Preface
Welcome to use MSG5200 equipment.
If you have used 5200-V3.1 and previous versions, you have had a full knowledge of our
equipment and it may be an easy thing for you to configure this equipment.
this guide carefully. If you have never used 5200 equipment, this guide provides you a quick
understanding of the equipment.
V 3.1
Made by liuxin 10125036
Mail:liu.xin71@zte.com.cn
Contact:03145111470
contents
Preface ...................................................................................................................................................... 1
commission guide ..................................................................................................................................... 3
1.
2.
3.
2.1.
2.2.
Hardware connection................................................................................................... 5
3.2.
3.3.
3.4.
3.5.
3.6.
3.7.
3.8.
3.9.
3.10.
3.11.
3.12.
3.13.
3.14.
3.15.
3.16.
3.17.
3.18.
3.19.
3.20.
commission guide
1. OverView of MSAG5200
MSAG is the access equipment of SS (soft switch equipment MGC). MSAG connects with
SS via H248 protocol (or MGCP). MSAG is made up of control cardmedia resources sub
card test card and several subscriber cards, converging with a certain amount of
narrowband analog phone access and broadband ADSL access. The phone services are
provided by SS and broadband services are provided by internet.
2. Hardware introduce
Type
Using Shelf/slot---function
GISB
GISE/GISB
with
VOIP subcard
VOIP ,GISB
card
card
accessory
ODTI
HDB
High-speed digital
subscriber card
STD
HDB
card accessory
ALC
RALC
TSLCE
GELC
GVDL
DLCE
card
GEI
SUPI
Backplane of the
ON(0010)
2) Hw connection:
Master shelf ----Uplink card: GEI
3) Fiber connection:
Fiber need connect with Swith/TXN;
check GISB BACT light change to green Flashing every half second The broadband
service is normal.
Also can using command to check uplink status
4) Subscriber cable connection:
Leave the first pin empty plug 3*8 cable connector then after that connector leave one
another pin plug another 3*8 cable connector, this for 1~16 user
Leave the last pin empty plug 3*8 cable connector then befor that connector leave
one another pin plug another 3*8 cable connector,this for 17~32 user
DSL service checking : GELC card ACT light change to green means DSL link up
VOIP service checking: ALC/RALC card hook light change to green means phone hook
up
Also can using command to check status
Console cable
Cross cable
Cross cable
Laptop
Laptop
Console cable
Network cable
Cross cable
Laptop
1) Power on the master shelf of the cabinet, and the two GISB are in positions. Make the
GISB in Slot 9 as the active card. All the data configurations below are based on the
situation where the Slot 9 is active. we recommend you set Slot 9 as active.
2) Enter the user name and password in serial port ;serial configure baud rate is 9600
Configure your laptop ip using 144.1.1.0/24 then telnet 144.1.1.1
user name/passwordzte/zte
See as below
Function
Transfer
SHELL
Debugging output
exit
ZXAN #
configure terminal
used.
ZXAN (config)#
ZXAN (config-msag)#
Hardware and
broadband data
configuration interface
Interface
interface
ZXAN (version)#
ZXAN (config-if)#
Step
Function
Go to cfg folder
r
1
/cfg
2
ZXAN #dir
ZXAN#del startrun.dat
ZXAN #cd /
ZXAN # cd data
Go to data folder
/data
Go to V0100 folder
/data/v0100
ZXAN #cd /
Go to data folder
/data
10
Go to V0101 folder
/data/v0101
11
12
Reboot system
Notes: all data running on flash, after reboot will reload save data; never do wr after you delete data
Step
Function
Add Rack
CTL_SHELF
3
SLAVE_SHELF connectid 1
SLAVE_SHELF connectid 2
(1-4)
GISE/GISB
Add slave shelf user board for each
service card
(ALC/RALC/DLCE/ODTI/HDB/G
ELC/GVDL)
ZXAN(config)#show subcard
10
ZXAN#write
Save data
Notes: Only after config rack system can start update version;uplink card GEI will be auto add by MSAG
Ip add:144.1.1.100
Submask:255.255.255.0
Ethernet cable
Number
Step
Function
ZXAN#config terminal
ZXAN(config)#interface mng1
ZXAN(config-if)#boot-server 144.1.1.100
ZXAN(config-if)#boot-username target
ZXAN(config-if)#boot-password target
FTP software
modify ftp server ip address;
modify ftp server username;
modify ftp server password;
ZXAN(config-if)#ex
ZXAN(config)#ex
ZXAN#wri
Run this ftp server software,you can see this windows as below:
Click
Step
Function
ZXAN#version
ZXAN(version)#download version
ics.bt
ZXAN(version)#download version
ics.fw
ZXAN(version)#download version
ics.mvr
ZXAN(version)#download version
voip_normal.fw
ZXAN(version)#download version
gise.bt
ZXAN(version)#download version
gise.mvr
ZXAN(version)#download version
gelca.bt
ZXAN(version)#download version
gelca.mvr
ZXAN(version)#download version
gdl.bt
ZXAN(version)#download version
gvdld.fw
ZXAN(version)#download version
gvdld.mvr
ZXAN(version)#download version
dti.bt
ZXAN(version)#download version
dti.mvr
ZXAN(version)#download version
dlce.mvr
Download dlce/tslceversion
ZXAN(version)#download version
tslce.mvr
as its boot
version
NotesALC/HDB no need version
update boot one-by-one slot for sevice card(except control card)
Number
Step
Function
ZXAN#version
Same for all the service cards for all the shelves
Step
Function
ZXAN#version
Step
Function
ZXAN#version
Step
Function
ZXAN#version
ZXAN(version)#main-backup version
Synchronization shelfno 1
synchronization shelfno 1
ZXAN(version)#main-backup version
Synchronization shelfno 2
synchronization shelfno 2
ZXAN(version)#main-backup version
Synchronization shelfno 3
synchronization shelfno 3
ZXAN(version)#show sync-status shelfno 3
Step
Function
ZXAN(version)#exit
ZXAN#show card
Step
Function
ZXAN#reboot shelfno 4
shelf 4
ZXAN#reboot shelfno 3
shelf 3
ZXAN#reboot shelfno 2
shelf 2
ZXAN#reboot shelfno 1
ZXAN#show card
Bras
Soft Bras
Connect the laptop on
Spare FE Uplink port
TRX Equipment
Subscriber cable
Numbe
Step
Function
ZXAN(config)#vlan database
ZXAN(vlan)#vlan 101,201,301,3999,401
together)
range
101 pvc 1
modem;
Enable the first PVC
upload speed
ZXAN(config)#interface gei_1/9/3
ZXAN(config-if)#switchport
101,201,301,3999,401 tag
ZXAN(config-if)#no shutdown
10
11
ZXAN#show runing
12
ZXAN#write
Notes: all data configure need check again,show running will be more easy to check all the configuration
If configure 1+1 uplink using sgsmartgroup
Authentication
software BRAS
failure testing methodsetting.doc
at MSAN.doc
Fiber
cable
Uplink network
subscribercable
modem
LAN
cable
Audio/video
cable
STB
television
1 Add user port PVC 2 untag to VOD vlan;Add uplink port tag to VOD Vlan
2 Change PVC 2 value same to modem;enable PVC 2
3 Add uplink port tag to MVlan
4 Change ADSL profile
IGMP configuration
Number
Step
Function
Create MVLan
239.194.0.170
5
adsl_1/5/1-32 pvc 2
7
ZXAN(config)#interface gei_1/9/3
ZXAN(config-if)#switchport vlan
vlan also
Port enable
10
11
12
VOD part
PVC2 enable
13
14
pvc 2
Notes: all data configure need check again,show running will be more easy to check all the configuration
IPTV
UNICAST AND
troubleshooting.doc
MULTICAST TESTING.doc
TRX Equipment
Subscriber cable
equipment preparing
1) Phone
2) Number of Network cables
3) Number of subscriber cables
Data preparing:
1) SS type & IP address
2) VOIP protocol H248 or MGCPprotocol port 2944 for h248
3) TID for narrow band user and RTP resource
4) MSAG VOIP IP address and next hop;NAT protocol
5) VOIP vlan
3)
VOIP subcard should be ok,first time configure will be take long time 10~15 minuter
2)
3)
4)
5)
Set MSAG voip ipaddress and set MSAG voip next hop
6)
7)
8)
9)
ZTE: USER
Step
Function
ZXAN(config)#show subcard
ZXAN(config)#vlan 301
ZXAN(config-vlan)#voip-bind
ZXAN(config-vlan)#voip-ctrl
ZXAN(config-vlan)#exit
ZXAN#msag
Config softswitch(MGC)
type 1
parameter
Softswitch(MGC)
5
ZXAN(config-msag)#media-nat add 9 1 9 5 5
10.63.86.113 10000
Nat
USER0000~USER00XX..ETC
mgid 1
A0~Axxx
start RTP000~RTP0XX
begin-seqno 1 240
RTP/0~RTP/xx
ZXAN(config)#interface gei_1/9/3
ZXAN(config-if)#switchport vlan
301
tag
255.255.255.0
ZXAN(config-if)#exit
ZXAN(config)# ip route 10.0.0.0 255.0.0.0
10.63.86.254 (vrrp ip , voip next hope )
Add
route to PING SS ,
Now Ping SS ip
ZXAN#show msag mg
check RTP
check TID
Notes: all data configure need check again,show running will be more easy to check all the configuration
Uplink network
Fiber cable
LAN cable-outband
Serial cable-console port
terminal
Step
Function
ZXAN(config)#interface gei_1/9/4
ZXAN(config-if)#exit
Create L3 ip address
255.255.255.0
6
ZXAN(config-if)#exit
10.100.10.1
network
ZXAN#ping 10.100.10.1
Ping
ZXAN#ping 10.100.10.1
sending 5,100-byte ICMP echos to 10.100.10.1,timeout is 2 seconds.
!!!!!
Success rate is 100 percent(5/5),round-trip min/avg/max= 0/8/40 ms.
3) Simple trouble shooting
1) Using spare FE uplink to connect one laptop ,configure this spare port in NMS vlan
Configure Laptop ipaddress same to NMS next hop IP
2) Ping MSAG using laptop
NMS.doc
GE uplink
Number
Step
Function
ZXAN(config)#interface smartgroup1
create smartgroup 1
ZXAN(config-if)exit
ZXAN(config)#interface fei_1/9/3
ZXAN(config)#interface fei_1/9/4
Activepassiveon
Smartgroup:1
Flag *--LOOP is TRUE
Actor
Agg
Port
State
LACPDUs
Port
Oper
Port
RX
Mux
State Machine
Machine
----------------------------------------------------------------------------gei_1/9/3
selected
30
32768
0x103
0x3d
current
distributing
gei_1/9/4
selected
30
32768
0x103
0x3d
current
distributing
if you see two port are all select, means the one plus one function is OK, you can do the
test!
3.10.
Uplink network
gei_1/11
gei_1/11
VRRP ipaddress:10.10.10.3/24
gei_1/10
gei_1/10
VLAN 300 interface
gei_2/22
ipaddress:10.10.10.1/24
gei_2/22
gei_1/9/3
gei_1/9/4
AG
VLAN plan:
100 HSI
200 NMS
300 VOIP
IP plan:
NMS 12.12.12.254/24 nexthop 12.12.12.1/24
VOIP 10.10.10.254/24 nexthop 10.10.10.3/24
modem
Number
Step
Function
ZXAN#configure termianal
ZXAN(config)#uaps-group 1
2
ZXAN(cfg-uaps-1)#port
master-port
gei_1/9/4
slave-port gei_1/9/3
active,
1/9/3
for
standby)
ZXAN(cfg-uaps-1)#next-hop
10.10.10.3
media
link-type
3.11.
Revertive control
: disable
Next-hop
: 10.10.10.3
Link-type
: media
Link-detect-retry
: 5
Link-detect-interval
: 3
Link status
: connected or NA
Bfd next_hop
: 0.0.0.0
Bfd
: connected or NA
Link status
Switch-type
: common port
: block
: forwarding gei_1/9/4 : up
gei_1/9/3 : up
Selfswitch function
Step
Function
Get result
888XX servicetype 1
3.12.
EPM configuration
Creat SNMP TRAP SERVER first use the following command set to set SNMP TRAP
SERVER
Zxan(config)#snmp-server host 116.71.241.228 trap
version
2c
public
enable
NOTIFICATIONS
2c
public
enable
NOTIFICATIONS
2c
private
enable
trap
NOTIFICATIONS
ZXAN(config)#fan-epm-console epm
Show fan-epm-console
1. Create EPM unit on nms
5,only need config the sensor 1 , after this , you can test if all the sensor works well
7,click
create button
8. COM No usually be 2 , the power type depend on which type of power the site use, then
create OK
9,then at here you will see the temperature , humidity , AC, DC, battery sensor value
11,for test the temperature sensor , you can config the upper value very low
10. power threshold config , config 52 for battery and DC voltage test
3.13.
choose viice
coding,
If you still find issue in dialing phone numbers like 1218, 080080800 , 1217, 131 777 77 then use
the following commond
182_191_255_20(config-msag)#rtp mprb-parameter dtmf dtmfrelaymode 6
NOT RELAY.
VOICE CODING.
Red RFC2833.
AAL2/IETF.
nRed RFC2833.
3.14.
E1 cable
transmision
Subscriber cable
V35 cable
E1 analysis tester
2) Topo Logic
O
D
T
I
SDH
Network
H
D
B
MODEM
3) equipment preparing
1 SHDSL (X3208D) modem
2 Modem interface :V35
3 Test equipmenterror E1 analysis equipmentACTERNA E1 and Data EDT-135
4 HDB card hardware jumper wire config X12~X15X1223X1312X1412
X1512
32x64k
1
32
1 port mode is using maximum of 2mb circuit, if your using 1 port mode, it uses all timeslot
for 1 E1 i.e 32 timeslots, the command for configuring 1 port mode is :
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_32x64k
2 port mode i.e 2*n*64k
16x64k
16x64k
17
32
2 port mode is using maximum two 1mb circuits i.e 1mb circuit for first 16 timeslots (1-16 ts),
and 1mb circuit for other 16 timeslots (17-32 ts),the commands for configuring 2 port mode
is :
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k
msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_16x64k
3 port mode i.e 1*n*64k+2*m*64k
16x64k
1
17
8 x64k
8x64k
25
32
3 port mode can using maximum one 1mb circuit and two 512 kbs circuit , using 1-17
timeslots for 1mb, 17-25 time slots for 512kbs and 25-32 timeslots for other 512kbs,
commands for configuring 3 mode is :
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k
msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_8x64k
msag(config-msag) ddn port add hdb 5 25 type type_hdb subratetype subratetype_8x64k
Confidential and Proprietary Information of ZTE CORPORATION
8x64k
1
8x64k
8x64k
17
8x64k
25
32
4 port mode is using maximum four 512kbs circuits,i.e using first 1-9 timeslots for 512kbs,
other 9-17 timeslots 512kbs, other 17-25 for next 512kbs,similarly 25-32 timeslot for last
512kbs circuit,commands for 4 port mode is:
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k
msag(config-msag) ddn port add hdb 5 9 type type_hdb subratetype subratetype_8x64k
msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_8x64k
msag(config-msag) ddn port add hdb 5 25 type type_hdb subratetype subratetype_8x64k
2)
3)
4)
Step
Function
4*n*64K
Notes:
Create
DDN
HDBODTI
connection
from
ZXAN(config)#set-e1clktype EST2M
ZXAN#show e1clock
ODTI E1 loop
loop-back 1
3.15.
DDN config
manul.doc
DDN-test.doc
Softswitch
TRX Equipment
NT1
Subscriber cable
2) equipment preparing
1 ISDN
NT1
2) Interface ID (IID)
3) TID for ISDN user
3) ISDN service configure step
1) Add AS
2) Add ASP ,
3) Bind AS & ASP,
4) Configure D channel
5) Add TID for ISDN user
6) Add SCTP signal port
Notes:before configure ensure H248 is OK;check licence.dat
Number
Step
Function
ZXAN(config-msag)#as add 1
Add AS ;
instream 8 outstream 8
Same to Softswith;
ZXAN(config-msag)#asasp add 1 1
Bind AS&ASP;
ZXAN(config-msag)#show msag as
Check AS status
Add
3.16.
Step
Function
ZXAN(config-msag)#as add 1
Add AS ;
10.16.98.102
instream 8 outstream 8
Same to Softswith;
ZXAN(config-msag)#asasp add 1 1
Bind AS&ASP;
ZXAN(config-msag)#show msag as
Check AS status
Add
3.17.
PPPOE+ function
ZXAN(config)#pppoe-plus
enable
ZXAN(config)#interface adsl_2/11/2
ZXAN(config-if)#pppoe-plus enable pvc 1
ZXAN(config)#port-location ?
access-node-identifier
hostname
vlan
vlan-control
3.18.
Function switch
Function switch provides additional features which could adjust CPU to process certain type of
traffic and disable the process for certain type of traffic for exam you enable CPU to process
IGMP service but disable DDN service
182_191_255_32-ITR_DHKLH_MG#dir
Directory of flash:/
attribute
size
date
time
drwx
16384
JUL-06-2011
12:06:40
drwx
16384
AUG-22-2011
20:10:40
cfg
drwx
16384
AUG-29-2011
07:24:46
data
drwx
16384
FEB-18-2010 10:31:54
gponont
-rwx
8822
AUG-29-2011
error.log
drwx
16384
FEB-18-2010 13:48:32
user
-rwx
51645
JUN-10-2011 14:40:38
error.log.bak
07:29:50
name
img
ddirectory
r read
wwrite
Img
xexcute
ddirectory
drwx
Cfg
Startrun.dat saved in
r read
this directory
wwrite
xexcute
ddirectory
drwx
Data
r read
in this directory
wwrite
xexcute
ddirectory
drwx
Gponont
r read
wwrite
xexcute
182_191_255_32-ITR_DHKLH_MG#cd cfg
182_191_255_32-ITR_DHKLH_MG#dir
Directory of flash:/cfg
attribute
size
date
time
name
20:10:40
drwx
16384
AUG-22-2011
drwx
16384
JAN-01-1970
-rwx
676
FEB-18-2010 13:48:48
-rwx
236108
AUG-22-2011
-rwx
4096
JUL-14-2011
00:00:00
20:10:40
01:19:08
..
license.dat
startrun.dat
nvram.dat
Startrun.dat
Nvram.dat
//144.1.1.100/startrun.dat@root:root
you just have to configure FTP server attributes before you download this data
once you finish download this file open it in NOTEPAD and you will see:
#ZXMSAG V2.0 License File
#Comments must start with a '#' mark
#Supported by WuFeng, wu.feng3@zte.com.cn
#define LM_ITEM_START_H248
#define LM_ITEM_START_MGCP
((int) 1)
((int) 2)
#define LM_ITEM_START_V5
((int) 3)
#define LM_ITEM_START_ISDN
((int) 4)
#define LM_ITEM_START_E1_MNG
#define LM_ITEM_START_ISDN2B
#define LM_ITEM_START_SIP
1=1
2=1
3=1
4=1
5=1
6=1
7=1
1
Set the parameters as per requirement adjust it if required . before doing this please contact
zte if they allow then do it
LM_ITEM_START_H248
INT 1
1:enable 0:disable
LM_ITEM_START_MGCP
INT 2
1:enable 0:disable
LM_ITEM_START_V5
INT 3
1:enable 0:disable
LM_ITEM_START_ISDN
INT 4
1:enable 0:disable
LM_ITEM_START_E1_MNG
INT 5
1:enable 0:disable
LM_ITEM_START_ISDN2B
INT 6
1:enable 0:disable
LM_ITEM_START_SIP
INT 7
1:enable 0:disable
3.19.
STAND BY SS CONFIGURATIONS
ZXAN(CONFIG-MSAG)#mgc add
(TYPE 2 =hauwie TYPE 1 =ZTE)
Check
Check
3.20.
SHDSL configration
MSAGV3.1
SHDSL MODEM
SMARTBITS600B
2).
Hareware configration
GISB
slot 9
SHDSL CARD
GSDLB
slot 15
MODEM
TAILET 1608
SMARTBITS
SMARTBITS 600B
UPLINK SUBCARD
GEI
BLUE
ORANGE
GREEN
BROWN
WHITE
RED
BLACK
10
11
12
YELLOW
13
14
15
16
WHITEBLUE
17
18
19
20
REDBLUE
21
22
23
24
BLACKBLUE
25
26
27
28
YELLOWBLUE
29
30
31
32
GSDLB support 16 shdsl ports, the subscribe sequence is first 8 ports and last 8 ports
There is a connector box: RJ45 transfer to subscriber
RJ45
TRANSFERBOX
SUBSCRIBER
WHITEORANGE
BLUE
4TH
ORANGE
YELLOW
5TH
3).
WHITEGREEN
BLACK
3RD
BLUE
RED
6TH
WHITEBLUE
GREEN
7TH
GREEN
YELLOW
8TH
WHITEBROWN
BROWN
1ST
BROWN
WHITE
2ND
Software Configuration
config rack shelf
set data-path-mode
msag(config)#interface shdsl_1/15/1-16
msag(if-config)#data-path-mode efm
msag(config)#shdsl profile 2wire
msag(config)#interfaceshdsl_1/15/1-4
profile
interface shdsl_1/15/1-4
switchport mode hybrid
switchport default vlan 1000
interface fei_0/9/0
no shutdown
switchprot mode hybrid
negotiation auto
switchport defaut vlan 1000
status
smartbits
SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]
SpanConfCurrCondTargetMarginDown(0..10dB):[5]
SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]
SpanConfCurrCondTargetMarginUp(0..10dB):[5]
SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]
SpanConfUsedTargetMargins(0-default,1-custom):[0]
SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]
SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]
4). test 4wires and 2wires like above procedures;
NOTE
pls make sure the pin to port is correctif it is wrongmaybe linkstatus is okbut service not through