You are on page 1of 38

Subdivision Load Line

S.T
0
0.5
1
1.5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18.5
19
19.5
20

Measured (mm)
0.9
2.0
2.5
3.1
4.0
6.0
7.2
8.2
9.4
10.1
11.0
10.5
10.0
10.0
10.0
9.0
8.2
7.0
5.5
4.5
2.5
2.1
2.0
1.0
1.0

Area (m2)
18.44
40.99
51.24
63.53
81.98
122.96
147.56
168.05
192.64
206.99
225.43
215.19
204.94
204.94
204.94
184.45
168.05
143.46
112.72
92.22
51.24
43.04
40.99
20.49
20.49

S.M
0.5
2
1
2
1.5
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
1.5
2
1
2
0.5

F(v)
9.22
81.98
51.24
127.06
122.96
491.86
295.11
672.20
385.29
827.96
450.87
860.75
409.88
819.76
409.88
737.78
336.10
573.83
225.43
368.89
76.85
86.07
40.99
40.99
10.25

F(v)=

8513.2076

Lever
-10
-9.5
-9
-8.5
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
8.5
9
9.5
10

F(Mv)
-92.22
-778.77
-461.12
-1080.03
-983.71
-3442.99
-1770.68
-3361.02
-1541.15
-2483.87
-901.74
-860.75
0.00
819.76
819.76
2213.35
1344.41
2869.16
1352.60
2582.24
614.82
731.64
368.89
389.39
102.47

F(Mv)=

-3549.5608

Load Displacement()=(h/3* F(v))


L.C.B (x)=(h*(F(Mv)/F(v))

25965.28
-3.82

Trim Line 1A
S.T
0
0.5
1
1.5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18.5
19
19.5
20

Measured (mm)
8.93
9.73
10.70
11.6339
12.4496
13.9686
15.3134
16.3405
17.0683
17.4467
17.5441
17.3787
16.9979
16.4112
15.6635
14.5889
13.2782
11.6583
9.7042
7.4906
5.1594
3.8770
2.9827
2.0047
1.0675

Area (m2)
182.9499
199.4538
219.2735
238.4251
255.1421
286.2725
313.8328
334.8822
349.7977
357.5527
359.5488
356.1591
348.3550
336.3311
321.0078
298.9849
272.1234
238.9252
198.8779
153.5124
105.7367
79.4552
61.1275
41.0843
21.8773

S.M
0.5
2
1
2
1.5
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
1.5
2
1
2
0.5

F(v)
91.47
398.91
219.27
476.85
382.71
1145.09
627.67
1339.53
699.60
1430.21
719.10
1424.64
696.71
1345.32
642.02
1195.94
544.25
955.70
397.76
614.05
158.61
158.91
61.13
82.17
10.94

F(v)= 15818.53675

2H/3
scaled
y cordinate
X cordinate

cad values
scale x 1 mm=.305 m , 1m =3.27688524
4.0422225
51.97143214
148.5999964
600

Lever
-10
-9.5
-9
-8.5
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
8.5
9
9.5
10

F(Mv)
-914.75
-3789.62
-1973.46
-4053.23
-3061.71
-8015.63
-3765.99
-6697.64
-2798.38
-4290.63
-1438.20
-1424.64
0.00
1345.32
1284.03
3587.82
2176.99
4778.50
2386.53
4298.35
1268.84
1350.74
550.15
780.60
109.39

F(Mv)=

-18306.61595

m , 1m =3.27688524

1)
2)
3)
4)
5)
6)

Displacement(2)=(h/3* F(v))
L.C.B (x2)=(h*(F(Mv)/F(v))
D.W Volume (V2)=(2-)
Shift of L.C.B=(X2-X)
C.G of D.W from L.C.B(X2)=((*Shift of L.C.B)/V2)
C.G of D.W from ( ) = (5+2)

scale y 1mm = .077777777m , 1m = 12.85714285714

0.435663406

48246.54
-10.59
22281.25
-6.77
-7.89
-18.48

scaled area ( y )
79.7045932
86.89470286
95.52944152
103.8731116
111.1560775
124.7184475
136.7254752
145.8959231
152.3940751
155.7726141
156.6422486
155.1654771
151.7655097
146.527167
139.8513381
130.2567872
118.5542208
104.0909666
86.6438124
66.87971612
46.0656299
34.61573965
26.63099475
17.89893559
9.531158647

Compartment Length Calculation for Trim Line 1A


Permeability =
L.C.G of D.W from , Xw =
Damage Volume V2 =
Compartment Volume Vc= ( V2/)
Mean Sec. Area =

0.60
-18.48
22281.25
37135.42
359.56

Iteration 1

1)
2)
3)
4)
5)
6)
7)
8)

Trial Floodable Length l = (Vc/Mean Sec. Area)


Trial Xm =
Corresponding Xc =
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
Approx flood. Length = (l*Vc/ (5))
Approx Xc = Xw + Xm

103.28
0.00
-18.48
25.82
34205.48
0.25
112.13
-18.23

Iteration 2

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (7 of previous iteration)


Trial Xc = (8 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

112.13
-18.23
28.03
36584.43
0.28
113.81
-18.20

Iteration 3

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (6 of previous iteration)


Trial Xc = (7 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

113.81
-18.20
28.45
37024.07
0.29
114.16
-18.19

cad

scale x cordinate

iteration 1
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

135.6593
87.6881
39.71688
183.6305
231.6018

1m=1.85792349

y cordinate

iteration 2
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

136.1309
84.05057
31.97026
188.2112
240.2915

x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

136.1858
83.32109
30.45641
189.0505
241.9151

iteration 3
xc

on for Trim Line 1A

Scale For Sec. Area curve =


Section
0
1
2
3
4

Measured
Section Area S.M
115.83
265.86
147.11
337.67
156.65
359.56
147.67
338.96
123.22
282.83
F(v) =

1
4
2
4
1

F(v)
Lever
265.86
-2
1350.69
-1
719.13
0
1355.82
1
282.83
2
3974.33 F(Mv) =

F(Mv)
-531.72
-1350.69
0.00
1355.82
565.66
39.07

0
1
2
3
4

Measured
Section Area S.M
109.47
251.28
145.45
333.86
156.64
359.54
146.11
335.37
116.78
268.06
F(v) =

1
4
2
4
1

F(v)
Lever
251.28
-2
1335.46
-1
719.08
0
1341.48
1
268.06
2
3915.36 F(Mv) =

F(Mv)
-502.56
-1335.46
0.00
1341.48
536.12
39.58

0
1
2
3
4

Measured
Section Area S.M
108.20
248.37
145.11
333.07
156.64
359.54
145.82
334.70
115.49
265.10
F(v) =

1
4
2
4
1

F(v)
Lever
248.37
-2
1332.28
-1
719.08
0
1338.79
1
265.10
2
3903.62 F(Mv) =

F(Mv)
-496.73
-1332.28
0.00
1338.79
530.20
39.98

Section

Section

1m2=

0.435663

2.29535

47.767

Trim Line 2A
S.T
0
0.5
1
1.5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18.5
19
19.5
20

Measured (mm)

cad values
2H/3
scaled
y cordinate

Area (m2)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

S.M
0.5
2
1
2
1.5
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
1.5
2
1
2
0.5

F(v)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F(v)=

scale x 1 mm=.305 m , 1m =3.27688524


8.084445
103.9428643
96.62856429

X cordinate

600

Lever
-10
-9.5
-9
-8.5
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
8.5
9
9.5
10

F(Mv)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F(Mv)=

1)
2)
3)
4)
5)
6)

Displacement(2)=(h/3* F(v))
L.C.B (x2)=(h*(F(Mv)/F(v))
D.W Volume (V2)=(2-)
Shift of L.C.B=(X2-X)
C.G of D.W from L.C.B(X2)=((*Shift of L.C.B)/V2)
C.G of D.W from ( ) = (5+2)

scale y 1mm = .077777777m , 1m = 12.85714285714

cad

0
#DIV/0!
-25965.28318
#DIV/0!
#DIV/0!
#DIV/0!

0.435663406

scaled x cordinate

scaled area ( y )
0

8.5

17

25.5

34

51

68

85

102

119

136

153

170

187

204

221

238

255

272

289

306

314.5

323

331.5

340

Compartment Length Calculation for Trim Line 2A


Permeability =
L.C.G of D.W from , Xw =
Damage Volume V2 =
Compartment Volume Vc= ( V2/)
Mean Sec. Area =

0.6
#DIV/0!
-25965.3
-43275.5

1)
2)
3)
4)
5)
6)
7)
8)

Trial Floodable Length l = (Vc/Mean Sec. Area)


Trial Xm =
Corresponding Xc =
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
Approx flood. Length = (l*Vc/ (5))
Approx Xc = Xw + Xm

#DIV/0!

Iteration 2

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (7 of previous iteration)


Trial Xc = (8 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Iteration 3

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (6 of previous iteration)


Trial Xc = (7 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Iteration 1

cad

scale x cordinate

iteration 1
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

1m=1.85792349

0
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

y cordinate 1m2=

iteration 2
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

iteration 3
xc

r Trim Line 2A

Scale For Sec. Area curve =


Section

Measured
0
1
2
3
4

Section

Measured
0
1
2
3
4

Section

Measured
0
1
2
3
4

0.435663

Section Area S.M


0
0
0
0
0
F(v) =

1
4
2
4
1

Section Area S.M


0
0
0
0
0
F(v) =

Section Area S.M


0.00
0.00
0.00
0.00
0.00
F(v) =

F(v)

Lever
0
-2
0
-1
0
0
0
1
0
2
0 F(Mv) =

F(Mv)

Lever
0
-2
0
-1
0
0
0
1
0
2
0 F(Mv) =

F(Mv)

1
4
2
4
1

1
4
2
4
1

F(v)
Lever
0.00
-2
0.00
-1
0.00
0
0.00
1
0.00
2
0.00 F(Mv) =

F(v)

0
0
0
0
0
0

0
0
0
0
0
0

F(Mv)
0.00
0.00
0.00
0.00
0.00
0.00

Trim Line 3A
S.T
0
0.5
1
1.5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18.5
19
19.5
20

Measured (mm)

Area (m2)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

S.M
0.5
2
1
2
1.5
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
1.5
2
1
2
0.5

F(v)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Lever
-10
-9.5
-9
-8.5
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
8.5
9
9.5
10

F(v)=

F(Mv)=

F(Mv)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1)
2)
3)
4)
5)
6)

Displacement(2)=(h/3* F(v))
L.C.B (x2)=(h*(F(Mv)/F(v))
D.W Volume (V2)=(2-)
Shift of L.C.B=(X2-X)
C.G of D.W from L.C.B(X2)=((*Shift of L.C.B)/V2)
C.G of D.W from ( ) = (5+2)

cad

0
#DIV/0!
-25965.28318
#DIV/0!
#DIV/0!
#DIV/0!

0.435663406

scaled x cordinate

scaled area ( y )
0

8.5

17

25.5

34

51

68

85

102

119

136

153

170

187

204

221

238

255

272

289

306

314.5

323

331.5

340

Compartment Length Calculation for Trim Line 3A


Permeability =
L.C.G of D.W from , Xw =
Damage Volume V2 =
Compartment Volume Vc= ( V2/)
Mean Sec. Area =

0.6
#DIV/0!
-25965.3
-43275.5

1)
2)
3)
4)
5)
6)
7)
8)

Trial Floodable Length l = (Vc/Mean Sec. Area)


Trial Xm =
Corresponding Xc =
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
Approx flood. Length = (l*Vc/ (5))
Approx Xc = Xw + Xm

#DIV/0!

Iteration 2

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (7 of previous iteration)


Trial Xc = (8 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Iteration 3

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (6 of previous iteration)


Trial Xc = (7 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Iteration 1

cad

scale x cordinate

iteration 1
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

1m=1.85792349

0
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

y cordinate 1m2=

iteration 2
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

iteration 3
xc

r Trim Line 3A

Scale For Sec. Area curve =


Section

Measured

Section Area

0
1
2
3
4

S.M
0
0
0
0
0

F(v)

Lever
0
-2
0
-1
0
0
0
1
0
2
0 F(Mv) =

F(Mv)

Lever
0
-2
0
-1
0
0
0
1
0
2
0 F(Mv) =

F(Mv)

1
4
2
4
1

1
4
2
4
1

F(v)
Lever
0.00
-2
0.00
-1
0.00
0
0.00
1
0.00
2
0.00 F(Mv) =

1
4
2
4
1
F(v) =

Section

Measured
0
1
2
3
4

Section Area

S.M
0
0
0
0
0

F(v)

F(v) =

Section

Measured
0
1
2
3
4

0.435663

Section Area
S.M
0.00
0.00
0.00
0.00
0.00
F(v) =

0
0
0
0
0
0

0
0
0
0
0
0

F(Mv)
0.00
0.00
0.00
0.00
0.00
0.00

Trim Line 1F
S.T
0
0.5
1
1.5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18.5
19
19.5
20

Measured (mm)

Area (m2)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

S.M
0.5
2
1
2
1.5
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
1.5
2
1
2
0.5

F(v)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

F(v)=

Lever
-10
-9.5
-9
-8.5
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
8.5
9
9.5
10

F(Mv)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

F(Mv)=

1)
2)
3)
4)
5)
6)

cad

Displacement(2)=(h/3* F(v))
L.C.B (x2)=(h*(F(Mv)/F(v))
D.W Volume (V2)=(2-)
Shift of L.C.B=(X2-X)
C.G of D.W from L.C.B(X2)=((*Shift of L.C.B)/V2)
C.G of D.W from ( ) = (5+2)

0.00
#DIV/0!
-25965.28
#DIV/0!
#DIV/0!
#DIV/0!

scaled x cordinate
0
8.5
17
25.5
34
51
68
85
102
119
136
153
170
187
204
221
238
255
272
289
306
314.5
323
331.5
340

0.435663406
scaled area ( y )
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Compartment Length Calculation for Trim Line 1F


Permeability =
L.C.G of D.W from , Xw =
Damage Volume V2 =
Compartment Volume Vc= ( V2/)
Mean Sec. Area =
Iteration 1

0.6
#DIV/0!
-25965.28
-43275.47197

1)
2)
3)
4)
5)
6)
7)
8)

Trial Floodable Length l = (Vc/Mean Sec. Area)


Trial Xm =
Corresponding Xc =
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
Approx flood. Length = (l*Vc/ (5))
Approx Xc = Xw + Xm

#DIV/0!

Iteration 2

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (7 of previous iteration)


Trial Xc = (8 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Iteration 3

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (6 of previous iteration)


Trial Xc = (7 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

cad

scale x cordinate

iteration 1
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

1m=1.85792349

0
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

y cordinate

1m2=

iteration 2
xc
x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

x cord,2=
x cord,1=
x cord,0=
x cord,3=
x cord,4=

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

iteration 3
xc

m Line 1F

Scale For Sec. Area curve =


Section

Measured

Section Area

0
1
2
3
4

S.M
0
0
0
0
0

F(v)

Lever
0
-2
0
-1
0
0
0
1
0
2
0 F(Mv) =

F(Mv)

Lever
0
-2
0
-1
0
0
0
1
0
2
0 F(Mv) =

F(Mv)

1
4
2
4
1

1
4
2
4
1

F(v)
Lever
0.00
-2
0.00
-1
0.00
0
0.00
1
0.00
2
0.00 F(Mv) =

1
4
2
4
1
F(v) =

Section

Measured

Section Area

0
1
2
3
4

S.M
0
0
0
0
0

F(v)

F(v) =

Section

Measured
0
1
2
3
4

Section Area

S.M
0.00
0.00
0.00
0.00
0.00
F(v) =

0.435663

0
0
0
0
0
0

0
0
0
0
0
0

F(Mv)
0.00
0.00
0.00
0.00
0.00
0.00

Trim Line 1F
S.T
0
0.5
1
1.5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18.5
19
19.5
20

Measured (mm)

Area (m2)

S.M

F(v)=

F(v)

Lever

F(Mv)

1)
2)
3)
4)
5)
6)

Displacement(2)=(h/3* F(v))
L.C.B (x2)=(h*(F(Mv)/F(v))
D.W Volume (V2)=(2-)
Shift of L.C.B=(X2-X)
C.G of D.W from L.C.B(X2)=((*Shift of L.C.B)/V2)
C.G of D.W from ( ) = (5+2)
Load Displacement()=(h/3* F(v))
L.C.B (x)=(h*(F(Mv)/F(v))

F(Mv)=

Permeability =
L.C.G of D.W from , Xw =
Damage Volume V2 =
Compartment Volume Vc= ( V2/)
Mean Sec. Area =
Iteration 1

1)
2)
3)
4)
5)
6)
7)
8)

Trial Floodable Length l = (Vc/Mean Sec. Area)


Trial Xm =
Corresponding Xc =
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
Approx flood. Length = (l*Vc/ (5))
Approx Xc = Xw + Xm

Iteration 2

1)
2)
3)
4)
5)
6)
7)

Trial Floodable Length l = (7 of previous iteration)


Trial Xc = (8 of Previous Iteration)
Station Spacing S = ( l/4 )
Computed Vol. = (s/3* F(v))
Computed Xm ( w.r.t Xc)=(s*(F(Mv)/F(v))
flood. Length = (l*Vc/ (5))
Xc = Xw + Xm

Scale For Sec. Area curve =


Section

Measured

Section Area

S.M

F(v)

Lever

0
1
2
3
4
F(v) =

Section

Measured

Section Area

S.M

F(Mv) =

F(v)

Lever

0
1
2
3
4
F(v) =

F(Mv) =

F(Mv)

F(Mv)

You might also like