8 Conditioning
The most common method to condition the felt is the oscillating High Pressure shower with Uhle box. The recommendation for pressure is: New felt, new TMO => 812 bar (116..174 PSI) After few days => 12 20 bar (174 290 PSI) Shock wash (short time) => 35 bar (500 PSI) NOTE! For the seam felts and endless felts with mono yarn base (=non twisted yarns), use slightly lower pressure. Recommendation max. 17 bar (250 PSI).
SOILING TYPE
0-fibre Resin and resin sizes Carbonate and aluminium salts Insoluble fillers e.g. clay, talk and titanium dioxide
CLEANING METHOD
High pressure shower Alkaline wash Acid wash
High pressure shower Neutral or slightly alkaline detergent with dispersion agent e.g. polyphosphate Solvent wash
-1-
PMC/PRESSING/mb 16.08.2007
PRESS FELTS
The standard oscillating High Pressure shower has 1,0mm (0.39) nozzles, the distance between the nozzles about 25cm (10) and the stroke 2 x nozzle distance just in case to cover possible plugged nozzle
-2PMC/PRESSING/mb 16.08.2007