Evacuated Tube Collector ( ETC ) Solar Water Heater Technical Details ( Domestic systems )
Model Utility Number Number Number Back up Inner Inlet/ Outlet Outer Tank Max. Approx.Weight System Min.required Min. area
Points of persons of of Heater tank pipe size cover Insulation operating of one complete height from overhead tank reqd.
using hot Headers Evacuated (optional) of storage pressure system without the roof height from (NS x EW )
Water tubes tank of the water the roof
system Most advanced International
100 LPD 2 2-3 -- 15 2kw SS 304 1.9cm (3/4”) SS/Aluminium PUF 0.4 51 kg 1.1m 1.25m 1.75 m x 1.25 m
Stucco kg/cm 2
125 LPD 2 3-4 -- 19 2kw SS 304 1.9cm (3/4”) SS/Aluminium PUF 0.4 61 kg 1.1m 1.25m 1.75 m x 1.5 m
Stucco kg/cm 2
200 LPD 4 5-6 -- 30 2kw SS 304 1.9cm (3/4”) SS/Aluminium PUF 0.4 98 kg 1.1m 1.25m 1.75 m x 2.3 m
Stucco kg/cm 2
300 LPD 5 8-9 1 42 2 kw SS 304 1.9cm (3/4”) Aluminium PUF 0.4 152 kg 1.7 m 1.85 m 3.7 m x 4.2 m
Stucco kg/cm 2
500 LPD 8 14-15 2 76 4 kw SS 304 2.54 cm (1”) Aluminium PUF 0.4 282 kg 1.7 m 1.85 m 3.5 m x 7.5 m
(2kw+2kw) Stucco kg/cm 2

Evacuated Tube Collector ( ETC ) Solar Water Heater Technical Details ( Large Scale systems )
Model Utility Number Number Number Back up Inner Inlet / Outlet Outer Tank Max Approx. Approx. Approx. System Min. Min.area
Points of of of Heater tank pipe size Cover insulation operating Weight Weight Weight height required reqd.
persons headers evacuated (optional) of storage pressure of the of one of one from overhead (NSxEW)
using tubes tank of the storage header set complete the roof tank
hot system tank (one header system height
water without and 30 with water from the
water tubes) roof
without
water
1000 LPD 14 30 4-5 120-150 9 kw SS 304 2.54cm (1”) Aluminium PUF 0.4 60 kg 106 kg 1632 kg 1.75 m 1.9 m 4.0 m x 14 m
(4.5kw - Stucco kg/cm2
2Nos)
2000 LPD 28 60 8-10 240-300 9 kw SS 304 3.81cm Aluminium PUF 0.4 175 kg 106 kg 3375 kg 2.0 m 2.15 m 6.6 m x 14 m
Nos (4.5kw-2Nos) (1.5”) Stucco kg/cm2
3000 LPD 42 90 12-15 360-450 9 kw SS 304 3.81cm Aluminium PUF 0.4 184 kg 106 kg 4940 kg 2.1 m 2.25 m 9.2 m x 14 m
Nos (4.5kw-2Nos) (1.5”) Stucco kg/cm2
4000 LPD 56 120 16-20 480-600 13.5 kw SS 304 5.80 cm Aluminium PUF 0.4 219 Kg 106 kg 6579 kg 2.2 m 2.35 m 11.6 m x 14 m
Nos (4.5kw-3Nos) ( 2”) Stucco kg/cm2
5000 LPD 70 150 20-25 600-750 13.5 kw SS 304 6.35cm Aluminium PUF 0.4 272 Kg 106 kg 8162 kg 2.4 m 2.55 m 14 m x 14 m
Nos (4.5kw-3Nos) (2.5”) Stucco kg/cm2

* Pressurised models in ETC is also available

Superiority of Evacuated Tube Technology


Evacuated Tube Collector (ETC) Flat plate Collector (FPC)
1. Quick heat generation Slow heat generation
2. Heat absorbing surface is always perpendicular to the sun-rays because of the The collector fins and tubes being flat, the incident sun-rays will be at 90 degrees
cylindrical collector glass tube. Hence peak absorption always. only at noon. So the peak absorption is also only during this time.
3. Vacuum inside the collector tube reduces heat loss at night Heat loss will be more in collector panels at night.
4. Negligible scaling of tubes - can be cleaned manually (Inner dia 37 mm). Heavy scaling of copper tubes which cannot be cleaned manually as bore dia is
Consequent loss of efficiency is minimum. 12.50mm, causing substantial loss in the efficiency of the system.
5. Satisfactory performance in cold conditions. Performance falls significantly on cloudy and winter days
6. Increment in temperature from ambient temperature is 100c to 500c on clear sunny days. Increment in temperature from ambient temperature is 100c to 400c
7. Advanced technology at a competitive price Outdated technology, high price.
8. Less area required for installation Unit occupies huge area
9. Incase of collector tubes damage, tubes can be replaced individually. Entire glass has to be replaced in case of damage, high cost for replacement.
Authorised Distributors / Service Centres: NORTH ZONE: • Ghaziabad-1,
Ph: 0120-4108584 • Lucknow -20, Ph: 0522-40695237• New Delhi - 5, Ph: 011-
32921257 • New Delhi - 61, Ph: 011-2806158 • Gurgaon-17, Ph: 0124- 3244424
• Ludhiana, Ph: 0161-5016303, 4630030 • Chandigarh-2, Ph:0172-4640565. WEST
ZONE: • Goa -01, Ph: 2229827 • Goa-02, Ph: 2749694 • Jaipur, Ph: 0141-3 2 1 7 9 0 2 ,
Authorised DMA/Dealer: 0 9 4 6 0 4 7 3 6 3 3 • P u n e - 1 8 , P h : 0 2 0 - 2 7 4 2 1 6 0 5 , 3 2 5 4 9 5 7 9 • Nagpur-9,
Ph: 0712 -2743703, 2744232 • Navi Mumbai-400614, Ph: 022- 64519864. • Kolhapur-
3, Ph: 09822850645, 0231-2669608 • Solapur-7, Ph: 0217-2327380 • Nasik- 09,
Ph: 0253- 2394924, 2378984.• Nanded-1, Ph: 02462-651051 • Vadodara-10,
Ph: 0265-2630362, 6451274 • Ahmedabad-1, Ph: 079-22120888 • Navsari-24,
Ph: 02637-236951, 236952 • Rajkot-4, Ph: 0281- 2922500 • Udaipur - 1, Ph: 2423606,
2420277. EAST ZONE: • Bhubaneswar-6, Ph: 0674-2312885 • Cuttack-1, Ph: 0671
- 2624554 • Sambalpur-1, Ph: 0663-2532591 • Rourkela-1, Ph: 0661 -2510408
• Berhampur-3, Ph: 0680-3296594 • Balasore-1, Ph: 06782-263238.
• Jamshedpur-5, 0657- 6458488 • Ranchi-08, Ph: 08-0651-2231714 • Kolkata
-13, Ph: 033-22132137 • Raipur-4, Ph: 0771-2420228.• Indore - 1, Ph: 0731 -
4090637, 4096638. • Bhopal -16, Ph: 0755-4077804, 4044371. SOUTH ZONE:
• Ernakulam-17, Ph: 2339930 • Muvattupuzha-61, Ph: 2830777 • Kottayam-10,
Ph: 2572826• Pathanamthitta-71, Ph:2270903 • Alappuzha-13, Ph: 2232336

Solar Division: Palakkad Main Road,


, • Kollam-1, Ph:2764123 • Thiruvananthapuram-08, Ph: 2469764 • Thrissur-2,
Ph: 2388333 • Palakkad-7, Ph: 2573377 • Kozhikode-32, Ph: 6450450 •Tirur-
Solar Water Heater
1, Ph: 2427177• Kannur-12, Ph: 2706211 • Kanhangad-15, Ph: 2206938 • Coimbatore-2, Ph: 3292405 • Erode-1, Ph: 2277490 • Salem-
K.G. Chavadi, Coimbatore - 641105. 16, Ph: 2449873 • Vellore-1, Ph: 2235873 • Chennai-94, Ph: 23613399 • Chennai-84, Ph: 26612539 • Madurai-10, Ph: 4355689 • Trichy-18,
Ph: 0422-2656302, 2656553. Ph: 2741684 • Thanjavoor-1, Ph: 273083 • Karaikudi-1, Ph: 324422 • Tirunelveli-1, Ph: 2337903 • Kanyakumari-3, Ph: 227727 • Hosur -9, Ph:04344-
244373 • Tirupur -1, Ph: 0421-4322883 • Puducherry-1,Ph: 2224472 • Port Blair-1, Ph: 230173 • Bangalore-03, Ph: 23561155• Bangalore-16, OPTIONAL
Telefax: 0422-2656301. E-mail: mail@vguard.in Ph :25661857 • Bangalore-562 125, Ph : 27822955 • Mysore-21, Ph: 2494973 • Hassan-1, Ph: 08172-233321• Mangalore-4, Ph:0824- 4289270
Visit us at: www.vguard.in • Udupi-1, Ph: 2530500 • Shimoga-1, Ph:08182- 228326 • Hubli-23, Ph: 0836-2227302 • Davangare-4, Ph: 221222 • Belgaum-6, Ph: 0831-2463594
• Bijapur-1, Ph: 0852-650775 • Gulbarga-2, Ph: 08472-235123 • Bellary-3, Ph: 0839-2320690. • Secunderabad-80,Ph: 040-65946970.• Warangal-
Solar Water Heater
9, Ph: 0870-2554255 • Vijayawada-2, Ph: 0866-2435590 • Rajahmundry-3, Ph:0883-2438167 • Vishakapattanam-3, Ph: 0891-2568759 • Nellore-
1, Ph:0861-2332971 • Thirupathi-7, Ph: 0877-6571477 •Ananthapur-4,Ph:245247 • Kurnool-2, Ph:236691. • Available with all leading dealers.
Due to the continuous development & product improvement, the company reserves the right to change/ alter the specifications without anyprior notice Energy Saved is Energy Produced Conserve Energy... Protect Nature.

c m y k c m y k