You are on page 1of 18

CONSOLIDATION TEST

PROJECT : SOIL INVESTIGASI


BORING NO.: DB.1 / UDS.1
DEPTH
: 3.00 - 3.50
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Brownish Red

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0670

cm

0.0373
0.25

1.0297

0.50

1.0130

1.00

0.9815

2.00

0.9450

4.00

0.8890

8.00

0.8175

2.00

0.8345

0.25

0.8650

3 2.635

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.807

97.98

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0167
0.0315
0.0365
0.0560
0.0715
0.0170
0.0305

END OF TEST

127.120
62.410
64.710
41.762
22.95
54.948

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.478

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.991

153.60

0.00542

1.432

1.963
0.977

240.60

0.00337

1.411

1.946
0.965

117.60

0.00672

1.372

1.915
0.948

101.40

0.00752

1.327

1.878
0.925

101.40

0.00716

1.257

1.822
0.893

135.00

0.00501

1.169

1.751

1.190

1.768

1.227

1.798

e = H/Hs e = eo - e

0.0462
0.0207
0.0390
0.0452
0.0694
0.0886
0.0211

0.880

0.0378

0.891

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.1 / UDS.1
: 3.00 - 3.50
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Brownish Red

: 0.00660
: 0.294
: 0.039

cm /sec

Coeff. of Volume Comp. (mv)

: 0.031

cm /kg

Void Ratio vs Applied Pressure

1.600

eo= 1.478

Void ratio (e)

1.400

1.200

1.000
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure

0.00806

Cv (cm2/sec)

0.00706
0.00606
0.00506
0.00406
0.00306
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.1 / UDS.2
DEPTH
: 5.50 - 6.00
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay,Reddish Brown

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0330

cm

0.0570
0.25

0.9760

0.50

0.9510

1.00

0.9070

2.00

0.8482

4.00

0.7680

8.00

0.6700

2.00

0.6845

0.25

0.7097

3 2.587

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.782

99.65

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0250
0.0440
0.0588
0.0802
0.0980
0.0145
0.0252

END OF TEST

124.110
60.560
63.550
39.716
23.83
60.011

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.558

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.986

135.00

0.00610

1.485

1.943
0.965

117.60

0.00672

1.453

1.918
0.948

101.40

0.00752

1.397

1.874
0.922

101.40

0.00711

1.322

1.815
0.888

101.40

0.00659

1.219

1.735
0.843

117.60

0.00512

1.094

1.637

1.112

1.652

1.144

1.677

e = H/Hs e = eo - e

0.0729
0.0320
0.0563
0.0752
0.1026
0.1253
0.0185

0.822

0.0322

0.832

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.1 / UDS.2
: 5.50 - 6.00
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay,Reddish Brown

: 0.00659
: 0.416
: 0.034

cm /sec

Coeff. of Volume Comp. (mv)

: 0.046

cm /kg

Void Ratio vs Applied Pressure

1.600

eo= 1.558

Void ratio (e)

1.400

1.200

1.000
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure

Cv (cm2/sec)

0.00806

0.00706

0.00606

0.00506

0.00406
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.1 / UDS.3
DEPTH
: 9.50 - 10.00 m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Clayey Silt, Greyish Brown

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0680

cm

0.0400
0.25

1.0280

0.50

1.0048

1.00

0.9660

2.00

0.9160

4.00

0.8390

8.00

0.7315

2.00

0.7450

0.25

0.7712

3 2.567

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.805

96.51

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0232
0.0388
0.0500
0.0770
0.1075
0.0135
0.0262

END OF TEST

123.010
59.780
63.230
40.591
22.64
55.772

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.483

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.990

117.60

0.00707

1.434

1.960
0.974

101.40

0.00794

1.405

1.937
0.959

153.60

0.00507

1.357

1.898
0.937

86.40

0.00861

1.295

1.848
0.905

194.40

0.00357

1.199

1.771
0.859

135.00

0.00463

1.066

1.664

1.082

1.677

1.115

1.703

e = H/Hs e = eo - e

0.0497
0.0288
0.0482
0.0621
0.0956
0.1335
0.0168

0.835

0.0325

0.845

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.1 / UDS.3
: 9.50 - 10.00
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Clayey Silt, Greyish Brown

: 0.00547
: 0.443
: 0.033

cm /sec

Coeff. of Volume Comp. (mv)

: 0.038

cm /kg

Void Ratio vs Applied Pressure

1.600

eo= 1.483

Void ratio (e)

1.400

1.200

1.000
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.00906

Cv (cm2/sec)

0.00806
0.00706
0.00606
0.00506
0.00406
0.00306
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.2 / UDS.1
DEPTH
: 3.00 - 3.50
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Brownish Red

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0410

cm

0.0435
0.25

0.9975

0.50

0.9792

1.00

0.9470

2.00

0.9050

4.00

0.8417

8.00

0.7622

2.00

0.7830

0.25

0.8190

3 2.621

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.806

97.42

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0183
0.0322
0.0420
0.0633
0.0795
0.0208
0.0360

END OF TEST

123.850
59.520
64.330
41.499
22.83
55.016

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.480

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.989

135.00

0.00615

1.426

1.957
0.974

101.40

0.00793

1.404

1.938
0.961

135.00

0.00580

1.364

1.906
0.943

101.40

0.00743

1.312

1.864
0.916

135.00

0.00527

1.233

1.801
0.880

264.60

0.00248

1.134

1.721

1.160

1.742

1.205

1.778

e = H/Hs e = eo - e

0.0539
0.0227
0.0399
0.0521
0.0785
0.0986
0.0258

0.866

0.0446

0.880

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.2 / UDS.1
: 3.00 - 3.50
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Brownish Red

: 0.00525
: 0.328
: 0.047

cm /sec

Coeff. of Volume Comp. (mv)

: 0.035

cm /kg

Void Ratio vs Applied Pressure

1.600

eo= 1.480

Void ratio (e)

1.400

1.200

1.000
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.00906

Cv (cm2/sec)

0.00806
0.00706
0.00606
0.00506
0.00406
0.00306
0.00206
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.2 / UDS.2
DEPTH
: 5.50 - 6.00
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Brownish Red

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0390

cm

0.0590
0.25

0.9800

0.50

0.9550

1.00

0.9130

2.00

0.8550

4.00

0.7742

8.00

0.6785

2.00

0.7000

0.25

0.7400

3 2.614

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.766

92.22

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0250
0.0420
0.0580
0.0808
0.0957
0.0215
0.0400

END OF TEST

121.230
59.560
61.670
39.332
22.34
56.793

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.610

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.985

86.40

0.00953

1.533

1.941
0.964

101.40

0.00778

1.500

1.916
0.948

101.40

0.00751

1.445

1.874
0.923

86.40

0.00835

1.370

1.816
0.888

153.60

0.00435

1.264

1.735
0.844

194.40

0.00310

1.139

1.640

1.167

1.661

1.220

1.701

e = H/Hs e = eo - e

0.0770
0.0326
0.0548
0.0757
0.1054
0.1249
0.0281

0.825

0.0522

0.841

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.2 / UDS.2
: 5.50 - 6.00
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Brownish Red

: 0.00583
: 0.415
: 0.053

cm /sec

Coeff. of Volume Comp. (mv)

: 0.047

cm /kg

Void Ratio vs Applied Pressure

2.000

eo= 1.610

Void ratio (e)

1.600

1.200

0.800
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.01006

Cv (cm2/sec)

0.00906
0.00806
0.00706
0.00606
0.00506
0.00406
0.00306
0.00206
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.2 / UDS.3
DEPTH
: 9.50 - 10.00 m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Greyish Brown

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0240

cm

0.0348
0.25

0.9892

0.50

0.9708

1.00

0.9350

2.00

0.8900

4.00

0.8278

8.00

0.7430

2.00

0.7570

0.25

0.7858

3 2.548

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.845

99.38

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0184
0.0358
0.0450
0.0622
0.0848
0.0140
0.0288

END OF TEST

125.700
60.900
64.800
42.256
22.54
53.352

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.368

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.991

194.40

0.00429

1.327

1.965
0.978

117.60

0.00690

1.305

1.947
0.964

135.00

0.00584

1.263

1.911
0.944

86.40

0.00875

1.209

1.866
0.917

101.40

0.00704

1.136

1.804
0.881

135.00

0.00487

1.035

1.719

1.052

1.733

1.086

1.762

e = H/Hs e = eo - e

0.0412
0.0218
0.0424
0.0533
0.0736
0.1004
0.0166

0.863

0.0341

0.874

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.2 / UDS.3
: 9.50 - 10.00
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Greyish Brown

: 0.00663
: 0.334
: 0.034

cm /sec

Coeff. of Volume Comp. (mv)

: 0.033

cm /kg

Void Ratio vs Applied Pressure

1.400

eo= 1.368

Void ratio (e)

1.300

1.200

1.100

1.000
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.00906

Cv (cm2/sec)

0.00806
0.00706
0.00606
0.00506
0.00406
0.00306
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.3 / UDS.1
DEPTH
: 3.00 - 3.50
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Reddish Brown

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0410

cm

0.0995
0.25

0.9415

0.50

0.9060

1.00

0.8410

2.00

0.7272

4.00

0.5740

8.00

0.3960

2.00

0.4190

0.25

0.4698

3 2.528

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.667

97.84

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0355
0.0650
0.1138
0.1532
0.1780
0.0230
0.0508

END OF TEST

121.040
62.310
58.730
33.132
25.60
77.263

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.996

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.975

101.40

0.00795

1.847

1.901
0.941

86.40

0.00870

1.794

1.865
0.916

101.40

0.00702

1.697

1.800
0.872

117.60

0.00548

1.526

1.686
0.805

194.40

0.00283

1.297

1.533
0.722

135.00

0.00327

1.030

1.355

1.064

1.378

1.141

1.429

e = H/Hs e = eo - e

0.1491
0.0532
0.0974
0.1705
0.2295
0.2667
0.0345

0.683

0.0761

0.702

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.3 / UDS.1
: 3.00 - 3.50
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Reddish Brown

: 0.00465
: 0.886
: 0.073

cm /sec

Coeff. of Volume Comp. (mv)

: 0.080

cm /kg

Void Ratio vs Applied Pressure

2.200

2.000

eo= 1.996

Void ratio (e)

1.800

1.600

1.400

1.200

1.000

0.800
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.00906

Cv (cm2/sec)

0.00806
0.00706
0.00606
0.00506
0.00406
0.00306
0.00206
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.3 / UDS.2
DEPTH
: 5.50 - 6.00
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Brownish Red

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0950

cm

0.0330
0.25

1.0620

0.50

1.0368

1.00

0.9870

2.00

0.9330

4.00

0.8610

8.00

0.7620

2.00

0.7870

0.25

0.8340

3 2.580

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.799

97.79

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0252
0.0498
0.0540
0.0720
0.0990
0.0250
0.0470

END OF TEST

123.300
59.770
63.530
40.467
23.06
56.992

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.504

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.992

101.40

0.00823

1.462

1.967
0.977

86.40

0.00937

1.431

1.942
0.958

86.40

0.00902

1.368

1.892
0.933

117.60

0.00627

1.301

1.838
0.901

153.60

0.00448

1.211

1.766
0.858

153.60

0.00407

1.087

1.667

1.118

1.692

1.177

1.739

e = H/Hs e = eo - e

0.0413
0.0315
0.0623
0.0676
0.0901
0.1239
0.0313

0.840

0.0588

0.858

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.3 / UDS.2
: 5.50 - 6.00
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Brownish Red

: 0.00596
: 0.412
: 0.060

cm /sec

Coeff. of Volume Comp. (mv)

: 0.038

cm /kg

Void Ratio vs Applied Pressure

1.600

1.500

eo= 1.504

Void ratio (e)

1.400

1.300

1.200

1.100

1.000
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.01006

Cv (cm2/sec)

0.00906
0.00806
0.00706
0.00606
0.00506
0.00406
0.00306
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000

CONSOLIDATION TEST
PROJECT : SOIL INVESTIGASI
BORING NO.: DB.3 / UDS.3
DEPTH
: 9.00 - 9.50
m

TESTED BY : Aji
DATE
: 25/03/2014

LOCATION : Bandara Halim Perdana Kusuma


DESCRIPT. : Silty Clay, Brownish Red

APPARATUS MEASUREMENTS
CONTAINER HEIGHT
CONTAINER DIAMETER
CONTAINER AREA (A)

:
:
:

DEGREE OF SATURATION IN %
TEST START
:
TEST END
:

2.000 cm
5.000 cm
19.635 cm2

BEGINNING OF TEST

CONTAINER NO.
WT. CONTAINER + WET SOIL IN g
WT. CONTAINER IN g
WT. WET SOIL IN g
WT. DRY SOIL (Ws) IN g
WT. WATER (Ww) IN g
WATER CONTENT (w) IN %

APPLIED

FINAL

DIAL

PRESSURE

DIAL

CHANGE
(H)

cm
1.0520

cm

0.0270
0.25

1.0250

0.50

1.0110

1.00

0.9830

2.00

0.9460

4.00

0.8880

8.00

0.8190

2.00

0.8412

0.25

0.8805

3 2.601

SOLIDS HEIGHT (Hs) IN cm


Hs = Ws/(Gs.w. A)

: 0.781

89.48

WATER CONTENT

kg/cm
0.00

SPECIFIC GRAVITY (Gs)

0.0140
0.0280
0.0370
0.0580
0.0690
0.0222
0.0393

END OF TEST

115.980
54.690
61.290
39.865
21.42
53.742

FITTING

AVERAGE
HEIGHT
FOR LOAD

TIME
(t 90)

cm

sec

1.562

cm
2.000

Cv
2
0.848 H
t 90
cm2/sec

0.993

153.60

0.00545

1.528

1.973
0.983

153.60

0.00533

1.510

1.959
0.973

173.40

0.00463

1.474

1.931
0.956

117.60

0.00659

1.426

1.894
0.933

317.40

0.00232

1.352

1.836
0.901

470.40

0.00146

1.264

1.767

1.292

1.789

1.342

1.829

e = H/Hs e = eo - e

0.0346
0.0179
0.0359
0.0474
0.0743
0.0884
0.0284

0.889

0.0503

0.904

CONSOLIDATION TEST
PROJECT
LOCATION

: SOIL INVESTIGASI
: Bandara Halim Perdana Kusuma

BORING NO.
DEPTH
TESTED BY

: DB.3 / UDS.3
: 9.00 - 9.50
: Aji

DATE
DESCRIPTION

: 25/03/2014
: Silty Clay, Brownish Red

: 0.00375
: 0.294
: 0.052

cm /sec

Coeff. of Volume Comp. (mv)

: 0.026

cm /kg

Void Ratio vs Applied Pressure

1.600

eo= 1.562

Void ratio (e)

1.500

1.400

1.300

1.200
0.10

1.00

10.00

Pressure, p (kg/cm2)

Cv vs Applied Pressure
0.00706

Cv (cm2/sec)

0.00606
0.00506
0.00406
0.00306
0.00206
0.00106
0.100

Coefficient of Consolidation (Cv)


Compression Index (Cc)
Swell Index (Cs)

1.000

Pressure, p (kg/cm2)

10.000