Professional Documents
Culture Documents
Leadership in Circuit
Protection
The most diverse solutions to mitigate arc ash energy to keep people and equipment safe
'
The smallest and most cost effective way to meet selective coordination requirements
'
The most experienced, time-tested solutions to meet national & local code requirements
'
The easiest specications with the most tested fuse/circuit breaker and circuit breaker/circuit breaker
series rated combinations
'
The only one-stop shop to solve your design challenges using our expertise and an unmatched portfolio
Company
Customer Service
Quality
Driving Continuous Improvement
From design conception to the end product
quality is paramount to the performance and
reliability of Bussmann products. Rigorous
testing helps to ensure global standards are
met for the highest levels of quality
throughout the entire product range.
Innovation
Leveraging Technology to Drive
Customer Value
Bussmann recognises the need to
continually innovate and develop new
technology to meet the changing needs of
the market.
Utilising nearly 100 years of circuit protection
experience, Bussmann produces technical
products that deliver technical solutions to
todays demanding circuit protection needs.
Low Voltage
Standard:
Rated Voltage:
Rated Current:
Breaking Capacity:
Operating Class:
Sizes:
Fuse Bases:
Applications:
Other:
IEC 60269
400, 500 and 690Vac
0.5 to 125A
20 to 120kA
gG and aM
8x31, 10x38, 14x51 and 22x58mm
Full range of fuse holders available (CH Series)
Industrial and commercial
Low Voltage
BS88 Part 5
415Vac
20 to 800A
80kA
gG
76, 82 and 92mm centres
Designed to be used with wedge type fuse carriers
Utilities
Available in cylindrical slotted or non slotted tag versions
Medium Voltage
Standard:
Rated Voltage:
Rated Current:
Breaking Capacity:
Operating Class:
Applications:
Other:
Medium Voltage
Applications:
BS 2692-1
3.6 to 72.5kV
3.15 to 160A
Up to 40kA
Back-up
Suitable for primary side transformer protection, fuse switch combination, unit
fuse bases and fuse switches
ANSI
15 to 72kV
1 to 100A
20 to 63kA
Back-up
Suitable for primary side transformer protection, fuse switch combination, unit
fuse bases and fuse switches
IEEE C37-63
Up to 33kV lines
16 to 320A
Resettable
Suitable for spur line isolation in place of existing expulsion fuse links
High Speed
UL/CSA
700Vac. DC ratings available
1 to 100A
20kA
aR
From to 6x32 to 25x146mm
E-mail bulehighspeedtechnical@cooperindustries.com for details
Used for the protection of DC common bus, DC drives, power converters/
rectifiers and reduced voltage starters
UL/CSA
Up to 600Vac
1 to 6000A
200kA
Fast acting
Refer to relevant data sheets, available upon request
www.cooperbussmann.com/datasheetiec
E-mail bulehighspeedtechnical@cooperindustries.com for details
Suitable for medium power applications for UL markets
IEC 60947-3, 61643-11, 60269-2 and 60269-7, UL Listed and CCC accredited
1000 and 1500Vdc
1 to 630A
Up to 50kA
gPV
10x38, 14x51, 14x65, NH Style and XL Style
CHPV series for 10x38 fuse links, SD-D-PV for NH style, SD-XL-S for XL style
Solar applications
Standard:
IEC 61643-1, IEC 60364-7-12 and UL 1449 3rd edition
Rated Voltage:
600, 1000 and 1200Vdc
Earth Configuration: DC with and without lightning protection grid
Poles:
2 and 3
Applications:
Photovoltaic system protection
Other:
easyIDTM Local status indication standard, remote contact signaling optional
Universal 4-Pole
Standard:
Connectors:
Rated Voltage:
MCOV DC:
Grounding:
Applications:
Other:
UL Listed 497B
Screws
0-180V
6-180V
DIN-Rail
Measurement, control and regulation, and twisted pairs
Complement IEC, Wind and UL Type 2 and 3 DIN-Rail mount SPDs
RJ45/Ethernet
Standard:
Connectors:
Rated Voltage:
MCOV DC:
Grounding:
Applications:
Other:
UL Listed 497B
RJ45
48V
48V
DIN-Rail
RJ45 Connector Ethernet cables
Complement IEC, Wind and UL Type 2 and 3 DIN-Rail mount SPDs
UL Listed 497B
BNC
5V
6.4-8V
DIN-Rail
BNC Connector coaxial cables and video
Complement IEC, Wind and UL Type 2 and 3 DIN-Rail mount SPDs
Combiner Box
Combiner Box
Standard:
Rated Voltage:
Rated Current:
Number of Strings:
Operating Class:
IP Rating:
Enclosure Types:
Overcurrent Protection
Positive and negative, positive only, negative only
Configurations:
Terminal Blocks
Terminal Blocks
Standard:
Rated Voltage:
Rated Current:
Wire sizes:
SCCR:
Rated Impulse
Withstand Voltage
Types:
Colours:
Grey, blue, black, red, yellow, green, orange and yellow/green (grounding
blocks)
Accessories:
Side insertion bridges, top insertion bridges, top screw-on bridges, multi-pole
options, labels
DIN-Rail Types:
Applications:
Contactors
Enbray Contactors
10
Standard:
Rated Voltage:
Rated Current:
Operating Class:
Poles:
Applications:
Other:
IEC 60947-4-1
230 to 600Vac/500Vdc. Can be configured for higher voltage
10 to 1250A. Can be configured for higher current
Up to AC23. Normally open or normally closed options available
1 to 18 poles
High Power Switching for onerous circuit conditions and Traction
Wide range of accessories and control circuit voltages. Customs solutions also
available
Customer Care
Phone:
Fax:
Email:
bulesales@eaton.com
C3 Customer Center
The C3 portal supports the following Divisions: B-Line, Bussmann, Crouse-Hinds, Cooper Lighting, Cooper Power
Systems, Cooper Safety, and Cooper Wiring Devices.
Get started today at www.cooperc3.com by clicking Request User ID and Password.
Easy to Navigate
Simple to Use
Real-Time Data
Online Resources
Visit www.bussmann.com for the following resources:
Product profiles
Online catalogues for the latest United States and European catalogues
Application Engineering
Application Engineering assistance is available to all customers. The Application Engineering team is staffed by
university-qualified electrical engineers who are available with technical and application support.
Europe calls can be made between:
Monday - Thursday
8.30 a.m. - 4.30 p.m. GMT
Friday
8.30 a.m. - 4.00 p.m. GMT
Application Engineering can be reached via:
Phone:
Fax:
Email:
buletechnical@eaton.com
11
Eaton
Bussmann Business
Melton Road
Burton-on-the-Wolds
LE12 5TH
Leicestershire
United Kingdom
2013 Eaton Industries
Subject to technical modifications.
No responsibility is taken for misprints or errata.
Printed in the United Kingdom (09/13)
Reorder: PRODUCTGUIDE0913