Global Lifting Services Ltd

CERTIFICATE OF TEST,EXAMINATION AND MPI


CLIENT :BP TRINIDAD & TOBAGO LLC PO BOX 714 PORT OF SPAIN TRINIDAD TEST HOUSE :Global Lifting Services Ltd 172 Eastern Main Road Barataria Trinidad and Tobago www.globallifting.co.uk Tel (868) 675-6009 Fax (868) 675-6009 DEPARTMENT
CASSIA A

CERTIFICATE No.
13754/0006

DATE OF EXAMINATION
02/03/11

I.D. NUMBER 15-LKR7510C

QTY 1

BP BOX 714 DESCRIPTION PO TRINIDAD & TOBAGO LLC SWL/Payload PORT OF SPAIN TRINIDAD

PROOF LOAD
387.5 lbs

KNOTTED ROPE STATION Location : North east production deck

310 lbs

M.P.I. INSPECTION DETAILS


Standard :- BS6072 : 1981 Test Procedure No. :- QP9.5 RESULTS Equipment Type :- PERMANENT MAGNET Pole Spacing :100mm Contrast Media :Indicator :Inspector :Qualification :NPT16 WHITE PAINT BLACK INK K.Thomas SNT L11

A MAGNETIC PARTICAL INSPECTION WAS CARRIED OUT ON THE LIFTING POINT :WELDS OF THE ABOVE EQUIPMENT. NO CRACKS OR CRACKLIKE INDICATIONS WERE NOTED AT THE TIME OF INSPECTION.

(a) The Lifting Operations and Lifting Equipment Regulations 1998 S.I. No. 2307 (b) The Supply of Machinery (Safety) Regulations 1992 S.I. No. 3073 (c) The Provision and Use of Work Equipment Regulations 1998 S.I. No. 2306

(868) 675-6009Services Global LiftingTobago www.globallifting.co.ukLtd Trinidad Baratariaand 172 Eastern Main Road

I hereby certify that the equipment described on this certificate has been tested visually examined and found to be free from flaws or other defects. FORM QAF50B REV 2 SIGNATURE :K.Thomas 17-Mar-11