100/1
CAVICEL
When talking about safety, a particular care must be paid to your interlocutor. When you then have to choose products that must safeguard systems and human lives, you have to make sure that your choice is the right one. The cables, for instance, that quite often cannot be seen, being hidden in walls or below the floor, but run for kilometres around us, must be chosen by a company you trust. Cavicel is present onto the market with a wide range of products, including the fire resistant cables FIRECEL that are installed in over 30 countries. Buildings, skyscrapers, public buildings, chemical and petrochemical plants, undergrounds, manifold applications that have a common denominator: they require a safe use of cables. When selecting cables that should guarantee specific performances in case of fire, it is necessary to choose a reliable company, with a long experience and careful to technology evolution. A reliable company, having a long experience that allows to gain the market trust.
Why CAVICEL
We have a long experience in designing and manufacturing special cables for over 50 years, and we have always worked closed to our customers to understand the real needs. Our cables installed in more than 50 countries say that we have the right knowledge and experience in approaching the market. We know the problems that a fire could cause to the cables, in terms of both signal interruption and fume emission that could prevent the evacuation or the rescue. There are a lot of problems to handle, we know, and this is why we work together with our customers to deepen all the problems. The right Partner is important to CAVICEL and this is why we put our experience at customers disposal.
CAVICEL
Where CAVICEL
Our cables are installed in the following countries: Algeria, Austria, Bangladesh, Belgium, Brunei, Bulgaria, Cyprus, Czech Republic, Denmark, Egypt, Estonia, Finland, France, Germany, Greece, Holland, Hong Kong, Hungary, India, Indonesia, Iran, Ireland, Italy, Japan, Jordan, Kuwait, Lebanon, Luxembourg, Malaysia, Maldive, Malta, Nigeria, Oman, Pakistan, Philippines, Poland, Portugal, Qatar, Romania, San Marino, Saudi Arabia, Singapore, Spain, Sudan, Sweden, Syria, Taiwan, Turkey, United Arab Emirates, United Kingdom, Usa, Venezuela, Vietnam, Yemen. Many destinations, but only one origin: Italy
Total Quality
Quality means different things to different people. Quality is not only our approved Quality System according to ISO 9001 by CSQ Italy and LPCB UK. Quality is not only our full equipped test laboratory to certified required characteristics of cables. For CAVICEL Quality simply means to satisfy customers not only supplying them the required products, but working together in a professional way to create a long lasting successfully relationship. Our growth and success stem from the quality of our promise and the certainty of delivering on promise. Quality also means respect for the environment and this is why Cavicel is now ISO 14001 certified.
Our Value
We are cable manufacturer, but we do not only supply cables. We grant the satisfaction of the right solution in cable application. And this means to have fully evaluated all customers requirements, not only in term of cable performance, but in term of service, knowledge, reliability in order to assure the best value for the customer. We try to understand our partners situation and criticality. Than we just create a cable which lets your value flow free. This is CAVICEL: Conducting Value.
Conductors
Conductors can generally be according to EN 60288: class 1 solid class 2 stranded class 5 flexible
Type of conductors are chosen according to electrical characteristics, required flexibility, type of connection systems or specific installation conditions, for example: in presence of vibration or movement or reduced bending radius is preferable class 5 flexible conductor, class 1 solid conductor is preferable for permanent installation, crimping termination, in presence of corrosive atmosphere, high temperature or to facilitate the soldering is preferable tinned conductor.
Cabling
Fire resistant cables generally can be laid-up in concentric construction and in pairs. Twisting is important to reduce noise in circuits and also the lay of twist in some constructions must be carefully considered.
Screening
Screens are often used in instrumentation cables to prevent or reduce possible interference in cables that can be caused by the following reasons: Cross-talk from adjacent pairs or triples; Interference induced by external source such as electrical equipments, machinery, power line. The most popular screen is: Aluminium/polyester tape with a tinned copper drain wire or earth conductor Following screens can also been used, when required: Copper/polyester tape with a tinned copper drain wire, for a better screen effect Bare copper braid for electromagnetic interference or when the cable is subject to movements
Aluminium/polyester or copper/polyester tapes normally have a total thickness from 25 to 100 m, according to standards and are wrapped with an overlap >125% to assure a full coverage even in case of bending. In continuous contact with metallic side there could be an earth tinned conductor, same cross section of the other cores, or a drain wire, normally tinned copper, 0.5 sqmm, stranded or solid, according to cable specifications. Copper braid normally has a coverage from 80% to 95%. This type of screen presents a lower electrical resistance, a very good protection also to electromagnetic noises and a higher mechanical resistance compared to aluminium/polyester tape. It is suitable for mobile applications.
Armouring
Metallic armour are used when cables have to be installed direct buried, or if mechanical protection is required. Following points must be considered: Required tensile load Expected pressure on cable during service Protection against rodent Protection against accidental damage Minimum required bending radius. SWA: single layer of galvanized steel wires, with diameters according to relevant standards, coverage min. 90%. This armour assures a very good mechanical protection and tensile strength. An additional counterspiral tape increases solidity, if required. GSWB: galvanized steel wire braid, diameter of wire: 0.20 - 0.25 - 0.30 - 0.40 mm, with coverage of >80%. It assures a good mechanical resistance, allowing a lower bending radius compared to other armour. It is preferable when there is movement or vibration. For special application is possible to use stainless steel, tinned copper or special alloy wires.
Sheath
To optimize the behaviour in case of fire, best sheath is made of LSZH (Lows Smoke Zero Halogen) materials since, thanks to that, fire would not be propagated, toxic or corrosive gases would not be developed and a minimum quantity of white fumes are emitted. Other materials can obviously be used in case of specific installation requirements, such as: PVC, for example, where a higher resistance to oils and chemicals is required (this material contains halogens, so it emits acid gas and smoke). PE, when a higher resistance to water and moisture is required (this material is no anti-flame, though).
Standards at a glance
A higher and higher care is paid towards safety in many places and environments in general. Fire is considered one of the most frequent cause of disasters and human lives loss. The standards have tried more and more to face this problem under various aspects. Over the last few years, particularly, both national (BS, DIN, CEI) and international (EN, IEC) standards have gone through a remarkable evolution. The evolution, though, is so fast that it is difficult to always have an updated picture. The purpose of this section is therefore to provide an overview on how the standards have faced the definition, the choice and the installation of the electric cables concerning the fire risks. Reference is also made to outdated standards since they are still present in many specifications.
Fire resistance
Fire resistance means that the cable or the installation where the cable is installed is capable to continue to operate even in case of fire for a specific period of time (from 30 to 180 minutes). To be more precise, it is possible to have two different definitions: Circuit Integrity (or Insulation Integrity) which indicates tests exclusively referred to cables; System Circuit Integrity is referred to tests on cables and systems (ladder, cable tray, clamps). In some countries, such as Germany or Belgium, the first characteristics (Circuit Integrity) is often indicated by an abbreviation (FE180 in case the test lasts 180 min) and the second one (System Circuit Integrity) by the abbreviations E30, E60, E90 that indicate the cable resistance for 30, 60 and 90 minutes according to a specific test and with different installation systems.
Standards at a glance
Smoke Density
Fire resistance
10
Standards at a glance
Behaviour to the fire of the electric cables
Constructive standards
BS 7629-1:2008 - Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. Multicore and multipair cables. This standard includes the currently most common cables onto the market of the fire resistant cables. Those cables are used in fire alarm and emergency lighting applications. They have a rated voltage of 300/500 V. Generally, the cables are particularly flexible and easy to be installed. These standards require that the cables get through the fire resistance tests prescribed by BS 6387 standards. BS 7846:2009 - Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification. This standard refers to the armoured cables with rated voltage 600/1000 V. The circuit integrity performance under fire conditions is assessed on the basis of various tests which either separately measure resistance to fire, resistance to fire with water, and resistance to fire with mechanical shock, or in combination measure resistance to fire with mechanical shock and water. BS EN 60702-1:2002 - Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V. Cables. These standards apply to mineral insulated cables. Those cables have an insulation completely different from those seen so far: they are extremely resistant but rigid. Their installation is not handy and a particular care has to be paid to the installation to prevent moisture absorption by the mineral oxide.
11
12
Standards at a glance
Behaviour to the fire of the electric cables
The contents of this section is an overview of the problems related to the state of the art behaviour of the electric and fibre optic cables in case of fire. The picture is quite complex, both for the problems critical state and for all the connections and prescriptions existing between the various standards. Deliberately we did not deepen this topic since this would require many more pages and it would be useless in this context. It is anyhow the position of Cavicel as far as the cable behaviour in case of fire in industrial plants is concerned; more detailed technical information could be required any time at our Technical Department.
(updated to March 2010)
13
Standards
BS BS 5266-1 BS 5839-1 British Standard Institution Emergency lighting. Code of practice for the emergency lighting of premises Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance Fire detection and fire alarm systems for buildings. Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings Fire detection and fire alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of voice alarm systems Fire detection and alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems Specification for performance requirements for cables required to maintain circuit integrity under fire conditions Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire Components for smoke and heat control systems. Specifications for cable systems Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. Multicore and multipair cables Electric cables. Thermosetting insulated, armoured, fireresistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification Methods of test for assessment of the fire integrity of electric cables. Test for unprotected small cables for use in emergency circuits. BS EN 50200 with a 930 flame and with water spray Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems Comitato Elettrotecnico Italiano EN (continued) EN 60332-2 EN 60332-3 EN 61034 IEC IEC 60228 IEC 60331 IEC 60332-1 Test for vertical flame propagation for a single small insulated wire or cable Test for vertical flame spread of vertically-mounted bunched wires or cables Measurement of smoke density of cables burning under defined conditions International Electrotechnical Commission Conductors of insulated cables - Guide to the dimensional limits of circular connectors Test for electrical cables under fire conditions. Circuit integrity. Tests on electric and optical fibre cables under fire conditions -Test for vertical flame propagation for a single insulated wire or cable Test on electric cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity Optical fibres Optical fibre cables Measurement of smoke density of electric cables burning under defined conditions (LT) Norme Belge Fire resistance of electical cables - Classification and test methods Fire resistance of building materials Norme Franaise Insulated cables and flexible cords for installations - Classification tests on cables and cords with respect to their behaviour to fire Singapore Standard Fire resistant cables - Performance requirements for cables required to maintain circuit integrity under fire conditions Verband der Elektrotechnik Elektronik Informationstechnik Wiring cables for telecommunication and data processing systems part 814 - Testing of cables, wires and flexible cords Continuance of insulation effect under fire conditions part 267 - Common test methods for cables under fire conditions - Test on gases evolved during combustion of materials from cables part 1034 - Measurement of smoke density of cables burning under defined conditions
BS 5839-6
BS 5839-8
BS 5839-9 BS 6387
IEC 60332-3
BS 7211
IEC 60502-1
BS 7346-6
IEC 60754-1 IEC 60754-2 IEC 60793-1 IEC 60794-1 IEC 61034-2 NBN NBN C 30-004 NBN 713-020 NF NF-C-32-070 SS SS 299 part 1 VDE
BS 7629-1
BS 7846
BS 8434-2
BS 8491 CEI
CEI 20-11 / Insulating, sheathing and covering materials for low voltage EN 50363 energy cables CEI 20-36/2-1 CEI 20-45 DIN DIN 4102 EN EN 50200 EN 50266 EN 50267/2-1 EN 50267/2-2 EN 50288-7 EN 50362 EN 50363 EN 60228 EN 60332-1 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV Fire resistant elastomeric insulated cables, halogen free (LSOH) with rated voltage Uo/U 0.6/1 kV Deutsches Institut fur Normung Fire behaviour of building materials and building components - Part 12: Circuit integrity maintenance of electric cable systems; requirements and testing European Norm Methods of test for resistance to fire of unprotected small cables for use in emergency circuit Test for vertical flame spread of vertically-mounted bunched wires and cables Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity Sectional specification for instrumentation and control cables Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits Insulating, sheathing and covering materials for low voltage energy cables Conductors of insulated cables Test for vertical flame propagation for a single insulated wire or cable
VDE 0815
VDE 0482
14
BS 6387 C-W-Z
NBN C 30-004
NBN 713-020
IEC 60331-21
IEC 60331-23
IEC 60331-25
SS 299 part 1
voltage rating
copper cable
DIN 4102-12
IEC 60502-1
EN 50288-7
BS 7629-1
CEI 20-45
CEI 20-36
VDE 0815
VDE 0472
EN 50200
BS 7211
BS 7846
BS 5839
silicone
armour
shield
SR 114H SR 114E SR 125 E30 SR 125 RF1 SR 125H SR 225 SR 118 SR 220 SR 109 SR 116H SR 112 SR 206 SR 106H SR 145 SR 140 SLO-FR MLO-FR
300/500 V 300/500 V 225 V 300 V 300/500 V 300/500 V 300/500 V 300/500 V 450/750 V 450/750 V 450/750 V 0,6/1 kV 0,6/1 kV 0,6/1 kV 0,6/1 kV 0,6/1 kV
standard
enhanced
PH30/PH60 PH120
PH90
PH90
PH90
PH120 PH90
= on request.
15
page 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, solid class 1 or stranded class 2 according to EN 60228. High performance fire resistant silicone rubber type EI2. Insulated cores are cabled together.
Overall screen
Aluminium/polyester tape. Uninsulated tinned copper conductor of the same section and class as the insulated conductors in the 2-, 3- and 4-core cables. Drain wire of 0.5 mm2 tinned copper conductor is provided in cables of more than 4 conductors.
Outer sheath
Applications
Firecel SR 114H are primarly intended for use in emergency lighting, fire detection and fire alarm system circuits. Tipical application are: BS 5266-1 for emergency lighting of premises BS 5839-1 for standard fire resistant cables in fire detection and fire alarm systems for building BS 5839-8 for voice alarm systems BS 5839-9 for emergency voice communication systems.
LSZH thermoplastic material type LTS3. Colour red or white (other colours on request).
Operating temperature
-40C to +90C
(on request the cores can be one colour only, identified by printed numbers)
Applicable Standards
Basic design BS 7629-1 Fire resistant BS 6387 (cat. C-W-Z) / EN 50200 (class PH30 and PH60) EN 50200 annex E (fire, mechanical shock and water spray) Flame retardant EN 60332-1-2 Acid gas emission EN 50267-2-1 Smoke density EN 61034-2
N of cond. x cross section (mm2) 1 mm2 solid 2x1,0 3x1,0 4x1,0 7x1,0 12x1,0 19x1,0 1,5 mm2 solid 2x1,5 3x1,5 4x1,5 7x1,5 12x1,5 19x1,5 1,5 mm2 stranded 2x1.5 3x1.5 4x1.5 2,5 mm2 solid 2x2.5 3x2.5 4x2.5 2,5 mm2 stranded 2x2,5 3x2,5 4x2,5 4 mm2 stranded 2x4 3x4 4x4 Outer diameter (mm) Weight (kg/km) 80 95 115 165 255 380
U-SR/OS/LSZH
7,1 8,0 8,3 10,0 12,5 15,0
U-SR/OS/LSZH
8,0 8,5 9,4 11,3 14,5 17,0 95 115 150 225 350 520
R-SR/OS/LSZH
8,4 8,9 9,8 106 134 166
U-SR/OS/LSZH
9,4 10,0 11,0 135 170 210
R-SR/OS/LSZH
9,9 10,3 11,8 145 180 250
R-SR/OS/LSZH
11,5 12,2 13,5 210 260 330 approximate values
16
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, solid class 1 or stranded class 2 according to EN 60228. Mica/Glass fire resistant tape covered by high performance fire resistant silicone rubber type EI2. Insulated cores are cabled together.
Overall screen
Aluminium/polyester tape. Uninsulated tinned copper conductor of the same section and class as the insulated conductors in the 2-, 3- and 4-core cables. Drain wire of 0.5 mm2 tinned copper conductor is provided in cables of more than 4 conductors.
Outer sheath
Applications
Firecel SR 114E are primarly intended for use in emergency lighting, fire detection and fire alarm system circuits. Tipical application are:
LSZH thermoplastic material type LTS3. Colour red or white (other colours on request)
BS 5266-1 for emergency lighting of premises BS 5839-1 for enhanced fire resistant cables in fire detection and fire alarm systems for building BS 5839-8 for voice alarm systems BS 5839-9 for emergency voice communication systems.
Operating temperature
-40C to +90C
(on request the cores can be one colour only, identified by printed numbers)
Applicable Standards
Basic design BS 7629-1 Fire resistant BS 6387 (cat. C-W-Z) / EN 50200 (class PH120) EN 50200 annex E (fire, mechanical shock and water spray) / BS 8434-2 (120 min) Flame retardant EN 60332-1-2 Acid gas emission EN 50267-2-1 Smoke density EN 61034-2
N of cond. x cross section (mm2) 1 mm2 solid 2x1,0 3x1,0 4x1,0 7x1,0 12x1,0 19x1,0 1,5 mm2 solid 2x1,5 3x1,5 4x1,5 7x1,5 12x1,5 19x1,5 1,5 mm2 stranded 2x1.5 3x1.5 4x1.5 2,5 mm2 solid 2x2.5 3x2.5 4x2.5 2,5 mm2 stranded 2x2,5 3x2,5 4x2,5 4 mm2 stranded 2x4 3x4 4x4 Outer diameter (mm) 7,9 8,4 9,3 10,5 14,5 17,5 Weight (kg/km) 85 105 125 175 300 470
U-mSR/OS/LSZH
U-mSR/OS/LSZH
8,8 9,3 10,3 12,1 16,0 17,5 105 130 165 230 380 470
R-mSR/OS/LSZH
9,2 9,4 10,5 110 135 170
U-mSR/OS/LSZH
10,2 10,8 12,0 150 190 240
R-mSR/OS/LSZH
10,3 10,9 12,1 155 190 250
R-mSR/OS/LSZH
12,2 13,0 14,4 220 280 350 approximate values
17
Cable construction
Conductors Insulation
Solid plain annealed copper wire. High performance fire resistant silicone rubber compound type HJ1.
Insulated cores are twisted to form pairs. Two-pair cable had four cores laid in quad formation. Pairs are cabled together. In cables with 8 pairs or more 4 pairs are assembled to form a bunch, the bunches are cabled together.
Flame barrier
Overall screen
Applications
Firecel SR 125 E30 are wiring cables for telecommunication and information processing systems where absence of halogen and improved properties in case of fire and specified continuance of insulation effect when exposed to flame. For fixed installation in dry and humid premises, may be embedded in plaster, not for power supply, external use or underground laying.
Outer sheath
LSZH thermoplastic material type HM2. Colour orange or red with printed BRANDMELDEKABEL for fire alarms.
Colour code
Each bunch blue - red / grey - yellow / green - brown / white - black Bunch identication plastic numbered tape
Applicable Standards
Basic design VDE 0815 Fire resistant VDE 0472-814 (FE180) / IEC 60331-23 Functionality of cabling system DIN 4102 Part 12 (E30) Fire retardant VDE 0472 Part 804 (test C) / EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) Flame retardant EN 60332-1-2 / IEC 60332-1-2 Acid gas emission VDE 0482-267 / EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 Smoke density VDE 0482-1034 / EN 61034-2 / IEC 61034-2
Operating temperature
-40C to +90C
N of pairs x conductor diameter section 0,5 mm2 solid 1x2x0,8 mm 2x2x0,8 mm (quad cabled) 4x2x0,8 mm section 0,5 mm2 solid 8x2x0,8 mm 12x2x0,8 mm 16x2x0,8 mm 20x2x0,8 mm 32x2x0,8 mm 40x2x0,8 mm 52x2x0,8 mm
Outer diameter (mm) 6,1 7,5 10,5 17,4 18,9 20,7 22,7 24,5 26,5 28,0
Weight (kg/km) 52 77 133 296 368 442 508 772 946 1016 approximate values
JE-H(St)H FE180/E30
JE-H(St)H Bd Z FE180/E30
18
Cable construction
Conductors Insulation
Solid plain annealed copper wire. High performance fire resistant silicone rubber. Insulated cores are twisted to form pairs. Two-pair cable had four cores laid in quad formation.
U-SR/OS/LSZH 300 V
Approved by ISIB (Institut de Securite Incendie - Belgium)
Flame barrier
Glass tape.
Applications
Firecel SR 125 RF1 are designed, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fire.
Colour code
Single pair Multipair white - blue white - blue numbered
Operating temperature
-40C to +90C
Applicable Standards
Fire resistant Fire retardant Flame retardant Acid gas emission Smoke density NBN C 30-004 (cat. F3) / NBN 713-020 (RF1) / EN 50200 (PH90) / IEC 60331-23 NBN C 30-004 (cat. F2) / EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) NBN C 30-004 (cat. F1) / EN 60332-1-2 / IEC 60332-1-2 EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of pairs x conductor diameter section 0,65 mm2 solid 1x2x0,9 mm 2x2x0,9 mm (quad cabled) 3x2x0,9 mm
U-SR/OS/LSZH
6,5 7,4 10,9
19
Cable construction
Conductors Insulation
Plain annealed copper wire, solid class 1 or stranded class 2 according to EN 60228. High performance fire resistant silicone rubber.
Insulated cores are twisted to form pairs. Pairs are cabled together.
Applications
Firecel SR 125H are designed, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fire.
Aluminium/polyester tape with copper drain wire. LSZH thermoplastic material Colour red (other colours on request).
Colour code
Cables up to 6 pairs black-red / black-blue / red-blue / yellow-black / yellow-red / yellow-blue Cables above 6 pairs all pairs black-red numbered on black conductors
Operating temperature
-40C to +90C
Applicable Standards
Basic design Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density BS 7629 EN 50200 (PH90) / EN 50362 (PH90) / IEC 60331-21 / BS 6387(cat. C-W-Z) / SS 299 part 1 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of pairs x cross section (mm2) 0,5 mm2 solid 1x2x0.5 2x2x0.5 3x2x0.5 5x2x0.5 6x2x0.5 10x2x0.5 15x2x0.5 20x2x0.5 1 mm2 stranded 1x2x1 2x2x1 3x2x2 5x2x1 6x2x1 10x2x1 15x2x1 20x2x1 1,5 mm2 stranded 1x2x1.5 2x2x1.5 3x2x1.5 5x2x1.5 6x2x1.5 10x2x1.5 15x2x1.5 20x2x1.5
U-SR/OS/LSZH
6,5 9,5 10,5 12,0 13,0 16,5 20,5 22,6
R-SR/OS/LSZH
7,4 10,6 11,2 13,7 14,8 18,9 23,2 26,2 77 130 196 245 300 378 567 831
R-SR/OS/LSZH
8,7 10,2 12,9 16,7 17,5 23,4 28,9 32,5 100 188 223 346 426 541 892 1182 approximate values
20
Cable construction
Conductors Insulation
Plain annealed copper wire, stranded according to EN 60228 class 2. Mica/Glass fire resistant tape covered by extruded cross-linked XLPE compound.
R-mXLPE/OS/LSZH 300/500 V
Insulated cores are twisted to form pairs. Pairs are cabled together.
Applications
Firecel SR 225H are designed, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fire.
Aluminium/polyester tape with copper drain wire. LSZH thermoplastic material. Colour red (other colours on request).
Colour code
According to IEC 60189-2 (other colour code on request).
Operating temperature
-40C to +90C
Applicable Standards
Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density IEC 60331-23 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of pairs x cross section (mm2) 0,75 mm2 stranded 1x2x0.75 2x2x0.75 5x2x0.75 10x2x0.75 15x2x0.75 20x2x0.75 1 mm2 stranded 1x2x1 2x2x1 5x2x1 10x2x1 15x2x1 20x2x1 1,5 mm2 stranded 1x2x1.5 2x2x1.5 5x2x1.5 10x2x1.5 15x2x1.5 20x2x1.5
Weight (kg/km) 64 118 218 380 535 680 73 136 266 455 646 839 87 165 342 606 862 1121 approximate values
R-mXLPE/OS/LSZH
R-mXLPE/OS/LSZH
8,4 11,5 15,7 21,3 26,5 30,2
R-mXLPE/OS/LSZH
9,3 13,0 18,1 24,8 30,8 34,9
21
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, solid according to EN 60228 class 1. High performance fire resistant silicone rubber type EI2.
Firecel SR 118
U-SR/LSZH 300/500 V
Approved by ISIB (Institut de Securite Incendie - Belgium)
Outer sheath
LSZH thermoplastic material type HM2. Colour orange (other colours on request).
Operating temperature
-40C to +90C (for insulated conductors only: max 200C).
Applicable Standards
Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density NBN C 30-004 (cat. F3) NBN 713-020 (RF1 for section 1,5 mm2, RF1.5 for section 2,5 mm2) EN 50200 (PH90) / IEC 60331-21 NBN C 30-004 (cat. F1) / EN 60332-1-2 / IEC 60332-1-2 NBN C 30-004 (cat. F2) / EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of cond. x cross section (mm2) 1,5 mm2 solid 2x1,5 3x1,5 4x1,5 2,5 mm2 solid 2x2,5 3x2,5 4x2,5
U-SR/LSZH
7,4 7,9 8,8
U-SR/LSZH
8,8 9,4 10,4 105 141 183 approximate values
22
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, stranded according to EN 60228 class 2. Mica/Glass fire resistant tape covered by extruded cross-linked XLPE compound.
Firecel SR 220
R-mXLPE/LSZH 300/500 V
Applications
Firecel SR 220 are designed, manufactured and tested for general application.
Outer sheath
Operating temperature
-40C to +90C
Applicable Standards
Basic design Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density EN 50288-7 IEC 60331-21 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of cond. x cross section (mm2) 0,75 mm2 stranded 2x0.75 3x0.75 4x0.75 1 mm2 stranded 2x1 3x1 4x1 7x1 12x1 19x1 1,5 mm2 stranded 2x1.5 3x1.5 4x1.5 7x1.5 12x1.5 19x1.5 2,5 mm2 stranded 2x2.5 3x2.5 4x2.5 7x2.5 12x2.5 19x2.5
R-mXLPE/LSZH
7,3 8,0 8,7
R-mXLPE/LSZH
7,9 8,4 9,4 11,3 15,1 18,0 82 96 121 174 282 424
R-mXLPE/LSZH
8,5 9,3 10,1 12,2 16,5 19,5 100 126 150 220 365 544
R-mXLPE/LSZH
9,7 10,4 11,5 14,0 18,8 22,4 139 168 206 310 514 782 approximate values
23
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, flexible according to EN 60228 class 5. High performance fire resistant silicone rubber. Insulated cores are cabled together.
F-SR/OS/LSZH 450/750 V
Applications
Firecel SR 109 are designed, manufactured and tested for general application in power and signal wiring, for emergency circuit and fire circuit control where high rejection to electrostatic noise is needed.
Operating temperature
-40C to +90C
Applicable Standards
Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density CEI 20-36/2-1 / EN 50200 (PH120) / IEC 60331-21 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of cond. x cross section (mm2) 0,75 mm2 flexible 2x0.75 3x0.75 4x0.75 1 mm2 flexible 2x1 3x1 4x1 7x1 12x1 19x1 1,5 mm2 flexible 2x1.5 3x1.5 4x1.5 7x1.5 12x1.5 19x1.5 2,5 mm2 flexible 2x2.5 3x2.5 4x2.5 7x2.5 12x2.5 19x2.5
F-SR/OS/LSZH
7,6 8,0 8,7
F-SR/OS/LSZH
8,0 8,2 8,9 10,8 13,9 16,4 78 86 110 176 275 408
F-SR/OS/LSZH
8,3 8,8 9,8 11,7 15,3 18,2 88 112 141 218 352 535
F-SR/OS/LSZH
9,8 10,4 11,4 13,4 17,9 21,1 123 159 196 305 505 760 approximate values
24
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, stranded according to EN 60228 class 2. High performance fire resistant silicone rubber.
Firecel SR 116H
R-SR/LSZH 450/750 V
Applications
Firecel SR 116H are designed, manufactured and tested for general application in power supply and signal wiring, for emergency circuit and fire circuit control.
Outer sheath
Operating temperature
-40C to +90C (for insulated conductors only: max 200C).
Applicable Standards
Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density CEI 20-36/2-1 / EN 50200 (PH90) / IEC 60331-21 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of cond. x cross section (mm2) 1,5 mm2 stranded 2x1,5 3x1,5 4x1,5 5x1,5 2,5 mm2 stranded 2x2,5 3x2,5 4x2,5 5x2,5 4 mm2 stranded 2x4 3x4 4x4 5x4
R-SR/LSZH
7,8 8,3 9,3 10,5
R-SR/LSZH
9,2 9,8 11,3 12,3 138 169 222 259
R-SR/LSZH
10,5 11,6 12,5 14,0 189 246 299 359 approximate values
25
Cable construction
Conductors Insulation Twisting
Plain annealed copper wire, stranded according to EN 60228 class 2. Mica/Glass fire resistant tape covered by extruded cross-linked compound type EI5. Only for FIRECEL SR 112X two conductors are twisted.
Colours
Single core Twin core Red - black - blue - brown (other colours on request) Red - black (other colours on request)
Applicable Standards
Basic design Fire resistant Acid gas emission Smoke density BS 7211 BS 6387 (cat.C-W-Z tested in steel conduit) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
Applications
Firecel SR 112 are designed, manufactured and tested as cable fixed or protected installation for power supply, lighting and control gear.
Operating temperature
-40C to +90C
SR 112 R-mXLSZH
26 38 60 84 128 190 294
SR 112X R-mXLSZH
52 76 120 168 256 380 588 approximate values
26
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, stranded according to EN 60228 class 2. Mica/Glass fire resistant tape covered by extruded cross-linked XLPE compound. Insulated cores are cabled together.
Firecel SR 206
R-mXLPE/LSZH 0.6/1 kV
Outer sheath
Applications
Power supply and signals trasmission, indoors or outdoors even wet environment. For fixed laying in free air, in pipe or conduit, on masonry and metal structures or suspended. In places where in case of fire people are exposed to serious risks for emission of smoke, toxic and corrosive gases and where you want to avoid damage to facilities, equipment, goods. Suitable for feeding of: emergency exits, alarm signals, warning of smoke or gas, escalators. Suitable for laying underground direct or indirect.
LSZH thermoplastic material type ST8. Colour red (other colours on request).
Operating temperature
-40C to +90C
Applicable Standards
Basic design IEC 60502-1 Fire resistant IEC 60331-21 Flame retardant IEC 60332-1-2 Fire retardant IEC 60332-3-24 (cat. C) Acid gas emission IEC 60754-1 Smoke density IEC 61034-2
N of cond. x cross section (mm2) 1,5 mm2 stranded 2x1,5 3x1,5 4x1,5 5x1,5 2,5 mm2 stranded 2x2,5 3x2,5 4x2,5 5x2,5 4 mm2 stranded 2x4 3x4 4x4 5x4 6 mm2 stranded 2x6 3x6 4x6 5x6 10 mm2 stranded 2x10 3x10 4x10 5x10 16 mm2 stranded 2x16 3x16 4x16 5x16 25 mm2 stranded 2x25 3x25 4x25 5x25
R-mXLPE/LSZH
10,4 10,9 11,8 12,9
R-mXLPE/LSZH
11,2 11,8 12,8 14,0 180 209 250 289
R-mXLPE/LSZH
12,3 13,0 14,1 15,5 230 275 331 387
R-mXLPE/LSZH
14,6 15,5 16,9 18,6 329 397 482 565
R-mXLPE/LSZH
16,4 17,4 19,1 21,0 450 554 682 805
R-mXLPE/LSZH
18,5 19,7 20,3 23,9 619 777 1050 1208
R-mXLPE/LSZH
22,0 23,5 26,0 28,7 914 1161 1500 1700 approximate values
27
Cable construction
Conductors Insulation
Plain annealed copper wire, stranded class 2 for section up to 10 mm2 or flexible class 5 for section above 10 mm2 according to EN 60228. High performance fire resistant silicone rubber.
Firecel SR 106H
Cabling
Outer sheath
Applications
Power supply and signals trasmission, indoor or outdoor even wet environment. For fixed laying in free air, in pipe or conduit, on masonry and metal structures or suspended. In places where in case of fire people are exposed to serious risks for emission of smoke, toxic and corrosive gases and where you want to avoid damage to facilities, equipment, goods. Suitable for feeding of: emergency exits, alarm signals, warning of smoke or gas, escalators. Suitable for laying underground direct or indirect.
Operating temperature
-40C to +90C (for insulated conductors only: max 200C).
Applicable Standards
Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density EN 50200 (PH90) / EN 50362 (PH90) / IEC 60331-21 / BS 6387 (cat. C-W-Z) / SS 299 part 1 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
N of cond. x cross section (mm2) 1,5 mm2 stranded 2x1,5 3x1,5 4x1,5 5x1,5 2,5 mm2 stranded 2x2,5 3x2,5 4x2,5 5x2,5 4 mm2 stranded 2x4 3x4 4x4 5x4 6 mm2 stranded 2x6 3x6 4x6 5x6 10 mm2 stranded 2x10 3x10 4x10 5x10 16 mm2 flexible 2x16 3x16 4x16 5x16
R-SR/LSZH
9,2 9,8 10,6 11,5
R-SR/LSZH
10,0 10,6 11,5 12,6 155 188 228 266
R-SR/LSZH
11,2 12,1 13,6 14,5 207 263 332 399
R-SR/LSZH
13,1 14,4 15,8 17,6 298 372 463 576
R-SR/LSZH
15,9 16,8 18,5 20,5 441 541 680 850
F-SR/LSZH
17,4 19,4 21,2 23,3 602 777 973 1202 approximate values
28
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, flexible according to EN 60228 class 5. Mica/Glass fire resistant tape covered by extruded cross-linked compound type G10. Insulated cores are cabled together.
Firecel SR 145
Outer sheath
Applications
Applications Power supply and signals trasmission, indoors or outdoors even wet environment. For fixed laying in free air, in pipe or conduit, on masonry and metal structures or suspended. In places where in case of fire people are exposed to serious risks for emission of smoke, toxic and corrosive gases and where you want to avoid damage to facilities, equipment, goods. Suitable for feeding of: emergency exits, alarm signals, warning of smoke or gas, escalators. Suitable for laying underground direct or indirect.
LSZH thermoplastic compound type M1. Colour blue (other colours on request).
Applicable Standards
Basic design CEI 20-45 Fire resistant EN 50200 (PH90) / EN 50362 (PH90) / IEC 60331-21 Flame retardant EN 60332-1-2 Fire retardant EN 50266-2-4 (cat. C) Acid gas emission EN 50267-2-1 Smoke density EN 61034-2 Toxicity CEI 20-37/4-0
N of cond. x cross section (mm2) 1,5 mm2 flexible 1x1,5 2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 12x1,5 19x1,5 24x1,5 2,5 mm2 flexible 1x2,5 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 12x2,5 19x2,5 24x2,5 4 mm2 flexible 1x4 2x4 3x4 4x4 5x4 6 mm2 flexible 1x6 2x6 3x6 4x6 5x6 10 mm2 flexible 1x10 2x10 3x10 4x10 5x10 16 mm2 flexible 1x16 2x16 3x16 4x16 5x16 25 mm2 flexible 1x25 2x25 3x25 4x25 5x25 Outer diameter (mm) 6,7 11,4 12,0 13,0 13,7 16,3 19,4 23,9 26,5 7,3 12,3 13,0 14,1 15,4 17,7 21,4 26,2 29,8 7,7 13,4 14,2 15,5 17,1 8,5 15,0 15,9 17,4 19,3 10,5 18,3 19,5 21,4 24,3 11,8 21,5 22,9 25,2 28,1 13,7 25,4 27,2 30,2 33,5 Weight (kg/km) 78 168 193 227 260 340 510 760 910 90 204 238 283 358 414 665 969 1200 98 255 302 363 482 123 341 412 502 620 198 510 620 859 1092 273 729 897 1107 1301
Operating temperature
-40C to +90C
F-mG10/LSZH
F-mG10/LSZH
F-mG10/LSZH
F-mG10/LSZH
F-mG10/LSZH
F-mG10/LSZH
F-mG10/LSZH
29
Cable construction
Conductors Insulation Cabling
Plain annealed copper wire, stranded according to EN 60228 class 2. Mica/Glass fire resistant tape covered by extruded cross-linked XLPE compound. Insulated cores are cabled together.
R-mXLPE/LSZH/SWA/LSZH 0.6/1 kV
Bedding Armour
Applications
Power supply and signals trasmission, indoors or outdoors even wet environment. For fixed laying in free air, in pipe or conduit, on masonry and metal structures or suspended. In places where in case of fire people are exposed to serious risks for emission of smoke, toxic and corrosive gases and where you want to avoid damage to facilities, equipment, goods. Suitable for feeding of: emergency exits, alarm signals, warning of smoke or gas, escalators. Suitable for laying underground direct or indirect.
Outer sheath
Applicable Standards
Basic design Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density BS 7846 BS 7846 (cat. F2) / BS 6387 (cat. C-W-Z) / EN 50200 (PH60) EN 60332-1-2 EN 50266-2-4 (cat. C) EN 50267-2-1 EN 61034-2
Diameter under armour (mm) 8,8 9,8 10,6 12,8 16,8 19,4 23,3 26,4 9,6 10,7 11,2 13,8 18,2 21,4 25,8 29,2 11,1 11,8 12,9 15,6 20,9 12,3 13,1 14,4 14,9 16,1 17,7 17,1 18,3 20,2 20,3 21,8 24,1 22,7 24,3 27,0 Outer diameter (mm) 13,8 14,8 15,6 18,2 23,1 26,4 30,5 34,0 14,6 15,7 16,2 19,9 25,4 28,8 33,4 37,8 16,1 16,8 17,9 21,7 28,1 17,3 18,1 20,5 19,9 22,2 23,8 22,5 24,4 26,5 26,6 28,8 31,3 29,9 31,7 34,4 Weight (kg/km) 364 418 460 607 988 1390 1760 2175 416 480 514 818 1312 1705 2180 2950 510 570 649 1004 1642 600 680 927 800 1078 1256 1034 1354 1625 1530 1972 2355 2055 2450 2943 approximate values
Operating temperature
-40C to +90C
N of cond. x cross section (mm2) 1,5 mm2 stranded 2x1,5 3x1,5 4x1,5 7x1,5 12x1,5 19x1,5 27x1,5 37x1,5 2,5 mm2 stranded 2x2,5 3x2,5 4x2,5 7x2,5 12x2,5 19x2,5 27x2,5 37x2,5 4 mm2 stranded 2x4 3x4 4x4 7x4 12x4 6 mm2 stranded 2x6 3x6 4x6 10 mm2 stranded 2x10 3x10 4x10 16 mm2 stranded 2x16 3x16 4x16 25 mm2 stranded 2x25 3x25 4x25 35 mm2 stranded 2x35 3x35 4x35
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
R-mXLPE/LSZH/SWA/LSZH
30
Cable construction
Fibres
Singlemode and multimode fibres, with loose technology coating.
Single Tube
Structure
SLO-000-**-M1-A5-FR SLO-000-**-M1-A1-FR
Multi Tube
For type SLO-FR the jelly filled tube containing the fibres is reinforced with glass yarns and is wound with a flame resistant tape. For type MLO-FR the jelly filled tubes containing the fibres are individually wound with a mica tape and are cabled around a central steel or FRP (fibreglass reinforced plastic) element. When necessary glass yarn is the traction element. A flame resistant tape improves fire resistance.
Armouring
Applications
These cables are mainly used inside buildings, tunnels or closed areas in general, are designed and manufactured to guarantee the signal transmission even in case of fire, thus safeguarding the operation of the safety systems or of particularly critical and high speed connections.
A1 Galvanized steel wire braid A3 Corrugated steel tape A5 Anti-rodent glass yarns
Outer sheath
Applicable Standards
Optical fibre characteristics Fire resistant Flame retardant Fire retardant Acid gas emission Smoke density IEC 60793-1 / IEC 60794-1 IEC 60331-25 EN 60332-1-2 / IEC 60332-1-2 EN 50266-2-4 (cat. C) / IEC 60332-3-24 (cat. C) EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 EN 61034-2 / IEC 61034-2
Temperature range
-40C to +90C
Tube diameter (mm) -**- number of fibres 2 6 8 16 18 24 -**- number of fibres 2 6 8 16 18 24 -**- max number of fibres 72 96 144 -**- max number of fibres
MLO-FR-A5 MLO-FR-A3 MLO-FR-A1 (DNV-QFCI)
Weight (kg/km) 70 90 100 160 180 200 230 250 280 290 350 450 230 250 approximate values
SLO-000-**-M1-A5-FR
2,7 3,5 4,2 2,7 3,5 4,2 2,5 2,5 2,5 2,5 2,5 2,5 2,5 3,0
SLO-000-**-M1-A1-FR
11,5 12,0 13,0
MLO-000-**(n)-M1-A5-FR
15,0 16,5 20,5
MLO-000-**(n)-M1-A3-FR
16,5 18,5 22,5 13,5 14,5
SLO-FR-A5
SLO-FR-A1
MLO-000-**(n)-M1-A1-FR (DNV-QFCI)
31
Fire Tests
Cables have to be properly designed, manufactured and also tested. Many tests are carried out during manufacturing or as final inspections. Many of them are attended by customers or third part inspectors. The tests are part of R&D, an extremely strategic activity for a Company and this is the reason why CAVICEL has invested in this field. You can find here the main tests concerning the behaviour of cables under fire conditions, and our main test equipments. It is important to verify all required performances and give the customers the full compliance to the requirements. CAVICEL is proud of its own laboratories and customers are always welcome to visit them.
BS 6387
Following tests are carried out to verify if a cable is capable of maintaining circuit integrity under fire condition, fire with water, and fire with mechanical shocks. During the tests the cables are maintained at their rated voltage. Fire Resistance (Cat. A B C S) The cable is exposed to fire at the specified temperature and time.
BS EN 50200
Fire Resistance This test is carried out to verify the circuit integrity of cables exposed to fire at 850C and mechanical shocks.
Classification PH 15 Fire and Water Resistance (Cat. W) The cable is exposed for 15 minutes to flame at 650C and for additional 15 minutes to fire and water spray. PH 30 PH 60 PH 90 PH 120 flame exposure for 15 min flame exposure for 30 min flame exposure for 60 min flame exposure for 90 min flame exposure for 120 min
Performance Table Test Fire Resistance 650 C for 3 hours 750 C for 3 hours 950 C for 3 hours 950 C for 20 minutes Resistance to Fire and Water 650 C 650 C 750 C 950 C W X Y Z Resistance to Fire with Mechanical Shock A B C S Category
32
Fire Tests
NF C 32-070
Fire Resistance This test is carried out to verify circuit integrity during a fire. The cable is into a tubular oven with gradually increasing of temperature up to 920C. The cable is stressed by mechanical shocks and subjected to tensile strength.
Standard
Standard
BS EN 60332-1, IEC 60332-1, CEI 20-35/1 BS EN 60332-2, IEC 60332-2, CEI 20-35/2, for small diameter cables
Flame Propagation Test on a Single Cable A 60 cm long sample of cable is vertically fixed with two clamps inside a small cabin, open on the front. The cable is subjected to the action of a flame produced by a calibrated Bunsen burner. The application time of the flame is according to the cable diameter 60-480 seconds ). At the end of the test the burnt portion of cable must not be 50 mm close to the higher clamp.
LSZH cable
PVC cable
Fire source on
10
20
40
33
Unwinding
To unwind cables during installation, please refer to following pictures.
CORRECT
CORRECT
INCORRECT
INCORRECT
CORRECT
INCORRECT
CORRECT
Storage
Cable drums should be stored so that the drum flanges do not contact cable on another drum.
Battens, where applied, should not be removed from drums until the cables are to be installed. Care should be taken to avoid injury with nails when removing battens. To remove possible plastic foil on cable, do not use sharp tools that could damage cable jacket.
CORRECT
INCORRECT
Cables stored at temperatures which are below those recommended for installation conditions, should not be subjected to any mechanical stress including shocks, impact, bending and torsion. If cables are not fully protected (with battens or plastic foils for example), store should be in a protected area and not weather-beaten. The cable end should be sealed to prevent ingress of moisture during transport and storage.
34
We have tried, with this catalogue, to show you our experience, our way of thinking and operating in the creation of fire resistant cables. We believe the cables you have seen here are good practical examples. When it comes to your own cable we can co-design it together: you let us know your specific situation and we will create your cable all around it. Cavicel can create it for you. Thank you for calling Cavicel.
35
Conducting Value
CAVICEL SpA 20096 Pioltello (Milano) - Italy Via Caduti del Lavoro, 18/A tel. +39 - 02 - 921.605.21 fax +39 - 02 - 921.607.53 e-mail: cavicel@cavicel.com www.cavicel.com
MADE IN ITALY
Cavicel firmly believes in the importance of the quality of its products and it undertakes itself to produce them using clean technologies for the respect and the protection of the environment.
All information contained in this brochure is believed to be accurate. Specifications can change at any time, according to technical developments and market changes.