The 162 Power and Distribution System supplies 100 to 2000 Amps of +24VDC power in increments of 100 Amps.
The system is self-contained, providing power, distribution, alarms, and monitoring within one bay. To create the
flexible power needed by the 162, up to twenty switchmode rectifiers can be used. Up to eight optional +24VDC
to -48VDC converters can be installed, for a total output current of 80 Amps at -48VDC. The 162 was designed
for ease of installation, incorporating all customer connections for loads, controls, alarms, and monitoring from the
front of the bay.
Users may choose one of four distribution options for +24VDC, and one of two options for -48VDC. All +24VDC
distribution options feature A & B sections. The 162 system may be accessed, monitored, and controlled from
one entry point via the meter, monitor, and control (MMC) panel, which is easy to use and provided as standard
equipment.
The system is equipped with eight relays for extending alarms and status remotely, and 22 LEDs for immediate
visual notification of alarms and operating status. A & B low voltage load disconnects (LVLD) are optional.
162/1-03/a
Specifications are subject to change without notice. Please visit our website for the latest revision.
Output
Float Voltage Range
Current
Environmental
Storage Ambient
Operating Ambient (NEBS)
Humidity
Mechanical
Height
Width
Depth
Weight
Mounting
Cooling
Documentation
Product Manual
System Layout Drawing
4380211PD
J-438162P
Visual Indicators
MMC Front Panel:
LED Description
Power Major
Power Minor
Rectifier Major
Rectifier Minor
Battery Monitor
Distribution Fuse
Distribution Current
MMC OK
Low Low Voltage
Low Voltage
High Voltage
Color
Red
Amber
Red
Amber
Amber
Red
Amber
Green
Red
Amber
Red
LED Description
Battery Fuse
Battery Distribution
Battery Discharge
Load Disconnect
Total Current
AC Fail
Temp High/Low
Float Mode
Equalize Mode
BTC Active
Color
Red
Red
Amber
Red
Amber
Amber
Amber
Green
Amber
Amber
Specifications are subject to change without notice. Please visit our website for the latest revision.
162/1-03/a
Options
List #
1
5
6
7
8
20
22
25
27
30
31
32
33
40
41
Description
PECO II Part Number
Basic +24VDC @ 2,000 Amp bay including frame, controller,
distribution bus bar and rectifier shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6070836P
OPTION 1: (80) 2-100 Amp plug-in circuit breaker positions, including output terminator
bus & ground return bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180602P
OPTION 2: (24) 2-100 Amp, (5) 125 - 250 Amp, (4) 300 - 450 Amp circuit breaker positions
including output termination bus bar & ground return bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180603P
OPTION 3: (48) 2 - 100 Amp, (6) 125 - 250 Amp circuit breaker positions
including output termination bus bar & ground return bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180606P
OPTION 4: (36) 2 - 100 Amp, (8) 125 - 250 Amp circuit breaker positions
including output termination bus bar & ground return bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180608P
+24 VDC @ 100 Amp rectifier module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SM100F24-UP
Rectifier blank for unused rectifier positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4361154P
-48 VDC @ 10 Amp DC/DC converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SM48P10A-D
DC/DC converter blank for unused converter positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4361159P
-48 VDC @ 40 Amp initial converter plant consisting of (1) 40 Amp converter shelf and wiring,
add up to (4) list 25 converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420552P
-48 VDC @ 40 Amp supplemental converter plant consisting of
(1) 40 Amp converter shelf and wiring, add up to (4) list 25 converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420552P-1
Converter distribution: (3) 2 - 60A circuit breaker positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420556P
Converter distribution: (20) 0.18 - 7.5A GMT fuse positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420556P-1
Load A/B disconnects for +24VDC distribution options, list 5-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420554P
Load C disconnect for -48VDC DC/DC converter plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6420553P
Bolt-on Type
Description
PECO II Part Number
125 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050116P-125
150 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050116P-150
175 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050116P-175
200 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050116P-200
225 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050116P-225
250 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050116P-250
300 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050115P-300
350 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050115P-350
400 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050115P-400
450 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3050115P-450
Specifications are subject to change without notice. Please visit our website for the latest revision.
Line Drawing
162 Power System is shown
Option 1
Option 2
Option 3
Option 4
Certifications:
Specifications are subject to change without notice. Please visit our website for the latest revision.
162/1-03/a