PROCEDURE FOR TREATMENT OF BOREHOLE WATER

DILUTE 500G OF CHLORINE WITH WATER AND POUR INTO DOSING PUMP TANK 1(100 LTS) AND STIR. DILUTE 500G OF SODA ASH AND WATER AND POUR INTO DOSING PUMP TANK 2(100 LTS) AND STIR. TURN OPERATION SWITCH TO AUTO POSITION FOR BOREHOLE,COMPRESSOR,DOSING PUMPS. ENSURE WATER IS GETTING INTO THE BOREHOLE TANK(5,000 LTS). ENSURE MIXING IS DONE UNTILL CIRCUIT CUT OFF AUTOMATICALLY. ALLOW WATER TO SETTLE FOR 6 HOURS. OBSERVE QUALITY OF WATER FROM FILTER DISCHARGE THROUGH BALL VALVE GOING TO GUTTER OPEN WHILE THAT LEADING TO UNDERGROUND TANK REMAINED CLOSED. IF OK TRANSFER WATER TO UNDERGROUND TANK VIA FILTERIN UNITS (ONLY AT DAY TIME). WHEN FINISHED DRAIN SLUDGE DEPOSIT. DO BACKWASHING OF THE FILTER UNITS BY SWITCHING VALVES TO REVERS POSITION. OBSERVE CLARITY OF WATER UNTIL CLEAR THEN RETURN THE BALL VALVE TO NORMAL POSITIONS TO ALLOW CLEAN WATER INTO UNDERGROUND TANK ON NEXT TRANSFER.
PREPAIRED BY MAINTENANCE.