You are on page 1of 1

1.3 - STRAND PROPERTIES 15mm (0.

6)
Strand type
Nominal diameter
Nominal cross section
Nominal mass
Nominal yield strength
Nominal tensile strength
Specif./min. breaking load
Youngs modulus
Relaxation3 after 1000 h
at 20C and 0.7 x Fpk

d
Ap
M
fp0,1k
fpk
Fpk

prEN 10138 3 (2006)


Y1860S7
15.3
15.7
140
150
1.093
1.172
16361
16401
1860
1860
260
279

(mm)
(mm2)
(kg/m)
(MPa)
(MPa)
(kN)
(GPa)

ASTM A 416-06
Grade 270
15.24
140
1.102
16762
1860
260.7
approx. 195
max. 2.5

(%)

1) Characteristic value measured at 0.1% permanent extension


2) Minimum load at 1% extension for low-relaxation strand
3) Valid for relaxation class acc. to prEN 10138-3 or low-relaxation grade acc. to ASTM A 416-06

1.4 - TENDON PROPERTIES 15mm (0.6)


Strands
numbers

Steel area
ASTM

Y1860S7 (prEN)

d=15.3 mm d=15.7 mm
Ap=140 mm2 Ap=150 mm2

Ap acc. to prEN

Corrugated steel duct3 Corrugated plastic


(recommended)
duct VSL PT-PLUS
Grade 270 i / e
e
i / e
e

(ASTM)

Breaking load

6-1
6-2
6-3
6-4
6-7
6-7
6-12

6-12
6-15
6-15
6-19

6-19
6-22
6-22
6-27

6-27
6-31

6-31
6-37

6-37
6-43
6-55

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
43
55

d=15.24 mm
Ap=140 mm2

Steel
pipes
ext. x t

%CCENTRICITY

Unit

d=15.3 mm
Ap=140 mm2

d=15.7 mm
Ap=150 mm2

d=15.24 mm
Ap=140 mm2

[mm2]

[mm2]

[mm2]

[kN]

[kN]

[kN]

[mm]

[mm]

[mm]

[mm]

140
280
420
560
700
840
980
1120
1260
1400
1540
1680
1820
1960
2100
2240
2380
2520
2660
2800
2940
3080
3220
3360
3500
3640
3780
3920
4060
4200
4340
4480
4620
4760
4900
5040
5180
6020
7700

150
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
3150
3300
3450
3600
3750
3900
4050
4200
4350
4500
4650
4800
4950
5100
5250
5400
5550
6450
8250

140
280
420
560
700
840
980
1120
1260
1400
1540
1680
1820
1960
2100
2240
2380
2520
2660
2800
2940
3080
3220
3360
3500
3640
3780
3920
4060
4200
4340
4480
4620
4760
4900
5040
5180
6020
7700

260
520
780
1040
1300
1560
1820
2080
2340
2600
2860
3120
3380
3640
3900
4160
4420
4680
4940
5200
5460
5720
5980
6240
6500
6760
7020
7280
7540
7800
8060
8320
8580
8840
9100
9360
9620
11180
14300

279
558
837
1116
1395
1674
1953
2232
2511
2790
3069
3348
3627
3906
4185
4464
4743
5022
5301
5580
5859
6138
6417
6696
6975
7254
7533
7812
8091
8370
8649
8928
9207
9486
9765
10044
10323
11997
15345

260.7
521
782
1043
1304
1564
1825
2086
2346
2607
2868
3128
3389
3650
3911
4171
4432
4693
4953
5214
5475
5735
5996
6257
6518
6778
7039
7300
7560
7821
8082
8342
8603
8864
9125
9385
9646
11210
14339

25/30
40/45
40/45
45/501
50/57
55/62
55/62
65/72
65/72
70/77
70/77
75/82
80/87
80/87
80/87
85/92
85/92
90/97
90/97
100/107
100/107
100/107
100/107
100/107
110/117
110/117
110/117
110/117
120/127
120/127
120/127
120/127
120/127
120/127
130/137
130/137
130137
140/147
160/167

5
9
6
7
8
9
7
11
9
11
9
11
13
11
10
12
11
13
12
17
16
15
14
13
18
17
16
15
21
20
19
18
17
16
22
21
20
21
26

22/25
76/252
76/252
76/252
58/63
58/63
58/63
76/81
76/81
76/81
76/81
76/81
100/106
100/106
100/106
100/106
100/106
100/106
100/106
100/106
100/106
100/106
115/121
115/121
115/121
115/121
115/121
130/136
130/136
130/136
130/136
130/136
130/136
130/136
130/136
130/136
130/136
150/157
150/157

4
13
11
9
18
16
15
13
12
25
24
23
22
20
19
18
17
16
15
22
22
21
21
20
27
27
26
25
24
23
22
22
21
20
27
21

[mm]
25.0 x 2.0
33.7 x 2.0/2.5/3.0
42.4 x 2.0/2.5/3.0
48.3 x 2.0/2.5/3.0
76.1 x 2.0/2.5/3.0
76.1 x 2.0/2.5/3.0
80.0 x 2.0/.2.5

80.0 x 2.0/.2.5
101.6 x 3.0/4.0/5.0
101.6 x 3.0/4.0/5.0
101.6 x 3.0/4.0/5.0

101.6 x 3.0/4.0/5.0
108.0 x 3.0/4.0
114.3 x 3.0/4.0/5.0
114.3 x 3.0/4.0/5.0

114.3 x 3.0/4.0/5.0
127.0 x 3.0/4.0/5.0

127.0 x 3.0/4.0/5.0
139.7 x 3.0/4.0

139.7 x 3.0/4.0
152.4 x 3.0/4.0/5.0
168.3 x 3.0/4.0

1) Flat ducts possible as well


2) Flat duct PT-PLUS with rectangular slab anchorages, for PT-PLUS see also under 3.1.3.
3) If flat ducts (steel or PT PLUS) to be used with square type castings please contact your VSL representative. In plan view, tendons with slab type anchorages must be straight between anchorages or have only unidirectional turns with
min. radii of > 6 m. Strands must always be pushed-in prior to concreting. Eccentricity e: negligible
4) Given values may slightly vary depending on local availability of ducts. They are minimal for most applications. For special cases (long tendons, many curvatures, small radii etc.) greater size duct is recommended please verify with
VSL. In any case the filling ratio (cross-section steel / duct) must not exceed 0.5 (EN523).
5) Please check with the nearest VSL office for the complete anchorage list.

V S L P O S T- T E N S I O N I N G S O L U T I O N S



You might also like