CASE HISTORY

V E R T I C A L W AT E R P U M P S
– W H AT ’ S H A P P E N I N G D O W N T H E H O L E ?

Turning Hard-to-Reach Data into More Profit for Saudi Aramco

Malcolm K. Graham Failures of submerged vertical pumps In today’s economic climate, indus-
Engineering Consultant
Dynamic Analysis Unit
often occur without due warning tries are pressured to operate their
Consulting Services Department from the installed sensors and mon- equipment longer and at improved
Saudi Aramco itors. The reason is the lack of efficiencies, while maintaining safe
e-mail: grahammk@aramco.com.sa
transducers mounted where they and reliable operation. This can be
can reliably sense the condition of achieved in part by monitoring and
Barry Nurcombe, CEng
Senior Applications Design Engineer the pump, down in the hole! Since trending of parameters such as
Bently Nevada UK Ltd. there are no industrial standards vibration, lube oil condition, per-
e-mail: barryh.nurcombe@bently.com that require sensors at the bottom formance, exhaust gas analysis, etc.
of the pump, regardless of the power Vibration monitoring is probably
rating, the sensors are most often the most important tool in these
mounted on the motor, some dis- programs and has become accepted
tance from the pump. In the past, and proven worldwide in various
reduced efficiency and pump failure industries. With the exception of
have not proven to be enough incentive submerged vertical pumps, vibra-
for operators to properly instrument tion monitoring is a requirement of
the system. Saudi Aramco and industry stan-
dards for all rotating equipment.
ISO 10816-1 RECOMMENDATIONS FOR MEASURING POINTS This article addresses the vibration
monitoring of submerged vertical
FOR VERTICAL MACHINE SETS. pumps that is now possible due to
recent advancements in installation
technology pioneered by Bently
Nevada.

Vertical Pump Monitoring


The monitoring methodologies in
the standard, Mechanical vibration
FIG. 1
– Evaluation of machine vibration
by measurements on non-rotating
parts, ISO 10816-1: 1995, recommend
measuring at points that “signifi-

?
cantly respond to the dynamic forces
Can we
know what and characterize the overall vibration
happens of the machine.” However, most
down the end-users consider it to be unrea-
hole?
sonable to monitor every cutlass
Bearing rubber bearing on the riser tube,
Condition? and 10816-3: 1998 (E) recognizes
Cavitation? the practical considerations that

4 ORBIT 1Q03
CASE HISTORY

cause the points to usually be on the need for permanent online “tail-wagging-the-dog” method-
“exposed parts of the machine systems for critical units or a portable ology has limitations; the signal will
that are normally accessible.” data collector (PDC) on small pumps be attenuated by the different machine
In fact, the measuring points sug- or multi-spare installations. Whether components between the pump and
gested by 10816-1 (Figure 1) are the data is collected by means of a the motor and will be overlaid with
shown on only the bearing housings PDC, such as Bently Nevada’s the signal of the motor.
at the top of the machine; because Snaphot ™ for Windows ® CE, or For example, the detection of cav-
the pump bowl/impeller region is permanent monitoring and man- itation can only be carried out in
not easily accessible, it is omitted. agement systems, there are the impeller/pump bowl region.
Therefore, many users of vertical methodologies available to assist Farther up the riser tube, flow-gen-
pumps are unaware of the machinery you in taking data from those pre- erated noise coming from the
information that is available “down viously inaccessible places. intermediate bearings adds to the
the hole” and ignore, for what used
to be justifiable economic reasons,
what turns out to be an essential
source of data. In the case of ver-
tical cooling water pumps, where TO INSTRUMENTATION
JUNCTION BOX
the intake, pump bowl, impeller(s), 1/2" NPT CONDUIT ASSY

and bearings that Bently Nevada P/N 14847-12 (3 PLACES)

DRILL THROUGH AND


and ISO strongly advocate moni- TAP EACH SIDE 1/2" -

toring, are all under water, the data 14 NPT POSITION TO BEST
ADVANTAGE AND
must be collected by other than the ACCESS (3 PLACES)

usual methods.
While the ISO 10816-1 standard
is only concerned with measure-
3 EQUALLY SPACED
ments taken on nonrotating parts STAINLESS STEEL 'BANDIT'
PUMP BOWL BEARING VELOMITOR

(OR EQUIV.) STRAPS TO


(the casing), there are good reasons LOCATE PIPE CLAMPS
ON NORTH & EAST SIDE, DRILL AND TAP
MID POINT OF FLANGE 1/2" - 14 BSPP x 25 mm
to use proximity measurements of NORTH TRANSDUCER
FULL THREAD DEPTH (2 PLACES)

CONDUIT SUPPORT PLATE (BY OTHERS)


the shaft. For example, it is impos- SHOWN OUT OF
POSITION FOR CLARITY ATTACHED TO LIFTING POINTS. DUE TO
EPOXY SURFACE TREATMENT, NO
sible to determine the amount of DRILLING OF PUMP IS PERMITTED.

wear on the journal bearing caused


by suspended particulate matter by 1/2" O/DIA
STAINLESS STEEL PIPE
using case-mounted transducers
SUCTION BELL BEARING VELOMITOR
alone.
ON EAST SIDE ONLY, DRILL AND TAP MID
No matter which transducer you POINT OF FLANGE 1/2" - 14 BSPP x 25 mm
FULL THREAD DEPTH (1 PLACE)
select to provide the data needed to
manage your machine, Bently Nevada
PART SECTION THROUGH CIRCULATING WATER PUMP | FIG. 2
has designed an effective, reliable
installation package that simplifies
the process, reduces costs, and eco-
nomically justifies monitoring Information Is Missing or cavitation signal and confuses the
machinery that, up to now, has been Attenuated diagnosis. Since higher frequency
pumping some of your profits down There are certain conditions and signals attenuate faster than lower
the drain. configurations where the pump frequency signals, the data may
The machinery management regime vibration data can be picked up at not even reach the transducers
selected by the user will dictate the top of the motor. However, this (Figure 6).

1Q03 ORBIT 5
CASE HISTORY

Results from several installations THE TRANSDUCER MAY REQUIRE A CUSTOM-ENGINEERED ENCLOSURE
have shown that bearing and impeller
condition data is readily available protection package and modifica-
to transducers installed under water, tions are required to make a successful
close to the source of the data. installation. The proximity probe
has to be packaged in a watertight
Why Would This Data Be
outer casing that includes a ceramic
Needed?
cap. This cap provides a nonmetallic
In order for a pump to be main- window that prevents the erosion
tained at its optimum performance, of the probe tip. The thickness of
regular inspection is recommended. the cap, 0.25 to 0.50 mm dependent
There may well be indicators down- on the transducer, reduces the effective
stream of the pump that can show linear range of the transducer.
if the pressure or flow is below the The reduction of linear range means FIG. 3
required norm; these, if trended, that less wear can be detected. With
will give an indication that the pump the 5 mm 3300 XL package, the Installation Pitfalls
should be withdrawn from service thickness of the ceramic tip reduces
before unacceptable performance While the installation of monitoring
the range for diametral wear allowance transducers on the submerged
or failure occurs. The vibration data to 1.5 mm or less. It may well be
can be used to indicate the mechanical part of a vertical pump is relatively
appropriate to use the 11 mm 3300 straightforward, there are several
condition of the submerged bearings, XL probe, which offers a diametral
what parts might need to be replaced, important points that need attention:
wear allowance of up to 3.8 mm. In
and an appropriate maintenance both cases, the probe setup is critical SAFETY. Access to the submerged part
schedule that would minimize the because the thickness of the end of the pump is difficult and can be
cost of downtime. cap, while it decreases the physical dangerous. Ensure that appropriate
The removal of the submerged section range of the probe, does not lower safety measures are in place before
of a large vertical pump requires a the OK limit in the monitor. It is entering the intake pit.
great deal of preparatory work and therefore possible for the shaft to TURBULENCE. The areas surrounding
the use of heavy mobile cranes. In contact the ceramic tip before this the pump bowl and intake are subject
some cases, the high cost of crane limit is reached. If this can occur, to high turbulence, with significant
hire has been a deciding factor in then a modification to the monitor force being generated by the swirling
the decision to instrument the sub- may be required. water. The transducer and the conduit
merged section of the pumps; the Mechanical modifications to the must be securely attached to the
cost of instrumentation and mon- shaft and casing will also be signif- surface, and the conduit attached
itoring is typically less than the icant; for example, a probe target to the pump body at frequent intervals.
charge to hire a heavy crane for one ring, usually Inconel 625, must be If the components that are torn
week. With monitoring installed, attached to the shaft to minimize off the pump by the turbulence
the decision to lift the pump for corrosion of the track that the probe are ingested, they will damage the
maintenance can be based on real views. Where the probe cable has impeller.
data rather than on guesswork. to pass through the pump waterways, GALVANIC CORROSION. Some materials
the conduit pipe for the probe cable may actually promote corrosion.
Considerations for Bearing
should be attached to the leading Choose the transducer housing and
Wear Monitoring edge of fixed spokes or the cable the conduit materials carefully to
When XY proximity probes are carried in drillings within these webs. inhibit or prevent corrosion. They
installed to monitor pump bearing Secure methods of attachment are must be compatible with the mate-
vibration and wear, a special probe mandatory. rials found on the pump body and

6 ORBIT 1Q03
CASE HISTORY

in the intake pit. Sacrificial anode attached to the pump body, then imity probes and restricted access
blocks are particularly encouraged covered with layers of glass fibre and installations have made proactive
for seawater intake pumps. epoxy resin. While this successfully management of a wider range of
P R OT E C T I O N O F E L E C T R O N I C S. Water protected the transducer, it elimi- pumps and pump applications eco-
and electronics do not mix well. nated the ability to carr y out nomically feasible.
Ensure that the transducer is properly maintenance.
protected against ingress of water The UK Application Engineering Saudi Aramco Trial Results
that would lead to premature failure. Department then adopted tech- UK Applications Engineering pro-
nology used on submarines: namely, vided these custom transducer
COATINGS. Many pump intakes, bowls,
placing the electronics in a sturdy assemblies to Saudi Aramco for a
and riser tubes are treated with special
housing completely filled with water- trial installation on six seawater
corrosion-inhibiting coatings. Con-
repellent grease. The 21128 Velocity intake cooling pumps at the Ras
siderable care must be taken to repair
Housing was modified by adding Tanura Refinery on the Arabian
and seal this coating when drilling
a pressurized grease fitting and sealing Gulf Coast. The year-long study
through the metal below water level.
the exit with a 43501 Cable Seal was tasked with establishing solid
WITHDRAWAL OBSTRUCTION. The pump
Assembly (Figure 4). These modi- evidence that the dynamic behavior
bowl may not have much clearance of the pump is not documented
fications to existing hardware and
when it is inserted in or withdrawn by the data from transducers on the
the new package designs for prox-
from the foundation. The trans-
ducer may require a custom-engineered
enclosure, such as the one in Figure
3, to keep it from interfering with
the foundation.
WAKE TURBULENCE. Any conduit passing FITTINGS
across the intake of the bearing will CONDUIT & STAINLESS STEEL

cause a wake. This wake will give


rise to cavitation at the impeller, LOW PRESSURE CABLE SEAL
increasing the risk of erosion. Keep P/N 43501-01-00-01
PUNCH GROMMET TO SUIT
the conduit in line with struts or VELOMITOR CABLE

webs to prevent turbulence.


1/2" - 14 NPT MODIFIED 21128
EROSION. If the passage of particulate ENTRY THREAD VELOCITY HOUSING
matter through the pump erodes
VELOMITOR
the shaft, it will erode the probe tip, PIEZO-VELOCITY
TRANSDUCER
causing failure. Therefore, it is
important to protect and package LOCK NUT
the probe with erosion-resistant VELOMITOR
EXTENSION
materials. CABLE

Design and Development of a


Reliable Installation Package
Over the past 8 years, the engineers
in the U.S. Design and Installation MOUNTING
THREAD
Services and BNUK Applications
Design departments have designed
GREASE NIPPLE
and installed several vertical pump HOUSING PACKED WITH SILICONE
BASED WATER REPELANT GREASE
monitoring systems. In early trials,
a standard Velomitor® sensor was DETAIL OF UNDERWATER VELOMITOR HOUSING | FIG. 4

1Q03 ORBIT 7
CASE HISTORY

TO GAIN THE FULL ADVANTAGE OF THE MACHINERY MANAGEMENT PROCESS, THE UNDERWATER
SECTION OF VERTICAL PUMPS SHOULD BE MONITORED.

motors. A second task was to demon-


strate instrumentation reliability.
Two additional transducers were
mounted on the bottom of the mixed-
flow, 5-vane seawater pump (Figure
5), in line with the original trans-
EXISTING ducers on the motor. Signals were
TRANSDUCERS
routed to a four-channel monitor
with outputs for each sensor. Data
was collected on a monthly basis
MOTOR with a two-channel portable spectrum
and time domain analyzer.
The frequency and time domain
data (Figure 6) collected by Aramco
shows a clear difference in readings
taken from the sensors at the bottom
of the pump and the top of the
MONITOR motor.
DISCHARGE SUCTION The pump data shows a high level
of 1/2X component, especially in
the in-line direction. This signal is
highly attenuated in the motor data
from the corresponding in-line
direction transducer. The signal
components around 340 Hz, thought
to be associated with cavitation, are
completely absent from the signals
PUMP IMPELLER from the motor transducers.
CASING The Ras Tanura trials successfully
demonstrated the effectiveness of
the probes and the reliability of the
instrumentation in adverse condi-
tions. As a result, the Aramco engineers
recommended installation of sensors
at the bottom of submerged vertical
pumps. The next revision to Saudi
PROPOSED ADDITIONAL
Aramco centrifugal pump standard,
TRANSDUCERS
31-SAMSS-004, will include the
FIG. 5
monitoring requirement for open
pit applications. This is expected to
play a pivotal role in eliminating

8 ORBIT 1Q03
CASE HISTORY

many pump failures that came The main cooling water pumps nearly as critical as the main process
without due warning. (CWP) were fitted with the iden- or generating equipment. With
tical transducer housing used on demands for increased profitability,
SEC Follows Lead of Saudi the Aramco pilot project. However, the economic justification for mon-
Aramco the auxiliary CWP units, which itoring this machinery also increases.
Many customers follow standards must pass through a smaller foun- To gain the full advantage of the
set by others in their region. In 1999, dation ring, required custom housings. machinery management process,
the Saudi Electric Company, SEC, Under the supervision of BNUK’s the underwater section of vertical
specified that ten vertical seawater Applications Engineering, the under- pumps should be monitored. The
pumps for the new Ghazlan II Power water Velomitor ® housings were reliability and effectiveness of the
Plant were to be fitted with under- installed during 2001 as part of the monitoring package designed and
water monitoring. erection program. developed by Bently Nevada allows
Bently Nevada UK worked closely more machines to contribute pos-
with the design and project engi- Summary itively to the profitability of the
neers of the pump manufacturer, When the functions of the larger plant.
Weir Pumps of Glasgow, in order auxiliary machines in manufacturing For more information on this topic, contact
to reduce the impact on the man- and generation facilities are analysed, your nearest Bently Nevada Sales or Service
ufacturing and supply schedules. some machines will be found to be Professional.

1 1

Pump Transv O-Pk = 0.53 Pump In-Line O-Pk = 0.88


VELOCITY (IPS)

0 0

-1 -1
0.000 ms 399.609 ms 0.000 ms 399.609 ms

1 1
VELOCITY (IPS)

Motor Transv O-Pk = 0.55 Motor In-Line O-Pk = 0.26

0 0

-1 -1
0.000 ms 399.609ns 0.000 ms 399.609 ms

0.2 0.2
VELOCITY (IPS, Pk)

Pump Transv .23 10Hz Pump In-Line

.21 20 Hz

0.1 0.1
.07 10 Hz
.05 337 Hz
.075 20 Hz
.025 340 Hz

0 0
0.00 Hz 1.00 kHz 0.00 Hz 1.00 kHz

0.2 0.2
VELOCITY (IPS, Pk)

.32 20Hz
Motor Transv Motor In-Line

0.1 .06 10 Hz 0.1


.086 20Hz

0 0
0.00 Hz 1.00 kHz 0.00 Hz 1.00 kHz

FIG. 6

1Q03 ORBIT 9