Professional Documents
Culture Documents
Edge Column
Edge Column
Edge Column
Sheet
C23
Load Cases
Load Case 1 Description DL ULS Shear Vt (kN) 1260 ULS X-moment (kNm) 10 ULS Y-moment (kNm) 10
BS8110 - 1997
Mty Y
675.00
X A
1012.50 1350.00 1687.50
Mtx
Job Number Job Title Software Consultants (Pty) Ltd Internet: http://www.prokon.com E-Mail : mail@prokon.com Client Calcs by Checked by Date
Sheet
Allowable shear stress (MPa) vc Shear force capacity Vc Effective shear force Veff (kN) (kN)
Shear reinforment should be placed in a band 1.5*d wide inside each critical perimeter. Maximum spacing 0.75*d.