You are on page 1of 47

Confidential and Proprietary Information of ZTE CORPORATION

Integrated Access Gateway


ZXMSG5200 V3.1 Commissioning Guide

Preface
Welcome to use MSG5200 equipment.
If you have used 5200-V3.1 and previous versions, you have had a full knowledge of our
equipment and it may be an easy thing for you to configure this equipment.

You need to read

this guide carefully. If you have never used 5200 equipment, this guide provides you a quick
understanding of the equipment.

V 3.1
Made by liuxin 10125036
Mail:liu.xin71@zte.com.cn
Contact:03145111470

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

contents
Preface ...................................................................................................................................................... 1
commission guide ..................................................................................................................................... 3
1.

OverView of MSAG5200 ................................................................................................................ 3

2.

Hardware introduce .......................................................................................................................... 3

3.

2.1.

Card type and service .................................................................................................. 4

2.2.

Hardware connection................................................................................................... 5

Service Commission introduce......................................................................................................... 7


3.1.

Entering into Data Configuration Interface ................................................................. 8

3.2.

Delete original data ................................................................................................... 10

3.3.

configuring Physical Position .................................................................................... 11

3.4.

Upgradation the version ............................................................................................ 12

3.5.

HSI Service configuration ......................................................................................... 17

3.6.

IPTV Service configuration....................................................................................... 20

3.7.

VOIP service configuration ....................................................................................... 22

3.8.

NMS service configuration ....................................................................................... 25

3.9.

1+1 uplink protection LACP ............................................................................ 26

3.10.

1:1 uplink protection UAPS ............................................................................. 27

3.11.

Selfswitch function .................................................................................................... 28

3.12.

EPM configuration .................................................................................................... 29

3.13.

Second dail configuration .......................................................................................... 35

3.14.

DDN service configuration ....................................................................................... 36

3.15.

ISDN-BRI service configuration ............................................................................... 39

3.16.

ISDN PRI CONFIGURATIONS .............................................................................. 40

3.17.

PPPOE+ function ...................................................................................................... 41

3.18.

Function switch ......................................................................................................... 41

3.19.

STAND BY SS CONFIGURATIONS ...................................................................... 43

3.20.

SHDSL configration .................................................................................................. 43

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

commission guide
1. OverView of MSAG5200
MSAG is the access equipment of SS (soft switch equipment MGC). MSAG connects with
SS via H248 protocol (or MGCP). MSAG is made up of control cardmedia resources sub
card test card and several subscriber cards, converging with a certain amount of
narrowband analog phone access and broadband ADSL access. The phone services are
provided by SS and broadband services are provided by internet.

2. Hardware introduce

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

2.1. Card type and service


Card name

Type

Using Shelf/slot---function

GISB

Control and switch card

All shelves 9/10 slot;

Control and switch card

Slave shelves 9/10 slot;

GISE/GISB

with

out voip subcard

GISE only support Narrow band


service
GISB support both Narrow band
and Broad band services

VOIP subcard

Resource card for

Only install On main shelf GISB

VOIP ,GISB

card

card

accessory
ODTI

Octal digital interface card

Main shelf 8,11,12 slot,


subscriber cable is special,
for ISDN PRI / DDN/E1 service

HDB

High-speed digital

Main shelf 1~8,11~13 slot

subscriber card

Slave shelves need special version


for DDN/E1/SHDSL service

STD

HDB

card accessory

ALC

Analog line card

Only install On HDB card


All shelf 1~8,11-15 slot
for 32 Voip normal user

RALC

Reverse Analog line card

All shelf 1~8,11-15 slot


for 32 Voip Payphone User

TSLCE

Subscriber test card

Main shelf 16 slot


for 112 test

GELC

GVDL

DLCE

32-port integrated voice


data subscriber card

GISB shelf 1~8,11~15 slot

16-port VDSL subscriber


card

GISB shelf 1~8,11~15 slot

ISDN digital subscriber

all shelves 1~8,11~13 slot

card

GEI

1000 Mbps Ethernet


cascade
interface card

for 32 Voip/ADSL normal user

for 16 VDSL normal user

for ISDN BRI service

Main shelf uplink card backplane


subcard
for 2GE+2FE uplink

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

SUPI

Slave shelf uplink


interface card

Slave shelf uplink card backplane


subcard

Expansion shelf, for cascading,


without uplink function
MBSL

Backplane of the

Mother board for MSAG

dual-power rear outlet


shelf

2.2. Hardware connection


1) DIP switch(on backplan) :
MBSL----Master: ON:ON:OFF:OFF(0011)
MBSL----Slave: ON:ON:OFF:

ON(0010)

Following is Slave shelf dip switch configurations

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

2) Hw connection:
Master shelf ----Uplink card: GEI

X7 and X8 provide two 100 Mbps Ethernet electrical interfaces for


broadband service uplink.
X5 and X6 provide two 1000 Mbps Ethernet optial interfaces for
broadband service uplink.
X4 is used to connect broadband/narrowband cascade cables,
which provide 5 4 jack. Leave two rows of pins empty, and
then plug in the first cascade cable. Plug one cascade cable every
three rows. Four cascade cables are supported at most to connect
slave shelf ----Uplink card: SUPI to four slave shelves

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

X4 is used for cascading. The cascade cables provide 5 4 jack.


Leave the first two rows of pins empty. The third, fourth, fifth, and
sixth rows are used for FE broadband/narrowband uplink.
The ninth, tenth, eleventh, and twelfth rows are used for GE broadband/
narrowband uplink.
X1, X2, and X3 are only used to connect the backplanes

3) Fiber connection:
Fiber need connect with Swith/TXN;
check GISB BACT light change to green Flashing every half second The broadband

service is normal.
Also can using command to check uplink status
4) Subscriber cable connection:

Leave the first pin empty plug 3*8 cable connector then after that connector leave one
another pin plug another 3*8 cable connector, this for 1~16 user
Leave the last pin empty plug 3*8 cable connector then befor that connector leave
one another pin plug another 3*8 cable connector,this for 17~32 user
DSL service checking : GELC card ACT light change to green means DSL link up
VOIP service checking: ALC/RALC card hook light change to green means phone hook
up
Also can using command to check status

3. Service Commission introduce


Topology for commission

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


GISB card
Infront of MSAG

MSAG MBSL board


Console cable

Console cable

Cross cable

Cross cable
Laptop
Laptop

Preparing test equipment for commission


1) 2 Laptop (wftp;wireshark; Procomm Plus;VLC)
2) 1 ADSL 4 lan port modem;
3) Stubbox &TV;
4) Numbers of cross cables&console cables
5) Usb to s323 convertor for laptop

3.1. Entering into Data Configuration Interface


Console service: provide operationmaintenancedebuggingboot mode
Outband service: provide operation ,maintenance port ;connect GISB ethnet port
Inband service: provide operation,maintenance,service port;connect GEI uplink port

Diagram for configuration interface:

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


GISB card
MSAG MBSL board

Console cable

Network cable

Cross cable
Laptop

1) Power on the master shelf of the cabinet, and the two GISB are in positions. Make the
GISB in Slot 9 as the active card. All the data configurations below are based on the
situation where the Slot 9 is active. we recommend you set Slot 9 as active.
2) Enter the user name and password in serial port ;serial configure baud rate is 9600
Configure your laptop ip using 144.1.1.0/24 then telnet 144.1.1.1

using outband service

user name/passwordzte/zte

3) Enter into the data configuration interface ;


five mode:
ZXAN #; ZXAN (config)#; ZXAN (config-msag)#; ZXAN (version)#; ZXANconfig-if)#

See as below

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

Specifications on Data Configuration Interface


Interface

Function

Transfer

SHELL

Debugging output

exit

ZXAN #

Commands of show types can be

configure terminal

used.

Version transfer to ZXANversion)#

ZXAN (config)#

ZXAN (config-msag)#

Hardware and

broadband data

transfer to ZXAN (config)#

ZXAN transfer to ZXAN (config-MSAG)#;

configuration interface

Interface

x/x transfer to ZXAN (config-if)#

Narrowband data configuration

exit transfer to ZXAN#;

interface
ZXAN (version)#

Version configuration interface

exit transfer to ZXAN#

ZXAN (config-if)#

Sub interface configuration

exit transfer to (config)#

3.2. Delete original data


Numbe

Step

Function

ZXAN #cd cfg

Go to cfg folder

r
1

/cfg
2

ZXAN #dir

Check all the folder

ZXAN#del startrun.dat

delete broadband data

ZXAN #cd /

exit cfg folder,go to root folder

ZXAN # cd data

Go to data folder
/data

ZXAN #cd v0100

Go to V0100 folder
/data/v0100

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


7

ZXAN #del *.zdb

delete narrowband data in v0100 folder

ZXAN #cd /

Exit folder ,Go to root folder

ZXAN #cd data

Go to data folder
/data

10

ZXAN #cd v0101

Go to V0101 folder
/data/v0101

11

ZXAN #del *.zdb

delete narrowband data in v0101 folder

12

ZXAN (config) #reboot

Reboot system

Notes: all data running on flash, after reboot will reload save data; never do wr after you delete data

3.3. configuring Physical Position


Numbe

Step

Function

ZXAN (config) #add-rack rackno 1 racktype MSAG

Add Rack

ZXAN (config) #add-shelf rackno 1 shelfno 1 shelftype

Add Master Shelf

CTL_SHELF
3

ZXAN (config) #add-shelf rackno 1 shelfno 2 shelftype

Add Slave shelf

SLAVE_SHELF connectid 1

HW Connectid start from 1;

ZXAN (config) #add-shelf rackno 1 shelfno 3 shelftype

Shelf range (2-5);Connectid range

SLAVE_SHELF connectid 2

(1-4)

ZXAN (config) #add-card rackno 1 shelfno 1 slotno 3 ALC

Add user board for each service

ZXAN (config) #add-card rackno 1 shelfno 1 slotno 4 GELC

card for Master shelf


(ALC/RALC/DLCE/ODTI/HDB/G
ELC/GVDL)
Add user board for each service
card for Master shelf

ZXAN (config) #add-card rackno 1 shelfno 2 slotno 9 GISB

Add slave shelf Main control card

ZXAN (config) #add-card rackno 1 shelfno 3 slotno 3 GELC

GISE/GISB
Add slave shelf user board for each
service card
(ALC/RALC/DLCE/ODTI/HDB/G
ELC/GVDL)

ZXAN (config) #show card

Confidential and Proprietary Information of ZTE CORPORATION

Can check all card

Confidential and Proprietary Information of ZTE CORPORATION


7

ZXAN(config)#del-subcard slotno 9 subcardno 2

default value NO.2 subcard is


CNIC/MAPP,you need delete
this,add voip card to NO.2

ZXAN(config)#add-subcard slotno 9 subcardno 2 VOIP

default value NO.2 subcard is


CNIC/MAPP,you need delete
this,add voip card to NO.2

ZXAN(config)#show subcard

Check subcard 2voip online

10

ZXAN#write

Save data

Notes: Only after config rack system can start update version;uplink card GEI will be auto add by MSAG

3.4. Upgradation the version


1 Diagram for HSI configuration and troubleshooting

Ip add:144.1.1.100
Submask:255.255.255.0

Ethernet cable

Defult outband ip add:144.1.1.1


Submask:255.255.255.0

2 System FTP configuration

Number

Step

Function

ZXAN#config terminal

Shift to config mode

ZXAN(config)#show interface mng1

Display outband ip and ftp


configration

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


3

ZXAN(config)#interface mng1

Shift to management interface;

ZXAN(config-if)#boot-server 144.1.1.100

Both FTP username & Password

ZXAN(config-if)#boot-username target

must be same at both MSAG &

ZXAN(config-if)#boot-password target

FTP software
modify ftp server ip address;
modify ftp server username;
modify ftp server password;

ZXAN(config-if)#ex

Quit mng1 interface

ZXAN(config)#ex

Quit config mode

ZXAN#wri

Save config data

3 ftp server config

Run this ftp server software,you can see this windows as below:

Click security menu,choice users/rights

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

Click

Enter username uni,click OK

Enter password uni,click OK

Enter version file directory like as E:\version

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

Click Done,then minimum software window.


4 Update progress
Download version file to memery
Number

Step

Function

ZXAN#version

Shift to config mode

ZXAN(version)#download version

ics.bt

ZXAN(version)#download version

ics.fw

ZXAN(version)#download version

ics.mvr

ZXAN(version)#download version

voip_normal.fw

ZXAN(version)#download version

gise.bt

ZXAN(version)#download version

gise.mvr

ZXAN(version)#download version

gelca.bt

ZXAN(version)#download version

gelca.mvr

ZXAN(version)#download version

gdl.bt

ZXAN(version)#download version

gvdld.fw

ZXAN(version)#download version

gvdld.mvr

ZXAN(version)#download version

dti.bt

ZXAN(version)#download version

dti.mvr

ZXAN(version)#download version

dlce.mvr

Download dlce/tslceversion

ZXAN(version)#download version

tslce.mvr

Tslc use GDL.BT

Download GISB boot/version

Download GISE boot/version

Download gelca boot/version

Download gvdld boot/version

Download odti boot/version

as its boot

version
NotesALC/HDB no need version
update boot one-by-one slot for sevice card(except control card)
Number

Step

Function

ZXAN#version

Shift to config mode

ZXAN(version)#update-boot shelfno 1 slotno 3 local

Update boot for shelfno 1 slotno 3

ZXAN(version)#show update-status shelfno 1

Display update status,you can see


success or same versions

ZXAN(version)#update-boot shelfno 1 slotno 4 local

Update boot for shelfno 1 slotno 4

ZXAN(version)#show update-status shelfno 1

Display update status,you can see


success or same version

Same for all the service cards for all the shelves

. Update boot is slot by slot .

ZXAN(version)#update-boot shelfno 2 slotno 3 local

Update boot for shelfno 2 slotno 3

ZXAN(version)#show update-status shelfno 2

Display update status,you can see


success or same versions

ZXAN(version)#update-boot shelfno 3 slotno 3 local

Update boot for shelfno 3 slotno 3

ZXAN(version)#show update-status shelfno 3

Display update status,you can see


success or same versions

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


NotesALC/HDB no need version,this document only give the sample ,all configuration follow actually
situation
update version batch every shelf
Number

Step

Function

ZXAN#version

Shift to config mode

ZXAN(version)#update-version shelfno 1 local

Update version batch for shelfno 1

ZXAN(version)#show update-status shelfno 1

Display update status, you can see sucess

ZXAN(version)#update-version shelfno 2 local

Update version batch for shelfno 2

ZXAN(version)#show update-status shelfno 2

Display update status, you can see sucess

ZXAN(version)#update-version shelfno 3 local

Update version batch for shelfno 3

ZXAN(version)#show update-status shelfno 3

Display update status, you can see sucess

NotesAll configuration follow actually situation


update boot for main control card every shelf
Number

Step

Function

ZXAN#version

Shift to config mode

ZXAN(version)#update boot shelfno 1 slotno 9 local

Update version batch for shelfno 1


Display update status, you can see sucess

ZXAN(version)#update boot shelfno 2 slotno 9 local

Update version batch for shelfno 2


Display update status, you can see sucess

ZXAN(version)#update boot shelfno 3slotno 9 local

Update version batch for shelfno 3


Display update status, you can see sucess

NotesAll configuration follow actually situation


Update version for slave control card every shelf
Number

Step

Function

ZXAN#version

Shift to config mode

ZXAN(version)#main-backup version

Synchronization shelfno 1

synchronization shelfno 1

ZXAN(version)#show sync-status shelfno 1

Display syn status

ZXAN(version)#main-backup version

Synchronization shelfno 2

synchronization shelfno 2

ZXAN(version)#show sync-status shelfno 2

Display syn status

ZXAN(version)#main-backup version

Synchronization shelfno 3

synchronization shelfno 3
ZXAN(version)#show sync-status shelfno 3

Display syn status

NotesAll configuration follow actually situation


Check version every shelf
Number

Step

Confidential and Proprietary Information of ZTE CORPORATION

Function

Confidential and Proprietary Information of ZTE CORPORATION


1

ZXAN(version)#exit

Shift to config mode

ZXAN#show card

Display Card status

ZXAN#show version-running shelfno 1

Display old version,active version,

ZXAN#show version-running shelfno 2

This version store in flash

ZXAN#show version-running shelfno 3

ZXAN#show version-saved shelfno 1

Display new version,inactive version

ZXAN#show version-saved shelfno 2

This version store in memory

ZXAN#show version-saved shelfno 3

NotesAll configuration follow actually situation


Reboot shelf start from slave shelf
Number

Step

Function

ZXAN#reboot shelfno 4

After reboot ,check all cards status for

ZXAN#show card shelfno 4

shelf 4

ZXAN#reboot shelfno 3

After reboot ,check all cards status for

ZXAN#show card shelfno 3

shelf 3

ZXAN#reboot shelfno 2

After reboot ,check all cards status for

ZXAN#show card shelfno 2

shelf 2

ZXAN#reboot shelfno 1

Master shelf reboot ,need wait same time

ZXAN#show card

before all shelf running

NotesAll configuration follow actually situation

5 Simple trouble shooting


All Card not get up ,change the slot
Shelf not get up ,check DIP switch & HW cable connection

3.5. HSI Service configuration


1) Diagram for HSI configuration and toubleshooting

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

Bras

Soft Bras
Connect the laptop on
Spare FE Uplink port
TRX Equipment

Configure HSI VLAN untag


the Spare Uplink

Subscriber cable

Configure the Modem in


Bridge mode

Make a dialer in user


laptop and dial.

2) Preparing for starting configure HSI


equipment preparing
1 Laptopsoftwarewiresharksoftbras
2 4 port ADSL modem
3 Number of Network cables
4 Number of subscriber cables
Data preparing:
1) HSI vlan
2) PPPOE username & password

3) HSI configuration step


1) Create vlan
2) User port untag to this vlanuplink port tag to this vlan
3) Change PVC value same to modemenable PVC 1
4)

Change ADSL profile

Numbe

Step

Confidential and Proprietary Information of ZTE CORPORATION

Function

Confidential and Proprietary Information of ZTE CORPORATION


1

ZXAN (config)#vlan 402

Create vlan 402 (for create one by one)

ZXAN(config)#vlan database

Create vlan database (for create multi vlan

ZXAN(vlan)#vlan 101,201,301,3999,401

together)

ZXAN (config) #interface adsl_1/4/1-32

Configure the port transfer sub-interface using

ZXAN (config-if-range) #no shutdown

range

ZXAN(config-if-range) #switchport default vlan

Open this interface

101 pvc 1

Add first PVC 1 untag to Vlan 101,


when type default vlan

means pvid same to vid

ZXAN (config-if-range) #atm pvc 1 vpi 8 vci 81

Change the first PVC 1 ; VPI&VCI need same to

ZXAN (config-if-range) # PVC 1 enable

modem;
Enable the first PVC

ZXAN(config-if-range)#adsl profile def2m.prf

Apply adsl profile for link up rate


ADSL2+ can reach 24 M download speed
ADSL2+ can reach 1 M

ZXAN(config)#adsl profile xyz

upload speed

Creat and modify new adsl profile;profile name is


xyz

ZXAN(config)#interface gei_1/9/3
ZXAN(config-if)#switchport

Configure the uplink


vlan

Tag uplink to vlan 101,201,301,399,401

101,201,301,3999,401 tag

ZXAN(config-if)#no shutdown

Enable uplink port

ZXAN#show vlan 402

Check the vlan information include tag port &


untag port

ZXAN#show adsl port-info adsl_1/3/1

Check dsl service link up rate

ZXAN#show dsl interface adsl_1/3/1 pvc 1

Check port pvc status

10

ZXAN#show adsl port-config adsl_1/3/1

Check line profile for this adsl port

11

ZXAN#show runing

Check all the configuration

12

ZXAN#write

Save the data

Notes: all data configure need check again,show running will be more easy to check all the configuration
If configure 1+1 uplink using sgsmartgroup

4) Simple trouble shooting


1) Using one laptop to dialing ,another laptop connected spare FE port,configure
uplink to untag to HIS vlan first ;then using monitor session to capture the PPPOE
packet
2) Using one laptop to dialing, another laptop using softbras to simulate Bras,to check
this vlan is ok or not
Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

Authentication
software BRAS
failure testing methodsetting.doc
at MSAN.doc

3.6. IPTV Service configuration


1 Diagram for IPTV configuration and troubleshooting

Fiber

cable

Uplink network

subscribercable

Configure the Modem in Bridge mode


PVC same as MSAG

modem
LAN

cable

Audio/video

cable

STB

television

2 Preparing for starting configure IPTV


IPTV include two partlive channel&VOD
live channel: using multicast packet, protocol using IGMP;
function is see the live channel together
VOD : using unicast packet,protocol ;also using for stubbox authentication PPPOE
protocol
Function is register to Bras and also can see the movie
equipment preparing
1 Laptopsoftwarewiresharksoftbrasvlc
2 4 port ADSL modem
3 Number of Network cables
4 Number of subscriber cables
5 Stubbox & TV
Data preparing:
Live channel
1) Mvlan using 3999
2) Channel group
VOD
1) PPPOE username & password for VODneed provide by PTCL
2) VOD vlan
3 IGMP configuration step
Live channel
1) Create vlan
Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

2) Make the MVlan


3) Enable IGMP
4) Change IGMP mode to proxy
5) Add source port for IGMP
6) Add receive port for IGMP
7) Add group for IGMP
8) Add uplink port tag to MVlan
9) Mvlan translate VOD vlan to Mvlan
VOD vlan

1 Add user port PVC 2 untag to VOD vlan;Add uplink port tag to VOD Vlan
2 Change PVC 2 value same to modem;enable PVC 2
3 Add uplink port tag to MVlan
4 Change ADSL profile

IGMP configuration
Number

Step

Function

ZXAN (config)#vlan 3999

Create vlan 3999 for MVlan

ZXAN (config) # igmp mvlan 3999

Create MVLan

ZXAN (config) #igmp enable

Igmp global enable

ZXAN(config) #igmp mvlan 3999 work-mode proxy

Igmp work mode snooping/proxy

ZXAN (config) #igmp mvlan 3999 group 239.194.0.1 to

Set Iptv channel

239.194.0.170
5

ZXAN(config)#igmp mvlan 3999 source-port gei_1/9/3

Set iptv source port

ZXAN (config) #igmp mvlan 3999 receive-port

Set iptv receive port

adsl_1/5/1-32 pvc 2
7

ZXAN(config)#interface gei_1/9/3
ZXAN(config-if)#switchport vlan

Add uplink to this 3999 Mvlan & VOD


3999 tag

vlan also

ZXAN (config) #interface adsl_1/5/1-32

Enter ADSL port config mode

ZXAN (config-if-range) #no shutdown

Port enable

10

ZXAN (config-if-range) #switchport mode access

Set port mode access/trunk/hybrid


VOD part

11

12

ZXAN (config-if-range) #switchport default vlan 201 pvc

Add vlan to PVC2,PVID is 201

VOD part

ZXAN (config-if-range) #atm pvc 2 vpi 0 vci 35

Set pvc 2,VPI/VCI

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


ZXAN (config-if-range) # pvc 2 enable

PVC2 enable

13

ZXAN (config-if-range) #adsl profile def4m.prf

Set adsl port profile

14

ZXAN (config-if-range) # mvlan-translate 3999 to untag

Translate municast vlan 3999 to

pvc 2

ports PVID 201

Notes: all data configure need check again,show running will be more easy to check all the configuration

4 Simple trouble shooting


a)

VOD register failed


If STB fail to connect the server use PPPOE dialing trough computer and verify
username and password.

b) If PPPOE dialing fail through computer please verify VOD vlan

configuration.Using this document

IPTV
UNICAST AND
troubleshooting.doc
MULTICAST TESTING.doc

3.7. VOIP service configuration


1) Diagram for IPTV configuration and troubleshooting
Softswitch

TRX Equipment

Configure Monitor session


for uplink ,untag spare unlink
to capture magaco packet

Subscriber cable

2) Preparing data for starting config VOIP


Normally using H248 protocol
Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

equipment preparing
1) Phone
2) Number of Network cables
3) Number of subscriber cables
Data preparing:
1) SS type & IP address
2) VOIP protocol H248 or MGCPprotocol port 2944 for h248
3) TID for narrow band user and RTP resource
4) MSAG VOIP IP address and next hop;NAT protocol
5) VOIP vlan
3)

VOIP configuration step


1)

VOIP subcard should be ok,first time configure will be take long time 10~15 minuter

2)

Create VOIP vlan and bind vlan

3)

Set Softswitch(MGC) parameter

4)

Create MG bind with MGC

5)

Set MSAG voip ipaddress and set MSAG voip next hop

6)

Set NAT protocol for MSAG

7)

Create VOIP TID on each narrow band cards// HW:A

8)

Create RTP resource

9)

Add uplink port tag to VOIP vlan

ZTE: USER

10) Configure IP on VOIP vlan


Number

Step

Function

ZXAN(config)#del-subcard slotno 9 subcardno 2

Delete default subcard 2

ZXAN(config)#add-subcard slotno 9 subcardno 2 VOIP

Add voip card to subcard 2

ZXAN(config)#show subcard

Get VOIP subcard status should be OK

ZXAN(config)#vlan 301

Create VOIP vlan

ZXAN(config-vlan)#voip-bind

Bind VOIP media

ZXAN(config-vlan)#voip-ctrl

Bind VOIP signal

ZXAN(config-vlan)#exit

ZXAN#msag

Config softswitch(MGC)

ZXAN(config-msag)#mgc add 1 10.20.32.5 port 2944

Type 1 for zte ss

type 1

Type 2 for huawei ss

ZXAN(config-msag)#mg add 1 1 port 2944

Create MSAG bind with

parameter

Softswitch(MGC)
5

ZXAN(config-msag)#voip interface add ctrl-ip


10.63.86.113 ctrl-mask 255.255.255.0 media-ip

Confidential and Proprietary Information of ZTE CORPORATION

Set MSAG VOIP IPaddress

Confidential and Proprietary Information of ZTE CORPORATION


10.63.86.113 media-mask 255.255.255.0 route-mode 2

ZXAN(config-msag)#voip route add 10.63.86.254

Set MSAG VOIP next hop

ZXAN(config-msag)#media-nat add 9 1 9 5 5

Add NAT protocol for RTP translater

10.63.86.113 10000

Nat

ZXAN(config-msag)# slc terminationid add rackno 1

ZTE Softswitch TID must using

shelfno 1 3 USER type 3 begin-no 0 digit-length 4

USER0000~USER00XX..ETC

port start from 10000

mgid 1

ZXAN(config-msag)# slc terminationid add rackno 1

HW Softswitch TID must use

shelfno 1 7 A type 2 begin-no 0

A0~Axxx

ZXAN(config-msag)# rtp terminationid add RTP

Add RTP resources if ZTE SS must

begin-seqno 1 240 type 3

start RTP000~RTP0XX

ZXAN(config-msag)#rtp terminationid add RTP/

Add RTP resource if HW ss must start

begin-seqno 1 240

RTP/0~RTP/xx

ZXAN(config)#interface gei_1/9/3

Add uplink port to VOIP vlan

ZXAN(config-if)#switchport vlan

301

tag

ZXAN(config)#interface vlan 301

Configure this IP on this vlan .

ZXAN(config-if)#ip address 10.63.86.113

Ping next hope to check your config

255.255.255.0
ZXAN(config-if)#exit
ZXAN(config)# ip route 10.0.0.0 255.0.0.0
10.63.86.254 (vrrp ip , voip next hope )

ZXAN#show vlan 312

Add

route to PING SS ,

Now Ping SS ip

verify that up link tagged over VOIP


VLAN.

ZXAN#show msag mgc

verify that SS parameter is


configured properly or not

ZXAN#show msag mg

vertify Mg configure properly or


not

ZXAN#show msag voip-ipaddr

check MSAG VOIP address and next


hop

ZXAN#show msag allnat

check NAT parameter

ZXAN#show msag rtp terminationid

check RTP

ZXAN#show msag slc terminationid shelf 1 3

check TID

ZXAN#show msag h248-status

check H248 status

Notes: all data configure need check again,show running will be more easy to check all the configuration

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION


4)

Simple trouble shooting


1) Using wireshark to capture uplink packet to check H248 packet (Megaco),
monitor session for this spare uplink port
2) Ping SS IP address ZXAN# ping 10.16.98.102

3.8. NMS service configuration


1) Diagram for NMS configuration and troubleshooting

Uplink network

Fiber cable

LAN cable-outband
Serial cable-console port

terminal

2) Preparing data for starting config nms


1) NMS vlan
2) NMS IPaddress for MSAG
3) NMS Next hop
Number

Step

Function

ZXAN(config)#interface gei_1/9/4

Enter GE port config mode

ZXAN(config-if)#switchport vlan 401 tag

Create FE port VID connect uplink port

ZXAN(config-if)#exit

Quit to global config mode

ZXAN(config)#interface vlan 401

Enter vlan config mode

ZXAN(config-if)#ip address 10.100.10.10

Create L3 ip address

255.255.255.0
6

ZXAN(config-if)#exit

Quit to global config mode

ZXAN(config)#ip route 10.0.0.0 255.0.0.0

Create ip route information,nexthop and

10.100.10.1

network

ZXAN#ping 10.100.10.1

Ping

Notes:You can ping nexthop ip address


Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

ZXAN#ping 10.100.10.1
sending 5,100-byte ICMP echos to 10.100.10.1,timeout is 2 seconds.
!!!!!
Success rate is 100 percent(5/5),round-trip min/avg/max= 0/8/40 ms.
3) Simple trouble shooting
1) Using spare FE uplink to connect one laptop ,configure this spare port in NMS vlan
Configure Laptop ipaddress same to NMS next hop IP
2) Ping MSAG using laptop

NMS.doc

3.9. 1+1 uplink protection LACP


Using 2 GE uplink to meet load sharing with traffic

LACP configuration step


1 Create Smartgroup
2 2 GE uplink must same using same vlan
3 Add smartgroup in these vlan same configuration with

GE uplink

Number

Step

Function

ZXAN(config)#interface smartgroup1

create smartgroup 1

ZXAN(config-if)#switchport vlan 401 tag

add this smartgroup to this vlan

ZXAN(config-if)exit

ZXAN(config)#interface fei_1/9/3

Add uplink to this vlan

ZXAN(config-if)#switchport vlan 401 tag


ZXAN(config-if)#smartgroup 1 mode active

Smartgroup mode have three

ZXAN(config)#interface fei_1/9/4

Activepassiveon

ZXAN(config-if)#switchport vlan 401 tag

LACP using active mode

ZXAN(config-if)#smartgroup 1 mode active

Trunk using on mode


Our suggestion active mode

ZXAN(config)#show lacp internal

Simple trouble shooting


ZXAN(config)#show lacp internal

Confidential and Proprietary Information of ZTE CORPORATION

Check LACP status

Confidential and Proprietary Information of ZTE CORPORATION

Smartgroup:1
Flag *--LOOP is TRUE
Actor

Agg

Port

State

LACPDUs

Port

Oper

Interval Priority Key

Port

RX

Mux

State Machine

Machine

----------------------------------------------------------------------------gei_1/9/3

selected

30

32768

0x103

0x3d

current

distributing

gei_1/9/4

selected

30

32768

0x103

0x3d

current

distributing

if you see two port are all select, means the one plus one function is OK, you can do the
test!

1:1 uplink protection UAPS

3.10.

Uplink network

gei_1/11

gei_1/11
VRRP ipaddress:10.10.10.3/24
gei_1/10

gei_1/10
VLAN 300 interface
gei_2/22
ipaddress:10.10.10.1/24

gei_2/22

gei_1/9/3

VLAN 300 interface


ipaddress:10.10.10.2/24

gei_1/9/4

AG

VLAN plan:
100 HSI
200 NMS
300 VOIP
IP plan:
NMS 12.12.12.254/24 nexthop 12.12.12.1/24
VOIP 10.10.10.254/24 nexthop 10.10.10.3/24

modem

Number

Step

Function

ZXAN#configure termianal

Create uplink protection group

ZXAN(config)#uaps-group 1
2

ZXAN(cfg-uaps-1)#port

master-port

gei_1/9/4

add port to protection group


(1/9/4

slave-port gei_1/9/3

active,

1/9/3

for

standby)

ZXAN(cfg-uaps-1)#next-hop

10.10.10.3

media

Confidential and Proprietary Information of ZTE CORPORATION

link-type

Set up to detect link type


(media or normal), can examine

Confidential and Proprietary Information of ZTE CORPORATION

the next-hop ok or not.


ZXAN(config)#show uaps
Group List :
--------------------------------------Group List :
--------------------------------------1
ZXAN(config)#show uaps groupid 1

3.11.

Revertive control

: disable

Next-hop

: 10.10.10.3

Link-type

: media

Link-detect-retry

: 5

Link-detect-interval

: 3

Link status

: connected or NA

Bfd next_hop

: 0.0.0.0

Bfd

: connected or NA

Link status

Switch-type

: common port

Master ports status

: block

Slave ports status

: forwarding gei_1/9/4 : up

gei_1/9/3 : up

Selfswitch function

Dont need connect Softswitch can make dail


Selfswitch configure step
1) Add-phone number
2) Add-digitmap
3) Self-exchange configuration
Number

Step

Function

ZXAN (config-msag) #SLC phone-number modify 3

Add selfswitch phone number

begin-index 1 num 16 begin-phone-number 88801

ZXAN (config-msag) #show msag slc phone-number

Get result

ZXAN (config-msag) #SLC phone-number del

Delete selfswitch phone number

ZXAN (config-msag) #digitmap add 1 SELFDM digit-map

Digitmap must follow the number

888XX servicetype 1

Like phone number 8888,so digitmap


need 8xxx;

ZXAN (config-msag)#MG capability 1 self-exchange 1

Enable self exchange

ZXAN (config-msag)#mg parameter 1 link-kept-time 10

Change H248 linkdown time

ZXAN(config-msag)#show msag mg parameter mgid 1

Check the result

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

ZXAN (config-msag) #mgc type modify 2 dm-long 15

Change dial tone time

ZXAN (config-msag) #mgc type modify 2 dm-start 15


ZXAN (config-msag) #show msag mgc type mgctype 2

3.12.

Check the result

EPM configuration

Creat SNMP TRAP SERVER first use the following command set to set SNMP TRAP
SERVER
Zxan(config)#snmp-server host 116.71.241.228 trap
version

2c

public

enable

MSAG SERVER IN H-9

NOTIFICATIONS

server-index 1 udp-port 162


Zxan(config)#snmp-server host 119.153.44.116 trap
version

2c

public

enable

SNMP TRAP SERVER IN PTCL NOC

NOTIFICATIONS

server-index 2 udp-port 162


Zxan(config)#snmp-server host 144.1.1.100
version

2c

private

enable

trap

FOR LOCAL CHECK DURING PRE PAT

NOTIFICATIONS

server-index 3 udp-port 162


Show snmp config

ZXAN(config)#fan-epm-console epm
Show fan-epm-console
1. Create EPM unit on nms

2. Choose the NE, click create button

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

3. you will see EPM in the bottom of the rack map

4. config environment sensor

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

5,only need config the sensor 1 , after this , you can test if all the sensor works well

6,config the power unit

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

7,click

create button

8. COM No usually be 2 , the power type depend on which type of power the site use, then
create OK

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

9,then at here you will see the temperature , humidity , AC, DC, battery sensor value

10, you can config the sensors threshold at here

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

11,for test the temperature sensor , you can config the upper value very low

10. power threshold config , config 52 for battery and DC voltage test

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

11,here to check all the environment and power alarm

3.13.

Second dail configuration

182_191_255_20(config-msag)#rtp mprb-parameter dtmf dtmfrelaymode 1

choose viice

coding,
If you still find issue in dialing phone numbers like 1218, 080080800 , 1217, 131 777 77 then use
the following commond
182_191_255_20(config-msag)#rtp mprb-parameter dtmf dtmfrelaymode 6

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

NOT RELAY.

VOICE CODING.

Red RFC2833.

AAL2/IETF.

nRed RFC2833.

3.14.

DDN service configuration

1) Diagram for NMS configuration and troubleshooting

E1 cable

transmision

Subscriber cable

V35 cable

E1 analysis tester

2) Topo Logic

O
D
T
I

SDH
Network

H
D
B

MODEM

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

3) equipment preparing
1 SHDSL (X3208D) modem
2 Modem interface :V35
3 Test equipmenterror E1 analysis equipmentACTERNA E1 and Data EDT-135
4 HDB card hardware jumper wire config X12~X15X1223X1312X1412
X1512

5 ODTI card hardware jumper wire config X10-X25:12---75ohm,23---120ohm


4) DDN service configure step
1)

Configure HDB work mode

1 port mode i.e 1*n*64k

32x64k
1
32
1 port mode is using maximum of 2mb circuit, if your using 1 port mode, it uses all timeslot
for 1 E1 i.e 32 timeslots, the command for configuring 1 port mode is :
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_32x64k
2 port mode i.e 2*n*64k

16x64k

16x64k

17

32
2 port mode is using maximum two 1mb circuits i.e 1mb circuit for first 16 timeslots (1-16 ts),
and 1mb circuit for other 16 timeslots (17-32 ts),the commands for configuring 2 port mode
is :
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k
msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_16x64k
3 port mode i.e 1*n*64k+2*m*64k

16x64k
1

17

8 x64k

8x64k
25

32

3 port mode can using maximum one 1mb circuit and two 512 kbs circuit , using 1-17
timeslots for 1mb, 17-25 time slots for 512kbs and 25-32 timeslots for other 512kbs,
commands for configuring 3 mode is :
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k
msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_8x64k
msag(config-msag) ddn port add hdb 5 25 type type_hdb subratetype subratetype_8x64k
Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

4 port mode 4*n*64k

8x64k
1

8x64k

8x64k

17

8x64k
25

32

4 port mode is using maximum four 512kbs circuits,i.e using first 1-9 timeslots for 512kbs,
other 9-17 timeslots 512kbs, other 17-25 for next 512kbs,similarly 25-32 timeslot for last
512kbs circuit,commands for 4 port mode is:
msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k
msag(config-msag) ddn port add hdb 5 9 type type_hdb subratetype subratetype_8x64k
msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_8x64k
msag(config-msag) ddn port add hdb 5 25 type type_hdb subratetype subratetype_8x64k
2)

Create DDN port for HDB

3)

Create DDN port for ODTI

4)

Create DDN connection from HDBODTI


Number

Step

Function

ZXAN(config-msag)#ddn hdb portnum modify 3 portnum

Configure HDB work mode

4*n*64K

Notes:

it can using 4 ports

First port is 24A/24Csecond port is


26A/26Cthird port is 28A/28C
fourth port is 30A/30C

ZXAN(config-msag)# ddn port add HDB shelf 3 4 1 type

Create DDN port for HDB

type_hdb subratetype subtype_3x64k


3

ZXAN(config-msag)#ddn port add ODTI shelf 1 8 1 type

Create DDN port for ODTI

type_odti subratetype subtype_3x64k ts 1

Notestotal 364Konly can bind 1


E1 ,start must from ts 1

ZXAN(config-msag)#ddn connection add 1 PortName1 HDB

Create

DDN

PortName2 ODTI DDN--HBL

HDBODTI

connection

from

Notes:using name to bind each other

ZXAN(config)#set-e1clktype EST2M

Confidential and Proprietary Information of ZTE CORPORATION

Set clock source

Confidential and Proprietary Information of ZTE CORPORATION


6

ZXAN#show msag ddn connection

check DDN connect

ZXAN#show msag ddn hdb portnum shelf 3 4

check work mode

ZXAN#show msag ddn port shelf 1 slot 8

check DDN port(ODTI)

ZXAN#show msag ddn port shelf 3 slot 4

check DDN port(HDB)

ZXAN#show e1clock

check clock source

ZXAN(config-msag)#pcm attribution modify 8 1

ODTI E1 loop

loop-back 1

Simple trouble shooting

Test way pls check this document

3.15.

DDN config
manul.doc

DDN-test.doc

ISDN-BRI service configuration

1) Diagram for NMS configuration and troubleshooting

Softswitch

TRX Equipment

Configure Monitor session


for uplink ,untag spare unlink
to capture magaco packet

NT1

Subscriber cable

2) equipment preparing
1 ISDN

NT1

2 Connect Phone with DLCE card


ISDN parameter preparing
1) Desport 6100 ;local port 2905

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

2) Interface ID (IID)
3) TID for ISDN user
3) ISDN service configure step
1) Add AS
2) Add ASP ,
3) Bind AS & ASP,
4) Configure D channel
5) Add TID for ISDN user
6) Add SCTP signal port
Notes:before configure ensure H248 is OK;check licence.dat
Number

Step

Function

ZXAN(config-msag)#as add 1

Add AS ;

ZXAN(config-msag)#asp add 1 6100 2905 1 10.16.98.102

Add ASP set parameter for ASP need

instream 8 outstream 8

Same to Softswith;

ZXAN(config-msag)#asasp add 1 1

Bind AS&ASP;

ZXAN(config-msag)#show msag as

Check AS status

ZXAN(config-msag)#show msag asp

Check ASP status

ZXAN(config-msag)#isdn dlink span add 7 1 1 100 1

Add

ZXAN(config-msag)#show msag isdn dlink attribute

Check ISDN Dlink status

ZXAN(config-msag)#show msag slc terminationid 7

Check ISDN BRI terminal ID

ZXAN(config-msag)#slc terminationid add 7 BRA 1

Add ISDN BRI user terminal ID

ZXAN(config-msag)#ctrlport add 1 6610 info 1

Add ctrl port

Dlink,IID must same to SS

4) Simple trouble shooting


1) First AS & ASP

need active ,check parameter with SS

2) Then capture the signal to check

3.16.

ISDN PRI CONFIGURATIONS


Number

Step

Function

ZXAN(config-msag)#as add 1

Add AS ;

ZXAN(config-msag)#asp add 1 6100 2905 1

10.16.98.102

Add ASP set parameter for ASP need

instream 8 outstream 8

Same to Softswith;

ZXAN(config-msag)#asasp add 1 1

Bind AS&ASP;

ZXAN(config-msag)#show msag as

Check AS status

ZXAN(config-msag)#show msag asp

Check ASP status

ZXAN(config-msag)#isdn dlink span add 8 pcm-no 1 1 17 1 1

Add

Dlink,IID must same to SS

17 is the index for version 3


ZXAN(config-msag)#show msag isdn dlink attribute

Confidential and Proprietary Information of ZTE CORPORATION

Check ISDN Dlink status

Confidential and Proprietary Information of ZTE CORPORATION


3

ZXAN(config-msag)#show msag trunk terminationid 8 1

Check ISDN PRI terminal ID

ZXAN(config-msag)#trunk terminationid add 8 1 A

Add ISDN PRI user terminal ID

begain-no 4001 type 2


4

3.17.

ZXAN(config-msag)#ctrlport add 1 9899 info 1

Add ctrl port

PPPOE+ function

ZXAN(config)#pppoe-plus

enable

ZXAN(config)#interface adsl_2/11/2
ZXAN(config-if)#pppoe-plus enable pvc 1
ZXAN(config)#port-location ?
access-node-identifier

Config access-node-identifier info

hostname

Config port-location hostname

vlan

Config specific vlan

vlan-control

3.18.

Config vlan control

Function switch

Function switch provides additional features which could adjust CPU to process certain type of
traffic and disable the process for certain type of traffic for exam you enable CPU to process
IGMP service but disable DDN service

This file could be accessed by attaining the LICENSE.DAT placed

inside CFG folder

182_191_255_32-ITR_DHKLH_MG#dir
Directory of flash:/
attribute

size

date

time

drwx

16384

JUL-06-2011

12:06:40

drwx

16384

AUG-22-2011

20:10:40

cfg

drwx

16384

AUG-29-2011

07:24:46

data

drwx

16384

FEB-18-2010 10:31:54

gponont

-rwx

8822

AUG-29-2011

error.log

drwx

16384

FEB-18-2010 13:48:32

user

-rwx

51645

JUN-10-2011 14:40:38

error.log.bak

07:29:50

name
img

64880640 bytes total (43188224 bytes free)


drwx

ddirectory
r read
wwrite

Confidential and Proprietary Information of ZTE CORPORATION

Img

Version saved in this


directory

Confidential and Proprietary Information of ZTE CORPORATION

xexcute
ddirectory

drwx

Cfg

Startrun.dat saved in

r read

this directory

wwrite
xexcute
ddirectory

drwx

Data

Narrowband data saved

r read

in this directory

wwrite
xexcute
ddirectory

drwx

Gponont

Gpon ont version saved

r read
wwrite
xexcute

182_191_255_32-ITR_DHKLH_MG#cd cfg
182_191_255_32-ITR_DHKLH_MG#dir
Directory of flash:/cfg
attribute

size

date

time

name

20:10:40

drwx

16384

AUG-22-2011

drwx

16384

JAN-01-1970

-rwx

676

FEB-18-2010 13:48:48

-rwx

236108

AUG-22-2011

-rwx

4096

JUL-14-2011

00:00:00

20:10:40
01:19:08

..
license.dat
startrun.dat
nvram.dat

64880640 bytes total (43188224 bytes free)


License.dat

There are many functions which defined by


this file, H248,MGCP,DDN,ISDN etc.

Startrun.dat

Broadband data file, rack,shelf,card,etc.

Nvram.dat

Boot parameter, outband ip, mac,etc.

You can download it by using this command


ZXAN#copy flash: /cfg/license.dat ftp:

//144.1.1.100/startrun.dat@root:root

you just have to configure FTP server attributes before you download this data
once you finish download this file open it in NOTEPAD and you will see:
#ZXMSAG V2.0 License File
#Comments must start with a '#' mark
#Supported by WuFeng, wu.feng3@zte.com.cn
#define LM_ITEM_START_H248
#define LM_ITEM_START_MGCP

((int) 1)
((int) 2)

Confidential and Proprietary Information of ZTE CORPORATION

/*whether or not enable H.248 services*/


/*whether or not enable MGCP services*/

Confidential and Proprietary Information of ZTE CORPORATION

#define LM_ITEM_START_V5

((int) 3)

/*whether or not enable V5 services*/

#define LM_ITEM_START_ISDN

((int) 4)

/*whether or not enable ISDN services*/

#define LM_ITEM_START_E1_MNG

((int) 5) /*e1 management*/

#define LM_ITEM_START_ISDN2B

((int) 6) /*ISDN2B Term */

#define LM_ITEM_START_SIP

((int) 7) /*whether or not enable SIP services*/

1=1
2=1
3=1
4=1
5=1
6=1
7=1
1

is for enabling any feature and

is to disable any feature.

Set the parameters as per requirement adjust it if required . before doing this please contact
zte if they allow then do it
LM_ITEM_START_H248

INT 1

1:enable 0:disable

LM_ITEM_START_MGCP

INT 2

1:enable 0:disable

LM_ITEM_START_V5

INT 3

1:enable 0:disable

LM_ITEM_START_ISDN

INT 4

1:enable 0:disable

LM_ITEM_START_E1_MNG

INT 5

1:enable 0:disable

LM_ITEM_START_ISDN2B

INT 6

1:enable 0:disable

LM_ITEM_START_SIP

INT 7

1:enable 0:disable

3.19.

STAND BY SS CONFIGURATIONS

Use following commands to set stand by SOFT SWITCH whenever required

ZXAN(CONFIG-MSAG)#mgc add
(TYPE 2 =hauwie TYPE 1 =ZTE)

2 10.20.16.2 port 2944 type 2


ZXAN(CONFIG-MSAG)# mg modify 1 1
mgcid2 2 port 2944
Show msag mg

Check

Show msag mgc

Check

3.20.

SHDSL configration

1). Test Enviroment

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

MSAGV3.1
SHDSL MODEM

SMARTBITS600B

2).

Hareware configration

Main control card

GISB

slot 9

SHDSL CARD

GSDLB

slot 15

MODEM

TAILET 1608

SMARTBITS

SMARTBITS 600B

UPLINK SUBCARD

GEI

32 subscriber pin to port


M

BLUE

ORANGE

GREEN

BROWN

WHITE

RED

BLACK

10

11

12

YELLOW

13

14

15

16

WHITEBLUE

17

18

19

20

REDBLUE

21

22

23

24

BLACKBLUE

25

26

27

28

YELLOWBLUE

29

30

31

32

GSDLB support 16 shdsl ports, the subscribe sequence is first 8 ports and last 8 ports
There is a connector box: RJ45 transfer to subscriber
RJ45

TRANSFERBOX

SUBSCRIBER

WHITEORANGE

BLUE

4TH

ORANGE

YELLOW

5TH

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

3).

WHITEGREEN

BLACK

3RD

BLUE

RED

6TH

WHITEBLUE

GREEN

7TH

GREEN

YELLOW

8TH

WHITEBROWN

BROWN

1ST

BROWN

WHITE

2ND

Software Configuration
config rack shelf

add rack shelf cards

set data-path-mode

msag(config)#interface shdsl_1/15/1-16

create shdsl profile

msag(if-config)#data-path-mode efm
msag(config)#shdsl profile 2wire

modem only support


efm mode
create 4wire and 8wire
like this

Apply profile to ports

msag(config)#interfaceshdsl_1/15/1-4

we use default alarm

shdsl profile 2wire

profile

shdsl alarm profile sdefval.prf


Config uplink and shdsl
ports

interface shdsl_1/15/1-4
switchport mode hybrid
switchport default vlan 1000
interface fei_0/9/0
no shutdown
switchprot mode hybrid
negotiation auto
switchport defaut vlan 1000

set modem with 8wire

Pls check modem configuration docx

check the synchronize

show shdsl port-status shdsl_1/15/1

status
smartbits

Send and receive packet for testing

MSAG(CONFIG)#shdsl profile 2wire


SpanConfWireInterface(1-twoWire,2-fourWire,3-sixWire,4-eightWire):[1]
SpanConfMinLineRate(192..30000kbps):[200]
SpanConfMaxLineRate(200..30000kbps):[6000]
SpanConfPSD(1-symmetric,2-asymmetric):[1]
SpanConfTransmissionMode(0-default,1-custom):[0]
SpanConfRemoteEnabled(1-enable,2-disable)):[1]

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]
SpanConfCurrCondTargetMarginDown(0..10dB):[5]
SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]
SpanConfCurrCondTargetMarginUp(0..10dB):[5]
SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]
SpanConfUsedTargetMargins(0-default,1-custom):[0]
SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]

MSAG(CONFIG)#shdsl profile 4wire


SpanConfWireInterface(1-twoWire,2-fourWire,3-sixWire,4-eightWire):[2]
SpanConfMinLineRate(192..30000kbps):[200]
SpanConfMaxLineRate(200..30000kbps):[6000]
SpanConfPSD(1-symmetric,2-asymmetric):[1]
SpanConfTransmissionMode(0-default,1-custom):[0]
SpanConfRemoteEnabled(1-enable,2-disable)):[1]
SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]
SpanConfCurrCondTargetMarginDown(0..10dB):[5]
SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]
SpanConfCurrCondTargetMarginUp(0..10dB):[5]
SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]
SpanConfUsedTargetMargins(0-default,1-custom):[0]
SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]

MSAG(CONFIG)#shdsl profile 8wire


SpanConfWireInterface(1-twoWire,2-fourWire,3-sixWire,4-eightWire):[4]
SpanConfMinLineRate(192..30000kbps):[200]
SpanConfMaxLineRate(200..30000kbps):[6000]
SpanConfPSD(1-symmetric,2-asymmetric):[1]
SpanConfTransmissionMode(0-default,1-custom):[0]
SpanConfRemoteEnabled(1-enable,2-disable)):[1]
SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]
SpanConfCurrCondTargetMarginDown(0..10dB):[5]
SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]
SpanConfCurrCondTargetMarginUp(0..10dB):[5]
SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]
SpanConfUsedTargetMargins(0-default,1-custom):[0]

Confidential and Proprietary Information of ZTE CORPORATION

Confidential and Proprietary Information of ZTE CORPORATION

SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]
SpanConfLineProbeEnable(1-disable,2-enable):[1]
4). test 4wires and 2wires like above procedures;
NOTE
pls make sure the pin to port is correctif it is wrongmaybe linkstatus is okbut service not through

G,SHDSL TAINET Cable order.xlsx