You are on page 1of 31

Boiler Design of innovative 600 C- and 700 C- Power Plants

Power Plants Technology in Dialogue 22th April 2008, Power Plant Technology, Hannover

Liisa Menp, Hitachi Power Europe GmbH l_maeenpaeae@hitachi-power.com

Boiler Design of innovative 600 C- and 700 C- Power Plants

Introduction 600 C - and 700 C - Technology

Design Aspects

Material selection

Conclusion Z
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

CO2 Emissions of Power Plants with different Fuels


1600 1400
Average China Russia 2003

CO2 Emissions [g/kWh]

1200 1000 800 600 400 200 0 0.25 Average worldwide

Current Average EU15-countries

lignite (rhenish) BAT 600/620 C 700/720 C 1 RH


Bituminous coal (Average)

Gas
Source: Marheineke T., Krewitt W., Neubarth J., Friedrich R., Vo A. IER-Bd. 74, IER, University of Stuttgart, Germany, 2000

0.3

0.35

0.4

0.45

0.5

0.55

0.6

Net efficiency [-]

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

Further CO2 Reduction: Carbon Capture

CO2 Emissions

with current Technology Trend with improved Efficiency Plants

with CCS

2000

2020

2050

Efficiency is the fast track CCS achieves near Zero-Emission


Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

CO2 Emissions Increase of Power Plants with Bituminous coal by applying CCS

1600 1400

CO2 Emissions [g/kWh]

1200
+ 44 %

1000 800 600 400 200 0 0.25

Current Average EU15-countries BAT 600/620 C


+ 30 % Bituminous coal 700/720 C (Average) 1 RH

Source: Marheineke T., Krewitt W., Neubarth J., Friedrich R., Vo A. IER-Bd. 74, IER, University of Stuttgart, Germany, 2000

0.3

0.35

0.4

0.45

0.5

0.55

0.6

Net efficiency [-] Loss of efficiency is derived by Power demand for ASU and compression of CO2 for Oxyfuel
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

Boiler Design of innovative 600 C- and 700 C- Power Plants

Introduction 600 C - and 700 C - Technology

Design Aspects

Material selection

Conclusion

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

600 C - Technology: NRW Power Plant Study


Tower type RKW Vorzugsvariante 600 MW Turmkessel boiler Preferred Boiler Design 600 MW
Plant power outputAnlage 500 - 600 MW Bruttoleistung der (gross) 500 - 600 MW Efficiency (target) 45 47 % Zielwirkungsgrad 45 47 % (el, net) Steam conditions Dampfzustnde HP Turbineneintritt 285 bar / FD Turbine inlet 285 bar / 600 C600 C IP Turbine inlet 60 bar C Z Turbineneintritt 60 bar / 620 / 620 C

PS Moorburg A/B
2 x 820 MWel / 2 x 2088 t/h HP: 600 C / 276 bar a RH: 610 C / 51 bar a Time of commissioning: 2011/2012

PS Datteln
1100 MWel / 2939 t/h HP: 600 C / 285 bar RH : 620 C / 58 bar Time of commissioning : 2011

Walsum K. 10
1 x 790 MWel / 1 x 2143 t/h HP : 603 C / 290 bar a RH : 621 C / 75 bar a Time of commissioning : 2009

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

600 C - Technology: PS Datteln (1100 MW)


+ 121.5 m + 115.5 m

1100 MWel / 2939 t/h Benson steam generator


+ 80.0 m

Bituminous coal Design parameters: HP: 600 C / 285 bar RH: 620 C / 58 bar Time of commissioning: 2011 Efficiency: > 45.5 % (el, net)
+ 0.0 m
16946

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

600 C - Technology: Boiler materials Existing PP Today


= 45 47 % 285 bar / 600 C / 620 C

= 43 % 262 bar / 545 C / 562 C

1 21 oV1 MoV12 rM Cr C X20 X20

itic sten als Au eri P92 mat

44 rMo 13C

0 10 B1 VTi rMo 7C

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

700 C - Technology: Power Plant Study NRWPP700

Power Plant Study NRWPP700 500 MWel Efficiency (target) 50 % (el, net)

Preferred boiler design:


365 bar / 705 C / 720 C single reheat

Three different versions for boiler design: 365 bar / 705 C / 720 C, single reheat 260 bar / 705 C / 720 C, single reheat 365 bar / 702 C / 720 C / 720 C, double reheat

Base for current design of first 700 C boiler.

Source: NRW Power Plant 700C (NRWPP700)


Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

10

700 C - Technology: steam generator for 500 MWel

HP-Part: Life steam pressure Life steam temperature

365 bar 705 C

RH-Part: Inlet pressure Outlet temperature

74 bar 720 C

Bituminous coal Benson steam generator First 700 C - Power Plant scheduled for: 2014 (E.ON)

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

11

700 C - Technology: Boiler materials Existing PP Today


= 45 47 % 285 bar / 600 C / 620 C

= 43 % 262 bar / 545 C / 562 C

2014
= 50 % 365 bar / 705 C / 720 C

1 21 oV1 MoV12 rM Cr C X20 X20

itic sten als Au eri P92 mat

se-ba ls Ni ia e- mater s a Ni-b rials e mat als, teri s ma itic aterial ns arte ase-m M Ni-b

44 rMo 13C

0 10 B1 VTi rMo 7C

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

12

Boiler Design of innovative 600 C- and 700 C- Power Plants

Introduction 600 C - and 700 C - Technology

Design Aspects

Material selection

Conclusion Z
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

13

Component design in the creep regime Tools / Methods


Design based on formula which are being defined by empirical knowledge

Current-State
Demand for 700 C - Technology cannot be satisfied using the existing design methods.

serf

p di 2 zul p

Perspectives
New methods for the design of high temperature components: European Pressure Equipment Directive (PED) allows the use of Design by Analysis (DBA)-Methods. For components operating in the creep regime the inelastic Finite Element Analyses have to be applied. Appropriate inelastic constitutive equations are necessary. Required research projects concerning inelastic constitutive equations have started.
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

14

HPE FEM Calculation of thick walled components


Example HP-Outlet header

Membranecreep 0,6 % 200.000 h

Wall thickness: Calculation acc. EN 12952-3: s=100 mm FEM: s= 77 mm


local creep max. 3,9 % at 200.000 h

s = 77 mm

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

15

Life time expectancy of superheater tubes

Reduction of life time of superheater tubes by: - creep - fire side corrosion - steam side oxidation

Each of the three mechanisms affects the others. Isolated consideration is not possible.

Calculation program to estimate the life time of superheater tubes considering all three influencing factors.

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

16

Examples Different materials

100 90
expended life time [%]

80 70 60 50 40 30 20 10 0 0

TP347H FG

Super304H not shot peened

200000

400000 time [h]

600000

800000

1000000

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

17

Examples Different materials

100 90
expended life time [%]

80 70 60 50 40 30 20 10 0 0

TP347H FG

Super304H not shot peened

HR3C

Super304H shot peened


200000 400000 time [h] 600000 800000 1000000

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

18

Examples Variations for design of superheater tubes

100 90
expended life time [%]

Flue gas temperature imbalances Steam temperature imbalances

80 70 60 50 40 30 20 10 0 0

Manufacturing tolerances

Design parameters

200000

400000

600000 time [h]

800000

1000000

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

19

Boiler Design of innovative 600 C- and 700 C- Power Plants

Introduction 600 C - and 700 C - Technology

Design Aspects

Material selection

Conclusion Z
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

20

Material selection superheater and reheater tubes


105 h creep strength (mean values) in MPa 300

250

er Pl an ts

200

Sanicro 25 Alloy 617 expected modified Super 304H

150

100

50

ferritic materials

Ex is tin

Po w

7CrMoVTiB10-10 16Mo3 13CrMo4-5

austenitic materials

DMV 310N HR3C

0 460 480 500 520 540 560

580

600

620

640

660

680

700

720

740

temperature C
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

21

Material selection superheater and reheater tubes


105 h creep strength (mean values) in MPa 300

250

er Pl an ts
ferritic materials

200

Sanicro 25 Alloy 617 expected modified

150

60 0

100

Po w

Super 304H

50

7CrMoVTiB10-10 16Mo3 13CrMo4-5

austenitic materials

DMV 310N HR3C

0 460 480 500 520 540 560

580

600

620

640

660

680

700

720

740

temperature C
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

22

Material selection superheater and reheater tubes


105 h creep strength (mean values) in MPa 300

250
Sanicro 25 Alloy 617 expected modified Super 304H

200

150

50

ferritic materials

7CrMoVTiB10-10 16Mo3 13CrMo4-5

70 0

100

C
austenitic materials

Po w

er Pl an ts
DMV 310N HR3C

0 460 480 500 520 540 560

580

600

620

640

660

680

700

720

740

temperature C
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

23

Material selection fire side corrosion


0.8
corrosion rate [mm/10.000 h]

0.7 0.6 600 C Technology 0.5 0.4 0.3 0.2 0.1 0 580 590 600 610 620 630 material temperature [C] 640
a eg flu em st p tu era re

00 14

00 12

C 00 10 C 800

650

660

Corrosion rate of austenitic materials with 18 % chromium


Source: Cutler, A.J.B., Flatley, T and Hay, K.A.: Fire-side corrosion in power-station boilers. Combustion (Dez. 1980) S. 17-25

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

24

Material selection fire side corrosion


0.8
corrosion rate [mm/10.000 h]

0.7 0.6 700 C Technology 0.5 0.4 0.3 0.2 0.1 0 580 590 600 610 620 630 material temperature [C] 640
a eg flu em st p tu era re

00 14

00 12

C 00 10 C 800

650

660

Corrosion rate of austenitic materials with 18 % chromium


Source: Cutler, A.J.B., Flatley, T and Hay, K.A.: Fire-side corrosion in power-station boilers. Combustion (Dez. 1980) S. 17-25

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

25

Material selection - membrane walls


Materials for 600C - Power Plant: 13CrMo4-5 (T1) 10CrMo9-10 (T11) 7CrMoVTiB10-10 (T24)

Ferritic

Possible additional materials for 700C - Power Plant: VM12-SHC X10CrWMoVNb9-2 (T92) Alloy 617 (modified)
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

Martensitic Nickel base alloy


26

Material selection superheater and reheater


Materials for 600C - Power Plant: Ferritic materials like 7CrMoVTiB10-10 (T24) X20CrMoV12-1, VM12-SHC TP 347H FG SP Super 304 H SP HR3C

Martensitic

Austenitic

Possible additional materials for 700C Power Plant: Sanicro 25 HR6W Alloy 617 (modified) Alloy 740, Alloy 263
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

Austenitic Nickel base alloys


27

Material selection - headers and pipes


Materials for 600C - Power Plant: X20CrMoV12-1 X10CrMoVNb9-1 (P91) X11CrMoWVNb9-1-1 (E911) X10CrWMoVNb9-2 (P92)

Martensitic

Possible additional materials for 700C Power Plant: Alloy 617 (modified) Alloy 263 HR6W
Liisa Menp / HPE Power Plants Technology in Dialogue, Hannover, 22th April 2008

Nickel base alloys Austenitic


28

Boiler Design of innovative 600 C- and 700 C- Power Plants

Introduction 600 C - and 700 C - Technology

Design Aspects

Material selection

Conclusion

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

29

Conclusion
600 C - boiler 700 C - boiler Biggest innovation of 700 C boiler lies in the materials ! New materials with higher strength and corrosion/ oxidation resistance needed. Highest grade for materials are the nickel base alloys.

Common for both boilers: FEM-Calculations for thick walled components Calculation program for life time expectancy of superheater tubes

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

30

Liisa Menp / HPE

Power Plants Technology in Dialogue, Hannover, 22th April 2008

31

You might also like