Qarqet me llampa
Parathnie ............................................................................................................................. 1
Ndrprersit e rryms / elsat .............................................................................................. 7
elsat dhe prizat sipas standarteve europiane .................................................................. 13
Lidhja e elsit n seri me priza t tokzuara ..................................................................... 19
elsat me priza mbrojtse kontakti .................................................................................... 25
elsat kryq me priza mbrojtse kontakti ............................................................................ 31
Paraqitja e t dhnave t nj qarku ..................................................................................... 37
Qarqet me llampa me gazra halogjene
Parathnie ........................................................................................................................... 41
Detyr kursi .......................................................................................................................... 43
Qarqet me llampa me gazra halogjene (qarqet e mbyllura) ................................................ 47
Qarqet me llampa me gazra t rralla ndriuese (qarqet n seri) .......................................... 53
Qarqet e llojit tandem ............................................................................................................ 59
Qarqet dyshe ........................................................................................................................ 65
Qarqet me llampa kompakte me gazra halogjene dhe kompensues ................................... 71
Test i prgjithshm .............................................................................................................. 75
Udhzim
Teknika e instalacioneve elektrike ndahet n shum kategori t ndryshme, t cilat n radh
t par prcaktohen nga fusha e prdorimit. Ndr kategorit m kryesore vlejn t
prmenden:
Po ashtu teknika e instalacioneve elektrike kategorizohet edhe duke patur si kriter teknikn e
prdorur, si p.sh.:
* Dimmen Me Dimmen nnkuptohen Tiristori / Reostati ose elsat triac dimmer, t cilt prdoren pr
t kontrolluar ndriimin n llamba (p.s., n tribuna, llampa ose transformator t tensionit t ult prej
llambave halogjene). Dimmer-at mund t prdoren pr t kontrolluar konsumin e energjis s
konsumatorve t tjer, t prdorur n qarqe t ngjashme, si n fshesat me vakum t shtpis dhe
trapanot e dors, n t ciln sht e domosdoshme ndryshimi i fuqis s puns.
** Q nga viti 1999 Fieldbus-et jan standartizuar sipas norms ndrkombtare IEC 61158 ("Digital data
communication for measurement and control - Fieldbus for use in industrial control systems").
EIT PARATHNIE
EIT PARATHNIE
Schukostekdose
Verteilerdose
Glhlampenfassung
Serienschalter
Kreuzschalter
Aus- / Wechselschalter
Wechselstromeinspeisung
EIT PARATHNIE
Kriteret teorike
Kriteret teorike jan nj prmbledhje e shkurtr e kapitullit t tekniks s qarqeve nga libri Fachkunde Elektrotechnik (Verlag
Europa Lehrmittel).
Teknika e instalimit nuk varet vetm nga mnyra praktike e realizimit t instalimeve, por edhe
nga leximi dhe ndrtimi i skicave t planeve, t cilat mundsojn nj pun t pandrprer n
ndrtesn ku duhet t kryhen ndrtimet. Pr t mundsuar nj komunikim t suksesshm
ndrmjet firmave t ndryshme, arkitektve, projektuesve, teknikve dhe zbatuesve duhet t
krijohet nj mjet komunikimi i posam. Ky mjet komunikimi sht i prdorshm pothuajse n
t gjitha fushat e ndrtimit / zbatimit. N tekniken e instalimeve elektrike gjejn zbatim si
mjete komunikimi nj mori planesh.
Llojet e ktyre planeve t instalimeve elektrike:
Plani i instalimit
Plani i prgjithshm pasqyrues i instalimit
Plani i rrjedhjes s rryms me form t zmadhuar
Plani i rrjedhjes s rryms n paraqitjen e pjesve q ndrveprojn s bashku
Plani funksional
Plani i lidhjes
N secilin prej ktyre planeve do t prcaktohet mnyra dhe forma (nj-polshe, shumpolshe), se si pjest e veanta elektrike do t ndrveprojn s bashku n procesin e puns.
Plani i prshkrimit dhe i instalimit prbjn bazn elementare t puns pr instalimin e nj
rrjeti t caktuar, por ato nuk na japin asnj informacion mbi funksionimin e qarqeve. Skicat e
planeve t qarqeve prbjn bazn kryesore pr ndrtimin e qarqeve elektrike. Ato na
paraqesin n mnyre direkte funksionimin e qarqeve t kontrollit dhe t instalimit.
N detyrn e paraqitur pr zgjidhje planet e instalimit luajn nj rol shum t rndsishm.
Prshkrimi
Paraqitja
NYM Cu 1,5 mm
E1
Q1
Kinderzimmer
EIT PARATHNIE
Leitungsmaterial
Aderzahl
Abzweigdose
Ausschalter
Schutzkontaktsteckdose
PE
E1
Q1
N
PE
Q1
EIT PARATHNIE
E1
SO5148-1F
SO5126-9X
20
SO5126-9Z
10
SO3211-1D
els dysh
SE2661-1C
els (SPDT = Single Pole Double Throw ose DPDT = Double Pole Double Throw)
SE2661-1D
SE2661-6E
SE2661-1F
Priz degzuese
SE2661-1S
SO5123-9D
SE2661-9E
ST7003-....
SO5148-1F
SO5126-9X
20
SO5126-9Z
10
SO5151-6A
* els MCB (Miniature Circuit Breaker) jan elsa me sigures kundra mbinxehjes nga rryma e lart.
** Filtrat EMV prdoren pr t evituar problemet me fushn elektromagnetike t qarkut
EIT PARATHNIE
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
Sistemi i kutive
Zhvillimi i eksperimentit
Funksioni i elsit:
elsi mats
Plani i instalimit
11
12
T kuptoj funksionin e nj elsi n prgjithsi dhe t prizave sipas standarteve europiane n veanti.
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
13
N
PE
Sistemi i kutive
N
PE
230V/50Hz
14
Zhvillimi i eksperimentit
15
Funksioni i elsit:
elsi mats
PE
E1
Q1
16
Plani i instalimit
3
3
3
3
N
PE
E1
Q1
17
18
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
19
230V/50Hz
N
PE
Sistemi i kutive
N
PE
230V/50Hz
20
Zhvillimi i eksperimentit
Kontrolloni funksionimin e elsit n seri me nj multimetr (ose Ohmmetr). Dokumentoni vzhgimet tuaja.
N varsi t hapsirs s prcaktuar pr instalimin e pjesve t veanta aplikoni dhe
prfundoni planin e instalimit, duke vendosur aparaturat dhe pajisjet sipas standarteve t
prcaktuara.
Prfundoni nj skem instalimi n nj paraqitje t zmadhuar t planit dhe shpjegoni verbalisht funksionin e qarkut.
Prfundoni nj skem t ndrtimin t prgjithshm t planit t rryms duke paraqitur t
gjitha pjest e ndrvarura. Kini kujdes ta pasqyroni planin mundsisht pa lidhje t
kryqzuara.
Ndrtoni qarkun sipas udhzimeve tuaja dhe kontrollojeni at n munges t tensionit t
rryms me an t aparateve si multimetri, aparati i kontrollit t rryms, ohmmetri etj.
Duke patur asistencn e nj personi t kualifikuar vendoseni qarkun e ndrtuar prej jush
n gjndje pune.
T dy llampat duhet t ndizen dhe t fiken n mnyr t pavarur nga i njjti els. Gjithashtu qarku duhet t prmbaj nj priz t pavarur sipas standarteve europiane
21
Qarku mats
Aparatura matse tregon: n varsi t prdorimit tasts / levs s djatht apo t majt
prbashkt kontakti.
Pruesi i jashtm L1 do t mbrthehet n pikn e kontaktit
Planet e qarkut:
Paraqitja e qarkut n ambjent
Q1.1
Q1.2
E1
E2
22
Plani i instalimit
3
4
5
Q1.2
E1
E2
Q1.1
23
24
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
25
230V/50Hz
N
PE
Sistemi i kutive
N
PE
230V/50Hz
26
Zhvillimi i eksperimentit
Llampa duhet t ndizet dhe t fiket n mnyr t pavarur nga t dy elsat. Gjithashtu
qarku duhet t prmbaj nj priz t pavarur sipas standarteve europiane.
27
elsi mats
Aparati mats tregon n varsi OL (i pafund) nga nj kontakt dhe 0 Ohm nga tjetri.
Pasi prdorim elsin ndyshojn t dhnat n kontaktet e daljes
Ndrprersi i rryms sht nj els dypolsh me pika kontakti t ndara
Planet e qarkut:
Paraqitja e qarkut n ambjent
N PE
E1
Q1
Q2
28
Plani i instalimit
4
5
E1
Q1
Q2
29
30
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
31
N
PE
Sistemi i kutive
N
PE
230V/50Hz
32
Zhvillimi i eksperimentit
Kontrolloni funksionimin e elsit kryq dhe t nj prize me nj multimetr (ose Ohmmetr). Dokumentoni vzhgimet tuaja.
N varsi t hapsirs s prcaktuar pr instalimin e pjesve t veanta aplikoni dhe
prfundoni planin e instalimit, duke vendosur aparaturat dhe pajisjet sipas standarteve t
prcaktuara.
Prfundoni nj skem instalimi n nj paraqitje t zmadhuar t planit dhe shpjegoni
verbalisht funksionin e qarkut.
Prfundoni nj skem t ndrtimin t prgjithshm t planit t rryms duke paraqitur t
gjitha pjest e ndrvarura. Kini kujdes ta pasqyroni planin mundsisht pa lidhje t
kryqzuara.
Ndrtoni qarkun sipas udhzimeve tuaja dhe kontrollojeni at n munges t tensionit t
rryms me an t aparateve si multimetri, aparati i kontrollit t rryms, ohmmetri etj.
Duke patur asistencn e nj personi t kualifikuar vendoseni qarkun e ndrtuar prej jush
n gjndje pune.
Llampa duhet t ndizet dhe t fiket n mnyr t pavarur nga t tre elsat. Gjithashtu
qarku duhet t prmbaj njrn ose t dyja prizat e pavarura sipas standarteve
europiane.
33
elsi mats
34
Plani i instalimit
5
5
5
5
E1
Q1
Q2
Q3
35
36
Zhvillimi i eksperimentit
37
Kushtet paraprake
Plani i instalimit bashk me informacionet e lidhura me t jepen si m posht:
38
Prcjellsit
Siguresat
3x1,5 NYM
5x2,5 NYM
LS B16A
3xLS B16A Priza e vatrs
3x1,5 NYM
LS B16A
3x1,5 NYM
LS B16A
3x1,5 NYM
3x1,5 NYM
LS B16A
FI 30mA,
LS B16A
Kuzhin, Prizat
Banjo
Lidhje e mbyllur
8
3
Korridor
Dhom ndenje
Lidhje kryq
Lidhja n seri
2
9
3x1,5 NYM
3x1,5 NYM
LS B16A
LS B16A
Dhom gjumi
Lidhja kryq
3x1,5 NYM
LS B16A
Dhom fmijsh
Rezerv
Lidhje e mbyllur
3x1,5 NYM
LS B16A
LS B16A
Informacionet
shtes
Priza sipas
standarteve
eurupiane
Priza sipas
standarteve
europiane
Priz rroj,
ndrprerse
rryme
Lidhje shtes
pr nj llamp
muri
Lidhje shtes
pr nj llampe
muri
39
N PE
3
L1
Kche
(Licht)
Kche
(Herd)
Kche
(Splmaschine)
Kche
(Waschmaschine)
Kche
(Steckdosen)
F1.1
L16A
L1,2,3
F1.2
L2
L16A
F1.3
L3
L16A
F1.4
4
400V; 3/N
~ 50Hz
4
3
L1
L16A
F1.5
F1.01
F1.02
F1.03 (63A)
PE
H07V- U 16mm
F1.04
63A
0,5A
2
L2
L16A
F1.6
L3
L16A
F1.7
L1
L16A
F1.8
L2
L16A
F1.9
L3
L16A
10
F1.10
L1
L16A
Badezimmer
Flur
Wohzimmer
Schlafzimmer
Kinderzimmer
11
F1.11
L16A
40
Ushqyes
Llamp ndriimi
els / Startues
Vrejtje: Gjat aplikimit n praktik jan t mundura shmangie t vogla nga skica e msiprme
EIT PARATHNIE
41
SO5148-1F
SO5126-9X
20
SO5126-9Z
10
SO3211-1D
42
EIT PARATHNIE
Detyr kursi
Sipas porosis s klientit elektriisti duhet t instaloj nj sistem ndriimi n tavanin e varur
t dhoms s puns.Llojin e ndriimit dhe dekorimin (llampa t thjeshta, llampa me gazra t
rralla p.sh. llampa neoni) e prcakton vet klienti.
Fuqia e ndriimit E
Fuqia e ndriimit tregon sesa sasi drite rrezatohet n nj siprfaqe t caktuar.
43
Fluksi i drits
730 lm
Fuqia e drits
55 cd
345 cd
12,16 lm/W
93,10 lm/W
5-10 %
25%
Llamp me 60 W
Konsumi i drits
Shkalla e veprimit
44
Llampa me gaz t rrall prbhet nga nj tub qelqi n skajet e t cilit jan t vendosura
elektrodat e drits (pruesi i nxeht n form spirale). Pjesa e brendshme e tubit t qelqit
sht e lyer nga nj material ndriues. Ky material ka aftsin t kthej dritn e padukshme
n drit t dukshme. Tubi i qelqit sht mbushur me nj przierje t prbr prej gazi t
rrall dhe argjend i lngshm. Llampat me gazra t rrall nuk mud t lidhen direkt n rrjetin e
rryms por pr tu montuar dhe pr tu vn n pun ato kan nevoj pr nj ndezs
(vendoss kontakti) dhe nj aparat parandezs
Funksionimi i nj llampe me gaz t rrall
Vnia n pun e nj llampe me gaz t rrall kalon npr katr faza:
Faza 1: Shklqimi
E hapim elesin e drits, por do t shikojm q furnizimi i llamps me tension t rryms
nuk mjafton q sasia mbushse e gazit n llamp t ndizet. Tensioni i rryms qndron
edhe n ndezs, i cili sht lidhur paralel me llampn me gaz t rrall. Elektrodat e
ndezsit jan ndrtuar n formn e dy fijeve metali q kur takohen me njra-tjetrn
bjn ndezjen e llamps, pra luajn rolin e nj elsi. Tashm ndezsi ka nj tension
t mjaftueshm pr t krijuar ngarkimin e shkndijs, kshtu q vlera e intensitetit (imin)
mund t kaloj npr mbushjen e gazit t ndezzit. N siprfaqen e elektrodave t
ndezzit qndron nj shtres gazi e ngarkuar q shrben si shkndij pr t ngrohur fijet e metalit duke krijuar kontaktin midis tyre.
45
Faza 2: Ndriimi
Prmes ngrohjes s fijeve t metalit n pikn e tyre t kontaktit mund t bhet prkulja
dhe takimi i tyre, gj q realizon mbylljen e qarkut. Vetm se npr aparatin parandezs, n spiralen e nxeht t llamps me gaz t rrall,duhet t kaloj nj vler m e
lart intensiteti sesa vlera e intensitetit t ndezjes (iHeiz).Spiralja e nxeht fillon t
ndrioj dhe elektronet e ngarkuara t dala prej saj mund ta ngarkojn edhe gazin me
mbarts t ngarkess elektrike. Gjat ndriimit avullohet edhe nj pjes e vogl e argjendit t lngshm.
Faza
3:
Ndezja
Pasi sht arritur kontakti i fijeve t metalit n ndezs nuk mund t krijohen m
shkndija t ngarkuara dhe kshtu fijet e metalit n pikn e tyre t kontaktit fillojn t
ftohen. Pasi ato arrijn nj temperatur t caktuar ftohje ato hapin menjher qarkun e
nxeht t rryms dhe ndrpresin rrymn e nxeht. Spiralja e nxeht n llampn me gaz
t rrall ndrion pr shkak t elektroneve t ngarkuara q gjenden rreth saj. Pr shkak
t ndrprerjes s menjhershme t rryms s nxeht n bobinn e kufizuesit kemi nj
vler t lart tensioni induktiv, tensioni i ndezjes q mund t arrij deri n vlern
1000V. Ky tension i lart e ndez gazin n llampn me gaz t rrall (llampa neoni) dhe
bn q t kaloj rrym nga njra elektrod n tjetrn.
Faza 4: Djegja
Prmes aparatit parandezs vlera e intensitetit t rryms n llamp do t kufizohet.
Tensioni i rrjetit do t ndahet midis aparatit parandezs dhe llamps me gaz t rrall.
Pjesa e vlers s tensionit n llampn me gaz t rrall quhet ndryshe edhe tensioni
djegs i cili kap vlerat 50 deri n 110V. Duke qen se ndezsi sht i lidhur paralel me
llampn kjo lloj vlere tensioni, e cila sht tepr e vogl pr t krijuar nj shkndij t
re t ngarkuar gjendet edhe tek ai.
46
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
47
Plani i instalimit
Bordi i instalimit
Vrejtje: Gjat aplikimit n praktik jan t mundura shmangie t vogla nga skica e msiprme
48
Detyr:
Nj llamp halogjene duhet t komandohet (t fiket dhe ndizet) prmes nj elsi.
Zhvillimi i eksperimentit
49
Planet e qarkut:
50
Plani i instalimit
51
52
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
53
Plani i instalimit
Bordi i instalimit
Vrejtje: Gjat aplikimit n praktik jan t mundura shmangie t vogla nga skica e msiprme
54
Detyr:
Dy llampa halogjene duhet t komandohen (t fiken dhe ndizen) prmes nj elesi n
mnyr t pavarur.
Zhvillimi i eksperimentit
55
Planet e qarkut:
56
Plani i instalimit
57
58
T kuptoj dhe sqaroj funksionin e nj qarku t tipit tandem duke patur pr baz nj
plan konkret instalimi.
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N proesin e lidhjes s portollamps duhet t kemi parasysh q n pruesin e jashtm, (ku
furnizimi me rrym sht i hapur), duhet t ndrpritet furnizimi me rrym deri kur ai t vihet
n kontakt me portollampn.
59
Plani i instalimit
Bordi i instalimit
Vrejtje: Gjat aplikimit n praktik jan t mundura shmangie t vogla nga skica e msiprme
60
Detyr
T dy llampat me gazra t rralla duhet t lidhen me nj aparat parandezs t prbashkt n
nj qark t tipit tandem dhe t komandohen (ndizen e t fiken) nga nj els i prbashkt.
Zhvillimi i eksperimentit
61
Planet e qarkut:
Paraqitja e qarkut n ambjent
62
Plani i instalimit
63
64
Qarqet dyshe
Objektivat
Pasi t zhvilloj eksperimentin nxnsi do t jet i aft:
T shpjegoj funksionin e ngritjes s efektit stroboskopik ose sic quhet ndryshe efekti
flimer (valt e drits).
Prshkrimi / Udhzimet
N hartimin dhe n ndrtimin e nj plani duhet t kemi parasysh q, n pruesin e jashtm
(L1) rryma duhet t jet e hapur pasi n munges t rryms konsumuesi nuk do t krijoj
potencial tensioni n raport me tokn.
Gjat proesit t skicimit t planeve dhe ndrtimit t elsave, t gjitha planet e qarqeve do
t vendosen n gjendje t mbyllur dhe ndrtimi i tyre duhet t bhet duke patur parasysh
vendosjen e sakt t elementve prbrs.
N qarqet me llampa me gazra t rralla duhet patur kujdes q prcuesi i jashtm t lidhet me
indikatorin.
Bni kujdes q dy rratht e llampave t lidhen paralel me njra tjetrn dhe n rrethin e nj
llampe t lidhet nj kondensator shtes, i cili t jet aq i madh sa ky rreth t krijoj produktivitet t induksionit kapacitativ.
Kjo gj do na sillte kto prparsi:
1. Produktiviteti i induksionit kapacitativ i nj rrethi kompenson produktivitetin e induksionit induktiv t rrethit tjetr, kshtu q n skajet e rrjetit nuk do t ket rrym induktive dhe faktori i produktivitetit do ti afrohet vlers 1.
2. Vlera e intensiteteve t rryms n rratht e llampave induktive dhe kapacitative jan
larguar n kohzgjatje kaq shum nga njra-tjetra aq sa valt e drits (filmmerefekt)
jan zvogluar dhe kshtu sht ngritur efekti stroboskopik.
65
Vrejtje: Gjat aplikimit n praktik jan t mundura shmangie t vogla nga skica e msiprme
66
Detyrat:
Dy llampa me gazra te rralla (secila 8 W) duhet t lidhen n nj qark dysh ku t ndizen e t
fiken nga nj cels i prbashkt.
Zhvillimi i eksperimentit
Duke u nisur nga skema e instalimit dhe hapsira n ambjent, plotsoni planin n fjal.
Emrtoni aparaturat dhe linjat sipas standarteve elektrike.
Prfundoni nj skem instalimi n nj paraqitje t zmadhuar t planit dhe shpjegoni
verbalisht funksionin e qarkut.
Prfundoni nj skem t ndrtimin t prgjithshm t planit t rryms duke paraqitur t
gjitha pjest e ndrvarura. Kini kujdes ta pasqyroni planin mundsisht pa lidhje t
kryqzuara.
Ndrtoni qarkun sipas udhzimeve tuaja dhe kontrollojeni at n munges t tensionit t
rryms me an t aparateve si multimetri, aparati i kontrollit t rryms, ohmmetri etj.
Kini parasysh, q t dyja llampat t jen t lidhura n paralel, ndrkoh q kondensatort
t jen t lidhur n seri me nj bobin.
Duke patur asistencn e nj personi t kualifikuar vendoseni qarkun e ndrtuar prej jush
n gjndje pune.
67
Planet e qarkut:
Paraqitja e qarkut n ambjent
68
Plani i instalimit
69
70
Prshkrimi / Udhzimet
Pjes prbrse e indikatorit sht produkti induktiv, i cili sht rezultati i raportit midis
tensionit dhe rryms s induktuar, e cila sht ajo pjes e rryms me tension n form sinusi
me 90 grad. N rast se lidhim n nj qark me lidhje paralel kondensatorin konpensues
ather rendimenti ose produkti induktiv do t luhatet midis induktorit dh kondensatorit pr
sa koh q rrjeti nuk do t furnizohet me rrym induktive.
Vlera e faktorit t produktivitetit prmirsohet prmes kompensimit t produktivitetit induktiv
nga 0,3 n 0,5.
71
Vrejtje: Gjat aplikimit n praktik jan t mundura shmangie t vogla nga skica e msiprme
72
Detyrat:
Produktivitetit i nj llampe me gazra halogjene duhet t kompensohet me an t nj
kondensatori.
Zhvillimi i eksperimentit
73
PLlamp =
9,34
Pa konpensues
S=
cos =
74
32
0,29
Me konpensues
VA
S=
9,36
cos =
0,99
VA
Test i prgjithshm
Cilat nga dy funksionet e mposhtme ka nj induktor (paraels) n qarqet me llampa me
gazra t rralla?
T mbaj t lir rrjetin e rryms elektrike nga ajo pjes e saj e cila paraqet tensionin
n form sinusi n 90 grad.
N cilat qarqe me llampa me gazra t rralla ndriuese ndodh ngritja e efektit stroboskopik?
75