Design of Bracket

Total load acting on a bracket due to waler beam ( 2WB section )


Section used for waler beam
Self weight of single section of waler beam
Self weight of Combined section of waler beam
fy

=
=
=
=

2UB 610 x 229 x 125.1


125.1 kg /m
250.2 kg /m
2.502 kN/m
250 Mpa

610
1.251

1.251

100
710

Moment = [ ( 1.251 x 0.100 ) +(


= 0.125 + 0.888
= 1.013 kNm/m

1.251 x 0.710 ) ]

Let us provide c/c spacing between bracket as 3.0 m .


Maximum Bending moment for effective length l =
=
=
=
Z requird

1.013 x
3
3.03993 x1000000
3039930 Nmm
3039930
165

18423.82

2 ISA 75 X 75 X 8
Zxx

11

3 m

cm3

For single section

mm3

no of section =

22

cm3
22

For combined section


>

18.42

ok

Provide Bracket @ 3.0 m c/c of spacing .


Check for Bolt Connection
Total force

3039930
1059
=
=

40

2870.567 N
2.8706 kN
1059

Tension per Bolt


=
=

2.8706
2
1.4353

kN
85

Hence Provide 2 Nos HST M20 anchor bolts or equivalent .


Plate Size
According to table 8.2 of IS : 800 - 1984 .
Minimum edge distance for 20 dia bolts is equal to 29 mm .

29

29

75
Provide 250 x 125 x 10 mm thick plate .