You are on page 1of 1

RIGZONE SERVICES NIGERIA LIMITED

PLOT 7 PEACE ESTATE,BEHIND FIRST BANK EASWEST ROAD, PORT HARCOURT-NIGERIA


TEL:+234-8055422941 , E-mail: rigzoneservices@gmail.com ; https://rigzoneservicesng.com

CLIENT: EXAMINATION LOCATION:


ALLMAN GLOBAL SERVICES NIGERIA LTD ALLMAN GLOBAL SERVICES NIGERIA LTD
IGWURUTA-PORT HARCOURT IGWURUTA-PORT HARCOURT

CERTIFICATE NO. SERVICE ORDER NO. DATE OF EXAMINATION NEXT EXAMINATION DUE
RS22/AGS/0404 TBA 15/04/2022 14/10/2022
MAGNETIC PARTICLE EXAMINATION REPORT
UNIT DESCRIPTION: CENTRIFUGE STAND -4 LIFTING INSPECTION DETAILS WITH PICTURES/SKETCH
POINTS WITH TARE WEIGHT=1380 KG FULL MPI & VISUAL INSPECTION CARRIED OUT ON THE WELDED
DIMENSIONS: 4.460MTR X 2.8 MTR X 2MTR( ADJUSTIBLE LOAD BEARING PADEYES OF THE UNIT AS SHOWN BELOW
HIEGHT)
UNIT IDENTIFICATION CODE: AGS/CS/001
MPI DETAILS:
SPECIFICATION: API SPEC 5D
PROCEDURE: RSWI 9.5.1

SURFACE CONDITION: BARE METAL


MAGNETIZING TECHNIQUE: MAGNETIC FLUX/FLOW
FIELD STRENGHT VERIFICATION: FLUX INDICATOR

MAGNETIC PARTICLE PROCESS:


WET: X DRY:
VISIBLE: X FLOURESCENT

DETECTION MEDIA:- BATCH NO.:- MAKE:-


BLACK MAGNETIC INK 0900053842 SUPRAMOR
VIEWING CONDITION: 500 LUX COLOURED MEDIA

EQUIPMENT USED: METHOD STATEMENT: 100% MAGNETIC PARTICLE INSPECTION


ITEM ID NO. CAL. DUE DATE WAS CARRIED OUT ON THE 4 WELDED LOAD BEARING LIFTING
ELECTROMAGNET N/A N/A POINTS OF THE UNIT. NO CRACKLIKE INDICATIONS,DENT,
PERM. MAGNET 1907 01/08/2022 GOURGE OR LIKELY IMPRESSION WERE FOUND AS AT THE TIME
OF EXAMINATION.
U.V. LIGHT N/A N/A RESULT CONFIRMED: THE ABOVE ASSEMBLY HAS BEEN FOUND
TO BE WITHIN THE ACCEPTABLE CRITERIA AS AT THE TIME OF
INSPECTION. IT IS FIT FOR USE
DECLARATION: NAME & QUALIFICATION OF EXAMINER WITH SIGNATURE:

I HEREBY DECLARE THAT THE ABOVE INFORMATIONS ARE


CORRECT AND THE EQUIPMENT(S) HAS BEEN THOROUGHLY
EXAMINED IN ACCORDANCE WITH THE APPROPRIATE
PROVISIONS.

SIGNATURE___________________________
NAME : JONAH OLLAWA; SNT-TC-1A

You might also like