You are on page 1of 2

Appd. Rev.

Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
K Ekstrm 2011-05-03
DM
Vignesh
1JNS10150D1ME 2
1
Foundation Plan
A
F10150
2011-06-29
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
N
2011-05-03 VENDOR'S DRG. NO.-
UNIT: PACKAGE :
SCALE -
TITLE :
DESIGN
DRAWN
CHKD
APPROVED
DATE
REV. SH.No.
PROJECT DRG.NO.-
CATEGORY OF DRG. APPROVAL INFORMATION REFERENCE RECORD CONSTRUCTION
SIZE A1
6MPTA INTEGRATED STEEL PLANT AT ANGUL, ORISSA
JINDAL STEEL & POWER LIMITED
-
1 of 1
0
C
0
9
1 0
O
I
S
MP
O
A
N
Y
MECON LIMITED
ASEA BROWN BOVERI
Vignesh
Vignesh
Katarina
Katarina
Foundation Plan
1:100
Y
Mx
My
Fx
Fy
X
TOLERANCES (mm)
Level between foundations 10
for top of concrete foundations
Surface on foundation
Minimum acceptable surface smoothness
3 in a length of 2,0 m
5 in a length of 2,0 m
Maximum acceptable slope
3 in a length of 2,0 m
5 in a length of 2,0 m
2500
2800 1700
3880
15700
4
5
0
0
2
1
8
0
D1
K1
of Wall bushing
D1
D1
Gate
F1
F1
F1
F1
F1
F1
K4 K4
K2
K2
K2
K2
K1 K1 K1 K1 K1
K6
C2
K3 K3 K3 K3
C1 C1 C1
F2 F2 F2
C1 C1 C1
M1 M1 M1
M2 M2 M2
F3 F3 F3
C1 C1 C1
M4 M3
M4 M3
K5
K5
K5
M4 M3
K6
K1
K6 K6
C2
Fence
M5
M5
M5
K6
K6
K6
K6 K6
D1
K3
D1 D1
D1
D1
D1
C
L
SVC Building
D1
14000
2
9
5
0
2600 2300
5
9
0
0
5
7
0
0
5
7
0
0
4
3
0
0
2700
5
7
0
0
5
7
0
0
4
3
0
0
3880
1
8
0
0
3880
2500
3
3
0
0
2500 2500
3880
4
0
0
0
3
4
0
0
3880
2
8
0
0
2500
3
3
0
0
1000
3880
6
0
0
0
2000
6000
2
7
5
0
6000 4400 6000 6000 6000
2000
5500 5500 6000
3
9
8
0
1500
8500
3500
1250
2
9
0
0
2500 2250
3
2
3
0
3
2
3
0
3
9
8
0
4
4
2
0
4
0
0
0
3500
4
0
0
0
2
1
8
0

3500
5
0
0
0
1000
7000
5
8
0
2250
3
8
0
0
10800
5
5
0
0
3
0
5
0
2
8
0
0
3500
1500 2000 2200
3
1
0
0
2
8
0
0
4500
1000
2000 2000
1000
2000
Reference drawings
>5000 10
Foundation data : 1JNS10150D1MF
Building Civil info : 1JNS10150D1MD
Conduits and trench : 1JNS10150D1MG
JSPL Angul SVC-Q, India
Distance <5000 5
Fence height min 2000 mm
Building indoor level 0,00
Top foundation level 0,00
Current transformer C1, C2
Disconnector/Earth switch D1
Designation Foundation for
F1,F2,F3 Reactor
K1,K2,K3,K4,K5, K6 Pillars
M1,M2,M3,M4,M5 Capacitor Banks
A Foundation K4,M1,C1 position changed KE 2011-08-07
C
B
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
D
A
Appd. Rev. Revision Date
Prepared by
ABB AB - FACTS
Document No.
No. of sh.
Sheet
Rev Ind
Title (English)
Title (own language) Date
Issued by Dept
Approved by
Drawn by Assembly dwg
Vignesh
K Ekstrm 2011-05-03
DM
Vignesh
1JNS10150D1ME 2
2
Foundation Plan
A
F10150
2011-06-29
Form
No
Design checked by
Sheet
Cont
Year W
eek
Dept
Rev Ind
Drawn by
10650
5300
30400 13600 8700
15000 4000 2000 5000 3400 2000
2
6
0
0
0
21700 5600 4000 2000 3000
4
2
0
0
2
0
0
0
2000 6200 11200 2000 13200 2000
7
0
0
0
70200
B
w
ill b
e
p
ro
s
e
cu
te
d
. A
B
B
A
B
u
s
e
d
fo
r a
n
y
u
n
a
u
th
o
riz
e
d
p
u
rp
o
s
e
. C
o
n
tra
v
e
n
tio
n
m
u
s
t n
o
t b
e
im
p
a
rte
d
to
a
th
ird
p
a
rty
n
o
r b
e
w
ritte
n
p
e
rm
is
s
io
n
, a
n
d
th
e
co
n
te
n
ts
th
e
re
o
f
T
h
is
d
o
cu
m
e
n
t m
u
s
t n
o
t b
e
co
p
ie
d
w
ith
o
u
t o
u
r
12 11 10 9 8 7 6 5 4 3 2
1
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12
H
G
F
E
D
C
A
JSPL Angul SVC-Q, India
D1 D1
CL of Wall bushing
F1 F1
K4
K2
K4
K2
K2
K2
K1 K1 K1
F1 F1
F1 F1
K1 K1 K1 K1
C1 C1 C1
F2 F2 F2
C1 C1 C1
M1 M1 M1
M2 M2 M2
F3 F3 F3
C1 C1 C1
M4 M3
M3 M4
K5
K5
K5
K6 K6 K6 K6
M4 M3
C2 C2
K3 K3 K3
M5
M5
M5
K6
K6
K6
K6 K6
D1
K3 K3
D1 D1 D1 D1 D1 D1
SVC Building
D1

You might also like