You are on page 1of 2

MIXFLOW LW

Light weight foam concrete admixture


Mixflow LW is a light weight concrete used for producing light weight, insulating roof screed giving drainage falls and providing a finish suitable to fixing a waterproofing membrane. Mixflow LW can be used for a variety of applications in addition to roof screeds. Mixflow LW is a stable cellular concrete 3 3 building chemical formulation having a density of 300kg/m to 750kg/m (depending on application). Mixflow LW consist of a honeycomb of concrete enclosing a system of small, regular, strong - walled air cells, which are not connected internally so it can resist the absorption of water easily. Tests are shown the importance of small and regular cells in producing a lightweight concrete of high strength combined with lightness and good thermal insulation properties. Appropriation Considering as thermal insulating material Mixflow LW will not decay or burn, or to be subject to vermin attack. The graphs showing thermal conductivity values and crushing Strength in relation to density is given under properties of Mixflow LW lightweight concrete. Mixflow LW is mainly using for the following areas Floor screeds under rigid floor finishes Pipe line and culvert insulation Cold store insulation Concrete panels & sandwich panel Technical properties Appearance: Light yellow liquid 0 Specific gravity: 1.1@20 c Chloride content: Nil Nitrate content: Nil Solubility in water: infinite 0 Freezing point: Less than 0 c Flash point: None

THE CONSTRUCTION CHEMIST

Product Management Approximate quantity: 3 650-750kg/m for spectator roofs, terraces, balconies 3 500kg/m for flat roofs which are subject to maintenance traffic only 3 400kg/m for filling of ducts, pipeline, where no direct load is not coming

FAB
3

Mix design: Water: clean fresh water 0 Cement: OPC Cement, quick setting cement may be used in cold conditions, ie +5 C or below 3 Mixflow LW: 1.3kg / m Sand: Clean sharp sand as used for good quality mortar Note: Detailed mix designs are shown in the above chart - mix designs for various densities / m - The amount of Mixflow LW used is subject to slight variations owed to differences in the hardness of the local water supply and the properties of the cement. There is any variation in a larger way of using Mixflow LW occurred where water supplies are polluted or by using cement from old stock. Therefore it is very important to make sure the supply of water and cement must be fresh and clean and from new stock respectively to produce the Mixflow LW Light weight concrete economically. Water cement ratio is very important due to its effect on the quality of foam concrete. The compressive resistance of the foam concrete is also determined by the homogeneous distribution of the pores. The more even the distribution and smaller the pores, the better compressive strength. The homogeneity is again a function of the consistency and thus of the water ratio

MIXFLOW LW
Light weight foam concrete admixture
Crushing strength Density 300 400 500 600 650 Thermal conductivity Density 300 400 500 600 650 Kg/sq. cm 5 10 17 25 14 only cement only cement only cement only cement 290 kg cement+300 kg sand

kcal./ m / h / c 0.062 0.08 0.09 0.11

Mix designs of Mixflow LW Light weight concrete under various densities/m Density 3 Kg/m 300 400 500 600 650 water ltr 3 kg/m kg 62.5 165 210 250 230

FAB
3

Mixflow LW 1.300 1.250 1.180 1.100 1.180

Cement kg 250 330 420 500 290

Sand 300

Net weight 10ltr 3.1 4.9 6.3 7.5 8.2

Quality Mixflow LW 3 Ltr.m 1.3 1.2 1.2 1.1 1.1

THE CONSTRUCTION CHEMIST

Packing & Storage Up to 12 months in manufactures sealed containers stored in a cool dry place away from high temp. Available in 200 litres drums. Reseal the container after use and ensure product is stored as instructed on the label. Mixflow LW should be stored in cool, shaded warehouses. Mixflow LW should be stored in cool, shaded warehouses. Shelf life is 12 months Health & Safety Mixflow LW contains no hazardous substances; however it should not be allowed to come into contact with skin and eyes. Wear suitable protective gloves and goggles whilst handling. When in contact with the skin and eyes, wash thoroughly and immediately with warm water. If swallowed seek medical attention. For more details, please refer to the MSDS released on each PyChem product
Rev. Nov-10/01 Technical information given in this datasheet is true and exact to the best of our knowledge, laboratory upshot and hands-on application. The datasheets of all products are revised/updated regularly and hence ensure that the latest release is used for reference and recommendation. The date of the publishing is as in this sheet. All data are mean of numerous tests, assessment and analysis conducted under laboratory ambiance. Climatic disparity in temperature, humidity, etc. and porosity of substrate may impinge on the values. Group Head office: PYCHEM Co. L L C Post Box 23940, Sharjah. Te: +971 6 5420414 / 5431636 Fax: +971 6 5421446 Mail: mail@fab-cc.com fabchem@gmail.com Under Technical Collaboration with MIX UK Limited Cherry Tree House, Cherry Tree Lane Rostherne, Cheshire,WA143RZ Web: www.mixuk.com Head office: T33A/1, Thryambhava Houses Kalapetty road,Coimbatore 14 Tel: 0422 3222245 Fax: 0422 2625207 Mail: mail@fab-cc.com fabchem@gmail.com