You are on page 1of 6

Additional Info - Server Consolidation project

License Type for 16 Servers Physical That Need to Convert to Virtual Machine.

ITE SERVER LICENSE


M
1 COEAPP OPEN
2 COEDEV OPEN
3 COEPUB OPEN
4 ADSVR2 OPEN
5 DNSSVR2 OPEN
6 ILMUPS RedHat Ent Linux V4
7 MYASSET OEM
8 MYSPAMGUARD2 CentOS 5.1
9 OPENDEV CentOS 5.1
10 SKAN-APP-SVR1 OEM
11 SPKDB OEM
12 SPKDEV OEM
13 SPKWEB OEM
14 SPRK-SVR01 OEM
15 SYMPHONIX OPEN
16 WEBSVR OPEN

Bil Jenis Perisian Bilanga Tarikh Tamat


n Lesen

1. VMWare

a) vSphere 4 Enterprise (4 CPU) 1 15 Mei 2010

b) vSphere 4 Standard (2 CPU) 1 23 Mei 2011

c) vSphere 4 Standard (2 CPU) 1 23 Mei 2011

d) vSphere 4 Standard (2 CPU) 1 17 Mei 2010

2 vCenter Server 4 Standard 1 10 Jun 2011

Existing Storage Virtual Machine Servers


ESXSVR1 (VMSVR1)
ITE SERVER DIRECTORY FREE SPACE (GB) USED SPACE (GB) TOTAL SPACE (GB)
1. COEAPP2 C: 45.4 24.5 69.9
M
E: 115 54.2 169

2. COEPUB2 C: 17.2 52.7 69.9

E: 71.5 78.4 149

3. MAIL1 C: 172 77.4 249

4. MYASSET2 C: 43.8 23.1 67

5. SPKDB2 C: 56.5 13.4 69.9

D: 122 127 249

6. SPKWEB C: 27.5 42.4 69.9

D: 41.2 8.77 49.9

7. SQLSVR2 C: 46 23.9 70

E: 17.6 126 144

TOTAL STORAGE 1426.5

ESXSVR2 (VMSVR2)
ITE SERVER DIRECTORY FREE SPACE (GB) USED SPACE (GB) TOTAL SPACE (GB)
1 APPSVR 50
M OPEN SOURCE OPERATING SYSTEM

2 BBES C: 26.1 23.8 49.9

3 ENAZIRAN C: 42.8 7.09 49.9


ESXSVR2 (VMSVR2)
ITE SERVER DIRECTORY FREE SPACE (GB) USED SPACE (GB) TOTAL SPACE (GB)
4 FWSVR C: 42.5 57.4 99.9
M
E: 28.6 21.3 49.9

5 OLSDAP 20
OPEN SOURCE OPERATING SYSTEM

6 PINGAT C: 25.2 24.7 49.9

7 TRAVELLER C: 9.46 10.5 19.9

8 WINSUS C: 58.8 41.1 99.9

TOTAL STORAGE 489.3

ESXSVR3 (VMSVR3)
ITE SERVER DIRECTORY FREE SPACE (GB) USED SPACE (GB) TOTAL SPACE (GB)
1 ADSVR C: 9.13 10.3 19.5
M
E: 11.2 8.78 20

F: 23.9 4.35 28.2


ESXSVR3 (VMSVR3)
ITE SERVER DIRECTORY FREE SPACE (GB) USED SPACE (GB) TOTAL SPACE (GB)
2 BRIGHTMAIL 100
M OPEN SOURCE OPERATING SYSTEM

3 DNSSVR C: 2.81 7.18 9.99

D: 38.9 1 39.9

4 MAIL2 C: 178 71.2 249

5 PINGAT2 C: 25.2 24.7 49.9

6 PINGATDB C: 30.8 19.1 49.9

7 SAV2 C: 32.2 17.7 49.9

8 UPISDB 50

9 UPISPORTAL OPEN SOURCE OPERATING SYSTEM 50

10 WEBOPAC 50

11 WPSEJAHTERA C: 49.4 10.5 59.9

E: 99.6 0.4 99.9

TOTAL STORAGE 926.09


ESXSVR4 (VMSVR4)
ITE SERVER DIRECTORY FREE SPACE (GB) USED SPACE (GB) TOTAL SPACE (GB)
1 DMS C: 40.3 9.65 49.9
M
E: 99 0.99 99.9

2 ECRUDB 80

OPEN SOURCE OPERATING SYSTEM


3 ECRUPORTAL 80

4 KGBARU C: 34.4 15.5 49.9

5 LICSVR C: 45.9 4.01 49.9

6 NAGIOS C: 30.8 19.1 49.9

7 PINGATDB2 C: 30.2 19.7 49.9

8 TIMESVR 20
OPEN SOURCE OPERATING SYSTEM

9 VCENTER C: 39 10.9 49.9

11 WEBSVR C: 15 44.9 60

D: 76.4 63.5 139

11 WEBTAMS C: 33.4 16.5 49.9

D: 49.9 (72.5 MB) 49.9

TOTAL STORAGE 878.1

ESXSVR1 + ESXSVR2 + ESXSVR3 + ESXSVR4


( 1426.5 + 489.3 + 926.09 + 878.1 = 3719.99 GB )

EXISTING STORAGE VM SERVER = 3719.99 GB


*Terdapat LUN pada ESXSVR1
List of Processor for 16 Servers Physical That Need to Convert to Virtual Machine

Item Server Name Model Processor

1. COEAPP IBM xSeries 346 Intel Xeon 3.2 GHz (4 CPU)

2. COEDEV IBM xSeries 346 Intel Xeon 3.2 GHz (4 CPU)

3. COEPUB IBM xSeries 346 Intel Xeon 3.2 GHz (4 CPU)

4. ADSVR2 HP Proliant DL380G3 Intel Xeon 3.06 (2 CPU)

5. DNSSVR2 HP Proliant DL380G3 Intel Xeon 3.06 (2 CPU)

6. ILMUPS DELL PowerEdge 2950 Intel Xeon 3.0 GHz (Dual Core)

7. MYASSET HP Proliant DL140G3 Intel Xeon 2.33 GHz (2 CPU)

8. MYSPAMGUARD2 HP Proliant ML350G4p Intel Xeon 3.2 GHz (2 CPU)

9. OPENDEV HP Proliant ML350G4p Intel Xeon 3.2 GHz (2 CPU)

10. SKAN-APP-SVR1 DELL PowerEdge 2650 Intel Xeon 2.39 GHz (2 CPU)

11. SPKDB HP Proliant ML350G4 Intel Xeon 3.2 GHz (4 CPU)

12. SPKDEV HP Proliant ML350G4 Intel Xeon 3.2 GHz (4 CPU)

13. SPKWEB HP Proliant ML350G4 Intel Xeon 3.2 GHz (4 CPU)

14. SPRK-SVR01 HP Proliant ML350G4p Intel Xeon 3.2 GHz (2 CPU)

15. SYMPHONIX HP Proliant DL380G3 Intel Xeon 3.06 GHz (2 CPU)

16. WEBSVR HP Proliant ML570G2 Intel Xeon 3.00 GHz (4 CPU)

 Bilangan CPU di atas adalah berdasarkan kepada pemeriksaan melalui Windows (dxdiag)
 Maklumat Bilangan Soket Processor tidak dapat diperolehi oleh saya memandangkan untuk
melakukan pemeriksaan bilangan soket processor memerlukan kaedah yang rumit. Tuan boleh
hadir ke Kementerian ini nanti untuk berbincang mengenai bilangan soket processor server
tersebut.

You might also like