Correction
.7
1.0
1.5
1.7
1.8
4.
5.
6.
7.
8.
9.
LSD
Length (feet)
LSD-179
3/2006
LSD
Field Assembly
Units ordered longer than 8ft are shipped in multiple sections. Units
are provided with alignment pins to keep the 6600 diffusers straight
along continuous runs.
Concealed Mounting
3
1
LSD-180
3/2006
LSD
All drawings on this page are Plain View. A Plain View shows
the diffuser from behind - as if you were standing on the
floor above, looking down onto the back of the diffuser.
Note: For Duct Opening, Ceiling Opening, and Overall Width, see page LSD-83 - 90
LSD-181
45 Angle
LSD
Mitered Corners
3/2006
Number
of
Slots
Duct
Size
(All
Models)
1-2
24
6-8
48
3-5
Mitered Corners
O.L.
D = Duct Size
O.L. = Overall Length
MC6600-11-1
MC6600-12-1
MC6600-10-6
MC6600-12-6
O.L.
24-3/4
36
36-3/4
48-3/4
MC6600-20-6
MC6600-22-73
MC6600-22-74
MC6600-30-6
24-27/32
48-27-32
O.L.
36-27-32
MC6600-40-7
MC6600-42-7
MC6600-40-8
MC6600-40-9
24-5/16
24-29/32
24-29/32
48-5/16
48-29/32
48-29/32
O.L.
O.L.
36-5/16
36-29/32
O.L.
36-29/32
90 Angle
Number
of
Slots
Duct
Size
(All
Models)
1-3
12
4-8
LSD-182
24
MC6600-11-1
MC6600-12-1
MC6600-10-6
MC6600-12-6
O.L.
12 23/32
24 23 32
O.L.
D = Duct Size
MC6600-20-6
MC6600-22-73
MC6600-22-74
MC6600-30-6
12 11/32
12 1/8
O.L.
24 11/32
O.L.
24 1/8
MC6600-40-7
MC6600-42-7
MC6600-40-8
MC6600-40-9
12 3/8
12 3/8
O.L.
24 3/8
O.L.
24 3/8
3/2006
135 Angle
O.L.
D = Duct Size
Number
of
Slots
Duct
Size
(All
Models)
MC6600-11-1
MC6600-12-1
MC6600-10-6
MC6600-12-6
MC6600-20-6
MC6600-22-73
MC6600-22-74
MC6600-30-6
1-3
12
12-13/32
12-1/4
12-5/32
4-8
24
O.L.
24-13-32
O.L.
24-1/4
O.L.
24-5/32
MC6600-40-7
MC6600-42-7
MC6600-40-8
MC6600-40-9
12-9/32
12-9/32
O.L.
24-9/32
O.L.
LSD
Mitered Corners
24-9-32
LSD-183
3/2006
LSD
Linear Slot for Spiral Pipe - Aluminum - Surface Mount - 1 1/8" - Series 6600SP/6600SPR
Model 6610SP-11-1 - Supply - Screw Mounted
Model 6610SPR-11-1 - Return - Screw Mounted
Model 6610SP-12-1 - Supply - Concealed Mounting Hardware
Model 6610SPR-12-1 - Return - Concealed Mounting Hardware
1, 2, 3, 4
30" Round
Standard Finish:
20 White frame with black pattern controller
Optional Finish (additional charge):
21 Clear anodized with black pattern controller
28 Custom color
LSD-184
2. Construction Details
Sizes available in only 1-4 slots
Slot widths 1"
Longest single section is 6 feet
1, 2, 3
1, 2, 3, 4
24" Round
1. Available Finishes
1, 2, 3
16" Round
18" Round
Notes for Models 66(50,75,10)-( [10-6,12-6,20-6,30-6], [11-1,12-1], [40-7,42-7], [40-8], [40-9], [22-73,22-74] )
Available Slots
1, 2
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
3/2006
Static
Pressure
Horizontal
Vertical
0.008
0.003
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
20
1-3-10
4
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
40
4-10-24
5
<15
<15
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
CFM/LF
Horizontal Throw, ft
Vertical Throw, ft
Horizontal NC
Vertical NC
10
1-2-6
2
<15
<15
0.030
0.012
20
3-6-22
10
<15
<15
25
4-10-24
12
<15
<15
60
12-18-36
17
<15
<15
75
15-23-41
21
<15
<15
40
5-10-29
14
<15
<15
30
3-7-18
4
<15
<15
0.047
0.020
80
16-24-42
20
<15
<15
0.068
0.028
30
6-14-27
13
<15
<15
0.092
0.037
35
9-19-29
14
19
<15
0.120
0.04
40
11-22-31
15
22
<15
0.152
0.061
45
14-23-33
16
24
<15
0.188
0.076
50
18-24-35
17
26
<15
0.227
0.092
55
20-26-36
18
28
16
0.270
0.109
60
22-27-38
18
30
18
50
7-16-35
17
<15
<15
60
10-22-38
18
<15
<15
70
14-26-41
20
21
<15
80
19-29-44
21
25
<15
90
22-33-46
23
27
15
100
25-35-49
24
29
17
110
27-36-51
25
31
19
120
29-38-54
26
33
21
100
20-30-47
24
15
<15
120
24-36-51
26
19
<15
140
28-39-55
28
24
<15
160
32-42-59
30
29
17
180
36-44-63
32
30
18
200
38-47-66
34
32
20
220
40-49-70
35
34
22
240
42-51-73
37
36
24
90
18-27-44
23
17
<15
105
21-32-48
24
22
<15
120
24-26-51
26
27
15
135
27-39-54
28
28
16
150
30-41-57
29
30
18
165
33-43-60
31
32
20
180
36-44-63
32
34
22
Slots
LSD
LSD-185
3/2006
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
.02
35
70
105
140
.04
50
25
100
27
150
29
200
31
.06
60
31
125
33
185
35
250
37
.08
70
36
140
37
210
39
280
41
.10
80
40
155
41
235
43
310
45
LSD
Number of
Slots
1
Ak/Ft=.06
2
Ak/Ft=.11
3
Ak/Ft=.17
4
Ak/Ft=.23
LSD-186
.15
95
45
190
47
285
49
380
51
3/2006
NC Correction
-2
+0
+2
Throw Correction
.7
1.0
1..2
4.
5.
6.
7.
8.
9.
LSD
Length (feet)
LSD-187
3/2006
Supply units shall be furnished with the face white and the pattern controller black.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionize water rinse.
LSD
Property
LSD-188
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
Pencil Hardness
ASTM D3363-92A
70-80%
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
LSD
Model BP Shown w/
6600 Series Linear Slot Diffuser
(BP & BPI are shipped seperate for field installation)
Surface Mount
Screw Mounted
Drop Face
Narrow Tee
Concealed Spline
Surface Mount
Screw Mounted
LSD-190
Drop Face
Narrow Tee
Concealed Spline
BPI-42-7 25/32 Border
BPI-40-7 25/32 Border
3/2006
2-1/8
L/2
3-3/4
A
Available
Nominal Lengths
Model
1 Slot
2 5/8
Min = 3/4"
Max = 1-1/4"
Bottom of
Ceiling Plane
24
24
36
36
48
Ceiling opening =
Nominal Length + 1/2
48
60
60
Overall
Available Round
Oval
Models
6650 (1/2" Slot
Width) Model
6675
Slot Width)
Model
(1" Slot Width)
Length
( L(3/4"
)
Inlets
)
Dim.(A6610
Dim.(A x B)
N.L. - 1/16
BP (BPI)-12-1
6
5-7/8
Width (W)
Width (W)
Width (W)
8
N.L. - 2 7/16
BP (BPI)-12-6
5-7/8 x 8-15/16
N.L. -21Slot
1/4 3 Slot 10
BP (BPI)-22-73
- 2 Slot
5-7/8
x 12-1/16
2 Slot 3 Slot
4 Slot 1 Slot
4 Slot 1 Slot
3 Slot
4 Slot
12
BP (BPI)-22-74 N.L. - 1 1/4
5-7/8 x 15-1/4
3 7/8 5 BP
1/8 (BPI)-42-7
6 3/8 2 7/8
3/8 5 7/8 14
7 3/8 3 1/8
4 7/8
6
5/8
8 3/8
N.L. - 49/16
5-7/8 x 18-7/16
Models
BP (BPI)-12-1
8 7/8
Overall
Length (L)
N.L. - 1/16
5 Slot 6 Slot 7 Slot 8 Slot 5 Slot 6 Slot 7 Slot 8 Slot 5 Slot 6 Slot 7 Slot 8 Slot
7 5/8
Available Round
Oval Dim. (A x B)
Inlets Dim. (A)
6
5 7/8
8
10
BP (BPI)-22-74
N.L. - 1 1/4
Model 6610 (1" slot
width)
Model 6675 (3/4" slot width)
Model 6650 (1/2" slot width)
10 1/8 11 Width
3/8 8( W
7/8) 10 3/8 11 7/8 13Width
3/8 (10W1/8
3/8 ( W
BP) (BPI)-42-7 N.L. - 9/16
) 11 7/8 13 5/8 15Width
3-7/8
5-1/8
6-3/8
2-7/8
4-3/8
5-7/8
7-3/8
3-1/8
4-7/8
6-5/8
12
14
1 Slot 2 Slots 3 Slots 4 Slots 1 Slot 2 Slots 3 Slots 4 Slots 1 Slot 2 Slots 3 Slots 4 Slots
2-5/8
Bottom
of Hem
1-1/4
10
5 7/8 x 8 15/16
5 7/8 x 12 1/16
LSD
Insulation
(Option)
5 7/8 x 15 1/4
5 7/8 x 18 7/16
8-3/8
5 Slot 6 Slots 7 Slots 8 Slots 5 Slot 6 Slots 7 Slots 8 Slots 5 Slot 6 Slots 7 Slots 8 Slots
10-1/8 11-3/8
8-7/8 10-3/8 11-7/8 13-3/8 10-1/8 11-7/8 13-5/8 15-3/8
Non Insulated/Insulated7-5/8
Boot 8-7/8
Plenums
Steel - Straight Plenums
N.L.= Nominal Length
Model BP (BPI)-10-6 - T-bar Lay-in 1/8" Border
For the
Model BP (BPI)-20-6 -Note:
T-bar Lay-in
3/4"6600-12-1,
Border the BP/BPI plenum must be installed with 3/4" minimum/ 1-1/4" maximum
between the bottom of the ceiling plane and the bottom of the hem of the BP/BPI plenum
Model BP (BPI)-30-6 - opening
T-bar Lay-in
1/2" Border
Model BP (BPI)-11-1 - Surface Mount 1 1/8" Border
Model BP (BPI)-40-7 - Concealed Spline - 25/32" Border
Model BP (BPI)-40-8 - Drop Face - 25/32" Border
Model BP (BPI)-40-9 - Donn Fineline - 25/32" Border
W
L = Overall Length
2-1/8
L/2
3-3/4
A
Insulation
(Option)
15/16
Available Nominal
Lengths
Models
Width (W)
BP (BPI)-20-6
Available Round
Oval
48Inlets 60 Dim.(A )
Dim.(A x B)
6
5-7/8
8
- 6610 (1"
5-7/8
x 8-15/16
Model
Slot
Width)
N.L.6675
- 1/16(3/4" Slot Width) Model
10
5-7/8
x 12-1/16
N.L. - 2 7/16
12
5-7/8
x
15-1/4
Width
(W)
Width
(W)
N.L. - 1 7/16
14
5-7/8 x 18-7/16
N.L. - 15/16
Overall
24
36
Length ( L )
BP (BPI)-30-6
1 Slot 2 Slot 3 Slot
4 Slot 1 Slot 2 Slot 3 Slot 4 Slot 1 Slot 2 Slot 3 Slot 4 Slot
N.L. - 9/16
BP (BPI)-40-7
2 1/8 3 3/8 4 BP
5/8 (BPI)-40-8
5 7/8 2 3/8
7/8 5 3/8 6 7/8 2 5/8 4 3/8 6 1/8 7 7/8
N.L. -39/16
BP (BPI)-40-9
N.L. - 9/16
5 Slot 6 Slot 7 Slot 8 Slot 5 Slot 6 Slot 7 Slot 8 Slot 5 Slot 6 Slot 7 Slot 8 Slot
7 1/8
8 3/8
9 5/8
10 7/8
8 3/8
9 7/8
10
AvailableOverall
24 Available
36
48 Round
60
Models
Oval Dim. (A x B)
Nominal Lengths
Length (L)
Inlets Dim. (A)
BP (BPI)-11-1 N.L. - 1/16
6
5 7/8
BP (BPI)-10-6 N.L. - 2 7/16
8
5 7/8 x 8 15/16
BP (BPI)-20-6 N.L. - 1 7/16
10
5 7/8 x 12 1/16
14
5 7/8 x 18 7/16
12
5 7/8 x 15 1/4
3-3/8
4-5/8
5-7/8
2-3/8
3-7/8
5-3/8
6-7/8
2-5/8
4-3/8
6 1/8
7-7/8
8-3/8
9-5/8
10-7/8
8-3/8
9-7/8
11-3/8 12-7/8
9-5/8
LSD-191
3/2006
2' Length
4' Length
8" Inlet
1 Slot
2' Length
4' Length
10" Inlet
1 Slot
2' Length
LSD
4' Length
12" Inlet
1 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
2' Length
4' Length
8" Inlet
2 Slot
2' Length
4' Length
10" Inlet
2 Slot
2' Length
4' Length
12" Inlet
2 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
15
0.010
1-3-9
<15
30
0.016
2-4-7
<15
20
0.018
3-6-12
<15
40
0.018
3-5-10
<15
30
0.056
6-9-18
<15
60
0.036
5-7-15
19
45
0.047
9-13-23
24
90
0.098
7-11-21
23
30
0.038
6-9-18
20
60
0.063
5-7-15
24
35
0.054
7-10-20
18
70
0.056
6-9-17
24
45
0.126
9-13-23
22
90
0.082
7-11-21
27
60
0.083
12-18-27
28
120
0.175
10-15-24
30
45
0.086
9-13-23
28
90
0.142
7-11-21
34
50
0.110
10-15-24
27
100
0.115
8-12-22
33
60
0.225
12-18-27
29
120
0.146
10-15-22
34
75
0.129
15-21-30
32
150
0.273
12-18-27
36
60
0.153
12-18-27
35
120
0.252
10-15-24
41
65
0.185
13-19-28
33
130
0.194
11-16-25
39
75
0.351
15-21-30
34
150
0.227
12-18-27
40
90
0.186
18-23-33
35
180
0.393
15-21-30
41
75
0.240
15-21-30
41
150
0.394
12-18-27
45
80
0.281
16-22-31
38
160
0.294
13-20-28
43
90
0.505
18-23-33
39
180
0.328
15-21-30
45
105
0.254
20-25-35
39
210
0.535
17-23-32
45
90
0.345
18-23-33
45
180
0.567
15-21-30
46
95
0.396
19-24-34
42
190
0.415
16-22-31
45
105
0.688
20-25-35
42
210
0.446
17-23-32
48
120
0.331
22-27-38
42
240
0.699
20-24-35
48
105
0.470
20-25-35
47
210
0.772
17-23-32
49
110
0.531
21-26-36
44
220
0.556
18-23-33
45
120
0.899
22-27-38
43
240
0.582
20-24-35
51
135
0.419
23-28-40
45
270
0.884
21-26-37
51
20
0.007
1-2-8
<15
30
0.010
1-2-5
<15
25
0.007
1-3-10
<15
50
0.014
3-4-9
<15
35
0.013
3-6-15
<15
70
0.019
4-6-12
<15
50
0.024
6-10-21
<15
100
0.027
6-9-17
16
40
0.028
4-8-17
15
60
0.041
3-5-10
<15
45
0.023
5-9-19
<15
90
0.045
5-8-16
20
55
0.032
7-11-23
17
110
0.047
6-10-19
21
70
0.047
10-15-29
<15
140
0.053
8-12-24
23
60
0.064
8-12-25
25
90
0.093
5-8-16
24
65
0.049
9-14-27
23
130
0.094
8-11-23
29
75
0.059
10-16-30
23
150
0.088
9-13-26
29
90
0.078
12-19-33
17
180
0.087
10-16-30
29
80
0.114
11-17-31
32
120
0.166
7-10-21
32
85
0.084
12-18-32
29
170
0.161
10-15-29
36
95
0.095
13-20-34
29
190
0.142
11-16-31
35
110
0.117
15-23-36
21
220
0.130
13-19-33
34
100
0.178
14-21-35
38
150
0.259
9-13-26
37
105
0.128
15-22-35
35
210
0.245
12-18-32
41
115
0.139
16-24-37
34
230
0.207
13-20-34
40
130
0.163
18-27-39
24
260
0.181
15-23-36
38
120
0.256
17-25-38
43
180
0.373
10-16-30
41
125
0.181
17-26-39
39
250
0.348
14-22-35
45
135
0.191
19-28-40
38
270
0.286
16-23-37
43
150
0.217
21-30-42
28
300
0.241
17-26-39
41
140
0.349
19-29-41
46
210
0.507
12-18-32
43
145
0.244
20-29-42
43
290
0.468
17-25-38
46
155
0.252
21-30-43
41
310
0.377
18-27-39
45
170
0.279
24-32-45
31
340
0.310
20-29-41
43
LSD-192
3/2006
6" Inlet
3 Slot
2' Length
4' Length
8" Inlet
3 Slot
2' Length
4' Length
10" Inlet
3 Slot
2' Length
4' Length
12" Inlet
3 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
2' Length
4' Length
8" Inlet
4 Slot
2' Length
4' Length
10" Inlet
4 Slot
2' Length
4' Length
12" Inlet
4 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
25
0.008
1-2-7
<15
40
0.015
1-2-6
<15
35
0.009
2-3-12
<15
70
0.021
3-5-10
<15
45
0.011
3-6-15
<15
90
0.023
4-6-13
<15
65
0.022
5-11-22
<15
130
0.027
6-9-18
17
50
0.033
3-7-17
15
75
0.054
4-5-11
<15
55
0.022
4-9-19
<15
110
0.052
5-8-16
18
65
0.023
5-11-22
<15
130
0.048
6-9-18
20
85
0.038
9-14-29
16
170
0.046
8-12-24
22
75
0.073
7-13-25
24
115
0.127
5-8-16
23
80
0.046
8-14-27
21
160
0.109
8-11-23
27
90
0.044
10-15-31
21
180
0.091
8-13-25
27
110
0.063
12-19-36
20
220
0.077
10-16-31
27
100
0.130
11-17-34
31
150
0.216
7-11-21
29
105
0.079
12-18-35
28
210
0.188
10-15-30
34
115
0.072
13-20-37
27
230
0.149
11-16-33
33
135
0.095
15-23-40
23
270
0.117
13-19-37
33
125
0.203
14-21-39
36
190
0.347
9-13-27
36
130
0.122
15-22-39
33
260
0.289
12-18-36
39
140
0.106
16-24-41
32
280
0.221
13-20-36
38
160
0.133
18-27-44
26
320
0.164
15-23-40
37
150
0.293
17-25-42
40
225
0.486
11-16-32
40
155
0.173
18-26-43
37
310
0.410
15-22-39
44
165
0.147
19-28-44
36
330
0.307
16-23-39
42
185
0.178
21-31-47
29
370
0.219
17-26-43
41
175
0.398
20-30-46
43
265
0.674
12-19-36
44
180
0.233
20-31-46
41
360
0.553
17-25-42
47
190
0.195
21-32-48
39
380
0.407
18-27-42
45
210
0.229
24-35-50
32
420
0.282
20-30-46
44
40
0.018
1-3-12
<15
60
0.031
1-3-7
<15
50
0.014
2-5-15
<15
75
0.022
2-5-9
<15
60
0.014
3-7-18
<15
95
0.021
4-6-12
<15
80
0.018
5-12-24
<15
120
0.018
5-7-15
<15
65
0.047
3-8-19
16
100
0.087
4-6-12
16
80
0.036
5-12-24
17
120
0.056
5-7-15
16
90
0.032
7-13-26
17
135
0.043
6-8-17
16
120
0.041
12-18-35
<15
180
0.040
7-11-22
19
90
0.090
7-13-26
24
135
0.159
6-8-17
24
110
0.069
10-16-32
24
165
0.107
7-10-20
23
120
0.056
12-18-35
23
180
0.077
7-11-22
23
160
0.073
16-24-44
20
240
0.071
10-15-29
25
115
0.147
11-17-34
30
175
0.267
7-11-21
31
140
0.112
14-21-41
30
210
0.173
9-13-26
29
150
0.088
15-22-42
29
225
0.120
9-14-28
28
200
0.114
20-29-49
24
300
0.111
12-18-37
31
140
0.218
14-21-41
36
210
0.385
9-13-26
35
170
0.164
17-25-45
35
255
0.255
10-16-31
34
180
0.127
18-26-46
33
270
0.174
11-17-33
33
240
0.164
24-35-54
28
360
0.159
15-22-42
35
165
0.302
16-24-44
39
250
0.546
10-15-31
37
200
0.228
20-29-49
39
300
0.353
12-18-37
38
210
0.173
21-31-50
37
315
0.236
13-19-38
36
280
0.223
27-41-58
32
420
0.217
17-26-46
39
190
0.401
19-28-48
42
285
0.709
12-17-35
37
230
0.301
23-34-53
42
345
0.467
14-21-42
40
240
0.226
24-35-54
41
360
0.308
15-22-41
39
320
0.292
31-44-62
35
480
0.283
20-29-49
42
LSD
LSD-193
3/2006
2' Length
4' Length
8" Inlet
1 Slot
2' Length
4' Length
10" Inlet
1 Slot
2' Length
LSD
4' Length
12" Inlet
1 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
2' Length
4' Length
8" Inlet
2 Slot
2' Length
4' Length
10" Inlet
2 Slot
2' Length
4' Length
12" Inlet
2 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
20
0.014
1-3-10
<15
30
0.009
2-3-6
<15
25
0.036
2-5-12
<15
40
0.014
3-4-8
<15
35
0.085
4-8-17
<15
55
0.028
4-6-11
<15
65
0.022
5-11-22
<15
130
0.027
6-9-18
17
35
0.043
4-8-17
18
52.5
0.026
4-5-11
18
40
0.093
6-10-19
17
60
0.032
4-6-12
17
45
0.140
7-11-22
17
70
0.045
5-7-14
17
85
0.038
9-14-29
16
170
0.046
8-12-24
22
50
0.088
8-12-24
26
75
0.054
5-8-15
25
55
0.175
9-13-26
24
85
0.065
6-9-17
24
55
0.210
9-13-26
22
85
0.066
6-9-17
21
110
0.063
12-19-36
20
220
0.077
10-16-31
27
65
0.148
10-16-28
32
97.5
0.091
7-10-20
30
70
0.284
11-17-29
30
105
0.099
7-11-21
29
65
0.293
10-16-28
26
100
0.092
7-10-20
25
135
0.095
15-23-40
23
270
0.117
13-19-37
33
80
0.224
13-19-31
37
120
0.137
8-12-24
36
85
0.419
14-20-32
35
130
0.152
9-13-25
34
75
0.390
12-18-30
30
115
0.122
8-12-23
28
160
0.133
18-27-44
26
320
0.164
15-23-40
37
95
0.316
15-23-34
41
142.5
0.194
10-14-27
40
100
0.580
16-24-35
39
150
0.202
10-15-27
38
85
0.501
14-20-32
33
130
0.155
9-13-25
31
185
0.178
21-31-47
29
370
0.219
17-26-43
41
110
0.424
18-26-36
45
165
0.259
11-17-29
44
115
0.767
18-26-37
41
175
0.275
12-18-30
42
95
0.625
15-23-34
35
145
0.193
10-15-27
34
210
0.229
24-35-50
32
420
0.282
20-30-46
44
30
0.009
1-3-10
<15
45
0.009
1-3-6
<15
45
0.007
1-3-10
<15
70
0.014
3-5-10
<15
50
0.023
3-7-17
<15
75
0.025
4-5-11
<15
73
0.021
7-12-25
<15
110
0.025
5-8-16
<15
55
0.029
4-9-19
18
85
0.033
4-6-12
18
65
0.023
5-9-19
<15
100
0.028
5-7-14
17
70
0.045
6-12-24
17
105
0.050
5-7-15
16
95
0.036
11-16-32
18
145
0.044
7-10-21
20
80
0.061
8-14-27
27
120
0.065
6-8-17
25
85
0.049
9-14-27
23
130
0.047
6-9-18
23
90
0.074
10-15-31
22
135
0.082
6-10-19
21
120
0.058
14-20-38
21
180
0.068
8-13-25
24
105
0.105
12-18-35
33
160
0.116
8-11-23
33
105
0.084
12-18-32
29
160
0.071
8-11-23
28
110
0.111
12-19-36
27
165
0.123
8-12-23
26
145
0.084
16-25-42
25
220
0.102
10-16-31
29
130
0.161
15-22-39
39
195
0.172
9-14-28
37
125
0.128
15-22-35
35
190
0.100
9-13-27
33
130
0.155
15-22-39
32
195
0.171
9-14-28
30
170
0.116
19-29-45
28
255
0.137
12-18-36
33
155
0.228
18-26-43
42
235
0.250
11-17-33
41
145
0.181
17-26-39
39
220
0.135
10-16-31
37
150
0.207
17-25-42
35
225
0.228
11-16-32
34
195
0.152
22-33-48
31
295
0.183
14-21-38
36
180
0.308
20-31-46
44
270
0.330
13-19-37
43
165
0.244
20-29-42
43
250
0.174
12-18-35
39
170
0.265
19-29-45
38
255
0.293
12-18-36
37
220
0.194
25-36-51
34
330
0.229
16-23-41
39
LSD-194
3/2006
6" Inlet
3 Slot
2' Length
4' Length
8" Inlet
3 Slot
2' Length
4' Length
10" Inlet
3 Slot
2' Length
4' Length
12" Inlet
3 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
2' Length
4' Length
8" Inlet
4 Slot
2' Length
4' Length
10" Inlet
4 Slot
2' Length
4' Length
12" Inlet
4 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
45
0.012
1-3-12
<15
70
0.017
2-4-8
<15
55
0.012
2-5-15
<15
85
0.013
2-5-10
<15
65
0.015
3-7-18
<15
100
0.018
3-6-12
<15
85
0.022
5-11-24
<15
130
0.016
5-8-15
<15
70
0.029
3-8-19
17
105
0.037
4-6-12
17
85
0.029
5-11-24
18
130
0.031
5-8-15
18
100
0.037
7-14-28
19
150
0.041
6-9-17
18
120
0.043
10-17-33
<15
180
0.031
7-10-21
18
95
0.053
6-13-26
24
145
0.071
6-8-17
24
115
0.054
9-16-32
25
175
0.057
7-10-20
24
130
0.062
12-18-36
25
195
0.070
8-11-23
24
155
0.072
14-21-43
18
235
0.053
9-14-27
24
120
0.084
10-17-33
30
180
0.110
7-10-21
29
145
0.082
13-20-40
30
220
0.090
8-13-25
30
160
0.094
15-22-44
30
240
0.105
9-14-28
29
190
0.108
18-26-48
22
285
0.078
11-16-33
29
145
0.122
13-20-40
35
220
0.165
8-13-25
34
175
0.124
16-24-46
35
265
0.130
10-15-31
34
190
0.132
18-26-48
34
285
0.149
11-16-33
34
225
0.152
21-31-2
26
340
0.111
13-20-39
33
170
0.168
16-24-45
39
255
0.221
10-15-29
38
205
0.171
19-28-50
39
310
0.178
12-18-36
39
220
0.177
20-30-51
38
330
0.199
13-19-38
37
260
0.203
24-36-56
30
390
0.146
15-23-44
37
195
0.221
18-27-48
41
295
0.296
11-17-34
41
235
0.224
22-.33-53
42
355
0.233
14-20-41
42
250
0.229
23-35-55
41
375
0.257
14-22-42
40
295
0.261
27-41-59
33
445
0.190
17-26-47
39
50
0.011
1-3-10
<15
75
0.016
1-3-8
<15
70
0.016
1-3-8
<15
105
0.017
2-5-11
<15
80
0.014
3-6-19
<15
125
0.017
3-6-13
<15
100
0.007
4-10-24
<15
150
0.014
5-8-15
<15
80
0.029
3-6-19
16
120
0.042
3-6-12
16
100
0.042
3-6-12
18
150
0.034
5-8-15
17
110
0.027
5-12-26
17
165
0.030
6-8-17
16
140
0.014
9-17-34
16
210
0.028
7-11-21
19
110
0.055
5-12-26
23
165
0.079
6-8-17
23
130
0.079
6-8-17
24
195
0.057
7-10-20
23
140
0.044
8-1-34
23
210
0.049
7-11-21
22
180
0.023
14-22-43
20
270
0.046
9-14-27
24
140
0.089
9-17-34
30
210
0.129
7-11-21
29
160
0.129
7-11-21
29
240
0.086
8-12-24
28
170
0.065
13-20-41
27
255
0.072
9-13-26
26
220
0.034
18-26-51
23
330
0.069
11-17-33
28
170
0.131
13-20-41
35
255
0.190
9-13-26
34
190
0.190
9-13-26
33
285
0.122
10-14-29
32
200
0.090
16-24-48
32
300
0.099
10-15-20
30
260
0.047
21-31-56
26
390
0.096
13-20-39
32
200
0.181
16-24-48
39
300
0.263
10-15-30
37
220
0.263
10-15-30
37
330
0.163
11-17-33
36
230
0.119
18-28-53
35
345
0.131
12-17-35
34
300
0.063
24-36-60
29
450
0.128
15-23-45
36
230
0.239
18-28-53
43
345
0.348
12-17-35
39
250
0.348
12-17-35
39
375
0.211
13-19-38
39
260
0.152
21-31-56
38
390
0.167
13-20-39
37
340
0.081
27-41-64
32
510
0.164
17-26-50
39
LSD
LSD-195
3/2006
2' Length
4' Length
8" Inlet
1 Slot
2' Length
4' Length
10" Inlet
1 Slot
2' Length
LSD
4' Length
12" Inlet
1 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
2' Length
4' Length
8" Inlet
2 Slot
2' Length
4' Length
10" Inlet
2 Slot
2' Length
4' Length
12" Inlet
2 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
30
0.013
2-5-12
16
45
0.012
2-4-8
16
40
0.032
4-8-17
17
60
0.017
3-5-10
17
40
0.044
4-8-17
16
60
0.016
3-5-10
<15
48
0.018
5-10-20
<15
70
0.029
4-6-12
<15
45
0.029
5-9-19
23
70
0.029
4-6-12
23
50
0.051
6-10-21
22
75
0.026
4-6-13
21
55
0.083
7-11-23
24
85
0.033
5-7-15
21
65
0.033
9-14-27
<15
100
0.058
6-9-17
21
60
0.052
8-12-25
30
90
0.048
5-8-16
29
65
0.085
9-14-27
28
100
0.047
6-9-17
28
70
0.134
10-15-29
30
105
0.050
6-9-18
26
80
0.050
11-17-31
19
120
0.084
7-10-21
25
75
0.082
10-16-30
35
115
0.078
7-10-20
34
80
0.129
11-17-31
33
120
0.068
7-10-21
32
85
0.197
12-18-32
35
130
0.076
8-11-23
31
95
0.071
13-20-34
23
145
0.123
8-13-25
30
90
0.117
12-19-33
40
135
0.107
8-12-23
39
95
0.182
13-20-34
38
145
0.099
8-13-25
37
100
0.273
14-21-35
38
150
0.102
9-13-26
35
110
0.095
15-23-36
26
165
0.159
10-14-29
33
105
0.160
15-22-35
44
160
0.151
9-14-28
43
110
0.244
15-23-36
40
165
0.128
10-14-29
40
115
0.361
16-24-37
39
175
0.138
10-15-30
39
125
0.123
17-26-39
29
190
0.211
11-16-31
35
120
0.209
17-25-38
46
180
0.191
10-16-30
46
125
0.316
17-26-39
42
190
0.170
11-16-31
43
130
0.461
18-27-39
39
195
0.172
11-17-31
41
140
0.154
19-29-41
32
210
0.258
12-18-32
37
30
0.006
1-2-7
<15
45
0.009
1-2-6
<15
45
0.017
2-4-13
<15
70
0.014
2-4-9
<15
50
0.023
2-5-15
<15
75
0.012
2-5-9
<15
60
0.014
3-7-18
<15
90
0.017
3-6-11
<15
55
0.020
2-6-16
18
85
0.031
3-5-10
18
65
0.035
3-8-19
18
100
0.028
4-6-12
17
70
0.045
4-9-21
17
105
0.024
4-6-13
16
90
0.032
7-13-26
17
135
0.038
6-8-17
18
80
0.042
5-12-24
27
120
0.061
5-7-15
25
85
0.059
6-12-25
24
130
0.047
5-8-16
23
90
0.074
7-13-26
22
135
0.039
6-8-17
21
120
0.058
12-18-35
21
180
0.068
7-11-22
24
105
0.072
9-15-31
33
160
0.109
7-10-20
33
105
0.090
9-15-31
29
160
0.071
7-10-20
28
110
0.111
10-16-32
27
165
0.059
7-10-20
26
150
0.090
15-22-42
26
225
0.106
9-14-28
30
130
0.110
13-19-38
39
195
0.162
8-12-24
37
125
0.128
12-18-37
33
190
0.100
8-12-23
33
130
0.155
13-19-38
32
195
0.082
8-12-24
30
180
0.130
18-26-46
29
270
0.153
11-17-33
34
155
0.156
15-23-43
42
235
0.235
10-14-29
41
145
0.172
14-21-42
37
220
0.135
9-13-27
37
150
0.207
15-22-42
35
225
0.109
9-14-28
34
210
0.176
21-31-50
33
315
0.208
13-19-39
38
180
0.211
18-26-46
44
270
0.310
11-17-33
43
165
0.223
16-24-44
40
250
0.174
10-15-31
39
170
0.265
17-25-45
38
255
0.140
10-16-31
37
240
0.230
24-35-54
36
360
0.272
15-22-42
41
LSD-196
3/2006
6" Inlet
3 Slot
2' Length
4' Length
8" Inlet
3 Slot
2' Length
4' Length
10" Inlet
3 Slot
2' Length
4' Length
12" Inlet
3 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
2' Length
4' Length
8" Inlet
4 Slot
2' Length
4' Length
10" Inlet
4 Slot
2' Length
4' Length
12" Inlet
4 Slot
2' Length
4' Length
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
CFM
Static Pressure
Horizontal Throw, ft
NC
40
0.007
1-2-6
<15
60
0.011
1-2-6
<15
50
0.010
1-3-10
<15
75
0.008
1-3-8
<15
60
0.008
2-4-14
<15
90
0.008
2-4-9
<15
80
0.010
3-6-19
<15
120
0.009
3-6-12
<15
65
0.019
2-4-16
16
100
0.030
2-5-10
16
80
0.026
3-6-19
17
120
0.022
3-6-12
17
110
0.028
5-12-26
21
165
0.026
6-8-17
20
120
0.022
6-14-29
<15
180
0.021
6-9-18
18
90
0.036
4-8-22
23
135
0.055
4-7-14
22
110
0.049
5-12-26
24
165
0.041
6-8-17
23
140
0.045
9-17-34
27
210
0.042
7-11-21
26
160
0.038
11-19-38
19
240
0.038
8-12-24
25
115
0.058
6-13-28
29
175
0.093
6-9-18
28
140
0.080
9-17-34
29
210
0.066
7-11-21
28
170
0.066
13-20-41
32
255
0.062
9-13-26
31
200
0.060
16-24-48
23
300
0.059
10-15-30
30
140
0.087
9-17-34
34
210
0.134
7-11-21
33
170
0.117
13-20-41
34
255
0.098
9-13-26
33
200
0.092
16-24-48
36
300
0.086
10-15-30
35
240
0.086
19-29-54
28
360
0.084
12-18-36
35
165
0.120
12-20-40
38
250
0.190
8-13-25
37
200
0.162
16-24-48
38
300
0.135
10-15-30
38
230
0.122
18-28-53
39
345
0.113
12-17-35
38
280
0.118
22-34-58
31
420
0.115
14-21-42
38
190
0.160
15-23-46
41
285
0.247
10-14-29
40
230
0.215
18-28-53
42
345
0.179
12-17-35
41
260
0.155
21-31-56
42
390
0.145
13-20-39
40
320
0.154
26-38-62
35
480
0.150
16-24-48
41
50
0.009
1-2-6
<15
75
0.012
1-2-6
<15
70
0.017
1-3-13
<15
105
0.013
2-4-9<15
80
0.010
2-4-17
<15
125
0.012
2-5-11
<15
90
0.007
2-5-19
<15
135
0.008
3-6-12
<15
80
0.022
2-4-17
16
120
0.032
2-5-10
16
100
0.035
3-6-21
18
150
0.027
3-6-13
19
120
0.022
4-9-25
19
180
0.025
5-8-16
18
140
0.017
6-13-29
16
210
0.020
6-9-18
19
110
0.042
3-8-23
23
165
0.060
4-7-14
23
130
0.059
5-11-27
24
195
0.045
5-8-17
26
160
0.038
7-17-33
26
240
0.044
7-10-21
25
190
0.031
10-20-39
21
285
0.038
8-12-25
25
140
0.069
6-13-29
30
210
0.098
6-9-18
29
160
0.090
7-17-33
29
240
0.068
7-10-21
32
200
0.060
12-21-42
32
300
0.069
9-13-26
30
240
0.050
17-25-50
25
360
0.060
10-16-31
30
170
0.101
8-18-35
35
255
0.144
7-11-22
34
190
0.126
10-20-39
33
285
0.096
8-12-25
36
240
0.086
17-25-50
36
360
0.100
10-16-31
35
290
0.073
20-30-59
28
435
0.088
13-19-38
35
200
0.140
12-21-42
39
300
0.200
9-13-26
37
220
0.169
14-23-46
37
330
0.129
10-14-29
40
280
0.118
19-29-58
40
420
0.136
12-18-36
39
340
0.101
24-35-64
32
510
0.120
15-22-44
39
230
0.185
15-24-48
43
345
0.264
10-15-30
39
250
0.219
17-26-52
39
375
0.166
11-16-32
42
320
0.154
22-33-62
42
480
0.178
14-21-42
42
390
0.132
27-41-68
35
585
0.158
17-25-51
42
LSD
LSD-197
3/2006
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
.02
15
-35
-55
-70
-90
-110
-130
-140
--
.04
20
20
50
22
80
23
100
24
135
25
155
26
185
27
200
28
.06
25
27
60
27
95
28
120
30
155
30
195
33
225
33
245
34
.08
30
32
70
32
110
33
140
34
180
34
220
37
260
37
280
38
.10
35
37
80
37
125
37
155
37
200
37
245
40
290
41
310
42
.15
40
41
95
41
150
42
190
44
245
44
300
96
355
47
385
48
LSD
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
.02
25
-55
-90
-100
-140
-160
-175
-200
--
.04
35
21
80
25
115
26
140
27
185
28
225
29
250
30
285
31
.06
45
29
90
29
140
32
175
34
225
34
275
35
305
36
350
37
.08
50
32
100
32
160
36
200
38
260
38
320
40
350
40
400
41
.10
55
35
110
35
180
40
225
41
290
42
360
43
395
44
450
45
.15
70
42
135
42
220
46
275
47
360
48
440
49
480
50
545
51
.02
35
-70
-105
-140
-175
-210
-245
-280
--
.04
50
25
100
27
150
29
200
31
250
32
300
33
350
34
400
35
.06
60
31
125
33
185
35
250
37
300
38
375
40
425
41
475
42
.08
70
36
140
37
210
39
280
41
350
42
420
43
490
44
560
45
.10
80
40
155
41
235
43
310
45
390
46
465
47
545
47
620
48
.15
95
45
190
47
285
49
380
51
475
52
570
53
665
54
760
55
Negative Ps
Inches of Water
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
CFM/Ft.
NC
LSD-198
3/2006
Length (feet)
NC Correction
10
-2
+0
+2
+3
+5
10
12
.7
1.0
1.5
1.7
1.8
4.
5.
6.
7.
8.
9.
LSD
Performance Notes:
1. On units without BP/BPI plenums, pressure drop reported is across the diffuser element only. The field supply plenum pressure drop should be included when determining
system fan requirements. A good approximation of the static pressure requirements can be calculated by adding the velocity pressure through the plenum inlet to the diffuser
section pressure drop.
2. NC is based on a 4ft section of diffuser. The following table should be used to calculate sound levels for lengths other than 4 ft.
3. To correct throws for lengths other than the 4 ft lengths used in determining catalog performance, throws should be adjusted per the following table:
Series BP - Specification
Model BP Non Insulated
Model BPI - Insulated
Boot plenums for model 6600 (supply) or 6600R (return) linear slot diffusers shall be provided by the manufacturer (Optional: manufactured by METALAIRE).
The units shall be the size and quantity as outline in the plans and specifications. Units shall be constructed of coated steel.
Optional: Units shall include 12 internal fiberglass insulation. Insulation must be applied to the end caps.
LSD-199
3/2006
LSD
2 5/16
1 9/16
T-Bar Grid
Surface Mount
Series L-5000
Model L-5000-1 - Dimensions same as above (with screw holes)
Overall Diffuser =
Listed Size + 5 3/4
Overall
Diffuser =
Listed Size
+ 5 3/4
Neck Size =
Listed Size
- 1/8
1 1/2
2 5/16
1 9/16
T-Bar Grid
LSD-200
Overall Diffuser =
Listed Size + 5 3/4
3/2006
Neck Velocity
(VN) fpm
400
450
500
550
600
650
700
Total Pressure
.057
.072
0.94
.110
.130
.168
.180
42 x 3
An .875
350
394
480
481
535
568
610
Throw in ft.
11
12
14
15
15
17
18
42 x 4.5
An 1.312
525
591
656
722
788
853
919
Throw in ft.
13
14
16
17
19
20
22
Definition of Units:
CFM - Cubic feet per minute (air)
fpm - Velocity of air stream in feet per minute
Pt - Total pressure (inches of water column)
Throw - Cataloged throw is horizontal distances in feet to the terminal velocities
of 50 fpm with ambient supply air temperature.
An - Neck area
Core shall be removable without the use of tools. Outlets shall be engineered for high capacity applications and include straight deflector blades (without
a horizontal lip). Units with a horizontal lip at the ends of the deflector blades are not acceptable. The units shall be the size and quantity as outline in
the plans and specifications.
LSD
Linear ceiling diffusers shall be model L-5000 manufactured by METALAIRE. Units shall be aluminum construction and consist of a fixed pattern louvered
core fastened into a border with spring loaded latches. Optional: Units shall be designed to be configured as a combination supply/return unit.
Options:
IV Induction Vanes
Units shall include IV induction vanes factory mounted onto the back side of the deflector vanes.
IV vanes shall increase the induction rate of the diffuser.
Performance Specification
The manufacturer shall provide published performance data.
Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint.
Units shall undergo pre-treatment including a pressurized spray stage using an alkaine cleaner and a de-ionize water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
LSD-201
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
P
P
S
S
D
D
PLENUM
PLENUM
SLOT DIFFUSERS
SLOT DIFFUSERS
3/2006
Series PHP
Pg. 206
Heavy duty extruded aluminum pattern controller and gasket for tight horizontal discharge pattern
Field adjustable pattern controllers allow adjustable horizontal and vertical throw
Units available in 1 to 4 slots to meet a wide range of applications and capabilities
Double hem face construction for rigidity and straightness
PHPR return model offers low pressure drop return; Integral light shield hides interior of unit
One-piece plenum construction ensures tight fit in ceiling grid
Optional 1/4 insulation on PHPI-6 units
Lay-in (type 6) integrates into 1 T-bar ceiling
T-bar Lay-in
Supply
Fineline Ceilings
Return
Supply
Return
Insulated
PHPSI-6
PHPRI-6
Non-Insulated
PHPS-6
PHPR-6
PHPS-9 Supply
w/ Center Tee
PHNS-9 Supply
w/ hat section
PHPR-9 Return
w/ Center Tee
PHNR-9 Return
w/ hat section
High Capacity Plenum Slot Diffusers - Fixed Pattern Controller - Series PHC
Series PHC
PSD
Pg. 224
Aerodynamically shaped, heavy duty extruded aluminum curved blade pattern controller generates a tight
horizontal discharge pattern
Excellent selection for perimeter applications, especially in cold climates because of its high induction ratio
Available with integral return, a low cost and efficient solution to return air into the ceiling plenum
Optional 1/4 insulation on PHCSI-6, PHCRI-6, PHCSI-DB-6, and PHCRI-DB-6
T-bar Lay-in
Insulated
PHCSI-6
Supply
PHCRI-6
Supply - with Return
Non-Insulated
PHCS-6
Supply
PHCR-6
Supply - with Return
Series
Pg. 230
Architecturally pleasing; Reduces ceiling clutter by integrating the ceiling diffuser into the light fixture
Each unit is customized to fit the specified light fixture ensuring a tight seal for optimum performance
Optional 1/2 internal insulation available
Available with single or double-sided supply configurations
Model DS-LT-6 double-sided diffusers are available with side or top inlet for installation flexibility
Matching single-sided plenum return unit model SSR-LT-6 is available
T-bar Lay-in
PSD-204
Insulated
SSI-LT-6
DSI-LT-6 Double Side - DSTI-LT-6 Double
Single Side Side Inlet
Side - Top Inlet
SSRI-LT-6
Single Side Return
Non-Insulated
SS-LT-6
DS-LT-6
DST-LT-6 Double
Single Side Double Side - Side Inlet Side - Top Inlet
SSR-LT-6
Single Side Return
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suites your air distribution design needs.
Our Pre-Flite catalog is a condensed reference guide containing the listing of our
complete product offers for grilles, registers, diffusers, and air terminal units. This
catalog can be used to help select the type of device, along with available border
styles. The catalog includes photos of each model along with the features and
model guide, a great tool when you are trying to select a device for your project.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalog and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog is the leading product catalog in the industry. Included
in this catalog are the complete product listings, drawings, product features and benefits,
product performance data, specifications, and model specifications. This catalog is
organized to make it quick and easy to find the information you are looking for.
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
PSD
Product Details
Heavy duty extruded aluminum pattern controller
and gasket for tight horizontal discharge pattern
Non Insulated
Model PHPS-50-6 - 1/2" Slot Width
Model PHPS-75-6 - 3/4" Slot Width
Model PHPS-10-6 - 1" Slot Width
Model PHPS-15-6 - 1 1/2" Slot Width
2 18
2 18
2 18
Insulation
(Optional)
elt Wiper
ir Seal
ir Pattern
eflection
Felt Wiper
Air Seal
Air Pattern
Deflection
1
2
Air Pattern
Deflection
Felt Wiper
Air Seal
1
2
Air Pattern
Deflection
1
2W
W2
A
2 18
Insulation
(Optional)
1 Slot
1 Insulation
21
2 (Optional)8
Felt Wiper
Air1Seal
1
2
Insulated
Model PHPSI-50-6 - 1/2" Slot Width
Model PHPSI-75-6 - 3/4" Slot Width
Model PHPSI-10-6 - 1" Slot Width
Model PHPSI-15-6 - 1 1/2" Slot Width
2 18
Insulation
(Optional)
Insulation
(Optional)
2 18
Insulation
2 18
(Optional)
1
2
1
2
Felt Wiper
Air Seal
Air1Pattern
Deflection
A
B
1
2
1
2W
Insulation
(Optional)
2 Slot
1
2
W
A
Felt Wiper
Air Seal
Air Pattern
Deflection
Air Pattern
Deflection
A
B
Insulation
2 18
(Optional)
1
2
1
A
B
W
W1
1
2
2 18
Insulation
(Optional)
1
2
1
2
Air Pattern
Deflection
Felt Wiper
Felt Wiper
Air Seal
Air Seal
1
Air Pattern
2 Air Pattern
1
Deflection
Deflection
1 2
Felt Wiper
Air Seal
1
2
Felt Wiper
Air Seal
1
2
Insulation
1 21
(Optional)
8
2
3 Slot
1
A
B
1
2
1
2
1
1
A 2
B
1
W
1
2
Felt Wiper
1Air Seal
2
Felt Wiper
Air Seal
Air Pattern
Deflection
Air Pattern
Deflection
1
2
1
2
1 2
W
W
W
W
A
B
Air Pattern
Deflection
Felt Wiper
Air Seal
1
Air Pattern
2
Deflection
Insulation
(Optional)
Insulation
2 18
(Optional)
Felt Wiper
Air Seal
A
B
Insulation
1
2 18
(Optional)
2 18
W
1W
4 Slot
Insulation
2 18
(Optional)
Insulation
(Optional)
1
2
Felt Wiper
Air Seal
Air Pattern
1
Deflection 1
1
2 1
1 2A
2 1
2
1
WW
AW
B
W
AW
1
B
A
B
D
10
T-Bar By Others
D
C
D
10
10
1
Overall = T-Bar Module - 4
T-Bar Module
PSD-206
1
1
T-Bar
By
Others
Overall = T-Bar
Module
-4
Overall
= T-Bar
Module
1
T-Bar
By
Others - 4
Overall
= T-Bar Module - 4
1
T-Bar Module
Overall = T-Bar Module - 4
T-Bar Module
T-Bar Module
T-Bar Module
10
10
(Optional)
1
2
Felt Wiper
Air Seal
Felt Wiper
Air Seal
Air Pattern
1
2
Deflection
Air Pattern
Deflection
1
2Insulation
8
1
2
1
2
1
8
1
2
1
2
W
W
W
Insulation
2 18
(Optional)
1
2
1 2
W
W
Felt Wiper
Air Seal
Air Pattern
Deflection
A
B
11
Insulation
(Optional)
1
2
Felt Wiper
Air Seal
Insulation
2 18
(Optional)
1
2
Air Pattern
Deflection
1
2
W
W
W W
A
B
1
2
1
2
1W
W
WW
A
B
1 1
1
A
B
1
2
W
W
3/2006
No Pattern Controller
1
2
Insulated
Model PHPRI-50-6Insulation
- 1/2" Slot Width
(Optional)
Model PHPRI-75-6 - 3/4" Slot Width
Model PHPRI-10-6 - 1" Slot Width
1
Model PHPRI-15-6
- 1 1/2" Slot Width
2
1 Slot
11
22
1
21
2
A
B
W
W
A
W
B A
B
1
2
1
2
2 Slot
Insulation
Insulation
(Optional)
(Optional)
1
2
1
2
W
W W
A
A
B
1 21
W
A
B
A
B
1
2
1
2
3 Slot
Insulation
W
(Optional)
1
2
1
2
1 11
2 22
1
2
Insulation
1
2
(Optional)
Insulation
1
Insulation
2
(Optional) (Optional)
1
2
1
2
1
121
4 Slot
11
22
1
2
W W
A W
A
B
W
A
B
A
1
B
1
2
1
2
Insulation
1 Insulation
Insulation
2
(Optional)
(Optional)
1
2
Insulation
(Optional)
(Optional)
1
2
1
2
1
2
1W
W1
A
B
1
W
1 12
2
W
W W
1
2
A
B
1
2
W
W
A
B
221
221
T-Bar by Others
Inlet Size
6 Round
D
5 7/8
12 1/16
8 Oval
8 15/16
12 Oval
15 1/4
10 Oval
T-Bar by Others
6
6
Supply
Models
Return
1/2
1
2
PHPS(I)-75-6 PHPR(I)-75-6 24, 36, 48, 60 23/4
PHPS(I)-10-6 PHPR(I)-10-6 24, 36, 48, 60
1
21
PHPS(I)-15-6 PHPR(I)-15-6 24, 36, 48, 60 121/2
1 Slot
1 1/2
5
1 3/4
2
2 1/2
2 Slots
3 1/2
2 3/4
1 3/4
2 1/4
T-Bar by Others
Overall = T-Bar Module - 41
3 1/4
3 3/4
1
4 22 4 1/4
221
5
5 1/4
3 Slots
4 1/2
5 1/4
6
7 1/2
5 1/2
4 3/4
6 1/4
7 3/4
4 Slots
6 1/4
28211/4
10
7 1/4
10 1/45
221
221
221
1
2
1 W
W
W A
PSD
1
2
Insulation
Insulation
1
(Optional)
(Optional)
Insulation
(Optional)
Non Insulated
Insulation
Model
PHPR-50-6 - 1/2" Slot Width
(Optional)
Model PHPR-75-6 - 3/4" Slot Width
Model PHPR-10-6 - 1" Slot Width
Model PHPR-15-6 - 1 1/2" Slot Width
PSD-207
tion
nal)
1 SlotAir Pattern
2
1
2
Insulation
(Optional) Insulation
2 18
21
1
8
Felt Wiper
Air Seal
Air Pattern
Deflection
1
2
Insulation
(Optional)
1
2
1
2
1
2
Felt Wiper
Air Seal
Air Pattern
Deflection
W
A
B
1
2
1
A
B
Insulation
(Optional)
Insulation
1
8
1
8
(Optional)
1
2 21
Insulation
(Optional)
2 18
Air Pattern
W
A
B
1
2
13
8
WB
A
B
1
2
1
2
A
Felt Wiper
B Air Seal
1
A
B
1
2
1
2
Inlet Size
6 Round
PSD
End Clip
(4 Places)
Supply
10
24, 48
PHPS(I)-10-9 24, 48
( 4 Places )
W
1
End Clip
(4 Places)
10
PHPS(I)-10-9 24, 48
Mounting Angle
( 4 Places )
PHPS(I)-15-9 24, 48
Mounting Angle
Split Deflector
Shown
Overall = T-Bar
Module - 41
End
Clip
Split Deflector Shown ( 4 Places )
(on 36, 48 and
60"
Units)
= T-Bar Module(on 36, 48 and 60" Units)
(4L Places)
L = T-Bar Module
PSD-208
5
8
L = T-Bar Module
1
2
1
13
8
2
AW
B
D
5 7/8
12 1/16
5
8
3 1/2
4 1/8
2 1/2
3 1/8
4 5/8
2 5/8
10
A
B
2 3/8
13
8
WW
A
B
1 3/4
2
5
8
1
21
2
13
8
2 Slots
w/ Center Tee
Mounting Angle
( 4 Places )
Air Pattern
Deflection
1 Slot
w/ Center Tee
10
Felt Wiper
Air Seal
Air Pattern
Deflection
15 1/4
Felt Wiper
Air Seal
12 Oval
3/4
Insulation
(Optional)
2 18
1
2
8 15/16
D
C
1
2
8 Oval
10 Oval
Insulation
(Optional)
Air Pattern
Deflection
1
2
Insulation
(Optional)
28
1
2
1
2
Air Pattern
Deflection
1
2
1
2
2 18
5
8
Felt Wiper
Air Seal
AirDeflection
Pattern
Deflection
Insulated
Model PHNSI-75-9 - 3/4" Slot Width
Model PHNSI-10-9 - 1" Slot Width
Model PHNSI-15-9 - 1 1/2" Slot Width
1
2
FeltWiper
Wiper
Felt
Seal
AirAirSeal
Air Pattern
Deflection
1
2
1
2
Felt Wiper
Air Seal
W
A
B
Air Pattern
Deflection
Deflection
(Optional)
2
Non Insulated
Model PHNS-75-9 - 3/4" Slot Width
Felt Wiper
Model PHNS-10-9
- 1" Slot Width
Air Seal
Model PHNS-15-9 - 1 1/2" Slot Width
Insulated
Model PHPSI-75-9 - 3/4" Slot Width
Model PHPSI-10-9 - 1" Slot Width
Model PHPSI-15-9 - 1 1/2" Slot Width
Air Seal
Insulation
(Optional)
2 18
Insulation
(Optional)
2 18
3/2006
A
4
4 5/8
2 Slots
w/ Hat Section
A
3 7/8
4 1/4
5 3/8
4 3/8
1
2
3/2006
1 Slot
1/4 Insulation
(Optional)
1/4 Insulation
1
1
1/4 Insulation
2
2
1
(Optional)
(Optional)
W
on
al)
1
2
1
2
1
2
W
A
Non Insulated
Model PHNR-75-9 - 3/4" Slot Width
1/4 Insulation
Model PHNR-10-9 - 1"(Optional)
Slot Width
Model PHNR-15-9 - 1 1/2" Slot Width
1
A
B
1
2
A
B
1
2
1
2
1
A
B
5
8
1/4 Insulation
1/4 Insulation
(Optional) (Optional)
A
B
1
2
1
2
5
8
Inlet Size
Mounting Angle
( 4 Places)
Return
L
PHPR(I)-75-9 24, 48
PHPR(I)-10-9 24, 48
L = T-Bar Module
1. Available Finishes
End Clip (4
PHPR(I)-15-9 24, 48
PHPR(I)-10-9 24, 48
2. Available Accessories
Standard Finish:
25-WT White Tees with Black Borders
Optional Finish
26 White Tees and Borders
Places)
27 Black Tees and Borders
22
1. Available Finishes
L = T-Bar Module
- 58
L = T-Bar Module
2 3/8
3 1/2
4 1/8
2 1/2
3 1/8
4 5/8
2 5/8
1
2
A
4
4 5/8
2 Slots
w/ Hat Section
A
3 7/8
4 1/4
5 3/8
4 3/8
2 21
Mounting Angle
CN - HS center hat section for 2 slot units (see PHNS models)
( 4 Places)
2. Available Accessories
Standard Finish:
25-WT White Tees with Black Borders
Plenum = Ceiling Module
Optional Finish
26 White Tees and Borders
Overall
= T-Bar Module - 41
27 Black
Tees and Borders
1 3/4
2
A
B
6
2 Slots
w/ Center Tee
1 38
1 Slot
w/ Center Tee
A
5
8
3. Construction Details
15 1/4
12 1/16
12 Oval
W
3/4
PHPR(I)-75-9 24, 48
D
5 7/8
8 15/16
8 Oval
10 Oval
1
2
A
B
6 Round
2 21
1
2
1 38
1
2
A
B
2 21
1/4 Insulation
(Optional)
1
2
1
2
2
1 38
Insulated
Model PHNRI-75-9 - 3/4" Slot Width
Model PHNRI-10-9 - 1" Slot Width
Model PHNRI-15-9 - 1 1/2" Slot Width
Insulated
Model PHPRI-75-9 - 3/4" Slot Width
1/4 Insulation
Model PHPRI-10-9 - 1" Slot Width
(Optional)
Model PHPRI-15-9 - 1 1/2" Slot Width
PSD
sulation
ptional)
Non Insulated
Model PHPR-75-9 - 3/4" Slot Width
Model PHPR-10-9 - 1" Slot Width
Model PHPR-15-9 - 1 1/2" Slot Width
1
3.2
Construction
Details
2
2 21
2 21
L = T-Bar Module
PSD-209
3/2006
Horizontal
2' Length
6" Inlet
Vertical
1/2"
Slot
Width
Horizontal
4' Length
6" Inlet
Vertical
Horizontal
PSD
5' Length
8" Inlet
Vertical
Horizontal
2' Length
8" Inlet
Vertical
3/4"
Slot
Width
Horizontal
4' Length
8" Inlet
Vertical
Horizontal
5' Length
8" Inlet
Vertical
CFM
Ps
Pt
Throw
NC
10
20
0.01
0.011
3
6
15
CFM/LF
30
0.023
0.024
3
5
8
<10
25
40
60
90
Ps
Pt
Throw
NC
0.013
0.014
1
1
3
0.029
0.031
1
2
4
<10
0.082
0.086
2
3
7
15
Ps
Pt
Throw
NC
0.013
0.015
2
3
5
0.029
0.035
3
4
8
<10
0.08
0.205
0.462
0.722
1.039
0.096
0.247
0.555
0.867
1.249
4
6
13 7 10 20 10 15 30 13 19 38 15 23 46
18
32
41
45
48
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
40
0.01
0.013
2
3
7
50
0.01
0.011
4
8
<10
0.209
0.471
0.736
0.22
0.495
0.773
4
5
11 5
8
16 7 10 20 8
29
38
42
1.06
1.885
1.113
1.978
12 24 11 16 32
45
52
75
125
200
300
375
450
0.022
0.061
0.157
0.353
0.551
0.794
0.025
0.07
0.18
0.405
0.633
0.912
4
6
12 7 11 16 11 14 20 14 17 24 16 19 27 17 21 29
11
22
34
44
48
52
Ps
Pt
Throw
NC
0.013
0.014
2
3
7
<10
0.028
0.079
0.201
0.453
0.707
1.018
0.032
0.088
0.224
0.505
0.789
1.136
3
5
10 5
8
16 9 13 26 13 20 40 16 25 49 20 30 59
12
26
39
46
50
55
Ps
Pt
Throw
NC
0.008
0.008
1
1
2
0.017
0.018
1
2
3
0.048
0.05
2
3
5
<10
Ps
Pt
Throw
NC
0.008
0.008
1
2
4
<10
0.017
0.019
2
3
12
0.047
0.121
0.272
0.424
0.611
0.053
0.136
0.305
0.477
0.686
3
5
10 6
8
17 8 12 25 10 15 31 12 19 37
27
39
44
48
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
20
0.007
0.007
2
3
5
40
0.006
0.007
2
3
6
50
0.006
0.008
2
4
0.007
0.009
2
3
120
60
100
160
240
300
360
0.023
0.063
0.16
0.36
0.563
0.81
0.028
0.079
0.201
0.453
0.708
1.02
3
5
10 6
8
14 9 12 18 12 15 22 14 17 24 15 19 26
<10
20
32
42
46
50
30
0.015
0.015
3
4
7
60
0.014
0.016
3
4
8
<10
50
0.041
0.042
4
6
9
<10
80
120
150
180
240
0.104
0.235
0.367
0.528
0.939
0.108
0.243
0.38
0.973
7
8
12 8 10 14 9 11 16 10 12 17 12 14 20
23
32
37
40
47
0.123
0.127
3
4
9
24
0.277
0.433
0.623
1.108
0.285
0.446
0.642
1.141
4
7
13 5
8
16 7 10 20 9 13 26
36
41
45
54
100
160
240
300
360
0.04
0.102
0.23
0.36
0.518
0.046
0.117
0.264
0.412
0.593
5
7
13 7 11 16 11 14 20 13 16 22 14 17 25
15
26
35
40
43
75
125
200
300
375
450
0.014
0.039
0.1
0.226
0.353
0.508
0.017
0.048
0.124
0.278
0.434
0.626
4
6
11 6
9
14 10 13 18 13 16 22 14 18 25 16 19 27
<10
17
28
37
42
45
0.017
0.02
3
4
<10
0.046
0.118
0.266
0.416
0.599
0.055
0.142
0.319
0.498
0.717
4
7
13 7 11 22 11 16 32 13 20 40 16 24 48
14
29
41
46
50
PSD-210
75
50
80
120
150
180
240
0.064
0.163
0.367
0.574
0.826
1.469
0.068
0.174
0.39
0.61
0.879
1.562
5
7
10 7
9
12 9 11 15 10 12 17 11 13 19 12 15 22
17
29
39
43
47
56
3/2006
Vertical
Horizontal
1"
Slot
Width
4' Length
8" Inlet
Vertical
Horizontal
5' Length
10" Inlet
Vertical
Horizontal
2' Length
8" Inlet
Vertical
Horizontal
1-1/2"
Slot
Width
4' Length
8" Inlet
Vertical
Horizontal
5' Length
10" Inlet
Vertical
11
10
25
50
0.028
0.030
6
10
0.044
0.046
2
<10
100
0.028
0.034
5
13
0.043
0.049
4
<10
125
0.027
0.032
10
15
0.042
0.047
5
11
50
0.027
0.028
4
<10
0.020
0.022
1
100
0.026
0.032
6
<10
0.020
0.026
3
<10
125
0.026
0.031
9
<10
0.020
0.024
4
<10
11
14
10
11
12
13
10
40
80
0.073
0.076
8
23
0.113
0.116
3
22
160
0.071
0.086
9
26
0.111
0.125
6
25
200
0.070
0.082
13
28
0.108
0.120
9
27
80
0.069
0.073
6
13
0.052
0.056
2
<10
160
0.068
0.082
9
16
0.051
0.066
5
12
200
0.066
0.078
12
18
0.050
0.062
7
14
11
16
13
18
18
11
15
10
17
13
CFM/LF
60
120
0.163
0.172
8 10 14
32
0.254
0.262
3 4
9
35
240
0.160
0.194
9 13 19
35
0.249
0.282
6 10 19
38
300
0.157
0.184
13 15 22
37
0.244
0.271
9 13 26
40
120
0.155
0.163
6 9 13
22
0.117
0.125
2 3
7
19
240
0.152
0.186
9 13 18
25
0.115
0.148
5 7 14
22
300
0.149
0.176
12 15 21
27
0.112
0.139
7 10 20
24
11
14
11
12
13
75
150
0.255
0.268
11
36
0.396
0.410
5
40
300
0.250
0.303
15
39
0.389
0.441
12
43
375
0.245
0.287
17
41
0.381
0.423
16
45
150
0.242
0.255
10
29
0.183
0.196
4
25
300
0.237
0.290
15
32
0.179
0.231
9
28
375
0.233
0.275
16
34
0.176
0.217
12
30
15
10
11
22
13
24
10
24
15
33
13
15
21
13
18
23
15
25
10
90
180
0.368
0.387
12
39
0.571
0.590
7
43
360
0.361
0.436
17
42
0.560
0.635
14
46
450
0.353
0.413
19
44
0.549
0.609
20
48
180
0.349
0.368
11
34
0.263
0.282
5
30
360
0.342
0.417
16
37
0.258
0.333
11
33
450
0.335
0.395
18
39
0.253
0.313
15
35
17
11
13
24
16
29
13
27
18
39
18
16
11
10
23
15
21
10
25
17
30
13
120
240
0.654
0.687
14
44
1.015
1.048
9
47
480
0.641
0.775
19
47
0.995
1.129
19
50
600
0.628
0.735
22
49
0.975
1.082
26
52
240
0.620
0.654
13
42
0.468
0.501
7
37
480
0.608
0.742
18
45
0.458
0.593
14
40
600
0.596
0.703
21
47
0.449
0.556
20
42
19
13
18
28
38
31
53
18
12
13
26
17
29
13
29
19
40
18
160
320
1.162
1.222
16
53
1.804
1.864
12
55
320
1.102
1.162
15
50
0.831
0.891
9
45
640
1.081
1.319
21
53
0.815
1.054
19
48
800
1.059
1.249
24
55
0.799
0.989
27
50
23
23
2' Length
8" Inlet
15
30
0.010
0.011
5
<10
0.016
0.016
1
60
0.010
0.012
3
<10
0.016
0.018
2
75
0.010
0.011
8
<10
0.015
0.017
3
<10
30
0.010
0.010
2
0.007
0.008
1
60
0.009
0.012
3
0.007
0.009
2
75
0.009
0.011
6
0.007
0.009
2
PSD
Horizontal
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
10
20
0.005
0.005
4
0.007
0.007
1
40
0.004
0.005
2
0.007
0.008
2
50
0.004
0.005
6
0.007
0.008
2
20
0.004
0.005
2
0.003
0.003
1
40
0.004
0.005
2
0.003
0.004
1
50
0.004
0.005
4
0.003
0.004
2
21
17
30
38
34
53
PSD-211
3/2006
Vertical
Horizontal
1/2"
Slot
Width
4' Length
8" Inlet
Vertical
Horizontal
PSD
5' Length
10" Inlet
Vertical
Horizontal
2' Length
8" Inlet
Vertical
Horizontal
3/4"
Slot
Width
4' Length
8" Inlet
Vertical
Horizontal
5' Length
10" Inlet
Vertical
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
10
20
0.005
0.005
2
0.005
0.005
0
40
0.005
0.006
2
0.005
0.006
1
50
0.005
0.006
3
0.005
0.005
1
20
0.004
0.004
2
0.003
0.004
0
40
0.004
0.005
3
0.003
0.004
1
50
0.003
0.004
3
0.003
0.004
1
15
30
0.012
0.012
2
0.011
0.011
1
60
0.011
0.014
3
0.010
0.012
1
75
0.011
0.013
4
0.010
0.012
2
30
0.008
0.009
2
0.008
0.008
1
60
0.008
0.010
4
0.008
0.010
1
75
0.008
0.009
4
0.007
0.009
2
25
50
0.032
0.034
4
<10
0.029
0.031
2
<10
100
0.032
0.038
5
<10
0.029
0.035
3
<10
125
0.031
0.036
6
<10
0.028
0.033
5
<10
50
0.023
0.025
4
0.021
0.023
2
100
0.023
0.028
7
<10
0.021
0.027
3
125
0.022
0.026
6
<10
0.020
0.025
5
11
13
10
13
13
10
40
80
0.083
0.086
6
15
0.075
0.079
5
14
160
0.081
0.096
9
18
0.074
0.088
7
17
200
0.079
0.091
10
20
0.072
0.084
8
19
80
0.059
0.063
6
<10
0.054
0.058
5
<10
160
0.058
0.073
11
14
0.053
0.068
6
<10
200
0.056
0.067
10
16
0.051
0.063
8
<10
13
18
13
21
16
12
20
13
21
15
CFM/LF
60
120
0.186
0.195
6 9 17
26
0.169
0.177
5 7 14
26
240
0.183
0.216
9 13 24
29
0.165
0.199
7 10 20
29
300
0.179
0.206
10 16 27
31
0.162
0.189
8 12 24
31
120
0.133
0.141
6 9 17
20
0.122
0.131
5 7 14
17
240
0.130
0.164
11 16 24
23
0.120
0.154
6 10 19
20
300
0.125
0.152
10 15 27
25
0.115
0.142
8 12 23
22
11
13
10
13
13
10
75
150
0.291
0.304
12
32
0.264
0.277
9
33
300
0.285
0.338
16
35
0.258
0.311
12
36
375
0.279
0.321
19
37
0.253
0.295
15
38
150
0.208
0.221
11
26
0.191
0.204
9
26
300
0.204
0.256
19
29
0.188
0.240
12
29
375
0.196
0.237
19
31
0.180
0.222
15
31
PSD-212
19
17
27 13
24 10
30 16
31 12
19
17
27 16
24 10
30 15
29 12
90
180
0.419
0.438
14
37
0.380
0.398
10
37
360
0.411
0.486
20
40
0.372
0.448
15
40
450
0.402
0.463
23
42
0.365
0.425
18
42
180
0.299
0.318
14
31
0.275
0.294
10
31
360
0.293
0.369
21
34
0.270
0.346
14
34
450
0.282
0.342
23
36
0.259
0.319
17
36
21
13
21
30
18
29
13
33
21
37
16
21
12
21
30
20
29
13
33
21
35
15
120
240
0.745
0.778
17
43
0.675
0.708
14
44
480
0.730
0.864
24
46
0.662
0.796
20
47
600
0.715
0.822
27
48
0.648
0.755
24
49
240
0.532
0.565
17
38
0.490
0.523
14
37
480
0.521
0.656
24
41
0.480
0.614
19
40
600
0.501
0.607
27
43
0.461
0.568
23
42
24 16
28 12
34 23
39 17
38 25
49 22
24 16
27 12
34 23
38 17
38 25
46 21
160
320
1.324
1.383
20
51
1.200
1.259
19
51
640
1.298
1.536
28
54
1.176
1.415
26
54
800
1.272
1.462
31
56
1.153
1.343
33
56
320
0.946
1.005
20
44
0.871
0.930
18
42
640
0.927
1.165
28
47
0.854
1.092
25
45
800
0.890
1.080
31
49
0.819
1.009
31
47
28
37
39
52
44
65
28
37
39
51
44
62
3/2006
Vertical
Horizontal
1"
Slot
Width
4' Length
8" Inlet
Vertical
Horizontal
5' Length
10" Inlet
Vertical
Horizontal
2' Length
8" Inlet
Vertical
Horizontal
1-1/2"
Slot
Width
4' Length
10" Inlet
Vertical
Horizontal
5' Length
12" Inlet
Vertical
25
50
0.014
0.015
4
0.013
0.015
1
100
0.014
0.019
5
0.013
0.019
2
125
0.013
0.018
6
<10
0.013
0.017
2
50
0.007
0.008
3
0.006
0.007
0
100
0.007
0.010
6
0.005
0.008
1
125
0.006
0.009
6
<10
0.005
0.008
1
11
12
12
12
40
80
0.035
0.039
6
<10
0.034
0.038
3
<10
160
0.035
0.050
9
<10
0.033
0.048
4
<10
200
0.034
0.046
10
11
0.032
0.044
5
<10
80
0.018
0.021
5
<10
0.014
0.018
1
160
0.017
0.025
9
<10
0.014
0.022
1
200
0.016
0.024
9
11
0.014
0.021
2
<10
12
17
20
11
11
19
19
CFM/LF
60
120
0.080
0.088
6 9 17
17
0.077
0.085
3 5
9
16
240
0.078
0.112
9 13 24
20
0.075
0.109
4 7 13
19
300
0.076
0.102
10 15 27
22
0.073
0.100
5 8 16
21
120
0.040
0.048
5 8 16
12
0.033
0.041
1 3
7
<10
240
0.039
0.056
9 14 24
15
0.032
0.049
1 3
9
<10
300
0.037
0.053
9 14 27
17
0.030
0.047
2 6 12
11
11
12
12
12
75
150
0.124
0.137
11
24
0.120
0.133
6
24
300
0.122
0.174
16
27
0.117
0.170
8
27
375
0.118
0.160
18
29
0.114
0.156
10
29
150
0.062
0.075
10
17
0.051
0.064
4
10
300
0.060
0.087
17
20
0.049
0.076
5
13
375
0.058
0.083
18
22
0.047
0.073
7
15
19
12
27
13
16
30
15
20
19
27
14
11
30
14
15
90
180
0.179
0.198
13
29
0.172
0.191
7
30
360
0.176
0.251
19
32
0.169
0.244
10
33
450
0.170
0.230
22
34
0.164
0.224
12
35
180
0.089
0.108
12
21
0.073
0.092
5
15
360
0.087
0.125
21
24
0.071
0.110
7
18
450
0.083
0.120
21
26
0.068
0.105
9
20
21
12
14
30
17
20
33
20
24
11
21
11
10
30
19
14
33
19
18
120
240
0.318
0.352
17
35
0.306
0.340
9
37
480
0.312
0.446
24
38
0.300
0.435
13
40
600
0.303
0.410
27
40
0.291
0.398
16
42
240
0.159
0.192
16
29
0.130
0.164
7
23
480
0.154
0.223
24
32
0.127
0.195
9
26
600
0.148
0.213
27
34
0.122
0.186
12
28
24
15
19
34
23
26
12
38
25
32
14
24
14
13
34
23
18
38
25
23
10
160
320
0.566
0.626
20
40
0.545
0.604
12
42
640
0.555
0.793
28
43
0.534
0.772
18
45
800
0.538
0.728
31
45
0.518
0.708
21
47
320
0.282
0.342
20
37
0.232
0.291
9
30
640
0.274
0.396
28
40
0.225
0.347
12
33
800
0.263
0.378
31
42
0.216
0.331
16
35
28
25
39
35
44
43
2' Length
8" Inlet
15
30
0.005
0.005
2
0.005
0.005
0
60
0.005
0.007
3
0.005
0.007
1
75
0.005
0.006
4
0.005
0.006
1
30
0.002
0.003
2
0.002
0.003
0
60
0.002
0.003
3
0.002
0.003
0
75
0.002
0.003
4
0.002
0.003
0
PSD
Horizontal
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
10
20
0.002
0.002
1
0.002
0.002
0
40
0.002
0.003
2
0.002
0.003
0
50
0.002
0.003
2
0.002
0.003
0
20
0.001
0.001
1
0.001
0.001
0
40
0.001
0.002
2
0.001
0.001
0
50
0.001
0.001
2
0.001
0.001
0
28
18
39
20
44
31
PSD-213
3/2006
Vertical
Horizontal
1/2"
Slot
Width
4' Length
8" Inlet
Vertical
Horizontal
PSD
5' Length
10" Inlet
Vertical
Horizontal
2' Length
8" Inlet
Vertical
Horizontal
3/4"
Slot
Width
4' Length
10" Inlet
Vertical
Horizontal
5' Length
10" Inlet
Vertical
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
25
50
0.012
0.013
6
0.009
0.010
1
100
0.012
0.017
6
<10
0.009
0.015
1
125
0.011
0.016
6
<10
0.009
0.013
1
50
0.008
0.010
5
0.006
0.008
0
100
0.008
0.011
7
0.006
0.009
2
125
0.008
0.013
8
<10
0.006
0.011
3
12
12
13
15
17
10
40
80
0.030
0.034
9
<10
0.023
0.027
2
<10
160
0.030
0.044
9
11
0.023
0.037
3
<10
200
0.029
0.041
10
13
0.022
0.034
3
<10
80
0.022
0.025
8
0.016
0.020
1
160
0.021
0.029
12
<10
0.016
0.024
5
<10
200
0.021
0.033
13
10
0.016
0.028
7
<10
15
19
10
20 10
12
15
21 12
13
24 13
16
60
120
0.068
0.076
13
16
0.052
0.060
4
11
240
0.067
0.100
14
19
0.051
0.084
6
14
300
0.065
0.092
15
21
0.050
0.077
7
16
120
0.049
0.057
11
<10
0.037
0.045
3
<10
240
0.048
0.065
18
15
0.036
0.053
10
11
300
0.047
0.074
20
17
0.036
0.062
12
13
19
12
11
26
13
15
29
13
18
19
10
26
16
19
29
18
23
10
80
160
0.121
0.136
15
23
0.092
0.107
7
20
320
0.118
0.178
19
26
0.090
0.150
10
23
400
0.116
0.163
20
28
0.089
0.136
12
25
160
0.087
0.101
15
18
0.066
0.081
5
18
320
0.085
0.115
21
21
0.065
0.095
13
21
400
0.083
0.131
24
23
0.063
0.111
16
23
21
15
30
21
34
24
21
13
30
25
34
27
CFM/LF
100
200
0.188
0.212
14 17 24
29
0.144
0.167
5 9 18
26
400
0.185
0.278
16 24 34
32
0.141
0.234
7 13 26
29
500
0.181
0.255
17 25 38
34
0.138
0.213
9 15 30
31
200
0.135
0.159
13 17 24
23
0.103
0.126
3 7 16
26
400
0.133
0.180
19 24 34
26
0.101
0.148
11 16 27
29
500
0.130
0.204
22 27 38
28
0.099
0.173
13 19 31
31
15
19
10
20
12
15
21
13
24
16
120
240
0.271
0.305
19
34
0.207
0.241
11
31
480
0.266
0.400
26
37
0.203
0.337
15
34
600
0.261
0.368
29
39
0.199
0.306
18
36
240
0.195
0.228
19
27
0.148
0.182
9
33
480
0.191
0.259
26
30
0.145
0.214
19
36
600
0.187
0.294
29
32
0.142
0.249
23
38
PSD-214
26
18
21
10
37
25
30
14
42
27
34
16
26
18
19
37
25
30
17
42
28
34
21
160
320
0.483
0.542
21
41
0.368
0.428
15
36
640
0.473
0.712
30
44
0.361
0.600
21
39
800
0.464
0.654
34
46
0.354
0.544
24
41
320
0.346
0.406
21
34
0.263
0.323
13
41
640
0.339
0.461
30
37
0.258
0.380
25
44
800
0.333
0.523
34
39
0.253
0.443
27
46
30 20
25 12
43 28
35 17
48 31
39 21
30 20
25 10
43 28
35 21
48 31
39 25
200
400
0.754
0.847
24
48
0.576
0.669
18
40
800
0.739
1.112
34
51
0.564
0.937
26
43
1000
0.724
1.021
38
53
0.553
0.850
31
45
400
0.541
0.634
24
40
0.411
0.504
16
47
800
0.530
0.720
34
43
0.403
0.593
27
50
1000
0.520
0.817
38
45
0.395
0.692
31
52
34
22
27
15
48
31
39
21
54
35
43
25
34
22
27
13
48
31
39
25
54
35
43
28
250
500
1.178
1.324
27
55
0.900
1.045
22
46
1000
1.155
1.737
38
58
0.882
1.464
31
49
1250
1.132
1.596
42
60
0.864
1.328
34
51
500
0.845
0.991
27
45
0.643
0.788
20
53
1000
0.829
1.126
38
48
0.630
0.927
31
56
1250
0.812
1.276
42
50
0.617
1.081
34
58
38
31
54
43
60
49
38
31
54
43
60
49
3/2006
Vertical
Horizontal
1"
Slot
Width
4' Length
10" Inlet
Vertical
Horizontal
5' Length
12" Inlet
Vertical
Horizontal
2' Length
10" Inlet
Vertical
Horizontal
1-1/2"
Slot
Width
4' Length
12" Inlet
Vertical
Horizontal
5' Length
12" Inlet
Vertical
10
11
13
16
18
10
11
14
60
120
0.029
0.033
10
<10
0.022
0.026
2
<10
240
0.029
0.046
12
11
0.022
0.039
4
<10
300
0.028
0.044
13
13
0.021
0.038
7
12
120
0.015
0.019
7
<10
0.011
0.015
2
240
0.014
0.025
8
<10
0.011
0.021
3
300
0.014
0.030
11
12
0.011
0.027
4
19
24
11
11
26
12
14
15
16
22
10
80
160
0.052
0.060
13
17
0.039
0.047
4
14
320
0.051
0.081
16
20
0.039
0.069
7
17
400
0.050
0.079
18
22
0.038
0.067
9
19
160
0.026
0.034
10
11
0.020
0.027
3
320
0.025
0.044
11
14
0.019
0.038
4
400
0.025
0.054
14
16
0.019
0.048
6
<10
21
30
14
34
19
20
22
29
11
CFM/LF
100
200
0.081
0.093
11 16 24
25
0.062
0.074
3 6 11
21
400
0.080
0.127
13 20 34
28
0.060
0.108
5 9 18
24
500
0.078
0.123
15 22 38
30
0.059
0.104
8 12 24
26
200
0.041
0.052
8 12 24
15
0.031
0.043
2 4
7
400
0.040
0.069
9 14 27
18
0.030
0.059
3 5 11
<10
500
0.039
0.084
12 18 36
20
0.030
0.075
5 7 14
11
13
16
18
10
11
14
120
240
0.117
0.134
19
31
0.089
0.106
7
27
480
0.115
0.183
24
34
0.087
0.156
11
30
600
0.112
0.177
26
36
0.085
0.150
14
32
240
0.058
0.076
15
19
0.044
0.062
4
<10
480
0.057
0.099
16
22
0.044
0.085
6
13
600
0.056
0.121
22
24
0.043
0.107
9
15
26 17
14
37 21
21
42 24
28 13
26 13
32 14
13
42 19
17
160
320
0.208
0.238
21
39
0.158
0.188
9
35
640
0.204
0.325
30
42
0.155
0.276
14
38
800
0.200
0.315
34
44
0.152
0.267
19
40
320
0.104
0.134
20
27
0.079
0.109
6
16
640
0.102
0.175
22
30
0.077
0.151
9
19
800
0.100
0.215
29
32
0.076
0.191
11
21
30
20
18
43
27
28
12
48
29
38
16
30
16
12
43
18
17
48
24
23
200
400
0.325
0.372
24
46
0.247
0.294
11
41
800
0.318
0.508
34
49
0.242
0.432
18
44
1000
0.312
0.492
38
51
0.237
0.417
24
46
400
0.162
0.210
24
33
0.123
0.171
7
20
800
0.159
0.274
27
36
0.121
0.236
11
23
1000
0.156
0.336
36
38
0.119
0.298
14
25
34 22
23 10
48 31
36 15
54 35
43 20
34 21
15
48 23
22
54 30
28 12
250
500
0.507
0.581
27
54
0.386
0.460
14
45
1000
0.497
0.794
38
57
0.378
0.675
22
48
1250
0.487
0.768
42
59
0.370
0.651
29
50
500
0.254
0.328
27
40
0.193
0.267
9
24
1000
0.249
0.428
34
43
0.189
0.369
14
27
1250
0.244
0.524
42
45
0.185
0.466
18
29
38
29
54
43
60
49
2' Length
10" Inlet
40
80
0.013
0.015
7
0.010
0.012
1
160
0.013
0.020
8
<10
0.010
0.017
2
200
0.012
0.020
9
<10
0.009
0.017
3
<10
80
0.006
0.008
5
0.005
0.007
1
160
0.006
0.011
5
0.005
0.009
1
200
0.006
0.013
7
<10
0.005
0.012
2
PSD
Horizontal
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
Ps
Pt
Throw
NC
25
50
0.005
0.006
4
0.004
0.005
0
100
0.005
0.008
5
0.004
0.007
1
125
0.005
0.008
6
0.004
0.007
1
50
0.003
0.003
3
0.002
0.003
0
100
0.002
0.004
3
0.002
0.004
0
125
0.002
0.005
4
0.002
0.005
1
38
18
27
60
35
PSD-215
3/2006
Vertical
Horizontal
1/2"
Slot
Width
4' Length
10" Inlet
Vertical
Horizontal
PSD
5' Length
10" Inlet
Vertical
Horizontal
2' Length
8" Inlet
Vertical
Horizontal
3/4"
Slot
Width
4' Length
10" Inlet
Vertical
Horizontal
5' Length
10" Inlet
Vertical
CFM
Ps
Pt
Throw 9
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 12
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 13
NC
Ps
Pt
Throw 2
NC
CFM
Ps
Pt
Throw 9
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 6
NC
Ps
Pt
Throw 2
NC
CFM
Ps
Pt
Throw 15
NC
Ps
Pt
Throw 4
NC
50
100
0.033
0.039
12
<10
0.029
0.035
2
<10
200
0.032
0.044
16
<10
0.029
0.040
3
<10
250
0.031
0.050
18
11
0.028
0.047
4
12
100
0.025
0.031
12
0.025
0.031
1
200
0.025
0.037
12
<10
0.025
0.037
5
<10
250
0.024
0.043
18
<10
0.024
0.043
8
<10
16
12
23
16
11
26
18
13
16
12
23
12
13
26
18
16
75
150
0.074
0.087
14
15
0.066
0.079
5
12
300
0.072
0.099
20
18
0.064
0.091
7
15
375
0.071
0.113
22
20
0.063
0.105
9
17
150
0.057
0.070
14
0.057
0.070
3
300
0.056
0.083
19
14
0.056
0.082
10
10
375
0.055
0.097
22
16
0.055
0.096
12
12
20 12
12
28 17
16
31 19
19
20 12
10
28 13
20
31 19
22
80
160
0.084
0.099
15
17
0.075
0.090
5
13
320
0.082
0.113
21
20
0.073
0.104
8
16
400
0.081
0.128
23
22
0.072
0.119
10
18
160
0.065
0.080
15
<10
0.065
0.080
3
<10
320
0.064
0.094
20
15
0.063
0.094
11
12
400
0.062
0.110
23
17
0.062
0.110
13
14
21
13
12
29
19
17
33
21
21
21
13
11
29
17
20
33
21
23
11
100
200
0.131
0.154
16
23
0.117
0.140
8
20
400
0.129
0.176
23
26
0.114
0.162
11
23
500
0.126
0.200
26
28
0.112
0.186
13
25
200
0.101
0.125
16
18
0.101
0.124
5
16
400
0.099
0.147
23
21
0.099
0.147
13
19
500
0.097
0.172
26
23
0.097
0.171
16
21
23
16
33
22
36
25
23
13
33
23
36
25
CFM/LF
150
300
0.295
0.347
16 20 28
35
0.262
0.315
8 12 20
32
600
0.289
0.396
23 28 40
38
0.257
0.364
11 16 28
35
750
0.283
0.450
26 31 45
40
0.252
0.419
13 19 31
37
300
0.228
0.281
16 20 28
29
0.227
0.280
5 10 20
29
600
0.224
0.331
23 28 40
32
0.223
0.330
13 20 28
32
750
0.219
0.386
26 31 45
34
0.219
0.386
16 22 31
34
18
25
13
28
15
18
25
16
28
19
175
350
0.401
0.473
22
39
0.357
0.428
14
36
700
0.394
0.539
30
42
0.350
0.496
19
39
875
0.386
0.613
34
44
0.343
0.570
22
41
350
0.311
0.382
22
33
0.310
0.381
12
33
700
0.305
0.450
30
36
0.304
0.449
21
36
875
0.299
0.526
34
38
0.297
0.525
24
38
PSD-216
30
19
21
10
43
27
30
15
48
30
33
17
30
19
21
43
27
30
18
48
30
33
21
200
400
0.524
0.617
23
42
0.466
0.559
16
39
800
0.514
0.704
33
45
0.457
0.647
22
42
1000
0.504
0.801
36
47
0.448
0.745
25
44
400
0.406
0.499
23
36
0.404
0.498
13
37
800
0.398
0.588
33
39
0.396
0.587
23
40
1000
0.390
0.687
36
41
0.389
0.686
25
42
33
21
23
13
46
30
32
18
51
33
36
21
33
21
23
11
46
30
32
21
51
33
36
23
250
500
0.819
0.965
26
48
0.729
0.874
18
44
1000
0.803
1.100
36
51
0.714
1.011
25
47
1250
0.787
1.251
41
53
0.700
1.164
28
49
500
0.634
0.780
26
42
0.632
0.777
17
41
1000
0.622
0.919
36
45
0.620
0.917
25
44
1250
0.609
1.073
41
47
0.607
1.071
28
46
36
25
51
36
58
40
36 23
25 13
51 33
36 23
58 36
40 25
300
600
0.913
1.123
28
46
0.910
1.119
20
44
1200
0.895
1.323
40
49
0.892
1.320
28
47
1500
0.877
1.546
45
51
0.874
1.543
31
49
40
28
56
39
63
44
3/2006
Vertical
Horizontal
1"
Slot
Width
4' Length
10" Inlet
Vertical
Horizontal
5' Length
12" Inlet
Vertical
Horizontal
2 ' Length
10" Inlet
Vertical
Horizontal
1-1/2"
Slot
Width
4' Length
12" Inlet
Vertical
Horizontal
5' Length
12" Inlet
Vertical
16
12
23
16
26
17
12
16
10
21
26
14
20 12
28 17
13
31 18
18
20 10
28 10
31 15
80
160
0.045
0.052
15
<10
0.042
0.050
4
<10
320
0.044
0.074
21
13
0.042
0.072
7
<10
400
0.043
0.072
23
15
0.041
0.069
9
12
160
0.042
0.050
15
<10
0.032
0.039
2
320
0.041
0.060
17
<10
0.031
0.050
3
400
0.041
0.069
22
12
0.030
0.059
5
21
13
29
19
14
33
21
19
21
13
29
14
33
19
100
200
0.070
0.082
16
16
0.066
0.078
6
13
400
0.068
0.116
23
19
0.065
0.112
9
16
500
0.067
0.112
26
21
0.064
0.109
12
18
200
0.066
0.078
16
10
0.050
0.061
3
<10
400
0.065
0.093
21
13
0.049
0.077
4
<10
500
0.063
0.108
26
15
0.048
0.093
6
<10
23
11
33
18
36
24
23
33
36
11
CFM/LF
150
300
0.157
0.183
16 20 28
29
0.149
0.176
6 9 17
26
600
0.154
0.261
23 28 40
32
0.146
0.253
9 13 27
29
750
0.151
0.252
26 31 45
34
0.143
0.244
12 18 31
31
300
0.148
0.175
16 20 28
19
0.112
0.138
3 4
9
12
600
0.145
0.210
21 28 40
22
0.109
0.174
4 6 13
15
750
0.142
0.244
26 31 45
24
0.107
0.208
6 9 17
17
18
25
10
28
14
18
25
28
175
350
0.213
0.250
22
33
0.203
0.239
10
31
700
0.209
0.355
30
36
0.199
0.344
16
34
875
0.205
0.343
34
38
0.195
0.332
21
36
350
0.202
0.238
22
23
0.152
0.188
5
17
700
0.198
0.286
30
26
0.149
0.237
8
20
875
0.194
0.331
34
28
0.146
0.283
10
22
30 19
20
43 27
30 12
48 30
33 16
30 19
10
43 27
15
48 30
20
200
400
0.279
0.326
23
36
0.265
0.312
11
34
800
0.273
0.463
33
39
0.260
0.450
18
37
1000
0.268
0.447
36
41
0.254
0.434
24
39
400
0.264
0.311
23
27
0.198
0.246
6
21
800
0.258
0.373
33
30
0.194
0.309
9
24
1000
0.253
0.433
36
32
0.191
0.370
11
26
33 21
23 10
46 30
32 15
51 33
36 20
33 21
12
46 30
17
51 33
23
250
500
0.435
0.510
26
41
0.414
0.488
14
39
1000
0.427
0.724
36
44
0.406
0.703
22
42
1250
0.418
0.699
41
46
0.398
0.678
28
44
500
0.412
0.486
26
33
0.310
0.384
7
27
1000
0.404
0.583
36
36
0.304
0.483
11
30
1250
0.396
0.676
41
38
0.298
0.578
14
32
36 23
25
11
51 33
36 18
58 36
40 24
36 23
15
51 33
22
58 36
28
11
300
600
0.627
0.734
28
44
0.596
0.703
17
43
1200
0.615
1.042
40
47
0.584
1.012
27
46
1500
0.602
1.007
45
49
0.572
0.977
31
48
600
0.593
0.700
28
38
0.446
0.553
9
31
1200
0.581
0.840
40
41
0.437
0.696
13
34
1500
0.570
0.974
45
43
0.429
0.833
17
36
40
28
56
39
63
2' Length
10" Inlet
75
150
0.039
0.046
14
0.037
0.044
3
300
0.038
0.065
20
11
0.037
0.063
6
375
0.038
0.063
22
13
0.036
0.061
9
10
150
0.037
0.044
14
0.028
0.035
2
300
0.036
0.053
16
0.027
0.044
3
375
0.036
0.061
21
11
0.027
0.052
4
44
PSD
Horizontal
CFM
Ps
Pt
Throw 8
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 11
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 11
NC
Ps
Pt
Throw 2
NC
CFM
Ps
Pt
Throw 6
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 4
NC
Ps
Pt
Throw 1
NC
CFM
Ps
Pt
Throw 7
NC
Ps
Pt
Throw 1
NC
50
100
0.017
0.020
12
0.017
0.020
2
200
0.017
0.029
16
<10
0.016
0.028
3
250
0.017
0.028
17
<10
0.016
0.027
5
<10
100
0.016
0.019
10
0.012
0.015
1
200
0.016
0.023
8
0.012
0.019
2
250
0.016
0.027
14
<10
0.012
0.023
3
40
18
56
26
63
34
Performance Notes:
All data are tested in accordance with ANSI/ASHRAE 70-1991
Definition of Units:
CFM
- Cubic feet per minute (air)
Pt
- Total pressure (inches of water column)
Ps
- Static pressure = Pt - Pv (inches of water column)
Throw - Isothermal horizontal throw (supply air temperature the same as average room air temperature) values are for 150 fpm - 100 fpm - 50 fpm velocities
NC
- Noise criterion, sound pressure level. NC ratings are based on sound power level (Lw) RE: 10E-12 watts minus a 10 dB room attenuation in all octave bands
Two-way throw can be determined by dividing the supply air volume in each direction and using the One-way throw values listed. (See example below)
EXAMPLE:
PHPS-10-6, 10" inlet 1" Slot, 4-Slot, 4', 2-Way
Determine Ps, NC, and Throw at 600 CFM
1. Find Ps and NC using PHPS-10-6, 1" Slot, 4', 4-Slot data:
Ps = .154
NC = 32
For 2-way throw use PHPS-10-6, 1" Slot, 4', 10" inlet, 1-way, 2-Slot data at 300 CFM.
Horizontal Throw = 11-16-27 in each direction
PSD-217
3/2006
2 Slot
3 Slot
4 Slot
1 Slot
1/2"
Slot
Width
4'
Length
2 Slot
3 Slot
4 Slot
1 Slot
5'
Length
2 Slot
3 Slot
PSD
4 Slot
1 Slot
2'
Length
2 Slot
3 Slot
4 Slot
1 Slot
3/4"
Slot
Width
4'
Length
2 Slot
3 Slot
4 Slot
1 Slot
5'
Length
2 Slot
3 Slot
4 Slot
PSD-218
Negative Ps
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Negative Ps
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
10
0.016
20
<15
40
<15
60
<15
80
<15
40
<15
80
<15
120
<15
160
<15
50
<15
100
<15
150
<15
200
<15
15
0.032
30
<15
60
<15
90
<15
120
<15
60
<15
120
<15
180
<15
240
<15
75
<15
150
<15
225
<15
300
<15
20
0.052
40
<15
80
<15
120
<15
160
<15
80
<15
160
<15
240
<15
320
15
100
<15
200
<15
300
15
400
16
25
0.076
50
<15
100
15
150
16
200
18
100
<15
200
17
300
18
400
20
125
15
250
18
375
19
500
21
CFM/LF
30
0.103
60
16
120
19
180
21
240
22
120
18
240
21
360
23
480
24
150
19
300
22
450
24
600
25
35
0.134
70
20
140
23
210
25
280
26
140
22
280
25
420
27
560
28
175
23
350
26
525
28
700
29
40
0.168
80
24
160
27
240
29
320
30
160
26
320
29
480
31
640
32
200
27
400
30
600
32
800
33
45
0.206
90
28
180
31
270
33
360
34
180
30
360
33
540
35
720
36
225
31
450
34
675
36
900
37
50
0.246
100
32
200
35
300
36
400
38
200
34
400
37
600
38
800
40
250
35
500
38
750
39
1000
41
10
0.012
20
<15
40
<15
60
<15
80
<15
40
<15
80
<15
120
<15
160
<15
50
<15
100
<15
150
<15
200
<15
15
0.024
30
<15
60
<15
90
<15
120
<15
60
<15
120
<15
180
<15
240
<15
75
<15
150
<15
225
<15
300
<15
20
0.040
40
<15
80
<15
120
<15
160
<15
80
<15
160
<15
240
<15
320
<15
100
<15
200
<15
300
<15
400
<15
25
0.058
50
<15
100
<15
150
<15
200
<15
100
<15
200
<15
300
<15
400
15
125
<15
250
<15
375
15
500
16
CFM/LF
30
0.079
60
<15
120
<15
180
15
240
17
120
<15
240
16
360
17
480
19
150
<15
300
17
450
18
600
20
40
0.129
80
17
160
20
240
22
320
23
160
19
320
22
480
24
640
25
200
20
400
23
600
25
800
26
50
0.189
100
24
200
27
300
28
400
30
200
26
400
29
600
30
800
32
250
27
500
30
750
31
1000
33
60
0.257
120
29
240
32
360
34
480
35
240
31
480
34
720
36
960
37
300
32
600
35
900
37
1200
38
70
0.334
140
35
280
38
420
39
560
41
280
37
560
40
840
41
1120
43
350
38
700
41
1050
42
1400
44
3/2006
2'
Length
2 Slot
3 Slot
4 Slot
1 Slot
1"
Slot
Width
4'
Length
2 Slot
3 Slot
4 Slot
1 Slot
5'
Length
2 Slot
3 Slot
4 Slot
1 Slot
2'
Length
2 Slot
3 Slot
4 Slot
1 Slot
1-1/2"
Slot
Width
2 Slot
4'
Length
3 Slot
4 Slot
1 Slot
5'
Length
2 Slot
3 Slot
4 Slot
30
0.045
60
<15
120
<15
180
<15
240
<15
120
<15
240
<15
360
<15
480
<15
150
<15
300
<15
450
<15
600
15
40
0.073
80
<15
160
<15
240
15
320
16
160
<15
320
15
480
17
640
18
200
<15
400
16
600
18
800
19
50
0.106
100
15
200
18
300
19
400
21
200
17
400
20
600
21
800
23
250
18
500
21
750
22
1000
24
CFM/LF
60
0.145
120
19
240
22
360
23
480
25
240
21
480
24
720
25
960
27
300
22
600
25
900
26
1200
28
70
0.188
140
23
280
26
420
27
560
29
280
25
560
28
840
29
1120
31
350
26
700
29
1050
30
1400
32
80
0.236
160
26
320
29
480
31
640
32
320
28
640
31
960
33
1280
34
400
29
800
32
1200
34
1600
35
90
0.289
180
30
360
33
540
35
720
36
360
32
720
35
1080
37
1440
38
450
33
900
36
1350
38
1800
39
100
0.345
200
34
400
37
600
38
800
40
400
36
800
39
1200
40
1600
42
500
37
1000
40
1500
41
2000
43
Negative Ps
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
20
0.011
40
<15
80
<15
120
<15
160
<15
80
<15
160
<15
240
<15
320
<15
100
<15
200
<15
300
<15
400
<15
30
0.022
60
<15
120
<15
180
<15
240
<15
120
<15
240
<15
360
<15
480
<15
150
<15
300
<15
450
<15
600
<15
40
0.036
80
<15
160
<15
240
<15
320
<15
160
<15
320
<15
480
<15
640
15
200
<15
400
<15
600
<15
800
16
50
0.053
100
<15
200
<15
300
15
400
17
200
<15
400
16
600
17
800
19
250
<15
500
17
750
18
1000
20
CFM/LF
60
0.072
120
<15
240
17
360
19
480
20
240
16
480
19
720
21
960
22
300
17
600
20
900
22
1200
23
80
0.117
160
22
320
25
480
26
640
28
320
24
640
27
960
28
1280
30
400
25
800
28
1200
29
1600
31
100
0.171
200
28
400
31
600
33
800
34
400
30
800
33
1200
35
1600
36
500
31
1000
34
1500
36
2000
37
125
0.250
250
36
500
39
750
40
1000
42
500
38
1000
41
1500
42
2000
44
625
39
1250
42
1875
43
2500
45
150
0.341
300
42
600
45
900
47
1200
48
600
44
1200
47
1800
49
2400
50
750
45
1500
48
2250
50
3000
51
PSD
1 Slot
Negative Ps
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
Airflow
NC
20
0.022
40
<15
80
<15
120
<15
160
<15
80
<15
160
<15
240
<15
320
<15
100
<15
200
<15
300
<15
400
<15
PSD-219
3/2006
Inlets shall be round or oval, centrally located, with a minimum depth of 2 1/8" for ease of duct connection. Units with inlet depths less than 1-3/4" are not
acceptable. For straightness and rigidity, plenums shall be fabricated using a singlepiece panel construction and have a double metal thickness hem at the
face. Plenum diffusers shall be constructed of corrosion resistant galvanized steel. Height of unit shall be 10" or greater to maximize diffuser performance.
Units with heights less than 10" are not acceptable.
Units shall be available with 1/2", 3/4", 1", or 1-1/2" slot widths and be available with 1, 2, 3, or 4 independent supply slots. Diffuser face and air pattern
controller shall be black. Optional tees shall be white.
Insulated diffusers shall be Model PHPSI. Insulation shall be internal, 1/4" matte face. End caps must be insulated.
PSD
Plenum return units shall be constructed of corrosion resistant galvanized steel. For straightness and rigidity, plenums shall be fabricated using a double
metal thickness hem at the face. Units fabricated without a double metal thickness hem at the face are not acceptable.
Units shall be available with 1/2", 3/4", 1", or 1-1/2" slot widths and be available with 1, 2, 3, or 4 independent supply slots. Diffuser face shall be black.
Optional tees shall be white.
PSD-220
3/2006
Plenum slot supply diffusers shall be METALAIRE PHNS9 (noninsulated) or PHNSI9 (insulated). Plenum slot diffusers shall be of the sizes and
mounting types as shown on the device schedule.
Units shall be designed to integrate into 9/16" wide bolt slot or narrow tee systems and include a center hat channel to fit over ceiling tee (by others) on
two-slot units. Diffusers shall have aluminum extruded deflector blades with a gasket tip to seal against the plenum side wall or slot divider. Units shall be
adjustable from the slot opening to provide horizontal to vertical air patterns.
Inlets shall be round or oval, centrally located, with a minimum depth of 2 1/8" for ease of duct connection. Units with inlet depths less than
1-3/4" are not acceptable. For straightness and rigidity, plenums shall be fabricated using a singlepiece panel construction and have a double metal
thickness hem at the face. Plenum diffusers shall be constructed of corrosion resistant galvanized steel. Height of unit shall be 10" or greater. Units with
heights less than 10" are not acceptable.
Insulated diffusers shall be Model PHPSI. Insulation shall be internal, 1/4" matte face. End caps must be insulated. Units without insulation on end caps will
not be accepted.
PSD
Units shall be available with 3/4", 1", or 1-1/2" slot widths and be available with 1 or 2 independent supply slots. Diffuser face and air pattern controller
shall be white.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
Performance
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
PSD-221
3/2006
Length
24"
36"
48"
60"
# of Slots
Inlet
Available Finishes
CN
Tee
6" round
Standard
T-1
8" oval
T-2
10" oval
TC-1
12" oval
TC-2
26 - All White
TC-3
27 - All Black
EN
25 - White Tee/
Black Border
Optional
End Notch
EN-2
PSD
PSD-222
Available Options
CN
Cross Notch
LQ
PH-TBPF
3/2006
Length
# of Slots
Inlet
Available Finishes
24"
48"
6" round
Standard
8" oval
10" oval
12" oval
Available Options
LQ
25 - White Tee/
Black Border
Optional
26 - All White
27 - All Black
PSD
PSD-223
High Capacity Plenum Slot Diffusers Fixed Pattern Controller Series PHC
PSD
Product Details
Aerodynamically shaped, heavy duty extruded
aluminum curved blade pattern controller
generates a tight horizontal discharge pattern
1
28
Nominal
Available
Center
Lengths
InletsDown
Air Pattern Deflector
Blow
24
24, 36, 48, 60
11
16
Fixed
Pattern
Controller
60
3
4
Nominal
24, 36, 48,
60 Lengths
24
36
48
60
Adjustable
Pattern
Controller
27
8
Inlet Size
6" Oval
8" Oval
10" Oval
12" Oval
Available Inlets
6, 8, 10, 12
6, 8, 10, 12
6, 8, 10, 12
6, 8, 10, 12
B
3 15/16
3 15/16
3 15/16
3 15/16
r
Blow
14
Fixed
Pattern
Controller
s)
Lengths
24
36
48
60
Available Inlets
6, 8, 10, 12
6, 8, 10, 12
6, 8, 10, 12
6, 8, 10, 12
B
3 15/16
3 15/16
3 15/16
3 15/16
3
4
C
6 15/16
8 15/16
13 15/16
15 15/16
27
8
1
2
11
16
13
8
25
8
3
4
1
2
1
14
PSD-224
13
4
3
4
Air
Inlet
25
8
3
4
1
14
45
8
1
2
2. Available Accessories
LQ - Locking quadrant damper
Inlet Size
C
D
Inlet
6 Round 3 15/16 6 15/16
8 Oval
3
4
3 15/16 8 15/16
Air
Inlet
Fixed
Pattern
Contro
1
28
1
2
- Fixed
Inlet
C
8
11
16
12
Fixed
Pattern
Controller Air Pattern Deflector
12
Inlet
Inlet
27
8
1
2
1
Overall Length = T-Bar Spacing - 4
High Induction Supply/Return Plenum Diffusers - Louver
Face
Spacing
(24, 36, 48,
and 60
Lengths)
Curved Blade - CenterT-Bar
Down
Blow Section
- Front
View
1
45
Overall
Length = T-Bar Spacing - 4
8
1. Available Finishes
3
4
13
8
C
6 15/16
8 15/16
13 15/16
15 15/16
Standard Finish:
Black Borders
1
2
11
16
Fixed
Pattern
Controller
1
Overall Length = T-Bar Spacing - 4
36
24, 36, 48, 60
T-Bar Spacing (24, 36, 48 and 60 Lengths)
48
13
8
Air
Inlet
12
Air
Inlet
1
28
3
4
B
Air
Inlet
3
4
8
11
16
Return -Fixed
High Induction Plenum Diffusers - Fixed Curved Blade
Pattern
Non Insulated
Controller
Model PHCR-6
3 Down Blow
Model PHCR-DB-6 - 34Center
4
Insulated
13
8
Model PHCRI-6
27
8
Model PHCRI-DB-6 - Center Down Blow
1
2
1
2
Air
Inlet
1
28
3
4
s)
e
l
l
3/2006
3
4
B
Center
Down Blow
1
3Overall3Length = T-Bar Spacing - 4
4
4
T-Bar3Spacing (24, 36, 48 and 60 Lengths)
18
27
8 Construction Details
3.
Nominal Lengths
Available Inlets
Extruded aluminum pattern controller 24
6, 8, 10, 12
36 with double 6, 8, 10, 12
One-piece electrogalvanized steel plenum
1
6, 8, 10, 12
hem face
48
2
Adjustable
8
6, 8, 10, 12
60(inlets are round)
3
1 Plenum inlets available in 6", 8", 10", 12"
Pattern
4
2
Controller
C
Inlet Size
B
6 15/16
6" Oval 3 15/16
13
4
8 15/16
8" Oval 3 15/16
at www.metalaire.com
1
10" Oval 3 15/16 13 15/16
2
Air
12" Oval 3 15/16 15 15/16
Inlet
Air
Inlet
Fix
Patte
Controll
3/2006
3' length
6"
Round
Inlet
4' length
5' length
2' length
3' length
8"
Oval
Inlet
4' length
5' length
3' length
10"
Oval
Inlet
4' length
5' length
4' length
12"
Oval
Inlet
5' length
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
20
60
0.008
0.009
2
80
0.010
0.011
3
100
0.011
0.014
4
80
0.008
0.010
3
100
0.010
0.012
4
10
12
30
60
0.022
0.028
5
17
90
0.029
0.042
5
<15
120
0.033
0.056
7
<15
150
0.034
0.071
9
<15
60
0.014
0.017
2
<15
90
0.020
0.025
4
120
0.025
0.033
5
150
0.028
0.041
6
30
90
0.017
0.019
4
120
0.021
0.026
5
150
0.024
0.031
6
120
0.019
0.021
5
150
0.023
0.027
6
11
11
14
18
10
13
10
13
10
12
40
80
0.040
0.050
7
21
120
0.052
0.075
7
16
160
0.059
0.100
10
<15
200
0.061
0.125
12
16
80
0.026
0.029
3
19
120
0.036
0.044
5
<15
160
0.044
0.059
7
<15
200
0.050
0.074
8
<15
40
120
0.030
0.034
5
<15
160
0.038
0.046
7
200
0.043
0.055
8
<15
160
0.033
0.038
6
200
0.040
0.048
8
<15
14
14
19
24
10
14
16
50
100
0.062
0.078
6 9
26
150
0.081
0.117
6 9
22
200
0.092
0.157
8 12
19
250
0.095
0.196
10 15
21
100
0.040
0.046
3 4
24
150
0.056
0.069
4 6
20
200
0.069
0.092
6 8
18
250
0.079
0.115
7 11
20
10
13
15
13
15
50
150
0.047
0.054
6
17
200
0.060
0.072
8
<15
250
0.068
0.086
11
17
200
0.052
0.060
8
<15
250
0.063
0.074
10
16
18
18
24
27
13
16
18
13
15
17
15
17
CFM/LF
60
120
0.089
0.113
7 11 19
31
180
0.117
0.169
7 11 22
27
240
0.132
0.226
10 14 27
25
300
0.137
0.282
12 18 30
27
120
0.058
0.066
3
5 10
28
180
0.081
0.099
5
8 15
25
240
0.099
0.133
7 10 18
23
300
0.113
0.166
8 13 20
26
CFM/LF
60
180
0.068
0.077
5
8 14
22
240
0.086
0.103
7 10 16
20
300
0.097
0.124
8 13 18
23
240
0.075
0.086
6 10 16
18
300
0.091
0.107
8 12 18
21
10
10
13
16
11
11
11
80
160
0.159
0.200
14
39
240
0.208
0.301
14
36
320
0.235
0.401
19
35
400
0.243
0.502
24
36
160
0.103
0.118
7
37
240
0.143
0.177
10
35
320
0.176
0.236
14
33
400
0.201
0.294
16
35
80
240
0.120
0.137
10
31
320
0.153
0.183
13
30
400
0.173
0.221
15
32
320
0.134
0.152
13
28
400
0.162
0.190
15
30
22 11
27 11
31 14
35 18
14
18
20 10
23 13
16
19 10
21 13
19 10
21 12
90
180
0.201
0.254
16
44
270
0.263
0.381
16
41
360
0.298
0.507
22
40
450
0.308
0.635
26
41
180
0.130
0.149
8
41
270
0.181
0.224
11
39
360
0.223
0.299
15
38
450
0.255
0.373
17
38
90
270
0.152
0.174
11
36
360
0.193
0.232
14
35
450
0.219
0.279
16
36
360
0.170
0.193
14
33
450
0.205
0.241
16
34
24
12
28
12
33
16
37
20
15
19
21
11
24
14
17
20
11
23
14
20
11
22
13
100
200
0.248
0.313
18
48
300
0.324
0.470
18
46
400
0.368
0.626
24
44
500
0.380
0.784
27
45
200
0.161
0.184
8
46
300
0.224
0.276
13
44
400
0.275
0.369
16
43
500
0.314
0.460
18
42
100
300
0.188
0.214
13
40
400
0.239
0.286
15
39
500
0.271
0.345
17
40
400
0.209
0.238
15
37
500
0.253
0.298
17
38
25
30
35 18
39
16
20
23 12
25 15
18
21 12
24 14
21 12
23 14
110
440
0.445
0.758
26
49
330
0.271
0.334
14
49
440
0.333
0.446
17
48
550
0.380
0.557
19
46
110
330
0.227
0.260
14
45
440
0.289
0.346
16
44
550
0.328
0.417
18
43
440
0.253
0.288
16
42
550
0.306
0.360
17
41
36
PSD
2' length
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
20
40
0.010
0.013
2
<15
60
0.013
0.019
3
80
0.015
0.025
5
100
0.015
0.031
6
40
0.006
0.007
1
60
0.009
0.011
2
80
0.011
0.015
3
100
0.013
0.018
4
21
24
27
19
22
25
22
25
120
360
0.270
0.309
10 14
50
480
0.344
0.412
13 16
48
600
0.390
0.497
15 18
47
480
0.301
0.343
13 16
46
600
0.364
0.428
15 18
45
20
23
26
23
26
PSD-225
3/2006
PSD
3' length
6"
Round
Inlet
12 x 7/16
Down blow
Slot
4' length
5' length
3' length
8"
Oval
Inlet
12 x 7/16
Down blow
Slot
4' length
5' length
3' length
10"
Oval
Inlet
12 x 7/16
Down blow
Slot
4' length
5' length
12"
Oval
Inlet
18 x 7/16
Down blow
Slot
4' length
5' length
PSD-226
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
CFM
Ps
Pt
Throw, H
Throw, V
NC
1
1
2
1
4
1
1
1
2
1
4
1
1
1
1
1
2
1
1
1
2
1
20
60
0.049
0.055
3
1
19
80
0.052
0.062
6
2
<15
100
0.020
0.037
7
2
60
0.031
0.033
3
1
15
80
0.018
0.022
6
1
<15
100
0.016
0.021
7
2
20
60
0.015
0.016
2
1
<15
80
0.015
0.017
3
1
100
0.014
0.017
5
1
80
0.013
0.014
3
1
100
0.012
0.014
4
1
9
2
3
1
12
3
6
2
15
4
7
2
9
2
3
1
11
3
6
1
14
3
7
2
6
2
2
1
8
2
3
1
9
3
5
1
7
2
3
1
9
3
4
1
30
90
0.111
0.124
7
2
23
120
0.116
0.140
9
2
21
150
0.046
0.082
11
3
<15
90
0.069
0.074
6
2
20
120
0.040
0.048
9
2
17
150
0.035
0.048
11
3
<15
30
90
0.034
0.036
4
1
16
120
0.034
0.038
6
2
<15
150
0.031
0.038
7
2
120
0.029
0.031
5
2
<15
150
0.027
0.031
7
2
13
4
6
2
18
5
8
2
22 10
5 3
13
3
6
1
16
4
8
2
18
4
9
2
8
2
3
1
11
3
5
1
14
4
6
2
11
3
5
1
13
4
6
2
40
120
0.198
0.221
9
2
28
160
0.207
0.248
12
3
27
200
0.081
0.146
15
4
20
120
0.122
0.131
9
2
24
160
0.071
0.086
11
3
23
200
0.063
0.086
14
3
15
40
120
0.060
0.065
6
2
21
160
0.060
0.067
8
2
20
200
0.055
0.067
9
3
<15
160
0.051
0.056
7
2
18
200
0.049
0.056
9
3
<15
18
5
23
5
26
6
16
4
19
4
21
5
50
150
0.309
0.345
7 11
2 3
32
200
0.323
0.388
10 15
3 4
33
250
0.127
0.228
12 19
3 5
27
150
0.191
0.204
7 11
2 3
28
200
0.111
0.134
9 14
2 3
29
250
0.098
0.134
12 17
3 4
23
11
3
5
1
15
4
6
2
19
4
8
2
14
4
6
2
18
4
7
2
50
150
0.094
0.101
7
2
25
200
0.093
0.105
9
3
25
250
0.086
0.105
12
3
21
200
0.080
0.087
9
3
24
250
0.076
0.087
11
3
19
22
5
9
2
26
6
12
3
29
7
15
4
18
4
9
2
21
5
11
3
23
6
14
3
14
4
6
2
19
4
8
2
21
5
9
3
18
4
7
2
21
5
9
3
60
180
0.445
0.497
13
4
36
240
0.465
0.558
18
5
37
300
0.183
0.329
22
5
34
180
0.275
0.294
13
3
33
240
0.160
0.194
16
4
33
300
0.141
0.193
18
4
29
CFM/LF
70
210
0.606
0.677
25 10 16
6 3 4
40
280
0.633
0.760
28 14 21
7 4 5
42
350
0.249
0.447
32 17 24
7 5 6
39
210
0.375
0.400
20 10 15
5 2 4
37
280
0.218
0.264
23 13 18
5 3 4
37
350
0.192
0.263
26 16 20
6 4 5
35
60
180
0.136
0.145
8
2
29
240
0.134
0.151
11
3
30
300
0.124
0.151
14
4
28
240
0.115
0.126
11
3
28
300
0.109
0.125
13
4
26
CFM/LF
70
210
0.185
0.198
17 7 10
4 2 3
33
280
0.182
0.206
21 9 13
5 3 4
34
350
0.169
0.206
23 11 16
5 3 4
34
280
0.157
0.171
20 8 12
5 3 4
32
350
0.149
0.171
23 10 16
5 3 4
32
27 12
6 3
31 16
7 4
34 20
8 5
22 11
5 3
25 15
6 4
28 17
7 4
19
5
8
2
22 10
5 3
25 13
6 4
22 10
5 3
24 12
6 4
80
240
0.791
0.884
18
5
44
320
0.827
0.993
23
5
46
400
0.325
0.584
26
6
44
240
0.489
0.523
16
4
40
320
0.285
0.344
19
4
41
400
0.251
0.344
21
5
40
80
240
0.241
0.258
11
3
37
320
0.238
0.269
15
4
38
400
0.221
0.269
19
4
39
320
0.205
0.223
14
4
36
400
0.194
0.223
18
4
36
28
7
13
4
33
8
18
5
37
8
22
5
23
5
13
3
27
6
16
4
30
7
18
4
21
5
8
2
24
6
11
3
27
6
14
4
23
6
11
3
26
6
13
4
90
270
1.001
1.119
20
5
47
360
1.047
1.256
25
6
49
450
0.412
0.739
28
6
49
270
0.619
0.662
17
4
44
360
0.360
0.436
20
5
45
450
0.317
0.435
22
5
44
90
270
0.305
0.327
13
4
41
360
0.302
0.340
17
4
41
450
0.280
0.340
20
5
43
360
0.259
0.282
16
4
40
450
0.246
0.282
20
5
41
30
7
35
8
39
9
24 14
6 3
28 17
7 4
32 19
8 5
22
5
9
3
25 13
6 4
29 16
7 4
25 12
6 4
28 15
7 4
100
300
0.764
0.817
18
4
47
400
0.445
0.538
21
5
49
500
0.391
0.537
23
6
47
100
300
0.377
0.404
14
4
44
400
0.372
0.420
19
4
45
500
0.345
0.420
21
5
47
400
0.320
0.349
18
4
43
500
0.303
0.348
21
5
45
110
26
6
30
7
33
8
23
5
10
3
27
6
14
4
30
7
26
6
13
4
29
7
16
4
110
330
0.456
0.488
16
4
47
440
0.451
0.508
20
5
49
440
0.387
0.422
19
5
47
550
0.367
0.421
22
5
49
24
6
28
7
27
7
31
7
3/2006
Insulated diffusers shall be model PHCSI-6. Insulation shall be internal, 1/4" matte face. End caps must be insulated. Units without insulation on end caps
will not be accepted.
Plenum slot return diffusers shall be METALAIRE PHCR-6 (non-insulated) or PHCRI-6 (insulated). Plenum slot diffusers shall be of the sizes and mounting
types as shown on the device schedule.
PSD
Plenum diffusers shall include a fixed curved blade supply air section and an integral plenum return section.
The supply section shall have an aerodynamically shaped extruded aluminum curved blade deflector that provides a one way horizontal discharge pattern.
Unit shall have an integral plenum return section designed for plenum return applications. Return section shall include a light shield to minimize reflective
light coming through the slot opening.
Inlets shall be centrally located with a minimum depth of 2 1/8" for ease of duct connection. For straightness and rigidity, plenums shall be fabricated using
a two piece panel construction and have a double metal thickness hem at the face. Units fabricated using single wrapper construction are not acceptable.
Plenum diffusers shall be constructed of corrosion resistant galvanized steel.
Diffuser face and air pattern controller shall be black.
Insulated diffusers shall be model PHCRI-6. Supply section insulation shall be internal 1/4" matte face. End caps on the supply section must be insulated.
Units without insulation on supply section end caps will not be accepted.
Supply - Center Down Blow - T-bar Lay-in - Fixed Curved Blade - Insulated/Non Insulated/Model PHCS(I)-DB-6
Plenum slot supply diffusers shall be METALAIRE PHCS-DB-6 (non-insulated) or PHCSI-DB-6 (insulated). Plenum slot diffusers shall be of the sizes and
mounting types as shown on the device schedule.
Plenum diffusers shall include a fixed curved blade supply air section and a center down-blow section. The supply section shall have an aerodynamically
shaped extruded aluminum curved blade deflector that provides a one way horizontal discharge pattern.
Plenum slot diffusers shall include an integral adjustable center down-blow section that provides a vertical jet of supply air. Volume and direction of
discharge air through center down-blow section shall be adjustable through the face of the diffuser.
Inlets shall be centrally located, with a minimum depth of 2 1/8" for ease of duct connection. For straightness and rigidity, plenums shall be fabricated
using a two piece panel construction and have a double metal thickness hem at the face. Units fabricated using single wrapper construction are not
acceptable. Plenum diffusers shall be constructed of corrosion resistant galvanized steel.
Diffuser face and air pattern controller shall be black.
Insulated diffusers shall be model PHCSI-DB-6. Supply section insulation shall be internal 1/4" matte face. End caps must be insulated. Units without
insulation on end caps will not be accepted.
PSD-227
3/2006
Return - Center Down Blow - T-bar Lay-in - Fixed Curved Blade - Insulated/Non Insulated/Model PHCR(I)-DB-6
Plenum slot return diffusers shall be METALAIRE PHCR-DB-6 (non-insulated) or PHCRI-DB-6 (insulated). Plenum slot diffusers shall be of the sizes and
mounting types as shown on the device schedule.
Plenum diffusers shall include a supply air section, a center down-blow section, and an integral plenum return section. The supply section shall have an
aerodynamically shaped extruded aluminum curved blade deflector that provides a one way horizontal discharge pattern. Plenum slot diffuser shall include
an integral adjustable center down-blow section that provides a vertical jet of supply air. Volume and direction of discharge air through center down-blow
section shall be adjustable through the face of the diffuser. Unit shall also have an integral plenum return section designed for plenum return applications.
Return section shall include a light shield to minimize reflective light coming through the slot opening.
Inlets shall be centrally located, with a minimum depth of 2 1/8" for ease of duct connection. For straightness and rigidity, plenums shall be fabricated
using a two piece panel construction and have a double metal thickness hem at the face. Units fabricated using single wrapper construction are not
acceptable. Plenum diffusers shall be constructed of corrosion resistant galvanized steel.
Diffuser face and air pattern controller shall be black.
Insulated diffusers shall be model PHCRI-DB-6. Supply section insulation shall be internal 1/4" matte face. End caps on the supply section must be
insulated. Units without insulation on supply section end caps will not be accepted.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
PSD
PSD-228
Property
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
Pencil Hardness
ASTM D3363-92A
70-80%
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Length
Supply
PHCS-6 - Non Insulated
PHCSI-6 - Insulated
Center Down Blow Section
PHCS-DB-6 - Non Insulated
24"
36"
48"
60"
Inlet
Available Finishes
6" round
Standard
8" oval
Available Options
LQ
27 - All Black
10" oval
12" oval
PHCSI-DB-6 - Insulated
Return
PSD
PHCRI-DB-6 - Insulated
PSD-229
For more product information visit us at www.metalaire.com
3/2006
Product Details
Architecturally pleasing; Reduces ceiling clutter
by integrating the ceiling diffuser into the light
fixture
Model LT Shown
Finish: 25 - WT - White Tees with Black Borders
& Plenum Interior
PSD
Air
Diffuser
Height
8 (Typ.)
Volume
Control
Damper
Optional
Troffer
Slot
Regress
Air
Diffuser
Height
8 (Typ.)
3
8
Optional Side
Inlet Location
Hold Down Tabs
Typical Air Diffuser Length (L*)
Crossover Length (C)
Return
Height
8 (Typ.)
Air Pattern
Deflector
3
4
1
28
1
28
Side Outlet
Optional Side
Inlet Location
Side Outlet
Return
Height
8 (Typ.)
Optional Top
Inlet Location
Optional
Troffer
Slot
Optional
Regress
Troffer
Slot
Regress
1
28
3 (Typ.)
4
Typical
Air Diffuser
1
28
Width (W*)
5
Crossover Mounting Bracket
(Shipped Flat-Bent in
2 1/2
Volume Control
field to suit Light Troffer)
Damper
Optional
1
2
14
Air Pattern
* Typical air diffuser widths and lengths vary with air
Troffer
Deflector5
Slot
handling light troffer manufacturer. Specify the light
Regress
fixture manufacturer's name and model number on
1
14
all orders. Ceiling clearance required is typically 8"
3 (Typ.)
but can be as little as 6" above the ceiling line.
4
Optional
Top inlet units extend above this dimension.
Typical Air Diffuser
Volume
Troffer
* Typical Entire
Returndiffuser
lengthsisvary
with air
handlingassembled
light troffer
shipped
completely
Width (W*)
Control
Slot
manufacturer.
to the Specify
job site. the light fixture manufacturer's name
Damper
Regress
and model number on all orders. Ceiling clearance required
is typically 8" but can be as little as 6" above the ceiling line.
3
4
Mounting Bracket
(Shipped Flat-Bent in
2 1/2
field to suit Light Troffer)
2
Optional
Troffer
Slot
Regress
Hold Down Tabs
Mounting Bracket
(Shipped Flat-Bent in
field to suit Light Troffer)
3
8
PSD-230
3
8
1
28
Volume
Control
Damper
Air
Diffuser
Height
8 (Typ.)
Mounting Bracket
(Shipped Flat-Bent in
field to suit Light Troffer)
1
14
Volume
Control
Damper
3
4
3
8
Air
Diffuser
Height
8 (Typ.)
Optional Side
Inlet Location
Crossover
Volume Control
Damper
Optional
Troffer
Slot
Regress
Air Pattern
Deflector
Side Outlet
Optional
Troffer
Slot
Regress
Hold Down Tabs
1
14
Mounting Bracket
(Shipped Flat-Bent in
field to suit Light Troffer)
2 1/2
2
Return
Height
8 (Typ.)
3 (Typ.)
4
Typical Air Diffuser
Width (W*)
1
14
Volume
Control
Damper
3
4
2. Construction Details
Electrogalvanized steel plenum
Plenum inlets available in 4", 5" 6" and 7" (round or oval)
Other sizes may be available
PSD
Standard Finish:
24 Black Edges
Optional Top
Inlet Location
1
28
1
28
1. Available Finishes
3
4
3/2006
Slot
Regress
PSD-231
3/2006
Horizontal
5" Inlet
Vertical
2'
length
Horizontal
6" Inlet
Vertical
Horizontal
PSD
5" Inlet
Vertical
3'
length
Horizontal
6" Inlet
Vertical
Horizontal
5" Inlet
Vertical
4'
length
Horizontal
6" Inlet
Vertical
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
CFM
Ps
Pt
Throw
NC
10
20
0.020
0.022
3
20
0.020
0.022
2
20
0.019
0.020
3
20
0.019
0.020
2
30
0.024
0.027
2
30
0.021
0.024
2
30
0.024
0.025
2
30
0.021
0.023
2
40
0.028
0.033
2
40
0.026
0.032
2
40
0.028
0.030
2
40
0.026
0.029
2
15
30
0.045
0.048
5
<15
30
0.045
0.048
3
<15
30
0.043
0.045
5
<15
30
0.043
0.045
3
<15
45
0.053
0.060
5
<15
45
0.048
0.055
3
<15
45
0.053
0.057
5
<15
45
0.048
0.051
3
<15
60
0.062
0.075
4
<15
60
0.059
0.071
3
<15
60
0.062
0.068
4
<15
60
0.059
0.065
3
<15
10
10
20
40
0.081
0.086
6
15
40
0.081
0.086
4
15
40
0.077
0.080
6
15
40
0.077
0.080
4
15
60
0.095
0.107
7
18
60
0.085
0.097
4
18
60
0.095
0.100
7
18
60
0.085
0.091
4
18
80
0.111
0.132
6
23
80
0.105
0.126
4
23
80
0.111
0.121
6
23
80
0.105
0.115
4
23
11
11
12
12
10
10
25
50
0.126
0.134
8
22
50
0.126
0.134
4
22
50
0.121
0.125
8
22
50
0.121
0.125
4
22
75
0.148
0.167
8
25
75
0.133
0.152
5
25
75
0.148
0.157
8
25
75
0.133
0.142
5
25
100
0.173
0.207
7
30
100
0.164
0.197
5
30
100
0.173
0.190
7
30
100
0.164
0.180
5
30
12
12
13
13
12
12
CFM/LF
30
60
0.182
0.194
6 9 13
28
60
0.182
0.194
4 5
9
28
60
0.174
0.180
6 9 13
28
60
0.174
0.180
4 5
9
28
90
0.213
0.240
7 10 15
31
90
0.192
0.219
4 6 10
31
90
0.213
0.226
7 10 15
31
90
0.192
0.205
4 6 10
31
120
0.250
0.298
6 9 13
37
120
0.236
0.284
4 6
9
37
120
0.250
0.273
6 9 13
37
120
0.236
0.259
4 6
9
37
35
70
0.247
0.264
10
33
70
0.247
0.264
6
33
70
0.237
0.245
10
33
70
0.237
0.245
6
33
105
0.290
0.327
11
37
105
0.261
0.298
7
37
105
0.290
0.308
11
37
105
0.261
0.279
7
37
140
0.340
0.406
10
44
140
0.321
0.387
7
44
140
0.340
0.372
10
44
140
0.321
0.352
7
44
PSD-232
14
14
16
11
16
11
14
10
14
10
40
80
0.323
0.344
11
37
80
0.323
0.344
7
37
80
0.309
0.320
11
37
80
0.309
0.320
7
37
120
0.379
0.427
12
42
120
0.341
0.390
8
42
120
0.379
0.402
12
42
120
0.341
0.365
8
42
15
10
10
15
10
10
17
12
17
12
50
100
0.504
0.538
12
44
100
0.504
0.538
8
44
100
0.483
0.499
12
44
100
0.483
0.499
8
44
17
11
17
11
3/2006
6" Inlet
5" Inlet
3x3
(W x L)
6" Inlet
5" Inlet
1x4
2x4
4x4
(W x L)
6" Inlet
25
50
0.040
0.048
2
<15
50
0.040
0.048
3
<15
50
0.037
0.042
2
<15
50
0.037
0.042
3
<15
75
0.048
0.067
2
<15
75
0.048
0.067
2
<15
75
0.042
0.051
2
<15
75
0.042
0.051
2
<15
100
0.065
0.099
3
16
100
0.065
0.099
2
16
100
0.058
0.074
3
16
100
0.058
0.074
2
16
30
60
0.057
0.070
2
<15
60
0.057
0.070
3
<15
60
0.054
0.060
2
<15
60
0.054
0.060
3
<15
90
0.069
0.096
4
16
90
0.069
0.096
3
16
90
0.061
0.074
4
16
90
0.061
0.074
3
16
120
0.094
0.142
4
21
120
0.094
0.142
4
21
120
0.083
0.107
4
21
120
0.083
0.107
4
21
35
70
0.078
0.095
3
17
70
0.078
0.095
4
17
70
0.073
0.081
3
17
70
0.073
0.081
4
17
105
0.093
0.130
4
21
105
0.093
0.130
4
21
105
0.083
0.101
4
21
105
0.083
0.101
4
21
140
0.127
0.193
5
26
140
0.127
0.193
4
26
140
0.113
0.145
5
26
140
0.113
0.145
4
26
CFM/LF
40
80
0.102
0.124
5 2 3
21
80
0.102
0.124
8 3 4
21
80
0.096
0.106
5 2 3
21
80
0.096
0.106
8 3 4
21
120
0.122
0.170
8 3 5
25
120
0.122
0.170
7 3 4
25
120
0.108
0.132
8 3 5
25
120
0.108
0.132
7 3 4
25
160
0.166
0.252
8 4 5
30
160
0.166
0.252
7 3 5
30
160
0.148
0.189
8 4 5
30
160
0.148
0.189
7 3 5
30
10
10
45
90
0.129
0.156
3
25
90
0.129
0.156
5
25
90
0.121
0.135
3
25
90
0.121
0.135
5
25
135
0.154
0.215
5
29
135
0.154
0.215
5
29
135
0.137
0.167
5
29
135
0.137
0.167
5
29
180
0.210
0.319
6
33
180
0.210
0.319
5
33
180
0.187
0.240
6
33
180
0.187
0.240
5
33
10
10
50
100
0.160
0.193
4
28
100
0.160
0.193
5
28
100
0.150
0.166
4
28
100
0.150
0.166
5
28
150
0.191
0.266
6
32
150
0.191
0.266
5
32
150
0.169
0.206
6
32
150
0.169
0.206
5
32
200
0.260
0.394
7
37
200
0.260
0.394
6
37
200
0.231
0.296
7
37
200
0.231
0.296
6
37
11
11
10
10
55
110
0.193
0.234
4
32
110
0.193
0.234
6
32
110
0.181
0.201
4
32
110
0.181
0.201
6
32
165
0.231
0.322
7
35
165
0.231
0.322
6
35
165
0.205
0.249
7
35
165
0.205
0.249
6
35
220
0.314
0.477
7
41
220
0.314
0.477
6
41
220
0.280
0.358
7
41
220
0.280
0.358
6
41
10
10
11
11
10
10
60
120
0.230
0.278
4
36
120
0.230
0.278
7
36
120
0.216
0.239
4
36
120
0.216
0.239
7
36
180
0.274
0.383
7
37
180
0.274
0.383
7
37
180
0.244
0.296
7
37
180
0.244
0.296
7
37
10
10
2x2
(W x L)
20
40
0.026
0.031
1
<15
40
0.026
0.031
2
<15
40
0.024
0.027
1
<15
40
0.024
0.027
2
<15
60
0.030
0.043
2
<15
60
0.030
0.043
2
<15
60
0.027
0.033
2
<15
60
0.027
0.033
2
<15
80
0.042
0.063
3
<15
80
0.042
0.063
2
<15
80
0.037
0.047
3
<15
80
0.037
0.047
2
<15
12
PSD
5" Inlet
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
15
30
0.014
0.017
1
<15
30
0.014
0.017
1
<15
30
0.013
0.015
1
<15
30
0.013
0.015
1
<15
45
0.017
0.024
1
<15
45
0.017
0.024
1
<15
45
0.015
0.019
1
<15
45
0.015
0.019
1
<15
60
0.023
0.035
2
<15
60
0.023
0.035
1
<15
60
0.021
0.027
2
<15
60
0.021
0.027
1
<15
12
PSD-233
3/2006
5" Inlet
2x2
(W x L)
6" Inlet
PSD
5" Inlet
3x3
(W x L)
6" Inlet
5" Inlet
1x4
2x4
4x4
(W x L)
6" Inlet
PSD-234
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
CFM
Ps
Horiz. Pt
Throw
NC
CFM
Ps
Vert. Pt
Throw
NC
15
30
0.016
0.019
1
30
0.016
0.019
1
30
0.014
0.016
1
30
0.014
0.016
1
45
0.021
0.028
1
45
0.021
0.028
1
45
0.018
0.022
1
45
0.018
0.022
1
60
0.031
0.043
2
60
0.031
0.043
1
60
0.026
0.032
2
60
0.026
0.032
1
20
40
0.029
0.035
1
40
0.029
0.035
2
40
0.025
0.028
1
40
0.025
0.028
2
60
0.038
0.050
2
60
0.038
0.050
2
60
0.033
0.039
2
60
0.033
0.039
2
80
0.056
0.077
2
<15
80
0.056
0.077
1
<15
80
0.046
0.056
2
<15
80
0.046
0.056
1
<15
25
50
0.046
0.054
2
50
0.046
0.054
3
50
0.040
0.044
2
50
0.040
0.044
3
75
0.059
0.078
2
<15
75
0.059
0.078
2
<15
75
0.051
0.060
2
<15
75
0.051
0.060
2
<15
100
0.087
0.121
3
20
100
0.087
0.121
1
20
100
0.072
0.088
3
20
100
0.072
0.088
1
20
30
60
0.066
0.078
2
<15
60
0.066
0.078
3
<15
60
0.057
0.063
2
<15
60
0.057
0.063
3
<15
90
0.085
0.112
4
19
90
0.085
0.112
4
19
90
0.074
0.087
4
19
90
0.074
0.087
4
19
120
0.125
0.174
3
25
120
0.125
0.174
2
25
120
0.103
0.127
3
25
120
0.103
0.127
2
25
35
70
0.089
0.106
3
17
70
0.089
0.106
4
17
70
0.078
0.086
3
17
70
0.078
0.086
4
17
105
0.115
0.152
4
24
105
0.115
0.152
4
24
105
0.100
0.118
4
24
105
0.100
0.118
4
24
140
0.171
0.237
4
29
140
0.171
0.237
3
29
140
0.141
0.172
4
29
140
0.141
0.172
3
29
CFM/LF
40
80
0.117
0.138
10 2 4
22
80
0.117
0.138
7 3 4
22
80
0.102
0.112
10 2 4
22
80
0.102
0.112
7 3 4
22
120
0.150
0.199
8 3 5
28
120
0.150
0.199
8 3 5
28
120
0.131
0.154
8 3 5
28
120
0.131
0.154
8 3 5
28
160
0.223
0.309
7 3 4
33
160
0.223
0.309
7 2 4
33
160
0.184
0.225
7 3 4
33
160
0.184
0.225
7 2 4
33
11
11
10
10
45
90
0.148
0.175
5
26
90
0.148
0.175
5
26
90
0.129
0.142
5
26
90
0.129
0.142
5
26
135
0.190
0.252
5
31
135
0.190
0.252
5
31
135
0.166
0.195
5
31
135
0.166
0.195
5
31
180
0.282
0.391
5
37
180
0.282
0.391
5
37
180
0.233
0.285
5
37
180
0.233
0.285
5
37
11
11
11
11
11
11
50
100
0.182
0.216
6
29
100
0.182
0.216
5
29
100
0.159
0.175
6
29
100
0.159
0.175
5
29
150
0.235
0.311
6
34
150
0.235
0.311
6
34
150
0.205
0.241
6
34
150
0.205
0.241
6
34
200
0.349
0.483
5
41
200
0.349
0.483
6
41
200
0.287
0.352
5
41
200
0.287
0.352
6
41
12
12
11
12
11
12
10
10
55
110
0.221
0.261
7
32
110
0.221
0.261
6
32
110
0.193
0.212
7
32
110
0.193
0.212
6
32
165
0.284
0.376
6
36
165
0.284
0.376
7
36
165
0.248
0.292
6
36
165
0.248
0.292
7
36
13
13
12
12
12
12
60
120
0.263
0.311
9
36
120
0.263
0.311
6
36
120
0.229
0.253
9
36
120
0.229
0.253
6
36
180
0.339
0.447
7
39
180
0.339
0.447
7
39
180
0.295
0.347
7
39
180
0.295
0.347
7
39
13
10
13
10
12
13
12
13
3/2006
Series LT - Specifications
Single Sided Supply - Light Troffer Diffuser - T-bar Lay-in - Insulated/Non Insulated/Model SS-LT(I)-6
Single sided supply light troffer diffusers shall be METALAIRE SS-LT-6 (noninsulated) or SSI-LT-6 (insulated). Light troffer diffusers shall be of the sizes
as shown on the device schedule and shall be fabricated to fit the manufacturer and model of light fixture specified.
Diffuser shall be single sided with a side entrance inlet. Units shall be shipped fully assembled and include hold down tabs for positive alignment and
locking the light troffer diffuser onto the slot of the light fixture.
Inlets shall be oval, centrally located, with a minimum depth of 2 1/8" for ease of duct connection. Light troffer diffusers shall be constructed of corrosion
resistant galvanized steel.
Performance data is supplied for selection purposes, and is based on a regressed slot with the pattern controller supplied in the diffuser. It should be noted
that actual job performance will vary depending on the type of light fixture used, the configuration of the pattern controller if supplied by the light fixture
manufacturer, and variances in the physical dimensions from one light fixture manufacturer to another.
Insulated diffusers shall be model SSI-LT-6. Internal Insulation shall be 1/2" thick matte face. External insulation shall be 1/2" thick with a vapor barrier.
Matening return should be model SSRI-LT-6, insulated or model SSR-LT-6, non insulated.
Double Sided Supply - Side/Top Inlet - Light Troffer Diffuser - T-bar Lay-in - Insulated/Non Insulated/Model DS-LT(I)-6
PSD
Double sided supply light troffer diffusers shall be METALAIRE DS-LT-6 or DST-LT-6 (noninsulated) or DSI-LT-6 or DSTI-LT-6 (insulated). Light troffer
diffusers shall be of the sizes as shown on the device schedule and shall be fabricated to fit the manufacturer and model of light fixture specified.
Diffusers shall be double sided and be available with either a top or side entrance inlet. Units shall be shipped fully assembled and include hold down tabs
for positive alignment and locking the light troffer diffuser onto the slot of the light fixture.
Side inlets shall be oval; top inlets shall be round.
Inlets shall be centrally located, with a minimum depth of 2 1/8" for ease of duct connection. Light troffer diffusers shall be constructed of corrosion
resistant galvanized steel.
Diffuser face shall be black.
Insulated diffusers shall be model DSI-LT-6 or DSTI-LT-6. Internal insulation shall be 1/2" thick matte face. External insulation shall be 1/2" thick with a
vapor barrier.
PSD-235
3/2006
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
Pencil Hardness
ASTM D3363-92A
70-80%
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
PSD
Property
PSD-236
3/2006
Length
Single Sided
Supply
Inlet
Available Finishes
4"
Standard
5"
24"
36"
48"
27 - All Black
6"
7"
SSRI-LT-6 - Insulated
Double Sided
Side Inlet
DS-LT-6 - Non Insulated
DSI-LT-6 - Insulated
Top Inlet
DST-LT-6 - Non Insulated
12" x 48"
24" x 24"
24" x 48"
PSD
DSTI-LT-6 - Insulated
PSD-237
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suites your air distribution design needs.
Our Pre-Flite catalog is a condensed reference guide containing the listing of our
complete product offers for grilles, registers, diffusers, and air terminal units. This
catalog can be used to help select the type of device, along with available border
styles. The catalog includes photos of each model along with the features and
model guide, a great tool when you are trying to select a device for your project.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalog and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog is the leading product catalog in the industry. Included
in this catalog are the complete product listings, drawings, product features and benefits,
product performance data, specifications, and model specifications. This catalog is
organized to make it quick and easy to find the information you are looking for.
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
A
A
R
R
P
P
ARCHITECTURAL
ARCHITECTURAL
DIFFUSERS
DIFFUSERS
3/2006
Model 5500DD
Pg. 242
Series 5500DD offers an architectural air diffuser designed to excel in both performance and aesthetic appeal
The unique horizontal lip on all sides of the diffuser face provides a horizontal air pattern that is
tight to the ceiling. This attribute makes the series 5500DD ideally suited for maximum occupant comfort,
even in variable volume systems
The series 5500DD is shipped fully assembled and is designed to allow the ceiling tile to be installed
(by others) from the face without having to remove the plenum. This means the center tile can be installed
after the diffuser has been installed in the ceiling
The series 5500DD, available in both supply and return models, is offered in a wide variety of border styles
and slot configurations, allowing for maximum design flexibility
Supply unit constructed with extruded aluminum face and steel backpan. Return units include steel light
shield/baffle
Available with 1 to 4 slots
The series 5500DD is an excellent choice for VAV applications
Louvered Face
Supply
Insulated
Non-Insulated
Return
ARP
Model 6600SQ
Pg. 248
The series 6600SQ provides outstanding operation flexibility. The supply units are shipped with pattern
controllers that are individually adjustable from the face of the diffuser. This feature allows the direction of air
flow to be adjusted a full 180. The return is shipped without pattern controller to minimize sound and
pressure drop
The series 6600SQ is shipped fully assembled and is designed to allow the ceiling tile to be installed
(by others) from the face without having to remove the plenum. This means the center tile can be installed
after the diffuser has been installed in the ceiling
The series 6600SQ, available in both supply and return models, is offered in a wide variety of border styles
and slot configurations, allowing for maximum design flexibility
Supply unit constructed with extruded aluminum face and pattern controllers, with a steel backpan. Return
units include steel light shield/baffle
Available with 1 to 4 slots
The series 6600SQ is an excellent choice for VAV applications
Modular Slot
Supply
Insulated
Non-Insulated
ARP-240
Return
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
ARP
Optional Internal
Insulation
ModelDuct
5500DD-6
Shown
Size - 1
4
2
8 41
Duct Size - 41
Return Air
Opening
Light Shield
8"
8 41
Ceiling Tee By Others
ARP-242
Light Shield
Ceiling Tee
By Others
For moreReturn
productAir
information visit us at www.metalaire.com
Opening
Ceiling Tile
By Others
Ceiling Tile
By Others
Ceiling Tee
By Others
3/2006
Face View
1. Available Finishes
2. Available Accessories
Standard Finish:
01 White w/black plenum
Optional Finish (additional charge):
28 Custom color
Optional Internal
Insulation
3. Construction Details
Insulated units have 1/2" Tuffskin insulation
Center ceiling tile supplied by others, field
installed.
Return units are non-ducted, with light
shields
2
8 41
Ceiling Tile By Others
ARP
Return Air
Opening
Light Shield
8"
Ceiling Tee
By Others
Ceiling Tile
By Others
ARP-243
slot
slot
ARP
slot
slot
slot
Total Pressure
50
0.01
100
0.03
150
0.07
200
0.13
250
0.20
300
0.30
350
0.40
Static Pressure
0.007
0.024
0.058
0.109
0.168
Throw
2-3-5
4-5-7
5-6-9
6-8-10
Total Pressure
0.02
0.05
0.08
0.12
NC
CFM
<20
100
<20
150
22
200
28
250
33
300
0.18
0.254
38
350
0.24
0.337
41
400
0.31
Static Pressure
0.014
0.038
0.059
0.088
0.134
0.177
Throw
2-3-5
3-5-7
4-6-8
4-7-9
5-8-11
6-9-12 7-10-13
Total Pressure
0.03
0.06
0.09
0.13
0.18
NC
CFM
<20
150
<20
200
22
250
28
300
33
350
38
400
0.23
0.227
41
450
0.30
Static Pressure
0.018
0.039
0.058
0.084
0.117
0.147
Throw
3-4-6
4-5-7
4-6-8
5-7-9
5-8-10
6-9-12 7-10-14
Total Pressure
0.05
0.08
0.11
0.16
0.20
NC
CFM
<20
200
<20
250
25
300
30
350
34
400
38
450
0.26
0.194
41
500
0.32
Static Pressure
0.029
0.048
0.064
0.097
0.117
0.154
Throw
3-4-9
3-5-7
4-6-8
5-7-10
5-8-11
6-9-12 6-10-13
Total Pressure
0.061
0.085
0.123
0.151
0.196
0.247
0.298
NC
20
25
29
33
36
39
41
NC
CFM
Static Pressure
ARP-244
Throw
<20
250
0.48
3-5-7
23
300
0.085
4-6-8
28
350
0.123
5-7-10
32
400
0.151
5-8-11
36
450
0.196
39
500
0.247
0.195
42
550
0.298
3/2006
3/2006
1
2
3
4
Models 5500DDR-6/Return
slot
165
200
225
275
Negative
0.02"
0.03"
0.06"
0.08"
0.10"
0.15"
NC
<20
22
24
27
32
190
25
250
30
310
003"
0.06"
0.08"
0.10"
NC
21
24
25
29
34
225
275
360
450
0.02"
003"
0.06"
0.08"
0.10"
NC
22
25
27
30
35
6"
0.196
300
0.02"
8"
0.349
0.006
350
400
003"
9"
0.441
0.010
430
500
10"
0.545
0.016
590
0.06"
600
0.023
700
0.031
37
0.15"
620
38
0.15"
660
0.08"
12"
0.785
425
505
Negative
295
35
345
0.02"
Negative
Velocity Pressure
22
Negative
CFM
slot
20
155
CFM
slot
Inlet Size
125
<20
CFM
slot
Total Ft. 2
100
NC
810
40
0.10"
14"
1.07
CFM
0.15"
16"
1.40
800
0.040
900
0.051
1000
0.063
1100
0.075
1200
0.090
1400
0.122
1600
0.160
To determine total pressure for other inlet sizes, divide the CFM by the square footage of the inlet size (chart below). The result is the duct velocity in feet per
minute. From thevelocity pressure chart, determine the velocity pressure and add it to the static pressure shown in the performance chart to determine the
total pressure.
ARP
Horizontal throw - values are at terminal velocities of 150, 100 and 50 fpm respectively, using 4-way pattern.
NC - based on Lw Re 10-12 watts and minus a 10dB room absorption. Where no value is shown, NC is less than 20.
Static pressure - is for diffuser only.
Total pressure - includes plenum and inlet collar size listed and is the sum of velocity and static pressure.
Example: determine TP for a four slot 6700SQ-50CD with a 9" inlet at 350 CFM. 350, 0.441 = 794 fpm duct velocity. 800 fpm duct velocity = 0.04 Vp +
0.045Sp = 0.085T.P. All values based on isothermal air. All pressures are in inches, W.G.
ARP-245
3/2006
Non-Insulated
5500DD-6 - T-bar Lay-in
5500DD-9 - Donn Fineline
Air Outlets shall be model 5500DDI (insulated) or 5500DD (non-insulated) manufactured by METALAIRE. Units shall be square face ceiling supply
diffusers and shall have a factory attached back. Back pan must be of sufficient height to allow center tile (by the ceiling system manufacturer) to be
installed from the diffuser face without dissembling the face from the back pan. Devices without back pan attached to the diffuser face will not be allowed.
The units shall be the size and quantity as outline in the plans and specifications.
Diffuser shall be one through four slots. The diffuser shall be designed to integrate with the ceiling type. It shall have horizontal deflection surfaces on the
fixed pattern control blades which provide a horizontal ceiling pattern with a twenty degree cooling temperature differential at twenty percent of design
volume.
ARP
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
ARP-246
Test Method
Performance
Film thickness
.8-1.0 mils
Film Cure
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Inlet
Number of Slots
6"
8"
10"
12"
Module
Available Finishes
Standard
Available Options
D3
SD3
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
TBPF
28 - Custom Color
Number of Slots
Module
1
2
Standard
01 -White Face w/Black Back Pan
24" x 24"
3
4
Options
28 - Custom Color
ARP
Available Finishes
24" x 24"
ARP-247
3/2006
ARP
Product Details
The series 6600SQ provides outstanding
operation flexibility. The supply units are shipped
with pattern controllers that are individually
adjustable from the face of the diffuser. This
feature allows the direction of air flow to be
adjusted a full 180. The return is shipped
without pattern controller to minimize sound and
Ceiling Tile by Others
pressure drop
23 3
4
OPTIONAL
Internal
Insulation
1"
Duct Size - 4
Ceiling Tee
By Others
Ceiling Tile
By Others
1"
Duct Size - 4
Light Shield
8"
Ceiling Tee
By Others
ARP-248
Light Shield
Ceiling Tee
By Others
Ceiling Tile
By Others
Ceiling Tile
By Others
3/2006
Face View
23 3
4
3 Slot
S
1/2"
A
4"
S
1/2"
4 Slot
6650SQ-6
6675SQ-6
3/4"
3"
3/4"
4 1/2"
3/4"
6"
3/4"
7 1/2"
6610SQ-6
1"
3 1/4"
1"
5"
1"
6 3/4"
1"
8 1/2"
1. Available Finishes
A
2 3/4"
OPTIONAL
Internal
Insulation
Standard Finish:
20 White w/black pattern controllers
Ceiling Tee
Optional Finish (additional charge):
By Others
28 Custom color
Light Shield
A
5 1/4"
S
1/2"
A
6 1/2"
1"
Duct Size - 4
2. Available Accessories
Ceiling Tile
By Others
3. Construction Details
Insulated units have 1/2" Tuffskin insulation
Center ceiling tile supplied by others, field
installed.
Return units are non-ducted, with light
shields
Three slot widths available: 6650 (1/2"),
6675 (3/4"), and 6610 (1")
Ceiling Tee
By Others
2 Slot
S
1/2"
Ceiling Tile
By Others
ARP
1 Slot
Model
ARP-249
3/2006
27
0.302
0.370
0.42
41
48
150
0.305
200
250
0.42
52
275
5-8-12
7-10-15
9-3-19
11-18-22
0.03
0.051
0.11
0.18
0.28
0.35
0.059
0.122
100
2-4-5
200
225
250
45
300
7-10-15
9-12-18
0.076
0.125
0.16
0.19
0.265
0.146
0.187
21
200
0.222
27
250
35
275
300
0.312
43
350
5-7-8
7-10-12
8-11-14
9-13-17
11-15-21
0.094
0.14
0.175
0.19
0.255
Total Pressure
0.061
0.103
NC
22
0.056
38
6-9-13
NC
3-5-6
29
0.39
5-8-11
0.088
150
0.312
3-6-7
0.042
0.036
0.021
24
150
Total Pressure
Static Pressure
225
0.251
35
125
200
4-7-10
NC
Horizontal
0.227
175
3-5-7
0.034
CFM
0.19
Total Pressure
Static Pressure
slot
0.086
0.102
75
Horizontal
0.023
CFM
slot
8-13-19
NC
Static Pressure
150
6-10-15
0.028
Horizontal
slot
100
4-6-8
Total Pressure
CFM
50
Static Pressure
CFM
Horizontal
0.153
0.191
28
0.209
32
37
0.282
40
ARP
slot
3
4
Inlet Size
Total Ft. 2
0.272
0.074
0.105
0.145
0.124
24
250
26
300
350
0.172
31
400
5-7-15
6-9-17
7-11-19
8-13-22
0.018
0.031
0.048
0.059
0.090
0.115
350
400
0.040
0.051
0.078
22
250
0.117
25
300
28
0.149
32
450
3-4-8
4-5-11
6-9-15
7-10-18
8-11-20
8-13-22
0.021
0.031
0.044
0.062
0.075
0.094
400
0.087
20
200
200
9"
0.441
0.010
0.068
4-5-12
NC
300
0.033
3-4-9
0.025
0.006
39
350
0.049
Total Pressure
300
0.026
8"
250
0.013
NC
0.349
200
32
8-14-20
0.023
6"
28
7-12-18
Total Pressure
0.196
150
150
Static Pressure
20
0.319
6-10-16
Horizontal
Velocity Pressure
0.187
0.219
5-8-13
NC
CFM
0.125
0.145
3-6-10
0.015
Static Pressure
slot
0.071
0.083
2-4-7
Total Pressure
Horizontal
0.033
CFM
slot
10-15-20
Static Pressure
300
8-12-18
NC
Horizontal
250
6-10-16
0.039
100
200
4-8-13
0.013
0.011
150
35-9
Total Pressure
CFM
slot
100
2-3-5
Static Pressure
50
Horizontal
500
0.038
0.064
10"
0.545
0.016
600
0.075
12"
0.785
0.023
700
0.031
0.092
22
14"
25
0.117
28
16"
1.07
1.40
800
0.040
900
0.051
1000
0.063
1100
0.075
1200
0.090
1400
0.122
1600
0.160
ARP-250
3/2006
3
4
0.034
0.059
0.090
0.125
0.165
0.080
150
0.122
27
200
0.172
30
250
38
330
350
0.228
44
400
Horizontal
2-4-10
3-6-12
5-8-15
7-10-17
8-13-21
8-15-24
Static Pressure
0.025
0.041
0.061
0.084
0.110
0.135
0.030
0.050
0.074
200
0.103
22
250
0.137
28
300
35
350
400
0.169
39
450
Horizontal
4-5-10
5-7-13
6-8-16
7-9-19
8-11-21
9-13-23
Static Pressure
0.023
0.035
0.046
0.061
0.074
0.094
450
500
0.028
NC
0.042
CFM
0.055
250
0.074
20
300
0.090
25
350
29
400
0.117
34
Horizontal
4-5-10
5-7-13
6-8-15
7-10-19
7-11-20
8-12-22
Static Pressure
0.027
0.038
0.045
0.55
0.68
0.081
Total Pressure
0.034
NC
6"
0.196
0.046
Total Pressure
0.017
0.023
CFM
slot
Total Ft. 2
Static Pressure
NC
350
11-16-22
Total Pressure
slot
300
9-14-20
CFM
250
8-12-18
NC
slot
200
6-9-15
Total Pressure
150
5-7-13
300
8"
0.349
0.006
400
0.048
9"
0.441
0.010
500
0.059
20
10"
0.545
0.016
600
0.071
23
12"
0.785
0.023
700
0.031
0.091
27
14"
30
slot
100
3-5-10
0.107
33
16"
1.07
1.40
800
0.040
900
0.051
1000
0.063
1100
0.075
1200
0.090
1400
0.122
1600
0.160
ARP
CFM
Horizontal
ARP-251
3/2006
Non-insulated
6600SQ-6 - T-bar Lay-in
6600SQ-9 - Donn Fineline
Air Outlets shall be model 6600SQI (insulated) or 6600SQ (non-insulated) manufactured by METALAIRE. Units shall be square face ceiling supply diffusers
and shall have a factory attached back. Back pan must be of sufficient height to allow center tile (by the ceiling system manufacturer) to be installed from
the diffuser face without dissembling the face from the back pan. Devices without back pan attached to the diffuser face will not be allowed. The units shall
be the size and quantity as outline in the plans and specifications.
Outlet pattern controllers shall be curved, aerodynamically shaped, capable of adjustment from the face of the diffuser. The pattern controllers shall allow
adjustment from vertical to horizontal patterns as well as damper the volume through the face of the diffuser. In the horizontal position, pattern controllers
shall be field adjustable to obtain a 1 way, 2 way opposite, 2 way corner, 3 way, and 4 way directional air patterns. Pattern controllers shall be aluminum
construction. Steel pattern controllers are not acceptable.
Diffuser shall be one through four slots. Units shall be available with 1/2", 3/4" or 1" slot widths.The diffuser shall be designed to integrate with the ceiling
type.
Return Square and Rectangular Louvered Face - Aluminum/Series 6600SQR
Non-insulated
6600SQR-6 - T-bar Lay-in
6600SQR-9 - Donn Fineline
Air Inlets shall be model 6600SQR manufactured by METALAIRE. Units shall be square face ceiling return or exhaust diffusers and shall have a factory
attached light shield. Light shield must be of sufficient height to allow center tile (by the ceiling system manufacturer) to be installed from the diffuser face
without dissembling the face from the back pan. Devices without light shield attached to the diffuser face will not be allowed. The units shall be the size
and quantity as outline in the plans and specifications.
ARP
Diffuser shall be one through four slots. Units shall be available with 1/2", 3/4" or 1" slot widths. The diffuser shall be designed to integrate with the ceiling
type. Face shall be designed to match the appearance of the supply unit.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Paint Specification
Process shall be anodic electrodeposition using an anodic acrylic paint. Units shall undergo pre-treatment including a pressurized spray stage using an
alkaine cleaner and a de-ionized water rinse.
Film Properties shall meet or exceed the following standards:
Property
Test Method
Film thickness
.8-1.0 mils
Film Cure
ARP-252
Performance
320 F @ 20 min
Gloss 60 deg.
ASTM D523-89
70-80%
Pencil Hardness
ASTM D3363-92A
HB-H
Crosshatch Adhesion
ASTM D3359-95
4B-5B
Direct Impact
ASTM D2794-93
Reverse Impact
ASTM D2794-93
60 in.lbs. Min.
Salt Spray
ASTM B117-95
48-96 Hours
Humidity
ASTM D1735-92
500 Hours
Water Soak
ASTM D870-92
250 Hours
3/2006
Slot Width
Inlet
Number of Slots
Module
Available Finishes
1/2"
6"
3/4"
8"
1"
10"
Pattern Controllers
12"
Available Options
Standard
Damper - aluminum
Radial Opposed Blade
SD3
Damper - steel
Optional
24" x 24"
Insulated
28 - Custom Color
G3
Equalizing Grid
BDS
Butterfly Damper
RSD
TBPF
Slot Width
Inlet
Number of Slots
1/2"
6"
3/4"
8"
1"
10"
12"
Available Finishes
Standard
01 - White Face
24" x 24"
Optional
28 - Custom Color
ARP
Module
ARP-253
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
E
E
H
H
D
D
ENVIRONMENTAL/
ENVIRONMENTAL/
HOSPITAL DIFFUSERS
HOSPITAL DIFFUSERS
3/2006
Model HPL-CL
Pg. 260
The HPL laminar flow diffusers are engineered for supply air distribution in critical environments such as
hospital operating rooms and clean rooms. The diffusers are engineered to supply a low velocity vertical
piston of conditioned air
The HPL-CL laminar is easy to clean and sterilize. The face and core assembly can be removed from the face
for cleaning. With the face and core assembly removed, the interior of the backpan and inlet collar are free of
obstructions and easy to access
The diffuser is available with a choice of three free areas for the perforated face: 23%, 40% and 51%
maximizing the range of capacities for the HPL. The HPL is also available in aluminum or
stainless steel construction
Laminar Flow
Aluminum
Stainless Steel
SS Face/Aluminum Backpan
HPL-CL-AL-1
HPL-CL-SS-1
HPL-CL-SA-1
T-bar Lay-in
HPL-CL-AL-6
HPL-CL-SS-6
HPL-CL-SA-6
Model HPL-HA
Pg. 266
When the application calls for the HEPA filters to be located in the supply diffuser, the HPL-HA is an excellent
choice. The series HPL-HA laminar flow diffusers are engineered for supply air distribution in critical
environments such as hospital operating rooms and clean rooms. The diffusers are engineered to supply a
low velocity vertical piston of conditioned air
The series HPL-HA design includes a HEPA filter cell accessible from the face of the diffuser. The face and
core assembly can be removed from the face for cleaning. This feature allows the filters to be removed and
replaced from the diffuser face
The diffuser is available with a choice of three free areas for the perforated face: 23%, 40% and 51%
maximizing the range of capacities for the HPL. The HPL is also available in aluminum or stainless
steel construction
Optional HEPA filters are available
Laminar Flow
EHD
Environmental/Hospital Diffusers
Surface Mount
Surface Mount
Aluminum
Stainless Steel
SS Face/Aluminum Backpan
HPL-HA-AL-1
HPL-HA-SS-1
HPL-HA-SA-1
T-bar Lay-in
HPL-HA-AL-6
HPL-HA-SS-6
HPL-HA-SA-6
Model HPL-PR
Pg. 272
The series HPL-PR is specifically engineered to improve patient comfort in critical health care applications
such as isolation rooms and trauma centers. The unique design provides a tent of conditioned air around
the patient
The unique design of the patented HPL-PR provides filtered air to protect the patient and at the same time
minimize the air velocities that impact the patient. This device provides a high level of comfort
Series HPL-PR includes a HEPA filter section. Optional HEPA filters are available. HPL-PR configuration
minimizes induction, distributing low velocity air with minimum aspiration
Unit is aluminum construction and is available for Surface Mount and T-bar Lay-in applications, and is also
available for special 1 1/2 wide T-bar Lay-in applications
Laminar Flow - Patient Isolation Applications
Surface Mount
Aluminum
Stainless Steel
SS Face/Aluminum Backpan
EHD-256
HPL-PR-AL-1
HPL-PR-SS-1
HPL-PR-SA-1
T-bar Lay-in
HPL-PR-AL-6
HPL-PR-SS-6
HPL-PR-SA-6
3/2006
Model HRD-CL
Pg. 278
The HRD-CL radial discharge pattern diffusers are engineered for supply air distribution in critical
environments such as chemistry labs and clean rooms. The diffusers are engineered to supply a low velocity
of conditioned air in a radial pattern from the ceiling
The HRD-CL radial discharge pattern diffusers are easy to clean and sterilize. The face and core assembly
can be removed from the face for cleaning. With the face and core assembly removed, the interior of the
backpan and inlet collar are free of obstructions and easy to access
The diffuser is available in stainless steel or heavy aluminum construction. Units available in 90 or
180 throw
Radial Discharge
Aluminum
Stainless Steel
SS Face/Aluminum Backpan
HRD-CL-AL-1
HRD-CL-SS-1
HRD-CL-SA-1
T-bar Lay-in
HRD-CL-AL-6
HRD-CL-SS-6
HRD-CL-SA-6
Model HRD-HA
Pg. 284
The series HRD-HA radial discharge pattern diffusers includes a HEPA filter section and are engineered for
supply air distribution in critical environments such as chemistry labs and clean rooms. The diffusers are
engineered to supply a low velocity of conditioned air in a radial pattern from the ceiling
The series HRD-HA design includes a HEPA filter cell accessible from the face of the diffuser. The face and
core assembly can be removed from the face for cleaning. This feature allows the filters to be removed and
replaced from the diffuser face. Optional HEPA filters are available
The HRD-HA Radial Discharge Pattern Diffusers are easy to clean and sterilize. The face and core assembly
can be removed from the face for cleaning. With the face and core assembly removed, the interior of the
backpan and inlet collar are free of obstructions and easy to access
The diffuser is available in stainless steel or heavy aluminum construction.
Units available in 90 or 180 throw
Optional HEPA Filters are available
Radial Discharge - w/HEPA Filter Cell
Flush Mount
Aluminum
Stainless Steel
SS Face/Aluminum Backpan
HRD-HA-AL-1
HRD-HA-SS-1
HRD-HA-SA-1
T-bar Lay-in
HRD-HA-AL-6
HRD-HA-SS-6
HRD-HA-SA-6
EHD
Environmental/Hospital Diffusers
Flush Mount
HRD-HA-AL-6M
HRD-HA-SS-6M
HRD-HA-SA-6M
EHD-257
3/2006
Model
Periflow
Pg. 290
The Periflow operating room air distribution system provides control over particulate matter within the
operating room environment
The system has been tested in accordance with the guidelines set forth by the Committee on Operating
Room Environments of the American College of Surgeons as published in the January 1976 Bulletin and
meets Class 1 Microbiological Air Cleanliness guidelines. The system provides the highest standard of air
cleanliness for patients undergoing minor procedures or surgeries as critical as organ transplants
The system is in either stainless steel or heavy aluminum construction to ensure ling-term durability and
resistance to strong germicidal solutions. In addition, each system is custom designed and precisely
fabricated to accommodate the specialized medical, mechanical, and electrical considerations of todays
operating room environments
By its compact yet efficient design, the Periflow system allows the designer the flexibility to properly provide
for all the various components competing for space above the operating room ceiling
EHD
Environmental/Hospital Diffusers
Flush Mount
Periflow Laminar Flow Panels w/Perimeter Air Curtain
EHD-258
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
3/2006
Environmental/Hospital Diffusers
- 4
- 4
Duct Size
1
- 4
2 18
2 18
L = Overall Length
L = Overall Length
Duct Size
1
- 4
Back Pan
Perforated Face
1
4
3
8
Removable Perforated Face Panel
W = Overall Width3
Nominal Size + 1
L = Overall Length
2 18
3
8
EHD
Duct Size
L = Overall Length
2 18
Perforated Face
T-Bar Module -
3
8
1
4
Perforated Face
Perforated Face
3
1 8
Nominal Size + 1 4
Nominal Size + 1
1
4
1
8
T-Bar Module 4
T-Bar Module
-
3
8
Perforated Face
3
8
1
Nominal SizePerforated
+ 1 4 Face
T-Bar Module -
T-Bar Module
EHD-260
3
8
Perforated Face
Perforated Face
3
8
1
4
Nominal
Size
Frame 1
L
Frame 6
L
W
Perforated Face
Frame 6M
L
W
3
24 x 24
24 x 48
3
8
Duct Size
Duct Size
- 41
1
28
Duct Size
- 41
= Module
C = Ceiling Opening
Back
Pan Size
28
Removable Perforated
Face Panel
Removable Perforated
Removable Perforated
Face Panel
Nominal Size + 1
28
L = Overall Length
L = Overall Length
Face Panel
W = Overall Width
W = Overall Width
Face
Panel
W = Overall
Width
- 41
L = Overall Length
T-Bar Module - 1
1
4
ModuleOpening
Size
C = Ceiling Opening
= Module Size
C ==Ceiling
Removable Perforated
Removable Perforated
Face Panel
Face Panel
Removable Perforated
Removable Perforated
Face Panel
Face Panel
Removable Perforated
Face Panel
3
T-Bar Module - 8
T-Bar Module = Nominal Size
Environmental/Hospital Diffusers
BackpanBack Pan
Nominal
Size
Frame 1
Frame 6
LRemovable
WPerforated
L
W
Face Panel
Frame 6M
L
W
12 x 36
12 x 48
12 x 48T-Bar
49 1/4
1/8 47Size
3/4 11 3/4 47 3/4 11 3/4
Module13
= Nominal
24 x 24
24 x 36
24 x 48
T-Bar Module -
EHD
3/2006
Removable Perforated
Removable Perforated
Face Panel
Face Panel
3
T-Bar Module - 8 T-Bar Module - 3
8
T-Bar Module = Nominal
Size = Nominal Size
T-Bar Module
4
Removable Perforated
Face Panel
3
T-Bar Module - 8
T-Bar Module = Nominal Size
EHD-261
Back Pan
Back Pan
2
2
4
4
L = Overall Length
L = Overall Length
Duct Size
- 41
Pan
C = Ceiling Opening =Back
Module
Size
Face Panel
L = Overall Length
Environmental/Hospital Diffusers
Nominal Size + 1 41
T-Bar Module - 1
4
4
4
4
Removable Perforated
Removable
Face
Panel Perforated
Face Panel
T-Bar Module - 1
1
T-Bar Module - 4
4
T-Bar Module = Nominal Size
T-Bar Module = Nominal Size
Removable Perforated
Removable
Face
Panel Perforated
Face Panel
Nominal Size + 1 411
Nominal Size + 1 4
EHD
Removable Perforated
Face Panel
W = Overall
WidthPerforated
Removable
Removable Perforated
Face Panel
Nominal Size + 41 41
Removable Perforated
Face Panel
T-Bar Module - 3
8
T-Bar Module = Nominal Size
Nominal
Size
Frame 1
L
Removable Perforated
FaceLPanel W
Frame 6
Frame 6M
L
W
24 x 24
24 x 48
2. Available Accessories
D3 - Aluminum Radial Opposed Blade Damper
SD3 - Steel Radial Opposed Blade Damper
RSD - Radial Shutter Damper
CD - Cable Damper
4
4
3. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
Removable Perforated
Removable Perforated
Face HPL-CL-SA-6,
Panel
Notes for Models HPL-CL-SA-1,
HPL-CL-SA-6M
Face Panel
1. Available Finishes
Standard Finish:
23 #3 Scratch
T-Bar Module - 33
T-Bar Module - 8
8
T-Bar Module = Nominal Size
T-Bar Module = Nominal Size
2. Available Accessories
3. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
EHD-262
3/2006
Removable Perforated
2. Available Accessories
Face Panel
3
D3 - Aluminum Radial Opposed Blade Damper
T-Bar Module 8
T-Bar Module = Nominal SizeSD3 - Steel Radial Opposed Blade Damper
RSD - Radial Shutter Damper
CD - Cable Damper
3. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
3/2006
CFM Per
SQ. Foot
20
30
40
50
60
70
80
90
100
0.010
0.021
0.038
0.060
0.086
0.117
0.152
0.193
0.005
0.011
0.020
0.031
0.045
0.061
0.080
0.101
<15
<15
<15
21
25
31
34
39
0.004
0.010
0.017
0.027
0.038
0.052
0.068
0.086
0.107
<15
<15
<15
18
22
24
30
35
39
<15
<15
18
21
29
35
38
40
0.193
40
0.101
39
0.086
35
NC Correction
0.107
39
Environmental/Hospital Diffusers
Single Panel
Mult. Panels (1)
Mult. Panels (2)
10
20
20
25
20
35
35
40
30
50
50
60
60
80
90
110
70
90
100
120
80
100
110
130
EHD
Performance Notes:
Average velocity is in feet per minute and is based on readings 6 feet below panels using a 15 F temperature differential (cooling).
Multiple panels: (1) Average velocity for adjacent panels totaling 15 to 30 square feet.
(2) Average velocity for adjacent panels totaling 30 plus square feet.
EHD-263
3/2006
Environmental/Hospital Diffusers
EHD
Units shall have round inlets. Units shall be designed to integrate into the specified ceiling system. The units shall be the size and quantity as outline in the
plans and specifications.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Finish Specification
Aluminum Face Diffusers: Units shall be painted with a powered coat, baked on epoxy.
Stainless Steel Face Diffusers: # 3 Scratch Finish
EHD-264
3/2006
Inlet
Module
Free Area
6"
24" x 12"
51%
D3
8"
36" x 12"
40%
SD3
9"
48" x 12"
23%
10"
60" x 12"
12"
72" x 12"
14"
24" x 24"
- Surface Mount
HPL-CL-AL-6
- T-bar Lay-in
- Surface Mount
HPL-CL-SS-6
- T-bar Lay-in
- Surface Mount
HPL-CL-SA-6
- T-bar Lay-in
Available Options
36" x 24"
48" x 24"
60" x 24"
72" x 24"
48" x 36"
EHD
Environmental/Hospital Diffusers
HPL-CL-AL-1
Available Finishes
EHD-265
3/2006
Environmental/Hospital Diffusers
2 81
3 9
Removable Perforated
Face Panel
The diffuser is available
with a choice of three free
W = Overall Width
areas for the perforated face: 23%, 40% and 51%
maximizing the range of capacities for the HPL.
The HPL is also available in aluminum or stainless
steel construction
Filter Frame
HEPA
FilterHEPA
Frame
Optional HEPA
filters
are
available
Back PanBack Pan
Duct Size - 41
L = Overall Length
2 81
2 81
1
Size - 4
Duct Size - Duct
4
EHD
3 9
3 9
Back Pan
3 9
= Overall Length
L = OverallLLength
HEPA Filter
2 81
Duct Size - 41
3 9
3 9
Removable Perforated
Face Panel
Removable Perforated
Face Panel
Removable Perforated
Nominal Size
+ Panel
1 41
Face
W = Overall Width
T- Bar Module -
L = Overall Length
1
4
= Ceiling
OpeningSize
= Module Size
C = Ceiling C
Opening
= Module
3 9
3 9
3 9
3 9
Removable Removable
Perforated Perforated
Face Panel Face Panel
1
TBar
T- Bar Module - 41 Module - 4
RemovableRemovable
Perforated Perforated
Face PanelFace Panel
1
Nominal
Nominal Size + 1 1 Size + 1 4
4
Removable Perforated
3 9
Face Panel
Nominal Size + 1 41
3 9
Nominal
Size
Frame 1
L
24 x 24 25 1/8 25 1/8
23 3/4 23 3/4 23 5/8 23 5/8
T- Bar Module - 1
24 x 48
3
8
EHD-266
Face Panel
Frame 6M
L
W
24 x 24
Removable Perforated
Face Panel
T- Bar Module -
Frame 6
W Removable
L PerforatedW
HEPA Filter
HEPA Filter
Perforated
FaceRemovable
Panel
C = Ceiling
HEPA
Filter Opening
Frame = Module Size
Back Pan
Duct Size - 41
Duct Size - 41
2 81
2 81
L = Overall Length
L = Overall Length
2 81
HEPA Filter
Duct Size - 41
L = Overall Length
W = Overall Width
T-Bar Module - 41
Removable Perforated
Face Panel
Removable Perforated
Face Panel
Removable
Perforated
Face Panel
Nominal
Size + 1 41
Removable Perforated
Perforated
Face Removable
Panel
Face Panel
T-Bar Module - 41
T-Bar Module - 41
T-Bar Module = Nominal Size
T-Bar Module = Nominal Size
Removable Perforated
Perforated
FaceRemovable
Panel
Face Panel
Nominal Size + 1 41
Nominal Size + 1 41
1
Nominal Size + 1 3
4
Nominal
Size
Frame 1
L
24 x 24
24 x 24 25 1/8
24 x 48
24 x 48 49 1/8
Removable Perforated
Frame
Face Panel
T-Bar
WModule - 41L
6
W
Frame 6M
L
W
25 1/8
23 3/4
23 3/4
23 3/4
23 3/4
25 1/8
47 3/4
23 3/4
47 3/4
23 3/4
EHD
3/2006
Removable Perforated
Face Panel
T-Bar Module - 38
Removable Perforated
Perforated
FaceRemovable
Panel
Face Panel
T-Bar Module - 38
T-Bar Module - 38
T-Bar Module = Nominal Size
T-Bar Module = Nominal Size
Removable Perforated
Face Panel
T-Bar Module - 38
EHD-267
2
Removable Perforated Face Panel
W = Overall Width
L = Overall Length
Back
Back Pan
HEPA Filter
Pan
Duct Size
11
-24
8
Duct Size
1
-4
1
28
1
92
1
92
Removable Perforated Face Panel
Removable Perforated Face Panel
W = Overall Width
W = Overall Width
HEPA Filter Frame
HEPA Filter
HEPA Filter
Back Pan
L = Overall Length
L = Overall Length
Duct Size
1
28
1
-4
1
92
Environmental/Hospital Diffusers
W = Overall Width 3
3/2006
1
92
1
92
L = Overall Length
Removable Perforated
Removable Perforated
Hospital Diffuser - Laminar Flow
- With HEPA Filter Cell
Face Panel
Surface Mount - Stainless Steel
NominalFace
Size + 1&41 Backpan
Model HPL-HA-SS-1
Panel
Hospital Diffuser -Face
Laminar
Flow - With HEPA Filter Cell
1
T-Bar Module Standard T-bar Lay-in
- Stainless
Steel Face & Backpan
4
T-Bar Module = Nominal Size
Model HPL-HA-SS-6
1
92
1
92
EHD
1
92
Removable Perforated
Removable Perforated
Face Panel
Face Panel
1
1 T-Bar Module - 4
T-Bar Module 4
T-Bar Module = Nominal Size
T-Bar Module = Nominal Size
Removable Perforated
Removable Perforated
Face Panel
Face Panel
Nominal Size + 1 41
Nominal Size + 1 41
Nominal Size + 1
1
92
Nominal
Size
1
4
1
92
Removable Perforated
Frame
1
Face Panel
LT-Bar ModuleW- 41
1
92
Frame 6
L
W
Frame 6M
L
W
24 x 24
Nominal Size
24 x 24T-Bar
25Module
1/8 = 25
1/8 23 3/4 23 3/4 23 3/4 23 3/4
24 x 48
Removable Perforated
Face Panel
T-Bar Module - 38
2. Available Accessories
CD - Cable
Damper
3
91
2
3. Available Options
1
92
HEPA Filter
TP Test Port
Removable Perforated
Removable Perforated
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
Face Panel
Panel
Notes for Models HPL-HA-SA-1,Face
HPL-HA-SA-6,
HPL-HA-SA-6M
T-Bar Module - 3
1. Available Finishes
Standard Finish:
23 #3 scratch
8
T-Bar Module - 38
Module =Accessories
Nominal Size
2.T-Bar
Available
T-Bar Module = Nominal
Size
CD - Cable Damper
3
1
92
3. Available Options
HEPA Filter
TP Test Port
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
EHD-268
Removable Perforated
Face2.Panel
Available Accessories
T-Bar Module - 38
T-Bar ModuleCD
= Nominal
- Cable Size
Damper
3. Available Options
HEPA Filter
TP Test Port
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
3/2006
0.010
0.021
0.038
0.060
0.086
0.117
0.152
0.193
0.005
0.011
0.020
0.031
0.045
0.061
0.080
0.101
0.004
0.010
0.017
0.027
0.038
0.052
0.068
0.086
0.107
<15
<15
18
21
29
35
38
40
<15
<15
<15
21
25
31
34
39
<15
<15
<15
18
22
24
30
35
39
20
30
40
50
60
70
80
90
100
EHD
CFM Per
SQ. Foot
EHD-269
3/2006
EHD
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Finish Specification
Aluminum Face Diffusers: Units shall be painted with a powered coat, baked on epoxy.
Stainless Steel Face Diffusers: # 3 Scratch Finish
EHD-270
3/2006
Inlet
Module
Free Area
6"
24" x 12"
51%
D3
8"
36" x 12"
40%
SD3
23%
HEPA
TP
Test Ports
9"
48" x 12"
10"
60" x 12"
12"
72" x 12"
14"
24" x 24"
Available Options
36" x 24"
48" x 24"
60" x 24"
72" x 24"
48" x 36"
EHD
Environmental/Hospital Diffusers
Available Finishes
EHD-271
3/2006
L = Overall Length
Duct Size - 41
3 9
L = Overall Length
HEPA Filter
HEPA Filter
1
4
Duct Size - 41
Distribution
Panel
2
Distribution
Panel
Attached
To Attached To
RemovableFace
Perforated
Removable Perforated
Panel Face Panel
EHD
3 9
HEPA Filter
Duct Size - 41
L = Overall Length
L = Overall Length
Removable Perforated
C = Ceiling
Panel Opening = Module Size
Face
HEPA Filter Frame
1
4
Nominal Size + 1
Back Pan
3 9
HEPA Filter
Duct Size - 41
NominalFace
SizePanel
+1 1
W = Overall 4Width
Removable Perforated
Face Panel
1
Distribution Panel Attached To T- Bar Module - 4
Removable Perforated Face Panel
3 9
3 9
Removable Perforated
Face
Panel Perforated
Removable
3 9
3 9
Removable Perforated
Face Panel
T- Bar Module -
L = Overall Length
1
4
3 9
3 9
3 9
3 9
Removable Perforated
Removable Perforated
Face Panel
Face Panel
1
T1 Bar Module - 4
T- Bar Module - 4
Removable Perforated
Removable Perforated
Face Panel
Face Panel
Nominal
Size + 1 41
1
Nominal Size + 1 4
C = Ceiling Opening = Module Size
3 9
3 9
Removable Perforated
Face Panel
Nominal Size + 1
1
4
Removable Perforated
Face Panel
Removable Perforated
Face Panel
3 9
T- Bar Module - 83
Removable
Perforated
T- Bar Modu
le = Nominal
Size
Face Panel
T- Bar Module - 83
EHD-272
T- Bar Module -
1
4
W = Overall Width
L = Overall Length
-4
-4
2
Distribution
Panel
Distribution
Panel
Attached
To Attached To
RemovableFace
Perforated
Removable Perforated
Panel Face Panel
92
3 Width
= Overall
W = OverallW
Width
92
Perforated
RemovableFace
Panel Face Panel
Removable Perforated
Back Pan
Removable Perforated
Face Panel C = Ceiling Opening = Module Size
= Overall Length
L = Overall
DuctLLength
Size
2
-4
HEPA Filter
Face Panel
W = Overall Width
Removable Perforated
Face Panel
Nominal Size + 1 1
Hospital Diffuser - Patient Room Isolation
4
Surface Mount - Stainless Steel Face & Aluminum Backpan
Model HPL-PR-SA-1
1
4
1
T-Bar9Module
= Nominal Size
2
3
9 12
92
9 12
Perforated
T-Bar Module -
1
4
Nominal Size + 1
92
L = Overall Length
Removable Perforated
Face Panel
T-Bar Module -
1
4
Opening
= Module Size
C = Ceiling
= Module
Size
C = Ceiling Opening
T-Bar ModuleT-Bar
- 1 Module -
1
+ 1 1 Size + 1 4
Nominal SizeNominal
92
T-Bar Module - 1
Removable Perforated
Face Panel
9 12
Removable Perforated
Cross Section:
Diffuser Face
Face Panel
9 124
Nominal Size + 1
1
4
ModuleSize
= Nominal Size
T-Bar ModuleT-Bar
= Nominal
Face Panel
9 12
Removable Perforated
Removable Perforated
Face Panel Face Panel
Removable Perforated
Removable Perforated
= Ceiling
Opening = Module Size
Panel
Face PanelC Face
9 12
92
EHD
92
3/2006
9 12
T-Bar Module - 8
Removable
Perforated
T-Bar Module = Nominal
Size
Face Panel
T-Bar Module - 38
Nominal
Size
Removable Perforated
Removable Perforated
Face Panel Face Panel
3
3
T-Bar ModuleT-Bar
- 8 Module - 8
Module
= Nominal Size
T-Bar ModuleT-Bar
= Nominal
Size
9 12
One Way
1W
Way
Two WayT-Bar ModuleThree
= Nominal
Size
3W
2W
Frame 1
L
Four Way
4W
Frame 6
L
W
Frame 6M
L
W
12 x 36
12 x 36 37 1/8
13 1/8
35 3/4
11 3/4
35 3/4
11 3/4
12 x 48
12 x 48 49 1/4
13 1/8
47 3/4
11 3/4
47 3/4
11 3/4
Pattern
Control Blades
Fixed PatternFixed
Control
Blades
Removable Perforated
Face Panel
T-Bar Module - 8
24 x 24
24 x 24 25 1/4
24 x 36
24 x 48
RemovableFace
Perforated
Removable Perforated
Panel Face Panel
Aluminum Aluminum
25 1/8
23 3/4
23 3/4
23 3/4
23 3/4
24 x 36 37 1/8
25 1/8
35 3/4
23 3/4
35 3/4
23 3/4
24 x 48 49 1/8
25
1/8 47 3/4 23 3/4
Removable Perforated Face Panel
47 3/4
23 3/4
Aluminum
EHD-273
W = Overall Width
L = Overall Length
-4
-4
2
Distribution
Panel
Distribution
Panel
Attached
To Attached To
RemovableFace
Perforated
Removable Perforated
Panel Face Panel
Back Pan
Removable Perforated
Face Panel C = Ceiling Opening = Module Size
= Overall Length
L = Overall
DuctLLength
Size
2
-4
HEPA Filter
Face Panel
Removable Perforated
Face Panel
Nominal Size + 1 1
Hospital Diffuser - Patient Room Isolation
4
Surface Mount - Stainless Steel Face & Backpan
Model HPL-PR-SS-1
1
4
1
T-Bar9Module
= Nominal Size
2
3
9 12
92
9 12
Perforated
T-Bar Module -
1
4
W = Overall Width
92
Perforated
RemovableFace
Panel Face Panel
Removable Perforated
Nominal Size + 1
92
92
3 Width
= Overall
W = OverallW
Width
3/2006
L = Overall Length
Removable Perforated
Face Panel
T-Bar Module -
1
4
Opening
= Module Size
C = Ceiling
= Module
Size
C = Ceiling Opening
T-Bar ModuleT-Bar
- 1 Module -
1
+ 1 1 Size + 1 4
Nominal SizeNominal
92
EHD
9 12
Removable Perforated
Cross Section:
Diffuser Face
Face Panel
T-Bar Module - 1
9 124
Nominal Size + 1
1
4
ModuleSize
= Nominal Size
T-Bar ModuleT-Bar
= Nominal
Face Panel
9 12
Removable Perforated
Removable Perforated
Face Panel Face Panel
Removable Perforated
Removable Perforated
= Ceiling
Opening = Module Size
Panel
Face PanelC Face
9 12
92
92
Removable Perforated
Face Panel
9 12
T-Bar Module - 8
Removable
Perforated
T-Bar Module = Nominal
Size
Face Panel
T-Bar Module - 38
Air Patterns
9 12
Removable Perforated
Removable Perforated
Face Panel Face Panel
One Way
1W
3
3
T-Bar ModuleT-Bar
- 8 Module - 8
Module
= Nominal Size
T-Bar ModuleT-Bar
= Nominal
Size
Two Way
2W
Three Way
Removable3W
Perforated
Face Panel
Nominal
Size
9 12
9 12
Four Way
4W
Frame 1
L
Frame 6
L
W
12 x 36
12 x 36 37 1/8
13 1/8
35 3/4
11 3/4
35 3/4
11 3/4
12 x 48
12 x 48 49 1/4
13 1/8
47 3/4
11 3/4
47 3/4
11 3/4
24 x 24
24 x 24 25 1/4
25 1/8
23 3/4
23 3/4
23 3/4
23 3/4
24 x 36
24 x 36 37 1/8
25 1/8
35 3/4
23 3/4
35 3/4
23 3/4
Pattern
Control Blades
Fixed PatternFixed
Control
Blades
24 x 48
24 x 48 49 1/8
RemovableFace
Perforated
Removable Perforated
Panel Face Panel
Aluminum Aluminum
25 1/8
47 3/4
23 3/4
T-Bar Module - 8
EHD-274
Frame 6M
L
W
47 3/4
23 3/4
3/2006
2. Available Options
Standard Finish:
08 White epoxy powder coat
3. Construction Details
HEPA Filter
CD - Cable Operated Damper
TP - Test Port
2. Available Options
Standard Finish:
08 White epoxy powder coat - Backpan/23 3 scratch - Face
3. Construction Details
HEPA Filter
CD - Cable Operated Damper
TP - Test Port
1. Available Finishes
2. Available Options
Standard Finish:
23 #3 scratch
3. Construction Details
20
0.003
<17
1-1-3
30
0.007
<17
1-1-4
40
0.013
17
1-2-6
50
0.020
21
1-3-8
60
0.028
<28
2-4-10
70
0.039
34
2-5-11
80
0.051
37
3-6-13
90
0.064
40
5-8-16
100
0.079
41
6-10-20
20
30
40
50
60
70
80
90
100
Ps
0.150
0.240
0.334
0.425
0.523
0.625
0.730
0.820
NC
<24
<24
29
32
35
39
42
45
Throw
1-1-3
1-1-4
1-2-6
1-3-8
2-4-10
2-5-11
3-6-13
5-8-16
EHD
EHD-275
3/2006
Environmental/Hospital Diffusers
Performance Specification
EHD
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Finish Specification
Aluminum Face Diffusers: Units shall be painted with a powered coat, baked on epoxy.
Stainless Steel Face Diffusers: # 3 Scratch Finish
EHD-276
3/2006
Inlet
Module
Free Area
6"
24" x 12"
51%
8"
36" x 12"
40%
23%
9"
48" x 12"
10"
60" x 12"
12"
72" x 12"
14"
24" x 24"
Air Patterns
08 - White epoxy
(aluminum face)
1W - One Way
23 - #3 scratch
(stainless steel face)
Available Options
D3
SD3
HEPA
TP
Test Ports
3W - Three Way
4W - Four Way
36" x 24"
48" x 24"
60" x 24"
72" x 24"
48" x 36"
EHD
Environmental/Hospital Diffusers
Available Finishes
EHD-277
3/2006
Environmental/Hospital Diffusers
Duct Size
1
- 4
Back Pan
2 18
L = Overall Length
Back Pan
3
8
2 18
Duct Size
1
- 4
2 18
Perforated Face
8
3
8
1
4
Nominal Size + 1
L = Overall Length
L = Overall Length
Back Pan
W = Overall Width
EHD
- 4
2 18
3
8
Duct Size
- 4
T-Bar Module -
L = Overall Length
Perforated Face
3
8
1
4
Perforated Face
Nominal Size + 1
Perforated Face
1 8
4
Nominal
Size + 1
1
4
T-Bar Module -
3
8
Perforated Face
1
8
4 T-Bar Module -
Perforated Face
1
4
3
8
Nominal Size + 1
T-Bar Module
3
8
Perforated Face
24 x 24
Frame 1
Frame 63
Frame 6M
1
8
T-Bar Module C
L
W
L 4
W
L
W
24 x 24 25 1/4 25 1/4 23 3/4 23 3/4 23 3/4 23 3/4
24 x 48
Nominal
Size
3
8
Perforated Face
T-Bar Module -
EHD-278
1
4
3
8
-4
Back Pan
3
8
L = Overall Length
C = Ceiling Opening
C = Ceiling Opening
Duct Size
Duct Size
-1
Back Pan
Back Pan
W = Overall Width
W = Overall Width
28
28
W = Overall Width
3
8
L = Overall Length
3
8
Outside
1
Ceiling Opening
Module
Nominal=Size
+ 1 Size
Perforated Face
Outside 4
Nominal Size + 1 14
Perforated Face
Inside Perforated Face
1
4
3
8
T-Bar Module -
T-Bar Module
3
8
3
8
3
8
Outside
1
T-Bar Module
Perforated Face
Outside
4
1
T-Bar Module
- ModulePerforated Face
T-Bar
4 Inside Perforated Face
T-Bar Module
Nominal
Size
3
8
3
8
Nominal Size + 1
Removable Perforated
Face Panel
4
3
8
L = Overall Length
Duct Size
L = Overall Length
- 41
Back Pan
28
Removable Perforated
Panel
Opening
C = CeilingFace
Removable Perforated Face Panel
3
8
3
8
- 41
W = Overall Width
3
8
1
4
Outside
Frame
6
Perforated Face
L
W
Frame 6M
L
W
24 x 24
24 x 48
EHD
3/2006
28
Outside
Perforated Face
3
8
Outside
T-Bar Module 8
3
Outside
Perforated Face
T-Bar Module
T-Bar
8 Module
Perforated
FaceFace
Inside
Perforated
T-Bar Module
3
8
Vertical Throw
3
T-Bar Module 8
T-Bar Module
Outside
Perforated Face
Horizontal Spread
EHD-279
Back Pan
2 18
3
8
W = Overall Width
C = Ceiling Opening
C = Ceiling Opening
Duct Size
Duct Size
-1
4
1
-4
2 18
2 18
3
8
3
8
W = Overall Width
Environmental/Hospital Diffusers
L = Overall Length
3
8
3
8
3
8
3
8
EHD
Outside
Perforated Face
1
4
3
8
T-Bar Module -
T-Bar Module
3
8
3
8
3
8
Outside
T-Bar Module
- 14
Outside
Perforated Face
1
T-Bar Module
- Module
4
T-Bar
Perforated Face
Outside
Nominal
Size= +Module
1 1
Ceiling
Opening
Outside 4 Size
Perforated Face
Nominal Size + 1 14
Perforated Face
Nominal Size + 1
L = Overall Length
Size
L = Overall Duct
Length
1
-4
2 18
Back Pan
3/2006
L = Overall Length
T-Bar Module
Nominal
Size
3
8
1
4
Outside
Frame
6Face
Perforated
L
W
Frame 6M
L
W
24 x 24
24 x 48
Outside
Perforated Face
1. Available Finishes
4
Standard Finish:
08 White epoxy powder coat
Inside Perforated
Face
2. Available
Accessories
3 blade damper
D3 - Aluminum radial opposed
8
3
8 opposed blade damper
SD3 - Steel radial
RSD - Radial shutter damper
T-Bar Module -
3. Available Options
One way (90 discharge pattern)
Two way (180 discharge patern)
4. Construction Details
Perforated faces are shipped with 2 safety cables
51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
Outside
8
3 HRD-CL-SA-6M
Outside
Perforated Face
Notes for Models HRD-CL-SA-1, HRD-CL-SA-6,
T-Bar Module
T-Bar
8 Module
1. Available Finishes
Standard Finish:
23 #2B scratch
Perforated Face
Inside Perforated Face
T-Bar Module
2. Available Accessories
3. Available Options
One way (90 discharge pattern)
Two way (180 discharge patern)
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
3
Outside
T-Bar Module
Notes for Models HRD-CL-SS-1, HRD-CL-SS-6,
HRD-CL-SS-6M
8
Perforated Face
T-Bar Module
1. Available Finishes
Standard Finish:
23 #2B scratch
EHD-280
2. Available Accessories
D3 - Aluminum radial opposed blade damper
SD3 - Steel radial opposed blade damper
RSD - Radial shutter damper
3. Available Options
One way (90 discharge pattern)
Two way (180 discharge patern)
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
3/2006
24" x 24"
8" Inlet
24" x 24"
10" Inlet
24" x 48"
10" Inlet
24" x 48"
12" Inlet
150
200
250
300
400
500
0.019
0.033
0.052
0.075
0.133
0.207
0.030
0.054
0.084
0.121
0.215
0.335
<15
<15
18
23
32
39
300
400
500
600
800
900
0.03
0.053
0.083
0.12
0.212
0.269
0.049
0.087
0.135
0.195
0.347
0.439
<15
19
28
34
40
40
250
325
400
475
550
625
500
600
700
800
900
1000
0.021
0.035
0.053
0.075
0.1
0.13
0.048
0.07
0.095
0.124
0.157
0.194
0.034
0.057
0.087
0.122
0.164
0.212
0.074
0.106
0.145
0.189
0.239
0.295
<15
<15
21
27
33
37
19
25
30
33
39
42
100
1
1
2
3
3
4
0
0
1
1
2
3
1
2
3
4
5
6
1
1
2
2
3
3
10 Deg dT
10 Deg dT
75
50
100
75
50
100
2
3
4
5
5
6
5
6
7
8
8
9
0
0
0
1
1
1
0
1
1
1
2
2
1
2
4
4
5
5
1
1
2
2
2
2
1
1
2
3
4
5
2
4
5
6
7
7
2
3
3
4
4
5
3
2
5
5
6
7
6
7
7
8
9
10
5
6
7
8
8
9
0
0
1
1
2
2
0
0
1
1
1
2
1
1
1
2
2
3
1
1
2
2
3
4
0
1
1
2
3
3
1
2
3
3
4
4
2
2
4
4
5
5
2
3
4
5
6
7
4
5
6
6
7
8
0
0
1
1
2
3
1
1
2
2
3
3
1
1
1
2
2
3
15 Deg dT
20 Deg dT
75
50
100
75
50
1
2
2
3
3
4
3
4
5
5
6
7
0
1
1
1
2
2
1
1
2
3
3
4
3
4
5
5
6
7
1
1
2
2
4
5
2
2
3
3
5
5
1
2
3
4
5
6
2
2
5
5
6
7
0
0
1
2
3
4
3
5
6
7
8
9
0
1
1
1
2
3
6
7
8
9
10
10
1
2
2
3
4
4
1
1
3
4
5
6
1
1
2
3
5
6
3
4
4
5
5
6
4
3
6
6
7
8
3
5
6
7
10
10
6
7
9
10
11
11
Environmental/Hospital Diffusers
1-Way Pattern
Module Size
and
Ps
Pt
Air Flow
Inlet Size
(CFM) (in wc.) (in wc.)
2-Way Pattern
Module Size
and
Ps
Pt
Air Flow
Inlet Size
(CFM) (in wc.) (in wc.)
24" x 24"
8" Inlet
24" x 24"
10" Inlet
24" x 48"
10" Inlet
24" x 48"
12" Inlet
150
200
250
300
400
500
0.019
0.033
0.052
0.075
0.132
0.207
0.030
0.054
0.084
0.121
0.214
0.335
<15
15
19
23
31
39
250
325
500
600
700
900
0.017
0.028
0.067
0.096
0.131
0.217
0.030
0.050
0.119
0.172
0.234
0.387
<15
<15
26
33
38
42
250
325
500
600
700
900
500
600
700
800
900
1000
0.023
0.039
0.092
0.133
0.181
0.299
0.067
0.096
0.131
0.171
0.217
0.268
0.036
0.061
0.145
0.208
0.284
0.469
0.092
0.133
0.181
0.236
0.299
0.369
<15
<15
29
36
41
45
19
25
30
33
39
42
100
1
1
3
4
5
6
0
1
1
1
2
3
1
1
3
4
5
6
3
4
5
5
6
3
10 Deg dT
10 Deg dT
75
50
100
75
50
100
2
3
5
6
7
9
5
6
10
11
12
14
0
0
1
1
1
2
0
1
1
2
3
4
1
2
4
5
6
8
1
1
2
2
3
3
10
11
12
13
14
10
1
1
2
3
4
5
2
3
5
6
7
9
5
6
7
8
9
5
3
4
5
5
6
7
5
6
10
11
12
14
0
0
1
1
2
2
0
0
1
1
1
2
1
1
1
2
2
2
1
1
2
2
3
4
0
0
1
2
2
3
1
2
3
3
3
4
2
3
4
4
6
6
1
2
4
4
5
6
4
4
5
7
7
7
0
0
1
1
2
3
0
1
2
2
2
3
1
1
1
2
2
3
15 Deg dT
20 Deg dT
75
50
100
75
50
1
2
3
3
4
5
3
4
6
7
7
8
0
1
1
2
2
3
1
1
3
3
4
5
3
4
6
7
8
9
1
1
2
2
4
5
1
2
2
3
3
4
1
2
3
4
4
5
2
4
5
5
6
7
2
3
5
6
6
7
5
6
7
7
8
8
0
1
1
2
3
4
0
0
1
1
2
3
1
2
2
3
3
4
1
2
3
4
5
6
1
1
2
3
3
4
3
3
4
5
5
6
4
5
6
6
7
8
EHD
Models HRD-CL-AL (-1, -6, -6M), HRD-CL-SS (-1, -6, -6M), HRD-CL-SA (-1, -6, -6M)/2-Way Pattern
2
3
5
6
7
8
6
7
8
9
9
10
EHD-281
3/2006
Environmental/Hospital Diffusers
EHD
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Finish Specification
Aluminum Face Diffusers: Units shall be painted with a powered coat, baked on epoxy.
Stainless Steel Face Diffusers: # 2B Mill Finish
EHD-282
3/2006
Inlet
Module
Discharge Pattern
6"
24" x 24"
90 - One Way
8"
48" x 24"
HRD-CL-AL-1
- Surface Mount
HRD-CL-AL-6
- T-bar Lay-in
- Surface Mount
HRD-CL-SS-6
- T-bar Lay-in
Available Finishes
Available Options
D3
SD3
9"
10"
12"
14"
Environmental/Hospital Diffusers
- Surface Mount
HRD-CL-SA-6
- T-bar Lay-in
EHD
EHD-283
3/2006
EHD
Environmental/Hospital Diffusers
Product Details
The series HRD-HA radial discharge pattern
diffusers includes a HEPA filter section and are
engineered for supply air distribution in critical
environments such as chemistry labs and clean
rooms. The diffusers are engineered to supply a
low velocity of conditioned air in a radial pattern
from the ceiling
The series HRD-HA design includes a HEPA filter
cell accessible from the face of the diffuser. The
face and core assembly can be removed from the
face for cleaning. This feature allows the filters to
be removed and replaced from the diffuser face.
Optional HEPA filters are available
The HRD-HA Radial Discharge Pattern Diffusers
are easy to clean and sterilize. The face and core
assembly can be removed from the face for
cleaning. With the face and core assembly
removed, the interior of the backpan and inlet
collar are free of obstructions and easy to access
Back Pan
HEPA Filter
Back Pan
HEPA Filter
Back Pan
2 81
2 81
Duct Size - 41
Duct Size - 41
3 9
HEPA Filter
L = Overall Length
L = Overall Length
2 81
Duct Size - 41
3 9
Removable Perforated
Face Panel
W = Overall Width
L = Overall Length
3 9
3 9
Removable Perforated
Removable Face
Perforated
Panel
Face Panel
Nominal Size + 1 41
Nominal Size + 1 41
C = Ceiling Opening = Module Size
EHD-284
3 9
Removable Perforated
Removable Face
Perforated
Panel
Face Panel
T- Bar
Module - 41
T- Bar Module - 41
3 9
3 9
3 9
Removable Perforated
Face Panel
T- Bar Module -
C = Ceiling Opening
Duct Size
-1
4
Back Pan
Nominal
Size
3 9
3
8
Removable Perforated
Face Panel
T- Bar Module -
24 x 48
Back Pan
Back Pan
28
28
FaceOpening
Panel
Removable Perforated
C = Ceiling
Removable Perforated Face Panel
L = Overall Length
W = Overall Width
W = Overall Width
Duct Size
L = Overall Length1
-
Back Pan
28
3
9
Inside Perforated
Face
3
8
3
8
W = Overall Width
L = Overall Length
Outside
1
4
Frame 6M
L
W
24 x 24
C = Ceiling Opening
C = Ceiling Opening
Duct Size
Duct Size
-1
4
1
4
Nominal Size + 1
Frame 6
L
W
L = Overall Length
Frame 1
1
28L
8
W = Overall Width
T-Bar Module -
Outside
4 Face
Perforated Face
Radial Discharge Pattern T-Bar
- Removable
With HEPA Filter
Module
Standard T-bar Lay-in - Stainless Steel Face & Aluminum Backpan
Model HRD-HA-SA-6
Face
Radial Discharge Pattern - Removable Face With Perforated
HEPA Filter
Surface Mount - Stainless Steel Face & Aluminum Backpan
Model HRD-HA-SA-1
3
8
3
8
Outside
1
T-Bar Module 4
Perforated Face
Outside
1
T-Bar Module
- Module
T-Bar
Face
4 Inside Perforated
Perforated Face
T-Bar Module
3
8
3
8
T-Bar Module -
T-Bar Module
Nominal
Size
9
3
8
3
8
Outside
1
Nominal Size + 1 4
Perforated Face
Outside
1
Nominal Size + 1 4
Inside Perforated Face
9
Perforated Face
EHD
Frame 1
L
1
4
Outside
Perforated Face
Frame 6
L
W
Frame 6M
L
W
24 x 24
3
8
24 x 48
3
8
3/2006
Outside
Perforated Face
3
8
3 Perforated Face
Inside
8
3
8
3
Outside
T-Bar Module 8
3
Perforated Face
Module Outside
T-Bar ModuleT-Bar
3
8
Outside
T-Bar
Module Face
Perforated
T-Bar Module
T-Bar Module
Perforated Face
Vertical Throw
Horizontal Spread
EHD-285
28
1
92
W = Overall Width
L = Overall Length
C = Ceiling Opening
C = Ceiling OpeningDuct Size
Duct Size
-1
4
-1
4
Back Pan
Back Pan
2 18
92
92
Removable
Perforated
Face Panel
C = Ceiling
Opening
Removable Perforated Face Panel L = Overall Length
Duct Size
L = Overall Length
1
-4
Back Pan
Environmental/Hospital Diffusers
2 18
3
8
2 18
W Inside
= Overall
WidthFace
Perforated
3
8
9 21
3
8
91
2
3/2006
9 12
91
2
9 21
9 21
9 12
Nominal
Size + 1
Outside
1
Nominal Size + 1 4
OutsideInside Perforated
1
Face
Perforated
Face
4
Perforated Face
T-Bar Module - 4
1
T-Bar Module - T-Bar
Module
4
Outside
Inside
Perforated
Face
T-Bar Module
Perforated Face
9 21
3
8
T-Bar Module -
1
4
T-Bar Module
EHD
Nominal
Size
Outside
Perforated Face
3
8
91
2
3
8
3
8
Frame 1
L
1
4
Outside
Perforated Face
Frame 6
L
W
Frame 6M
L
W
24 x 24
24 x 24 25 1/8
25 1/8
23 3/4
23 3/4
23 3/4
23 3/4
3
8
24 x 48
24 x 48 49 1/8
25 1/8
47 3/4
23 3/4
47 3/4
23 3/4
3
8
Outside
Perforated Face
Standard Finish:
01 White
91
2
9 12
CD - Cable
Damper
3
8
T-Bar Module -
T-Bar Module 3
Outside
T-Bar Module
3
8
3
3
8
Outside
3. Available Options
One way (90 discharge pattern)
Two way (180 discharge patern)
HEPA Filter
4. Construction Details
Perforated faces are shipped with 2 safety cables
51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
Perforated Face
Outside
8 T-Bar Module - 8
Perforated
Face Perforated Face
Notes for Models HRD-HA-SA-1,
HRD-HA-SA-6,
HRD-HA-SA-6M
T-Bar
Module
T-Bar Module
1. Available Finishes
Standard Finish:
23 #2B scratch
2. Available Accessories
CD - Cable Damper
3. Available Options
One way (90 discharge pattern)
Two way (180 discharge patern)
HEPA Filter
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
EHD-286
2. Available Accessories
CD - Cable Damper
3. Available Options
One way (90 discharge pattern)
Two way (180 discharge patern)
HEPA Filter
4. Construction Details
Perforated faces are shipped with 2 safety cables
23%, 40%, 51% perforated face
Round neck sizes available: 6, 8, 10, 12 & 14
3/2006
24" x 24"
8" Inlet
24" x 24"
10" Inlet
24" x 48"
10" Inlet
24" x 48"
12" Inlet
150
200
250
300
400
500
0.019
0.033
0.052
0.075
0.133
0.207
0.030
0.054
0.084
0.121
0.215
0.335
<15
<15
18
23
32
39
300
400
500
600
800
900
0.03
0.053
0.083
0.12
0.212
0.269
0.049
0.087
0.135
0.195
0.347
0.439
<15
19
28
34
40
40
250
325
400
475
550
625
500
600
700
800
900
1000
0.021
0.035
0.053
0.075
0.1
0.13
0.048
0.07
0.095
0.124
0.157
0.194
0.034
0.057
0.087
0.122
0.164
0.212
0.074
0.106
0.145
0.189
0.239
0.295
<15
<15
21
27
33
37
19
25
30
33
39
42
10 Deg dT
10 Deg dT
20 Deg dT
100
75
50
100
75
50
100
75
50
100
75
50
1
1
2
3
3
4
2
3
4
5
5
6
5
6
7
8
8
9
0
0
0
1
1
1
0
1
1
1
2
2
1
2
4
4
5
5
1
1
2
2
2
2
1
2
2
3
3
4
3
4
5
5
6
7
0
1
1
1
2
2
1
1
2
3
3
4
3
4
5
5
6
7
0
0
1
1
2
3
1
2
3
4
5
6
1
1
2
2
3
3
1
1
2
3
4
5
2
4
5
6
7
7
2
3
3
4
4
5
3
2
5
5
6
7
6
7
7
8
9
10
5
6
7
8
8
9
0
0
1
1
2
2
0
0
1
1
1
2
1
1
1
2
2
3
1
1
2
2
3
4
0
1
1
2
3
3
1
2
3
3
4
4
2
2
4
4
5
5
2
3
4
5
6
7
4
5
6
6
7
8
0
0
1
1
2
3
1
1
2
2
3
3
1
1
1
2
2
3
1
1
2
2
4
5
2
2
3
3
5
5
1
2
3
4
5
6
2
2
5
5
6
7
0
0
1
2
3
4
3
5
6
7
8
9
0
1
1
1
2
3
6
7
8
9
10
10
1
2
2
3
4
4
1
1
3
4
5
6
1
1
2
3
5
6
3
4
4
5
5
6
4
3
6
6
7
8
3
5
6
7
10
10
6
7
9
10
11
11
Environmental/Hospital Diffusers
1-Way Pattern
Module Size
and
Ps
Pt
Air Flow
Inlet Size
(CFM) (in wc.) (in wc.)
2-Way Pattern
Module Size
and
Ps
Pt
Air Flow
Inlet Size
(CFM) (in wc.) (in wc.)
24" x 24"
8" Inlet
24" x 24"
10" Inlet
24" x 48"
10" Inlet
24" x 48"
12" Inlet
150
200
250
300
400
500
0.019
0.033
0.052
0.075
0.132
0.207
0.030
0.054
0.084
0.121
0.214
0.335
<15
15
19
23
31
39
250
325
500
600
700
900
0.017
0.028
0.067
0.096
0.131
0.217
0.030
0.050
0.119
0.172
0.234
0.387
<15
<15
26
33
38
42
250
325
500
600
700
900
500
600
700
800
900
1000
0.023
0.039
0.092
0.133
0.181
0.299
0.067
0.096
0.131
0.171
0.217
0.268
0.036
0.061
0.145
0.208
0.284
0.469
0.092
0.133
0.181
0.236
0.299
0.369
<15
<15
29
36
41
45
19
25
30
33
39
42
10 Deg dT
10 Deg dT
20 Deg dT
100
75
50
100
75
50
100
75
50
100
75
50
1
1
3
4
5
6
2
3
5
6
7
9
5
6
10
11
12
14
0
0
1
1
1
2
0
1
1
2
3
4
1
2
4
5
6
8
1
1
2
2
3
3
1
2
3
3
4
5
3
4
6
7
7
8
0
1
1
2
2
3
1
1
3
3
4
5
3
4
6
7
8
9
10
11
12
13
14
10
0
1
1
1
2
3
1
1
3
4
5
6
3
4
5
5
6
3
1
1
2
3
4
5
2
3
5
6
7
9
5
6
7
8
9
5
3
4
5
5
6
7
5
6
10
11
12
14
0
0
1
1
2
2
0
0
1
1
1
2
1
1
1
2
2
2
1
1
2
2
3
4
0
0
1
2
2
3
1
2
3
3
3
4
2
3
4
4
6
6
1
2
4
4
5
6
4
4
5
7
7
7
0
0
1
1
2
3
0
1
2
2
2
3
1
1
1
2
2
3
1
1
2
2
4
5
1
2
2
3
3
4
1
2
3
4
4
5
2
4
5
5
6
7
2
3
5
6
6
7
5
6
7
7
8
8
0
1
1
2
3
4
0
0
1
1
2
3
1
2
2
3
3
4
1
2
3
4
5
6
1
1
2
3
3
4
3
3
4
5
5
6
EHD
Models HRD-HA-AL (-1, -6, -6M), HRD-HA-SS (-1, -6, -6M), HRD-HA-SA (-1, -6, -6M)/2-Way Pattern
4
5
6
6
7
8
2
3
5
6
7
8
6
7
8
9
9
10
EHD-287
3/2006
Environmental/Hospital Diffusers
EHD
Units shall have round inlets. Units shall be designed to integrate into the specified ceiling system. The units shall be the size and quantity as outline in the
plans and specifications.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Finish Specification
Aluminum Face Diffusers: Units shall be painted with a powered coat, baked on epoxy.
Stainless Steel Face Diffusers: #2B Mill Finish
EHD-288
3/2006
Inlet
Module
Discharge Pattern
6"
24" x 24"
90 - One Way
8"
48" x 24"
HRD-HA-AL-1
- Surface Mount
HRD-HA-AL-6
- T-bar Lay-in
Available Finishes
Available Options
D3
SD3
12"
HEPA
14"
TP
Test Ports
9"
10"
Environmental/Hospital Diffusers
EHD
EHD-289
3/2006
EHD
Environmental/Hospital Diffusers
Product Details
The Periflow operating room air distribution
system provides control over particulate matter
within the operating room environment
The system has been tested in accordance with
the guidelines set forth by the Committee on
Operating Room Environments of the American
College of Surgeons as published in the January,
1976 Bulletin, and meets Class 1 Microbiological
Air Cleanliness guidelines. The system provides
the highest standard of air cleanliness for
patients undergoing minor procedures or
surgeries as critical as organ transplants
The system is in either stainless steel or heavy
aluminum construction to ensure long-term
durability and resistance to strong germicidal
solutions. In addition, each system is custom
designed and precisely fabricated to
accommodate the specialized medical,
mechanical, and electrical considerations of
todays operating room environments
EHD-290
+2 18
3/2006
C+2 8
B+2 78
E+2 18
14 78
D+2 78
D
B
B+2 78
15
15
A+2 78
E+2 18
F+2 81
15
15
15
A+2 78
C+2 8
C+2 8
F+2 81
15
14 78
15
F+2 81
12
EHD
12
3
4
Ceiling Level
14 78
F + 2 78
D + 2 78
Nominal
Duct Sizes
Model
84
104
124
85
105
125
86
106
126
108
128
148
12
A
8'
10'
12'
8'
10'
12'
8'
10'
12'
10'
12'
14'
Overall
Duct Sizes
Center Panel
Duct Sizes
B
C
D
E
4'
10' 6" 6' 6"
5'
4'
12' 6"D 6' 6"
6'
D
Duct
by 6"
Others
4' Work14'
6' 6"
8'
Duct Work by Others
12 5'
10'
6"
7'
6"
5'
12
5'
12' 6" 7' 6" 4 6'
14' 6" 7' 6"
8'
12 5'
6'
10' 6" 8' 6"
4'
Ceiling Level
6'
12' 6" Ceiling
8' 6" Level
5'
14 78
F + 2 78
7 6"
6' 1414'
8' 6"F + 2 77'
8
8
8'
12' D6"+ 2 10'
7'
7 6"
8
D + 2 78
8'
14' 6" 10' 6"
8'
8'
16' 6" 10' 6"
9'
F
2'
2'
1' 6"
2'
4 2'
1' 6"
3'
3'
2'
2'
2'
2'
CFM Range
800-1000
1000-2000
1100-2200
900-1800
1050-2010
3
1150-2300
3
4
4
1000-2000
1100-2200
1200-2400
1200-2400
1350-2700
1500-3000
EHD-291
3/2006
2. Construction Details
1. Available Finishes
Standard Finish:
AL Periflow: Exterior - White epoxy powder coat
Interior - Mill finish
SS Periflow: Exterior - Scratch
Interior - Smooth
AL Periflow:
SS Periflow:
Distance
in Feet
25
35
45
2'
40
42
45
4'
35
38
45
6'
28
32
35
Distance
in Feet
25
35
45
2'
110
120
130
4'
70
75
80
6'
35
50
65
EHD
Velocities are in Feet Per Minute (fpm) at the distance listed in feet from the face of the diffuser.
Values shown for center panels are average velocity; values shown for perimeter are peak velocity.
Center
Panel
Perimeter
Panel
25'
.067
.025
30'
.098
.035
35'
.130
.050
40'
.170
.060
45'
.210
.080
Static pressure values are in inches W.G. and are based on an inlet velocity of 500 fpm. Center panel values are based on
CFM per square foot of face panel and perimeter panels are based on CFM per lineal foot of panel.
Noise Criteria
CFM per Lineal Foot
of Perimeter Panel
NC
25'
<20
30'
23
35'
30
40'
34
45'
37
All values are based on Model 148 (44 perimeter feet) and a single center panel. Add one (1) NC for each additional four (4) lineal feet of perimeter panel.
Add three (3) NC for each additional four (4) square feet of center panel over a cumulative total of ten (10) square feet. All values are based on 10dB room
absorption and PWL dB ref. 10-12 watts. System NC values are based on 1/3 of total airflow to the center panels.
EHD-292
3/2006
= Required CFM
After determining the total CFM required, select the Periflow System with a mid-range CFM as close as possible to the total required CFM. The perimeter
system will receive two-thirds of the CFM. Selection of the mid supply will be maintained. Maximum recommended CFM per lineal foot perimeter
supply is 45.
Structural and Seismic Considerations
For structural and seismic calculations, the perimeter plenum system (including elbows) will weigh 12.7 lbs. per lineal foot and the center panels will weigh 7.6 lbs per
square foot.
EHD
Environmental/Hospital Diffusers
The above weights are based on the standard construction and plenum height as shown on the Periflow specification drawing.
4. A stainless steel perforated pressure plate supplied by the system manufacturer shall be permanently attached to both the center and perimeter panels to
provide equal air distribution over the diffuser face. Both center and perimeter panels shall be retained by quarter turn fasteners for ease of removal for
sterilization. The manufacturer shall supply clip-on safety cables to retain the face panels after the quarter turn fasteners are released.
5. An installation shall have been tested in accordance with the "Recommended Procedure for the Determination of Microbiological Air Cleanliness," as
published by the Committee on Operating Room Environment of the American College of Surgeons (January, 1976 Bulletin) by an Independent
Microbiological Testing Laboratory. The proposed system shall have met the requirements for Class 1 Microbiological Air Cleanliness as set forth in this
procedure. Copies of the Independent Laboratorys test report shall be provided to the engineer for prior approval. The manufacturer shall submit a listing
of 25 or more systems of the setup as shown.
6. Optional: The manufacturer shall provide the services of a qualified factory engineer or technician to supervise the balancing of the system(s). The
manufacturer shall provide a complete balancing report to the engineer within two weeks of completion of the system(s) balancing.
7. The air distribution and airborne article control system for the operating room(s) shall be the Periflow Operating Room System as manufactured by
METALAIRE or approved equal.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
EHD-293
3/2006
EHD
Environmental/Hospital Diffusers
The summary of the samples is presented in the table shown below. The air sampling results
are of bacterial colony counts per plate after 72 hours of incubation. Each sample represents
thirty cubic feet of air ( 30 Ft.3 )
Run*
Count at Operating
Table with Air Curtain
Count Outside
Air Curtain
1
3
4
5
6
0
1
4
5
6
Allowable
30 Max
1
3
4
5
6
2
0
0
2
7
0
5
6
0
0
1
0
Total
Allowable
4
2
3
7
0
13
83
2
4
24
30 Max
Allowable
1
2
3
24
30 Max
214
10
Allowable
Total
20
175
Total
Total
Six Stage
Impaction Samplers
1
1
0
2
30 Max
12
3
4
1
100
* Samples 1 through 3 were taken under simulated operating conditions. Sample four is a control sample.
EHD-294
3/2006
To decontaminate the system, first remove the center panel and perimeter face panels. This is done by turning the quarter turn fastener with a flathead
screwdriver to the unlocked position. The center panel and pressure plate that is attached is further secured by a safety cable and snap. Unsnap the safety
cable to complete the removal. The center panels can then be sterilized by immersion in a germicidal solution or placed in an autoclave if available.
With the face panels removed, the distribution plenums are now accessible. These are provided with round corners to facilitate cleaning. All surfaces
should be sterilized by wiping with a germicidal solution, including all duct work downstream of the HEPA filter. Failure to sterilize all components
downstream of the HEPA filter may result in contamination of the operating area by microbiologically active particles.
Once all components of the system are sterilized, the center panels can be reinstalled. Care should be taken not to contaminate the now sterilized center
panels during re-installation. Sterile clothing and gloves for maintenance personnel are recommended. Maintenance personnel should be instructed to
reattach the safety cable prior to securing the face panels to the plenum using the quarter turn fastener. Once the balancing and decontamination process
has been complete, the Periflow System is ready for use.
Maintaining the System
All components of the Periflow System are fabricated from stainless steel to provide years of durable use. It is essential that the decontamination process
listed above is repeated after the HEPA filters are changed.
While the Periflow System does not contain movable parts that require continual maintenance, an ongoing maintenance program is recommended. The
Periflow System is designed to minimize the accumulation of particulates and in that respect, is essentially self-cleaning. However, the possibility does
exist for the occasional contaminant to escape from the HEPA filter and become lodged in the system. It is recommended that the decontamination
process be repeated periodically, depending upon the usage of the particular operating room.
Environmental/Hospital Diffusers
Decontamination
After the system is balanced and before the system is placed into operation, all components of the system downstream of the HEPA filter (including duct
work) must be decontaminated. All face panels (both center and perimeter) are supplied with quarter turn fasteners on staggered centers. The fasteners
are staggered to prevent improper installation of the center panels.
The Periflow System has been designed to provide the most efficient operating room air distribution system available while minimizing usage of ceiling
space. To ensure proper installation, a drawing illustrating the assembly and installation details must accompany each Periflow submittal.
EHD
A few of the design features of the Periflow System which contribute to the ease of assembly and installation are as follows:
Perimeter plenums are shipped in maximum lengths of 12 and supplied with pre-drilled flanges at either end. Longer sections are also flanged and
supplied with pre-drilled bolt holes for connecting sections.
Connecting elbows are flanged to meet the flanges at either end of the perimeter plenum (also supplied with pre-drilled bolt holes).
Plenums are shipped first so installation with threaded rod (by others) can be completed before the ceiling is installed.
Diffuser mounting frame is shipped loose to be installed after the ceiling to allow for any ceiling irregularities.
The plenum flange is pre-notched to accommodate the quarter turn fasteners that are permanently affixed to the diffuser face panels.
All inlet connections are provided with flanges for ease of duct connection. Raw connections are also available if so specified.
EHD-295
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
E
E
P
P
P
P
ENGINEERED POLYMER
ENGINEERED POLYMER
PRODUCTS
PRODUCTS
Model EP5000
Pg. 300
For use in ceiling applications which call for a clean, smooth appearance, lightweight, corrosion
resistant, and ease of installation
For flush surface mount or inverted T-bar Lay-in ceiling grid systems
Surface Mount
EP5000-1
T-bar Lay-in
EP5000-6
Model EPCC5
Pg. 304
Surface Mount
EP-CC5-1
T-bar Lay-in
EP-CC5-6
Engineered Polymer Grilles & Registers - Louver Face Return/Exhaust - Series EPRH
Model EPRH
EPP
Pg. 308
EPP-298
3/2006
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
C
B
3/2006
1
2
5
1 16
13
8
Ceiling Opening D
1
2
C
B
9 x 9 Neck Size
5
1 16
1
24
13
8
1
2
A
5
1 16
13
8
Face View
Model
EP5000
12 x 12 Neck Size
Kit Contains 8 Baffles
Size 9 x 9, 12 x 12, 18 x 18 (Face View)
Ceiling Opening D
C
B
9 x 9 Neck Size
Kit Contains 4 Baffles
1
24
A
1
2
A 5
1 16
13
8
A
12 x 12 Neck Size
Kit Contains 8 Baffles
9 x 9 Neck Size
Kit Contains 4 Baffles
9 x 9 Neck Size
Kit Contains 4 Baffles
EPP
1
24
Blank off kits contain sufficient number of baffles to blank off entire neck area of diffuser. Only that number of baffles should actually be used to
either blank off sections to create 1, 2 or 3 way air patterns instead of standard 4-way pattern or reduce neck area around entire perimeter
(inner or outer ring) for reduced air flow.
12 x 12 Neck Size
Kit Contains 8 Baffles
*Actual neck opening is 6" x 6" (155 x 155) on 9" xA 9" (228 x 228) diffuser.
Models
5000-1
5000-6
Listed Size
12 x 12 Neck Size
Kit Contains 8 Baffles
Collar
Kit Contains
12 Baffles
18 x 18 Neck Size
Neck/Face
*9" x 9"/12" x 12" (228 x 228/300 x 300)
Inside (B)
8 7/8" x 8 7/8" (225 x 225)
Face (A)
20 11/16 (525)
20 11/16 (525)
11 7/8" x 11 7/8" (300 x 300) 12 1/8" x 12 1/8" (308 x 308) 17 9/16" x 17 9/16" (446 x 446)
17 3/4" x 17 3/4" (450 x 450)
8 7/8" x 8 7/8" (225 x 225)
Neck (C)
9 1/8" x 9 1/8" (231 x 231)
9 1/8" x 9 1/8" (231 x 231)
9 1/4 (235)
14 3/4 (375)
9 1/4 (235)
9 x 9 Neck Size
Kit Contains 4 Baffles
18 x 18 Neck Size
Kit Contains 12 Baffles
18 x 18 Neck Size
EPP-300
3/2006
1. Available Finishes
2. Available Accessories
Standard Finish:
01 White
3. Construction Details
3 (1.0)
7 (2.0)
3 (1.0)
8 (2.5)
5 (1.5)
12 (3.5)
7 (2.0)
15 (4.5)
10 (3.0)
12 (3.5)
572 (270)
19
668 (315)
8 (2.5)
10 (3.0)
7 (2.0)
5 (1.5)
16 (5.0)
7 (2.0)
20 (6.0)
21
26
31
34
644 (304) 858 (405) 1073 (504) 1288 (608) 1502 (709)
13 (4.0)
16 (5.0)
21 (6.5)
26 (8.0)
30 (9.0)
23
30
35
38
42
7 (2.0)
8 (2.5)
8 (2.5)
13 (4.0)
15 (4.5)
NC
CFM (Ls)
5 (1.5)
EPP
EPP-301
3/2006
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Optional Dampers
EPP
Engineered Polymer opposed blade dampers shall be provided. Damper shall be lever operated through the face of the diffuser.
EPP-302
3/2006
Available Neck
Air Pattern
Available Finishes
Available Options
9"
9"
Standard
Standard
EP-OBD5
12"
12"
S4-Sq - 4-Way
01 - White
18"
18"
Available Neck
Air Pattern
Available Finishes
24" x 24"
Standard
Standard
S4-Sq - 4-Way
01 - White
18"
18"
Available Options
EP-OBD5
Available Neck
EPP
Model
EPP-303
Damper Operator
16
(Screwdriver Slot)
16
Damper
15
32
1
12
5
1 16
3/2006
3
16
1
2
17
8
7
8
Listed Size - 1 41
EngineeredFace
Polymer
Cube Core Eggcrate Return/Exhaust Series EPCC5
View (Model EP-CC5-6)
1 3
16
1
2
3
16
23 21
15
32
23 21
Product Details
Attractive 1/2 x 1/2 grid by 1/2 deep design
22 15
16
22 3
4
23 21
Available for non-ducted applications
7
8
1
2
Damper Operator
(Screwdriver Slot)
15
22 16
5
2 16
Dimensions are in
1
2
Damper
Listed Size - 5
Model EPCC5
8Shown
22 3
4
inches78
3
16
3
16
1 16
16
2
Engineered Polymer
Cube Core Registers
- Eggcrate Return/Exhaust
Size - 1 1
4 Mount
Series EP-CC5 - 1/2" x 1/2" x 1/2"Listed
- Surface
Model EP-CC5D-1 - Damper
18
1
2
1 3
16
3
16
Damper Operator
(Screwdriver Slot)
1
Duct Size = Listed Size - 4
17
8
1 3
16
1
2
Damper Operator
(Screwdriver Slot)
27
8
3
16
1
2
5
1 16
Listed Size - 1 41
Damper
Damper
1
12
3
16
3
16
1
2
5
1 16
Listed Size - 1 41
Mounting Tab
22 15
16
Damper
Damper
22 3
4
7
8
1
2
3
28
3
16
EPP
3
16
Overall Size = 23 21
Damper Operator
(Screwdriver Slot)
1
2
7
8
15
22 16
22 3
4
Damper Operator
(Screwdriver Slot)
5
2 16
11
3 16
1
2
Listed Size - 1 1
4
5
1 16
Damper
Listed Size - 5
8
Damper
3
16
Listed Size - 5
8
5
2 16
Damper Operator
(Screwdriver Slot)
1 5
16
11
3 16
1
2
3
16
Duct SizeListed
= Listed
- 3
SizeSize
-1 1
4 8
Listed Size - 5
8
Damper
27
8
1
12
Damper Operator
(Screwdriver Slot)
1
3
Duct Size
2 = Listed Size - 8
5
Listed Size Listed Size - 18 41
1 5
16
3
16
Damper
27
8
1
12
1
2
1 5
16
3
16
Listed Size - 1 41
Mounting Tab
Damper
Damper
EPP-304
3
28
Damper
7
8
1
2
3
16
1
16
Countersunk
3/2006
Listed Size + 1 3
8
23 21
1 5
16
Listed Size - 1 1
4
3
8
15
32
23 21
3
16
Diameter Hole
Countersunk
1. Available Finishes
2. Available Accessories
Standard Finish:
01 White
3. Construction Details
Shipped Unattached
EP-OBD - Polymer Opposed Blade Damper (For Grille)
106
(50)
212
(100)
318
(150)
424
(200)
530
(250)
636
(300)
848
(400)
1060
(500)
17
8
6" x 6"
8" x 8"
10" x 10"
12" x 6"
12" x 12" 23" x 23"
(150 x 150) (200 x 200) (250 x 250) (300 x 150) (300 x 300) (584 x 584)
Ps Inches (Pa) 0.008 (2)
0.004 (1)
NC
Ps Inches (Pa)
NC
Ps Inches (Pa)
Ps Inches (Pa)
0.004 (1)
0.008 (2)
28
18
NC
0.036 (9)
0.016 (4)
0.060 (15)
0.032 (8)
0.016 (4)
0.088 (22)
0.173 (43)
35
42
25
42
30
0.120 (30)
17
8
1
2
NC
Ps Inches (Pa)
0.060 (15)
0.241 (60)
NC
Ps Inches (Pa)
0.008 (2)
18
0.060 (15)
1 3
16
0.028 (7)
28
0.161 (40)
36
Ps Inches (Pa)
1
2
3
16
23 21
0.008 (2)
NC
Ps Inches (Pa)
NC
Ps Inches (Pa)
0.032 (8)
0.125 (32)
NC
15
32
1 3
16
3
16
0.241 (60)
43
NC
23
0.108 (27)
33
0.028 (7)
.002 (.5)
0.044 (11)
.004 (1)
15
.006 (1.5)
0.108 (27)
0.10 (2.5)
27
35
0.160 (40)
22 3
4
22
0.052 (13)
41
22 15
16
37
0.241 (62)
52
(25)
7
8
1
2
3
16
.016 (4)
-
Damper Operator
(Screwdriver Slot)
Damper
EPP
Flow Rate
CFM (Ls)
23 21
27
8
1
12
1
2
5
1 16
3
16
Listed Size - 1 41
22 15
16
22 3
4
7
8
1
2
3
16
Damper Operator
(Screwdriver Slot)
Damper
Listed Size - 5
8
2
Damper Operator
(Screwdriver Slot)
5
11
3 16
16
For more product information visit us at www.metalaire.com
Damper
5
1 16
1
2
Listed Size - 1 1
3
16
EPP-305
3/2006
EPP
Units shall be designed to integrate into the specified ceiling system or wall mounting application.
Optional Dampers
Engineered Polymer opposed blade dampers shall be provided. Damper shall be lever operated through the face of the diffuser.
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
EPP-306
3/2006
Available Neck
Available Finishes
6"
6"
Standard
8"
8"
01 - White
12"
12"
12"
6"
12"
12"
22"
22"
Available Options
EP-OBD
22"
22"
Module
Available Finishes
24" x 24"
Standard
Available Options
EP-OBD
01 - White
Available Neck
EPP
Model
EPP-307
3/2006
17
8
11
16
3
3
1 3
4
16
Louver
Face
Return/Exhaust
Series EPRH
16
Product Details
Fixed 45 angled
deflecting
blades provide a
Face View
(All models)
3
Listed
Size
+
1
vision obscured appearance
4
1
1
Duct Size = Listed Size - 4
17
8
11
16
Listed Size - 1 4
5
1 16
3
4
1 3
16
3
16
3
8
1 Diameter Hole
4 Countersunk
1
Duct Size = Listed Size - 4
Listed Size - 5
8
(Screwdriver Slot)
3
4
1
Duct Size = Listed Size - 4
17
8
11
16
1 3
16
Damper Operator
(Screwdriver Slot)
1
12
27
8
3
16
3
4
3
16
5
1 16
Damper
3
4
Listed Size + 1 34
Listed Size - 1 41
1
Duct Size = Listed Size - 4
Damper Operator
(Screwdriver Slot)
Listed Size - 5
8
5
2 16
Damper
3
8
3
16
5
1 16
1 Diameter Hole
4 Countersunk
3
4
Damper Operator
(Screwdriver Slot)
1
Duct Size = Listed Size - 4
Listed Size - 5
8
1. Available Finishes
5
1 16
1
Duct Size = Listed Size - 4
Damper
2. Available Accessories
3. Construction DetailsDamper
Listed Size - 5
8
Damper Operator
(Screwdriver Slot)
1
12
27
EP-OBD
- Polymer Opposed Blade Damper (For Grille)
8
5
2 16
3
16
Standard Finish:
01 White
EPP
5
1 16
3
4
5
1 16
3
4
1
Duct Size = Listed Size - 4
17
8
11
16
1 3
16
3
4
1
Duct Size = Listed Size - 4
Damper Operator
(Screwdriver Slot)
EPP-308
5
2 16
Listed Size - 5
8
Damper
3
16
3/2006
212
(100)
318
(150)
424
(200)
530
(250)
636
(300)
6" x 6"
8" x 8"
10" x 10"
12" x 6"
12" x 12"
(150 x 150) (200 x 200) (250 x 250) (300 x 150) (300 x 300)
Ps Inches (Pa) 0.028 (7)
0.008 (2)
*
0.004 (1)
NC
Ps Inches (Pa)
20
0.040 (10)
0.140 (35)
-
NC
Ps Inches (Pa)
NC
0.016 (4)
0.024 (6)
0.060 (15)
0.108 (27)
0.028 (7)
0.120 (30)
0.221 (55)
0.060 (15)
25
42
27
34
19
0.060 (15) 0.402 (100) 0.100 (25)
Ps Inches (Pa)
NC
Ps Inches (Pa)
27
0.153 (38)
32
0.201 (50)
NC
36
EPP
EPP-309
3/2006
Performance Specification
The manufacturer shall provide published performance data. Data shall be tested in accordance to ANSI/ASHRAE Standard 70-1991.
Optional Dampers
EPP
Engineered Polymer opposed blade dampers shall be provided. Damper shall be lever operated through the face of the diffuser.
EPP-310
3/2006
6"
6"
Standard
8"
8"
01 - White
10"
10"
12"
6"
12"
12"
Available Options
EP-OBD
EP-RH-1
Available Neck
EPP
Model
EPP-311
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
8/2/04
Interoperability
All MDC diffusers are native BACnet devices and communicate using
MS/TP protocol. These devices can communicate to any BACnet system
regardless of system manufacturer giving building owners and operators
the freedom to select and change building controls even after the system
is installed. Using the METALAIRE Portal, the MDC diffusers can be setup to communicate with Modbus or Johnson Controls N2 protocol.
With the addition of a Serial LonTalk Adapter, the MDC can be integrated
into a Lon system.
This diffuser is also an excellent choice for large open office areas. By
using a master unit along with 3 slave diffusers, the MDC can cut large
work spaces into small occupant zones maximizes comfort and
increasing productivity.
Ease of Installation
Flexibility
Expandability
The MDC has the power and expandability to operate stand-alone or
communicate on a wide area network. As a native BACnet device, the
MDC can start as a stand-alone unit to control the temperature in a
single zone. By adding a communication link, the expansion of the
system is unlimited.
The MDC is easy to configure using the HHC hand held control. The
HHC uploads all the operation functions for the MDC operation. Built
into each controller are LEDs designed to make trouble shooting easy.
Installers and building operators from the floor can the LEDs indicating
normal operation, transferring firmware, auto-detecting baud rate,
hardware failure, manual mode, and firmware error. Indicators also show
TX transmit and RX receive displays.
MDC
MDC Features
MDC-315
Flexibility
The MDC has the flexibility to operate in applications ranging
from office buildings, retail stores, schools, hospitals, and
conference centers. Flexibility built into the MDC allows the
diffuser to be applied to a wide range of applications providing
superior control and occupant comfort
Interoperability
All MDC diffusers are native BACnet devices and communicate
using MS/TP protocol. These devices can communicate to any
BACnet system regardless of system manufacturer giving building
owners and operators the freedom to select and change building
controls even after the system is installed. Using the METALAIRE
Portal, the MDC diffusers can be set-up to communicate with
Modbus or Johnson Controls N2 protocol. With the addition of a
Serial LonTalk adapter, the MDC can be integrated into a Lon
system
Ease of Installation
Installation of the MDC is quick and easy. In the basic
MDC
MDC-316
3/2006
3/2006
Earthquick Tab
Latch Tabs
1 1/4
2 1/2
Ceiling
Line
Earthquick Tab
Latch Tabs
Neck -1/8
Neck -1/8
Earthquick Tab
Latch Tabs
1 1/4
1 1/4
T-Bar by Others
2 1/2
Ceiling
Line
2 1/2
1/8
1. Available Finishes
Standard Finish:
01 WhiteEarthquick Tab
1/8
2. Available Accessories
Latch Tabs
1 1/4
T-Bar by Others
4. Construction Details
3. Available Options
2 1/2
90
115
140
160
0.013 0.021 0.032 0.041
0.313 0.321 0.332 0.341
23
25
26
27
3-4-6 3-4-7 3-4-8 3-5-8
Inlet
Static
Pressure
0.2
6"
Inlet
Static
Pressure
0.3
Inlet
Static
Pressure
0.4
Inlet
Static
Pressure
0.5
Inlet
Static
Pressure
0.1
8"
Inlet
Static
Pressure
0.2
Inlet
Static
Pressure
0.4
Inlet
Static
Pressure
0.3
Inlet
Static
Pressure
0.5
60
95
0.015
0.115
17
2-2-5
70
105
0.018
0.118
18
2-3-5
185
0.055
0.355
28
3-5-9
205
0.068
0.368
29
3-5-9
165
0.044
0.244
24
3-4-8
80
115
0.021
0.121
18
2-3-5
180
0.052
0.252
24
3-4-8
90
125
0.025
0.125
19
2-3-5
190
0.058
0.258
24
3-4-8
100
135
0.029
0.129
19
2-3-5
80
100
120
135
0.010 0.016 0.023 0.029
0.210 0.216 0.223 0.229
20
21
22
22
2-4-6 2-4-6 3-4-7 3-4-7
150
0.036
0.236
23
3-4-8
205
0.068
0.268
25
3-4-8
105
140
165
195
0.018 0.032 0.044 0.061
0.418 0.432 0.444 0.461
25
27
29
31
3-5-7 3-5-8 4-5-8 4-6-9
215
240
265
285
305
0.075 0.093 0.114 0.131 0.150
0.475 0.493 0.514 0.531 0.550
32
33
34
35
36
4-6-9 4-6-10 4-6-10 4-6-11 4-6-11
220
240
255
0.078 0.093 0.105
0.378 0.393 0.405
29
30
30
3-5-9 3-5-10 3-5-10
120
155
190
220
245
275
300
320
345
0.023 0.039 0.058 0.078 0.097 0.122 0.146 0.166 0.192
0.523 0.539 0.558 0.578 0.597 0.622 0.646 0.666 0.692
30
32
34
35
36
37
37
38
38
4-5-7 4-6-8 4-6-9 4-6-9 4-6-10 4-7-11 5-7-11 5-7-11 5-7-12
20
30
40
50
65
85
0.001 0.002 0.004
0.101 0.102 0.104
16
16
17
1-2-4 1-2-4 2-2-5
50
100
0.005
0.105
17
2-2-5
130
160
0.009 0.013
0.309 0.313
30
31
3-4-7 3-4-8
190
0.018
0.318
31
3-5-9
80
110
135
0.003 0.006 0.009
0.203 0.206 0.209
25
26
26
2-3-6 2-4-7 2-4-7
95
0.005
0.305
29
2-4-6
155
0.012
0.212
27
3-4-8
60
115
0007
0.107
18
2-3-5
180
0.017
0.217
27
3-4-8
70
130
0.009
0.109
18
2-3-5
200
0.020
0.220
27
3-4-8
80
145
0.011
0.111
19
2-3-6
220
0.025
0.225
28
3-4-9
90
160
0.013
0.113
20
2-3-6
235
0.028
0.228
28
3-4-9
100
170
0.015
0.115
20
2-3-6
255
0.033
0.233
28
3-4-9
220
245
270
295
320
0.025 0.031 0.037 0.045 0.052
0.325 0.331 0.337 0.345 0.352
32
32
33
33
33
3-5-9 3-5-10 4-5-10 4-5-11 4-6-11
20
30
40
50
45
60
75
85
0.003 0.006 0.009 0.012
0.103 0.106 0.109 0.112
<15
<15
16
16
1-2-4 1-2-4 2-2-5 2-2-5
MDC
120
160
195
230
265
295
325
355
385
0.007 0.013 0.019 0.027 0.036 0.045 0.054 0.064 0.076
0.407 0.413 0.419 0.427 0.436 0.445 0.454 0.464 0.476
32
33
34
35
36
37
38
38
39
3-5-7 3-5-8 4-5-9 4-6-10 4-6-10 4-6-11 4-6-11 4-7-12 4-7-12
125
175
220
260
300
335
370
405
440
0.008 0.016 0.025 0.035 0.046 0.057 0.070 0.084 0.099
0.508 0.516 0.525 0.535 0.546 0.557 0.570 0.584 0.599
35
36
38
38
39
39
40
40
40
3-5-7 4-6-8 4-6-9 4-6-10 5-7-11 5-7-12 5-7-12 5-7-13 5-8-13
MDC-317
20
50
0.001
0.101
17
1-2-4
30
75
0.001
0.101
18
1-2-4
105
0.002
0.302
35
2-4-7
145
0.004
0.304
35
3-4-8
135
0.004
0.504
41
3-5-7
Inlet
Static
Pressure
0.1
10"
Inlet
Static
Pressure
0.2
Inlet
Static
Pressure
0.4
Inlet
Static
Pressure
0.3
Inlet
Static
Pressure
0.5
Inlet
Static
Pressure
0.1
Inlet
Static
Pressure
0.2
12"
Inlet
Static
Pressure
0.3
Inlet
Static
Pressure
0.4
Inlet
Static
Pressure
0.5
Inlet
Static
Pressure
0.2
MDC
Inlet
Static
Pressure
0.3
14"
Inlet
Static
Pressure
0.4
Inlet
Static
Pressure
0.5
MDC-318
130
0.004
0.404
39
3-5-7
20
50
0.000
0.100
19
1-2-3
75
0.001
0.201
29
2-2-5
115
0.001
0.401
38
2-4-7
50
120
0.003
0.103
19
2-3-5
60
140
0.004
0.104
20
2-3-6
70
160
0.005
0.105
21
2-3-6
190
0.008
0.308
36
3-5-9
225
0.011
0.311
36
3-5-10
265
0.015
0.315
36
4-5-10
305
0.019
0.319
36
4-6-11
195
205
305
0.008 0.013 0.019
0.508 0.513 0.519
41
41
42
4-6-9 4-6-10 5-7-11
360
0.027
5.27
42
5-7-12
115
0.003
0.203
30
2-3-7
145
0.004
0.204
30
2-4-7
180
0.007
0.207
31
3-4-8
185
235
280
0.007 0.012 0.016
0.407 0.412 0.416
40
40
41
4-5-9 4-6-10 4-6-11
210
0.009
0.209
31
3-4-9
325
0.022
0.422
41
4-7-11
90
200
0.008
0.108
22
2-3-7
245
0.013
0.213
31
3-5-9
275
0.016
0.216
31
3-5-10
305
0.019
0.219
32
3-5-10
370
0.029
0.429
41
5-7-12
415
0.036
0.436
42
5-7-13
460
0.044
0.444
42
5-8-14
410
0.035
0.535
42
5-8-13
460
0.044
0.544
42
5-8-14
375
0.029
0.329
37
4-6-12
410
0.035
0.335
37
4-7-13
510
0.055
0.555
43
6-9-14
560
0.066
0.566
43
6-9-15
145
0.002
0.302
36
3-4-8
190
0.004
0.304
36
3-4-9
235
280
330
375
420
465
0.006 0.008 0.011 0.014 0.018 0.022
0.306 0.308 0.311 0.314 0.318 0.322
37
37
37
38
38
38
3-5-10 3-5-10 4-6-11 4-6-12 4-6-13 4-7-13
125
0.002
0.502
41
3-4-7
190
0.004
0.504
42
3-5-9
75
0.000
0.200
29
1-2-4
20
50
0.000
0.100
21
1-1-3
260
0.007
0.207
32
3-4-9
295
0.009
0.209
32
3-5-9
100
240
0.006
0.106
25
2-3-7
330
370
0.011 0.014
0.211 0.214
32
33
3-5-10 4-5-11
170
0.003
0.403
39
3-4-8
225
280
335
390
440
495
550
0.005 0.008 0.011 0.015 0.020 0.025 0.031
0.405 0.408 0.411 0.415 0.420 0.425 0.431
40
41
41
42
42
43
43
3-5-10 4-6-11 4-6-12 4-7-13 5-7-13 5-7-14 5-8-15
30
75
0.000
0.100
22
1-2-4
40
105
0.001
0.101
23
1-2-4
50
130
0.001
0.101
24
2-2-5
60
160
0.001
0.101
25
2-3-5
190
0.002
0.302
37
3-4-8
240
0.003
0.303
38
3-4-9
290
345
395
445
500
0.005 0.006 0.009 0.011 0.014
0.305 0.306 0.309 0.311 0.314
38
38
39
39
39
3-5-10 4-5-11 4-6-12 4-6-12 4-7-13
115
0.001
0.201
30
2-3-6
90
0.000
0.300
36
2-3-5
140
0.001
0.301
37
2-3-7
125
0.001
0.501
42
2-4-7
190
0.002
0.502
42
3-5-9
105
0.001
0.401
38
2-3-6
220
0.005
0.205
31
3-4-8
90
220
0.005
0.105
24
2-3-7
500
0.052
0.452
42
5-8-14
95
0.001
0.301
35
2-3-6
185
0.003
0.203
31
2-4-7
80
195
0.004
0.104
23
2-3-6
335
0.024
0.224
32
4-5-11
50
125
0.002
0.102
21
2-3-5
2-3-6
0.002
0.202
30
2-3-7
70
170
0.003
0.103
23
2-3-6
340
0.024
0.324
36
4-6-12
100
220
0.010
0.110
22
2-3-7
40
100
0.001
0.101
20
2-2-5
110
0.001
0.201
29
2-3-6
60
150
0.002
0.102
22
2-3-6
80
180
0.007
0.107
21
2-3-6
30
75
0.001
0.101
20
1-2-4
Inlet
Static
Pressure
0.1
80
0.001
0.201
30
2-3-6
40
95
0.002
0.102
19
2-2-5
165
0.001
0.401
39
3-4-8
255
315
380
440
505
565
630
0.007 0.010 0.015 0.020 0.026 0.032 0.040
0.507 0.510 0.515 0.520 0.526 0.532 0.540
42
43
43
43
44
44
44
4-6-10 4-6-11 5-7-12 5-8-13 5-8-14 6-9-15 6-9-16
155
0.001
0.201
31
2-3-6
225
0.003
0.403
40
3-5-9
195
0.002
0.202
31
2-4-7
235
0.003
0.203
32
3-4-7
70
190
0.002
0.102
25
2-3-6
275
0.004
0.204
33
3-4-9
80
220
0.003
0.103
26
2-3-7
315
0.005
0.205
33
3-5-9
90
250
0.003
0.103
27
2-3-7
100
280
0.004
0.104
27
2-4-7
355
400
0.007 0.009
0.207 0.209
34
34
3-5-10 4-5-11
285
345
405
465
530
590
0.004 0.006 0.009 0.012 0.015 0.019
0.404 0.406 0.409 0.412 0.415 0.419
40
41
42
42
43
43
4-5-11 4-6-12 4-6-13 5-7-14 5-7-15 5-8-15
255
325
390
460
530
600
670
0.004 0.006 0.008 0.012 0.015 0.020 0.024
0.504 0.506 0.508 0.512 0.515 0.520 0.524
43
44
44
45
45
46
46
4-5-10 4-6-11 4-7-13 5-7-14 5-8-15 6-8-16 6-9-16
3/2006
3/2006
1)
The MDC measure both the supply and room air temperature. The DDC
controller reacts to meet the requested room set point by either increasing
or decreasing the volume of air through the diffuser. The MDC can be set
for both maximum and minimum flow.
2)
3)
4)
2)
3)
The MDC can control electric duct heat installed up stream from the
diffuser.
1)
2)
Since the duct heater raises the supply temp the Cool to Heat
mode can only be changed while the duct heater is OFF, or if the
supply air temp exceeds 110 F while it is ON which indicates
warm air being supplied to the heater.
1)
2)
3)
If the heating set point is raised, if the difference between the HEAT and
COOL is less than 2F, the cooling set point will automatically be raised
until the 2F separation is reached. Lowering the HEAT set point never
affects the COOL set point.
1)
Set the MDC damper with the handheld to one of the manual
modes, such as Cool Maximum. The damper position in percent
open may be monitored with the handheld while the damper is in
manual mode.
2)
3)
4)
Measure and adjust airflow again with the flow hood until within
5 10% of desired setting in CFM.
5)
Repeat this for all 4 cool and heat minimum and maximum
set points.
Units of Measure
The MDC can be setup to show either degrees C or F
All set points (Analog Values - AVS) and Binary Value (BVS) F or C are
stored in EEPROM. The set points are limited to the following ranges:
Description
Range
CSP = 76F
HSP = 70F
MDC
MDC-319
3/2006
The MDC has the power to call up preprogrammed commands as well as the ability
to adjust a number of set points maximizing
the flexibility of the diffuser. Using either
the HHC hand held controller or by
plugging into the communications port on
the MDC, the following Set Points can be
adjusted:
When adjusting the temperature offset on the METALAIRE T-Stat, the cool
and heat set points in on the MDC are NOT adjusted. The temperature set
points are maintained at the METALAIRE T-Stat. An offset is added or
subtracted to whichever cool or heat is in use at that time. These set points
when set are limited to within the range of 68F to 80F.
Set Points
The Occupied and F or C parameters have 3 sources of data. They are the
METALAIRE T-Stat, or the MDC handheld and BACnet. BACnet temperature
parameters are always in Fahrenheit. The Cool Set point and Heat Set point
have 2 sources of data, which are the MDC handheld and BACnet. The 2
sources of data for Room Temp are the METALAIRE T-Stat or the MDC
thermistor on the PCB. This data is updated on a first come, first serve
basis with only one BACnet object type for each. The last to change data is
the present value.
The METALAIRE T-Stat and MDC will share the following BACnet objects.
Parameter
Logistat Basic/Plus/Pro
MDC260
BACnet Object
Room Temp.
Room Temp
(AN_2 read only)
ZT_AIS
+/- (0 3)F
Temp Offset
Analog Value #1
(writable)
MDC_AVS
+/- (0 3)F
Temp Offset
Analog Value #4
(writable)
MDC_AVS
Occupied
Device Variable
(read only)
BVS
F or C
AI #16
(Eikon metric global)
Binary Value #1
(writable)
BVS
BACnet Address
Cooling set point
Cool min damper position
Cool max damper position
Heating set point
Heat min damper position
Heat max damper position
Temp Units F or C (Local)
Room occupied/unoccupied
Commands
The MDC has a number of pre-programmed Commands. These commands
can be executed either by use of the HHC Hand Held Controller or by
plugging into the communication port on the MDC.
The available commands include:
Move damper to minimum cool position
Move damper to maximum cool position
Move damper to minimum heat position
Move damper to maximum heat position
Read room temperature
Read source temperature
Read damper position
Read air flow
Data Manipulation Keys:
These data manipulation keys make changing set points and passwords
easier. The up and down arrow keys increase or decrease the data by a
pre-set amount regardless of cursor position. The cursor on the HHC is
not moved by the UP/DOWN arrow keys.
Number Keys (0-9)
Data is entered with the number keys from left to right starting with the
most significant digit. The number keys may work in combination with the
up and down arrow keys.
Command Keys:
MDC
MDC-320
1.
Accept (Enter) Keys: When pressed after data has been changed
and is valid, the modified data will be stored in eeprom as the
present value.
2.
Cancel Key : Aborts present edit session, but does not change
modes. Displays original data in eeprom.
3.
Display Keys : These display keys are only pressed once to display
the result. The room temperature, supply temperature, damper
position and flow are updated once every 4 seconds.
3/2006
5.
Command Keys:
1.
Accept (Enter) Keys: When pressed after data has been changed
and is valid, the modified data will be stored in eeprom as the
present value.
2.
Cancel Key: Aborts present edit session, but does not change
modes. Displays original data in eeprom.
3.
Display Keys: These display keys are only pressed once to display
the result. The room temperature, supply temperature, damper
position and flow are updated once every 4 seconds.
4.
5.
6.
May be set in user mode only. The range is 68F - 78F (20C - 25.5C).
Rolls over to 68 when 78 is incremented and back to 68 if decremented.
The default heat setpoint (HSP) is 70 F.
Key press order: HeatSetPnt, UP/DN, Accept/Cancel
Mode Key
The mode key sets key functions for User and Install mode. Install mode
will exit when the mode key is pressed again or after 15 minutes. The
range for the password is 0 to 9999. When 2-New Password is selected,
the old password must be entered first in order to set the new one. When
in edit mode, there is nothing displayed on the data line except an = at the
beginning of the line. The default password is 2345.
Key press order: Mode, 1/2, UP/DN, Accept/Cancel
The MDC diffusers can communicate through either the HHC Hand Held
Controller or through
the network
communication port.
COOLMIN KEY
Sets the cool
minimum damper
position. A percent open is entered within the range of 0% to 30% in 1%
increments. When 30% is reached, the number rolls over to 0% and back
to 30% if decremented. The default cool min (CMIN) is 5% (t_unit = 73C).
6.
HEATMAX KEY
Sets the heat maximum damper
position. A percent flow is
entered within the range of
60% to 100% in 1%
increments. When 100% is
reached, the number rolls over
to 60% and back to 100% if
decremented. The default heat
max (HMAX) is 100%( t_unit =
52C).
COOLMAX KEY
Sets the cool maximum damper position. A percent open is entered within
the range of 60% to 100% in 1% increments. When 100% is reached, the
number rolls over to 60% and back to 100% if decremented.The default
cool max (CMAX) is 100%(t_unit = 52C).
Key press order: CoolMax, UP/DN, Accept/Cancel
HEATMIN KEY
Sets the heat minimum damper position. A percent open is entered within
the range of 0% to 30% in 1% increments. When 30% is reached, the
number rolls over to 0% and back to 30% if decremented. The default heat
Mode Key
The mode key sets key functions for User and Install mode. Install mode
will exit when the mode key is pressed again or after 15 minutes. The
range for the password is 0 to 9999. When 2-New Password is selected,
the old password must be entered first in order to set the new one. When
in edit mode, there is nothing displayed on the data line except an = at the
beginning of the line.
The default password is 2345.
Key press order: Mode, 1/2, UP/DN, Accept/Cancel
MDC
The MDC diffusers can communicate through either the HHC Hand Held
Controller or through the network communication port.
MDC-321
For more product information visit us at www.metalaire.com
3/2006
HEATER_TYPE KEY
Sets the Auxiliary Heater Type to the enumerated value of remote(0) or
duct(1). The default Aux. Heater Type is remote.
Key press order:
HeaterType
DUCT_HTR_OT KEY
Sets the Duct Heater Over Temp power off (only applies to duct heaters).
A temperature is entered within the range of 90F to 120F in 1
increments. When 120F is reached, the number rolls over to 90F and
back to 120F if decremented.
The default Duct Heater Overtemp is 110F.
Key press order:
HEATMIN KEY
Sets the heat minimum damper position. A percent open is entered within
the range of 0% to 30% in 1% increments. When 30% is reached, the
number rolls over to 0% and back to 30% if decremented. The default heat
min (HMIN) is 5% (t_unit = 73C).
Key press order:
HEATMAX KEY
Sets the heat maximum damper position. A percent flow is entered within
the range of 60% to 100% in 1% increments. When 100% is reached, the
number rolls over to 60% and back to 100% if decremented.
The default heat max (HMAX) is 100%( t_unit = 52C).
MDC
ADDRESS KEY
Sets the BACnet MS/TP address for the MDC260. The acceptable range is 1
- 254. When 255 is reached, the number rolls over to 0 and back to 255 if
decremented. The default address is 0 or 255 which ever prevents
participation on the network.
Key press order:
MDC control
Full open(2)
Cool Max(3)
Heat Max(4)
Cool Min(5)
Heat Min(6)
Mode
Numbers 0-9
Up Arrow
Accept
Down Arrow
Cancel
User mode
3
5
CoolSetPnt
HeatSetPnt
CoolMin
HeatMin
10
CoolMax
11
HeatMax
12
Address
13
Auto/Manual
16
DamperPos
17
SourceTemp
18
RoomTemp
19
Flow
20
Occupied
HeaterType
21
F/C
DuctHtrOT
MDC-322
Install mode
3/2006
Instance
Description
Device
Variable
File
Analog Input
Analog Input
Damper Position
(AN_4 - LM35DM)
UNITS= PERCENT
RANGE=0..100
PROPTYPE_FLT_12_4
PA_RO, PA_S
Analog Input
15
PROPTYPE_FLT_12_4
PA_RO, PA_S
Analog Input
16
Zone Temp
(AN_0 or AN_2 - thermistor)
UNITS= F only
PROPTYPE_TEMP_REAL
PA_RO, PA_S
Analog Input
17
PROPTYPE_FLT_12_4
PA_WR, PA_S
Analog
Value
Analog
Value
PROPTYPE_TEMP_REAL
PA_WR, PA_N
Analog
Value
PROPTYPE_FLT_12_4
PA_WR, PA_N
Analog
Value
PROPTYPE_FLT_12_4
PA_WR, PA_N
Analog
Value
PROPTYPE_FLT_12_4
PA_WR, PA_N
Analog
Value
PROPTYPE_FLT_12_4
PA_WR, PA_N
Analog
Value
PROPTYPE_TEMP_REAL
PA_WR, PA_N
Analog
Value
16
PROPTYPE_U16_REAL
PA_WR, PA_S
Multi-State
Value
Damper Control
Enumerated (auto(1), full open(2),
PROPTYPE_U8_CMND
cool max(3), heat max(4), cool min(5), PA_WR, PA_N
heat min(6), full close(7) )
Binary Value
Units = F or C
Enumerated
(Off = F, On = C)
Units = F or C
PROPTYPE_ENUM_8
PA_WR, PA_N
Binary Value
Heater Type
Enumerated
(Off = Remote, On = Duct)
PROPTYPE_ENUM_8
PA_WR, PA_N
Binary Value
16
Occupied/Unoccupied
Enumerated
(Off = UnOcc., On = Occ.)
PROPTYPE_ENUM_8
PA_RO, PA_S
PROPTYPE_TEMP_REAL
PA_RO, PA_S
MDC
PROPTYPE_TEMP_REAL
PA_WR, PA_N
MDC-323
MDC
Master/Slave Units
Master MDC Can Control Up to 3 Slaves
24 Volts
Master
Slave
Slave
MDC
Slave
MDC-324
3/2006
3/2006
MDC
MDC-325
MDC
MDC-326
3/2006
3/2006
MDC
MDC-327
3/2006
CONNECTORS
AMP MTA-100 22 AWG receptacle part number 640440-x, where x is the
number of terminals
CRIMPING TOOL :
SPECIFICATIONS
POWER
THERMISTORS :
OUTPUTS
Mount the MDC using 4" snaptrack on the lower plate of the diffuser near
the edge with the infrared (IR) components facing down. Mounting the
MDC near the edge is required to use the handheld remote and view status
LEDs.
(1) The +/-10% specification does not apply to the hot wax actuator, which
is very sensitive to low voltage conditions.
(2) This includes additional power for an array type flow sensor. The
existing module is 12 VA.
Flow Sensor
Alpha Mini-Series, 62A2251-C3
2252 ohms @ 25 C, 28AWG, 2 inch leads
FLOW SENSOR WIRING
Use a 13" long 22AWG stranded, 4 conductor cable to connect the flow
and source air temperature thermistors to the MDC as shown in setup
diagram (page 21 ).
NOTE: The source air and flow thermistors look almost identical. Make
sure the 2252 ohm thermistor is connected to the FLWA and FLWB
terminals.
POWER WIRING/TRANSFORMER SIZING
The most important power consideration is providing adequate voltage to
the hot wax actuators. The MDC is designed for a +/-10% voltage range,
but the hot wax actuator does not work well at lower voltage. The power
dissipation of the hot wax actuator and the resulting heating time varies
drastically with supply voltage, as the table 1 shows.
INPUT RESOLUTION
10 bit.
COMMUNICATION
9600 bps or 38.4 kbps, automatically detected
(determined by MDC gateway module).
22.5
83 ?
27
8.3
STATUS INDICATION
Visual (LED) indicators.
PROTECTION
MDC
MOUNTING
MDC-328
3/2006
Meaning
Meaning
Manual Mode
transferring firmware
Firmware error
Transfer memory to the
module to correct
COMMUNICATION LEDs
TX
RX
ADDRESSING
The MDC stores the BACnet MS/TP address in non-volatile memory
(EEPROM). The handheld remote must be used to set the address. To set
the address, enter installer mode and use the address button using the
following key sequences:
Mode Key
1
enter password up to 4 digits
(for production default is 2345,
for beta modules default is 1)
Accept
Enter address
Accept button
Note:
The password can be changed by selecting option 2 instead of option 1.
HANDHELD REMOTE
MDC
When using the remote, point it upward toward the MDCs infrared (IR)
sensors near the edge of the diffuser. For reliable communications
between the remote and MDC, the remote must be pointed used within a
cone of approximately 15 - 20 from vertical below MDCs IR sensor.
Address button
MDC-329
With the choice of our Pre-Flite Catalog, Quick Select Catalog, InfoSource Catalog,
InfoSource CD and our web site, www.metalaire.com, you pick the format for
product information that best suits your air distribution design needs.
The METALAIRE Quick Select Catalog is designed to save you time selecting air distribution
equipment. This catalog is a compact version of our InfoSource Catalogs and includes
drawings and performance for our most popular products. The Quick Select Catalog is
broken into product types with each section beginning with a model summary that includes
features and benefits of our products. To obtain product information not included in the
Quick Select Catalog, simply go to our web site at www.metalaire.com.
The METALAIRE InfoSource Catalog suite is the leading product catalog in the industry.
Included in these catalogs are the complete product listings, drawings, product features and
benefits, product performance data, specifications, and model specifications. These catalogs
are organized to make it quick and easy to find the information you are looking for.
InfoSource Catalog Suite
Ceiling Diffusers Catalog
Air Terminal Unit Catalog
Our InfoSource CD has set the standard in the industry for air distribution product selection.
This CD contains a complete library of all our catalogs and submittals along with our air
terminal unit selection program.
METALAIRE leads the industry with a web site that contains all the product literature
and performance data needed to design your air distribution system. Our web site
includes all our submittals, catalogs, installation manuals, as well as as other valuable
information to aid you in air distribution design.
U
U
F
F
D
D
Underfloor
Underfloor
Diffuser
Diffuser
3/2006
UFD
Underfloor Diffuser
1. Available Finishes
Standard Finish:
WFO diffusers are available in a state grey finish
(RAL 7037 Mid Grey) as standard. Other colors
can be specified subject to a minimum quantity.
EPP-332
2. Advantages
Ability to change between horizontal and
vertical settings instantly
Commissioning settings are retained once set
using the momory locating peg
Reduced installation time with easy fit
locking collar
Quick fit plenum
A
A
C
C
C
C
ACCESSORIES
ACCESSORIES
3/2006
Specified
Duct Size
-1
8
See Detail A
21
32
.160
Detail A
360 Rotaion
1
14
.650
1
Specified Duct Size - 8
1
2
1
2
1
Listed Size
3
+
8
3
4
Nominal Size - 3
4
1
2
Blade
1
1
2
Specified
Duct Size
1
-8
Damper Operator
(Screwdriver Slot)
ACC-334
3/2006
Vertical Outside
Vertical Inside
Opposed Blade Damper Aluminum Sizes 14 for Series 900 Model 900D
ACC-335
ACC-336
3/2006
3/2006
ensuring
ACC-337
ACC-338
3/2006
index
Series
Section
D5 . . . . . . . . . . . .ACC-337
D7 . . . . . . . . . . . .ACC-337
3000 . . . . . . . . . . .RCD-14
EP5000 . . . . . . . . .EPP-300
3100 . . . . . . . . . . .RCD-18
EPCC5 . . . . . . . . . .EPP-304
3200 . . . . . . . . . . .RCD-22
EPRH . . . . . . . . . .EPP-308
5000 . . . . . . . . . . .DCD-34
G3 . . . . . . . . . . . .ACC-337
5200 . . . . . . . . . . .DCD-58
GD3 . . . . . . . . . . .ACC-337
5500 . . . . . . . . . . .DCD-46
HPL-CL . . . . . . . . .EHD-260
HPL-HA . . . . . . . . .EHD-266
5500DD . . . . . . . . .ARP-242
HPL-PR . . . . . . . . .EHD-272
5500S . . . . . . . . . .DCD-48
HRD-CL . . . . . . . . .EHD-278
5700 . . . . . . . . . . .DCD-62
HRD-HA . . . . . . . .EHD-284
5750 . . . . . . . . . . .DCD-68
L-5000 . . . . . . . . .LSD-200
5800 . . . . . . . . . . .DCD-74
L9 . . . . . . . . . . . . .ACC-334
6600 . . . . . . . . . . .LSD-166
LT . . . . . . . . . . . . .PSD-230
6600SP . . . . . . . . .LSD-184
6600SQ . . . . . . . . .ARP-248
MDC . . . . . . . . . .MDC-316
7000 . . . . . . . . . . .PCD-104
OBD . . . . . . . . . . .ACC-334
7300 . . . . . . . . . . .PCD-114
OBDA . . . . . . . . . .ACC-334
7350 . . . . . . . . . . .PCD-116
PERIFLOW . . . . . . .EHD-290
7500 . . . . . . . . . . .PCD-118
PHC . . . . . . . . . . .PSD-224
7550R-F . . . . . . . .PCD-160
PHENOMENATOR . .DCD-80
7600 . . . . . . . . . . .PCD-134
PHP . . . . . . . . . . .PSD-206
7900 . . . . . . . . . . .PCD-150
PRTB . . . . . . . . . .PCD-112
7950 . . . . . . . . . . .PCD-156
R5750 . . . . . . . . . .RCD-26
900 . . . . . . . . . . . .RCD-10
RSD . . . . . . . . . . .ACC-336
900D . . . . . . . . . . .ACC-335
SD3 . . . . . . . . . . .ACC-336
9000 . . . . . . . . . . .DCD-94
TR . . . . . . . . . . . .ACC-338
BDS . . . . . . . . . . .ACC-335
TR DEEP . . . . . . . .ACC-338
BP . . . . . . . . . . . .LSD-190
WFO . . . . . . . . . . .UFD-332
D3 . . . . . . . . . . . .ACC-336
ACC-339