Professional Documents
Culture Documents
F 994 - 86 R01 - Rjk5na - PDF
F 994 - 86 R01 - Rjk5na - PDF
1. Scope
1.1 This specification covers carbon steel overboard discharge hull penetrations for system piping of NPS 1 through
NPS 24 (see Note 1).
Penetration
Pipe Size,
NPS
1
1
1
2
2
3
4
5
6
8
10
12
14
16
18
20
22
24
1.2 The minimum pipe schedule and reinforcement dimensions presented in Tables 1-6 are based on specifications in 46
CFR, 56.50-95 and Navy Design Data Sheet 100-1.
1.3 This specification does not include sea chest penetrations.
1.4 This specification does not include penetrations in
protective plating.
2. Referenced Documents
2.1 ASTM Standards:
A 519 Specification for Seamless Carbon and Alloy Steel
Mechanical Tubing2
2.2 ANSI Standard:
B36.10 Welded and Seamless Wrought Steel Pipe3
2.3 Military Document:
MIL-STD-1689 Fabrication, Welding, and Inspection of
Ships Structure4
2.4 Other Documents:
Title 46 Code of Federal Regulations (CFR), Subchapter F,
Marine Engineering4
Department of the Navy, Bureau of Ship Design Data Sheet
100-15
58
34
78
118
138
80
80
80
80
80
80
80
80
80
80
60
60
60
40
40
40
40
40
80
160
160
160
80
80
80
80
80
80
60
60
60
60
40
40
40
40
160
160
160
160
160
160
120
80
80
80
60
60
60
60
60
60
60
60
160
160
160
160
160
160
120
120
120
80
80
80
80
60
60
60
60
60
160
XXS
160
160
160
160
120
120
120
100
80
80
80
80
60
60
60
60
160
XXS
XXS
160
160
160
120
120
120
100
100
80
80
80
80
60
60
60
XXS
XXS
XXS
160
160
160
160
120
120
100
100
100
80
80
80
80
80
60
XXS
XXS
XXS
XXS
XXS
160
160
160
120
120
100
100
100
80
80
80
80
60
XXS
XXS
XXS
XXS
XXS
XXS
160
160
160
120
120
100
100
100
80
80
80
80
See Fig. 1.
1
This specification is under the jurisdiction of ASTM Committee F25 on Ships
and Marine Technology and is the direct responsibility of Subcommittee F25.11 on
Machinery and Piping Systems.
Current edition approved March 27, 1986. Published June 1986.
2
Annual Book of ASTM Standards, Vol 01.01.
3
Available from American National Standards Institute, 25 W. 43rd St., 4th
Floor, New York, NY 10036.
4
Available from Superintendent of Documents, U.S. Government Printing
Office, Washington, DC 20402.
5
Available from Department of the Navy, Naval Sea Systems Command,
Washington, DC 20362.
6
Available from American Bureau of Shipping, ABS Plaza, 16855 Northchase
Dr., Houston, TX 77060.
Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
F 994 86 (2001)
TABLE 2 Doubler Plate Dimensions (TD 3 D) Type II Penetration, NPS 1 Through NPS 24 (in. 3 in.)A
Penetrating
Pipe Size,
NPS, SCH
to
1, 80
1, 80
1, 80
2, 80
2, 80
3, 80
4, 80
5, 80
6, 80
8, 80
10, 60
12, 60
14, 60
16, 40
18, 40
20, 40
22, 60
24, 40
A
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
38
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
34
58
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
5
6
6
7
7
8
9
10
12
14
16
18
20
22
24
26
28
30
5
6
6
7
7
8
9
10
12
14
16
18
20
22
24
26
28
30
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
78
5
6
6
7
7
8
9
10
12
14
16
18
20
22
24
26
28
30
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5
6
6
7
7
8
9
10
12
14
16
18
20
22
24
26
28
30
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
118
5
6
6
7
7
8
9
10
12
14
16
18
20
22
24
26
28
30
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5
6
6
7
7
8
9
10
12
14
16
18
20
23
25
27
29
31
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
138
5
6
6
7
7
8
9
10
12
14
16
18
20
22
24
26
28
30
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5
6
6
7
7
8
9
10
12
14
16
18
20
23
25
27
29
31
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5
6
6
7
7
8
9
10
12
14
16
18
20
24
28
30
32
33
TABLE 3 Insert Plate Dimensions (TI 3 D), NPS 1 Through NPS 24 (in. 3 in.)A
Penetrating
Pipe Size,
NPS, SCH
to
1, 80
1, 80
1, 80
2, 80
2, 80
3, 80
4, 80
5, 80
6, 80
8, 80
10, 60
12, 60
14, 60
16, 40
18, 40
20, 40
22, 60
24, 40
A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
8
8
834
9
10
10
11
12
13
14
16
18
21
23
25
27
29
31
58
1
118
118
118
118
118
118
118
118
118
118
118
118
118
118
118
118
118
18
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
34
8
8
834
9
10
1034
11
12
13
14
17
18
21
23
25
27
29
31
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
8
834
9
9
10
1034
1134
13
14
15
18
19
21
23
25
27
29
31
78
1
138
138
138
138
138
138
138
138
138
138
138
138
138
138
138
138
138
38
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1 3 9
1 3 9
1 3 9
1 3 10
1 3 10
1 3 11
1 3 12
1 3 13
1 3 14
1 3 16
1 3 18
1 3 20
1 3 2134
134 3 26
134 3 27
178 3 30
178 3 30
178 3 34
8
9
9
934
10
11
12
13
14
16
18
20
21
24
25
28
30
31
34
1
158
158
158
158
158
158
158
158
158
158
158
158
218
218
218
218
218
58
118
138
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1 3 9
134 3 10
134 3 10
134 3 10
134 3 11
134 3 1134
134 3 1234
134 3 1334
134 3 1434
134 3 17
2 3 2034
2 3 2234
2 3 24
238 3 28
238 3 30
238 3 32
238 3 33
238 3 36
1 39
178 3 10
178 3 10
178 3 11
178 3 11
178 3 12
178 3 13
178 3 14
178 3 15
2 3 18
238 3 2234
238 3 2434
238 3 26
258 3 2934
258 3 3134
258 3 3334
258 3 34
258 3 38
9
9
10
10
1034
11
12
13
14
16
1834
2034
22
27
29
31
30
35
34
78
1
34
2 3 10
2 3 10
2 3 1034
2 3 11
2 3 11
2 3 12
2 3 13
218 3 15
218 3 16
2 3 19
2 3 23
2 3 25
258 3 2534
278 3 31
278 3 33
278 3 35
278 3 36
278 3 39
Sleeve Material
4. Materials
5. General Requirements
5.1 Overboard discharges shall be combined to the maximum extent practicable to minimize the number of shell
penetrations.
5.2 A minimum of 3 in. shall be maintained between the
edge of penetrations and shell plate welding seams. Penetrations shall be located so as to provide sufficient space for
2
F 994 86 (2001)
TABLE 4 Reinforcing Sleeve Dimensions, NPS 1 Through NPS 5 (Seamless Steel Tubing)A
Penetration
Pipe Size,
NPS, SCH
14
1, 80
114 , 80
112 , 80
2, 80
212 , 80
3, 80
4, 80
5, 80
outer diameter
wall thickness
length
outer diameter
wall thickness
length
outer diameter
wall thickness
length
outer diameter
wall thickness
length
outer diameter
wall thickness
length
outer diameter
wall thickness
length
outer diameter
wall thickness
length
outer diameter
wall thickness
length
178
134
214
932
134
212
932
134
318
516
134
4
12
134
412
716
134
614
1316
134
658
1 2
2
14
58
34
78
178
14
178
214
932
178
212
932
178
318
516
178
4
12
178
412
716
178
614
1316
178
758
1
2
178
14
2
214
932
2
212
932
2
318
516
214
4
12
2
412
716
214
614
1316
2
758
1
2
218
218
214
932
218
3
12
218
318
516
212
4
12
218
412
716
234
614
1316
218
758
1
218
218
214
3
58
214
3
12
214
4
34
214
4
12
212
412
716
3
614
1316
212
758
1
212
38
38
118
114
138
112
218
238
3
58
238
3
12
238
4
34
238
4
12
234
412
716
338
614
1316
234
8
1316
212
218
38
212
3
58
212
3
12
212
4
34
212
4
12
3
458
12
312
614
1316
3
858
112
212
218
38
258
3
58
258
3
12
234
4
34
258
4
12
312
458
12
334
614
1316
314
858
112
234
218
38
3
3
58
234
3
12
3
4
34
234
4
12
358
458
12
418
614
1316
312
858
112
3
38
See Fig. 6.
TABLE 5 Reinforcing Sleeve Dimensions, NPS 6 Through NPS 12 (Machined Seamless Steel Tube)A
Penetration
Pipe Size,
NPS, SCH
78
118
138
8
634
134
10
834
2
12
1078
8
634
2
10
834
234
12
1078
8
634
2
10
834
234
12
1078
8
634
2
10
834
3
1234
1078
9
634
2
11
834
3
1338
1078
9
634
234
11
834
3
1338
1078
9
634
234
11
834
3
1338
1078
9
634
3
11
834
3
14
1078
10
634
3
12
834
3
14
1078
length
tube outer diameter
machined inner diameter
234
14
1278
3
1438
1278
3
1438
1278
3
15
1278
3
15
1278
3
16
1278
334
16
1278
334
16
1278
4
16
1278
length
334
334
6, 80
8, 80
10, 60
12, 60
58
See Fig. 6.
welding between the penetration and shell longitudinals, stiffeners, or other structural members.
5.3 Shell penetrations located above the light load line shall
be clear of side ports, accommodation ladders, lifeboathandling areas, or other areas where discharge overboard is
detrimental to normal operation of the vessel or would create a
nuisance for personnel or other vessels in the area.
5.4 Overboard discharges shall be located to minimize
recirculation into suction seachests.
5.5 Shell penetrations shall be located outside of cathodic
protection areas.
5.6 Unfavorable flow characteristics may result when small
diameter, extreme schedule penetration pipe is used in accordance with Table 1. In this case, minimum allowable schedule
F 994 86 (2001)
TABLE 6 Reinforcing Sleeve Dimensions, NPS 14 Through NPS 24 (Rolled Steel Flatbar or Plate)A
Penetration
Pipe Size,
NPS, SCH
14
14, 60
16, 40
18, 40
20, 40
22, 60
24, 40
inner diameter
wall thickness
length
34
inner diameter
wall thickness
length
34
58
34
78
118
114
138
112
14316
14316
14316
14316
14316
14316
14316
14316
34
318
16316
34
334
16316
1
334
16316
1
4
16316
114
4
16316
114
414
16316
112
414
16316
112
412
16316
34
312
18316
34
418
18316
1
418
18316
1
412
18316
114
412
18316
114
434
18316
112
434
18316
112
5
18316
34
334
20316
34
412
20316
1
412
20316
1
434
20316
114
434
20316
114
5
20316
112
5
20316
112
514
20316
34
4
22316
34
5
22316
1
5
22316
1
514
22316
114
514
22316
114
514
22316
112
514
22316
112
512
22316
34
412
24316
34
514
24316
1
514
24316
1
512
24316
114
512
24316
114
534
24316
112
534
24316
112
6
24316
434
34
512
1
512
1
534
114
534
114
6
112
6
112
614
14316
2
16316
234
inner diameter
wall thickness
length
18316
34
3
inner diameter
wall thickness
length
34
20316
312
inner diameter
wall thickness
length
34
22316
312
inner diameter
wall thickness
length
24316
34
334
34
See Fig. 6.
8. Keywords
F 994 86 (2001)
F 994 86 (2001)
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).