Confidentiality:
Contents
Relevant Process/Regulation ............................................................... 1 1 2 Abstract ............................................................................. 3 Purpose .............................................................................. 3
Operating Instructions ................................................................... 4 2.1 2.2 2.3 2.4 2.5 2.6 2.7 3 4 5 6 7 Link Balance Equations:.......................................................... 4 Counters used for path-balance Judgment .......................................... 4 Judgment Criteria................................................................ 6 Normal Trend for Path-Balance .................................................... 6 Weak DL Trend for Path-Balance ................................................... 7 Weak UL Trend for Path-Balance ................................................... 8 Misleading Case for Path-Balance ................................................. 9
Appendix ............................................................................ 10 Support Document(s) ................................................................. 10 Related Document(s) ................................................................. 10 Record Retention .................................................................... 10 Document Preparation/Modification Record ............................................ 10
2013-11-11
Huawei Confidential
Page 2 of 10
Confidentiality:
1 Abstract
This document instructs engineers how to perform the Base Band Hopping audit.
2 Purpose
This document aims to standardize the operation procedure of Path-Balance Judgment
1. 2. 3. 4. 5. 6. 7.
Link balance Equations Counters used for path-balance Judgment Judgment Criteria Normal Balance Trend Weak UL Trend Weak DL Trend Misleading Case
2013-11-11
Huawei Confidential
Page 3 of 10
Confidentiality:
Operating Instructions
2.1 Link Balance Equations: UL/DL Path balance difference = UL path loss - DL path loss = (MS real transmit power-UL Rx_Lev) - (BTS cabinet output power-DL Rx_Lev). BTS cabinet output power=TRX power-static power class*2 + Power fine tuning Combiner loss - DL dynamic PC level*2 + dynamic PBT gain
2.2
The below counters define the balance status of the TRX into 11 levels and the balance should be around level 6 The levels below level 6 indicates the status of the UL The levels above level 6 indicates the status of the DL Level 1 Indicates that the UL > DL by 15 Level 1 Indicates that the DL > UL by 15
2013-11-11
Huawei Confidential
Page 4 of 10
Confidentiality:
BSC 6900 TRX Level Balance Counters S462A:Number of MRs (Uplink-and-Downlink Balance Level = 1)(none) S462B:Number of MRs (Uplink-and-Downlink Balance Level = 2)(none) S462C:Number of MRs (Uplink-and-Downlink Balance Level = 3)(none) S462D:Number of MRs (Uplink-and-Downlink Balance Level = 4)(none) S462E:Number of MRs (Uplink-and-Downlink Balance Level = 5)(none) S462F:Number of MRs (Uplink-and-Downlink Balance Level = 6)(none) S462G:Number of MRs (Uplink-and-Downlink Balance Level = 7)(none) S462H:Number of MRs (Uplink-and-Downlink Balance Level = 8)(none) S462I:Number of MRs (Uplink-and-Downlink Balance Level = 9)(none) S462J:Number of MRs (Uplink-and-Downlink Balance Level = 10)(none) S462K:Number of MRs (Uplink-and-Downlink Balance Level = 11)(none)
UL/DL Path-balance Diffrence X <= -15 -14 < x < -11 -10 < x < -8 -7 < x < -5 -4 < x < -2 -1 < x < 1 2<x<4 5<x<7 8 < x < 10 11 < x < 14 X => 15 Comment UL > DL UL > DL UL > DL UL > DL UL > DL Balance DL > UL DL > UL DL > UL DL > UL DL > UL
2013-11-11
Huawei Confidential
Page 5 of 10
Confidentiality:
2.3
Judgment Criteria
The criteria used to judge if the TRX is Balance or not is as following: 1- `Shape of the graph should be centered on Level 6 2- Sum of Levels (1 + 2) should be Less Than 20 % from the total value of Levels 1 to 11 (around the 20 %) 3- Sum of Levels (10 + 11) should be Less Than 25 % from the total value of Levels 1 to 11 (around the 25 %)
2.4
The Normal Trend of the balance means that the measurement should be around level 6 as shown below
2013-11-11
Huawei Confidential
Page 6 of 10
Confidentiality:
2.5
Weak DL means that the measurement of the UL Level counters is higher than the DL counters (Levels 1+2 is Higher than 20 % from the total Measurement)
2013-11-11
Huawei Confidential
Page 7 of 10
Confidentiality:
2.6
Weak DL means that the measurement of the DL Level counters is higher than the UL counters (Levels 10+11 is Higher than 25 % from the total Measurement)
2013-11-11
Huawei Confidential
Page 8 of 10
Confidentiality:
2.7
In the below case the measurement of Levels 10+11 is 22% which is good and accepted but from the TRX chart we can see that the TRX suffers from Weak-UL status as shown below
So the conclusion from this case is that: 1- Percentage is just an indication to determine the worst cases 2- The judgment must be done for case by case specially for the TRXs with percentage around 20% for both UL/DL indicators (Levels 1+2 or Level 10+11)
2013-11-11
Huawei Confidential
Page 9 of 10
Confidentiality:
Appendix
Not Required
4
No. 1.
Support Document(s)
Document name Document code
Related Document(s)
Document Code
Record Retention
Hand over Owner Retention Owner Retention Location Filing Date Retention Period Disposition at Expiry
(Manda tory) Prepared/Modified Version By V1.00 Mostafa Ibrahim 701891 (Egypt 3 licence)