Professional Documents
Culture Documents
SSR
UP SERIES
CCN:
23753403
Rev.:
C
Ref.:
9904
Page:
98
Date:
01st January 2011
Cancels: 10th January 2008
Point of Manufacture - Campbellsville, Kentucky USA
SSR UP6-15-125 , UP6-15-150
60 HERTZ ENGINEERING DATA
Model
15-125
cfm (m/min)
psig (barg)
psig (barg)
F ( C )
F ( C )
dB(A)
COOLING DATA
Air-cooled (Ambient Temperature 122F/50C)
Rated Airend Discharge temperature
F (C)
A/E Injection Temperature
F (C)
Aftercooler - Inlet (3)
F (C)
Aftercooler - Outlet
F (C)
Heat Removal Oil Cooler
1000 Btu/hr (kW)
Heat Removal Oil and Aftercooler
1000 Btu/hr (kW)
Oil Flow
US gpm (lpm)
Fan Air Flow
cfm (m/min)
Cooling Air CTD
F (C)
Aftercooler CTD ( 3 )
F (C)
(1.85)
(8.5)
(4.5)
(40)
(2)
58
150
65
105
36
68
199.0
180
172
126
32.2
42.0
7.0
1770
20
22
(93)
(82)
(78)
(52)
(9.4)
(12.3)
(15.9)
(50.1)
(12)
(12)
(1.64)
(10.3)
(4.5)
(40)
(2)
68
196.0
180
172
123
37.9
42.0
9.2
1770
20
19
(91)
(82)
(78)
(52)
(11.1)
(12.3)
(21.6)
(50.1)
(12)
(11)
PIPING CONNECTIONS
Air Discharge Base Mount
Air Discharge from Receiver
Coolant Drain
Power Inlet
Inches NPT
Inches NPT
Ball Valve -Inch NPT
Inches
DIMENSIONS
length, width, height
65
125
65
105
36
15-150
1.0
1.0
1.0
1.0
US Gal
US Gal
1.82 ( 7.0 )
3.38 ( 13.0 )
1.82 ( 7.0 )
3.38 ( 13.0 )
Inches
mm
Base Mounted
52 / 36 / 42.5
1321/ 914/ 1080
lb. (kg)
Base Mounted
1183 ( 538 )
ENGINEERING MANUAL
SSR
UP SERIES
CCN:
23753403
Rev.:
C
Ref.:
9904
Page :
99
Date:
01st January 2011
Cancels: 10th January 2008
Point of Manufacture - Campbellsville, Kentucky USA
SSR UP6-15-125 , UP6-15-150
60 HERTZ ENGINEERING DATA
Model
15-125
15-150
4.21
2335
42.92
4.21
2093
38.47
AIREND DATA
Rotor Diameter ( male )
Male Rotor Speed
Tip Speed
inches
rpm
ft/sec
Motor Enclosure
Nominal Current - Drive Motor ( 8 )
Package Current - maximum pressure
Drive Motor RPM
Drive Motor Frame
Drive Motor Full Voltage Locked Rotor ( star ) Amps ( 7 )
Drive Motor Efficiency ( 10 )
Drive Motor Power Factor ( 10 )
Test certificate number
hp
hp
hp
Amps
Amps
200v
230v
380v
460v
575v
15.0
15.0
15.0
15.0
15.0
ODP
TEFC
ODP
TEFC
ODP
TEFC
ODP
TEFC
ODP
TEFC
43
47.3
1765
254T
257.6
0.91
0.81
41.1
45.2
1760
160M
(151.3)
0.91
0.85
37.4
41.2
1765
254T
224.0
0.91
0.81
35.7
39.3
1760
160M
(131.6)
0.91
0.85
22.6
24.9
1765
254T
135.6
0.91
0.81
21.7
23.8
1760
160M
(114)
0.91
0.85
18.7
20.6
1765
254T
112.0
0.91
0.81
17.9
19.7
1760
160M
(66.4)
0.91
0.85
15
16.4
1765
254T
89.6
0.91
0.81
14.3
15.8
1760
160M
(53.1)
0.91
0.85
01562/03
32765/02
01562/03
32765/02
TBA
TBA
01562/03
32765/02
01562/03
32765/02
4
90
4
90
4
80
4
80
10
40
10
40
10
40
10
40
10
35
10
35
Electrical Installation
Mains Supply Cable ( 8 )(13)
Suggested Fuse Rating
Gage
Amps
Grams / (Oz)
Filter Data
Primary filter detail - at 21oC ( 70oF )
CCN
85570588
ISO Class
C (F)
8C (46oF)
320/(11.6)
Particulate
barG / (psig)
barG / (psig)
barG / (psig)
barG / (psig)
Liquid
ISO Class
Filtration
ISO Class
1 micron
barG
8.6
0.22
0.10
0.32
psig
125
3.2
1.4
4.6
barG
10.3
0.14
0.09
0.23
psig
150
2.0
1.3
3.3
Filtration
Notes :
(1)
(2)
(3)
(4)
(7)
(8)
FAD ( Free Air Delivery ) is full package performance including all losses. Tested in accordance with ISO 1217 : 1996 Annex C.
Measured in free field conditions in accordance with PNEUROP/CAGI test codes, with +/- 3 dB(A) tolerance.
40% Relative Humidity Inlet Air
Predicted CAT cell data at rated discharge pressure.
Star Delta Starting Inrush excluding transient spike.
This is a minimum requirement based on 90C wire - It may be necessary to use larger cables to comply with local regulations
or if the voltage drop exceeds 5% of the nominal voltage.
( 10 ) Measured at nominal motor power
( 11 ) Total package including compressor, integral dryer with pre and final compressed air filters
( 12 ) Dew point measured In accordance with ISO 8573-1:2001. With inlet air to package of 25C (77 F) and RH at 60%
( 13 ) Always apply local electrical codes for sizing cables and fusing
psig
200
0.8
1.2
2.0