You are on page 1of 1

USPC System Selection and Estimated Performance Table for GRUNDFOS 4", 200-230V, 3-Phase, 60 Hz Submersible Pumps

Selection of proper pump and array:


Step 1.
Step 2.
Step 3.

Step 5.

Step 7.

Array Rated Power (W)


Gallons / Day

15

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
30

Gallons / Day
50

Gallons / Day
75

344

516

640

720

800

880

1100

1320

100

3680

4600

6000

7200

11,000

12,500

17,400

18,700

19,800

22,500

36,900

43,500

57,900

70,500

114,000

132,000

153,000

168,000

25S05-3

40S10-3

40S10-3

40S10-3

40S10-3

150S20-1

150S20-1

150S20-1

150S20-1

300S75-2**

300S75-2**

300S75-2**

300S75-2**

9.8 / 10 / 41

26 / 20 / 45

28 / 20 / 48

40 / 20 / 41

41 / 20 / 43

43 / 20 / 45

47 / 20 / 48

105 / 30 / 41

120 / 30 / 43

145 / 30 / 48

165 / 30 / 52

260 / 10 / 40

285 / 10 / 43

320 / 10 / 47

335 / 10 / 51

3,500

6,550

10,100

11,000

11,900

12,600

16,200

19,200

22,000

29,800

40,700

62,900

95,200

118,000

136,000

10S03-6 *

16S05-5

25S07-5

25S07-5

25S07-5

25S07-5

40S10-3

40S10-3

75S20-3

75S20-3

150S20-1

150S20-1

300S75-2**

300S75-2**

300S75-2**

9.0 / 20 / 41

16 / 20 / 45

23 / 20 / 43

25 / 20 / 45

26 / 20 / 47

28 / 20 / 48

41 / 30 / 48

46 / 30 / 52

61 / 30 / 43

76 / 30 / 48

110 / 40 / 53

160 / 40 / 60

225 / 20 / 43

270 / 20 / 47

305 / 20 / 51

1,700

4,100

6,500

7,550

8,500

9,350

11,600

13,400

15,000

21,900

25,800

37,100

51,300

59,700

96,100

5S03-9 *

10S05-9

25S07-5

25S07-5

25S07-5

25S07-5

25S07-5

25S07-5

25S07-5

40S15-5

40S15-5

75S20-3

150S50-2

150S50-2

300S75-2**

4.3 / 20 / 42

10 / 20 / 45

18 / 30 / 43

20 / 30 / 45

22 / 30 / 47

24 / 30 / 48

28 / 30 / 52

31 / 30 / 56

34 / 30 / 59

51 / 30 / 54

58 / 30 / 59

94 / 40 / 60

138 / 40 / 51

155 / 40 / 54

245 / 30 / 51

2,000

4,500

5,200

6,250

6,400

8,400

10,300

11,900

16,300

20,800

25,900

37,900

42,000

45,600

5S05-13

16S07-8

16S07-8

25S10-7

16S07-8

25S07-5

25S07-5

25S07-5

40S15-5

40S15-5

60S20-4

75S30-3

75S50-8

75S50-8

5.0 / 20 / 45

13 / 30 / 43

14 / 30 / 45

17 / 30 / 43

16 / 30 / 48

22 / 40 / 53

26 / 40 / 56

29 / 40 / 59

43 / 40 / 54

52 / 40 / 59

69 / 40 / 60

94 / 40 / 60

92 / 30 / 54

100 / 30 / 58

2,900

3,350

4,650

5,200

6,600

7,850

9,100

12,900

14,700

22,100

29,700

35,200

40,900

10S07-12

10S07-12

16S07-8

16S07-8

16S07-8

16S07-8

25S07-5

25S10-7

40S15-5

40S20-7

75S30-3

75S50-8

75S50-8

8.0 / 30 / 43

8.9 / 30 / 45

12 / 30 / 47

14 / 30 / 48

17 / 30 / 52

19 / 30 / 56

24 / 40 / 60

32 / 40 / 60

42 / 40 / 60

54 / 40 / 60

78 / 40 / 60

85 / 30 / 54

95 / 30 / 58

2,000

2,800

3,200

3,550

5,400

6,600

7,700

10,700

12,500

18,400

22,300

28,700

34,800

7S07-15

10S07-12

10S07-12

10S07-12

16S07-8

16S07-8

16S07-8

25S10-7

25S15-9

40S20-7

40S30-9

75S50-8

75S50-8

5.5 / 30 / 43

7.6 / 30 / 45

8.4 / 30 / 47

9.1 / 30 / 48

14 / 40 / 53

17 / 40 / 56

19 / 40 / 59

28 / 40 / 60

31 / 40 / 59

48 / 40 / 60

54 / 40 / 60

76 / 40 / 54

87 / 40 / 58

1,700

2,000

2,250

2,500

3,650

5,450

6,500

8,700

10,600

13,000

19,100

23,200

29,200

7S07-15

7S07-15

7S07-15

7S07-15

10S07-12

16S07-8

16S07-8

25S10-7

25S15-9

25S20-11

40S30-9

75S50-8

75S50-8

4.7 / 30 / 43

5.4 / 30 / 45

5.9 / 30 / 47

6.4 / 30 / 48

9.8 / 40 / 52

14 / 40 / 57

17 / 40 / 60

24 / 40 / 60

28 / 40 / 59

32 / 40 / 60

50 / 40 / 60

65 / 40 / 54

78 / 40 / 58

1,150

1,500

1,650

2,350

3,400

4,100

6,200

8,000

10,300

13,000

17,500

21,000

5S10-22

5S07-18

5S07-18

7S07-15

10S07-12

10S07-12

16S10-10

16S15-14

25S20-11

25S30-15

40S50-15

40S50-15

3.3 / 30 / 41

3.9 / 30 / 47

4.3 / 30 / 48

6.4 / 40 / 52

9.3 / 40 / 56

11 / 40 / 59

17 / 40 / 60

20 / 40 / 59

27 / 40 / 60

32 / 40 / 60

46 / 40 / 54

52 / 40 / 58

1,650

2,300

2,800

4,300

6,600

8,300

11,000

13,800

17,300

5S07-18

7S07-15

7S07-15

10S10-15

16S15-14

16S20-18

25S30-15

40S50-15

40S50-15

4.5 / 40 / 52

6.3 / 40 / 56

7.4 / 40 / 60

11 / 40 / 60

17 / 40 / 59

20 / 40 / 60

29 / 40 / 60

39 / 40 / 54

46 / 40 / 58

1,350

1,650

2,250

3,450

5,300

7,200

9,300

11,600

13,600

5S15-31

5S07-18

7S07-15

10S10-15

16S15-14

16S20-18

25S30-15

25S50-26

25S50-26

3.7 / 30 / 44

4.6 / 40 / 56

6.3 / 40 / 60

9.7 / 40 / 60

15 / 40 / 60

19 / 40 / 60

25 / 30 / 60

28 / 30 / 54

32 / 30 / 58

1,500

1,700

2,750

4,200

6,450

8,000

9,850

12,000

5S15-31

5S07-18

7S10-19

10S15-21

16S20-18

16S30-24

25S50-26

25S50-26

3.9 / 30 / 47

4.7 / 40 / 60

7.1 / 40 / 60

11 / 40 / 59

17 / 40 / 60

20 / 40 / 60

26 / 40 / 54

30 / 40 / 58

1,450

3,500

9,050

11,100

10S15-21

4,800
10S20-27

7,050

5S15-31

2,300
7S15-26

16S30-24

25S50-26

25S50-26

4.1 / 40 / 50

6.4 / 40 / 55

9.9 / 40 / 60

12 / 40 / 60

18 / 40 / 60

23 / 30 / 54

28 / 40 / 58

1,550

2,300

5,450

6,800

8,750

5S15-31

7S15-26

3,950
10S20-27

16S30-24

16S50-38

25S50-26

4.4 / 40 / 55

6.6 / 40 / 60

10 / 40 / 60

15 / 40 / 60

18 / 40 / 54

23 / 40 / 58

1,750

2,600

5,800

7,150

5S15-31

7S20-32

4,100
10S30-34

16S50-38

16S50-38

4.7 / 40 / 60

6.9 / 40 / 60

11 / 40 / 60

16 / 40 / 54

18 / 40 / 58

2,000

4,450
10S50-58DS

16S50-38

Pump Model GPM / Hp / Stages

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
Pump Model GPM / Hp / Stages
GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
200

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Array Rated Voltage

Gallons / Day
250

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
300

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
350

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
400

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Gallons / Day
500

speed and lower Gallons/Day production.


Selecting Modules
600

700

800

900

1000

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Definitions

Gallons / Day

Array Rated Power: The power of an array at it's peak power point under standard temperature conditions.

Pump Model GPM / Hp / Stages

Array Rated Voltage: The voltage of an array at the rated power point of the array (peak power point) under standard temperature conditions.

GPM Peak / Min. Hz Setting / Max. Speed

GPM: The rated flow rate of the pump in gallons per minute

Gallons / Day

Insolation: Amount of energy from the sun in a day hitting a surface tilted at an angle equal to the latitude.

Pump Model GPM / Hp / Stages

Sizing Software: AeroVironment developed software that predicts water delivery for given inputs, called USPC System Sizing Software.

5S20-39DS

3,350
10S30-34

GPM Peak / Min. Hz Setting / Max. Speed

Solar Noon: The time of day where the sun's intensity is the highest and where the array puts out the most power.

5.2 / 40 / 60

9.4 / 40 / 60

11 / 30 / 54

16 / 40 / 58

Gallons / Day

Total Dynamic Head (TDH): The sum of the static water level, discharge elevation, well draw down, and friction losses in the pipe and fittings.

1,650

2,050

5S20-39DS

5S30-48DS

3,850
10S50-58DS

4,650
10S50-58DS

4.6 / 40 / 60

Pump Model GPM / Hp / Stages


Assumptions used for table:

5.4 / 40 / 60

10 / 40 / 54

12 / 40 / 58

Gallons / Day

Insolation: 6kWh/m2 in March (peak insolation 875W/sqm).

1,900

Pump Model GPM / Hp / Stages

Latitude and Tilt: 30 degrees, Fixed array tilted 30 degrees.

5S30-48DS

3,600
10S50-58DS

4,350
10S50-58DS

GPM Peak / Min. Hz Setting / Max. Speed

PV Array: Rated power is discounted 5% for aging and soiling, and about 10% for temperature effects (cell temp 46C).

4.9 / 40 / 60

9.3 / 40 / 54

11 / 40 / 58

Gallons / Day

Low power operation: Minimum power required for flow is less than 1/4 the rated array power.

1,600

3,050

3,800

Pump Model GPM / Hp / Stages

Speed: Maximum pump speed is at least 40 Hz.

5S30-48DS

10S50-58DS

10S50-58DS

4.4 / 40 / 60

8.4 / 40 / 55

10 / 40 / 58

Sizing is DONE

GPM Peak / Min. Hz Setting / Max. Speed

Pumps: Grundfos submersible pumps used (Other pumps obtain similar results, for best results use Sizing Software).

Gallons / Day

Motor: Franklin 4", 3-phase 60 Hz

1100

6,250

GPM Peak / Min. Hz Setting / Max. Speed

* These pumps use a 1/3 Hp pump end with a 1/2 Hp 3 phase motor.

6" pumps

2520

25S05-3

Gallons / Day

150

subersible pumps listed.

2000

4,500

GPM Peak / Min. Hz Setting / Max. Speed

Adjusted Array Rated Power

** A surface pump is recommended in these locations. In Heads 30


feet or less, surface pumps will usually perform better than the

1540

10S03-6 *

Gallons / Day

125

Selecting PV modules needed uses the


Adjusted Array Rated Power calculated in
Step 7 and Array Rated Voltage found in Step 8.
First, divide Array Rated Voltage by Module
Rated Voltage to find number of modules in
series, (round up). Then divide Adjusted Array
Rated Power by the number of modules in
series to find Module Rated Power.
Example: Adjusted Array Rated Power = 1760 W,
Array Rated Voltage = 323VDC, Modules in
inventory 17.0VDC each. Divide 323 by 17.0 =
19 modules in series. Divide 1760W by 19
modules = 93W. Use 90 or 100 W modules.

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

At the top of the table (in the column above


selected Gallons/Day) is the Array Rated
Power needed for this system.

Example: If Max. Speed is 47Hz, Use an Array


Rated Voltage of 323 or 292VDC, (depending
on which voltage motor was selected). Voltage
can be higher than this (up to 400VDC, but
using a lower voltage will reduce maximum

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Array Rated Power

Max. Speed Motor V = 230V = 200/208V


60Hz
388VDC
350VDC
55Hz
356VDC
321VDC
50Hz
323VDC
292VDC
45Hz
291VDC
262VDC
40Hz
258VDC
232VDC

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

Pump Model

Using the Max. Speed for system selected, use


the table below to find Array Rated Voltage.

Step 9.

01/03/2000

(feet)

Selected Gallons/Day.

If the Insolation differs from the 6kWh/m 2


used in this table, multiply the Array Rated
Power found in Step 6 by the ratio of
2
(6kWh/m / actual Insolation).

Step 8.

HEAD

Go across table from the selected TDH to the


Gallons/Day that is nearest to the desired
Gallons/Day.
Under the selected Gallons/Day is the pump
model and system data. The GPM Peak is the
flow rate of system at solar noon. The Min. Hz
Setting is used in setting up the USPC, (this
eliminates unnecessary pump
operation when power is too low for flow).
The Max. Speed is the maximum speed the
pump reaches at solar noon.

Step 6.

USPC-5000

TOTAL DYN.

Select row that matches your TDH, (if TDH is


between values given, select greater TDH).

Step 4.

=== USPC-2000

Table to be used for approximating water delivered from system, for best results and to size single phase systems, use USPC System Sizing Software.

Determine Total Dynamic Head (TDH).


Determine Gallons/Day desired.
Selected TDH.

Pump Model GPM / Hp / Stages


GPM Peak / Min. Hz Setting / Max. Speed

3,600

=== USPC-2000

USPC-5000

10S50-58DS
9.4 / 40 / 58

You might also like