You are on page 1of 8

DUPLEX EC4, ECV4

CONTROLLER CP RD

Compact ventilation units


with heat recovery and EC fans
4th generation

Mode
setting,
programming
units
operation

Graphic
display

CP RD controller

Internet
access
Low current cable
connection

RD4 4th
generation
control module
with built-in
web server

Reinforced
thermal
insulation

Exhaust air
EC fan

DUPLEX EC4.D UNIT

Residential ventilation and heating chapter 3. issue 11/2013

Supply air
EC fan
Power supply
230 V
Circular port

By-pass damper
with servo drive

Circular port

Circular port
Circular port

Class G4 / F7 filter

New generation
counter flow heat
recovery exchanger
with efficiency up to 95 %

E S I D E N T I A L

V E N T I L A T I O N

ATREA s.r.o., V Aleji 20


466 01 Jablonec n. N.
Czech Republic

Class G4 / F7 filter

&

H E A T I N G

Phone: +420 608 644 689


Fax: +420 483 368 112
E-mail: expor t@atrea.cz
www.atrea.cz

ATREA VENTILATION SYSTEM


ATREA VENTILATION SYSTEM

System description
The ventilation system provides equal pressure ventilation with heat
recovery for houses and multi-storey apartment blocks, with optional
supply air reheating, pre-cooling in summer and the efficient
utilisation of all internal and external energy gains.
A properly designed ventilation system ensures the supply of fresh
filtered air into each room with occupancy and kitchen, with
thesimultaneous extraction of air from sanitary facilities, toilets,
bathrooms and kitchens.
ATREA offers this system as a full modular set that consists
ofthefollowing main parts:
DUPLEX EC4 and ECV4 series ventilation units with heat recovery
A full measurement and control system that allows controlling
other parts of the system such as zone dampers
and a ground-coupled heat exchanger as well
A comprehensive range of ATREAs HVAC ducts and fittings
suitable for every version required
Application in low-energy and passive houses
In low-energy houses the ventilation system complements their basic
heating system (e.g. central heaters, underfloor heating etc.).
In passive houses in the Czech Republic and Slovakia we recommend
besides the reheating of post-heat recovery air supplied
tothepremises installing an additional heating system to ensure
optimum relative humidity in the rooms is maintained
andoverventilation during heating is thus prevented. They can also
becombined with afireplace insert or another bivalent source.
Whenhigher cooling capacities or heating provided solely via a HVAC
system are required, we recommend selecting units with air
recirculation such as DUPLEX R_4 dual-zone series.

Designing a ventilation system


ATREA has compiled detailed planning documentation
fordesigning a ventilation system that together with component
catalogues and special design software provide planners with all
necessary data for the right design.
Based on long-term measurements and experience with
ventilation systems in residential buildings ATREA recommends
sizing ventilation performances according to EN 15 251
Class2 see the highlighted part of the table below.
Advantages of ventilation systems
Ensure permanent air changes necessary for hygienic
reasons with a possibility of one-off increases (e.g. by an
external signal from toilets, bathrooms, kitchens or other
inputs on the basis of users immediate requirements)
Savings on ventilation costs by up to 90 % thanks to highly
efficient heat recovery exchangers
Elimination of mold formation
Elimination of thermal discomfort due to air supply with
temperature differences kept to a minimum (again as aresult
of heat recovery with high efficiency)
Utilisation of all internal and external thermal gains from the
flat space for the heat recovery pre-heating of ventilation air
The supply of perfectly filtered air (through Class G4 or F7
filters) significantly reduces the occurrence of allergies
andrespiratory diseases
When the unit is set to full performance (via a by-pass),
cooling is possible in summer, particularly through the supply
of night filtered air
A full-range modular system allows for easy or even DIY
installation

Ventilation performances
Ventilation intensity in
unoccupied rooms
(h-1)

Standard regulation
EN 15655 Z1
EN 15251

Minimum value
Recommended value
1st Class
2nd Class
3rd Class

SN 73 0540 2

0,3
0,1 0,2
0,1

Ventilation
intensity
(h-1)
0,3
0,5
0,7
0,6
0,5
0,3 0,6

Volume per
person
(m3/h)
15
25
36
25
15
15 25

Kitchens
(m3/h)

Bathrooms
(m3/h)

Toilets
(m3/h)

100
25
50
50
150
90
72
50
100
72
54
36
50
36
25
References to other regulations

More documentation for designing a ventilation system

Controlled ventilation with


heat recovery

Catalogue of components

www.atrea.cz

CD

Selection software

HEAT RECOVERY WHAT IS IT?

Chilled exhaust
air out
+2 C

Heated fresh
air out
+20 C

Fresh cool air in


0 C
Heat recovery
efficiency
90 %

Warm exhaust
air in
+22 C

Heat recovery principle


Heat transfer occurs through the separating walls of a heat exchanger in winter
warmer exhaust air preheats colder supply air. The same principle is applied also
insummer for cool recovery.
In winter time humidity condensates in exhaust air. This condensate increases heat
recovery efficiency through improved heat transfer and is continuously drained into
asewer system.
Significance of heat recovery
An energy-optimised heat recovery exchanger reaches a highly economical ratio between
power consumption (to run fans), air performance and heat recovery.
The fan input vs. heat recovery gain ratio during ventilation reaches an energy efficiency
of 17 25, i.e. from 1 W of power used to run a DUPLEX EC4 up to 25 W is recovered
from exhaust air. Effective ratio 1 : 25

DUPLEX EC4, ECV4


DESCRIPTION OF DUPLEX EC4, ECV4 UNITS

Intended use
The new, already 4th generation of DUPLEX heat recovery units,
is supplied in two basic ranges: the DUPLEX EC4 under-ceiling
type and the DUPLEX ECV4 vertical type.
The units are intended for the comfort ventilation of all types
ofresidential and civil premises. They are particularly suitable
forlow-energy and passive houses and flats in apartment
buildings with a decentralized ventilation system.
General description
The units housing with efficient 30 mm thick polyurethane
insulation (U = 0,65 Wm-2K-1) and reduced thermal bridging has
a built-in, vortex-type counter-flow heat exchanger made
ofplastic (efficiency up to 95 %), two free wheel type fans with
electronic EC control and optional additional constant air flow
control, G4 supply and exhaust air filters upstream the heat
recovery exchanger, an automatically controlled by-pass damper,
a control module and a connecting terminal board. Condensate
outlets in the doors in the EC4 under-ceiling type are prepared
for both operational directions of the unit. Connecting ports are
of a circular type for flexible or rigid ducts with thermal bridging
reduction. Access to the unit is provided via a hinged door
withsecuring latches.

Advantages of the units


Free wheel, EC type fans built-in as standard are outstanding
fortheir low power input and excellent speed control
Higher performances of the units enable intensive venting bouts
and summer ventilation
A heat recovery efficiency of up to 95 % thanks to the new
generation of heat recovery exchangers
Excellent thermal and insulation parameters of the units housing
with reduced thermal bridging
A by-pass built in as standard, not requiring any additional space;
moreover, due to its design it ensures 100 % by-pass in by-pass
mode without mutual heat transfers
The two standard types of control systems available meet all
user requirements
.Aunits a simpler and cheaper basic control system
.D units a new, optionally installed digital control system
enabling to connect a wide range ofsensors and other inputs,
thecontrol of shut-off and zone ductwork dampers, thecontrol
ofheaters or the houses heating system etc. Inaddition,
itcontains as standard a built-in web server to allow control
viathe Internet
An option to fit built-in electric or external electric or hot-water
based air heaters
An option of the mirror-wise change of the right hand / left hand
side position of EC4 units by simply changing the parameter
inthe control system (.D units) or by simple reconnection (.A units)
Very low height H allowing installation in false ceiling voids

INSTALLATION OF UNITS

DUPLEX ECV4 vertical type


New vertical units DUPLEX ECV4 with nominal performances
190 and390 may be installed, thanks to their width,
intostandard 600 mm wide cabinets see the figure.

min. 10

DUPLEX EC4 under-ceiling type


New DUPLEX EC4 units have a very flat design that allows installing
them into even very low suspended ceilings. The minimum
requirements for suspended ceiling void heights are in the table.
A plasterboard lid is fitted below the unit; in bathrooms the lid must
be airtight and the entire suspended ceiling steam tight.

12

min. 5

DUPLEX EC4

60
inc

l. d

Unit height H
(mm)
280
280
365

Unit
180 EC4
370 EC4
510 EC4

oo

0
60

)
64

r5

EX
PL
4
DU ECV
0
39
0

49

55

ne

(in

Min. ceiling void height X


(mm)
295
295
380

Condensate drainage
During heat recovery heat regaining moisture is
condensated during the cooling of exhaust air. Water
condensates on the walls of the heat recovery exchanger,
further increasing heat recovery efficiency. Condensate runs
out of the heat recovery exchanger in the direction of air being

min 150

HL 21

Inlet into
sewer

min 150

Inlet into
sewer

min 150

min 150

HL 21

extracted and is drained from the DUPLEX unit into a sewer


system. For correct functioning and drainage the unit must be
separated from the sewer system using a siphon of asufficient
height, the recommended minimum being 150 mm.
Small condensation drain pumps may be used.

TECHNICAL DATA DUPLEX EC4


PERFORMANCE PARAMETERS EC4

TECHNICAL DATA EC4

DUPLEX

500
50

400
300

30

70

200

20
W
15
W

100

10
W

0
200
100
150
3
Volume flow rate (m /h)

50

Pressure reserve pst (Pa)

DUPLEX 370 EC4

1000
900
800
700
600
500
400
300
200
100
0

Supply air max. *


Extract air max. *
Max. heat recovery efficiency
Height H
Width S
Length (without ports) L
Diameter of connecting ports
Weight
By-pass
Voltage
Supply air filter class
Condensate drain

m3/h
m3/h
%
mm
mm
mm
mm
kg

mm

180 EC4
180
180
93
280
585
830
160
28

370 EC4 510 EC4


390
510
390
510
95
90
280
365
840
860
1 120
1 290
200
250
32
38
Yes
230 / 50 Hz
G4 (alter. F7)
2x 16 (depending on position)

* Values must be adjusted according to the curves of individual performance graphs

DIMENSIONAL DIAGRAM EC4

UNDER
CEILING TYPE
10
0

14
0

80

60

40

20

18
0

10 W

50

e2

i2
RM

100

150

200 250 300 350 400


Volume flow rate (m3/h)

Pressure reserve pst (Pa)

DUPLEX 180 EC4

e1

1200
1000

60

20

600
400

60

800
12
0

i1

28

80

40

20

200

36

Pressure reserve pst (Pa)

DUPLEX 510 EC4

100

200

400
500
600
300
Volume flow rate (m3/h)

For detailed information and 2D or 3D blocks in DXF use our


selection software.

Legend:
Pressure reserve with filter G4*
Pressure reserve with filter F7*
Power input of the whole unit (both fans incl. controller)
* Max. pressure reserve curve is shown

EC4 VERSION

e2

i2

UNDER
CEILING TYPE

RM

e1

HEAT RECOVERY EFFICIENCY OF EC4

i1
i2

e2
Heat recovery efficiency (%)

RM

100
180 EC4

95

370 EC4

i1

90
510 EC4

85

DUPLEX EC4 units are supplied in a versatile position, i.e. the right hand
and left hand position according to the figure above is selected simply by
changing the parameter in the control system of the unit (.D units) or by
relocating the operating sensor and by reconnecting unit fans (.A units).

80
75

LEGEND
Possible condensation region

Mi = Me

70
0

100

200

300

400
500
600
Volume flow rate (m3/h)

e1

e1
e2
i1
i2
RM

Fresh outdoor air inlet


Fresh filtered air outlet
Exhaust air inlet
Exhaust air outlet
Control module

TECHNICAL DATA DUPLEX ECV4


PERFORMANCE PARAMETERS ECV4

Supply air max. *


Extract air max. *
Max. heat recovery efficiency
Height (without ports) V
Width S
Depth H
Diameter of connecting ports
Weight
By-pass
Voltage
Supply air filter class
Condensate drain

m3/h
m3/h
%
mm
mm
mm
mm
kg

mm

190 ECV4 390 ECV4 520 ECV4


190
390
520
190
390
520
93
90
88
880
950
1 020
560
550
805
370
490
510
125
160
200
26
30
35
Yes
230 / 50 Hz
G4 (alter. F7)
1x 16

DUPLEX 190 ECV4

Pressure reserve pst (Pa)

TECHNICAL DATA ECV4

DUPLEX

550
450

70

350

50
W
40
W

250
150

e2

i2
H

e1
i1

60

S
DUPLEX 390 ECV4

i2
e1

i1

200
250
150
3
Volume flow rate (m /h)

100

DUPLEX 390 ECV4

1000
900
800
700
600
500
400
300
200
100
0

e2

RM

50

Pressure reserve pst (Pa)

DUPLEX 190 ECV4

20
15 W
W
10
W

50
0

* Values must be adjusted according to the curves of individual performance graphs

DIMENSIONAL DIAGRAM OF ECV4 UNITS

10
0

80

60

40

20

14
0

18
0

10 W

50

100

150

200 250 300 350 400


Volume flow rate (m3/h)

S
DUPLEX 520 ECV4

e2

i2
i1

e1

Pressure reserve pst (Pa)

DUPLEX 520 ECV4

1200
1000

20

28

800
12
0

600

80

400
200

40

20

For detailed information and 2D or 3D blocks in DXF use our


selection software.

100

200

300
500
600
400
Volume flow rate (m3/h)

Legend:
ECV4 VERSION

i1 e2

VERTICAL
TYPE

e1 i2

i1

RM

e1 i2

Pressure reserve with filter G4*


Pressure reserve with filter F7*
Power input of the whole unit (both fans incl. controller)
* Max. pressure reserve curve is shown

RM

HEAT RECOVERY EFFICIENCY ECV4

1
K

e2
DUPLEX 190 ECV4
DUPLEX 390 ECV4
DUPLEX 520 ECV4

LEGEND

e1
e2
i1
i2
RM

Fresh outdoor air inlet


Fresh filtered air outlet
Exhaust air inlet
Exhaust air outlet
Control module

DUPLEX 390 ECV4


DUPLEX 520 ECV4

Heat recovery efficiency (%)

100
190 ECV
4

95
90

390 ECV4 520 EC


V4

85
80
75

Possible condensation region

Mi = Me

70
0

100

200

300

400
500
600
Volume flow rate (m3/h)

CONTROL SYSTEM
CONTROL SYSTEMS GENERAL OVERVIEW
External inputs bathrooms, WC
Control of external elements
Constant
Internet
Performance
Ground
air flow By-pass connection Delay and Immediate
Reheater and HP Heating 2 CH 2 zones Kitchen
HVAC
Input Shut-off
setting range
coupled
control
(webserver) run-down
start
preheater perf. system circuits dampers damper programming
010 V dampers
exchanger
1
EC4.A
10 100 %
Manual
1
1+2 (delay)
EC4.A+RA4-E
l
l
Control
system type

EC4.D
EC4.D.CF

10 100 %

Auto
control

DUPLEX EC4.A ANALOG CONTROL SYSTEM

The simplified control system is a choice for undemanding systems


requiring only the basic functions of measurement and control.
The unit is controlled by the CP 04 RA controller with a mechanical knob
for performance control. It allows connecting one 230 V external signal
for one-off ventilation performance increases (e.g. a signal from atoilet
or bathroom) and one 010 V input for performance control (e.g. signal
from CO2 sensor or relative humidity sensor).
Optionally the system can be additionaly equiped with
230 V

the RA4-E expansion module to include a24 V DC power supply


for sensors, shut-off damper control (24 V DC), two230V
external inputs to increase performance (withadjustable delay
stop), thecontrol of integrated EDO electric reheater
orexternal EPO-V electric preheater. Thecontrol of hot-water
based reheaters or electric preheaters is not possible.

Connection to main power 230 V / 50 Hz

Optional inputs and outputs

movable power input with plug (3 m length, included)

CP 04 RA
controller connection
(3 m length, included)

DUPLEX
EC4.A
ECV4.A

SYKFY 5x2x0,5 (max. 25 m)

DUPLEX EC4.D DIGITAL CONTROL SYSTEM

General description
The RD4 digital control module represents the most modern method
ofcontrolling the unit. It provides all basic functions and at the same time
contains a range of inputs and outputs to connect with optional sensors
such as those of CO2 and relative humidity, signals from rooms (toilets,
bathrooms, kitchens), heating systems including shut-off valves
orshut-off dampers in ducts.
Additionally it contains a web-server and the option of Internet access.
The unit with the digital module may be controlled:
a) By the CP 18 RD or CP 19 RD series controller with graphic display
b) Without a controller, only via 010 V voltage (e.g. from a CO2 sensor
or through a higher-ranking system). Control via external signals
and other automatic ventilation functions remain.
c) Via a built-in intelligent web-server that allows control and setting
viaa web application and can also be used for versions a) and b).
d) By an external control system via a standard Modbus TCP interface.
Functions
The control module provides all basic functions of the unit:
Programming various ventilation performances for the day and week
Continuous control of both fans, with a constant performance function
in the CF version (i.e. an automatic change of the performance level
toreach the desired flow rate directly in m3/h)
Automatic control of the by-pass damper (supply air by-passing)
according to outdoor air temperature
Electric heater (an optional extra) control for constant supply air
temperature within a range of 15 to 50 C (maximum temperature
depends on the capacity of the electric heater installed) or air
temperature control according to a programmed temperature
differential against required interior temperature (may be changed
automatically according to settings during a day)
Hot-water based heater (an optional extra) switching, setting supply air
temperature by controlling the mixing manifold or the heating water
choke valve via a 0 10 V signal, including the anti-freeze protection
ofthe hot-water based heater (by ADS 120 sensor)

Anti-freeze protection of the heat recovery exchanger


Switching to a required performance level when started via
an external signal (e.g. from the toilet, bathroom, kitchen)
with programmable start and run-down
Supply and extraction shut-off damper control, and the control
of two zone ventilation dampers and a kitchen extraction
damper (the dampers are not included) 24 V DC
An automatic operation option according to sensors
CO2 concentration, relative humidity or VOC (optional extras)
a 010 V signal or a switch contact
Depending on settings the unit enables a periodic venting
mode the unit is idle and switches ventilation on at set
intervals
Automatic ventilation time settings depending on occupancy
and the air-tightness of the building during periodic
ventilation or when burst ventilation is started
CP RD series controllers
They are intended for setting basic ventilation modes
anddisplaying the status of the ventilation unit including failure
conditions. It allows the user to access standard functions
orprogram operating modes that can be run manually
orautomatically according to weekly program settings.
Thecontroller also enables to set a temporary party / holiday
mode and includes an integrated room thermostat with
aweekly heating / cooling mode that can control a simple
heating system using the control module functions.
All data are shown on a well-arranged graphic display. Settings
and control are done via a rotary knob.
CP 18 RD

Connection to main power 230 V / 50 Hz

230 V

ADS 100 ABB

CP 19 RD

Optional inputs and outputs

via stand-alone 10 A circuit protection, char. B


(not included)

CP 18 RD
CP 19 RD
Connection to controller
(not included)
3 x 0,5 mm2 (shielded)
e.g. SYKFY 2x2x0,5

DUPLEX
EC4.D
ECV4.D

Modbus TCP
Ethernet
RJ45 plug

Internet

OPTIONAL ACCESSORIES

ELECTRIC HEATERS EPO-V

Permitted terminal board positions

Includes two protection thermostats


areversible one (60 C) and a safety
irreversible one (switches off at 120 C)
Contains an interference-free SSR relay
asstandard
The safety thermostat reset button
onthehousing during installation access
totheheater must be taken into account,
donot install with the lid pointing downward
Minimum air velocity in the heater is 1.5m/s
Protection class IP 43, can be used only
innormal environments

Used as preheater to preheat fresh air, to be


installed in ducts on fresh air inlet can be
used with analog and digital control system
Used as afterheater to reheat supply air, to be
installed in ducts after the unit can be used
only with digital control system (ADS 120
sensor required to be installed in theduct
downstream the heater)
Galvanized sheet metal housing
Housing includes a terminal board
and internal wiring
Stainless steel heating rods

EPO-V 160/1,5

1,5

230

Permitted flow direction

EPO-V 200/2,1

2,1

EPO-V 250/3,0

3,0

125

190 ECV4

110*

160

180 EC4, 390 ECV4

230

170*

200

370 EC4, 520 ECV4

400

260*

250

510 EC4

30
20
10

0
20
O-V
P
E
50
-V 2
EPO

* If requested lower flowrate than shown here, please use the built-in
EDO integrated heaters.

Recommended
for DUPLEX

EP
O-V
12
5
EP
OV
16
0

EPO-V 125/0,9

D
(mm)

p (Pa)

PRESSURE LOSS
Min. air
Voltage
flowrate
(V)
(m3/h)
45*
230

Power
input
(kW)
0,9

Type

100 200 300 400 500


Air volume (m3/h)

BUILT-IN ELECTRIC REHEATER EDO

To be integrated in the unit, installation


atapredetermined place inside the unit
Operating temperature control is provided by
thecontrol system of the unit (theanalog control
system must be completed with an expansion
module RA4-E)
Ready for easy installation in the unit incl. cables
Includes an interference-free SSR relay (for digital
control system types EDO4-D) or an switching
relay (analog control system types EDO4-A)
Voltage
(V)
230
230
230

Power input
(W)
200
500
750

Type
EDO4 - 0,2 (A, D)
EDO4 - 0,5 (A, D)
EDO4 - 0,8 (A, D)

Max. exhaust air temperature depends


onEDO performance (e.g. the power input
of 100 W increases supply air temperature
inthe volume of 100 m3/h by max. 3 C)
The integration of the EDO directly
intheunit does not reduce the units
pressurereserve
Contains two safety reversible
thermostats 45 C and 60 C

Heating tube length


(mm)
118
118
189

Min. air flow rate


(m3/h)
45
75
95

Recommended for DUPLEX


180, 370 EC4, 190, 390 ECV4
370, 510 EC4, 390, 520 ECV4
510 EC4, 520 ECV4

HOT WATER AIR HEATERS TPO EC THV

Used to reheat air, to be installed in ducts


(can be used only with digital control system)
ADS 120 sensor required (to be installed
intheduct downstream the heater)
Galvanized sheet metal housing
Aluminium lamellas on copper tubes

0,3
0,5
0,8
1,3
1,9
2,5

* The table applies for heating water temperature 55 / 35 C, supply air


after heat recovery 15 20 C, exhaust air min. 30 C. Parameters for
different conditions can be found using the ATREA selection software.

PRESSURE LOSS
50
40
30

Type

D
(mm)

B
(mm)

H
(mm)

L
(mm)

H
()

L1
(mm)

Recommended
for DUPLEX

TPO 125 EC THV


TPO 160 EC THV
TPO 200 EC THV
TPO 250 EC THV

125
160
200
250

380
380
380
380

300
300
300
300

485
485
485
485

1/2
1/2
1/2
1/2

50
50
50
50

190 ECV4
180 EC4, 390 ECV4
370 EC4, 520 ECV4
510 EC4

TP
O1
6
T
PO 0
TP
O
25 200
0

Heating power*
(kW)

125

L1

Pressure
loss
(kPa)
0,1
0,2
0,3
0,6
0,9
1,3

TPO

100
150
200
300
400
500

Water flow
rate
(l/h)
30
40
60
80
100
120

p (Pa)

Air flow rate


(m3/h)

Maximum operating pressure 10 bar


Maximum operating temperature 100 C
As standard the heater includes electric
choke valve with 24 V DC power supply
and 0 10 V control

20
10
0

100 200 300 400 500


Air volume (m3/h)

MODULAR ATREA HVAC SYSTEM


DUPLEX EC4, ECV4 UNITS

CONTROLLERS

DUPLEX 180 EC4.D

Ord. No. A160410

Controller CP 18 RD

DUPLEX 180 EC4.D.CF

Ord. No. A160420

white color

DUPLEX 180 EC4.A

Ord. No. A160400

Controller CP 18 RD

DUPLEX 370 EC4.D

Ord. No. A160411

ivory color

DUPLEX 370 EC4.D.CF

Ord. No. A160421

Controller CP 19 RD

DUPLEX 370 EC4.A

Ord. No. A160401

white color

DUPLEX 510 EC4.D

Ord. No. A160412

Controller CP 04 RA

DUPLEX 510 EC4.D.CF

Ord. No. A160422

white color

DUPLEX 510 EC4.A

Ord. No. A160402

DUPLEX 190/0 ECV4.D

Ord. No. A160413

DUPLEX 190/0 ECV4.D.CF

Ord. No. A160423

DUPLEX 190/0 ECV4.A

Ord. No. A160403

DUPLEX 390/0 ECV4.D

Ord. No. A160414

Ord. No. A170283

Ord. No. A170284

Ord. No. A170282

standard part
of.A units

EXPANSION MODULE ANALOG CONTROL

RA4-E
Expansion module

Ord. No. A170291

DUPLEX 390/1 ECV4.D

Ord. No. A160416

DUPLEX 390/0 ECV4.D.CF

Ord. No. A160424

EPO-V 125/0,9

Ord. No. A150101

DUPLEX 390/1 ECV4.D.CF

Ord. No. A160426

EPO-V 160/1,5

Ord. No. A150102

DUPLEX 390/0 ECV4.A

Ord. No. A160404

EPO-V 200/2,1

Ord. No. A150103

DUPLEX 390/1 ECV4.A

Ord. No. A160406

EPO-V 250/3,0

Ord. No. A150105

DUPLEX 520/0 ECV4.D

Ord. No. A160415

TPO 125 EC THV

Ord. No. A160212

DUPLEX 520/1 ECV4.D

Ord. No. A160417

TPO 160 EC THV

Ord. No. A160213

DUPLEX 520/0 ECV4.D.CF

Ord. No. A160425

TPO 200 EC THV

Ord. No. A160214

DUPLEX 520/1 ECV4.D.CF

Ord. No. A160427


Ord. No. A160405

TPO 250 EC THV


ADS 120

Ord. No. A160215

DUPLEX 520/0 ECV4.A

Ord. No. A160407

ADS 120 sensor required for


EPO-V or TPO EC THV heaters

Ord. No. A142203

DUPLEX 520/1 ECV4.A

SPARE FILTER CASSETTES

OPTIONAL ACCESSORIES AIR HEATERS

OPTIONAL ACCESSORIES AIR REHEATERS

FK 180 EC4, 190 ECV4 - G4 Ord. No. A160920

EDO4 - 0,2 - D

FK 180 EC4, 190 ECV4 - F7 Ord. No. A160925

EDO4 - 0,5 - D

Ord. No. A160451

FK 370 EC4 - G4

Ord. No. A160921

EDO4 - 0,8 - D

Ord. No. A160452

FK 370 EC4 - F7

Ord. No. A160926

EDO4 - 0,2 - A

Ord. No. A160460

FK 510 EC4 - G4

Ord. No. A160923

EDO4 - 0,5 - A

Ord. No. A160461

EDO4 - 0,8 - A

Ord. No. A160462

FK 510 EC4 - F7

Ord. No. A160928

FK 390 ECV4 - G4

Ord. No. A160922

FK 390 ECV4 - F7

Ord. No. A160927

FK 520 ECV4 - G4

Ord. No. A160924

FK 520 ECV4 - F7

Ord. No. A160929

Ord. No. A160450

OPTION AL ACCESSORIES DIGITAL INPUT 0 10 V

ADS RH 24
relative humidity room sensor

Ord. No. A142318

Spare air filters are delivered in package of 1 pc.


ADS SMOKE 24
cigarette smoke and air quality Ord. No. A142311
room sensor

SPARE FILTER CLOTHS

FT 180 EC4, 190 ECV4 - G4 Ord. No. A160950

ADS C02 24

FT 370 EC4 - G4

Ord. No. A160951

room sensor for smooth


ventilation performance control
according to current CO2 levels

FT 370 EC4 - F7

Ord. No. A160955

ADS C02 D

FT 510 EC4 - G4

Ord. No. A160952

FT 510 EC4 - F7

Ord. No. A160956

FT 390 ECV4 - G4

Ord. No. A160958

FT 390 ECV4 - F7

Ord. No. A160959

FT 520 ECV4 - G4

Ord. No. A160953

FT 520 ECV4 - F7

Ord. No. A160957

FT 180 EC4, 190 ECV4 - F7 Ord. No. A160954

Ord. No. A142319

duct sensor for smooth


Ord. No. A142330
ventilation performance control
according to current CO2 levels

EE16 F3B51
relative humidity duct sensor

Ord. No. A142314

OPTIONAL ACCESSORIES CONTACT INPUT

Spare filter cassettes are delivered in package of 10 pcs,


i.e. 5 replacements.
Carbon filter cloth to reduce odours in supply air available. Contact
your supplier for information on options.

HYG 6001
Room hygrostat relative
humidity sensor

Ord. No. A142303