PRESENTATION ON

OVATION
FEATURES OF OVATION:
 AMS Intelligent Device Manager
 Ovation Plant Web Alerts

 Ovation Operator Workstation

 Intuitive Programming Tools

 Ovation Network

 Ovation Process Historian

 Ovation Security Features

 Connectivity
OVATION COMPONENTS:

 Network
 Controllers

 Input / Output Modules

 Relational Database

 Enterprise Integration

 Workstations

 Historians

 Report Servers
NETWORK FEATURES:
 Real time data transmission without loss , even during
plant upsets
 Fast 100Mbps Communication

 Interchangeable Fiber-optic and copper media with UTP,


Multi-mode Fiber, and single-mode fiber for network
architecture
TYPES OF NETWORKS

Network Speed Drops Points

W1 2 MB 254 16,383

W2 2 MB 254 32,000

W3 100 MB 254 2,00,000


CONTROLLER FEATURES:

 Provides Ultimate Flexibility through open Computing


Standards
 Executes Simple or complex modulating and sequential
control strategies
 Performs data acquisition functions and interfaces to
ovation network and I/O Subsystem
 Broadcast Value and status of each point in a drop at
appropriate frequency
I /O MODULE FEATURES:
 Provides low power consumption and heat dissipation.
 Feature standard DIN rail mounting for fast and easy
installation.
 I/O Module Consists of:
 Electronic module

 Personality module

 Terminal Block

• Electronic Modules:
Converts field signals into data and sends in to the controller
• Personality Module:

Characterizes the category of type of I/O and offers the


number of protection features.
• In an I/O Module both personality and Electronic module
should be same
 Module Numbering
 LeftBranch - Top to bottom
 Right Branch- Bottom to top
• Relay I/O Module Should be mixed with standard I/O
Modules
• Controller is connected to the remote nodes through Media
Attachment Unit(MAU) and Remote node Controller.
• MAU-Converts electrical signal in to Optical Signals.
• Remote Node Controller(RNC) interfaces controller and
Remote Modules.
• MAU and RNC are connected via Fiber Optic Cable.
• 1 MAU can connect 4 RNC.
Features UTP STP Coaxial Multi Single mode
Mode Fiber Fiber
Cost Low Low Moderate High High +
Installation Simple Simple Simple Differential Differential
Capacity 100Mbps 155Mbps 500Mbps 2Gbps 50Gbps

Distance 100meter 100meter 1Km 4km 30km

EMI N/R Poor Fair Excellent Excellent


CONTROLLER OCR-400:

 A Set of Controllers
Primary Controller
Partner Controller(Redundant)
 It is called as Compact Controller.
 Capability to originate 16,000 points.
 It uses Intel Pentium processor.
 Speed for the processor is 400MHz.
 Capable of simultaneously executing as many as five process control tasks at loop
speed ranging from 10 milliseconds to 30 seconds
 Each control task is comprised of I/O process point input scan, the control scheme
execution followed by output scan
1. One scan task -1S task
2.Second scan task -100mS task
3.Three, Four ,Five - User Selectable
 Control Scheme:
 Building control Sheets with an extensive set of algorithms.
 Controller can provide execution of 6000 Control Sheets.
• Controller Redundancy:
Ovation Network Interface
Functional Processor, Memory and Network Controller

Processor Power Supply

I/O Interface

Input power Feed

I/O Power Supply

Auxiliary power Supply

Remote I/O Communication Media


Controller Specification:
ITEM CAPABILITY
Bus Structure PCI Standard
Originated Points 16,000
Process Control Task Up to 5 with different execution
rate, two defined and three user
definable

Control Task Execution Rate Every 10ms to 30sec in 10ms


increments

Processor Intel
Memory 128MB Flash &128MB RAM
NIC Ports 4*10/100 MB Ethernet
Power 24V DC 40W
CONTROLLER I/O CAPABILITIES:
ITEM CAPABILITY
Local Ovation I/O 2 Set of up to 8 independent
branches of 8 modules per
branch for a total of 128
modules
Direct wired local I/O Analog =1024 or
Maximums Digital or SOE=2048
Remote Ovation I/O Up to 8 nodes of 64 modules

Maximum number of remote 8 nodes per ovation controller


nodes
Maximum number of I/O 64(8 branches with 8 modules
Modules per remote node for each branch)
Maximum number of I/O 512(8 nodes,8 branches for
Modules per controller each node,8 modules for each
branch)
Maximum number of I/O 1024
Modules per controller
TYPES OF I/O MODULES:
 8 Channels Analog input
 8 channel HART Analog input

 8 channel Thermocouple input

 8 channel RTD input

 4 channel Analog output

 16 channel Digital input

 16 channel control input

 16 channel Digital output

 2 channel Pulse Accumulator/Counter

 16 channel Sequence of Events


I/O MODULES ADDRESSING
 D.N.B.S
 D-Device number
 1-Local Ovation
 2-Local Ovation

 3-Local Q-Line

 4-Can be

 Remote Ovation
 Remote Q-Line
 Local Q-Line
• 5-9 – Third Party Devices
 N-Node number(used for remote 1-8)
 B-Branch number
 S-Slot number
ANALOG I/O MODULES:
 Individually Isolated
 Low Power Requirements

 Analog I/O Modules include:


 13-bit AnalogInput
 14-bit Analog Input
 RTD Input
 Analog Output
• Locally powered and Field powered transmitters can
be connected in a same module
13-bit Analog Input:
 Individually isolated inputs
 8 channels per module

 Individual A/D Converter Per channel

 13 bit resolution , including sign

 10 updates per second under normal conditions

14-bit Analog Input:

 8 channels per module


 Consists of 2 groups of personality and electronic modules

providing current signal of 4-20 mA and voltage signal


of +/- 1V
 20 updates per second under normal conditions
DIGITAL I/O MODULES:
 16 channels per module
 Single ended or differential inputs

 Handling AC or DC inputs ranging from 24V to 125V

Sequence of Events:
 16 channels per module

 Supports digital, single ended or differential inputs

 Ranges include
24 VAC/VDC Single ended/Differential ended
48 VAC/VDC Single ended/Differential ended
125 VAC/VDC Single ended/Differential ended
 1/8 m sec event time tag resolution with in a controller
OCR400 PROCESSOR AND I/O
INTERFACE MODULES

NETWORK INTERFACE PORTS:


N1- Other Additional Interfaces(eg : Allen Bradlely)
N2- Single Attached Network Interfaces
N3- Dual Attached Network Interfaces
N4- Dedicated Control Synchronization
I/O INTERFACE MODULES:
R3- Supports 4 nodes of remote or 4 nodes of remote Q-Line
R4- Supports 4 nodes of remote or 4 nodes of remote Q-Line
Q5- Supports 4 create(1 node) local Q-line
SPECIAL MODULES:
 Link Controller Modules
Programming Port
 Pulse Accumulator
 Counting of pulses
 Valve Positioner
 Linear Variable Differential Transformer
 Speed Detector
HISTORIAN ARCHITECTURE
 Modular Design:
 Historian functions separated in to independent software subsystem.
 Each subsystem performs unique function like scanning , collecting,
storing , retrieving or displaying historical data.
• Client /server Architecture:
 Server portion runs on historian. Server collects the
data from ovation network, send the data to archive
storage and responds to retrieval requests.
 Client application program runs on operator or
engineer work station. It provides the functions to
display ,print or save the data collected by server.
HISTORICAL SCANNING AND COLLECTING:
 Scans or collects six type of historical data
 Real time point values and statuses

 Laboratory data

 High speed data

 Alarm messages

 Operator action messages

 Sequence of events messages

 Report files
POINT HISTORY:
 Main History:
 Continually collects process point data
 Scan up to 20,000 data points

 Multiple scan frequency defined by the user on 1sec increments

 Collection based on dead band Selection and change in point status

 Long term storage Memory:


• Collects and store process point data and retrieves data based on user request
• Scans 600 user definable points and stores the value in online storage value

• Collection based on dead band Selection and change in point status

•Dedicated storage allows information to remain online for long time


EVENT HISTORY:
 Events such as plant trips or equipment startup can be
saved.
 Once event is activated 500 user defined points are
collected at 100 ms rate and scheduled for archive.
 Scans and collects 1hr worth of data.

 OWS or EWS can generate trends or reviews of the


values collected in the event history.
POINT GROUP HISTORY:
 Itis similar to the event history capable to define up to
5 historical groups of 20 points each.
 Scan and collect information on points with in the
predefined sets at a 100ms rate for an hour.
 Collection of group data associated with common
control functions
Event History Point group
Scan Rate 100ms 100ms
Points Scanned 500 points Up to 5 group of 20
each
Collection rate 100ms 100ms
LABORATORY DATA
 Unique data collection method for handling point data ,
i.e. not acquired in real time.
 Up to 1000 individual points collected via manual entry
or by communication with external device
 Stored in to historical archive for use in trends , reports
and other retrieval functions
MESSAGE HISTORY

 Alarm History
 Receives and stores alarm sent by alarm logging drop
 Allows an operator or engineer to display , print or save to a file the
list of alarms collected
 Capability to filter the alarm list based on factors such as
 Point name
 Time period or

 Originating period.
OPERATOR EVENT HISTORY
 Records operator actions received from OWS or
ovation controller
 Data Retrieval up on client application request

 Filtering is done through time period originating drop


or event type
File History
 Saves and archive operator shift diary output and
report generator output as data files in the historian.
 File history client interface used to retrieve these data
from historian by OWS or EWS
SEQUENCE OF EVENT HISTORY

 Collects SOE data from controller ,sorts in to a list


and searches the “first-out” events.
 Interface allows the operator to view the SOE report
and filter it based on tag name , controller or “first-
out” point
 Appropriate SOE I/O modules are equipped to
perform function.
HISTORICAL DATA STORAGE AND RETRIEVAL
 Historical data scanned and collected is stored for future
retrievals
 Historian utilizes 3 storage areas
 Primary storage
 Secondary Storage

 Long term Storage

• Primary Storage
• Stores most recently collected data
• Includes information from main event point long term
histories.
• Information from primary storage transferred to secondary
storage at user selectable time.
• It allows Primary storage to clear and available for
collection of the next time period data
SECONDARY STORAGE
 Maintains a period of historical files on hard disk.
 Automatic copy of all data placed in secondary storage
to long-term storage provides redundancy
 Storage limits are determined by capacity of hard
drive(s) and size of files.
LONG TERM STORAGE
 Optical disk storage is available to store up to 5.2
gigabytes
 Disk size varies from 80GB to 400GB

Storage Summary

Type Minimum Size


Primary Hard Drive 2GB
Secondary Hard Drive 4GB+
Long term Optical Disk Drive 5.2GB/disk
Drive Jukeboxes 80-330GB
ARCHIVE MANAGER
 3 functions
 Moves Historical files
 Manages retrieval functions

 Manages redundancy and recovery functions

 Moving Historical files


Responsible for moving historical files from one
storage place to another
Files are automatically moved from primary to

secondary and from secondary to long term storage


Deletes oldest secondary files when permanently

placed in long term storage


MANAGING DATA RETRIEVALS
 Automatically locates stored historical data for
retrievals
 It can find information stored in the hard drive when
user enters the requested time.
 Automatic retrieval of information within an optical
jukebox is a unique function
Redundancy and Recovery
 Consist of two separate identical sets of computer
hardware
 Concurrent redundancy scheme in primary and
partner historians
RETRIEVAL HISTORICAL DATA
 Historical Trends
 Utilize information collected in the data histories
 Up to 8 user definable points can be trended.
 Time period can be determined by the user
 Time periods can be defined in 3 ways
 Start and End times
 End time with specified intervals

 Start time with specified intervals


Point Review
•Tabular method of displaying historical information

• Point group Review

•Allows operator to display , print or save to a file the


historical data collected from the point group history.
ALARM REVIEW
• Allows operator to display , print or save to a file the
historical data collected from the alarm history.
Operator Event History
 List of events filters the list of operator events by time period
originating drops or events
SOE Review
 Allows the operator to view SOE report generated
by SOE history.
SQL Queries
 Historical data may be recalled in response to standard SQL
data queries