Professional Documents
Culture Documents
General EvaluationWireline
Purpose
This chart is used to determine the decibel attenuation of casing
from the measured cement bond log (CBL) amplitude and convert
it to the compressive strength of bonded cement (either standard
or foamed).
Description
The amplitude of the first casing arrival is recorded by an acoustic
signal-measuring device such as a sonic or cement bond tool. This
amplitude value is a measure of decibel attenuation that can be
translated into a bond index (an indication of the percent of casing
cement bonding) and the compressive strength (psi) of the cement
at the time of logging.
Enter the chart on the y-axis with the log value of CBL amplitude
and move upward parallel to the 45 lines to intersect the appropriate casing size. At that point, move horizontally right to the attenuation scale on the right-hand y-axis. From this point, draw a line
through the appropriate casing thickness value to intersect the compressive strength scale. The casing wall thickness is calculated by
subtracting the nominal inside diameter (ID) from the outside
diameter (OD) listed on the table for threaded nonupset casing
and dividing the difference by 2.
Cem
258
Example
Given:
Log amplitude reading = 3.5 mV in zone of interest
and 1.0 mV in a well-bonded section (usually the lowest
millivolt value on the log), casing size = 7 in. at
29 lbm/ft, casing thickness = 0.41 in., and neat cement
(not foamed).
Find:
Compressive strength and bond index of the cement at
the time of logging.
Answer: Enter the 3.5-mV reading on the left y-axis of Chart
Cem-1 and proceed to the 7-in. casing line.
Move horizontally to intersect the right-hand y-axis at
8.9 dB/ft.
Determine the casing thickness as (7 6.184)/2 = 0.816/2
= 0.41 in. Draw a line from 8.9 dB/ft through the 0.41-in.
casing thickness point to the compressive strength scale.
Cement compressive strength = 2,100 psi.
To find the bond index, determine the decibel attenuation of the
lowest recorded log value by entering 1.0 mV on the left-hand y-axis
and proceeding to the 7-in. casing line. Move horizontally to intersect
the right-hand y-axis at 12.3 dB/ft.
Divide the precisely determined decibel attenuation for the CBL
amplitude in the zone of interest by this value for the lowest millivolt
value: 8.9/12.3 = 72% bond index.
A 72% bond index means that 72% of the casing is bonded. This
is not a well-bonded zone because a value of 80% bonding over a 10-ft
interval is historically considered well bonded. Although the logging
scale is a linear millivolts scale, the decibel attenuation scale is logarithmic. The millivolts log scale for the CBL value cannot rescaled
in percent of bonding. If it were, the apparent percent bonding
would be 65% because most bond log scales are from 0 to 100 mV
reading from left to right, over 10 divisions of track 1, or conversely
100% to 0% cement bonding for 0 mV = 100% bonding and
100 mV = 0% bonding.
Cement EvaluationWireline
Weight
per ft
(lbm)
Nominal
ID
(in.)
Drift
Diameter
(in.)
OD
(in.)
Weight
per ft
(lbm)
Nominal
ID
(in.)
Drift
Diameter
(in.)
OD
(in.)
11.60
3.428
3.303
412
9.50
11.60
13.50
4.090
4.000
3.920
3.965
3.875
3.795
434
16.00
4.082
3.957
11.50
13.00
15.00
17.70
18.00
21.00
4.560
4.494
4.408
4.300
4.276
4.154
4.435
4.369
4.283
4.175
4.151
4.029
17.00
20.00
22.00
23.00
24.00
26.00
28.00
29.00
30.00
32.00
35.00
38.00
40.00
6.538
6.456
6.398
6.366
6.336
6.276
6.214
6.184
6.154
6.094
6.004
5.920
5.836
6.413
6.331
6.273
6.241
6.211
6.151
6.089
6.059
6.029
5.969
5.879
5.795
5.711
13.00
14.00
15.00
15.50
17.00
20.00
23.00
5.044
5.012
4.974
4.950
4.892
4.778
4.670
4.919
4.887
4.849
4.825
4.767
4.653
4.545
20.00
24.00
26.40
29.70
33.70
39.00
7.125
7.025
6.969
6.875
6.765
6.625
7.000
6.900
6.844
6.750
6.640
6.500
14.00
17.00
19.50
22.50
5.290
5.190
5.090
4.990
5.165
5.065
4.965
4.865
15.00
16.00
18.00
20.00
23.00
5.524
5.500
5.424
5.352
5.240
5.399
5.375
5.299
5.227
5.115
24.00
28.00
32.00
36.00
38.00
40.00
43.00
44.00
49.00
8.097
8.017
7.921
7.825
7.775
7.725
7.651
7.625
7.511
7.972
7.892
7.796
7.700
7.650
7.600
7.526
7.500
7.386
17.00
20.00
22.00
24.00
26.00
26.80
28.00
29.00
32.00
6.135
6.049
5.989
5.921
5.855
5.837
5.791
5.761
5.675
6.010
5.924
5.864
5.796
5.730
5.712
5.666
5.636
5.550
34.00
38.00
40.00
45.00
55.00
8.290
8.196
8.150
8.032
7.812
8.165
8.071
8.025
7.907
7.687
29.30
32.30
36.00
40.00
43.50
47.00
53.50
9.063
9.001
8.921
8.835
8.755
8.681
8.535
8.907
8.845
8.765
8.679
8.599
8.525
8.379
512
534
758
858
9
658
958
Weight
per ft
(lbm)
Nominal
ID
(in.)
Drift
Diameter
(in.)
10
33.00
9.384
9.228
1034
32.75
40.00
40.50
45.00
45.50
48.00
51.00
54.00
55.50
10.192
10.054
10.050
9.960
9.950
9.902
9.850
9.784
9.760
10.036
9.898
9.894
9.804
9.794
9.746
9.694
9.628
9.604
1134
38.00
42.00
47.00
54.00
60.00
11.150
11.084
11.000
10.880
10.772
10.994
10.928
10.844
10.724
10.616
12
40.00
11.384
11.228
13
40.00
12.438
12.282
1338
48.00
12.715
12.559
16
55.00
15.375
15.187
1858
78.00
17.855
17.667
20
90.00
19.190
19.002
2112
92.50
103.00
114.00
20.710
20.610
20.510
20.522
20.422
20.322
2412
100.50
113.00
23.750
23.650
23.562
23.462
Weight per foot in pounds is given for plain pipe (no threads
or coupling).
Drift diameter is the guaranteed minimum inside diameter of
any part of the casing. Use drift diameter to determine the
largest-diameter equipment that can be safely run inside the
casing. Use inside diameter for volume capacity calculations.
Cem
General EvaluationWireline
Cement
Cem-1
InterpretationCased Hole
(former M-1)
194
140
176
115
273
340
Attenuation
(dB/m)
1
70
Compressive strength
(psi)
(mPa)
2
50
40
30
12
30
4,000
20
15
6 20
10
9
8
7
6
25
3,000
20
Casing thickness
(mm)
(in.)
0.6
15
24
0.5
28
10
0.4
10
32
15
2,000
9 lbm
7 in. at 2
4
CBL amplitude
(mV)
16
10
8
0.3
7
1,000
1,000
11 36
6
12
800
40
5
0.2
13
44
1
14
15
16
500
3
4
48
0.5
500
250
Foamed cement
3
52
1
100
17 56
0.5
300
2
13 3/8
3
10 /4
7
51/2
Cem
50
18
0.2
41/2
(dB/ft)
75/8
260
0.3
200
100
Standard
cement