Information before programming

===========================================================
<< Default Programmer Code (saved in PC) >>
Installer level
: INSTALLER
Administrator level
: ADMIN
User level
: USER
<< Default Password (saved in PBX) >>
Installer level
: 1234
Administrator level : 1234
User level
: 1234
The administrator level password is used for PBX Web Manager also.
Changing password from default is strongly recommended to prevent unexpected acc
ess.
<< Multi-site PBX Manager >>
The multi-site PBX manager can modify system data of master PBX and copy to anot
her PBX in private network easily for basic features such as system speed dial.
Demonstration mode is available without PBX.
Registration key is required to use multi-site PBX manager.
<< PBX Replacement >>
//KX-TDA100-200 MPR version 5.0 -> KX-TDA600 MPR version 5.0//
System data of KX-TDA100-200 MPR version 5.0 can be converted to system data of
KX-TDA600 MPR version 5.0.
Card configuration of KX-TDA600 should be same as KX-TDA100-200.
SLC16 is converted to ESLC16 automatically.
MSLC16 is converted to EMSLC16 automatically.
LCOT16 is converted to ELCOT16 automatically.
Other card should be same.
If ECHO16 card is installed on OPB3 card in KX-TDA100-200, the card has to be re
moved and the card data has to be deleted before system data convert.
If card is installed in slot 11 of KX-TDA100-200, the card has to be removed bef
ore system data convert.
Cards have to be installed to cabinet 2-4 of KX-TDA600 after system data convert
.
//KX-TDA100-200 MPR version 5.0 -> KX-TDA100D MPR version 1.0//
System data of KX-TDA100-200 MPR version 5.0 can be converted to system data of
KX-TDA100D MPR version 1.0.
Card configuration of KX-TDA100D should be same as KX-TDA100-200.
SLC16/CSLC16/MSLC16 are converted to MCSLC16 automatically.
Other card should be same.
If DHLC8 or SLC8 card is installed in KX-TDA100-200, the card has to be removed
before system data convert.
If card is installed in slot 8-11 of KX-TDA100-200, the card has to be removed b
efore system data convert.
<< TDE MPR version 2 and TDA MPR version 5 >>
// Card Software //
Software for DHLC / DLC should be version 5.002 or later, when VM connected with
the card has 5 - 8 digits mailbox.
Software for CSLC16 should be version 2.0000 or later for KX-TDA600. If other ve
rsion is used, noise may happen on other cards such as PRI.
Software for IPEXT16 should be version 2.001 or later (both pipext and pvoipext)
, when IP-PT NT3xx is connected with IPEXT16.
Software for OPB3 should be version 5.004 or later to use ESVM card.
<< TDA100D MPR version 5.1 >>
// Card Software //

Software for
s connected.
Software for
TDA0142CE:
TDA0155CE:
TDA0156CE:
TDA0158CE:

DLC should be version 7.000 or later, when DSS console or TVM/TVA i


DECT CS
version
version
version
version

should be upgraded for KX-WT series DECT handset.


7.000 or later
7.000 or later
7.000 or later
7.000 or later

If you are using CA or an NT400, we recommend that you change the following sett
ing to "250 s".2-3 System - Timers & Counters - Extension First Digit
===========================================================
===========================================================