Installation instructions

6 Installation instructions

6.1 Installation of cabinet


Place the cabinet on a wall with an even foundation. It is recommended to place the cabinet in the user’s eye-
level.

UP
OP

160
260 Ø8
ø8

• Drill 4 pcs. Ø8, 50 mm depth, into the wall according to the above sketch.
• Put 4 pcs. S8 ZAK wall pins into the holes.
• Place the cabinet above the holes.
• Fasten the cabinet with 4 pcs. PH 5.5x50 tapping screws.

6.2 Electrical connections


There are 17 holes for installation of pg13.5-adapters in the bottom of the cabinet.
When the installation is concluded all unused holes must be blinded.
See chapter 10 for wiring diagrams.

17
All connected cables must conform to the current rules. Note the special requirements regarding
serving cables for agricultural construction. Funki assumes no responsibility for any damage in
connection with improperly used cables and misinstallation.

Make sure that supply voltage and frequency match the connected equipment before connecting
the system to the net.

Motors must be protected according to the current rules for connection of electric drive mecha-
nisms. Make sure that the setting of the protective motor switches match the declarations on the
motor type plates.

Before connecting the motors, check the sequential order of phases for the rotating direction of
the motors

The system must always be equipped with a main switch according to the current rules.