You are on page 1of 3

AIR HANDLERS

CBX32MV

DAVE LENNOX SIGNATURE COLLECTION


R-410A Ready - Multi-Position - Variable Speed

P R O D U C T S P E C I F I C AT I O N S

Bulletin No. 210352


October 2012
Supersedes July 2012

Nominal Capacity - 1.5 to 5+ Tons


Optional Electric Heat - 2.5 to 25 kW
MODEL NUMBER IDENTIFICATION

CB X 32 mV - 036 - 230 - 6 - 01
Minor Revision Number

Unit Type
CB = Air Handler
Refrigerant Type
X = R-410A
Series
Configuration
MV = Multi-Position, Variable
Speed Blower Motor
Nominal Cooling Capacity - Tons
018/024 = 1.5 to 2 tons
024/030 = 2 to 2.5 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
068 = 5+ tons

Refrigerant Metering Device


2 = Fixed Orifice
3 = TXV - Bleedport (indoor unit)
4 = TXV - Non-bleedport (indoor unit)
5 = TXV - Non-bleedport (outdoor unit)
6 = TXV - R-410A Non-bleedport (indoor unit)

Voltage
230 = 208/230V-60hz-1ph

SPECIFICATIONS
General Data

Model Number

Connections
in.

CBX32MV-018/024

CBX32MV-024/030

CBX32MV-036

Nominal tonnage

1.5 to 2

2 to 2.5

Refrigerant

R-410A

R-410A

R-410A

Suction / vapor (o.d.) line - sweat

5/8

3/4

3/4

Liquid line (o.d.) - sweat

3/8

3/8

3/8

Condensate drain - in. (fpt)


Indoor
Coil

(2) 3/4

(2) 3/4

(2) 3/4

Net face area - ft.2

3.56

4.44

5.0

Tube outside diameter - in.

3/8

3/8

3/8

Number of rows

Fins per inch

12

12

12

10 x 7

10 x 8

10 x 8

1/2

1/2

1/2

(1) 15 x 20 x 1

(1) 20 x 20 x 1

(1) 20 x 20 x 1

126

152

183

208/230V-1ph

208/230V-1ph

208/230V-1ph

Maximum overcurrent protection (unit only)

15

15

15

Minimum circuit ampacity (unit only)

88W58

88W58

88W58

Blower Data

Wheel nominal diameter x width - in.


Motor output - hp

Filters

Number and size - in.

Shipping Data - 1 Package - lbs.

ELECTRICAL DATA
Voltage - phase - 60hz
2

CONTROLS
icomfort Wi-Fi Thermostat
4

Remote Outdoor Sensor (for dual fuel and Humiditrol )

X2658

X2658

X2658

Discharge Temperature Sensor

88K38

88K38

88K38

Y0349

Y0349

Y0349

X2658

X2658

X2658

82W01

82W01

44K15

44K15

ComfortSense 7000 Thermostat


Remote Outdoor Sensor (for dual fuel and Humiditrol )

OPTIONAL ACCESSORIES - order separately


Circuit Breaker Cover Kit

82W01

Downflow Combustible Flooring Base

34J72

Electric Heat

See Electric Heat Data tables

Healthy Climate
Germicidal Light

UVC-24V (24V)

X9423

X9423

X9423

Shielding Baffle (required)

Y5172

Y5172

Y5172

UVC-41W-S (110/230v-1 ph)

X9424

X9424

X9424

Shielding Baffle (required)

Y5171

Y5171

Y5171

Horizontal Support Frame Kit

56J18

56J18

56J18

Hot Water Heat Kit

90W84

90W84

90W84

Side Return Unit Stand (Upflow)

45K31

45K32

45K32

Single-Point Power Source Control Box

21H39

21H39

21H39

Wall Hanging Bracket Kit (Upflow)

45K30

45K30

45K30

Disposable frame type filter.


2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167F.
4
Remote Outdoor Sensor may be used with an icomfort-enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional outdoor unit.
5
Optional for EvenHeater electric heat operation and service diagnostics.
1

INSTALLATION CLEARANCES WITH ELECTRIC HEAT


Cabinet

0 inch (0 mm)

To Plenum

1 inch (25 mm)

To Outlet Duct within 3 feet (914 mm)

1 inch (25 mm)

Floor

See Note #1

Service / Maintenance

See Note #2

Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible
flooring base.
2
Front service access - 24 inches (610 mm) minimum.
NOTE - If cabinet depth is more than 24 inches (610 mm), allow a minimum of the cabinet depth plus 2 inches (51 mm).

CBX32MV / Page 7

SPECIFICATIONS
General Data

Model Number
Nominal tonnage
Refrigerant
Connections
Suction / vapor (o.d.) line - sweat
in.
Liquid line (o.d.) - sweat
Condensate drain - in. (fpt)
Indoor
Net face area - ft.2
Coil
Tube outside diameter - in.
Number of rows
Fins per inch
Blower Data
Wheel nominal diameter x width - in.
Motor output - hp
1
Filters
Number and size - in.
Shipping Data - 1 Package - lbs.

CBX32MV-048
4
R-410A
7/8
3/8
(2) 3/4
7.22
3/8
3
12
12 x 9
1
(1) 20 x 24 x 1
212

CBX32MV-060
5
R-410A
7/8
3/8
(2) 3/4
7.22
3/8
3
12
12 x 9
1
(1) 20 x 24 x 1
212

CBX32MV-068
5+
R-410A
1-1/8
3/8
(2) 3/4
7.77
3/8
3
12
15 x 9
1
(1) 20 x 25 x 1
244

208/230V-1ph
20
11

208/230V-1ph
20
11

208/230V-1ph
20
11

49W95
X2658
88K38
Y0349
X2658

49W95
X2658
88K38
Y0349
X2658

49W95
X2658
88K38
Y0349
X2658

82W01
44K15
See Electric Heat Data tables
X9423
Y5172
X9424
Y5171
56J18
90W84
45K32
21H39
45K30

82W01
44K15

ELECTRICAL DATA
2

Voltage - phase - 60hz


Maximum overcurrent protection (unit only)
3
Minimum circuit ampacity (unit only)

CONTROLS
icomfort Touch Communicating Thermostat
4
Remote Outdoor Sensor (for dual fuel and Humiditrol)
5
Discharge Temperature Sensor
ComfortSense 7000 Thermostat
Remote Outdoor Sensor (for dual fuel and Humiditrol)

OPTIONAL ACCESSORIES - order separately


Circuit Breaker Cover Kit
Downflow Additive Base
Electric Heat
Healthy Climate
Germicidal Light

82W01
44K15
UVC-24V (24V)
Shielding Baffle (required)
UVC-41W-S (110/230v-1 ph)
Shielding Baffle (required)

Horizontal Support Frame Kit


Hot Water Heat Kit
Side Return Unit Stand (Upflow)
Single-Point Power Source Control Box
Wall Hanging Bracket Kit (Upflow)

X9423
Y5172
X9424
Y5171
56J18
90W84
45K32
21H39
45K30

X9423
Y5172
X9424
Y5171
N/A
90W84
N/A
21H39
45K30

Disposable frame type filter.


HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167F.
4
Remote Outdoor Sensor may be used with an icomfort-enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional outdoor unit.
5
Optional for EvenHeater electric heat operation and service diagnostics.
1
2

REPLACEMENT CIRCUIT BREAKERS


Voltage
208/240V - 1 Phase

208/240V - 3 Phase

CBX32MV / Page 8

Description
25 amp, 2 pole
30 amp, 2 pole
35 amp, 2 pole
40 amp, 2 pole
45 amp, 2 pole
50 amp, 2 pole
60 amp, 2 pole
30 amp, 3 pole
35 amp, 3 pole
40 amp, 3 pole
45 amp, 3 pole
50 amp, 3 pole
60 amp, 3 pole

Catalog No.
41K13
17K70
72K07
49K14
17K71
41K12
17K72
64W47
41K14
41K16
18M86
41K15
41K17

You might also like