You are on page 1of 17

Search Explore Download 0 Comment Link Embed Zoom of 215 Readcast 0inShare H an dover Da ta l Basic Handover Parameters l HO Control

l Cell HO Data l Concentric Data l Filter/Penalty Data l Emergency HO Data l UTRAN FDD HO Data l UTRAN TDD HO Data l Fast HO Parameters l Enhance dual band data l 2G BA2 Table l UTRAN FDD CELL BA2 l UTRAN TDD CELL BA2

Parent topic: Cell Parameters Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd. Basic Han do ver Parameters l HO Control Switch l TA HO Watch Time(Num of MR)(0.5s) l TA HO Valid Time(0.5s) l BQ HO Watch Time(0.5s) l BQ HO Valid Time(0.5s) l HCS HO Watch Time(0.5s) l HCS HO Valid Time(0.5s) l Interfere HO Static Time(0.5s) l Interfere HO Valid Time(0.5s) l Better Cell Handover Enable l Better Cell HO Watch Time(s) l Better Cell HO Valid Time(s) l IntraCell AMR TCHF-TCHH Ho Allowed l IntraCell AMR TCHF-TCHH Traffic Threshold l IntraCell TCHF-TCHH Ho Duration(s) l IntraCell TCHF-TCHH Ho Period(s) l IntraCell AMR TCHF-TCHH Ho Pathloss Adjust Step l IntraCell AMR TCHF-TCHH Ho ATCB Adjust Step l IntraCell AMR TCHF-TCHH Ho Pathloss Threshold l IntraCell TCHF-TCHH Pathloss Offset Overlay l IntraCell AMR TCHF-TCHH Ho ATCB Threshold

l IntraCell TCHF-TCHH ATCB Offset Overlay l IntraCell AMR TCHF-TCHH Ho Qual. Threshold l IntraCell TCHF-TCHH Ho Stat Time(s) l IntraCell TCHF-TCHH Ho Last Time(s) l IntraCell AMR TCHH-TCHF Traffic Threshold l IntraCell AMR TCHH-TCHF Qual Ho Allowed l IntraCell TCHH-TCHF Ho Duration(s) l IntraCell AMR TCHH-TCHF Ho ATCB Threshold Page 1 of 215Handover Data2010-06-10file://C:\Documents and Settings\a\Local Settings\Temp\~hhD44.htmPDF "pdfFactory Pro" www.fineprint.cn

l IntraCell TCHH-TCHF ATCB Offset Overlay l IntraCell AMR TCHH-TCHF Ho Pathloss Threshold l IntraCell TCHH-TCHF Pathloss Offset Overlay l IntraCell AMR TCHH-TCHF Ho Qual. Threshold l IntraCell TCHH-TCHF Ho Stat Time(s) l IntraCell TCHH-TCHF Ho Last Time(s) l IntraCell Non-AMR TCHF-TCHH Ho Allowed l IntraCell Non-AMR TCHF-TCHH Traffic Threshold l IntraCell Non-AMR TCHF-TCHH Ho Pathloss Adjust Step l IntraCell Non-AMR TCHF-TCHH Ho ATCB Adjust Step l IntraCell Non-AMR TCHF-TCHH Ho Pathloss Threshold

l IntraCell Non-AMR TCHF-TCHH Ho ATCB Threshold l IntraCell Non-AMR TCHF-TCHH Ho Qual. Threshold l IntraCell Non-AMR TCHH-TCHF Traffic Threshold l IntraCell Non-AMR TCHH-TCHF Qual. Ho Allowed l IntraCell Non-AMR TCHH-TCHF Ho ATCB Threshold l IntraCell Non-AMR TCHH-TCHF Ho Pathloss Threshold l IntraCell Non-AMR TCHH-TCHF Ho Qual. Threshold l Inter-RAT Out BSC Handover Enable l Inter-RAT In BSC Handover Enable l Inter-RAT Cell Reselection Enable l Pathloss Ho. Enable l Co-BSC/MSC Adj l SDCCH HO Allowed l Intracell HO Allowed l Intracell F-H HO Allowed l Load HO Allowed l MS Fast Moving HO Allowed l Rx_Level_Drop HO Allowed l PBGT HO Allowed l Level HO Allowed l Edge Handover Allowed l BQ HO Allowed l TA HO Allowed

l Concentric Circles HO Allowed l Interference HO Allowed l Edge HO UL RX_LEV Threshold l Edge HO DL RX_LEV Threshold l Edge HO Watch Time(s) l Edge HO Valid Time(s) l Edge HO Watch Time(0.5s) l Edge HO Valid Time(0.5s) l Edge HO AdjCell Watch Time(s) l Edge HO AdjCell Valid Time(s) l Edge HO AdjCell Watch Time(0.5s) l Edge HO AdjCell Valid Time(0.5s) l Layer HO Watch Time(s) l Layer HO Valid Time(s) l PBGT Watch Time(s) l PBGT Valid Time(s) l Intracell F-H HO Stat Time(s) l Intracell F-H HO Last Time(s) l F2H HO Threshold l H2F HO Threshold Page 2 of 215Handover Data2010-06-10file://C:\Documents and Settings\a\Local Settings\Temp\~hhD44.htmPDF "pdfFactory Pro" www.fineprint.cn

l Inter-layer HO Threshold l Inter-layer HO Hysteresis l Min UP Power on HO Candidate Cell l Min DL Power on HO Candidate Cell l Quick Handover Enable l TIGHT BCCH HO Watch Time(s) l TIGHT BCCH HO Valid Time(s) l ATCBHoSwitch l Enhanced Concentric Allowed Parent topic: Handover Data Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd. H O Con trol Sw itch Parent topic: Basic Handover Parameters Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd. TA H O Watch T ime( Nu m of MR)(0.5s) Parameter Name HO Control Switch Description This parameter specifies whether HO Algorithm I or HO Algorithm II isvalid. GUI Value Range [HO Algorithm I, HO Algorithm II] Default Value HO Algorithm I Unit None Step Modification Rules None ConfigurationPolicy None RecommendedValue HO Algorithm I ParameterRelationship None BSC Feature None Parameter Class Parameters About Radio Resources Caution None Parameter Name TA HO Watch Time(Num of MR)(0.5s)

Description The P/N criterion must be met for triggering a TA handover. That is, the Page 3 of 215Handover Data2010-06-10file://C:\Documents and Settings\a\Local Settings\Temp\~hhD44.htmPDF "pdfFactory Pro" www.fineprint.cn

Parent topic: Basic Handover Parameters Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd. TA H O V alid T ime( 0.5s) TA handover can be triggered only if P measurement reports among Nmeasurement reports meet the triggering conditions. Every 0.48s ameasurement report is submitted. Therefore, the unit is 0.5s.This parameter corresponds to N in the P/N criterion. GUI Value Range [1,16] Default Value 1 Unit Seconds Step 0.5s Modification Rules None ConfigurationPolicy None RecommendedValue 1 ParameterRelationship None BSC Feature None Parameter Class Parameters About Radio Resources Caution This parameter is valid only when the HO Control Switch is set to HOAlgorithm II. This parameter is invalid when the HO Control Switch isset to HO Algorithm I. Parameter Name TA HO Valid Time(0.5s) Description The P/N criterion must be met for triggering a TA handover. That is, theTA handover can be triggered only if P measurement reports among Nmeasurement reports meet the triggering conditions. Measurementreports are submitted every 0.48s. Therefore, the unit here is set to 0.5s.This parameter corresponds to P in the P/N criterion. GUI Value Range [1,16] Default Value 1 Unit Seconds Step 0.5s Modification Rules None Configuration None Page 4 of 215Handover Data2010-06-10file://C:\Documents and Settings\a\Local Settings\Temp\~hhD44.htmPDF "pdfFactory Pro" www.fineprint.cn

RSCP Threshold for Better 3G Cell HO for Handover Parameter

Download or Print Add To Collection 5.3K READS 6 READCASTS 7 EMBED VIEWS

Published by bluelife84

Follow

Search TIP Press Ctrl-F to search anywhere in the document. Sections

Handover Data Basic Handover Parameters HO Control Switch TA HO Watch Time(Num of MR)(0.5s) TA HO Valid Time(0.5s) BQ HO Watch Time(0.5s) BQ HO Valid Time(0.5s) HCS HO Watch Time(0.5s) HCS HO Valid Time(0.5s) Interfere HO Static Time(0.5s) Interfere HO Valid Time(0.5s) Better Cell Handover Enable Better Cell HO Watch Time(s)

Better Cell HO Valid Time(s) IntraCell AMR TCHF-TCHH Ho Allowed IntraCell AMR TCHF-TCHH Traffic Threshold IntraCell TCHF-TCHH Ho Duration(s) IntraCell TCHF-TCHH Ho Period(s) IntraCell AMR TCHF-TCHH Ho Pathloss Adjust Step IntraCell AMR TCHF-TCHH Ho ATCB Adjust Step IntraCell AMR TCHF-TCHH Ho Pathloss Threshold IntraCell TCHF-TCHH Pathloss Offset Overlay IntraCell AMR TCHF-TCHH Ho ATCB Threshold IntraCell TCHF-TCHH ATCB Offset Overlay IntraCell AMR TCHF-TCHH Ho Qual Threshold IntraCell TCHF-TCHH Ho Stat Time(s) IntraCell TCHF-TCHH Ho Last Time(s) IntraCell AMR TCHH-TCHF Traffic Threshold IntraCell AMR TCHH-TCHF Qual Ho Allowed IntraCell TCHH-TCHF Ho Duration(s) IntraCell AMR TCHH-TCHF Ho ATCB Threshold IntraCell TCHH-TCHF ATCB Offset Overlay IntraCell AMR TCHH-TCHF Ho Pathloss Threshold IntraCell TCHH-TCHF Pathloss Offset Overlay IntraCell AMR TCHH-TCHF Ho Qual Threshold IntraCell TCHH-TCHF Ho Stat Time(s) IntraCell TCHH-TCHF Ho Last Time(s) IntraCell Non-AMR TCHF-TCHH Ho Allowed IntraCell Non-AMR TCHF-TCHH Traffic Threshold IntraCell Non-AMR TCHF-TCHH Ho Pathloss Adjust Step IntraCell Non-AMR TCHF-TCHH Ho ATCB Adjust Step IntraCell Non-AMR TCHF-TCHH Ho Pathloss Threshold IntraCell Non-AMR TCHF-TCHH Ho ATCB Threshold IntraCell Non-AMR TCHF-TCHH Ho Qual Threshold IntraCell Non-AMR TCHH-TCHF Traffic Threshold IntraCell Non-AMR TCHH-TCHF Qual. Ho Allowed IntraCell Non-AMR TCHH-TCHF Ho ATCB Threshold IntraCell Non-AMR TCHH-TCHF Ho Pathloss Threshold IntraCell Non-AMR TCHH-TCHF Ho Qual Threshold Inter-RAT Out BSC Handover Enable Inter-RAT In BSC Handover Enable Inter-RAT Cell Reselection Enable Pathloss Ho. Enable Co-BSC/MSC Adj SDCCH HO Allowed Intracell HO Allowed Intracell F-H HO Allowed Load HO Allowed

MS Fast Moving HO Allowed Rx_Level_Drop HO Allowed PBGT HO Allowed Level HO Allowed Edge Handover Allowed BQ HO Allowed TA HO Allowed Concentric Circles HO Allowed Interference HO Allowed Edge HO UL RX_LEV Threshold Edge HO DL RX_LEV Threshold Edge HO Watch Time(s) Edge HO Valid Time(s) Edge HO Watch Time(0.5s) Edge HO Valid Time(0.5s) Edge HO AdjCell Watch Time(s) Edge HO AdjCell Valid Time(s) Edge HO AdjCell Watch Time(0.5s) Edge HO AdjCell Valid Time(0.5s) Layer HO Watch Time(s) Layer HO Valid Time(s) PBGT Watch Time(s) PBGT Valid Time(s) Intracell F-H HO Stat Time(s) Intracell F-H HO Last Time(s) F2H HO Threshold H2F HO Threshold Inter-layer HO Threshold Inter-layer HO Hysteresis Min UP Power on HO Candidate Cell Min DL Power on HO Candidate Cell Quick Handover Enable TIGHT BCCH HO Watch Time(s) TIGHT BCCH HO Valid Time(s) ATCBHoSwitch Enhanced Concentric Allowed HO Control Min Interval for TCH HOs Min Interval for SDCCH HOs Min Interval for Consecutive HOs Min Interval for Emerg.HOs Inter-BSC SDCCH HO ALLowed Penalty Allowed MR.Preprocessing Transfer Original MR

Transfer BS/MS Power Class Sent Freq.of preprocessed MR Min Power Level For Directed Retry Cell HO Data DLevOffset For Interfere HO(dbm) DQualOffset For Interfere HO ULevOffset For Interfere HO(dbm) UQualOffset For Interfere HO Inter-RAT Load Handover Allowed Inter-BSC Load Handover Allowed UL BQ HO Watch Time(0.5s) UL BQ HO Last Time(0.5s) System Flux Threshold for Load HO Load HO Threshold(%) Load Req.on Candidate Cell(%) Load HO Bandwidth Load HO Step Period Load HO Step Level MS Fast-moving Watch Cells MS Fast-moving Valid Cells MS Fast-moving Time Threshold MAX Consecutive HO Times Forbidden time after MAX Times Interval for Consecutive HO Jud Penalty on Fast Moving Handover Penalty Time on Fast Moving HO(s) UL Expected Level at HO Access K Offset RX_QUAL Threshold for TIGHT BCCH HO Load Threshold for TIGHT BCCH HO Max Resend Times of Phy.Info T3105(10ms) Concentric Data IniLev For EnUtoO Load HO UL to OL HO Allowed OL to UL HO Allowed RX_LEV for UO HO Allowed RX_QUAL for UO HO Allowed TA for UO HO Allowed UO Signal Intensity Difference RX_LEV Threshold RX_LEV Hysteresis RX_QUAL Threshold TA Threshold TA Hysteresis

UO HO Watch Time(s) UO HO Valid Time(s) Assign Optimum Layer Assign-optimum-level Threshold TA Threshold of Assignment Pref TA Pref. of Imme-Assign Allowed TA Threshold of Imme-Assign Pref Pref. Subcell in HO of Intra-BSC Incoming-to-BSC HO Optimum Layer OtoU HO Received Level Threshold UtoO HO Received Level Threshold UtoO Traffic HO Allowed Underlay HO Step Period(s) Underlay HO Step Level Penalty Time of UtoO HO(s) Penalty Time after UtoO HO Fail(s) Penalty Time after OtoU HO Fail(s) MaxRetry Time after UtoO Fail En Iuo Out Cell Low Load Threshold En Iuo Out Cell General OverLoad Threshold En Iuo Out Cell Serious OverLoad Threshold En Iuo In Cell Load Classification HO Period En Iuo In Cell Load Classification HO Step ReceiveQualThrshAMRFR ReceiveQualThrshAMRHR Ps OtoU HO Received Level Threshold Ps UtoO HO Received Level Threshold Filter/Penalty Data Penalty Time on Load HO Penalty Value on Load HO Penalty Time on Interfere HO NCell Filter Length for SDCCH Level TA Filter Length for SDCCH Level Allowed M.R Number Lost Filter Length for TCH Level Filter Length for TCH Qual Filter Length for SDCCH Level Filter Length for SDCCH Qual Filter Length for Ncell RX_LEV Filter Length for TA Penalty Level after HO Fail Penalty Level after BQ HO Penalty Time after BQ HO(s) Penalty Level after TA HO Penalty Time after TA HO(s)

Filter Length for SDCCH MEAN_BEP Filter Length for TCH MEAN_BEP Filter Length for SDCCH CV_BEP Filter Length for TCH CV_BEP Filter Length for SDCCH REP_QUANT Filter Length for TCH REP_QUANT Penalty Time after AMR TCHF-H HO Fail(s) Filter Length for SDCCH NBR_RCVD_BLOCK Filter Length for TCH NBR_RCVD_BLOCK RscPenaltyTimer UmPenaltyTimer CfgPenaltyTimer DtxMeasUsed Emergency HO Data Emergency HO TA Threshold DL Qual. Threshold UL Qual. Threshold Filter Parameter A1 Filter Parameter A2 Filter Parameter A3 Filter Parameter A4 Filter Parameter A5 Filter Parameter A6 Filter Parameter A7 Filter Parameter A8 Filter Parameter B No Dl Mr.HO Allowed No Dl Mr.Ul Qual HO Limit Cons.No Dl Mr.HO Allowed Limit RXQUAL1 RXQUAL2 RXQUAL3 RXQUAL4 RXQUAL5 RXQUAL6 RXQUAL7 RXQUAL8 RXQUAL9 RXQUAL10 RXQUAL11 RXQUAL12 RXLEVOff DLQuaLimitAMRFR ULQuaLimitAMRFR DLQuaLimitAMRHR

ULQuaLimitAMRHR UTRAN FDD HO Data Inter-RAT HO Preference HO Preference Threshold for 2G Cell RSCP Threshold for Better 3G Cell HO Ec/No Threshold for Better 3G Cell HO 3G Better Cell HO Watch Time(s) 3G Better Cell HO Valid Time(s) Better 3G Cell HO Allowed UTRAN TDD HO Data TDD Inter-RAT HO Preference TDD HO Preference Threshold for 2G Cell TDD RSCP Threshold for Better 3G Cell HO TDD 3G Better Cell HO Watch Time(s) TDD 3G Better Cell HO Valid Time(s) TDD Better 3G Cell HO Allowed Fast HO Parameters Quick Handover Up Trigger Level(dB) Quick Handover Down Trigger Level(dB) Quick Move Speed Threshold(m/s) Quick Handover Static Time(0.5s) Quick Handover Last Time (0.5s) Serving Cell Filter Length MR Number Neighbor Cell Filter Length MR Number Number of Ignored Measurement Reports Quick Handover Punish Time(s) Quick Handover Punish Value(dB) Quick Handover Offset(dB) Enable Quick PBGT HO Algorithm When MS Leaves BTS Enhance dual band data UL Subcell Lower Load Threshold(%) Assignment Optimization of UL Subcell Allowed Or Not Assignment Optimization of OL Subcell Allowed Or Not UL Subcell General Overload Threshold(%) UL Subcell Serious Overload Threshold(%) Allowed Flow Control Level of UL And OL Subcell HO Distance Between Boundaries of UL And OL Subcells(dB) Distance Hysteresis Between Boundaries of UL And OL Subcells(dB) Load HO From UL Subcell to OL Subcell Allowed UL Subcell Load Hierarchical HO Period(s) Step Length of UL Subcell Load HO(dB) Modified Step Length of UL Load HO Period (s) Load HO of OL Subcell to UL Subcell Enabled OL Subcell Load Diversity HO Period(s)

Step Length of OL Subcell Load HO(dB) Incoming OL Subcell HO level Threshold(dB) Outgoing OL Subcell HO level Threshold(dB) Inter UL And OL Subcells HO Penalty Time (s) Total Number of Measurements(s) Number of Satisfactory Measurements(s) Inner Cell EDGE HO Enable Inner Cell Serious OverLoad Threshold(%) 2G BA2 Table UTRAN FDD CELL BA2 UTRAN TDD CELL BA2

Info and Rating Category: Uncategorized. Rating: Upload Date: 08/08/2011 Copyright: Attribution Non-commercial Tags: This document has no tags. Free ebook download as PDF File (.pdf), text file (.txt) or read book online for free. Flag document for inapproriate content More From This User

143 p. UMTS Handover bluelife84 40 Reads

6 p. Commissioning Node B HUAWEI bluelife84 173 Reads

9 p. Utf 8 Erlang Table bluelife84 31 Reads Next

Related

13 p. Load HO Allowed tejendra184066 424 Reads

495 p. WCDMA RAN Planning and Optimization Features and Algorithms mohd_monir 1213 Reads

100 p. Hand Over Faraz Husain 781 Reads Next Leave a Comment

Submit Characters: 400

About

About Scribd Blog Join our team! Contact Us

Advertise with us Get started AdChoices Support Help FAQ Press

Partners Publishers Developers / API Legal Terms Privacy Copyright Copyright 2012 Scribd Inc. Language: English

You might also like