You are on page 1of 1

JCI

Location: Monitor

JC International Limited
Technician: STANLEY IREHIE Equipment Name: CYGNUS 4 Date: 03/02/2012

RC 413243

Customer: Transocean Support Service.

12

Type Of Inspection: Ultrasonic thickness gauging Description: 5" High Pressure Line Engine Room

Material: Carbon Steel. System: REPORT NO. 64138


6

Inspection Location:

Clock Positions

Surface Condition: Coated

Test Point Location

Item

Pipe/ fittings Description

Original Thickness (mm)

Gauged Thk at Clock Positions (mm)

Mean(mm)

Particular Comments/ Surface Condition/ Recommendation

12

1a 1b 1c 2 3 4 5a 5b 5c 6 7 8
Comments:

elbow elbow elbow Pipe Pipe Pipe elbow elbow elbow Pipe Pipe Pipe

5" 5" 5" 5" 5" 5" 5" 5" 5" 5" 5" 5"

22.8 21.5 20.8 22.8 23.0 23.6 21.6 21.0 22.0 23.0 20.9 22.5 18.9 18.3 18.1 18.2 18.6 18.0 18.7 18.6 18.7 18.4 18.5 18.5 19.2 19.7 18.0 NRA 19.9 17.5 19.6 NRA 19.3 17.9 19.7 NRA 19.3 18.4 18.8 NRA 18.8 18.0 18.0 18.9 17.8 18.6 18.2 19.0

22.0 22.3 22.1 18.4 18.5 18.5

No visible defect found. No visible defect found. No visible defect found. No visible defect found. No visible defect found. No visible defect found. No visible defect found. No visible defect found. No visible defect found. No visible defect found.

18.4 18.4

No visible defect found. No visible defect found.

NOTE: NRA = NO READING ACCES