TIC QUADRANT 2200/ 2200 RC Diagnosis
Contents
CCU
08/2002 1
Diagnosis QUADRANT 2200/ 2200 RC TIC
Cutting frame Se r v i c e RC 8 2
angle W= 2 0 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A: 00000000 U: 11 , 6
F : 00000000 FFFF
2 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
1.2 Additional information about page "8/1 (Service 1)" (up to module 1 no. 835024.2)
(P=) Current pressure The pressure in the baling chamber cylinders is displayed here in bars.
(L) Current bale length The length of the bale in the baling chamber is displayed here in metres
to the second decimal point.
(N0=) PTO shaft speed The calculated PTO shaft speed in revolutions per minute is displayed
here (this speed is measured by the drive speed sensor).
(N1=) Feed rake speed The feed rake speed in revolutions per minute is displayed here
(150 rpm at 1000 rpm PTO shaft speed)
(N2=) Rotor speed The rotor speed in revolutions per minute is displayed here (140 rpm at
1000 rpm PTO shaft speed)
(U:) Voltage The supply voltage is displayed here in Volt to the first decimal point.
Key test A combination of characters and numbers is displayed here to test the
function of the keys on the Control Terminal.
(P0) Control unit P+ The condition of the baling pressure build-up valve is displayed here.
The displayed number is proportional with the valve actuation and may
assume values from 0 to 255.
0 = Valve not actuated
255 = Valve fully actuated
(P1) Control unit P- The condition of the baling pressure relief valve is displayed here. The
displayed number is proportional with the valve actuation and may
assume values from 0 to 255.
0 = Valve not actuated
255 = Valve fully actuated
(E:) Inputs The condition of various circuits connected with the modules is
displayed here. Each numeric character corresponds to one circuit.
0 = Circuit open
1 = Circuit closed
(A:) Outputs The condition of various circuits connected with the modules is
displayed here. Each numeric character corresponds to one circuit.
0 = Circuit open
1 = Circuit closed
(F:) Error Malfunctions are displayed here. Each numeric character corresponds
to one error.
0 = No error
1 = Error
1.3 Additional information about page "8/2 (Service RC)" (up to module 1 no. 835024.2)
(W=) Cutting frame angle The cutting frame angle in degrees is displayed here. The higher the
value, the wider the cutting frame is open.
08/2002 3
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345678
Eight numeric characters are available for input diagnosis in line “E”, each of them being assigned to one
circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
4 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e 1 8 1
P= 0L 0 , 00 N0 = 0
P0 0 N1 = 0
P1 0 N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
Eight numeric characters are available for output diagnosis in line “A” on page "8 / 1 (Service 1)" and page
"8 / 2 (Service RC)", each of them being assigned to one circuit. It must be ensured that the baling pressure
solenoid valves (P0 and P1) are not activated. To achieve this, press the "Plus key" once.
The numeric characters only indicate if a solenoid valve is actuated by the corresponding module.
For diagnosis purposes, the corresponding function must be activated, i.e. the functions can be
checked only one by one.
The numeric characters may assume the following values:
0 = Solenoid valve is not actuated by the module
or
1 = Solenoid valve is actuated by the module.
Dependencies and switching sequences which may occur in normal operation have an influence.
08/2002 5
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e RC 8 2
W= 20 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
6 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e 1 8 1
P= 0L 0 , 00 N0 = 0
P0 0 N1 = 0
P1 0 N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
To activate this function, keep the “Minus key” pressed while in the service menu, i.e. a maximum of
eight circuits may be checked at the same time.
Eight numeric characters are available for output diagnosis in line “A”, each of them being assigned to one
circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed and/or solenoid coil OK.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
08/2002 7
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345678
Eight numeric characters are available for error display in line “F”, each of them being assigned to one error.
This function is available only on page 8/1 "Service 1".
The numeric characters may assume the following values:
0 = No error or
1 = Error.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
8 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345
Four numeric characters are available for key testing in line (1) shown above.
Pushing a key on the Control Terminal produces one of the combinations of numbers and characters shown
below which allow checking the function.
The character “G” at the 5th digit indicates if the central lubrication system is currently active, otherwise this
digit remains free.
Example: When the central lubrication system is active and the “Minus” key is pressed, the numeric
characters read “FDFFG”. If the central lubrication system is not active and the “Minus key” is
pressed, the numeric characters read “FDFF”.
ROTOCUT knives ON B F F F
Minus F D F F
Plus F F D F
Manual tying F F E F
08/2002 9
Diagnosis QUADRANT 2200/ 2200 RC TIC
2.1 Service menu This menu serves as a tool in fault-finding. It shows the status of various
structure electrical components such as e.g. speed, voltage, pressure, switch
(from module 1 positions.
no. 835024.3)
To enter the service menu, press the keys “Scroll main menu”, “Plus
key” and “Minus key” at the same time.
The following mask appears:
Cutting Se r v i c e RC 8 2
frame angle W= 2 0 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A: 00000000 U: 11 , 6
F : 00000000 FFFF
10 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
2.2 Additional information about page "8/1 (Service 1)" (from module 1 no. 835024.3)
(P=) Current pressure The pressure in the baling chamber cylinders is displayed here in bars.
(L) Current bale length The length of the bale in the baling chamber is displayed here in metres
to the second decimal point.
(N0=) PTO shaft speed The calculated PTO shaft speed in revolutions per minute is displayed
here (this speed is measured by the drive speed sensor).
(N1=) Feed rake speed The feed rake speed in revolutions per minute is displayed here
(150 rpm at 1000 rpm PTO shaft speed)
(N2=) Rotor speed The rotor speed in revolutions per minute is displayed here (140 rpm at
1000 rpm PTO shaft speed)
(U:) Voltage The supply voltage is displayed here in Volt to the first decimal point.
Key test A combination of characters and numbers is displayed here to test the
function of the keys on the Control Terminal.
(P0) Control unit P+ The condition of the baling pressure build-up valve is displayed here.
The displayed number is proportional with the valve actuation and may
assume values from 0 to 255.
0 = Valve not actuated
255 = Valve fully actuated
(P1) Control unit P- The condition of the baling pressure relief valve is displayed here. The
displayed number is proportional with the valve actuation and may
assume values from 0 to 255.
0 = Valve not actuated
255 = Valve fully actuated
(E:) Inputs The condition of various circuits connected with the modules is
displayed here. Each numeric character corresponds to one circuit.
0 = Circuit open
1 = Circuit closed
(A:) Outputs The condition of various circuits connected with the modules is
displayed here. Each numeric character corresponds to one circuit.
0 = Circuit open
1 = Circuit closed
(F:) Error Malfunctions are displayed here. Each numeric character corresponds
to one error.
0 = No error
1 = Error
2.3 Additional information about page "8/2 (Service RC)" (up to module 1 no. 835024.3)
(W=) Cutting frame angle The cutting frame angle in degrees is displayed here. The higher the
value, the wider the cutting frame is open.
08/2002 11
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345678
Eight numeric characters are available for input diagnosis in line “E” on page "8 / 1 (Service 1)" and page
"8 / 2 (Service RC)", each of them being assigned to one circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
12 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e RC 8 2
W= 20 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A : 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
08/2002 13
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 00 N0 = 0
P0 0 N1 = 0
P1 0 N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
Eight numeric characters are available for output diagnosis in line “A” on page "8 / 1 (Service 1)" and page
"8 / 2 (Service RC)", each of them being assigned to one circuit.
It must be ensured that the baling pressure solenoid valves (P0 and P1) are not activated. To achieve this,
press the "Plus key" once.
The numeric characters only indicate if a solenoid valve is actuated by the corresponding module.
For diagnosis purposes, the corresponding function must be activated, i.e. the functions can be
checked only one by one.
The numeric characters may assume the following values:
0 = Solenoid valve is not actuated by the module
or
1 = Solenoid valve is actuated by the module.
Dependencies and switching sequences which may occur in normal operation have an influence.
14 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e RC 8 2
W= 20 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
08/2002 15
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 00 N0 = 0
P0 0 N1 = 0
P1 0 N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
To activate this function, keep the “Minus key” pressed while in the service menu, i.e. a maximum of
eight circuits may be checked at the same time.
Eight numeric characters are available for output diagnosis in line “A” on page "8 / 1 (Service 1)" and page
"8 / 2 (Service RC)", each of them being assigned to one circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed and/or solenoid coil OK.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
16 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e RC 8 2
W= 20 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
08/2002 17
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345678
Eight numeric characters are available for error display in line “F”, each of them being assigned to one error.
This function is available only on page 8/1 "Service 1".
The numeric characters may assume the following values:
0 = No error or
1 = Error.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
F3 Rotor overload Drive speed above 500 rpm and rotor speed
below 56 rpm
F4 Feed rake overload Drive speed above 500 rpm and feed rake
speed below 60 rpm
18 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345
Four numeric characters are available for key testing in line (1) shown above.
Pushing a key on the Control Terminal produces one of the combinations of numbers and characters shown
below which allow checking the function.
The character “G” at the 5th digit indicates if the central lubrication system is currently active, otherwise this
digit remains free.
Example: When the central lubrication system is active and the “Minus” key is pressed, the numeric
characters read “FDFFG”. If the central lubrication system is not active and the “Minus key” is
pressed, the numeric characters read “FDFF”.
ROTOCUT knives ON B F F F
Minus F D F F
Plus F F D F
Manual tying F F E F
08/2002 19
Diagnosis QUADRANT 2200/ 2200 RC TIC
To enter the service menu, press the keys “Scroll main menu”, “Plus
key” and “Minus key” at the same time.
The following mask appears:
Cutting Se r v i c e RC 8 2
frame angle W= 2 0 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A: 00000000 U: 11 , 6
F : 00000000 FFFF
20 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
3.2 Additional information about page "8/1 (Service 1)" (on CCU module)
(P=) Current pressure The pressure in the baling chamber cylinders is displayed here in bars.
(L) Current bale length The length of the bale in the baling chamber is displayed here in metres
to the second decimal point.
(N0=) PTO shaft speed The calculated PTO shaft speed in revolutions per minute is displayed
here (this speed is measured by the drive speed sensor).
(N1=) Feed rake speed The feed rake speed in revolutions per minute is displayed here
(150 rpm at 1000 rpm PTO shaft speed)
(N2=) Rotor speed The rotor speed in revolutions per minute is displayed here (140 rpm at
1000 rpm PTO shaft speed)
(U:) Voltage The supply voltage is displayed here in Volt to the first decimal point.
Key test A combination of characters and numbers is displayed here to test the
function of the keys on the Control Terminal.
(P0) Control unit P+ The condition of the baling pressure build-up valve is displayed here.
The displayed number is proportional with the valve actuation and may
assume values from 0 to 255.
0 = Valve not actuated
255 = Valve fully actuated
(P1) Control unit P- The condition of the baling pressure relief valve is displayed here. The
displayed number is proportional with the valve actuation and may
assume values from 0 to 255.
0 = Valve not actuated
255 = Valve fully actuated
(E:) Inputs The condition of various circuits connected with the modules is
displayed here. Each numeric character corresponds to one circuit.
0 = Circuit open
1 = Circuit closed
(A:) Outputs The condition of various circuits connected with the modules is
displayed here. Each numeric character corresponds to one circuit.
0 = Circuit open
1 = Circuit closed
(F:) Error Malfunctions are displayed here. Each numeric character corresponds
to one error.
0 = No error
1 = Error
3.3 Additional information about page "8/2 (Service RC)" (on CCU module)
(W=) Cutting frame angle The cutting frame angle in degrees is displayed here. The higher the
value, the wider the cutting frame is open.
08/2002 21
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345678
Eight numeric characters are available for input diagnosis in line “E” on page "8 / 1 (Service 1)", each of them
being assigned to one circuit.
The numeric characters may assume the following values:
0 = Circuit open or
1 = Circuit closed.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
22 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e RC 8 2
W= 20 N0 = 0
255 N1 = 0
N2 = 0
E : 00000000
A : 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
08/2002 23
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 00 N0 = 0
P0 0 N1 = 0
P1 0 N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
Eight numeric characters are available for output diagnosis in line “A” on page "8 / 1 (Service 1)" and page
"8 / 2 (Service RC)", each of them being assigned to one circuit.
It must be ensured that the baling pressure solenoid valves (P0 and P1) are not activated. To achieve this,
press the "Plus key" once.
The numeric characters only indicate if a solenoid valve is actuated by the corresponding module.
For diagnosis purposes, the corresponding function must be activated, i.e. the functions can be
checked only one by one.
The numeric characters may assume the following values:
0 = Solenoid valve is not actuated by the module or
1 = Solenoid valve is actuated by the module.
Dependencies and switching sequences which may occur in normal operation have an influence.
The table below applies to page "8 / 1 (Service 1)"
24 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e 1 8 1
P= 0L 0 , 00 N0 = 0
P0 0 N1 = 0
P1 0 N2 = 0
E : 00000000
A: 00000000 U : 11 , 6
F : 00000000 FFFF
12345678
08/2002 25
Diagnosis QUADRANT 2200/ 2200 RC TIC
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345678
Eight numeric characters are available for error display in line “F”, each of them being assigned to one error.
This function is available only on page 8/1 "Service 1".
The numeric characters may assume the following values:
0 = No error or
1 = Error.
All numeric characters show the respective state independently of each other. Dependencies and switching
sequences which may occur in normal operation have no influence.
F3 Rotor overload Drive speed above 500 rpm and rotor speed
below 56 rpm
F4 Feed rake overload Drive speed above 500 rpm and feed rake speed
below 60 rpm
26 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
Se r v i c e 1 8 1
P= 0L 0 , 0 0 N0 = 0
P0 255 N1 = 0
P1 0 N2 = 0
E : 0000000 0
A : 0000000 0 U : 11 , 6
F : 0000000 0 FFFF
12345
Four numeric characters are available for key testing in line (1) shown above.
Pushing a key on the Control Terminal produces one of the combinations of numbers and characters shown
below which allow checking the function.
The character “G” at the 5th digit indicates if the central lubrication system is currently active, otherwise this
digit remains free.
Example: When the central lubrication system is active and the “Minus” key is pressed, the numeric
characters read “FDFFG”. If the central lubrication system is not active and the “Minus key” is
pressed, the numeric characters read “FDFF”.
ROTOCUT knives ON B F F F
Minus F D F F
Plus F F D F
Manual tying F F E F
08/2002 27
Diagnosis QUADRANT 2200/ 2200 RC TIC
28 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
4.2 Testing the The service menu of the Control Terminal (see description in chapter 3.)
metering can be used to check the metering wheel sensor.
The pulses of the metering wheel sensor can be tested individually in the
wheel / bale service menu in the "Inputs" line. The numeric characters 7 and 8
length sensor change between “1” and “0” in a given pattern, which allows to identify
(B69) the sense of rotation of the metering wheel.
(with central To this end, slowly rotate the metering wheel and watch the display in
terminal the Control Terminal. The tables show an extract of the numeric
compartment) character sequence which is repeated while the metering wheel rotates.
Sensor Sensor
1SI10 1SI11 1SI10 1SI11
0 0 0 0
0 1 1 0
1 1 1 1
1 0 0 1
B)
A)
08/2002 29
Diagnosis QUADRANT 2200/ 2200 RC TIC
Ejecting bales The bale length determined by the metering wheel when ejecting bales
is saved in the baler module and added to the next bale later during
baling. This value is stored even after switching off the ignition.
The baling pressure is relieved when the bale is ejected.
Overload protection When the maximum allowed ram force is exceeded, the baling pressure
is abruptly relieved. This shuts down the baling pressure control for 7
seconds. After this, the pre-set baling pressure is built up again.
Knotter cleaning The knotter is cleaned directly prior to tying the bale and after half the
bale length has been reached.
Speed sensors At a PTO shaft speed of approx. 350 rpm, the speed sensors (drive,
feed rake, rotor) should display a correct value.
Bale length display When the bale length bar in the Control Terminal remains completely
dark and when bale tying is not possible (e.g. by excessively fast
rotation of the metering wheel by hand), the tying release must be reset.
To do this, proceed as follows:
1. With the CCT switched on, turn back metering wheel until bar
stops being dark
2. Wait for approx. 10 s
3. Switch CCT off / on.
Manual tying start To be able to carry out a manual tying start on balers from machine no.,
the metering wheel must have measured a bale length of at least
approx. 40 cm.
30 08/2002
TIC QUADRANT 2200/ 2200 RC Diagnosis
After replacing the module, the data from the CDS must be restored to
the machine.
Suitable programs are available in the diagnosis menu. This ensures
that machine-specific data will not be modified.
08/2002 31
Diagnosis QUADRANT 2200/ 2200 RC TIC
Notes
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
32 08/2002
Following the policy of CLAAS KGaA mbH to improve
their products as technical developments continue,
CLAAS reserve the right to make alterations which
must not necessarily correspond to text and
illustrations contained in this publication, and without
incurring obligation to alter any machines previously
delivered.
0299 251.2
SYS-D QUADRANT 2200/RC
EN - 05.05 - NF
Printed in Germany